B09_Amendment_0006.pdf
PDF 168 KB Posted
- Attached to
- Replace Failing Wawona Campground Restroom Leachfields with Connection to Wawona YOSE 197065
- Solicitation number
- 140P2019R0073
About this file
Amendment 0006
View the file
Other files
Show all 15
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
(x)
140P2019R0073 x x
1 copies of the amendment; (b) By acknowledging receipt of this amendment on each copy of the offer submitted ; or (c) By separate letter or telegram which includes a reference to the solicitation and amendment numbers. FAILURE OF YOUR ACKNOWLEDGEMENT TO BE RECEIVED AT
THE PLACE DESIGNATED FOR THE RECEIPT OF OFFERS PRIOR TO THE HOUR AND DATE SPECIFIED MAY RESULT IN REJECTION OF YOUR OFFER. If by virtue of this amendment you desire to change an offer already submitted , such change may be made by telegram or letter, provided each telegram or letter makes reference to the solicitation and this amendment, and is received prior to the opening hour and date specified.
x
DSC
Denver CO 80225-0287 P.O. Box 25287 12795 W. Alameda Pkwy DOI, NPS, DSC Contracting Services
PDS
Denver CO 80225-0287 P.O. Box 25287 12795 W. Alameda Pkwy NPS, DSC Contracting Services Div
YOSE 19706508/25/20190006
13. THIS ITEM ONLY APPLIES TO MODIFICATION OF CONTRACTS/ORDERS. IT MODIFIES THE CONTRACT/ORDER NO. AS DESCRIBED IN ITEM 14.
12. ACCOUNTING AND APPROPRIATION DATA (If required) is not extended.is extended, Items 8 and 15, and returning
Offers must acknowledge receipt of this amendment prior to the hour and date specified in the solicitation or as amended , by one of the following methods: (a) By completing
The above numbered solicitation is amended as set forth in Item 14. The hour and date specified for receipt of Offers
11. THIS ITEM ONLY APPLIES TO AMENDMENTS OF SOLICITATIONS
FACILITY CODE CODE
10B. DATED (SEE ITEM 13)
10A. MODIFICATION OF CONTRACT/ORDER NO.
9B. DATED (SEE ITEM 11)
9A. AMENDMENT OF SOLICITATION NO.
CODE
8. NAME AND ADDRESS OF CONTRACTOR (No., street, county, State and ZIP Code)
7. ADMINISTERED BY (If other than Item 6)CODE 6. ISSUED BY
PAGE OF PAGES
4. REQUISITION/PURCHASE REQ. NO.3. EFFECTIVE DATE2. AMENDMENT/MODIFICATION NO. 5. PROJECT NO. (If applicable)
1. CONTRACT ID CODE
AMENDMENT OF SOLICITATION/MODIFICATION OF CONTRACT
07/23/2019
CHECK ONE A. THIS CHANGE ORDER IS ISSUED PURSUANT TO: (Specify authority) THE CHANGES SET FORTH IN ITEM 14 ARE MADE IN THE CONTRACT
B. THE ABOVE NUMBERED CONTRACT/ORDER IS MODIFIED TO REFLECT THE ADMINISTRATIVE CHANGES (such as changes in paying office, C. THIS SUPPLEMENTAL AGREEMENT IS ENTERED INTO PURSUANT TO AUTHORITY OF:
D. OTHER (Specify type of modification and authority) appropriation date, etc.) SET FORTH IN ITEM 14, PURSUANT TO THE AUTHORITY OF FAR 43.103(b).
E. IMPORTANT: Contractor is not, is required to sign this document and return __________________ copies to the issuing office.
ORDER NO. IN ITEM 10A.
14. DESCRIPTION OF AMENDMENT/MODIFICATION (Organized by UCF section headings, including solicitation/contract subject matter where feasible.)
The purpose of the amendment is to provide the fiber cut sheet.
Legacy Doc #: NPS
Period of Performance: 10/01/2019 to 05/31/2020
16A. NAME AND TITLE OF CONTRACTING OFFICER (Type or print)15A. NAME AND TITLE OF SIGNER (Type or print)
15C. DATE SIGNED 16B. UNITED STATES OF AMERICA 15B. CONTRACTOR/OFFEROR 16C. DATE SIGNED
(Signature of person authorized to sign) (Signature of Contracting Officer)
Todd Stackhouse
STANDARD FORM 30 (REV. 10-83)
Prescribed by GSA
FAR (48 CFR) 53.243
NSN 7540-01-152-8070
Previous edition unusable
Except as provided herein, all terms and conditions of the document referenced in Item 9 A or 10A, as heretofore changed, remains unchanged and in full force and effect .
Outside Plant Cables Fiber Optic
Product Construction:
Fiber:
• 2–312 fibers
• Loose tube gel-filled
• Color-coding per TIA/EIA 598 B Central Strength Member:
• Epoxy/glass rod Jacket:
• Black UV- and moisture-resistant polyethylene (PE)
• Sequential footage markings*
Features:
• Loose tube gel-filled construction for superior fiber protection
• UV- and moisture-resistant design
• Dry Water Block cable core for ease of handling Performance:
• Temperature:
Storage -40˚C (-40˚F) to +75˚C (+167˚F) Installation -30˚C (-22˚F) to +60˚C (+140˚F) Operating -40˚C (-40˚F) to +70˚C (+158˚F)
• Minimum Bend Radius:
20 X OD—Installation 10 X OD —In-Service
• Maximum Crush Resistance:
Short - 125 lbs/in (220 N/cm) Long - 63 lbs/in (110 N/cm)
Applications:
• Interbuilding voice or data communication backbones
• Installed in ducts, underground conduit or aerial/lashed Compliances:
• Tested in accordance with EIA/TIA-455 FOTPs
• ICEA S-87-640
• Rural Utilities Service (RUS) 7 CFR
1755.900 (REA PE-90)
• GR-20
• RoHS Compliant Directive 2002/95/EC
Options:
• Gel-free tube versions also available, use
“-DT” suffix (XX0124M1A-DT)
• Alternate 6-fiber per tube available upon request
* Sequential meter markings available upon request
Loose Tube Single Jacket Cable
EIA/TIA 455
Ordering Part Number Example
AQ0124M1A-DWB
Singlemode, 12 fibers, loose tube SJ Please see pages 4 and 5 for a complete guide on part number selection and ordering information.
Hybrid designs (containing singlemode and multimode fiber) and composite designs (containing copper conductors) are also available.
For complete listing of all fiber counts offered, please contact your General Cable sales representative.
Factory-installed eyelet option for quick cable-pull setups available.
Typical Cross-Section Ripcord
Outer Jacket
Overall Strength Member
Water Blocking Tape
Gel-Filled Buffer Tube
Central Strength Member
Filler
Ripcord48 Fiber
CATALOG
NUMBER
FIBER
COUNT
NO. OF
LOOSE
TUBES
NO. OF
FILLERS
NOMINAL CABLE
DIAMETER
NOMINAL CABLE
WEIGHT
MAXIMUM TENSILE LOAD
SUB-UNIT CABLE
IN mm LBS/1000' kg/km LBS N LBS N
XX0023M1A-DWB 2 2 3 0.44 11.1 55 82 600 2700 180 800
XX0044M1A-DWB 4 1 4 0.44 11.1 55 82 600 2700 180 800
XX0064M1A-DWB 6 1 4 0.44 11.1 55 82 600 2700 180 800
XX0084M1A-DWB 8 1 4 0.44 11.1 55 82 600 2700 180 800
XX0124M1A-DWB 12 1 4 0.44 11.1 55 82 600 2700 180 800
XX0184M1A-DWB 18 2 3 0.44 11.1 55 82 600 2700 180 800
XX0244M1A-DWB 24 2 3 0.44 11.1 55 82 600 2700 180 800
XX0364M1A-DWB 36 3 2 0.44 11.1 55 82 600 2700 180 800
XX0484M1A-DWB 48 4 1 0.44 11.1 55 82 600 2700 180 800
XX0604M1A-DWB 60 5 0 0.44 11.1 55 82 600 2700 180 800
XX0724M1A-DWB 72 6 0 0.47 12.0 66 98 600 2700 180 800
XX0964M1A-DWB 96 8 0 0.54 13.7 84 125 600 2700 180 800
XX1204M1A-DWB 120 10 0 0.61 15.4 106 158 600 2700 180 800
XX1444M1A-DWB 144 12 0 0.68 17.3 132 197 600 2700 180 800
XX1924M1A-DWB 192 16 2 0.69 17.6 128 191 600 2700 180 800
XX2164M1A-DWB 216 18 0 0.69 17.6 128 191 600 2700 180 800
XX2404M1A-DWB 240 20 2 0.75 19.0 153 228 600 2700 180 800
XX2644M1A-DWB 264 22 0 0.75 19.0 153 228 600 2700 180 800
XX2884M1A-DWB 288 24 0 0.79 20.0 171 255 600 2700 180 800
XX3124M1A-DWB 312 26 0 0.84 21.3 191 285 600 2700 180 800
XX denotes glass type.
A complete listing of NextGen® Brand glass types is specified on page 3 of this catalog.
XX0124M1A-DWB 12 1 4 0.44 11.1 55 82 600 2700 180 800
SM0124M1A-DWB
File details come from the government source that posted it.