E-101_-_Updated_09-05-25_0002.pdf

PDF 174 KB Posted

Attached to
BLM-CO TRFO CANM LAKEVIEW INTERN HOUSING
Solicitation number
140L1725R0003
Issued by

About this file

This document is an electrical power plan schematic for a building, specifically drawing E-101, dated 9/5/2025. The plan details a comprehensive electrical upgrade involving the installation of a new NEMA 3R, 200A exterior panel and refeed of an existing panel. Key electrical modifications include installing a GFCI outlet in a cabinet above a microwave, with the drawing providing a detailed floor plan layout showing outlet and panel locations.

The document includes a general notes section with technical specifications for electrical installations, such as routing guidelines, panel enclosure requirements, and wiring instructions. An electrical fixture schedule is also present, indicating specific electrical components and their quantities. The drawing is marked "NOT FOR CONSTRUCTION" and appears to be an amendment to a previous plan, suggesting this is a revised electrical design document for a specific building or renovation project.

View the file

Other files

Show all 14

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Microwave

GFCI

A. FOLLOW MOUNTING HEIGHTS INDICATED IN THE ELECTRICAL LEGEND UNLESS

OTHERWISE INDICATED. MEASURE ALL MOUNTING HEIGHTS FROM THE DEVICE

CENTER LINE UNLESS OTHERWISE INDICATED.

B. FIELD VERIFY EXACT FEEDER LOCATIONS FOR MECHANICAL EQUIPMENT PRIOR

TO ROUGH-IN.

C. EQUIPMENT CONNECTIONS ARE INDICATED IN THEIR APPROXIMATE LOCATIONS.

VERIFY EXACT LOCATIONS OF ALL CONNECTIONS WITH OTHER TRADES

SUPPLYING EQUIPMENT TO AVOID CONFLICTS AT INSTALLATION.

D. LOCATED ALL SWITCHES FOR LOCAL CONTROL OF LIGHTING ON STRIKE SIDE OF

SINGLE DOORS UNLESS OTHERWISE INDICATED.

E. PROVIDE SPECIFIC BREAKER ARRANGEMENT FOR THE PANEL BOARDS

WHEREVER PHYSICALLY POSSIBLE. PROVIDE AS-BUILT DRAWINGS INDICATING

ACTUAL BRANCH CIRCUIT ARRANGEMENT. PROVIDE TYPE WRITTEN PANELBOARD

DIRECTORIES INDICATING ACTUAL BRANCH CIRCUIT ARRANGEMENT.

F. PROVIDE AS-BUILT DRAWINGS INDICATING ACTUAL BRANCH CIRCUIT

ARRANGEMENT. PROVIDE TYPEWRITTEN PANELBOARD DIRECTORIES INDICATING

ACTUAL BRANCH CIRCUIT ARRANGEMENT. HAND WRITTEN SCHEDULES ARE NOT

ACCEPTABLE.

G. ALL CONDUIT RUNS INDICATED ARE DIAGRAMMATIC, COORDINATE ROUTING IN

ALL SPACES WITH OTHER TRADES.

H. ALL PANELBOARDS INDICATED ARE HOUSED IN A SINGLE WIDTH ENCLOSURE,

UNO. THE CONTRACTOR SHALL FIELD VERIFY ROOM LAYOUT AND ADJUST

ACCORDINGLY, AT NO COST TO THE OWNER, IF PROVIDING ANY PANELBOARD

ENCLOSURES.

I. WHERE POWER AND COMMUNICATION OUTLETS ARE INDICATED IN CLOSE

PROXIMITY ON THE DRAWINGS, FIELD COORDINATE THE LOCATIONS TO PLACE

THE OUTLETS ADJACENT TO EACH OTHER.

J. ALL EXTERIOR RECEPTACLES SHALL BE LABELED "WR" - WEATHER RESISTANT.

K. WHEN GROUPING MULTIPLE LINE TO NEUTRAL BRANCH CIRCUITS IN A CONDUIT,

PROVIDE DEDICATED COLOR CODED NEUTRAL CONDUCTORS FOR EACH CIRCUIT.

DO NOT USE BREAKER TIES AND SHARED NEUTRALS EVEN THOUGH PERMITTED

BY NEC.

L. PROVIDE A 2” WIDE YELLOW LINE PAINTED ON THE FLOOR INDICATING THE

ELECTRICAL WORKING SPACE. IN FRONT OF ALL ELECTRICAL PANELS IN

ELECTRICAL ROOMS. REFER TO PLANS FOR ELECTRICAL WORKING SPACE

DETAILS. STENCIL “NO STORAGE” IN 2” HIGH, YELLOW LETTERS CENTERED IN THE

OUTLINED AREA.

GENERAL NOTES:

Date:

BLM Job #:

U ni te d

St at es D ep ar tm en t o f t he In te rio r Bu re au o f L an d

M an ag em en t

Checked by:

R ev is io ns

D es cr ip tio n

D at e

NOT FOR CONSTRUCTION

D es cr ip tio n

D at e

0%

C O

N

ST

R U

C

TI

O N

D O

C U

M

EN

TS

AM

EN

D

M

EN

T

/0

5/

9/ 5/

:0

8:

P M

E-101

POWER PLAN

C

AN

M

LA

KE

VI

EW

IN

TE

R N

H O

U

SI

N G

CANM -

LAKEVIEW

INTERN

HOUSING

JANUARY 17, 2025

C

AN

YO

N

S O

F

TH

E

AN

C

IE

N

TS

N

AT

IO

N

AL

M

O N

U M

EN

T

NOC AE

1/4" = 1'-0"

POWER PLAN1

REFEED EXISTING PANEL FROM NEW

EXTERIOR PANEL

Electrical Fixture Schedule Description Count

240V RECEPTACLE - 18" AFF 1

DUPLEX RECEPTACLE - 18" AFF 7

GFCI DUPLEX RECEPTACLE - 18"AFF 8

GFCI DUPLEX RECEPTACLE - 46" AFF 1

QUAD RECEPTACLE - 46" AFF 2

WR GFCI DUPLEX RECEPTACLE 3R ENCLOSURE - 18" AFF 4

0 40 6020

GRAPHIC SCALE

NEW NEMA 3R, 200A EXTERIOR

INSTALL OUTLET IN CAB.

ABOVE MICROWAVE

AMENDMENT

Sheets
E-001 - PNL SCHEDULE, ONE-LINE, LEGENDS, AND GEN NOTES
E-101 - POWER PLAN

File details come from the government source that posted it. Updated .