140L5725R0003_Attachment_03_Supplamental_Drawings.pdf
PDF 9 MB Posted
- Attached to
- Calf Creek Bridge Replacement Federal contract opportunity
- Solicitation number
- 140L5725R0003
About this file
This document is a set of standard drawings for guardrail and roadway infrastructure installation from the Utah Department of Transportation. The drawings cover multiple technical specifications for guardrail systems, including W-beam guardrail hardware, steel and wood posts, terminal sections, cable releasing terminals, and installation details. Key components include detailed technical diagrams for:
- Midwest Guardrail System (MGS) panels with specific measurements for post spacing, bolt configurations, and panel dimensions. The drawings provide precise installation guidance for different guardrail scenarios, including wood and steel posts, approach transitions, and end treatments. Specifications include galvanized hardware, post markings, and installation requirements that comply with AASHTO standards and MASH (Manual for Assessing Safety Hardware) compliance. Additional details cover installation angles, post lengths, and grading requirements for various roadway conditions and traffic speeds.
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| Sol_140L5725R0003_Amd_0001.pdf | ||
| 140L5725R0003_Amendment_0001_-_Attachment_08_Site_Visit_Notes_Images_0001.pdf | ||
| 140L5725R0003_Attachment_06_Wage_Determination_UT20250009_01_03_2025.pdf | ||
| 140L5725R0003_Attachment_02_Drawings.pdf | ||
| 140L5725R0003_Attachment_04_GSENM_Calf_Creek_EA_Final.pdf | ||
| 140L5725R0003_Attachment_05_Bid_Schedule.xlsx | XLSX spreadsheet | |
| Sol_140L5725R0003.pdf | ||
| 140L5725R0003_Attachment_07_Limitations_on_Subcontracting_Breakout.xlsx | XLSX spreadsheet | |
| 140L5725R0003_Attachment_01_Specifications.pdf |
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
GUARDRAIL
BLOCK
DELINEATOR DETAIL
18 INCH BOLT-POST5/8 INCH X
/4 I
N C
H
/3
M A
R
D G
N
F i l e
O
S t a n d a r d s a n d
S p e c s S e c t i o n J m
B u c k l e y
S t a n d a r d
D a w i n g h e c k
B A e r i e s
B A
A .d g n
U T
A H D
E P
A R
T M
E N
T O
F T
R A
N S
P O
R T
A T
IO
N
S A
L T L
A K
E C
IT
Y
U T
A H
S T
A N
D A
R D D
R A
W
IN
G S F
O R R
O A
D A
N D B
R
ID
G E C
O N
S T
R U
C T
IO
N
R E
V
IS
IO
N S
D A
T E
N O
A P
P R
R E
M A
R K
S
STD. DWG. NO.
S T
A N
D A
R D D
R A
W
IN
G T
IT
L E
BA 4A
NOTES:
GALVANIZED BOLTS, NUTS, WASHERS
6 INCH X 8 INCH WOOD POST W6 X 8.5 STEEL POST
DELINEATOR DETAIL
6 INCH X 8 INCH NOTCHED WOOD BLOCK6 INCH X 8 INCH WOOD BLOCK
WOOD POST W/ WOOD BLOCK (MEDIAN) 25 INCH
WOOD POST W/ WOOD BLOCK 18 INCH
STEEL BOLT W/ WOOD BLOCK 10 INCH
SPLICE BOLTS (WASHER NOT REQ'D.) 1 1/4 INCH
L
USE BOTTOM HOLE FOR INITIAL INSTALLATION
AND GW 10 FOR PLACEMENT
SEE STD DWG GW 9 FOR HARDWARE
WOOD POST W/WOOD BLOCK
SEE NOTE 5SEE NOTE 4
/4 I
N C
H
12 1/4 INCH
9/16 INCH3 1/4 INCH2 5/16"
NEUTRAL
AXIS
STEEL
GALVANIZED
1 INCH R
1" R
2 1/2 INCH SLOT
3/4 INCH X
8"
3"
3"
SEE NOTE 2
13/16 INCH HOLES
SIDE FRONT SIDE FRONT
1 1/8"
1 1/8"
6"
TOP
SEE NOTE 2
13/16 INCH HOLES
PLASTIC WASHER.
NEOPRENE, NYLON, OR
SHANK NAILS WITH
2 1/2 INCH GALVANIZED RING
OPTIONAL PLACEMENT
ATTACH DELINEATOR
AND NUTS TO
GALVANIZED BOLTS
USE TWO 1/4 INCH x 1 INCH
DRILL TWO 1/4 INCH HOLES.
L 5/8"
5/8 INCH X L
BUTTON HEAD BOLT
BLOCK
GUARDRAIL
5/8 INCH X 18 INCH BOLT-POST
SEE NOTE 4
GALVANIZED STEEL BAND
13/16 INCH DIA HOLE
NUT
WASHER
INCH DIA HOLE 16
NUT
WASHER
8"
I
N C
H
3"
3"
/2
/2
3/4"
4 1/2" 3/4"
8"
6"
2"
TOP
FRONT
SIDEFRONTSIDE
PLASTIC WASHER.
NEOPRENE, NYLON, OR
SHANK NAILS WITH A
2 1/2 INCH GALVANIZED RING
SEE NOTE 4
GALVANIZED STEEL BAND
13/16 INCH HOLE
13/16 INCH BOLT HOLE
6 1/4 INCH
4 1/4"
8 1/2 INCH2"
3/4 INCH X 2 1/2 INCH POST BOLT SLOT
3 FT 1-1/2 INCH3 FT 1-1/2 INCH6 1/4 INCH
H A
R D
W A
R E
W -B
E A
M G
U A
R D
R A
IL
M
ID
W E
S T
I
N
STANDARD MIDWEST GUARDRAIL (MGS) PANELS
SEE NOTES 1, 3 & 4
SEE NOTES 1 & 3
AND GW 7A FOR PLACEMENT
SEE STD DWG GW 6B FOR HARDWARE
OR COMPOSITE BLOCK
STEEL POST W/WOOD
3 FT 1-1/2 INCH3 FT 1-1/2 INCH
29/32 INCH x 1 1/8 INCH SPLICE BOLT HOLE
6 FT 3 INCH, 9 FT 4 1/2 INCH, 12 FT 6 INCH, 18 FT 9 INCH, OR 25 FT
/2
/2
S
D D
M O
D
IF
IE
D S
L O
T D
IM
E N
S
IO
N T
O M
E E
T A
A S
H T
O M
-1
M O
D
IF
IE
D M
G S P
A N
E L
D E
L E
T E
D N
O T
E
S E
E N
O T
E
F
T F
T
O R F
T
7 3
S E
E N
O T
E
F
T F
T
O R F
T
/2
/2
S D
D M
O D
IF
IE
D P
O S
T L
E N
G T
H R
E Q
U
IR
E M
E N
T
M O
V E
D B
L O
C K L
O C
A T
IO
N T
O P O
F P
O S
T
E
IL
IT
Y T
O R
A
IS
E B
L O
C K
A B
O V
E P
O S
T
WOOD POST TO GUARDRAIL TYPICAL
SECTION THRU GUARDRAIL ELEMENT STEEL POST TO GUARDRAIL TYPICAL
HIGHWAY BARRIER HARDWARE.
6. MANUFACTURE ACCORDING TO AASHTO GUIDE TO STANDARDIZED
COMPLIANCE REQUIRED.
NOTCHED WOOD BLOCK ON STEEL POST INSTALLATION. MASH
5. A COMPOSITE OR PLASTIC BLOCK CAN BE SUBSTITUTED FOR THE
WITH STEEL POSTS AND WOOD OR COMPOSITE BLOCKS.
GALVANIZED OR STAINLESS STEEL BAND. BANDING NOT REQUIRED
4. BAND WOOD BLOCKS TO WOOD POSTS WITH 1/2 INCH STEEL
3. DO NOT USE WASHERS ON RAIL FACE OR SPLICE CONNECTION.
E. BRAND OR STAMP POSTS BEFORE INSTALLATION.
OF POST.
D. PLACE STAMP OR BRAND NO MORE THAN 7 INCH FROM TOP
C. BRAND WOOD POSTS WITH 3/4 INCH MARKING.
B. STAMP STEEL POSTS WITH 3/4 INCH MARKING.
3) MARK POSTS WITH "8" IF POST LENGTH IS 8 FT.
2) MARK POSTS WITH "7" IF POST LENGTH IS 7 FT.
1) DO NOT MARK POSTS IF POST LENGTH IS 6 FT.
A. MARKINGS
2. MARK POST LENGTH ON GUARDRAIL POSTS AS FOLLOWS:
POST LENGTH REQUIREMENTS AND HOLE USAGE REQUIREMENT.
1. SEE INSTALLATION DETAIL STD DWG BA 4D1 OR BA 4D2 FOR
POST
SEE NOTE 6
/2
/2
S D
D C
O R
R E
C T
E D N
O T
E C
A L L
O U
T S
R E
M O
V E
D U
N N
E E
D E
D A
R R
O W
S
S T
A N
D A
R D D
R A
W
IN
G E
D
IT
IO
N
S ta nd ar d D ra w in
M A
R
D l e
O
S t a n d a r d s a n d
S p e c s S e c t i o n J u c k l e y a n d a d a w i n h e c k
B r i e s
B A
B .d g n
U T
A H D
E P
A R
T M
E N
T O
F T
R A
N S
P O
R T
A T
IO
N
S A
L T L
A K
E C
IT
Y
U T
A H
R E
C O
M M
E N
D E
D F
O R A
P P
R O
V A
L
A P
P R
O V
E D
D E
P U
T Y D
IR
E C
T O
R
R E
V
IS
IO
N S
D A
T E
N O
A P
P R
R E
M A
R K
S
C H
A
IR
M A
N S
T A
N D
A R
D S C
O M
M
IT
T E
E
D A
T E
D A
T E
STD. DWG. NO.
S T
A N
D A
R D D
R A
W
IN
G T
IT
L E
S T
A N
D A
R D D
R A
W
IN
G S F
O R R
O A
D A
N D B
R
ID
G E C
O N
S T
R U
C T
IO
N
H A
R D
W A
R E
B A
R R
IE
R
T
R A
N S
IT
IO
N
G U
A R
D R
A
IL
N C
R E
TERMINAL CONNECTOR
10 GAUGE THRIE-BEAM
13'-6 1/2"
/1
/8
/1
BOLT SLOT, TYP
29/32" x 1 1/8" SPLICE
12 GAUGE 8-SPACE THRIE-BEAM GUARDRAIL
BOLT SLOT, TYP
3/4" x 2 1/2" POST
TYP
8 1/2"
TYP
2"
6-1/4"8 SPACES AT 1'-6 3/4" = 12'-6"6-1/4"
TO THRIE-BEAM TRANSITION
10 GAUGE ASYMMETRICAL W-BEAM
7"
/1
/8
/1
3"2"
/8
2'-6"
3 1/8"
1" x 2" SLOTTED HOLE, TYP
1" DIA HOLE, TYP
/8
/8
HOLE SLOT, TYP
3/4" x 2 1/2" POST
6 1/4" 6 1/4"6'-3"
7'-3 1/2"
2"
8 1/2"
2"
8 1/2"
BA 4B1
POSTS INSTALLATION. MASH COMPLIANCE REQUIRED.
1. A COMPOSITE OR PLASTIC BLOCK CAN BE SUBSTITUTED FOR THE NOTCHED WOOD BLOCK ON STEEL
NOTES:
12 GUAGE 4-SPACE THRIE-BEAM GUARDRAIL
BOLT SLOT, TYP
3/4" x 2 1/2" POST
BOLT SLOT, TYP
29/32" x 1 1/8" SPLICE
13'-6 1/2"
6-1/4"4 SPACES AT 3'-1 1/2" = 12'-6"6-1/4"
87 1/2"
6-1/4"2 SPACES AT 3'-1 1/2" = 6' 3"6-1/4"
12 GAUGE 2-SPACE THRIE-BEAM GUARDRAIL
/2
/2
3/4"
4 1/2" 3/4"
8"
6"
2"
TOP FRONTSIDE
13/16" BOLT HOLE
SIDE FRONT
1 1/8"
1 1/8"
6"
TOP
" 13/16" HOLES
CL
/8
/8
W6 X 8.5 STEEL THRIE-BEAM POST
6 INCH X 8 INCH NOTCHED THRIE-BEAM WOOD BLOCK
O R
SEE NOTE 1
/1
/8
/1
/1
/8
/1
TYP
8 1/2"
TYP
2"
TYP
8 1/2"
TYP
2"
4"4"
/2
/2
TERMINAL CONNECTOR PLATE
/4
2"
2'-6"
3"4"4"
FOR 7/8" DIA BOLTS
1" DIA HOLES
POST BOLT SLOT
3/4" x 2 1/2"
1" x 3" SLOTS
LC
LC
4" 8 1/2" 8 1/2" 4"
/1
/8
/1
BOLT SLOT, TYP
29/32" x 1 1/8" SPLICE
BOLT SLOT, TYP
3/4" x 2 1/2" POST
/8
2'-6"
3 1/8"
/2
/2
S D
D R
E N
U M
B E
R E
D B
A
B
A T
O B
A
B A
N D R
E V
IS
E D
BOLT SLOT, TYP
29/32" x 1 1/8" SPLICE
S ta nd ar d D ra w in
A P
R
D l e
O
S t a n d a r d s a n d
S p e c s S e c t i o n a n d a r d s
(p u b
S p r i n g
E l e c t r o n c o o k s
M a s t a w i n g s
D R
A W I N
G S
U p d a t s a d e f r o
Q
E D t o b e a d d e d t o b o o k
B A
B
A .d g n
U T
A H D
E P
A R
T M
E N
T O
F T
R A
N S
P O
R T
A T
IO
N
S A
L T L
A K
E C
IT
Y
U T
A H
R E
V
IS
IO
N S
D A
T E
N O
A P
P R
R E
M A
R K
S
STD. DWG. NO.
S T
A N
D A
R D D
R A
W
IN
G T
IT
L E
S T
A N
D A
R D D
R A
W
IN
G S F
O R R
O A
D A
N D B
R
ID
G E C
O N
S T
R U
C T
IO
N
N E
W D
R A
W
IN
G
S D
D
NOTES:
L A
Y O
U T S O
F
T R
A N
S
IT
IO
N
G U
A R
D R
A
IL
/3
/2
BA 4B2A
/1
/2
S D
D
/1
/2
S D
D M
O V
E D A
A S
H T
O I
N F
O R
M A
T
IO
N I
N T
O S
P E
C
IF
IC
A T
IO
N
R E
M O
V E
D T
A S
K F
O R
C E
R
E F
E R
E N
C E
S F
R O
M N
O T
E S
S T
A N
D A
R D D
R A
W
IN
G E
D
IT
IO
N
SEE NOTE 3
PIN, TYP
STABILIZATION
1 2 3 4 5 6
CONNECTOR SEE NOTE 5
10 GAUGE THRIE-BEAM TERMINAL
OR FULL HEIGHT CONSTANT SLOPE BARRIER.
12. DO NOT CONNECT AN APPROACH TRANSITION TO CONSTANT SLOPE BRIDGE PARAPET
11. SEE STD DWG BA 1F3 FOR THRIE-BEAM TERMINAL CONNECTOR BOLT REQUIREMENTS.
10. SEE STD DWG BA 4A GALVANIZED BOLT REQUIREMENTS.
9. DO NOT USE ROTARY PERCUSSION DRILL. CORE DRILLING REQUIRED.
TERMINAL CONNECTOR JOINT.
8. USE RECTANGULAR GUARDRAIL WASHERS UNDER NUTS AT THRIE-BEAM TO
7. DO NOT ATTACH RAIL AT POST 8.
6. SEE STD DWG BA 4A FOR W6x8.5 STEEL POST DETAILS FOR POST 7 THRU 9.
5. SEE STD DWG BA 4B2D FOR TRANSITION CONNECTION REQUIREMENTS.
4. SEE STD DWG BA 4B1 FOR POST 1 THRU 6 DETAIL.
BA 1F SERIES.
SEGMENTS AND CONNECT TO A GUARDRAIL TRANSITION. SEE STD DWG BA 1A2 AND
CONCRETE BARRIER F-SHAPEPRECAST 3. INSTALL STABILIZATION PIN AT THE LAST THREE
TO EDGE OF TRAVEL LANE.
2. INSTALL THE LAST 3 PRECAST BARRIER SEGMENTS IN A TANGENT LINE PARALLEL
1. COMPLETE SITE PREPARATION BEFORE INSTALLING TRANSITION.
LC
7 8 9
FINISHED GRADE
BEFORE END TREATMENT
25 FT MIN MGS REQUIRED
MGS TRANSITION
10 GUAGE ASYMMETRICAL
12" 5 SPACES AT 1'- 6 3/4" = 7'- 9 3/4"
6 - 7' W6x8.5 STEEL THRIE-BEAM POSTS
3'-1 1/2" 2 SPACES AT 3'-1 1/2" = 6'-3"
ELEVATION
WASHER 2 EACH PLACE
LAG SCREW, 5/8 X 3" WITH
SEE DETAIL 1
TRANSITION BLOCKOUTS
12 GAUGE 4-SPACE THRIE-BEAM GUARDRAIL THRIE-BEAM GUARDRAIL
12 GAUGE 2-SPACE
12 GUAGE NESTED 8-SPACE THRIE-BEAM GUARDRAIL
END OF BARRIER
END OF BARRIER
END OF BARRIER
15-FT F-SHAPE BARRIERS
THRIE-BEAM GUARDRAIL APPROACH TRANSITION
APPROACH
PLAN VIEW
END OF BARRIER
SEE NOTE 7
SEE NOTE 6
W6x8.5 STEEL POSTS
SEE NOTES 2 & 3
B-2B-3 B-1
SEE NOTE 8
SEE NOTE 10
TYP 12 PLACES
WITH NUT AND WASHERS
5/8" DIA GAURDRAIL BOLT
SEE NOTE 10
TYP 8 PLACES
WITH NUT AND WASHERS
5/8" DIA GAURDRAIL BOLT
7 1/4"6 1/8"5"
3" 6"
5 1/4"
3" (TYP)4 1/8"
DETAIL 1: PRECAST F-SHAPE TRANSITION WOOD BLOCKOUTS
/8
B-1B-2B-3
1/2" DIA (TYP)
GUARDRAIL APPROACH TRANSITION TO PRECAST F-SHAPE BARRIER
RIGHT SIDE SHOWN, LEFT SIDE SIMILAR
/2
/2
S D
D F
U L L R
E V
IS
IO
N
S ta nd ar d D ra w in g
Dana Cork Sticky Note Can we add the crash test data for this railing. The standard it meets (AASHTO MASH, NCHRP, etc.) and the test level. If it meets MASH is that 2009 or 2016.? If it meets NCHRP which report? Basically, I want to look at this drawing and be able to determine how to code SNBI item B.RH.02 for the transition railing.
COVER
MINIMUM
DIAMETER
VALENT
EQUI-
RADIUS
CORNER
MINIMUM
COVER
MINIMUM
COVER
MINIMUM
COVER
MINIMUM
DIAMETER
VALENT
EQUI-
RADIUS
CORNER
MINIMUM
142 x 91
137 x 87
128 x 83
117 x 79
112 x 75
103 x 71
95 x 67
87 x 63
83 x 57
81 x 59
77 x 52
73 x 55
71 x 47
66 x 51
64 x 43
60 x 46
57 x 38
49 x 33
42 x 29
35 x 24
28 x 20
24 x 18
21 x 15
17 x 13
MAXIMUM FILL HEIGHT ABOVE TOP OF PIPE (FEET) MAXIMUM FILL HEIGHT ABOVE TOP OF PIPE (FEET)
MAXIMUM FILL HEIGHT ABOVE TOP OF PIPE (FEET) MAXIMUM FILL HEIGHT ABOVE TOP OF PIPE (FEET)
INCHES INCHES
0.064/160.079/140.109/120.138/10 0.168/8 0.064/160.079/140.109/120.138/10 0.168/8 0.064/160.079/140.109/120.138/10 0.168/8
INCHES INCHES INCHES INCHES
0.060/160.075/140.105/120.135/10 0.164/8 0.060/160.075/140.105/120.135/10 0.164/8
INCHES INCHES
0.064/160.079/140.109/120.138/10 0.168/8 0.079/140.109/120.138/10 0.168/8 0.079/140.109/120.138/10 0.168/8 0.060/160.075/140.105/120.135/100.060/160.075/140.105/120.135/10
INCHESINCHES INCHES INCHES
NO SCALE
NOTE:
of camber or increase the pipe culvert gradient.
elevation of the inlet invert, reduce the amount parabolic curve as designed exceeds the curve. If the midpoint elevation on the pipe length. Develop camber on a parabolic inverts an ordinate amount equal to 1% of the from a chord through the inlet and outlet
When directed, camber pipe culverts upward
4.
3.
2.
1.
culvert to the top of the pavement.
maximum fill height from the top of the pipe
For all roadway surface types, measure pipe culvert to the top of the pavement.
measure minimum cover from the top of the roadway subgrade. For rigid pavements, top of the pipe culvert to the bottom of the roadways, measure minimum cover from the
For flexible pavement and aggregate surface corrugation pipe.
Obtain approval before furnishing annular of helical lockseam and welded seam pipe.
corrugations are more restrictive than those
Fill heights for culvert pipe with annular lockseam and welded seam pipe only.
The fill heights in the table are for helical special analysis by the CO.
METAL ROUND PIPE CULVERT
FILL HEIGHT AND METAL THICKNESS TABLE FOR HELICAL LOCKSEAM AND WELDED SEAM PIPE CULVERT
METAL PIPE ARCH CULVERT
FILL HEIGHT AND METAL THICKNESS TABLE FOR HELICAL LOCKSEAM AND WELDED SEAM PIPE CULVERT
Fill heights exceeding 100 feet require
STEEL ALUMINUM
DIAMETER
SIZE
PIPE
SPAN x RISE
SIZE
PIPE ARCH
ALUMINUMSTEEL
DIAMETER
SIZE
PIPE
SPAN x RISE
SIZE
PIPE ARCH
" CORRUGATIONS2
" x 3
2 3" x 1" CORRUGATIONS 5" x 1" CORRUGATIONS
METAL THICKNESS (INCH/GAGE) METAL THICKNESS (INCH/GAGE)
" CORRUGATIONS2
" x 3
2 3" x 1" CORRUGATIONS
" CORRUGATIONS2
" x 3
METAL THICKNESS (INCH/GAGE)
3" x 1" CORRUGATIONS 5" x 1" CORRUGATIONS " CORRUGATIONS2
" x 3
2 3" x 1" CORRUGATIONS
METAL THICKNESS (INCH/GAGE)
3.5
103 x 71
95 x 67
87 x 63
81 x 59
73 x 55
66 x 51
64 x 43
60 x 46
57 x 38
49 x 33
42 x 29
35 x 24
28 x 20
24 x 18
21 x 15
17 x 13
3.5
METAL PIPE CULVERT
602-1
FP-24, FP-14
8/2024
FLH STANDARD
:1
P
A u g u s t
S td p w w o r k \d
\S td .d g n
OFFICE OF FEDERAL LANDS HIGHWAY
U.S. DEPARTMENT OF TRANSPORTATION, FHWA
SPECIFICATION
APPROVED FOR USE
PROJECT
NUMBER
SHEET
COVER
MINIMUM
DIAMETER
VALENT
EQUI-
RADIUS
CORNER
MINIMUM
COVER
MINIMUM
COVER
MINIMUM
COVER
MINIMUM
DIAMETER
VALENT
EQUI-
RADIUS
CORNER
MINIMUM
Dimensions without units are millimeters.
units of measure. Metric This drawing contains
MAXIMUM FILL HEIGHT ABOVE TOP OF PIPE (METERS)
1.63 2.01 2.77 3.51 4.27 1.63 2.01 2.77 3.51 4.27 1.63 2.01 2.77 3.51 4.27
MAXIMUM FILL HEIGHT ABOVE TOP OF PIPE (METERS)
1.52 1.91 2.67 3.43 4.17 1.52 1.91 2.67 3.43 4.17
3610 x 2310
3480 x 2210
3250 x 2110
2970 x 2010
2840 x 1910
2620 x 1800
2410 x 1700
2210 x 1600
2110 x 1450
2060 x 1500
1960 x 1320
1850 x 1400
1800 x 1190
1680 x 1300
1630 x 1090
1520 x 1170
1450 x 970
1240 x 840
1070 x 740
890 x 610
710 x 510
610 x 460
530 x 380
430 x 330
MAXIMUM FILL HEIGHT ABOVE TOP OF PIPE (METERS)
1.63 2.01 2.77 3.51 4.27 2.01 2.77 3.51 4.27 2.01 2.77 3.51 4.27
MAXIMUM FILL HEIGHT ABOVE TOP OF PIPE (METERS)
1.52 1.91 2.67 3.43 1.52 1.91 2.67 3.43
NO SCALE
NOTE:
of camber or increase the pipe culvert gradient.
elevation of the inlet invert, reduce the amount parabolic curve as designed exceeds the curve. If the midpoint elevation on the pipe length. Develop camber on a parabolic inverts an ordinate amount equal to 1% of the from a chord through the inlet and outlet
When directed, camber pipe culverts upward
4.
3.
2.
1.
culvert to the top of the pavement.
maximum fill height from the top of the pipe
For all roadway surface types, measure pipe culvert to the top of the pavement.
measure minimum cover from the top of the roadway subgrade. For rigid pavements, top of the pipe culvert to the bottom of the roadways, measure minimum cover from the
For flexible pavement and aggregate surface corrugation pipe.
Obtain approval before furnishing annular of helical lockseam and welded seam pipe.
corrugations are more restrictive than those
Fill heights for culvert pipe with annular lockseam and welded seam pipe only.
The fill heights in the table are for helical special analysis by the CO.
METAL ROUND PIPE CULVERT
FILL HEIGHT AND METAL THICKNESS TABLE FOR HELICAL LOCKSEAM AND WELDED SEAM PIPE CULVERT
METAL PIPE ARCH CULVERT
FILL HEIGHT AND METAL THICKNESS TABLE FOR HELICAL LOCKSEAM AND WELDED SEAM PIPE CULVERT
Fill heights exceeding 30 meters require
STEEL ALUMINUM
DIAMETER
SIZE
PIPE
SPAN x RISE
SIZE
PIPE ARCH
ALUMINUMSTEEL
DIAMETER
SIZE
PIPE
SPAN x RISE
SIZE
PIPE ARCH
68 x 13 CORRUGATIONS 75 x 25 CORRUGATIONS 125 x 25 CORRUGATIONS
METAL THICKNESS
16.2
18.5
21.6
25.9
30.0
30.0
30.0
30.0
30.0
18.0
20.2
23.1
27.0
30.0
30.0
30.0
30.0
30.0
30.0
22.7
25.2
28.4
30.0
30.0
30.0
30.0
30.0
30.0
30.0
30.0
24.3
26.5
29.5
30.0
30.0
30.0
30.0
30.0
30.0
30.0
30.0
30.0
30.0
22.8
26.4
29.7
30.0
30.0
30.0
30.0
30.0
30.0
30.0
30.0
30.0
30.0
30.0
30.0
9.8
10.6
11.4
12.3
13.5
14.8
16.5
18.5
21.2
24.8
10.9
11.6
12.3
13.2
14.3
15.4
16.9
18.6
20.6
23.2
26.6
30.0
13.0
13.7
14.4
15.3
16.2
17.3
18.6
20.0
21.7
23.7
26.1
29.0
30.0
30.0
30.0
14.5
15.2
15.9
16.7
17.6
18.6
19.7
20.9
22.3
23.9
25.8
28.0
30.0
30.0
30.0
30.0
30.0
30.0
17.1
17.8
18.6
19.5
20.5
21.6
22.8
24.1
25.7
27.4
29.3
30.0
30.0
30.0
30.0
30.0
30.0
30.0
30.0
8.8
9.4
10.1
11.0
12.0
13.2
14.7
16.5
9.7
10.3
11.0
11.8
12.7
13.8
15.0
16.5
18.4
20.7
11.6
12.2
12.8
13.6
14.5
15.4
16.5
17.8
19.3
21.1
23.2
25.8
29.0
12.9
13.5
14.2
14.9
15.7
16.6
17.5
18.6
19.9
21.3
23.0
24.9
27.1
29.9
30.0
30.0
15.2
15.8
16.6
17.4
18.2
19.2
20.3
21.5
22.8
24.3
26.1
28.1
30.0
30.0
30.0
30.0
30.0
METAL THICKNESS
68 x 13 CORRUGATIONS 75 x 25 CORRUGATIONS
13.4
15.7
18.8
23.6
26.9
30.0
30.0
30.0
16.8
19.6
23.6
29.5
30.0
30.0
30.0
30.0
16.5
20.3
23.6
27.5
30.0
30.0
30.0
30.0
30.0
30.0
17.5
21.6
26.4
30.3
30.0
30.0
30.0
30.0
30.0
30.0
30.0
13.8
17.6
21.8
26.7
30.0
30.0
30.0
30.0
30.0
30.0
30.0
30.0
30.0
9.0
9.8
10.8
12.0
13.5
15.5
18.0
21.7
10.4
11.3
12.3
13.6
15.1
17.0
19.4
22.7
27.2
11.6
12.6
13.5
14.6
16.8
17.2
19.0
21.1
23.7
27.1
30.0
30.0
12.7
14.1
15.6
18.9
18.1
19.5
21.2
23.1
25.4
28.2
30.0
30.0
30.0
30.0
12.2
13.6
15.1
16.7
18.5
19.9
21.4
23.0
24.9
27.2
29.9
30.0
30.0
30.0
30.0
30.0
3.7
3.7
4.0
4.0
3.7
4.0
3.7
5.2
4.9
6.1
6.4
4.9
4.9
4.9
4.9
4.9
2620 x 1800
2410 x 1700
2210 x 1600
2060 x 1500
1850 x 1400
1680 x 1300
1630 x 1090
1520 x 1170
1450 x 970
1240 x 840
1070 x 740
890 x 610
710 x 510
610 x 460
530 x 380
430 x 330
68 x 13 CORRUGATIONS
METAL THICKNESS
75 x 25 CORRUGATIONS 125 x 25 CORRUGATIONS
4.0
3.7
4.0
3.7
4.0
3.7
5.2
5.2
5.2
5.2
68 x 13 CORRUGATIONS 75 x 25 CORRUGATIONS
METAL THICKNESS
METAL PIPE CULVERT
602-1M
8/2024
:1
A u g u s t
S td M p w w o r k \d
\S td .d g n
OFFICE OF FEDERAL LANDS HIGHWAY
U.S. DEPARTMENT OF TRANSPORTATION, FHWA
SPECIFICATION
APPROVED FOR USE
PROJECT
Roadway embankment Roadway embankment
Natural ground
Natural ground Natural ground
Roadway embankment
Roadway excavation
Natural ground
H H
H H
H H
H
H
H
Finished subgrade Finished subgrade
Natural ground
Finished subgrade before trench excavation embankment height
Finished subgrade or
Original natural ground surface
Finished subgrade
Roadway embankment
Roadway embankment
Finished subgrade trench excavations depth table
See bedding excavation in trench
HH
H
Half diameter or whichever is less
(see table)
Minimum spacing or Span
Diameter or Span
Diameter section
Metal endMetal end section or 36" (max.) for embankment installations
> 54"
12" to 54"
6"
4"
18" (min.)
* Reduce to 18" for
UP to 48"
48" and UP
24" span or 36", 18" ±
18" ±18"±
(min.)
6"
(min.)
6"
12" (min.), 24" (max.)
"/foot of cover,2 minimum
1'-0"
2H or 12' (max.)
2H or 12' (max.) 2H or 12' (max.) 2H or 12' (max.) 2H or 12' (max.)
2H or 12' (max.)2H or 12' (max.)
2H or 12' (max.) 2H or 12' (max.)
When directed, camber pipe culverts upward from a chord through the inlet and outlet inverts an ordinate amount equal to 1% of the pipe length. Develop camber on a parabolic curve. If the midpoint elevation on the parabolic curve as designed exceeds the elevation of the inlet invert, reduce the amount of camber or increase the pipe culvert gradient.
H equals the diameter of all round pipe culverts or the rise dimension of all pipe arch culverts.
See Section 704 for bedding and backfill requirements.
1.
2.
3.
Construct piping plug of impermeable backfill material at the pipe culvert inlet where granular material is used for backfill. Width may be adjusted to tie into impervious material.
MULTIPLE PIPE INSTALLATION
PIPING PLUG
BELOW NATURAL GROUND OR
TRENCH EXCAVATION IN EMBANKMENT
ON UNSTABLE MATERIAL
ABOVE AND BELOW
NATURAL GROUND
ON NATURAL GROUND
ABOVE NATURAL GROUND
ON UNYIELDING MATERIAL
PIPE BEDDING
ELEVATION
SECTION A-A
LEGEND:
Bedding material (uncompacted)
Impermeable backfill material.
BEDDING DEPTH
MINIMUM SPACING
Toe plate Toe plate
H
Width
H H
Pipe culvert
Embankment slope
High water elevation treatment
Culvert end
Piping plug
A
A
Embankment material placed in layers
Compacted backfill material placed in layers not backfill according to Section 614.
compact in layers not over compressible material. Lightly and replace with selected fine
Remove unyielding material fill material properly compacted with approved granular foundation firm bearing soil and replace
Remove unstable material to
Bedding
Bedding
Bedding
Bedding
NO SCALE
NOTE:
not exceeding 6" compacted depth.
exceeding 6" compacted depth; or lean concrete
6" in uncompacted depth.
2'-0" ±
1'-0" ±
SPACING
DIAMETER
or SPAN
PIPE SIZE (H) DEPTH
PIPE CULVERT BEDDING
METAL AND PLASTIC
602-3
FP-14
1/2024
:2
J u ly
S td p w w o r k \d
\S td f p .d g n
OFFICE OF FEDERAL LANDS HIGHWAY
U.S. DEPARTMENT OF TRANSPORTATION, FHWA
SPECIFICATION
APPROVED FOR USE
PROJECT
Roadway embankment Roadway embankment
Natural ground
Natural ground Natural ground
Roadway embankment
Roadway excavation
Natural ground
H H
H H
H H
H
H
H
Finished subgrade Finished subgrade
Natural ground
Finished subgrade before trench excavation embankment height
Finished subgrade or
Original natural ground surface
Finished subgrade
Roadway embankment
Roadway embankment
Finished subgrade trench excavations depth table
See bedding excavation in trench
HH
H
Half diameter or whichever is less
(see table)
Minimum spacing or Span
Diameter or Span
Diameter section
Metal endMetal end section
(min.)
(min.)
300 (min.), 600 (max.)
50 mm/m of cover, or 900 (max.) for embankment installations
450 (min.)
150 mm in uncompacted depth
> 1350
300 to 1350
UP to 1200
1200 and UP
* Reduce to 450 for span or 900, 450± 450± minimum
450±
Dimensions without units are millimeters.
units of measure. Metric This drawing contains
2H or 3600 (max.) 2H or 3600 (max.)2H or 3600 (max.) 2H or 3600 (max.)
2H or 3600 (max.)2H or 3600 (max.)
2H or 3600 (max.)
2H or 3600 (max.) 2H or 3600 (max.)
When directed, camber pipe culverts upward from a chord through the inlet and outlet inverts an ordinate amount equal to 1% of the pipe length. Develop camber on a parabolic curve. If the midpoint elevation on the parabolic curve as designed exceeds the elevation of the inlet invert, reduce the amount of camber or increase the pipe culvert gradient.
H equals the diameter of all round pipe culverts or the rise dimension of all pipe arch culverts.
See Section 704 for bedding and backfill requirements.
1.
2.
3.
Construct piping plug of impermeable backfill material at the pipe culvert inlet where granular material is used for backfill. Width may be adjusted to tie into impervious material.
MULTIPLE PIPE INSTALLATION
PIPING PLUG
BELOW NATURAL GROUND OR
TRENCH EXCAVATION IN EMBANKMENT
ON UNSTABLE MATERIAL
ABOVE AND BELOW
NATURAL GROUND
ON NATURAL GROUND
ABOVE NATURAL GROUND
ON UNYIELDING MATERIAL
PIPE BEDDING
ELEVATION
SECTION A-A
LEGEND:
Bedding material (uncompacted)
Impermeable backfill material.
BEDDING DEPTH
MINIMUM SPACING
Toe plate Toe plate
H
Width
H H
Pipe culvert
Embankment slope
High water elevation treatment
Culvert end
Piping plug
A
A
Embankment material placed in layers
Compacted backfill material placed in layers not backfill according to Section 614.
compact in layers not over compressible material. Lightly and replace with selected fine
Remove unyielding material fill material properly compacted with approved granular foundation firm bearing soil and replace
Remove unstable material to
Bedding
Bedding
Bedding
Bedding
NO SCALE
NOTE:
exceeding 150 mm compacted depth; or lean concrete not exceeding 150 mm compacted depth.
300±
600 ±
SPACING
DIAMETER
or SPAN
PIPE SIZE (H) DEPTH
602-3M
PIPE CULVERT BEDDING
METAL AND PLASTIC
:4
J a n u a r y
S td M p w w o r k \d
\S td S td f p .d g n
OFFICE OF FEDERAL LANDS HIGHWAY
U.S. DEPARTMENT OF TRANSPORTATION, FHWA
SPECIFICATION
APPROVED FOR USE
PROJECT
rail as applicable ground line at face of
Edge of pavement or
Lap in direction of traffic
Reflector tab
W beam rail
(See Note 5)
Block
Post length stamp on terminal sections
All posts except those beyond nut by more
Thread not to extend spacing, center to center slots
Splice bolt
Neutral axis
Splice bolt slots and departure terminal sections
Widening required for approach
Subgrade shoulder.
Hinge line of foreslope
See Note 4 to accommodate future overlays
Upper 2 holes for raising guardrail
8 required, each end of rail recess both sides groundline at face of rail
Edge of pavement or bolts and nuts (8 per splice) bolt and recess nut
STANDARD POST SECTION
POST SPACING
1:10 or flatter slope
TOP symmetry of�
FRONTSIDE
TYPICAL GUARDRAIL CROSS SECTION
SIDE
TOP
POST FACE
BLOCK
POST AND BLOCK DETAIL
ARRANGEMENT
ALTERNATE HOLE
GUARDRAIL BOLT AND RECESS NUT
GUARDRAIL MOUNT
FLEXIBLE GUIDE POST
POST AND BLOCK DETAIL
ARRANGEMENT
STANDARD HOLE
steeper than fill slope
Variable slope but not
A
�about Symmetrical
A
RAIL ELEVATION
SECTION A-A
W BEAM RAIL
shown on Typical Section
Aggregate base or as
6.
5.
4.
3.
2.
1.
practices.
including its appearance, and accepted manufacturing be those consistent with the proper functioning of the part, Dimensional tolerances not shown or implied are intended to consistent material throughout the length of guardrail run.
Block may be wood, plastic, or composite material. Use may be used if approved.
specified by the manufacturer. Alternate delineator types washer on both sides, a lock washer, and nut; or fasten as
Install delineator every fourth post. Fasten delineator to arrangement is specified.
See Special Contract Requirements when the alternate hole longer posts are specified.
When encountering impenetrable material, see
S e e N o te
L e n g th
L
(STANDARD HOLE ARRANGEMENT)
STRUCTURAL SHAPE POST
reflective sheeting Top edge of yellow to left of traffic)
(white to right of traffic, Reflective sheeting
10°
Thickness
Sheet o r g ro u n d l in e o f p a v e m e n t a b o v e t ra v e le d w a y e d
Traffic
Variablefill slope
"32
"16
"32
" splice bolt slot.8 1" x 132
" post bolt slot at 6'-3"2 1" x 24
" GUARDRAIL BOLT8
" RECESS NUT8
6"
"4
"4
"4
6'-0"
" high (typ.)2
" plain round washer.4
" recess nut.8
"2 1than
" R16
"32
"4 to e d g
W6 x 9
" x 10" guardrail post bolt8
" dia. (typ.)4
" x 10" guardrail bolt8
" bolts with a 8 3post using two galvanized 2" x
"4 14"4
142"
" deep16 11" dia. x
(ty p.)
6"
(t y p
(t y p
S e e N o te
(t y p
6"
" dia4
" dia.4
"16 1"16
(m in
(t y p
" x 10" guardrail8
See Note 2
2'-0" (typ.)
" guardrail splice4 1" x 18
5 "16
"32
"4
"16
"8
"16
8"
Post spacing 6'-3"
(typ.)
8"
" R16
See Special Contract Requirements when 7 foot or
Standard 617-13.
L Thread Length
NOTE:
NO SCALE
"4
25"
18"
10"
2"
" minimum8
" minimum4
4" minimum
4" minimum
4" minimum
STEEL POSTS
G4 W-BEAM GUARDRAIL
617-11
:1
J u ly
S td
-1 p w
-w o rk \d
\S td
-1 fp
.d g n
OFFICE OF FEDERAL LANDS HIGHWAY
U.S. DEPARTMENT OF TRANSPORTATION, FHWA
SPECIFICATION
APPROVED FOR USE
PROJECT
rail as applicable ground line at face of
Edge of pavement or
Lap in direction of traffic
Reflector tab
W beam rail
(See Note 5)
Block
Post length stamp on terminal sections
All posts except those beyond nut by more
Thread not to extend spacing, center to center slots
Splice bolt
Neutral axis
Splice bolt slots and departure terminal sections
Widening required for approach
Subgrade shoulder.
Hinge line of foreslope
See Note 4 to accommodate future overlays
Upper 2 holes for raising guardrail
8 required, each end of rail recess both sides groundline at face of rail
Edge of pavement or bolts and nuts (8 per splice)
Dimensions without units are millimeters.
units of measure. Metric This drawing contains bolt and recess nut
STANDARD POST SECTION
POST SPACING
1:10 or flatter slope
TOP symmetry of�
FRONTSIDE
TYPICAL GUARDRAIL CROSS SECTION
SIDE
TOP
POST FACE
BLOCK
POST AND BLOCK DETAIL
ARRANGEMENT
ALTERNATE HOLE
GUARDRAIL BOLT AND RECESS NUT
GUARDRAIL MOUNT
FLEXIBLE GUIDE POST
POST AND BLOCK DETAIL
ARRANGEMENT
STANDARD HOLE
steeper than fill slope
Variable slope but not
A
�about Symmetrical
A
RAIL ELEVATION
SECTION A-A
W BEAM RAIL
shown on Typical Section
Aggregate base or as
6.
5.
4.
3.
2.
1.
practices.
including its appearance, and accepted manufacturing be those consistent with the proper functioning of the part, Dimensional tolerances not shown or implied are intended to consistent material throughout the length of guardrail run.
Block may be wood, plastic, or composite material. Use may be used if approved.
specified by the manufacturer. Alternate delineator types washer on both sides, a lock washer, and nut; or fasten as
Install delineator every fourth post. Fasten delineator to arrangement is specified.
See Special Contract Requirements when the alternate hole longer posts are specified.
When encountering impenetrable material, see
S e e N o te
L e n g th
L
(STANDARD HOLE ARRANGEMENT)
STRUCTURAL SHAPE POST
reflective sheeting Top edge of yellow to left of traffic)
(white to right of traffic, Reflective sheeting
10°
Thickness
Sheet o r g ro u n d l in e o f p a v e m e n t a b o v e t ra v e le d w a y e d
Traffic
Variablefill slope
See Special Contract Requirements when 2 m or
Standard M617-13.
unavailable.
US Customary sizes may be used when metric sizes are Furnish hardware in the metric sizes shown. Equivalent
M15 RECESS NUTM15 GUARDRAIL BOLT
24 x 30 splice bolt slot.
20 x 65 post bolt slot at 1.905 m
24 R
38 high (typ.)
M44 plain round washer than 13 mm
M15 recess nut
1.8
10810850
Post spacing 1905 t o e d g
M15 x 255 guardrail post bolt post using two galvanized 50 mm x 9.5 mm bolts with a
19 dia. (typ.)
(m in
S e e N o te
.8 m ty p
25 dia. x 1.5 deep
17.532
.1 m
.3 m
19 dia.
19 dia.
W150 x 13.5
5.5
(t y p
M15 x 32 guardrail splice
M15 x 255 guardrail
See Note 2
610 (typ.)
M15 x 255 guardrail post bolt
(ty p.)
(typ.)
24 R
(t y p
(t y p
7.
L Thread Length
NOTE:
NO SCALE
100 minimum
100 minimum
100 minimum
45 minimum
30 minimum
STEEL POSTS
G4 W-BEAM GUARDRAIL
617-11M
:0
J u ly
S td M
-1 p w
-w o rk \d
\S td
-1 fp
.d g n
OFFICE OF FEDERAL LANDS HIGHWAY
U.S. DEPARTMENT OF TRANSPORTATION, FHWA
SPECIFICATION
APPROVED FOR USE
PROJECT
6.
5.
4.
3.
2.
1.
embankment
Edge of widened post section. See Note 4 face of the rail in the standard
Tangent line projected from the embankment
Edge of widened post section. See Note 4 face of the rail in the standard
Tangent line projected from the
Varies by manufacturer end of terminal not shown.
Terminal posts and
Varies by manufacturer end of terminal not shown.
Terminal posts and terminal grading extents where practical.
Construct a 1V:4H slope outside of the guardrail terminal.
Install a reflectorized object marker on the end of the according to the manufacturer's recommendations.
end farther from the edge of shoulder, or use a taper
Install terminal at a 1:25 taper or flatter to position the the manufacturer's recommendations.
necessary to install the tangent terminal according to manufacturer for a specific product. Adjust grading as begin at post 3. Verify the length of need with the
For design purposes, the length of need is assumed to of site limitations, use the alternative grading layout.
as practical within site constraints. If necessary because are provided, use the preferred grading layout as much staking notes or model. If no staking notes or model
Construct the terminal grading layout as shown in the other details.
recommendations. See manufacturer's drawings for
Install tangent terminal according to the manufacturer's
See Note 6
Guardrail terminal grading o r f la tt e r
V
:1 H
Front of rail face
PLAN
PREFERRED GRADING
Post section
Standard
L
See Note 6
Guardrail terminal grading o r f la tt e r
V
:1
H
Hinge point line
See Note 3
Length of Need
Guardrail system
Pay limits
Pay limits terminal section type tangent or type MGS tangent
Back of post
Back of post
Front of rail face
Hinge point line
PLAN
ALTERNATIVE GRADING
post section
See Note 3
Length of Need
12'-6"
(min.)
10'-0" m in m in m in
12'-6" m in
TEST LEVEL
L
NOTE:
NO SCALE
50 (for MGS)
37.5 or 50 (for G4)
(FT)
3 (> 45 mph)
2 (≤ 45 mph)
AND GRADING
TYPE TANGENT TERMINAL
W-BEAM GUARDRAIL
MGS AND G4
617-20
:2
J u ly
S td
-2 p w
-w o rk \d
\S td
-2 fp
.d g n
OFFICE OF FEDERAL LANDS HIGHWAY
U.S. DEPARTMENT OF TRANSPORTATION, FHWA
SPECIFICATION
APPROVED FOR USE
PROJECT
6.
4.
3.
2.
1.
embankment
Edge of widened post section. See Note 4 face of the rail in the standard
Tangent line projected from the embankment
Edge of widened post section. See Note 4 face of the rail in the standard
Tangent line projected from the
Varies by manufacturer end of terminal not shown.
Terminal posts and
Varies by manufacturer end of terminal not shown.
Terminal posts and
Dimensions without units are millimeters.
units of measure. Metric This drawing contains terminal grading extents where practical.
Construct a 1V:4H slope outside of the guardrail terminal.
Install a reflectorized object marker on the end of the according to the manufacturer's recommendations.
end farther from the edge of shoulder, or use a taper
Install terminal at a 1:25 taper or flatter to position the the manufacturer's recommendations.
necessary to install the tangent terminal according to manufacturer for a specific product. Adjust grading as begin at post 3. Verify the length of need with the
For design purposes, the length of need is assumed to of site limitations, use the alternative grading layout.
as practical within site constraints. If necessary because are provided, use the preferred grading layout as much staking notes or model. If no staking notes or model
Construct the terminal grading layout as shown in the other details.
recommendations. See manufacturer's drawings for
Install tangent terminal according to the manufacturer's
See Note 6
Guardrail terminal grading o r f la tt e r
V
:1 H
Front of rail face
PLAN
PREFERRED GRADING
Post section
See Note 6
Guardrail terminal grading o r f la tt e r
V
:1
H
Hinge point line
See Note 3
Length of Need
Back of post
Back of post
Front of rail face
Hinge point line
PLAN
ALTERNATIVE GRADING
post section
See Note 3
Length of Need
3.81 m m in
.5 m m in
(min.)
3.05 m
3.81 m m in m in
TEST LEVEL
L
NOTE:
NO SCALE
3 (> 72 km/h)
2 (≤ 72 km/h)
15.24 (for MGS)
11.43 or 15.24 (for G4)
7.62
(m)
617-20M
:1
J u ly
S td M
-2 p w
-w o rk \d
\S td
-2 fp
.d g n
OFFICE OF FEDERAL LANDS HIGHWAY
U.S. DEPARTMENT OF TRANSPORTATION, FHWA
SPECIFICATION
APPROVED FOR USE
AND GRADING
TYPE TANGENT TERMINAL
W-BEAM GUARDRAIL
MGS AND G4
PROJECT
4.
3.
2.
1.
15°
CRT POST DETAIL
See Note 1
POSTS #3 - #7
PLAN
Secondary Roadway or Driveway
M a in li n e R o a d w a y
PC
PT
5 4 3 2 1
1V:10H bolt (no rail washer) shown on Typical Section
Aggregate base or as and accepted manufacturing practices.
functioning of the part, including its appearance, intended to be those consistent with the proper
Dimensional tolerances not shown or implied are between Posts 7 and 8.
Post 8, add a standard post and block midway
If the CRG will be connected to transition rail at terminal on all other roadway approaches.
road approaches. Use the appropriate TL-2 or TL-3 driveways, service roads, and low speed minor
The use of the Type CRT terminal is limited to
Do not use this layout when speeds are in excess and PT, plus the post with block at Post #7.
CRT posts include those posts between the terminal
Terminal sectionPay Limits Guardrail system CRG s ta n d a r d p o s t s e c ti o n
G
W B e a m g u a r d r il e e t a b le
L groundline at face of rail
Edge of pavement or steeper than fill slope
Variable slope but not
Hinge line of foreslope to W-beam for
Do not bolt post
Hinge line of foreslope
(See table)
W
See Note 4
See Note 1.
CRT post with blockout
WITH CRT POSTS
GUARDRAIL SYSTEM CRG
ELEVATION
5 4 3 2 1
Terminal Section
Pay Limits
Pay Limits Guardrail System CRG at face of rail as applicable
Edge of pavement or ground line
See Note 3
TYPICAL GUARDRAIL CROSS SECTION
terminal sections approach and departure
Widening required for
Subgrade shoulder.
CRT posts
15°
Ra di us
2'-0"
25' (min.) from PC to Post 1 using 6'-0" posts
8'-6" radius
@ 6'-3" spacing with no rail washers
" dia. hole4
8"" dia. x 10" guardrail8
2'-0" (typ.)
4"
See Standard 617-22 for terminal section shown.
of 45 mph.
" dia. holes2
105°
90°
75°
105°
90°
75°
90°-105°
75°-90°
90°-105°
75°-90°
1V:2H to 1V:6H
ANGLE
FIXED OBJECTS
AREA FREE OF
(See Note 1)
CRT POSTS
NUMBER OF
PC AND PT
BETWEEN
CURVATURE
POSTS ALONG
NUMBER OF
L W o r c o n n e c ti o n t o s tr u c tu r e
RADIUS
NOTE:
NO SCALE
17'-0"
8'-6"
35'-0"
25'-6"
(ft)
:5
J u ly
S td p w w o r k
\d
\S td f p
.d g n
OFFICE OF FEDERAL LANDS HIGHWAY
U.S. DEPARTMENT OF TRANSPORTATION, FHWA
SPECIFICATION
APPROVED FOR USE
WOOD POSTS
CRG W-BEAM GUARDRAIL
617-21
PROJECT
4.
3.
2.
1.
15°
89 dia. holes
19 dia. holes
Dimensions without units are millimeters.
units of measure. Metric This drawing contains
CRT POST DETAIL
See Note 1
POSTS #3 - #7
PLAN
Secondary Roadway or Driveway
M a in li n e R o a d w a y
PC
PT
5 4 3 2 1
1V:10H bolt (no rail washer) shown on Typical Section
Aggregate base or as and accepted manufacturing practices.
functioning of the part, including its appearance, intended to be those consistent with the proper
Dimensional tolerances not shown or implied are between Posts 7 and 8.
Post 8, add a standard post and block midway
If the CRG will be connected to transition rail at terminal on all other roadway approaches.
road approaches. Use the appropriate TL-2 or TL-3 driveways, service roads, and low speed minor
The use of the Type CRT terminal is limited to
Do not use this layout when speeds are in excess and PT, plus the post with block at Post #7.
CRT posts include those posts between the terminal
Terminal sectionPay Limits Guardrail system CRG s ta n d a r d p o s t s e c ti o n
G
W B e a m g u a r d r il e e t a b le
L groundline at face of rail
Edge of pavement or steeper than fill slope
Variable slope but not
Hinge line of foreslope to W-beam for
Do not bolt post
Hinge line of foreslope
(See table)
W
See Note 4
See Note 1.
CRT post with blockout
WITH CRT POSTS
GUARDRAIL SYSTEM CRG
ELEVATION
5 4 3 2 1
Terminal Section
Pay Limits
Pay Limits Guardrail System CRG at face of rail as applicable
Edge of pavement or ground line
See Note 3
TYPICAL GUARDRAIL CROSS SECTION
terminal sections approach and departure
Widening required for
Subgrade shoulder.
CRT posts
15°
Ra di us
2590 radius using 1829 posts
7620 (min.) from PC to Post 1
See Standard M617-22 for terminal section shown.
of 72 km/h.
610 (typ.)
@ 1905 spacing with no rail washers
M16 x 255 guardrail
105°
90°
75°
105°
90°
75°
90°-105°
75°-90°
90°-105°
75°-90°
1V:2H to 1V:6H
ANGLE
FIXED OBJECTS
AREA FREE OF
(See Note 1)
CRT POSTS
NUMBER OF
PC AND PT
BETWEEN
CURVATURE
POSTS ALONG
NUMBER OF
L W o r c o n n e c ti o n t o s tr u c tu r e
RADIUS
NOTE:
NO SCALE
(m)
10668
WOOD POSTS
CRG W-BEAM GUARDRAIL
617-21M
:4
J u ly
S td
M p w w o r k
\d
\S td f p
.d g n
OFFICE OF FEDERAL LANDS HIGHWAY
U.S. DEPARTMENT OF TRANSPORTATION, FHWA
SPECIFICATION
APPROVED FOR USE
PROJECT
13°
30°
" splice bolt slot8
" x 116
1" hex bolt and nut
Terminal post threaded full length galvanized structural tube
Steel tube anchor
PLAN
DETAIL B
DETAIL A
PLAN
ELEVATION
BUFFERED END SECTION
2.
1.
steel plate
40 galvanized steel pipe
Terminal post
See Detail A
Terminal connector (adjust to fit)
Buffered End Sectioncable with one swaged end
Do not connect to post and recess nut with no washer
Attach W beam to pipe with hole to tubular steel
RIGHT SIDEFRONT
POST ASSEMBLY
DETAIL C
galvanized nails bent over
Two 16d common nut with 2 washers each and steel washer
Cable assembly
Post sleeve
Bearing plate
Ground line plate to prevent rotation
Steel tube anchor
Bearing plate
Steel tube anchor
Guardrail System CRG Pay limits and washer
See Detail C
2 washers each bolt & nut with Soil plate (typ.)
nut with 2 washers each
ANCHORAGE ASSEMBLY
ELEVATION
Terminal post (typ.)Ground line
See Note 1
CRT Post
See Detail B
Post sleeve
Bearing plate anchor
Steel tube
(6 required) nuts with 2 washers each anchor bracket and
Anchor plate with practices.
part, including its appearance, and accepted manufacturing to be those consistent with the proper functioning of the
Dimensional tolerances not shown or implied are intended steel plate washer and
Attach terminal connector
See Standard 617-21 and 617-23 for other details.
R
" x 4" x 12"4
10" OD schedule
" dia. hole4
" x 8"4
" x 2
" x 22
1" dia. nut
1" x 4" stud
"4
" x 2
" x 22
Tack weld 2
" dia. (6x19) x 9'-0"4
"4
" x 2
" x 22
W beam w/ 2 " x 2" guardrail bolt8
6'-3"6'-3" eight 1" dia. hex bolts and 16"12" 18"
"2
" cable clips4
" hex bolt and8
" x 98
" x 8" hex8
1" hex nut
" x 10" hex bolt and 8
1" H.S. hex nut
" dia. hole8
4"
4 " max.
" nom.2 ty p
" dia.16 steel plate with 1
2" "2
8 "2
NOTE:
NO SCALE
:4
J u ly
S td p w w o r k
\d
\S td
.d g n
OFFICE OF FEDERAL LANDS HIGHWAY
U.S. DEPARTMENT OF TRANSPORTATION, FHWA
SPECIFICATION
APPROVED FOR USE
TYPE G4-CRT
CABLE RELEASING TERMINAL
G4 W-BEAM GUARDRAIL
617-22
PROJECT
30°
25 dia. nut
19 dia. hole
24 x 29 Splice bolt slot
25 hex bolt and nut
16 x 200 Hex
60 dia. hole
16 x 254 Hex volt and
Dimensions without units are millimeters.
units of measure. Metric This drawing contains
Terminal post threaded full length galvanized structural tube
Steel tube anchor
PLAN
DETAIL B
DETAIL A
PLAN
ELEVATION
BUFFERED END SECTION
2.
1.
steel plate
40 galvanized steel pipe
Terminal post
See Detail A
Terminal connector (adjust to fit)
Buffered End Sectioncable with one swaged end
Do not connect to post and recess nut with no washer
Attach W beam to pipe with hole to tubular steel
RIGHT SIDEFRONT
POST ASSEMBLY
DETAIL C
galvanized nails bent over
Two 16d common nut with 2 washers each and steel washer
Cable assembly
Post sleeve
Bearing plate
Ground line plate to prevent rotation
Steel tube anchor
Bearing plate
Steel tube anchor
Guardrail System CRG Pay limits and washer
See Detail C
2 washers each bolt & nut with Soil plate (typ.)
nut with 2 washers each
ANCHORAGE ASSEMBLY
ELEVATION
Terminal post (typ.)Ground line
See Note 1
CRT Post
See Detail B
Post sleeve
Bearing plate anchor
Steel tube
(6 required) nuts with 2 washers each anchor bracket and
Anchor plate with practices.
part, including its appearance, and accepted manufacturing to be those consistent with the proper functioning of the
Dimensional tolerances not shown or implied are intended steel plate washer and
Attach terminal connector
64 x 64 x 6 x 200
25 x 100 stud steel plate with 27 dia.
Tack weld 64 x 64 x 6
19 x 100 x 300
254 OD schedule
19 dia. (150 x 483) x 2743
191 x 50 guardrail bolt W beam w/64 x 64 x 6
405305
19051905 eight 25 dia. hex bolts and
19 Cable clips
25 Hex nut
16 x 251 Hex bolt and
25 H.S. hex nut
216 19151
See Standard M617-21 and M617-23 for details.
R
6 6
114 (max.)
89 (nom.)
ty p
NOTE:
NO SCALE
617-22M
:3
J u ly
S td
M p w w o r k
\d
\S td
.d g n
OFFICE OF FEDERAL LANDS HIGHWAY
U.S. DEPARTMENT OF TRANSPORTATION, FHWA
SPECIFICATION
APPROVED FOR USE
TYPE G4-CRT
CABLE RELEASING TERMINAL
G4 W-BEAM GUARDRAIL
PROJECT
NO SCALE
POST AND GEOTEXTILE INSTALLATION DETAIL
SILT FENCE INSTALLATION AT TOE OF FILL
Fi ll slo pe
T o e o f s lo p e
PLAN
ELEVATION
4.
3.
2.
1.
T o e o f s lo p e
Fi ll sl op e
ELEVATION
PLAN
PLAN
PLAN
END DETAIL
END POSTS DETAIL
POSTS AT JOINTS
Varies
Varies
Geotextile
Steel or wood post
Backfilled and compacted soil f o r s p a c in g
S e e N o te
Limits of clearing
(undisturbed)
Existing ground
Silt fence reinforcement
NOTE:
Staple or tie
Section B
Geotextile fabric, Tie top of posts together driven tightly together.
Steel or wood posts
Steel or wood post
Staple or tie
Geotextile fabric
Fasten fabric to posts around each post one full turn.
Fold geotextile fabric See Note 3
End Posts Detail
End posts, see
End Posts Detail
End posts, see
See Note 3 fabric, Section A
Geotextile
Flow
Flow
Flow running around the ends.
Curve ends of silt fence upgrade to prevent water from as possible.
Install silt fence to follow the ground contours as closely does not slide down, supporting posts.
All types must ensure silt fence remains attached to, and manufacturer's recommendations for installation procedures.
as long as specified dimensions are satisfied. Follow
Alternate preassembled silt fence options will be allowed m in m in m in
6-foot (max.) spacing without silt fence reinforcement.
10-foot (max.) spacing with silt fence reinforcement.
4" min.
6" min. trench
DETAIL APPROVED FOR USE 10/2016
REVISED:
157-1W
WFLHD DETAIL
SILT FENCE8
:3
A
M
F e b r u a r y
D e t
W c p w w o r k
\d
\W
.d g n
DETAIL
OFFICE OF FEDERAL LANDS HIGHWAY
FEDERAL HIGHWAY ADMINISTRATION
U.S. DEPARTMENT OF TRANSPORTATION
PROJECT
NO SCALE
Spacing Slope
STAKES REQUIRED
1:1
1:2
1:3
1:4 or flatter for each roll
Stakes required
FIBER ROLL SPACING
Fiber roll length
Fl ow
T o e o f fi ll s lo p e
ELEVATION
PLAN
disturbed areas
Runoff from
INSTALLATION BEYOND TOE OF SLOPE
INSTALLATION ALONG SLOPES
FIBER ROLL STAKING DETAIL
PROPERLY STAKED AND ENTRENCHED FIBER ROLL
Existing ground (typ.)
Fiber roll
Flow direction
Slope
Direction ofrunoff from disturbed areas sp ac in g ch ar t
S ee
Fi be r
R ol l
Fiber roll ff o n ur f o n oi t c er i
D along contours
Install fiber rolls
Fiber roll
Slope
Fi ll slo pe
Direction of runoff ground
Existing soil to match ground level
Backfilled and compacted
Flow larger than fiber roll wood stakes. See Note 2.
Pay lim its
Pay lim its
SLOPE PROTECTION INSTALLATION
ALTERNATE FIBER ROLL JOINT DETAIL
FIBER ROLL LAPPING DETAIL
on uphill side of fiber roll
Place excavated materialStagger joints (typ.)
2.
1.
permanent installations. Do not crush fiber roll while staking.
roll is secure to slope. Live stakes may be used for and install fiber rolls
Step 1: Excavate trench Step 2: Backfill soil against fiber rolls
FIBER ROLL
(FT)
(FT)
2" (min.) Excavate trench 2"
1" x 1" or 1" Ø ove rlap
12" (m in.)
t o m in m in
1" x 1" Wood stake as specified in plans
3' min. or
3' (min.)
Drive stakes at each end and at 4-foot spacing until fiber fiber roll and space stakes at 4-foot max.
6-inches from fiber roll end angles towards the adjacent
Overlap fiber rolls 12-inch minimum. Drive stakes at
NOTE:
WFLHD DETAIL
DETAIL APPROVED FOR USE 10/2014
7/2016REVISED:
157-21W
:2
A
M
F e b r u a r y
D e t
W c p w w o r k
\d
\W
.d g n
DETAIL
OFFICE OF FEDERAL LANDS HIGHWAY
FEDERAL HIGHWAY ADMINISTRATION
U.S. DEPARTMENT OF TRANSPORTATION
PROJECT
Bottom of sign single post installations of post. Omit notch for
Saw cut notch full width post�
See table for hole size post, parallel to sign face.
Field drill holes through
Backfill material
Same post size
Same post size
Same post size
Backfill material
Backfill material
Backfill material
" lock nut16
" oversized washer16
" outside dia.)4 1(1 " bolt16
" bolt thru the post8
NO SCALE
NOTE:
multiple sign installations.
- Dimensions of a rectangle enclosing all the signs for to back signs
- Overall dimensions of the sign for a single sign, or back For the purpose of post selection X and Y are as follows:
longest post.
Z is the height from ground line to mid-height of sign at the conditions. See Wood Post Selection Table below.
D is the minimum post embedment depth for average soil to fit field conditions.
clear zone.
post is vulnerable to being struck when placed outside the
Provide traffic barrier protection for all posts larger than
5.
4.
3.
2.
1.
oversized washer
POST DETAIL
SINGLE POST SIGNS TWO POST SIGNS
SIGNS WITHOUT ANGLES
TYPICAL MOUNTING FOR
FOUR POST SIGNSTHREE POST SIGNS
SIGN INSTALLATION ANGLE
Direction of traffic flow
Long side of post
(See Post Selection table)
Notch depth (where required)
Finish ground line
W
Y V
.5
Y
Z ty p
D
H
E d g e o f s h o u ld e r
E d g e o f tr a v e le d w a y of traveled way
Elevation at edge
E d g e o f s h o u ld e r
E d g e o f tr a v e le d w a y
W of traveled way
Elevation at edge of traveled way
Elevation at edge of traveled way
Elevation at edge
E d g e o f s h o u ld e r
E d g e o f s h o u ld e r
E d g e o f tr a v e le d w a y
E d g e o f tr a v e le d w a y
Y V
0.6X0.2X 0.2X
H 2
H
.5
Y
Z ty p
D
V
0.15X0.35X0.35X0.15X
Y
Z ty p
D
H ty p
D
H
W
W
V Y
H
H
0.125X0.25X0.25X0.25X0.125X
.5
Y Z
H2
H
H
MINIMUM DISTANCE TO SIGN
Location
WOOD POST SELECTION TABLE
SIZE
POST
a secondary sign mounted below another sign.
exceeds the limit for the largest post, use steel post installation.
Values shown are the maximum permitted. If the product of XYZ indicate overall post length. Select post lengths4 thru H1
H
6 x 8 inches when located within the clear zone or if the
" nonmetalic 16
For all retroflectorized signs where W > 25' to 12' max
X = 4' min
V may be reduced by 1 foot in rural districts for all around (typ)
3" minimum all around (typ)
3" minimum all around (typ)
3" minimum all around (typ)
3" minimum to 22' max
X = 14' min to 18' max
X = 10' min max
X = 5'
Offset (W) Lateral
Height (V) Mounting
Rural Districts
Residence Districts Business or from curb
NUMBER OF POSTS
1 2 3 4 D diameter and hole
Notch depth
2 ft
6 ft
7 ft
5 ft
6'-0"
5'-0"
5'-0"
4'-0"
4'-0"
4'-0"
3'-0"
8 x 12
8 x 10
6 x 10
6 x 8
6 x 6
4 x 6
4 x 4
Product of X-Y-Z in CUFT(inch)
"4
"4
"2
WOOD POSTS
INSTALLATION
PERMANENT SIGN
633-7W
9/2024
:3
S e p te m b e r
D e t W
-7 p w
-w o rk
\d m s \W
-7
.d g n
OFFICE OF FEDERAL LANDS HIGHWAY
U.S. DEPARTMENT OF TRANSPORTATION, FHWA
SPECIFICATION
APPROVED FOR USE
PROJECT
Bottom of sign single post installations of post. Omit notch for
Saw cut notch full width post�
See table for hole size post, parallel to sign face.
Field drill holes through
Backfill material
Same post size
Same post size
Same post size
Backfill material
Backfill material
Backfill material Dimensions without units are millimeters.
units of measure. Metric This drawing contains
NO SCALE
NOTE:
multiple sign installations.
- Dimensions of a rectangle enclosing all the signs for to back signs
- Overall dimensions of the sign for a single sign, or back For the purpose of post selection X and Y are as follows:
longest post.
Z is the height from ground line to mid-height of sign at the conditions. See Wood Post Selection Table below.
D is the minimum post embedment depth for average soil to fit field conditions.
clear zone.
post is vulnerable to being struck when placed outside the
Provide traffic barrier protection for all posts larger than
5.
4.
3.
2.
1.
oversized washer
POST DETAIL
SINGLE POST SIGNS TWO POST SIGNS
SIGNS WITHOUT ANGLES
TYPICAL MOUNTING FOR
FOUR POST SIGNSTHREE POST SIGNS
SIGN INSTALLATION ANGLE
Direction of traffic flow
Long side of post
(See Post Selection table)
Notch depth (where required)
Finish ground line
W
V
Y
Z ty p
D
H
E d g e o f s h o u ld e r
E d g e o f tr a v e le d w a y of traveled way
Elevation at edge
E d g e o f s h o u ld e r
E d g e o f tr a v e le d w a y
W of traveled way
Elevation at edge of traveled way
Elevation at edge of traveled way
Elevation at edge
E d g e o f s h o u ld e r
E d g e o f s h o u ld e r
E d g e o f tr a v e le d w a y
E d g e o f tr a v e le d w a y
Y V
0.6X0.2X 0.2X
H 2
H
.5
Y
Z ty p
D
V
0.15X0.35X0.35X0.15X
Y
Z ty p
D
H ty p
D
H
W
W
V Y
H
H
0.125X0.25X0.25X0.25X0.125X
.5
Y Z
H2
H
H
MINIMUM DISTANCE TO SIGN
Location
WOOD POST SELECTION TABLE
SIZE
POST
a secondary sign mounted below another sign.
exceeds the limit for the largest post, use steel post installation.
Values shown are the maximum permitted. If the product of XYZ indicate overall post length. Select post lengths4 thru H1
H
150 x 200 mm when located within the clear zone or if the max
X = 1.5 m to 3.6 m max
X = 1.2 m min all around (typ)
76 minimum M8 lock nut
8 mm oversized washer
(32 mm outside dia.)
8 mm nonmetalic
M8 bolt all around (typ)
76 minimum to 6.6 m max
X = 4.2 m min all around (typ)
76 minimum all around (typ)
76 minimum to 5.4 m max
X = 3.0 m min
M8 bolt thru the post
V may be reduced by 0.3 m in rural districts forFor all retroflectorized signs where W > 7.6 m
Offset (W) Lateral
Height (V) Mounting
Rural Districts
Residence Districts Business or from curb
NUMBER OF POSTS
1 2 3 4 D diameter and hole
Notch depth
0.6 m
1.8 m
2.1 m
1.5 m
(mm) Product of X-Y-Z (m3) (m)
200 x 300
200 x 250
150 x 250
150 x 200
150 x 150
100 x 150
100 x 100
21.7
16.1
10.8
8.4
6.6
5.0
2.2
64.7
45.1
33.0
23.8
13.3
10.8
4.3
97.0
67.5
49.6
35.8
19.9
15.3
6.6
129.4
90.0
66.1
47.6
26.6
20.3
18.7
1.8
1.5
1.5
1.2
1.2
1.2
0.9
65 mm
45 mm
45 mm
WOOD POSTS
INSTALLATION
PERMANENT SIGN
633-7WM
9/2024
:1
S e p te m b e r
D e t W
M
-7 p w
-w o rk \d
\W
-7
.d g n
OFFICE OF FEDERAL LANDS HIGHWAY
U.S. DEPARTMENT OF TRANSPORTATION, FHWA
SPECIFICATION
APPROVED FOR USE
PROJECT
| Proj-Num: |
| NPS: |
| 602-1: |
| M602-1: |
| Proj-Num#1: |
| NPS#1: |
| 602-3: |
| M602-3: |
| Proj-Num#2: |
| NPS#2: |
| 617-11: |
| M617-11: |
| Proj-Num#3: |
| NPS#3: |
| 617-20: |
| M617-20: |
| Proj-Num#4: |
| NPS#4: |
| M617-21: |
| 617-21: |
| Proj-Num#5: |
| NPS#5: |
| 617-22: |
| M617-22: |
| NPS#6: |
| Proj-Num#6: |
| W157-1: |
| NPS#7: |
| Proj-Num#7: |
| W157-21: |
| Proj-Num#8: |
| NPS#8: |
| W633-7: |
| WM633-7: |