This document is a performance specification for the electrical systems of the Cedar City Air Base Improvements project. It describes the requirements for the exterior electrical distribution, site lighting, communications, and security systems. Key details include:

The Design Build Contractor (DBC) is responsible for determining the electrical system requirements and obtaining necessary permits. The electrical systems must comply with BLM Codes and Standards as well as industry standards for security lighting, electrical distribution, and telecommunications. Requirements are provided for voltage drop, grounding, wiring, overcurrent protection, and receptacle layout. The DBC must submit design calculations, drawings, and construction submittals for review and approval. Specified components include underground conduits, pullboxes, lighting fixtures, panelboards, surge protection, and a photovoltaic system. The document also includes requirements for the site communications and security systems to be coordinated with the project.

View the file

Other files

Show all 17

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

For the best experience, open this PDF portfolio in

Acrobat X or Adobe Reader X, or later.

Get Adobe Reader Now!

http://www.adobe.com/go/reader

Cedar City Air Base Improvements Color Country District Cedar City, UT

SECTION C40

DOORS AND HARDWARE PAGE 1

DOORS AND HARDWARE

GENERAL

1 .1 SUMMARY

A. This section consists of Exterior and Interior Doors and Hardware:

1. Hollow Metal Doors and Frames

2. Flush Wood Doors.

3. Commercial door hardware and electrified door hardware as shown or specified for both exterior and interior doors.

1 .2 REFERENCES

A. Use date of standard or code in effect.

B. State and Local Codes including Authority Having Jurisdiction.

C. ANSI/BHMA A156 – Builders Hardware Manufacturers Association Builders Hardware Standards.

D. NFPA – National Fire Protection Association:

1. NFPA 80 – Fire Doors and Windows.

2. NFPA 105 – Smoke and Draft Control Door Assemblies.

3. NFPA 252 - Standard Methods of Fire Tests of Door Assemblies.

4. NFPA 101 – Life Safety Code.

E. UL – Underwriters Laboratories:

1. UL10C – Fire Tests of Door Assemblies (Positive Pressure).

2. UL 1784 - Air Leakage Tests of Door Assemblies.

F. ANSI A117.1 – Accessible and Usable Buildings and Facilities.

G. ADA – Americans with Disabilities Act.

H. DHI – Door and Hardware Institute.

I. SDI – Steel Door Institute.

DOORS AND HARDWARE PAGE 2

J. WDMA – Window and Door Manufacturers Association.

1 .3 GENERAL REQUIREMENTS

A. Requirements of Regulatory Agencies:

1. Furnish finish hardware to comply with the requirements of laws, codes, ordinances, and regulations of the governmental authorities having jurisdiction where such requirements exceed the requirements of the Specifications. Furnish finish hardware to comply with the requirements of the American National Standards for Making Buildings and Facilities Accessible to and Usable by Physically Handicapped People (ICC/ANSI A117.1) and to comply with Americans with Disabilities Act (ADA).

B. Source Limitations: Obtain each type and variety of door hardware from a single manufacturer, unless otherwise indicated.

C. Provide electrified door hardware from same manufacturer as mechanical door hardware, unless otherwise indicated. Manufacturers that perform electrical modifications and that are listed by a testing and inspecting agency acceptable to authorities having jurisdiction are acceptable.

D. Coordination

1. Coordinate work of this Section with other directly affected Sections involving manufacture of any internal reinforcement for door hardware. Furnish hardware templates to door fabricators for factory preparation to receive hardware.

2. Furnish hardware items of proper design for use on doors and frames of thicknesses, profile, swing, security, and other indicated requirements as necessary for proper function.

3. Coordinate solid blocking between studs of frame construction to support wall mounted items such as stops.

4. Electrical System Roughing-in: Coordinate layout and installation of electrified door hardware with connections to power supplies, fire alarm system and detection devices and access control system.

5. Hardware and keying conference with Owner prior to final approval of doors and hardware.

6. Use hardware consultant to check Shop Drawings for doors and entrances to confirm that adequate provisions will be made for proper hardware installation.

1 .4 WARRANTY

A. Doors

1. General Warranty: Special warranties specified in this Article shall not deprive Owner of other rights Owner may have under other provisions of the Contract Documents and shall be in addition to, and run concurrent with, other warranties made by Contractor under requirements of the Contract Documents.

DOORS AND HARDWARE PAGE 3

2. Special Warranty: Written warranty, executed by manufacturer agreeing to repair or replace components of door hardware that fail in materials or workmanship within specified warranty period. Failures include, but are not limited to, the following:

a. Structural failures including excessive deflection, cracking, or breakage.

b. Faulty operation of operators and door hardware.

c. Deterioration of metals, metal finishes, and other materials beyond normal weathering.

3. Warranty Period: 2 years from date of Substantial Completion, unless otherwise indicated.

a. Warranty Period for Manual Closers: 10 years from date of Completion.

b. Warranty Period for Exit Devices: 3 years from date of Completion.

c. Warranty period for Locksets: 5 years, blanket coverage, from date of

B. Sectional Doors:

1. Special Warranty: Manufacturer agrees to repair or replace components of sectional doors that fail in materials or workmanship within specified warranty period.

2. Warranty Period: Ten years from date of Substantial Completion.

3. Special Finish Warranty: Manufacturer agrees to repair or replace components that show evidence of deterioration of factory-applied finishes within specified warranty period.

4. Warranty Period: Ten years from date of Substantial Completion.

5. Maintenance Tools and Instructions: Furnish a complete set of specialized tools and maintenance instructions as needed for Owner's continued adjustment, maintenance, and removal and replacement of door hardware.

1 .5 THERMAL PERFORMANCE

A. Exterior Doors shall comply with Energy Star requirements based on glazing level for the zone the project is located as listed below:

1. Opaque doors (no glass) must have a U-factor of 0.17 or less (no SHGC requirement).

2. 1/4- or 1/2-Lite doors (about 50% glass or less) must have a U-factor of 0.25 or less and an SHGC of 0.25 or less.

3. 3/4- or Full-Lite doors (more than 50% glass) must have a U-factor of 0.30 or less and an SHGC of 0.40 or less.

4. U Value determined in accordance with NFRC 100 and SHGC in accordance with NRFC 200.

DOORS AND HARDWARE PAGE 4

5. All exterior doors to be metal with metal frames.

B. Interior Doors.

1. Solid core wood door 3’-0” x 6’-8”

2. Steel Frame

3. Lever type handle on offices and conference/training rooms

4. Keypad on high security doors.

5. Interior Offices to have an 18” wide full-length sidelight window adjacent to the door.

1 .6 QUALITY ASSURANCE

A. Door Hardware Supplier Qualifications: Experienced commercial door hardware distributors with a minimum 5 years documented experience supplying both mechanical and electromechanical hardware installations comparable in material, design, and extent to that indicated for this Project.

Supplier recognized as a factory direct distributor by the manufacturers of the primary materials with a warehousing facility in Project's vicinity. Supplier to have on staff a certified Architectural Hardware Consultant (AHC) available during the course of the Work to consult with Contractor, Architect, and Owner concerning both standard and electromechanical door hardware and keying.

B. Keying Conference: Conduct conference with Owner to incorporate the following criteria into the final keying schedule document:

1. Function of building, purpose of each area and degree of security required.

2. Plans for existing and future key system expansion.

3. Requirements for key control storage and software.

4. Installation of permanent keys, cylinder cores and software.

5. Address location and requirements for delivery of keys.

C. Commissioning:

1. The General Contractor in conjunction with the lock manufacturer’s representative, hardware installer and supplying distributor shall commission hardware.

a. Test door hardware operation with climate control system both at rest and while in full operation.

b. Test electrical and electronic hardware systems for satisfactory operation.

c. Test hardware interfaced with fire/life-safety system for proper operation and release.

DOORS AND HARDWARE PAGE 5

1 .7 COMPLIANCE VERIFICATION

A. Specifications, design calculations and drawings shall be submitted during the design process as specified below and as specified in the Design Build SOW paragraphs “Schedule and Milestones”, “DBC Submission Requirements”, and “Design Requirements”. Compliance with the various codes and design criteria will be determined by a review of the design calculations, specifications, design drawings, construction submittals submitted during construction, and by field inspection.

Compliance review is to verify that the DBC is providing systems, products, and/or materials that will satisfy the stated criteria. This review shall not relieve the DBC from responsibility for any errors or omissions nor from responsibility for complying with the requirements of this contract.

1 .8 SUBMITTALS DURING CONSTRUCTION

A. Submit the following for review and approval in accordance with the Design Build SOW Paragraph “Submittals During Construction”.

B. Manufacturer’s Catalog Data:

1. Door hardware, with schedule:

a. Door Hardware Schedule: Prepared by or under the supervision of supplier, detailing fabrication and assembly of door hardware, as well as procedures and diagrams.

Coordinate the final Door Hardware Schedule with doors, frames, and related work to ensure proper size, thickness, hand, function, and finish of door hardware.

b. Details of electrified access control hardware indicating the following:

1) Wiring Diagrams: Upon receipt of approved schedules, submit detailed system wiring diagrams for power, signaling, monitoring, communication, and control of the access control system electrified hardware. Differentiate between manufacturer-installed and field-installed wiring. Include the following:

a) Elevation diagram of each unique access controlled opening showing location and interconnection of major system components with respect to their placement in the respective door openings.

b) Complete (risers, point-to-point) access control system block wiring diagrams.

c) Wiring instructions for each electronic component scheduled herein.

2) Electrical Coordination: Coordinate with related sections the voltages and wiring details required at electrically controlled and operated hardware openings.

c. Keying Schedule: After a keying meeting with the owner has taken place prepare a separate keying schedule detailing final instructions. Submit the keying schedule in electronic format. Include keying system explanation, door numbers, key set

DOORS AND HARDWARE PAGE 6

symbols, hardware set numbers and special instructions. Owner must approve submitted keying schedule prior to the ordering of permanent cylinders/cores.

d. Source Limitations: Obtain each type and variety of door hardware specified in this section from a single source unless otherwise indicated.

1) Electrified modifications or enhancements made to a source manufacturer's product line by a secondary or third-party source will not be accepted.

2) Provide electromechanical door hardware from the same manufacturer as mechanical door hardware, unless otherwise indicated.

2. Lock box

C. Operation and Maintenance Data:

1. Doors.

2. Hardware.

D. Samples:

1. Paint color samples

PART 2 SYSTEM COMPONENTS

2 .1 GENERAL

A. Performance Requirements

1. Fire-Rated Door Assemblies: Assemblies complying with NFPA 80 that are listed and labeled by a qualified testing agency acceptable to authorities having jurisdiction for fire-protection ratings and temperature-rise limits indicated on Drawings, based on testing at positive pressure according to NFPA 252 or UL 10C.

a. Smoke- and Draft-Control Door Assemblies: Listed and labeled for smoke and draft control by a qualified testing agency acceptable to authorities having jurisdiction, based on testing according to UL 1784 and installed in compliance with NFPA 105.

b. Temperature-Rise Limit: At vertical exit enclosures and exit passageways, provide doors that have a maximum transmitted temperature end point of not more than 450 deg F above ambient after 30 minutes of standard fire-test exposure.

2. Fire-Rated, Borrowed-Lite Assemblies: Complying with NFPA 80 and listed and labeled by a qualified testing agency acceptable to authorities having jurisdiction, for fire-protection ratings indicated, based on testing according to NFPA 257 or UL 9.

B. Clearances

DOORS AND HARDWARE PAGE 7

1. Edge clearances between doors and frames: 1/8 inch.

2. At door sills with no threshold: 1/2 inch standard unless noted otherwise.

3. At door sills with threshold: 1/4 inch maximum between door and threshold.

4. At door sills at carpet: 1/4 inch higher than the thickness of the carpet.

5. Between meeting edges of pairs of doors: 1/8 inch

C. Identifying devices/signage:

1. Install signage in accordance with ADA and manufacturer's instructions.

2. Entry Glass Doors: Install vinyl die cut and reverse vinyl die cut letter signs on glazing on doors centered on doors at 54” above finished floor.

2 .2 GLAZING

A. Exterior Doors: 5/8" total, 1/4" laminated at exterior, 1/8" air space, 1/4" Low E laminated at interior.

B. Interior Doors: Laminated Glass of equal thicknesses (1/8" minimum) inner and outer faces of heat strengthened float glass laminated in autoclave under heat and pressure to a clear polyvinyl butyl sheet. Fabricate to produce glass free of foreign substances and air or glass pockets.

C. Seal: Dual-seal consisting of butyl primary seal and silicone secondary seal required. Provide spacers filled with desiccant and bent or soldered corners to provide a sealed edge.

D. Provide flush integral stops on one side and flush screw on stops on the opposite side. This includes windows in doors. Provide removable stop at building interior of exterior windows and room side away from corridors at interior windows. Provide stops, shaped as required and hand fitted with butt joints that are square and true and tightly fitted. Gaps at stops will not be permitted.

1. Stiles and rails: Wide stile (5" nominal width). Construct the doors using 5" wide stiles, 7” top rail, and a solid 10" bottom rail.

2. Fasten to frame with metal screws at 18" o.c. maximum, flathead, countersunk. Do not over-tighten to cause indentations or puckering. Provide vandal proof screws at exterior stops when the drawings specifically require removable stops at the exterior.

2 .3 HOLLOW METAL DOORS AND FRAMES

A. General: Construct hollow-metal doors and frames to comply with standards indicated for materials, fabrication, hardware locations, hardware reinforcement, tolerances, and clearances, and as specified.:

B. Standard Steel Doors and Frames

DOORS AND HARDWARE PAGE 8

1. Doors

a. Type: As indicated in the Door and Frame Schedule.

b. Thickness: 1-3/4 inches.

c. Face:

1) Exterior: Metallic-coated steel sheet, minimum 16 gauge (0.053”), with minimum G90 coating.

2) Interior: Metallic-coated steel sheet, minimum 16 gauge (0.053”).

d. Edge Construction: Model 2, Seamless.

e. Top Edge Closures: Close top edges of doors with flush closures of same material as face sheets. Seal joints against water penetration.

f. Bottom Edges: Close bottom edges of doors where required for attachment of weather stripping with end closures or channels of same material as face sheets.

Provide weep-hole openings in bottoms of exterior doors to permit moisture to escape.

g. Core: Polystyrene and Vertical steel stiffener.

h. Fire-Rated Core: Manufacturer's standard vertical steel stiffener with insulation core for fire rated doors.

2. Frames

a. Materials:

1) Exterior: Metallic-coated steel sheet, minimum 14 gage (0.067”), with minimum G90 coating.

2) Interior: Metallic-coated steel sheet, minimum 16 gage (0.053”).

b. Construction: Fully welded and ground smooth.

c. Head reinforced for closer.

d. Exterior: Fill door jambs solid with rock wool.

3. Frame Anchors

a. Jamb Anchors:

1) Type: Anchors of minimum size and type required by applicable door and frame standard, and suitable for performance level indicated.

DOORS AND HARDWARE PAGE 9

2) Quantity: Minimum of three anchors per jamb, with one additional anchor for frames with no floor anchor. Provide one additional anchor for each 24 inches of frame height above 7 feet.

3) Post-installed Expansion Anchor: Minimum 3/8-inch-diameter bolts with expansion shields or inserts, with manufacturer's standard pipe spacer

4) Floor Anchors: Provide floor anchors for each jamb and mullion that extends to floor.

b. Floor Anchors for Concrete Slabs with Underlayment: Adjustable-type anchors with extension clips, allowing not less than 2-inch height adjustment. Terminate bottom of frames at top of underlayment.

c. Material: ASTM A879/A879M, Commercial Steel (CS), 04Z coating designation;

mill phosphatized.

1) For anchors built into exterior walls, steel sheet complying with ASTM A1008/A1008M or ASTM A1011/A1011M; hot-dip galvanized according to ASTM A153/A153M, Class B.

2 .4 FLUSH WOOD INTERIOR DOORS

A. General:

1. Quality Standard: In addition to requirements specified, comply with Architectural Woodwork Standards.

a. Provide labels and certificates from AWI certification program indicating that doors comply with requirements of grades specified.

2. Adhesives: Use adhesives that meet the testing and product requirements of the California Department of Public Health's "Standard Method for the Testing and Evaluation of Volatile Organic Chemical Emissions from Indoor Sources Using Environmental Chambers."

3. Composite Wood Products: Products shall be made using ultra-low-emitting formaldehyde resins as defined in the California Air Resources Board's "Airborne Toxic Control Measure to Reduce Formaldehyde Emissions from Composite Wood Products" or shall be made with no added formaldehyde.

B. Construction: Five-ply flush wood veneer-faced doors for transparent finish

1. Doors:

a. Type: As indicated in the Door and Frame Schedule.

b. Thickness: 1-3/4 inches.

c. Manufacturers: Basis of Design: VT Industries Inc. Heritage Collection Five Ply Flush Wood Veneer Door. Subject to compliance with requirements, available

DOORS AND HARDWARE PAGE 10

manufacturers offering products that may be incorporated into the Work include, but are not limited to, the following:

1) Algoma Hardwoods, Inc.

2) Eggers Industries.

3) Graham Wood Doors: ASSA ABLOY Group Company.

4) Marshfield Door Systems, Inc.

d. Performance Grade: WDMA I.S. 1A Heavy Duty.

e. Performance Grade:

1) WDMA I.S. 1A Heavy Duty unless otherwise indicated on Drawings.

f. Architectural Woodwork Standards Grade: Premium, Grade A.

g. Faces: Single-ply wood veneer not less than 1/50 inch thick.

1) Species: Select White Maple

2) Cut: Plain sliced (flat sliced).

3) Match between Veneer Leaves: Book match.

4) Assembly of Veneer Leaves on Door Faces: Balance match.

5) Room Match: Match door faces within each separate room or area of building.

Corridor-door faces do not need to match where they are separated by 10 feet or more.

6) Finish: Oasis OA18

h. Exposed Vertical and Top Edges: Same species as faces or a compatible species – Architectural Woodwork Standards edge Type A.

i. Core for Non-Fire-Rated Doors: ANSI A208.1, Grade LD-1 particleboard.

1) Blocking: Provide wood blocking in particleboard-core doors as follows:

a) 5-inch top-rail blocking, in doors indicated to have closers.

b) 5-inch bottom-rail blocking, in exterior doors and doors indicated to have kick, mop, or armor plates.

c) 5-inch midrail blocking, in doors indicated to have exit devices.

DOORS AND HARDWARE PAGE 11

j. Construction: Five plies, hot-pressed bonded (vertical and horizontal edging is bonded to core), with entire unit abrasive planed before veneering.

2. Light Openings in Wood Doors: Provide manufacturer's standard wood beads unless otherwise indicated.

a. Wood Species: Same species as door faces.

b. Profile: Manufacturer's standard shape.

3. Factory Finishing

a. Comply with referenced quality standard for factory finishing.

1) Complete fabrication, including fitting doors for openings and machining for hardware that is not surface applied, before finishing.

2) Finish faces, all four edges, edges of cutouts, and mortises.

b. Factory finish doors unless indicated otherwise.

c. Transparent Finish:

1) Architectural Woodwork Standards Grade: Premium.

2) Finish: WDMA I.S. 1A TR-6 Catalyzed Polyurethane.

3) Staining: Match Architect's sample

4) Sheen: Satin.

2 .5 FIRE DEPARTMENT LOCK BOX

A. Provide Knox Model No. 3200 Knox Vault (recessed or surface mount as required by Owner) or other lock box as required by local fire department, in quantity and location as directed by the fire department and approved. Recessed mount shall be furnished with recessed mounting kit (RMK) for new concrete or masonry construction.

2 .6 HARDWARE

A. General: Provide door hardware for each door to comply with requirements in Door Hardware Sets and each referenced section that products are to be supplied under

B. Provide Key numbering and Key Control Systems for each building type.

C. Hinges: ANSI/BHMA A156.1 certified butt hinges with number of hinge knuckles and other options as specified in the Door Hardware Sets.

1. Quantity: Provide the following hinge quantity:

DOORS AND HARDWARE PAGE 12

a. Two Hinges: For doors with heights up to 60 inches.

b. Three Hinges: For doors with heights 61 to 90 inches.

c. Four Hinges: For doors with heights 91 to 120 inches.

d. For doors with heights more than 120 inches, provide 4 hinges, plus 1 hinge for every 30 inches of door height greater than 120 inches.

2. Hinge Size: Provide the following, unless otherwise indicated, with hinge widths sized for door thickness and clearances required:

a. Widths up to 3’0”: 4-1/2” standard or heavy weight as specified.

3. Hinge Weight and Base Material: Unless otherwise indicated, provide the following:

a. Exterior Doors: Heavy weight, non-ferrous, ball bearing or oil impregnated bearing hinges unless Hardware Sets indicate standard weight.

b. Interior Doors: Standard weight, steel, ball bearing or oil impregnated bearing hinges unless Hardware Sets indicate heavy weight.

4. Hinge Options: Comply with the following:

a. Non-removable Pins: Provide set screw in hinge barrel that, when tightened into a groove in hinge pin, prevents removal of pin while door is closed; for all out-swinging lockable doors.

5. Manufacturers:

a. Hager Companies (HA).

b. McKinney Products; ASSA ABLOY Architectural Door Accessories (MK).

D. Door Push Plates and Pulls: ANSI/BHMA A156.6 certified door pushes and pulls of type and design specified in the Hardware Sets. Coordinate and provide proper width and height as required where conflicting hardware dictates.

1. Push/Pull Plates: Minimum .050 inch thick, size as indicated in hardware sets, with beveled edges, secured with exposed screws unless otherwise indicated.

2. Door Pull and Push Bar Design: Size, shape, and material as indicated in the hardware sets.

Minimum clearance of 2 1/2-inches from face of door unless otherwise indicated.

3. Offset Pull Design: Size, shape, and material as indicated in the hardware sets. Minimum clearance of 2 1/2-inches from face of door and offset of 90 degrees unless otherwise indicated.

4. Fasteners: Provide manufacturer's designated fastener type as indicated in Hardware Sets.

DOORS AND HARDWARE PAGE 13

5. Manufacturers:

a. Rockwood Products; ASSA ABLOY Architectural Door Accessories (RO).

E. Lock Cylinders

1. Lock Source Limitations: Obtain each type of keyed cylinder and keys from the same source manufacturer as locksets and exit devices, unless otherwise indicated.

a. Manufacturers:

1) Schlage (SC). (confirm keyway with owner prior to ordering).

2. Cylinders: Original manufacturer cylinders complying with the following:

a. Mortise Type: Threaded cylinders with rings and cams to suit hardware application.

b. Rim Type: Cylinders with back plate, flat-type vertical or horizontal tailpiece, and raised trim ring.

c. Bored-Lock Type: Cylinders with tailpieces to suit locks.

d. Mortise and rim cylinder collars to be solid and recessed to allow the cylinder face to be flush and be free spinning with matching finishes.

e. Keyway: Match Facility Standard.

F. Keys-Provide for each building type.

1. Keying System: Each type of lock and cylinders to be factory keyed.

a. Conduct specified "Keying Conference" to define and document keying system instructions and requirements.

b. Furnish factory cut, nickel-silver large bow permanently inscribed with a visual key control number as directed by Owner and include the following notation:

1) Notation: "DO NOT DUPLICATE “.

c. Existing System: Key locks to Owner's existing system.

2. Key Quantity: Provide the following minimum number of keys:

a. Change Keys per Cylinder: Two (2)

b. Master Keys (per Master Key Level/Group): Five (5).

c. Construction Keys (where required): Ten (10).

3. Construction Keying: Provide construction master keyed cylinders.

DOORS AND HARDWARE PAGE 14

4. Key Control Cabinet: Provide a key control system including envelopes, labels, and tags with self-locking key clips, receipt forms, 3-way visible card index, temporary markers, permanent markers, and standard metal cabinet. Key control cabinet shall have expansion capacity of 150% of the number of locks required for the project.

a. Wall-Mounted Cabinet: Grade 1 cabinet with hinged-panel door equipped with keyholding panels and pin-tumbler cylinder door lock.

b. Manufacturers:

1) Lund Equipment (LU).

2) Telkee (TK)

G. Mechanical Locks and Latching Devices

1. Cylindrical Locksets, Grade 1 (Heavy Duty): ANSI/BHMA A156.2, Series 4000, Grade 1 certified.

a. Furnish with solid cast levers, standard 2 3/4” backset, and 1/2" (3/4" at rated paired openings) throw brass or stainless steel latchbolt.

b. Locks are to be non-handed and fully field reversible.

c. Extended cycle test: Locks to have been cycle tested in ordinance with ANSI/BHMA

156.2 requirements to 2 million cycles.

d. Manufacturers:

1) Schlage (SC) – ND Series.

H. Lock and Latch Strikes

1. Strikes: Provide manufacturer's standard strike with strike box for each latch or lock bolt, with curved lip extended to protect frame, finished to match door hardware set, unless otherwise indicated, and as follows:

a. Flat-Lip Strikes: For locks with three-piece antifriction latch-bolts as recommended by manufacturer.

b. Extra-Long-Lip Strikes: For locks used on frames with applied wood casing trim.

c. Aluminum-Frame Strike Box: Provide manufacturer's special strike box fabricated for aluminum framing.

d. Double-lipped strikes: For locks at double acting doors. Furnish with retractable stop for rescue hardware applications.

2. Standards: Comply with the following:

DOORS AND HARDWARE PAGE 15

a. Strikes for Mortise Locks and Latches: BHMA A156.13.

b. Strikes for Bored Locks and Latches: BHMA A156.2.

c. Strikes for Auxiliary Deadlocks: BHMA A156.36.

d. Dustproof Strikes: BHMA A156.16.

I. Conventional Exit Devices

1. General Requirements: All exit devices specified herein shall meet or exceed the following criteria:

a. At doors not requiring a fire rating, provide devices complying with NFPA 101 and listed and labeled for "Panic Hardware" according to UL305. Provide proper fasteners as required by manufacturer including sex nuts and bolts at openings specified in the Hardware Sets.

b. Where exit devices are required on fire rated doors, provide devices complying with NFPA 80 and with UL labeling indicating "Fire Exit Hardware". Provide devices with the proper fasteners for installation as tested and listed by UL. Consult manufacturer’s catalog and template book for specific requirements.

c. Except on fire rated doors, provide exit devices with hex key dogging device to hold the pushbar and latch in a retracted position. Provide optional keyed cylinder dogging on devices where specified in Hardware Sets.

d. Devices must fit flat against the door face with no gap that permits unauthorized dogging of the push bar. The addition of filler strips is required in any case where the door light extends behind the device as in a full glass configuration.

e. Lever Operating Trim: Where exit devices require lever trim, furnish manufacturer's heavy duty escutcheon trim with threaded studs for thru-bolts.

1) Lock Trim Design: As indicated in Hardware Sets, provide finishes and designs to match that of the specified locksets.

2) Where function of exit device requires a cylinder, provide a cylinder (Rim or Mortise) as specified in Hardware Sets.

f. Vertical Rod Exit Devices: Where surface or concealed vertical rod exit devices are used at interior openings, provide as less bottom rod (LBR) unless otherwise indicated. Provide dust proof strikes where thermal pins are required to project into the floor.

g. Narrow Stile Applications: At doors constructed with narrow stiles, or as specified in Hardware Sets, provide devices designed for maximum 2” wide stiles.

h. Dummy Push Bar: Nonfunctioning push bar matching functional push bar.

DOORS AND HARDWARE PAGE 16

i. Rail Sizing: Provide exit device rails factory sized for proper door width application.

j. Through Bolt Installation: For exit devices and trim as indicated in Door Hardware Sets.

2. Conventional Push Rail Exit Devices (Heavy Duty): ANSI/BHMA A156.3, Grade 1 certified panic and fire exit hardware devices furnished in the functions specified in the Hardware Sets. Exit device latch to be stainless steel, pullman type, with deadlock feature.

1) Von Duprin (VD) - 35A/98 XP Series.

J. Door Closures

1. All door closers specified herein shall meet or exceed the following criteria:

a. General: Door closers to be from one manufacturer, matching in design and style, with same type door preparations and templates regardless of application or spring size. Closers to be non-handed with full sized covers including installation and adjusting information on inside of cover.

b. Standards: Closers to comply with UL-10C for Positive Pressure Fire Test and be U.L. listed for use of fire rated doors.

c. Cycle Testing: Provide closers which have surpassed 15 million cycles in a test witnessed and verified by UL.

d. Size of Units: Comply with manufacturer's written recommendations for sizing of door closers depending on size of door, exposure to weather, and anticipated frequency of use. Where closers are indicated for doors required to be accessible to the physically handicapped, provide units complying with ANSI ICC/A117.1.

e. Closer Arms: Provide heavy duty, forged steel closer arms unless otherwise indicated in Hardware Sets.

f. Closers shall not be installed on exterior or corridor side of doors; where possible install closers on door for optimum aesthetics.

g. Closer Accessories: Provide door closer accessories including custom templates, special mounting brackets, spacers and drop plates as required for proper installation.

Provide through-bolt and security type fasteners as specified in the hardware sets.

2. Door Closers, Surface Mounted (Large Body Cast Iron): ANSI/BHMA A156.4, Grade 1 surface mounted, heavy duty door closers with complete spring power adjustment, sizes 1 thru 6; and fully operational adjustable according to door size, frequency of use, and opening force. Closers to be rack and pinion type, one-piece cast iron body construction, with adjustable backcheck and separate non-critical valves for closing sweep and latch speed control.

DOORS AND HARDWARE PAGE 17

1) LCN Closers (LC) - 4040XP Series.

K. Architectural Trim

1. Door Protective Trim

a. General: Door protective trim units to be of type and design as specified below or in the Hardware Sets.

b. Size: Fabricate protection plates (kick, armor, or mop) not more than 2" less than door width (LDW) on stop side of single doors and 1” LDW on stop side of pairs of doors, and not more than 1" less than door width on pull side. Coordinate and provide proper width and height as required where conflicting hardware dictates.

Height to be as specified in the Hardware Sets.

c. Where plates are applied to fire rated doors with the top of the plate more than 16” above the bottom of the door, provide plates complying with NFPA 80. Consult manufacturer’s catalog and template book for specific requirements for size and applications.

d. Protection Plates: ANSI/BHMA A156.6 certified protection plates (kick, armor, or mop), fabricated from the following:

1) Stainless Steel: 300 grade, 050-inch thick.

e. Options and fasteners: Provide manufacturer's designated fastener type as specified in the Hardware Sets. Provide countersunk screw holes.

f. Manufacturers:

1) Rockwood Products; ASSA ABLOY Architectural Door Accessories (RO).

2) Trimco (TC).

L. Door Stops and Holders

1. General: Door stops and holders to be of type and design as specified below or in the Hardware Sets.

2. Door Stops and Bumpers: ANSI/BHMA A156.16, Grade 1 certified door stops and wall bumpers. Provide wall bumpers, either convex or concave types with anchorage as indicated, unless floor or other types of door stops are specified in Hardware Sets. Do not mount floor stops where they will impede traffic. Where floor or wall bumpers are not appropriate, provide overhead type stops and holders.

1) Rockwood Products; ASSA ABLOY Architectural Door Accessories (RO).

DOORS AND HARDWARE PAGE 18

2) Trimco (TC).

M. Architectural Seals

1. General: Thresholds, weatherstripping, and gasket seals to be of type and design as specified below or in the Hardware Sets. Provide continuous weatherstrip gasketing on exterior doors and provide smoke, light, or sound gasketing on interior doors where indicated. At exterior applications provide non-corrosive fasteners and elsewhere where indicated.

2. Smoke Labeled Gasketing: Assemblies complying with NFPA 105 that are listed and labeled by a testing and inspecting agency acceptable to authorities having jurisdiction, for smoke control ratings indicated, based on testing according to UL 1784.

a. Provide smoke labeled perimeter gasketing at all smoke labeled openings.

3. Fire Labeled Gasketing: Assemblies complying with NFPA 80 that are listed and labeled by a testing and inspecting agency acceptable to authorities having jurisdiction, for fire ratings indicated, based on testing according to UL-10C.

a. Provide intumescent seals as indicated to meet UL10C Standard for Positive Pressure Fire Tests of Door Assemblies, and NPFA 252, Standard Methods of Fire Tests of Door Assemblies.

4. Sound-Rated Gasketing: Assemblies that are listed and labeled by a testing and inspecting agency, for sound ratings indicated.

5. Replaceable Seal Strips: Provide only those units where resilient or flexible seal strips are easily replaceable and readily available from stocks maintained by manufacturer.

6. Manufacturers:

a. National Guard Products (NG).

b. Pemko Products; ASSA ABLOY Architectural Door Accessories (PE).

N. Electric Accessories

1. Power Supplies: Provide Nationally Recognized Testing Laboratory Listed 12VDC or 24VDC (field selectable) filtered and regulated power supplies. Include battery backup option with integral battery charging capability in addition to operating the DC load in event of line voltage failure. Provide the least number of units, at the appropriate amperage level, sufficient to exceed the required total draw for the specified electrified hardware and access control equipment.

1) Security Door Controls (SD) - 630 Series.

2) Securitron (SU) - BPS Series.

DOORS AND HARDWARE PAGE 19

3) Von Duprin (VD) - PS.

O. Finishes

1. Standard: Designations used in the Hardware Sets and elsewhere indicate hardware finishes complying with ANSI/BHMA A156.18, including coordination with traditional U.S. finishes indicated by certain manufacturers for their products.

2. Provide quality of finish, including thickness of plating or coating (if any), composition, hardness, and other qualities complying with manufacturer's standards, but in no case less than specified by referenced standards for the applicable units of hardware.

3. Protect mechanical finishes on exposed surfaces from damage by applying a strippable, temporary protective covering before shipping.

P. Provide other finish hardware as necessary for door function and location.

Q. Paint: Factory-primed doors and frames shall be painted with two coats of exterior grade latex (100% acrylic) semi-gloss paint. Color shall be as selected by the Government.

End of Section

1 general

1 .1 SUMMARY

A. This section consists of Exterior and Interior Doors and Hardware:

1. Hollow Metal Doors and Frames

2. Flush Wood Doors.

3. Commercial door hardware and electrified door hardware as shown or specified for both exterior and interior doors.

1 .2 REFERENCES

A. Use date of standard or code in effect.

B. State and Local Codes including Authority Having Jurisdiction.

C. ANSI/BHMA A156 – Builders Hardware Manufacturers Association Builders Hardware Standards.

D. NFPA – National Fire Protection Association:

1. NFPA 80 – Fire Doors and Windows.

2. NFPA 105 – Smoke and Draft Control Door Assemblies.

3. NFPA 252 - Standard Methods of Fire Tests of Door Assemblies.

4. NFPA 101 – Life Safety Code.

E. UL – Underwriters Laboratories:

1. UL10C – Fire Tests of Door Assemblies (Positive Pressure).

2. UL 1784 - Air Leakage Tests of Door Assemblies.

F. ANSI A117.1 – Accessible and Usable Buildings and Facilities.

G. ADA – Americans with Disabilities Act.

H. DHI – Door and Hardware Institute.

I. SDI – Steel Door Institute.

J. WDMA – Window and Door Manufacturers Association.

1 .3 GENERAL REQUIREMENTS

A. Requirements of Regulatory Agencies:

1. Furnish finish hardware to comply with the requirements of laws, codes, ordinances, and regulations of the governmental authorities having jurisdiction where such requirements exceed the requirements of the Specifications. Furnish finish hardware t...

B. Source Limitations: Obtain each type and variety of door hardware from a single manufacturer, unless otherwise indicated.

C. Provide electrified door hardware from same manufacturer as mechanical door hardware, unless otherwise indicated. Manufacturers that perform electrical modifications and that are listed by a testing and inspecting agency acceptable to authorities h...

D. Coordination

1. Coordinate work of this Section with other directly affected Sections involving manufacture of any internal reinforcement for door hardware. Furnish hardware templates to door fabricators for factory preparation to receive hardware.

2. Furnish hardware items of proper design for use on doors and frames of thicknesses, profile, swing, security, and other indicated requirements as necessary for proper function.

3. Coordinate solid blocking between studs of frame construction to support wall mounted items such as stops.

4. Electrical System Roughing-in: Coordinate layout and installation of electrified door hardware with connections to power supplies, fire alarm system and detection devices and access control system.

5. Hardware and keying conference with Owner prior to final approval of doors and hardware.

6. Use hardware consultant to check Shop Drawings for doors and entrances to confirm that adequate provisions will be made for proper hardware installation.

1 .4 WARRANTY

A. Doors

1. General Warranty: Special warranties specified in this Article shall not deprive Owner of other rights Owner may have under other provisions of the Contract Documents and shall be in addition to, and run concurrent with, other warranties made by Co...

2. Special Warranty: Written warranty, executed by manufacturer agreeing to repair or replace components of door hardware that fail in materials or workmanship within specified warranty period. Failures include, but are not limited to, the following:

a. Structural failures including excessive deflection, cracking, or breakage.

b. Faulty operation of operators and door hardware.

c. Deterioration of metals, metal finishes, and other materials beyond normal weathering.

3. Warranty Period: 2 years from date of Substantial Completion, unless otherwise indicated.

a. Warranty Period for Manual Closers: 10 years from date of Completion.

b. Warranty Period for Exit Devices: 3 years from date of Completion.

c. Warranty period for Locksets: 5 years, blanket coverage, from date of

B. Sectional Doors:

1. Special Warranty: Manufacturer agrees to repair or replace components of sectional doors that fail in materials or workmanship within specified warranty period.

2. Warranty Period: Ten years from date of Substantial Completion.

3. Special Finish Warranty: Manufacturer agrees to repair or replace components that show evidence of deterioration of factory-applied finishes within specified warranty period.

4. Warranty Period: Ten years from date of Substantial Completion.

5. Maintenance Tools and Instructions: Furnish a complete set of specialized tools and maintenance instructions as needed for Owner's continued adjustment, maintenance, and removal and replacement of door hardware.

1 .5 THERMAL PERFORMANCE

A. Exterior Doors shall comply with Energy Star requirements based on glazing level for the zone the project is located as listed below:

1. Opaque doors (no glass) must have a U-factor of 0.17 or less (no SHGC requirement).

2. 1/4- or 1/2-Lite doors (about 50% glass or less) must have a U-factor of 0.25 or less and an SHGC of 0.25 or less.

3. 3/4- or Full-Lite doors (more than 50% glass) must have a U-factor of 0.30 or less and an SHGC of 0.40 or less.

4. U Value determined in accordance with NFRC 100 and SHGC in accordance with NRFC 200.

5. All exterior doors to be metal with metal frames.

B. Interior Doors.

1. Solid core wood door 3’-0” x 6’-8”

2. Steel Frame

3. Lever type handle on offices and conference/training rooms

4. Keypad on high security doors.

5. Interior Offices to have an 18” wide full-length sidelight window adjacent to the door.

1 .6 QUALITY ASSURANCE

A. Door Hardware Supplier Qualifications: Experienced commercial door hardware distributors with a minimum 5 years documented experience supplying both mechanical and electromechanical hardware installations comparable in material, design, and extent ...

B. Keying Conference: Conduct conference with Owner to incorporate the following criteria into the final keying schedule document:

1. Function of building, purpose of each area and degree of security required.

2. Plans for existing and future key system expansion.

3. Requirements for key control storage and software.

4. Installation of permanent keys, cylinder cores and software.

5. Address location and requirements for delivery of keys.

C. Commissioning:

1. The General Contractor in conjunction with the lock manufacturer’s representative, hardware installer and supplying distributor shall commission hardware.

a. Test door hardware operation with climate control system both at rest and while in full operation.

b. Test electrical and electronic hardware systems for satisfactory operation.

c. Test hardware interfaced with fire/life-safety system for proper operation and release.

1 .7 COMPLIANCE VERIFICATION

A. Specifications, design calculations and drawings shall be submitted during the design process as specified below and as specified in the Design Build SOW paragraphs “Schedule and Milestones”, “DBC Submission Requirements”, and “Design Requirements”...

1 .8 SUBMITTALS DURING CONSTRUCTION

A. Submit the following for review and approval in accordance with the Design Build SOW Paragraph “Submittals During Construction”.

B. Manufacturer’s Catalog Data:

1. Door hardware, with schedule:

a. Door Hardware Schedule: Prepared by or under the supervision of supplier, detailing fabrication and assembly of door hardware, as well as procedures and diagrams. Coordinate the final Door Hardware Schedule with doors, frames, and related work to e...

b. Details of electrified access control hardware indicating the following:

1) Wiring Diagrams: Upon receipt of approved schedules, submit detailed system wiring diagrams for power, signaling, monitoring, communication, and control of the access control system electrified hardware. Differentiate between manufacturer-installed...

a) Elevation diagram of each unique access controlled opening showing location and interconnection of major system components with respect to their placement in the respective door openings.

b) Complete (risers, point-to-point) access control system block wiring diagrams.

c) Wiring instructions for each electronic component scheduled herein.

2) Electrical Coordination: Coordinate with related sections the voltages and wiring details required at electrically controlled and operated hardware openings.

c. Keying Schedule: After a keying meeting with the owner has taken place prepare a separate keying schedule detailing final instructions. Submit the keying schedule in electronic format. Include keying system explanation, door numbers, key set symbol...

d. Source Limitations: Obtain each type and variety of door hardware specified in this section from a single source unless otherwise indicated.

1) Electrified modifications or enhancements made to a source manufacturer's product line by a secondary or third-party source will not be accepted.

2) Provide electromechanical door hardware from the same manufacturer as mechanical door hardware, unless otherwise indicated.

2. Lock box

C. Operation and Maintenance Data:

1. Doors.

2. Hardware.

D. Samples:

1. Paint color samples

2 PART 2 SYSTEM COMPONENTS

2 .1 GENERAL

A. Performance Requirements

1. Fire-Rated Door Assemblies: Assemblies complying with NFPA 80 that are listed and labeled by a qualified testing agency acceptable to authorities having jurisdiction for fire-protection ratings and temperature-rise limits indicated on Drawings, bas...

a. Smoke- and Draft-Control Door Assemblies: Listed and labeled for smoke and draft control by a qualified testing agency acceptable to authorities having jurisdiction, based on testing according to UL 1784 and installed in compliance with NFPA 105.

b. Temperature-Rise Limit: At vertical exit enclosures and exit passageways, provide doors that have a maximum transmitted temperature end point of not more than 450 deg F above ambient after 30 minutes of standard fire-test exposure.

2. Fire-Rated, Borrowed-Lite Assemblies: Complying with NFPA 80 and listed and labeled by a qualified testing agency acceptable to authorities having jurisdiction, for fire-protection ratings indicated, based on testing according to NFPA 257 or UL 9.

B. Clearances

1. Edge clearances between doors and frames: 1/8 inch.

2. At door sills with no threshold: 1/2 inch standard unless noted otherwise.

3. At door sills with threshold: 1/4 inch maximum between door and threshold.

4. At door sills at carpet: 1/4 inch higher than the thickness of the carpet.

5. Between meeting edges of pairs of doors: 1/8 inch

C. Identifying devices/signage:

1. Install signage in accordance with ADA and manufacturer's instructions.

2. Entry Glass Doors: Install vinyl die cut and reverse vinyl die cut letter signs on glazing on doors centered on doors at 54” above finished floor.

2 .2 GLAZING

A. Exterior Doors: 5/8" total, 1/4" laminated at exterior, 1/8" air space, 1/4" Low E laminated at interior.

B. Interior Doors: Laminated Glass of equal thicknesses (1/8" minimum) inner and outer faces of heat strengthened float glass laminated in autoclave under heat and pressure to a clear polyvinyl butyl sheet. Fabricate to produce glass free of foreign s...

C. Seal: Dual-seal consisting of butyl primary seal and silicone secondary seal required. Provide spacers filled with desiccant and bent or soldered corners to provide a sealed edge.

D. Provide flush integral stops on one side and flush screw on stops on the opposite side. This includes windows in doors. Provide removable stop at building interior of exterior windows and room side away from corridors at interior windows. Provide s...

1. Stiles and rails: Wide stile (5" nominal width). Construct the doors using 5" wide stiles, 7” top rail, and a solid 10" bottom rail.

2. Fasten to frame with metal screws at 18" o.c. maximum, flathead, countersunk. Do not over-tighten to cause indentations or puckering. Provide vandal proof screws at exterior stops when the drawings specifically require removable stops at the exterior.

2 .3 HOLLOW METAL DOORS AND FRAMES

A. General: Construct hollow-metal doors and frames to comply with standards indicated for materials, fabrication, hardware locations, hardware reinforcement, tolerances, and clearances, and as specified.:

B. Standard Steel Doors and Frames

1. Doors

a. Type: As indicated in the Door and Frame Schedule.

b. Thickness: 1-3/4 inches.

c. Face:

1) Exterior: Metallic-coated steel sheet, minimum 16 gauge (0.053”), with minimum G90 coating.

2) Interior: Metallic-coated steel sheet, minimum 16 gauge (0.053”).

d. Edge Construction: Model 2, Seamless.

e. Top Edge Closures: Close top edges of doors with flush closures of same material as face sheets. Seal joints against water penetration.

f. Bottom Edges: Close bottom edges of doors where required for attachment of weather stripping with end closures or channels of same material as face sheets. Provide weep-hole openings in bottoms of exterior doors to permit moisture to escape.

g. Core: Polystyrene and Vertical steel stiffener.

h. Fire-Rated Core: Manufacturer's standard vertical steel stiffener with insulation core for fire rated doors.

2. Frames

a. Materials:

1) Exterior: Metallic-coated steel sheet, minimum 14 gage (0.067”), with minimum G90 coating.

2) Interior: Metallic-coated steel sheet, minimum 16 gage (0.053”).

b. Construction: Fully welded and ground smooth.

c. Head reinforced for closer.

d. Exterior: Fill door jambs solid with rock wool.

3. Frame Anchors

a. Jamb Anchors:

1) Type: Anchors of minimum size and type required by applicable door and frame standard, and suitable for performance level indicated.

2) Quantity: Minimum of three anchors per jamb, with one additional anchor for frames with no floor anchor. Provide one additional anchor for each 24 inches of frame height above 7 feet.

3) Post-installed Expansion Anchor: Minimum 3/8-inch-diameter bolts with expansion shields or inserts, with manufacturer's standard pipe spacer

4) Floor Anchors: Provide floor anchors for each jamb and mullion that extends to floor.

b. Floor Anchors for Concrete Slabs with Underlayment: Adjustable-type anchors with extension clips, allowing not less than 2-inch height adjustment. Terminate bottom of frames at top of underlayment.

c. Material: ASTM A879/A879M, Commercial Steel (CS), 04Z coating designation; mill phosphatized.

1) For anchors built into exterior walls, steel sheet complying with ASTM A1008/A1008M or ASTM A1011/A1011M; hot-dip galvanized according to ASTM A153/A153M, Class B.

2 .4 FLUSH WOOD INTERIOR DOORS

A. General:

1. Quality Standard: In addition to requirements specified, comply with…