GENERAL NOTES
1. ALL WET AREAS SHALL HAVE MOISTURE RESISTANT GWB AND CTBB BEHIND WALL TILE. (MATCH
THICKNESS OF CTBB TO GWB)
2. ALL EXPOSED FINISHED WOOD WORK (T&G CEILING, WOOD JOISTS AND COLUMNS, TRIM, ETC.) SHALL
BE SANDED SMOOTH, STAINED AND SEALED, COLOR AS SELECTED BY CONTRACTING OFFICER.
3. ALL GWB THROUGHOUT SHALL BE PAINTED. COLOR SHALL BE SELECTED BY CO.
FLOOR FINISH KEY:
CONC - SEAL = SEALED CONCRETE
CONC - STN = POLISHED, STAINED, AND SEALED CONCRETE
EPOXY = FLUID APPLIED EPOXY FLOORING WITH 6" INTEGRAL BASE
CPT = CARPET
WALL FINISH KEY:
GWB = GYPSUM WALL BOARD (MOISTURE RESISTANT AT WET AREAS)
PT-1 = PAINT FINISH, BASE COLOR
PT-2 = PAINT FINISH, ACCENT COLOR
BF/EP = BLOCK FILLER AND EPOXY PAINT AT CONC BLOCK WALLS
WALL BASE KEY:
EPOXY = EPOXY BASE
WD = WOOD BASE
RB = RUBBER BASE
CEILING FINISH KEY:
OPEN = OPEN TO STRUCTURE (REFINISH WOOD T&G CEILING AND WOOD STRUCTURE)
GWB = GYPSUM BOARD CEILING - PAINTED WHITE
D
HF
E GA B C
3.5
6.5
WOMEN'S
MEN'S
JAN.
UNISEX
ASTRO
STORAGE
STOR &
IT
HALL
TS
TS
TS
TD
TD
TD
TD
TD
TD
STAFF
RR
OFFICE
NHA
OFFICE
4' - 0"
TS TD
3.2
C.7C.1
6.8
TS
/4
VEST.
VISITOR
CONTACT
SPACE
TD
FINISH PLAN LEGEND
FLUID APPLIED EPOXY FLOORING
WITH INTEGRAL BASE
POLISHED, STAINED, AND SEALED
CONC
CPT
WALK-OFF MAT
SEALED CONC (NO STAIN)
PROVIDE T&G SHIPLAP SIDING
THRESHOLD
TRANSITION STRIP
TD
TS
TITLE OF SHEETSUB SHEET NO.DESIGNED:
TECH REVIEW:
DATE:
DRAWING NO.
PMIS/PKG NO.
SHEET
OF9/
/2
8:
:4
P
M C
:\U se rs \lo ga nb on d\
D es kt op
\2
N
P S
C E
D A
R B
R E
A K
S _R
L B
.r vt
A6.1
ADE
VISITOR CONTACT CENTER
CEDAR BREAKS NATIONAL MONUMENT
147064
163432
LWB
09/11/2020 44 108
FINISH PLAN &
SCHEDULE
SCALE OF FEET
16808
SCALE A
ROOM FINISH SCHEDULE
ROOM
NUMBER NAME
FLOOR
FINISH
CEILING
FINISH
NORTH WALL EAST WALL SOUTH WALL WEST WALL
COMMENTS
WALL
FINISH BASE
WALL
FINISH BASE
WALL
FINISH BASE
WALL
FINISH BASE
101 ASTRO STORAGE CONC -
SEAL
GWB GWB RB GWB RB GWB RB GWB RB
102 OFFICE CPT GWB GWB RB GWB RB GWB RB GWB RB
103 STAFF RR EPOXY GWB CT-1 / GWB EPOXY CT-1 / GWB EPOXY CT-1 / GWB EPOXY CT-1 /GWB EPOXY
104 NHA OFFICE CPT GWB GWB RB GWB RB GWB WD GWB RB
105 STOR & IT CONC -
SEAL
GWB GWB RB GWB RB GWB RB GWB RB
106 VISITOR CONTACT
SPACE
CONC - STN
- SEAL
T&G GWB WD GWB WD GWB/T&G WD GWB WD T&G CLNG - STN
107 VEST. MTL GRATE T&G T&G WD - - T&G WD T&G WD WALK-OFF MAT
108 HALL CPT GWB GWB WD GWB WD GWB WD GWB WD
201 WOMEN'S EPOXY GWB BF/EP EPOXY CT-1 / GWB EPOXY CT-1 / GWB EPOXY CT-1 EPOXY
202 UNISEX EPOXY GWB BF/EP EPOXY CT-1 / GWB EPOXY CT-1 / GWB
& BF/EP
EPOXY CT-1/GWB EPOXY
203 JAN. CONC -
SEAL
GWB BF/EP EPOXY BF/EP EPOXY BF/EP EPOXY CT-1 /GWB EPOXY
204 MEN'S EPOXY GWB CT-1 / GWB EPOXY CT-1 / GWB EPOXY BF/EP EPOXY CT-1 EPOXY
PRELIMINARY
NOT FOR
CONSTRUCTION
%100 DRAFT CD
A6.1
FINISH PLAN1
SCALE A
E13E13E13
E14
E15
E4
E15
E38E38
A8.3
E15
E34
E13E13
E35 E35
E38
MULTILEVEL TRANSACTION
COUNTER: REF. A8.4
10' - 10 1/4"
E13E13
E15E15
E33 E35E35
E38E38
E13E13
E15
E33
E13E13
E35 E35
E38E38
GENERAL NOTES
1. WD T&G AND STONE SHOWN FOR GRAPHIC
REPRESENTATION ONLY - NOT TO SCALE.
2. FIXTURES SHOWN FOR GRAPHIC PURPOSES ONLY: REF.
PRODUCT FILE.
TITLE OF SHEETSUB SHEET NO.DESIGNED:
TECH REVIEW:
DATE:
DRAWING NO.
PMIS/PKG NO.
SHEET
OF9/
/2
8:
:4
P
M C
:\U se rs \lo ga nb on d\
D es kt op
\2
N
P S
C E
D A
R B
R E
A K
S _R
L B
.r vt
A7.0
ADE
VISITOR CONTACT CENTER
CEDAR BREAKS NATIONAL MONUMENT
147064
163432
LWB
09/11/2020 45 108
INTERIOR
ELEVATIONS
A7.0
INTERP. SPACE / BOOKSTORE NORTH1
A7.0
BOOKSTORE EAST2
A7.0
INFO COUNTER SOUTH3
A7.0
INTERP. SPACE WEST4
PRELIMINARY
NOT FOR
CONSTRUCTION
%100 DRAFT CD
SCALE OF FEET
SCALE A
SCALE ASCALE A
SCALE A SCALE A
KEYNOTES
E4 STONE VENEER ON FRAME CONSTRUCTION AT CHIMNEY:REF.
A8.3.
E13 SURFACE MOUNTED UNIT HEATER: REF. MECH.
E14 WD BURNING FIREPLACE INSERT.
E15 1X10 WD BASE TRIM- STN.
E33 WD T&G FINISH - OPAQUE STN.
E34 WD T&G FINISH - STN TO MATCH GLUEL-AMS.
E35 GLUELAM BEAM: REF. STRUC. - STN.
E38 GWB - PT, TYP.
E15 E13
E38
105A
E13 E15
E38
E15
E3 E38
E15
E38
E30
E13
E38
105B
E30
E13
E38
E30
E3
E38
105A
E30
E13
E38
E15 E15
E38
E15 E13
E38
E15
E3 E38
101A
E15
E38
E30
E13
E38
101A
E30
E13
E38
E30
E13
E38
101B
E30
E38
E15
E32
E38
E15
E32
E38
E15
E19
E38
E15
E19
E38
GENERAL NOTES
1. FOR ROOMS 102 & 104 ALL DR AND STOREFRONT TRIM IS TO BE A 1X4
TITLE OF SHEETSUB SHEET NO.DESIGNED:
TECH REVIEW:
DATE:
DRAWING NO.
PMIS/PKG NO.
SHEET
OF9/
/2
8:
:5
P
M C
:\U se rs \lo ga nb on d\
D es kt op
\2
N
P S
C E
D A
R B
R E
A K
S _R
L B
.r vt
A7.1
ADE
VISITOR CONTACT CENTER
CEDAR BREAKS NATIONAL MONUMENT
147064
163432
LWB
09/11/2020 46 108
INTERIOR
ELEVATIONS
PRELIMINARY
NOT FOR
CONSTRUCTION
%100 DRAFT CD
SCALE OF FEET
SCALE A
KEYNOTES
E3 AL STOREFRONT WINDOW SYSTEM: REF. STOREFRONT ELEVATIONS A6.0.
E13 SURFACE MOUNTED UNIT HEATER: REF. MECH.
E15 1X10 WD BASE TRIM- STN.
E19 ELEC CABINET: REF. ELEC.
E30 4" RUBBER BASE.
E32 SERVER CABINET AND PLYWD BACKERBOARD: REF. ELEC.
E38 GWB - PT, TYP.
A7.1
NHA OFFICE 104 NORTH1
A7.1
NHA OFFICE 104 EAST2
A7.1
NHA OFFICE 104 SOUTH3
A7.1
NHA OFFICE 104 WEST4
A7.1
STOR & IT NORTH5
A7.1
STOR & IT EAST6
A7.1
STOR & IT SOUTH7
A7.1
STOR & IT WEST8
A7.1
OFFICE 102 NORTH9
A7.1
OFFICE 102 EAST10
A7.1
OFFICE 102 SOUTH11
A7.1
OFFICE 102 WEST12
A7.1
STORAGE 101 NORTH13
A7.1
STORAGE 101 EAST14
A7.1
STORAGE 101 SOUTH15
A7.1
STORAGE 101 WEST16
A7.1
HALL 108 NORTH17
A7.1
HALL 108 EAST18
A7.1
HALL 108 SOUTH19
A7.1
HALL 108 WEST20
File details come from the government source that posted it. Updated .