E-101_-_Updated_09-05-25_0002.pdf
PDF 174 KB Posted
- Attached to
- BLM-CO TRFO CANM LAKEVIEW INTERN HOUSING
- Solicitation number
- 140L1725R0003
About this file
This document is an electrical power plan schematic for a building, specifically drawing E-101, dated 9/5/2025. The plan details a comprehensive electrical upgrade involving the installation of a new NEMA 3R, 200A exterior panel and refeed of an existing panel. Key electrical modifications include installing a GFCI outlet in a cabinet above a microwave, with the drawing providing a detailed floor plan layout showing outlet and panel locations.
The document includes a general notes section with technical specifications for electrical installations, such as routing guidelines, panel enclosure requirements, and wiring instructions. An electrical fixture schedule is also present, indicating specific electrical components and their quantities. The drawing is marked "NOT FOR CONSTRUCTION" and appears to be an amendment to a previous plan, suggesting this is a revised electrical design document for a specific building or renovation project.
View the file
Other files
Show all 14
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Microwave
GFCI
A. FOLLOW MOUNTING HEIGHTS INDICATED IN THE ELECTRICAL LEGEND UNLESS
OTHERWISE INDICATED. MEASURE ALL MOUNTING HEIGHTS FROM THE DEVICE
CENTER LINE UNLESS OTHERWISE INDICATED.
B. FIELD VERIFY EXACT FEEDER LOCATIONS FOR MECHANICAL EQUIPMENT PRIOR
TO ROUGH-IN.
C. EQUIPMENT CONNECTIONS ARE INDICATED IN THEIR APPROXIMATE LOCATIONS.
VERIFY EXACT LOCATIONS OF ALL CONNECTIONS WITH OTHER TRADES
SUPPLYING EQUIPMENT TO AVOID CONFLICTS AT INSTALLATION.
D. LOCATED ALL SWITCHES FOR LOCAL CONTROL OF LIGHTING ON STRIKE SIDE OF
SINGLE DOORS UNLESS OTHERWISE INDICATED.
E. PROVIDE SPECIFIC BREAKER ARRANGEMENT FOR THE PANEL BOARDS
WHEREVER PHYSICALLY POSSIBLE. PROVIDE AS-BUILT DRAWINGS INDICATING
ACTUAL BRANCH CIRCUIT ARRANGEMENT. PROVIDE TYPE WRITTEN PANELBOARD
DIRECTORIES INDICATING ACTUAL BRANCH CIRCUIT ARRANGEMENT.
F. PROVIDE AS-BUILT DRAWINGS INDICATING ACTUAL BRANCH CIRCUIT
ARRANGEMENT. PROVIDE TYPEWRITTEN PANELBOARD DIRECTORIES INDICATING
ACTUAL BRANCH CIRCUIT ARRANGEMENT. HAND WRITTEN SCHEDULES ARE NOT
ACCEPTABLE.
G. ALL CONDUIT RUNS INDICATED ARE DIAGRAMMATIC, COORDINATE ROUTING IN
ALL SPACES WITH OTHER TRADES.
H. ALL PANELBOARDS INDICATED ARE HOUSED IN A SINGLE WIDTH ENCLOSURE,
UNO. THE CONTRACTOR SHALL FIELD VERIFY ROOM LAYOUT AND ADJUST
ACCORDINGLY, AT NO COST TO THE OWNER, IF PROVIDING ANY PANELBOARD
ENCLOSURES.
I. WHERE POWER AND COMMUNICATION OUTLETS ARE INDICATED IN CLOSE
PROXIMITY ON THE DRAWINGS, FIELD COORDINATE THE LOCATIONS TO PLACE
THE OUTLETS ADJACENT TO EACH OTHER.
J. ALL EXTERIOR RECEPTACLES SHALL BE LABELED "WR" - WEATHER RESISTANT.
K. WHEN GROUPING MULTIPLE LINE TO NEUTRAL BRANCH CIRCUITS IN A CONDUIT,
PROVIDE DEDICATED COLOR CODED NEUTRAL CONDUCTORS FOR EACH CIRCUIT.
DO NOT USE BREAKER TIES AND SHARED NEUTRALS EVEN THOUGH PERMITTED
BY NEC.
L. PROVIDE A 2” WIDE YELLOW LINE PAINTED ON THE FLOOR INDICATING THE
ELECTRICAL WORKING SPACE. IN FRONT OF ALL ELECTRICAL PANELS IN
ELECTRICAL ROOMS. REFER TO PLANS FOR ELECTRICAL WORKING SPACE
DETAILS. STENCIL “NO STORAGE” IN 2” HIGH, YELLOW LETTERS CENTERED IN THE
OUTLINED AREA.
GENERAL NOTES:
Date:
BLM Job #:
U ni te d
St at es D ep ar tm en t o f t he In te rio r Bu re au o f L an d
M an ag em en t
Checked by:
R ev is io ns
D es cr ip tio n
D at e
NOT FOR CONSTRUCTION
D es cr ip tio n
D at e
0%
C O
N
ST
R U
C
TI
O N
D O
C U
M
EN
TS
AM
EN
D
M
EN
T
/0
5/
9/ 5/
:0
8:
P M
E-101
POWER PLAN
C
AN
M
LA
KE
VI
EW
IN
TE
R N
H O
U
SI
N G
CANM -
LAKEVIEW
INTERN
HOUSING
JANUARY 17, 2025
C
AN
YO
N
S O
F
TH
E
AN
C
IE
N
TS
N
AT
IO
N
AL
M
O N
U M
EN
T
NOC AE
1/4" = 1'-0"
POWER PLAN1
REFEED EXISTING PANEL FROM NEW
EXTERIOR PANEL
Electrical Fixture Schedule Description Count
240V RECEPTACLE - 18" AFF 1
DUPLEX RECEPTACLE - 18" AFF 7
GFCI DUPLEX RECEPTACLE - 18"AFF 8
GFCI DUPLEX RECEPTACLE - 46" AFF 1
QUAD RECEPTACLE - 46" AFF 2
WR GFCI DUPLEX RECEPTACLE 3R ENCLOSURE - 18" AFF 4
0 40 6020
GRAPHIC SCALE
NEW NEMA 3R, 200A EXTERIOR
INSTALL OUTLET IN CAB.
ABOVE MICROWAVE
AMENDMENT
| Sheets |
| E-001 - PNL SCHEDULE, ONE-LINE, LEGENDS, AND GEN NOTES |
| E-101 - POWER PLAN |
File details come from the government source that posted it. Updated .