Government_Responses_to_Vendor_Questions_0001.pdf
PDF 429 KB Posted
- Attached to
- Mary Fire Temp Fence Construction
- Solicitation number
- 140L2625Q0020
About this file
This document is a Contractor Questions and Government Responses file for the Mary Fire Temp Fence Construction federal contract (Solicitation Number 140L2625Q0020). The file contains 11 questions and corresponding government responses regarding fence construction details, with key clarifications including:
The project involves a total small business set-aside for installing all-new fencing in Idaho, with government-supplied materials. Specific technical details were addressed, such as wire gauge specifications (9 or 12.5 gauge), wire spacing measurements (top wire at 40", middle at 28", bottom at 18"), and site preparation requirements. The government confirmed the project is for complete new fence construction, not a repair, with a 45-calendar day performance period. Contractors are required to provide installation services only, with the government supplying all fence materials. Additional clarifications covered equipment needs (a chainsaw would be sufficient for brush clearing) and confirmed no specific socioeconomic business ownership classification is required beyond the small business set-aside.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Question Government response Reference
A rigid steel strap or 9-gauge smooth wire loop 6 inches from the ground securely connected to the gate post and shaped so the gate stay will be securely held in place. Sheet 16 of 23, Metal Prefabricated Fence Panels, detail "Typical Gate Installation" shows the wire loop to be gauge
12.5. Please clarify is the wire loops should be 12.5 gauge or 9 gauge?
Wire for ties, gate loops and fastening wood stays shall be 9 or 12-1/2 gauge galvanized wire as specified (Section 02824 Part 2.1.F) SECTION 02824 Part 2, E.1
2 SPACING BETWEEN WIRES. What spacing does the government specify between the wires? Wire location/dimensions in inches from ground: Top = 40", Middle = 28", Bottom = 18" Page 11, Sheet 1, Note 1.E.
Does the Mary Fire Temp Fence Construction project require an ownership classification (eg.
women owned or disabled veteran owned business) status?
The requirement is being set aside for total small business, not any specific socioeconomic category.
4 Is this more of a fence repair and replace or is this all new build? All new build 5 Is there an existing fence or portions of an existing fence that will need to be removed? No 6 Would a chainsaw be sufficient for clearing the 1,020 ft of brush or is larger equipment needed? Chainsaw would likely be sufficient. See Solicitation attachement Project Site Photos (Image 5).
section B item 1 it states that the contractor is to supply materials. in section B 01009 it states in two places that the government will be supplying the materials. Which is correct? The Government is supplying the materials identified in B 01009. Section B- Pricing schedule updated. Pricing Schedule
I also see in one list of materials needed it doesn't mention wire stays, in the other list saying that the government will provide the materials, it shows around 2800 wire stays can you clarify that as well? Installation of wire stays will not be required. Section 01019 Part 2.1.A Wire Stays 36" 2693 EACH
9 Please confirm this project is for all new fencing.
Project is for the installation of all new fencing with Government supplied fence materials (Attachement 1- Section 01019 Part 2.1.A)
10 Can the period of performance be extended to 90 days? No
Bid form requires uniting pricing for fencing materials. Solicitation states all materials are provided. Please clarify that the unit pricing speed sheet is for install only. Unit pricing is for installation only.
Contractor Questions and Government responses: Mary Fire Temp Fence Construction (140L2625Q0020)