Sol_140P1423R0004_Amd_0002.pdf
PDF 89 KB Posted
- Attached to
- Inspection and Repair of HVAC at Heritage Center
- Solicitation number
- 140P1423R0004
About this file
This amendment modifies a solicitation for inspection and repair services for an HVAC system at Yellowstone National Park. The amendment extends the proposal due date to January 10, 2023. It provides additional requirements for generator inspection, including load bank testing, a confidence test using the facility load, fluid analysis, draining and changing lubrication and coolant systems and filters, and replacing air filters. The amendment also clarifies that limitations on subcontracting compliance reporting is not applicable to this requirement. The period of performance is February 1, 2023 to April 24, 2023. The solicitation is issued by the National Park Service's Intermountain Region and relates to inspection and repair of the HVAC system at the Heritage Center in Yellowstone National Park.
View the file
Other files
Show all 11
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
(x)
140P1423R0004 x x
1 copies of the amendment; (b) By acknowledging receipt of this amendment on each copy of the offer submitted ; or (c) By separate letter or electronic communication which includes a reference to the solicitation and amendment numbers. FAILURE OF YOUR ACKNOWLEDGEMENT TO BE
RECEIVED AT THE PLACE DESIGNATED FOR THE RECEIPT OF OFFERS PRIOR TO THE HOUR AND DATE SPECIFIED MAY RESULT IN REJECTION OF YOUR
OFFER. If by virtue of this amendment you desire to change an offer already submitted , such change may be made by letter or electronic communication, provided each letter or electronic communication makes reference to the solicitation and this amendment, and is received prior to the opening hour and date specified.
x
PIR
Yellowstone NP WY 82190 Mammoth Supply Center / 22 Stable St PO Box 168 NPS, IMR - Northern Rockies MABO
01/03/20230002
13. THIS ITEM ONLY APPLIES TO MODIFICATION OF CONTRACTS/ORDERS. IT MODIFIES THE CONTRACT/ORDER NO. AS DESCRIBED IN ITEM 14.
12. ACCOUNTING AND APPROPRIATION DATA (If required) is not extended.is extended, Items 8 and 15, and returning
Offers must acknowledge receipt of this amendment prior to the hour and date specified in the solicitation or as amended , by one of the following methods: (a) By completing
The above numbered solicitation is amended as set forth in Item 14. The hour and date specified for receipt of Offers
11. THIS ITEM ONLY APPLIES TO AMENDMENTS OF SOLICITATIONS
FACILITY CODE CODE
10B. DATED (SEE ITEM 13)
10A. MODIFICATION OF CONTRACT/ORDER NO.
9B. DATED (SEE ITEM 11)
9A. AMENDMENT OF SOLICITATION NO.
CODE
8. NAME AND ADDRESS OF CONTRACTOR (No., street, county, State and ZIP Code)
7. ADMINISTERED BY (If other than Item 6)CODE 6. ISSUED BY
PAGE OF PAGES
4. REQUISITION/PURCHASE REQ. NO.3. EFFECTIVE DATE2. AMENDMENT/MODIFICATION NO. 5. PROJECT NO. (If applicable)
1. CONTRACT ID CODE
AMENDMENT OF SOLICITATION/MODIFICATION OF CONTRACT
12/02/2022
CHECK ONE A. THIS CHANGE ORDER IS ISSUED PURSUANT TO: (Specify authority) THE CHANGES SET FORTH IN ITEM 14 ARE MADE IN THE CONTRACT
B. THE ABOVE NUMBERED CONTRACT/ORDER IS MODIFIED TO REFLECT THE ADMINISTRATIVE CHANGES (such as changes in paying office, C. THIS SUPPLEMENTAL AGREEMENT IS ENTERED INTO PURSUANT TO AUTHORITY OF:
D. OTHER (Specify type of modification and authority) appropriation data, etc.) SET FORTH IN ITEM 14, PURSUANT TO THE AUTHORITY OF FAR 43.103(b).
E. IMPORTANT: Contractor is not is required to sign this document and return __________________ copies to the issuing office.
ORDER NO. IN ITEM 10A.
14. DESCRIPTION OF AMENDMENT/MODIFICATION (Organized by UCF section headings, including solicitation/contract subject matter where feasible.)
PROJECT DESCRIPTION: Inspection and Repair of HVAC System at Heritage Center, Yellowstone
National Park
Amendment 0001 to Solicitation #140P1423R0004 is issued to extend the date proposals are due, and to provide the generator data and a Past Performance Questionnaire. Additionally, Section 3.0 Specific work/task there is a callout for ¿generator inspection-100hr service" as follows:
1) Load Bank Testing ¿ Generator is placed under load for a period of time using an external load bank tester.
2) Confidence Test ¿ Generator is placed under load for a period of time using facility as
Continued ...
16A. NAME AND TITLE OF CONTRACTING OFFICER (Type or print)15A. NAME AND TITLE OF SIGNER (Type or print)
15C. DATE SIGNED 16B. UNITED STATES OF AMERICA 15B. CONTRACTOR/OFFEROR 16C. DATE SIGNED
(Signature of person authorized to sign) (Signature of Contracting Officer)
Stacy Vallie
STANDARD FORM 30 (REV. 11/2016)
Prescribed by GSA FAR (48 CFR) 53.243
Previous edition unusable
Except as provided herein, all terms and conditions of the document referenced in Item 9 A or 10A, as heretofore changed, remains unchanged and in full force and effect .
ITEM NO. SUPPLIES/SERVICES QUANTITY UNIT UNIT PRICE AMOUNT
NAME OF OFFEROR OR CONTRACTOR
2 2
CONTINUATION SHEET
REFERENCE NO. OF DOCUMENT BEING CONTINUED PAGE OF
(A) (B) (C) (D) (E) (F)
140P1423R0004/0002 a load.
3) Fluid Analysis ¿ Lubricating oil, and coolant analysis performed by laboratory.
4) Drain lubrication system ¿ change filters and oil.
5) Drain coolant ¿ change coolant filters and coolant.
6) Replace air filters.
Instructions included under Volume II #4, included the following, "Offerors shall complete the "Limitations on Subcontracting Compliance
Report Template" (Attachment 9) or otherwise submit information with their price proposal which includes confirmation of their intent to comply with 52.219-14" This is not applicable to this requirement.
Proposals are now due no later than 1:00 p.m.
Mountain Standard Time on January 10, 2023.
END OF AMENDMENT 0002
Period of Performance: 02/01/2023 to 04/24/2023
NSN 7540-01-152-8067 OPTIONAL FORM 336 (4-86)
Sponsored by GSA
FAR (48 CFR) 53.110
File details come from the government source that posted it. Updated .