GRCA_160057_-_C305.pdf

PDF 205 KB Posted

Attached to
Replace North Rim Potable Water Distribution System at Grand Canyon National Park
Solicitation number
140P2018R0076
Issued by

About this file

Drawing Sheet C305

View the file

Other files

Show all 18

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

AutoCAD SHX Text

LINK SEAL DETAIL

AutoCAD SHX Text

NO SCALE

AutoCAD SHX Text

NON-FREEZE YARD HYDRANT DETAIL

AutoCAD SHX Text

NO SCALE

AutoCAD SHX Text

CAST IRON LIFT HANDLE

AutoCAD SHX Text

HEAVY DUTY CAST IRON HEAD CASTING

AutoCAD SHX Text

3/4" MALE HOSE CONNECTION

AutoCAD SHX Text

1" GALVANIZED STEEL CASING

AutoCAD SHX Text

INLET CONNECTION (1" FNPT)

AutoCAD SHX Text

GRADE

AutoCAD SHX Text

ANCHOR COLLAR / 2" WATER STOP/CONTINUOUSLY WELDED ON BOTH SIDES

AutoCAD SHX Text

WALL

AutoCAD SHX Text

STEEL WALL SLEEVE

AutoCAD SHX Text

PRESSURE PLATE

AutoCAD SHX Text

BOLT

AutoCAD SHX Text

ELASTOMERIC SEAL ELEMENT LS MODEL OR APPROVED EQUAL

AutoCAD SHX Text

3/4" TO 1" BRASS BUSHING TO 1" BRASS BUSHING

AutoCAD SHX Text

3/4" 90 BRASS ELBOW 90° BRASS ELBOW

AutoCAD SHX Text

3/4" HDPE SERVICE HDPE SERVICE

AutoCAD SHX Text

3/4" MNPT HDPE ADAPTER MNPT HDPE ADAPTER

AutoCAD SHX Text

NO SCALE

AutoCAD SHX Text

PIPE INSULATION

AutoCAD SHX Text

BACKFILL SEE NOTE 4

AutoCAD SHX Text NOTES: 1. PROVIDE INSULATION WHEN DEPTH OF COVER IS PROVIDE INSULATION WHEN DEPTH OF COVER IS LESS THAN 5 FEET. 2. THE INSULATION SHALL COMPLY WITH ASTM C578 THE INSULATION SHALL COMPLY WITH ASTM C578 TYPE IX. 3. OVERLAP ALL INSULATION BOARD JOINTS. OVERLAP ALL INSULATION BOARD JOINTS. 4. COMPACT PER SPECIFICATIONS.COMPACT PER SPECIFICATIONS.

AutoCAD SHX Text

TRACER WIRE

AutoCAD SHX Text

EXTEND INSULATION BOARD DOWN SIDES TO 6" BELOW WATER PIPE.

AutoCAD SHX Text

INSULATION BOARD PROVIDE 2-INCHES THICK PER FOOT OF COVER LOST.

AutoCAD SHX Text

3/4" DOUBLE BACKFLOW PREVENTER

AutoCAD SHX Text C

AutoCAD SHX Text C203

AutoCAD SHX Text C305

AutoCAD SHX Text C233

AutoCAD SHX Text C204

AutoCAD SHX Text C210

AutoCAD SHX Text C221

AutoCAD SHX Text C222

AutoCAD SHX Text C223

AutoCAD SHX Text C236

AutoCAD SHX Text C237

AutoCAD SHX Text D

AutoCAD SHX Text C305

AutoCAD SHX Text C305

AutoCAD SHX Text C306

AutoCAD SHX Text E

AutoCAD SHX Text C238

AutoCAD SHX Text C305

AutoCAD SHX Text C239

AutoCAD SHX Text B

AutoCAD SHX Text C205

AutoCAD SHX Text C305

AutoCAD SHX Text C216

AutoCAD SHX Text C237

AutoCAD SHX Text A

AutoCAD SHX Text C305

AutoCAD SHX Text C305

AutoCAD SHX Text C306

AutoCAD SHX Text DRAWING LOCATION: G:\Willis\23937-GRCA NORTH RIM (TOP) PHASE II\160057\CD\CIVIL\C305 DETAILS.dwg

AutoCAD SHX Text PLOT DATE: Tuesday, October 31, 2017 9:27:36 PM BY: ALATIMER

AutoCAD SHX Text

6" MIN.

AutoCAD SHX Text 1"

AutoCAD SHX Text

1/2" LP X 5" X 5"

AutoCAD SHX Text

1 1/2" DIA. GALVANIZED STEEL PIPE

AutoCAD SHX Text L

AutoCAD SHX Text L

AutoCAD SHX Text 1/2" P X 2 1/2" X 2 1/2"

AutoCAD SHX Text

1 1/4" STANDARD HEX NUT

AutoCAD SHX Text

TO MATCH VALVE BODY, PIPE OR METER

AutoCAD SHX Text

1/2" X 3" GALVANIZEDEXPANSION BOLTS (2 PER SUPPORT)

AutoCAD SHX Text

5/8" P X 2 1/2" X 6" BAR BENT AS SHOWN

AutoCAD SHX Text

ADJUSTABLE STEEL PIPE/VALVE SUPPORT

AutoCAD SHX Text

NO SCALE

AutoCAD SHX Text

DATE:

AutoCAD SHX Text

DESIGNED:

AutoCAD SHX Text

TECH. REVIEW:

AutoCAD SHX Text

SUB SHEET NO.

AutoCAD SHX Text

PMIS/PKG NO.

AutoCAD SHX Text

DRAWING NO.

AutoCAD SHX Text

SHEET

AutoCAD SHX Text

OF

AutoCAD SHX Text

TITLE OF SHEET

AutoCAD SHX Text

AutoCAD SHX Text 120423

AutoCAD SHX Text

AutoCAD SHX Text

PJS

AutoCAD SHX Text

AEL

AutoCAD SHX Text

JAM

AutoCAD SHX Text 11/01/2017

AutoCAD SHX Text

REPLACE NORTH RIM POTABLE WATER

AutoCAD SHX Text

DISTRIBUTION SYSTEM PHASE II

AutoCAD SHX Text 160057

AutoCAD SHX Text

DETAILS

AutoCAD SHX Text

AutoCAD SHX Text C305

AutoCAD SHX Text NOTE: 1. YARD HYDRANT TO BE YARD HYDRANT TO BE BACKFLOW PROTECTED WOODFORD, MODEL S3 OR APPROVED EQUAL.

AutoCAD SHX Text 1'-6"

AutoCAD SHX Text

METER VAULT (3-INCH OR LARGER)

AutoCAD SHX Text

NO SCALE

AutoCAD SHX Text C

AutoCAD SHX Text C302

AutoCAD SHX Text 2'-2"

AutoCAD SHX Text 2'-6"

AutoCAD SHX Text

LINK SEAL (TYP.)

AutoCAD SHX Text D

AutoCAD SHX Text C305

AutoCAD SHX Text A

AutoCAD SHX Text 6'

AutoCAD SHX Text 8'

AutoCAD SHX Text 10'

AutoCAD SHX Text 12'

AutoCAD SHX Text 2'

AutoCAD SHX Text 2'-6"

AutoCAD SHX Text

SUMP

AutoCAD SHX Text

3' X 3' ALUMINUM HATCH BILCO J-3AL OR EQUAL RATED FOR H20 LOADING.

AutoCAD SHX Text A

AutoCAD SHX Text C305

AutoCAD SHX Text

ALL PIPING INSIDE VAULT SHALL IN DI PIPE.

AutoCAD SHX Text 4.

AutoCAD SHX Text

NOTES:

AutoCAD SHX Text A

AutoCAD SHX Text C305

AutoCAD SHX Text

3'X3' ALUMINUM HATCH OVER METER TO FACILITATE REMOVAL

AutoCAD SHX Text

STRAINER

AutoCAD SHX Text

WATER METER WITH STRAINER RE: SPECS

AutoCAD SHX Text

BOLTED STEEL TRANSITION COUPLING (TYP)

AutoCAD SHX Text

PRECAST CONC VAULT

AutoCAD SHX Text

BYPASS. SAME SIZE AS MAIN.

AutoCAD SHX Text

WATER MAIN

AutoCAD SHX Text

STD ADJ SUPPORT (TYP)

AutoCAD SHX Text

CONC SUPPORT

alatimer Snapshot alatimer Text Box

EXPIRES 03/31/18

File details come from the government source that posted it.