This document is an attached file related to a federal contract opportunity issued by the U.S. Department of Interior (DOI), U.S. Geological Survey. The opportunity is a Request for Quote (RFQ) for the MAINTENANCE OF SOUND BAR IN LOCK 19 WITH AN OPTION FOR REMOVAL. The solicitation number is 140G0225R0002. This is a full and open competition with the associated NAICS code of 237990 - Other Heavy and Civil Engineering Construction. Award will be made to the vendor whose quote is determined to be the most advantageous to the government. A site visit is scheduled. Quotes and questions must be submitted via email to the contracting officer. The anticipated award date is not provided.
View the file
Other files
Show all 17
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
BE Project No.
MISSISSIPPI RIVER BASIN
LOCK & DAM 19 - KEOKUK
GLRIAC ACOUSTIC STUDY
525 N WATER STREET
KEOKUK, IA 52632
17025-19-04License Renewal Date:
Drawn By:
Drawing No.
Drawing Title
Structural Engineer t 312.440.2300 f 312.440.2303 www.baileyedward.com
35 East Wacker Dr Suite 2800 Chicago, IL 60601-2308
08-07-2020 FINAL DESIGN
Issue Date Title
PROPERTY OF THE UNITED STATES GOVERMENT
COPYING, DISSEMINATION, OR DISTRIBUTION OF
THESE DRAWINGS, PLANS, OR SPECIFICATIONS TO
UNAUTHORIZED USERS IS PROHIBITED.
Do not remove this notice.
Properly destroy documents when no longer needed.
GEI CONSULTANTS OF MICHIGAN, P.C.
109 W. BARAGA AVENUE
MARQUETTE, MI 49855
(906)451-4021
Consultants
Pr int
D ate
/T im e:
8/1
8/2
0 9 :59
A M
USGS CONTRACT NO.:
140G0220F0140
C-101, S-001, S-101, S-301, S-302, S-310, S-501, S-502, S-503, S-504, S-505, S-506, S-507
(SIGNATURE) (DATE)
PRINTED OR TYPED NAME:
LICENSE NUMBER:
MY LICENSE RENEWAL DATE IS DECEMBER 31, 2021
22250
KENT W. LOCKE
PAGES OR SHEETS COVERED BY THIS SEAL:
08/07/2020
SEAL
G-001, G-002
I HEREBY CERTIFY THAT THESE DOCUMENTS HAVE BEEN PREPARED BY ME OR
UNDER MY DIRECT PERSONAL SUPERVISION AND THAT I AM A DULY LICENSED
REGISTERED ARCHITECT UNDER THE LAWS OF THE STATE OF IOWA.
(SIGNATURE) (DATE)
PRINTED OR TYPED NAME:
LICENSE NUMBER:
MY LICENSE RENEWAL DATE IS JUNE 30, 2022
03583
ELLEN B. DICKSON
PAGES OR SHEETS COVERED BY THIS SEAL:
08/07/2020
SEAL
I HEREBY CERTIFY THAT THESE ENGINEERING DOCUMENTS HAVE BEEN PREPARED
BY ME OR UNDER MY DIRECT PERSONAL SUPERVISION AND THAT I AM A DULY
LICENSED PROFESSIONAL ENGINEER UNDER THE LAWS OF THE STATE OF IOWA.
UNITED STATES GEOLOGICAL SURVEY
USGS CONTRACT NO.: 140G0220F0140
GLRIAC ACOUSTIC STUDY AT MISSISSIPPI RIVER BASIN
LOCK & DAM 19 - KEOKUK
TITLESHEET
GENERAL
G-001 COVER SHEET
G-002 SITE PLAN
C-101 SITE PLAN
STRUCTURAL
S-001 STRUCTURAL GENERAL NOTES
S-101 PLAN LOWER LOCK EMPTYING SYSTEM
S-301 SECTION LANDSIDE LOWER GUIDEWALL
S-302 SECTIONS
S-310 SECTIONS PICK POINT CONNECTION
S-501 DETAILS
S-502 DETAILS
S-503 DETAILS
S-504 DETAILS
S-505 DETAILS ANGLED BRACKET ASSEMBLY
S-506 DETAILS
S-507 DETAILS
S-508 DETAILS
S-509 DETAILS
S-510 DETAILS PICK POINTS ASSEMBLY
S-511 DETAILS
S-512 WELDMENT HYDROPHONE HOLDER
S-601 DIAGRAM
S-901 ISOMETRIC LOWER WALL
S-902 BOTTOM LAID HYDROPHONE & CONDUIT LOCATIONS
S-903 BOTTOM LAID HYDROPHONE CONDUIT DETAILS
S-904 HYDROPHONE BOTTOM LAID CONDUIT PIECES AND
INSTALLATION
S-905 LADDERWALL HYDROPHONE INSTALLATION DETAILS
S-906 FRAMING AND SUPPORT STRUCTURE DETAILS
ELECTRICAL
E-001 GENERAL ELECTRICAL NOTES
E-101 LOWER LANDWALL POWER PLAN
E-201 ELEVATION CORE DRILL PLACEMENT
E-301 SECTION CORE DRILL
TELEMETRY
T-100 TELEMETRY EQUIPMENT PLAN
T-101 TELEMETRY EQUIPMENT PLANS
T-102 TELEMETRY EQUIPMENT, JOB TRAILER INFORMATION
T-103 TELEMETRY EQUIPMENT
T-104 TELEMETRY FOR POWER MONITORING PLAN,
SCHEMATIC AND DETAILS
T-105 TELEMETRY IMAGES
T-106 TELEMETRY IMAGES
T-107 TELEMETRY IMAGES
NORTH
VICINITY LOCATION MAP INDEX OF DRAWINGS
KEOKUK, IA
COVER SHEET
G-001
NPT
NORTH
PROJECT SITE
S-508, S-509, S-510, S-511, S-512, S-601, S-901, S-902, S-903, S-904, S-905, S-906, E-001, E-101, E-201, E-301, T-101, T-101, T-102, T-103, T-104, T-105, T-106, T-107
LOCK & DAM 19 - KEOKUK
GLRIAC ACOUSTIC STUDY
525 N WATER STREET
KEOKUK, IA 52632
17025-19-04License Renewal Date:
Drawn By:
Drawing No.
Drawing Title
Structural Engineer t 312.440.2300 f 312.440.2303 www.baileyedward.com
35 East Wacker Dr Suite 2800 Chicago, IL 60601-2308
08-07-2020 FINAL DESIGN
Issue Date Title
PROPERTY OF THE UNITED STATES GOVERMENT
COPYING, DISSEMINATION, OR DISTRIBUTION OF
THESE DRAWINGS, PLANS, OR SPECIFICATIONS TO
UNAUTHORIZED USERS IS PROHIBITED.
Do not remove this notice.
Properly destroy documents when no longer needed.
GEI CONSULTANTS OF MICHIGAN, P.C.
109 W. BARAGA AVENUE
MARQUETTE, MI 49855
(906)451-4021
Consultants
Pr int
D ate
/T im e:
8/1
8/2
0 9 :59
A M
USGS CONTRACT NO.:
140G0220F0140
C-101, S-001, S-101, S-301, S-302, S-310, S-501, S-502, S-503, S-504, S-505, S-506, S-507
(SIGNATURE) (DATE)
PRINTED OR TYPED NAME:
LICENSE NUMBER:
MY LICENSE RENEWAL DATE IS DECEMBER 31, 2021
22250
KENT W. LOCKE
PAGES OR SHEETS COVERED BY THIS SEAL:
08/07/2020
SEAL
G-001, G-002
I HEREBY CERTIFY THAT THESE DOCUMENTS HAVE BEEN PREPARED BY ME OR
UNDER MY DIRECT PERSONAL SUPERVISION AND THAT I AM A DULY LICENSED
REGISTERED ARCHITECT UNDER THE LAWS OF THE STATE OF IOWA.
(SIGNATURE) (DATE)
PRINTED OR TYPED NAME:
LICENSE NUMBER:
MY LICENSE RENEWAL DATE IS JUNE 30, 2022
03583
ELLEN B. DICKSON
PAGES OR SHEETS COVERED BY THIS SEAL:
08/07/2020
SEAL
I HEREBY CERTIFY THAT THESE ENGINEERING DOCUMENTS HAVE BEEN PREPARED
BY ME OR UNDER MY DIRECT PERSONAL SUPERVISION AND THAT I AM A DULY
LICENSED PROFESSIONAL ENGINEER UNDER THE LAWS OF THE STATE OF IOWA.
UNITED STATES GEOLOGICAL SURVEY
USGS CONTRACT NO.: 140G0220F0140
GLRIAC ACOUSTIC STUDY AT MISSISSIPPI RIVER BASIN
LOCK & DAM 19 - KEOKUK
TITLESHEET
GENERAL
G-001 COVER SHEET
G-002 SITE PLAN
C-101 SITE PLAN
STRUCTURAL
S-001 STRUCTURAL GENERAL NOTES
S-101 PLAN LOWER LOCK EMPTYING SYSTEM
S-301 SECTION LANDSIDE LOWER GUIDEWALL
S-302 SECTIONS
S-310 SECTIONS PICK POINT CONNECTION
S-501 DETAILS
S-502 DETAILS
S-503 DETAILS
S-504 DETAILS
S-505 DETAILS ANGLED BRACKET ASSEMBLY
S-506 DETAILS
S-507 DETAILS
S-508 DETAILS
S-509 DETAILS
S-510 DETAILS PICK POINTS ASSEMBLY
S-511 DETAILS
S-512 WELDMENT HYDROPHONE HOLDER
S-601 DIAGRAM
S-901 ISOMETRIC LOWER WALL
S-902 BOTTOM LAID HYDROPHONE & CONDUIT LOCATIONS
S-903 BOTTOM LAID HYDROPHONE CONDUIT DETAILS
S-904 HYDROPHONE BOTTOM LAID CONDUIT PIECES AND
INSTALLATION
S-905 LADDERWALL HYDROPHONE INSTALLATION DETAILS
S-906 FRAMING AND SUPPORT STRUCTURE DETAILS
ELECTRICAL
E-001 GENERAL ELECTRICAL NOTES
E-101 LOWER LANDWALL POWER PLAN
E-201 ELEVATION CORE DRILL PLACEMENT
E-301 SECTION CORE DRILL
TELEMETRY
T-100 TELEMETRY EQUIPMENT PLAN
T-101 TELEMETRY EQUIPMENT PLANS
T-102 TELEMETRY EQUIPMENT, JOB TRAILER INFORMATION
T-103 TELEMETRY EQUIPMENT
T-104 TELEMETRY FOR POWER MONITORING PLAN,
SCHEMATIC AND DETAILS
T-105 TELEMETRY IMAGES
T-106 TELEMETRY IMAGES
T-107 TELEMETRY IMAGES
NORTH
VICINITY LOCATION MAP INDEX OF DRAWINGS
KEOKUK, IA
COVER SHEET
G-001
NPT
NORTH
PROJECT SITE
S-508, S-509, S-510, S-511, S-512, S-601, S-901, S-902, S-903, S-904, S-905, S-906, E-001, E-101, E-201, E-301, T-101, T-101, T-102, T-103, T-104, T-105, T-106, T-107 weaton Text Box
LEGEND
Deletions are in Red Additions are in Green Notes are in Blue
GENERAL STAGING
JOB TRAILER
LOCATION OF CRANE
APPROXIMATE LOCATION OF
LAST DISCHARGE LATERAL.
90 FEET DOWNSTREAM OF
LOWER GATE PINTLE.
LOCATION OF WELDMENT
WITH TRANSDUCERS AND
HYDROPHONES
LOCATION OF CORE
DRILL MACHINE
USACE TO RELOCATE
METAL GATES TO MAKE
ROOM FOR JOB TRAILER
SEE T-103, IMAGE 9
SEE T-104, IMAGE 3
DECK BOX
WELDMENT LENGTH =
104'-8 18" (SHEET S-502)
SEE T-100, T-101 FOR TELEMETRY PLANS
AND HYDROPHONE LOCATIONS
DECK BOX22
DECK BOX22
SITE PLAN
SCALE : 1" = 150'-0"
NORTH
DECK BOX18
DECK BOX 22
2A
2A
2A
BE Project No.
MISSISSIPPI RIVER BASIN
LOCK & DAM 19 - KEOKUK
GLRIAC ACOUSTIC STUDY
525 N WATER STREET
KEOKUK, IA 52632
17025-19-04License Renewal Date:
Drawn By:
Drawing No.
Drawing Title
Structural Engineer t 312.440.2300 f 312.440.2303 www.baileyedward.com
35 East Wacker Dr Suite 2800 Chicago, IL 60601-2308
08-07-2020 FINAL DESIGN
Issue Date Title
PROPERTY OF THE UNITED STATES GOVERMENT
COPYING, DISSEMINATION, OR DISTRIBUTION OF
THESE DRAWINGS, PLANS, OR SPECIFICATIONS TO
UNAUTHORIZED USERS IS PROHIBITED.
Do not remove this notice.
Properly destroy documents when no longer needed.
GEI CONSULTANTS OF MICHIGAN, P.C.
109 W. BARAGA AVENUE
MARQUETTE, MI 49855
(906)451-4021
Consultants
Pr int
D ate
/T im e:
8/6
/20
1:
P M
USGS CONTRACT NO.:
140G0220F0140
SITE PLAN
G-002
NPT
Chris Donaldson
Chris Donaldson
Chris Donaldson
Chris Donaldson
ADD DECK BOX
Chris Donaldson
DELETE
Chris Donaldson
75 - ANCHOR BOLTS - AB100
BILL OF MATERIAL
MARK QTY DESCRIPTION LENGTH WEIGHT REMARKS
AB100 75
P1009 75 ROD1/2" 0'-6" 25 MILL FINISH A36
SQ-2ANCHOR BOLTS
75 1/2_HEAVY_HEX_NUT 5
75 1/2_WASHER 2
TOTAL WEIGHT THIS DRAWING 25
SHOP NOTES :
1. TOLERANCE ON ALL DIMENSIONS ± 1/16".
2. CHECK SQUARENESS OF ALL CORNERS.
3. DOUBLE CHECK FLATNESS OF PLATES AFTER WELDING.
4. CHECK STRAIGHTNESS OF RAILS AFTER WELDING.
Location :
Detailer :
Checker:
Date :
Project :
Drawing No. :
Phase :
Date :
Client :
Project No :
W.O.# :SKV
YMM
KEOKUK, IA
JF Brennan
COE LOCK - 19
12/14/2020
12/14/2020
23849
AB100
A
5. RAIL WELD FINISH TO BE NOMMA #3
12/14/2020A ISSUED FOR APPROVAL
REV DESCRIPTION DATE
TR
EA
D
8/
8/
R
O D
1 2/ X weaton Line weaton Line weaton Cloud+ weaton Cloud+ Replaced with 1/2"x7" Power-Stud + SD1, per RFI 004.
LOCK & DAM 19 - KEOKUK
GLRIAC ACOUSTIC STUDY
525 N WATER STREET
KEOKUK, IA 52632
17025-19-04License Renewal Date:
Drawn By:
Drawing No.
Drawing Title
Structural Engineer t 312.440.2300 f 312.440.2303 www.baileyedward.com
35 East Wacker Dr Suite 2800 Chicago, IL 60601-2308
08-07-2020 FINAL DESIGN
Issue Date Title
PROPERTY OF THE UNITED STATES GOVERMENT
COPYING, DISSEMINATION, OR DISTRIBUTION OF
THESE DRAWINGS, PLANS, OR SPECIFICATIONS TO
UNAUTHORIZED USERS IS PROHIBITED.
Do not remove this notice.
Properly destroy documents when no longer needed.
GEI CONSULTANTS OF MICHIGAN, P.C.
109 W. BARAGA AVENUE
MARQUETTE, MI 49855
(906)451-4021
Consultants
Pr int
D ate
/T im e:
8/6
/20
1:
P M
USGS CONTRACT NO.:
140G0220F0140
SITE PLAN
C-101
XXX
Chris Donaldson Brown Electric Job Trailer
Chris Donaldson
Chris Donaldson
Chris Donaldson JF Brennan Job Trailer
Chris Donaldson
Dumpster
GENERAL ELECTRICAL NOTES GENERAL ELECTRICAL WORK
1. CONTRACTOR MUST COORDINATE WITH AND RECEIVE APPROVAL
FROM THE CONTRACTING OFFICER PRIOR TO ANY ELECTRICAL
POWER OUTAGES.
2. PRIOR TO ANY CONCRETE EXCAVATION WORK, THE
CONTRACTOR MUST PROVIDE LOCATE SERVICES IN WORK
AREAS, MARK ELECTRICAL DUCTS USING MARKER PAINT, AND
PROVIDE PHOTO AND VIDEO FILES OF PAINT LOCATORS TO
GOVERNMENT. PROVIDE SKETCHES WITH MEASUREMENTS FROM
LOCKWALL AND OTHER PERMANENT REFERENCE POINTS TO ADD
AS BUILT DRAWINGS FOR THIS PROJECT.
3. CONTRACTOR MUST PROVIDE PROTECTION FROM OPEN
MANHOLES IN ACCORDANCE WITH THE SAFETY AND HEALTH
REQUIREMENTS MANUAL EM 385-1-1 DATED 30 NOVEMBER, 2014,
SECTION 11, SUBSECTION J.
4. CONTRACTOR MUST ADHERE TO PROPER LOCKOUT/TAG OUT
PROCEDURES IN ACCORDANCE WITH THE SAFETY AND HEALTH
REQUIREMENTS MANUAL EM 385-1-1 DATED 30 NOVEMBER, 2014,
SECTION 12.
5. ANY DAMAGE TO DUCT BANK, EMBEDDED CONDUITS OR CABLES,
OR ANY LOCK EQUIPMENT BY THE CONTRACTOR (OTHER THAN
AS INDICATED IN PLANS) MUST BE REPAIRED AT THE
CONTRACTOR'S EXPENSE.
6. ANY PERMANENT CABLES DAMAGED BY THE CONTRACTOR MUST
BE REPLACED IN ITS ENTIRETY FROM SOURCE TO LOAD AT THE
CONTRACTOR'S EXPENSE.
7. A SPLICE CAP IS A TERM USED TO DESCRIBE BLIND ENDED
SHRINK MATERIAL WHICH CAN BE PLACED OVER THE END OF THE
BARE CONDUCTORS AND A CABLE END TO INSULATE FROM
ELECTRIC SHOCK AND TO PROTECT THE CABLE AND CONDUCTOR
ENDS FROM WATER INTRUSION. SPLICE CAPS MUST BE
INSTALLED TO PROTECT THE ENDS OF NON TERMINATED CABLES
OR CONDUCTORS. ONE EXAMPLE LOCATION FOR THIS USE WILL
BE THE LOWER GUIDEWALL CABLES TO BE PROTECTED AND
TERMINATED TO NEW CABLES.
8. STAGING OF EQUIPMENT REMOVAL, RELOCATION, AND
INSTALLATION MUST BE COORDINATED WITH THE CONTRACTING
OFFICER TO ALLOW ACCESS TO NECESSARY UPPER LOCK WALL
AREAS BY THE LOCK AND DAM OPERATING PERSONNEL.
9. THE CONTRACTOR MUST BE AWARE AND CONSIDER THAT THERE
ARE OCCASIONS WHEN THE RIVER MAY FLOOD AND WATER MAY
OVERTOP THE LOCK WALL, AND CARE MUST BE TAKEN TO
PROTECT CABLE ENDS FROM BEING SUBMERGED.
10. ALL FEATURES OF ELECTRICAL WORK AND INSTALLATION MUST
BE IN ACCORDANCE WITH THE LATEST EDITION OF NFPA 70,
NATIONAL ELECTRICAL CODE AND USACE 385-1-1.
11. THE ELECTRICAL WORK MUST BE COORDINATED WITH THE
STRUCTURAL CONCRETE WORK TO FACILITATE STRUCTURAL
CONSTRUCTION. SEE STRUCTURAL DRAWINGS.
12. THE CONTRACTOR MUST COORDINATE ALL EQUIPMENT
LOCATIONS PRIOR TO MAKING THE ACTUAL ELECTRICAL
INSTALLATION.
13. ALL NEW ELECTRICAL EQUIPMENT MUST BE UL LISTED.
14. ALL CABLE ROUTING SHALL BE SUBMITTED FOR GOVERNMENT
APPROVAL.
15. ROUTING OF SENSOR /HYDROPHONE CABLES ALONG THE LOCK
WALL, WHETHER EXPOSED OR RUN IN PROTECTIVE CONDUIT,
SHALL BE SECURED TO THE MIDDLE HAND RAIL WHERE POSSIBLE,
AND NOT SECURED TO THE TOP RAIL, AND SHALL USE ALUMINUM
ZIP TIES.
16. ALL NEW INSTALLED EQUIPMENT INCLUDING, BUT NOT LIMITED
TO: CONDUIT, WIRE, CABLES, ENCLOSURES, COVERS,
RECEPTACLES, SWITCHES, GROUNDING EQUIPMENT, TERMINALS,
TERMINATORS, AND WIRE LABELS MUST COMPLY WITH RELEVANT
AMERICAN INDUSTRY STANDARDS (NEMA, ANSI, ETC.).
17. NEW CONDUCTORS MUST BE COPPER, 600 VOLT, 90 DEGREE
CELSIUS, TYPE THHN/THWN-2 INSULATION. USE SOLID FOR #10
AWG AND SMALLER, AND STRANDED FOR #8 AWG AND LARGER.
MINIMUM CONDUCTOR SIZE SHALL BE #12 AWG, AND MINIMUM
CONDUIT SIZE SHALL BE 3/4 INCH RIGID GALVANIZED STEEL
CONDUIT.
18. PROVIDE SUPPORT AT EACH BOX. PROVIDE AN ADDITIONAL
CONDUIT SUPPORT WITHIN 3 FEET OF EACH BOX AND FITTING.
USE STRAP TYPE CONDUIT SUPPORTS FOR EXPOSED CONDUITS.
CONDUIT MUST NOT BE SUPPORTED BY OTHER CONDUIT,
EQUIPMENT, MACHINERY, OR PIPING.
19. NAMEPLATES FOR NEW PANEL BOARDS, JUNCTION BOXES,
TERMINAL BLOCKS, AND NEW EQUIPMENT, MUST BE UV RATED
ENGRAVED PLASTIC WITH 3/16 INCH HIGH LETTER TO IDENTIFY
ALL MAJOR PIECES OF ELECTRICAL EQUIPMENT BY NAME AND
FUNCTION INCLUDING OPERATING VOLTAGE, AND MAXIMUM FUSE
SIZE (IF APPLICABLE). LABELING SWITCH AS S-A, S-B, ETC., DOES
NOT SATISFY THIS REQUIREMENT. USE NON-FERROUS SCREWS
TO ATTACH NAMEPLATES.
20. PROVIDE INSULATING BUSHINGS AT TERMINATION OF CONDUITS
AT ALL ELECTRICAL ENCLOSURES, BOXES, AND HAND HOLES.
21. INSULATED THROAT GROUNDING TYPE CONDUIT HUBS SHALL BE
USED TO FASTEN CONDUIT TO ELECTRICAL JUNCTION BOXES.
22. WEDGE TYPE CONCRETE ANCHORS AND POWDER ACTUATED
CONCRETE ANCHORS ARE NOT PERMITTED.
23. THE GOVERNMENT HAS FINAL APPROVAL ON ALL EQUIPMENT
LOCATIONS AND CONDUIT ROUTING.
24. ALL CONDUCTORS MUST BE INSTALLED IN RACEWAY, EXCEPT
WHERE NOTED OTHERWISE .
25. AS BUILT DRAWINGS: CONTRACTOR MUST INCLUDE DETAILED
LOCATIONS AND PLAN SKETCHES OF ALL CABLE SPLICES,
CONDUITS, AND CABLES ASSOCIATED WITH THIS CONTRACT ON
RED LINE AS BUILT DRAWINGS. SEE SPECIFICATIONS FOR
FURTHER REQUIREMENTS.
26. THE EXISTING ELECTRICAL DRAWINGS INDICATE GENERAL
ELECTRICAL CONDITIONS. THE CONTRACTOR MUST FIELD VERIFY
EXISTING CONDITIONS AND DOCUMENT CHANGES THAT MAY
EFFECT INSTALLATION OR OPERATION.
27. REFERENCE DRAWINGS ARE DRAWINGS OF RECORD INCLUDED
SOLELY FOR THE CONTRACTOR'S BENEFIT. NO REQUIRED WORK
ON THIS CONTRACT IS SHOWN ON THE REFERENCE DRAWINGS.
THE REFERENCE DRAWINGS ARE NOT "AS BUILT" SO THEY DO
NOT NECESSARILY REPRESENT ACTUAL FIELD CONDITIONS.
REFERENCE DRAWINGS ARE NOT PRINTED TO SCALE.
GENERAL ELECTRICAL WORK NOTES:
28. NORMAL OPERATION OF THE LOCK, BY LOCK PERSONNEL, SHALL
BE MAINTAINED AT ANY TIME EXCEPT DURING NAVIGATION SHUT
DOWN UNLESS OTHERWISE COORDINATED AND AGREED UPON IN
WRITING. ANY POWER OUTAGE SHALL BE COORDINATED WITH
THE CONTRACTING OFFICER PRIOR TO PERFORMANCE OF WORK.
29. THE CONTRACTOR SHALL ROUTE TEMPORARY ELECTRIC CABLES
ACROSS PATHWAYS SO THAT THEY ARE PHYSICALLY PROTECTED
IN ACCORDANCE WITH EM385-1-, NFPA 70, AND IEEE/ANSIC21 FOR
SAFE ROUTING.
30. WHERE ELECTRIC CABLING IS SUBJECT TO CROSSING BY
PEDESTRIANS, CONSTRUCTION EQUIPMENT, AND BY CUSHMAN
CARTS, TEMPORARY CABLING SHALL BE ROUTED OVERHEAD NOT
LESS THAN 8 FEET ABOVE GRADE UNLESS OTHERWISE
APPROVED BY THE CONTRACTING OFFICER, OR PROTECTED BY A
TEMPORARY BRIDGE.
31. TEMPORARY BRIDGES FOR CABLE PROTECTION SHALL BE
CONSTRUCTED TO ACCOMMODATE CONSTRUCTION EQUIPMENT
AND CUSHMAN CARTS UP TO A 2000 LB MAXIMUM LOAD OR 1000
LB LOAD PER AXLE. CONSTRUCTION OF THE TEMPORARY BRIDGE
SHALL NOT IMPEDE MOTORIZED OPERATION OF THE CARTS UP
AND OVER THE BRIDGE, AND IT SHALL NOT ALLOW THE TO CART
TO BOTTOM OUT OR HANG UP.
32. ELECTRICAL NOTES ARE INTENDED TO INDICATE THE SCOPE OF
WORK REQUIRED, AND DO NOT INDICATE EVERY BOX, CONDUIT
OR WIRE THAT MUST BE REMOVED OR INSTALLED.
33. AS REQUIRED COORDINATED, INSTALL NEW PANELBOARD WITH
CONDUIT AND CONDUCTORS TO SOURCE AND LOADS.
RECONNECT EXISTING SHED LOADS TO NEW PANELBOARD.
34. INSTALL NEW SPEAKER /SENSOR CABLE SUPPORTS WHERE
REQUIRED ALONG HAND RAIL, INCLUDING STRAIN RELIEF OVER
VERTICAL CORE-DRILL AND WHERE CABLES ARE SUPPORTED BY
MIDDLE HAND RAIL ON THE LOWER INTERMEDIATE LOCKWALL.
35. MAINTAIN SITE ACCESS FOR THE LOCK PERSONNEL AND
EQUIPMENT AT ALL TIMES.
36. REFERENCE DRAWINGS ARE DRAWINGS OF RECORD INCLUDED
SOLELY FOR THE CONTRACTOR'S BENEFIT. NO REQUIRED WORK
ON THIS CONTRACT IS SHOWN ON THE REFERENCE DRAWINGS.
THE REFERENCE DRAWINGS ARE NOT "AS BUILT" SO THEY DO
NOT NECESSARILY REPRESENT ACTUAL FIELD CONDITIONS.
REFERENCE DRAWINGS ARE NOT PRINTED TO SCALE.
37. STAGING OF EQUIPMENT, REMOVAL, RELOCATION, AND
INSTALLATION MUST BE COORDINATED WITH THE CONTRACTING
OFFICER TO ALLOW ACCESS TO NECESSARY UPPER LOCK WALL
AREAS BY LOCK AND DAM PERSONNEL.
DEMO NOTES:
1. ITEMS (I.E., TRANSFORMER, LOAD CENTER, ETC.) INDICATED TO BE
REMOVED AND NOT NOTED AS REUSED OR DELIVERED TO THE
CONTRACTING OFFICER SHALL BE REMOVED FROM THE SITE AND
PROPERLY DISPOSED OF BY THE CONTRACTOR.
DUCT BANK AND EMBEDDED CONDUITS LOCATION PROCEDURE
2. THE DUCT BANK (CABLE) AND EMBEDDED CONDUITS LOCATION
CONTRACTOR SHALL HAVE A MINIMUM OF 5 YEARS EXPERIENCE WITH
LOCATING BURIED UTILITIES USING MAGNETIC SIGNATURE LOCATION
EQUIPMENT.
3. CONTRACTOR SHALL USE A COMMERCIALLY AVAILABLE LOCATING
DEVICE TO LOCATE DUCT BANK AND EMBEDDED CONDUITS IN AREA OF
CONSTRUCTION BY ONE OF TWO METHODS. THE LEAST INTRUSIVE
METHOD IS THE “INDUCTIVE COUPLER” METHOD WHERE THE INDUCTIVE
COUPLER, ASSOCIATED WITH LOCATOR, CLAMPS AROUND CABLE TO
INDUCE A SIGNAL IN THE CABLE CONDUCTORS. THE CABLE CAN BE LEFT
CONNECTED TO ITS SOURCE AND LOAD DURING THIS PROCEDURE.
4. THE MORE RELIABLE METHOD IS THE APPLICATION OF SIGNAL, DIRECT
CONNECT” METHOD. THIS ENTAILS DISABLING POWER, DISCONNECTING
THE CABLES FROM THEIR POWER SOURCE, AND DIRECTLY CONNECTING
THE SIGNAL SOURCE TO ONE OF THE CONDUCTORS IN EACH CABLE TO
BE LOCATED.
5. THE ADJACENT MANHOLE OR HANDHOLE SHALL BE OPENED TO ACCESS
THE CABLES AND TO VERIFY DUCT BANK AND EMBEDDED CONDUITS
LOCATION AS A CHECK THAT THE LOCATOR IS IN FACT DETECTING THE
CABLES.
6. VARY SIGNAL FREQUENCIES AS REQUIRED TO ACHIEVE OPTIMUM
LOCATING SIGNAL. APPLY SIGNALS TO THE TWO OUTERMOST UPPER
CABLES IN THE DUCT BANK. THE AREA TO BE SCANNED FOR THE DUCT
BANK AND EMBEDDED CONDUIT LOCATION SHALL BE THE TOP OF THE
LOCK WALL DOWNSTREAM OF THE FIRST HAND-HOLE DOWNSTREAM OF
THE CONCRETE STAIRS THAT LEAD TO THE LOWER GUIDEWALL IN THE
AREA OF THE VERTICAL CORE DRILL.
7. MARK THE OUTER BOUNDARIES OF THE DUCT BANK AND EMBEDDED
CONDUIT LOCATION WITH AN ENVIRONMENTALLY FRIENDLY BRIGHT
MARKING PAINT WHICH WILL BE VISIBLE TO THE CONTRACTOR
PERFORMING THE CONCRETE EXCAVATION.
8. THE CONTRACTOR SHALL SUBMIT, FOR GOVERNMENT APPROVAL, A
TRANSMITTAL SPECIFYING THE DETAILS OF HOW THE DUCT BANK WAS
LOCATED AND THE LOCATION OF THE DUCT BANK PRIOR TO THE
BEGINNING OF ANY CONSTRUCTION IN THE AREA. INCLUDE A MINIMUM
OF 4 PHOTOS TAKEN FROM DIFFERENT ASPECTS CLEARLY SHOWING THE
PAINED DUCT BANK LOCATION ON TOP OF THE LOCK WALL. EMPHASIS
SHALL BE PLACED ON TAKING PHOTOS OF THE PAINTED DUCT BANK
LOCATION IN RELATION TO THE HAND-RAIL AND HAND HOLE.
9. EMPTY CONDUITS (EC) SHALL BE LOCATED VIA CONTRACTOR PULLING IN
A TEST CABLE AS A CONDUCTOR FOR THE CABLE LOCATION EQUIPMENT.
10. ELECTRICAL WORK WILL INCLUDE BUT IS NOT LIMITED TO:
LANDWALL POWER:
11. TEMPORARY POWER FOR ACOUSTIC TEST TRAILER: CONTRACTOR IS
RESPONSIBLE TO INCUR ALL COSTS ASSOCIATED WITH SIZING AND
PROVIDING A TEMPORARY 120/240V SINGLE PHASE SERVICE TO THE
TRAILER.
THE CONTRACTOR SHALL PROVIDE KWH (KILOWATT HOUR) METER FOR
MEASUREMENT OF POWER FED TO THE TRAILER. THE METER SHALL BE
LOCATED INSIDE THE STORAGE SHED NEAR THE NEW CIRCUIT
PROTECTION FOR THE TRAILER. REPLACE EXISTING 10KVA, 120/240V
TRANSFORMER AND 4-CIRCUIT "LIGHTING PANEL" WITH NEW LARGER
TRANSFORMER AND 30 CIRCUIT, 120/240V LOAD CENTER, RECONNECT
EXISTING LOADS, AND INSTALL KWH METER TO 2-POLE (3 WIRE +
GROUND) CIRCUIT THAT FEEDS THE TRAILER. A/E IS RESPONSIBLE FOR
SIZING TRANSFORMER, PANELBOARD, AND BRANCH CIRCUIT FEEDER TO
TRAILER. REFER TO ONE LINE DIAGRAM AND PANEL SCHEDULE ON
SHEET E-101.
ANY NEW BUILDING PENETRATIONS FOR CABLING OUT OF THE STORAGE
SHED SHALL BE AS HIGH ABOVE LOCKWALL AS PRACTICAL TO BE OUT OF
THE FLOODPLAIN, USE CONDUIT FOR CABLE PROTECTION AND BUILDING
WALL PENETRATION SHALL BE SEALED WATER TIGHT.
12. A POWER PLAN INCLUDING ONE-LINE DIAGRAM, CABLE ROUTING AND
BUILDING PENETRATION SEALING SHALL BE SUBMITTED FOR
GOVERNMENT APPROVAL.
13. SPONSOR SHALL REIMBURSE USACE FOR ELECTRICAL USAGE THROUGH
ENTIRE ACOUSTIC TEST PERIOD.
I-WALL POWER:
14. UTILIZE THE EXISTING EXISTING 20A CONVENIENCE RECEPTACLE
CIRCUIT ON LOCAL LIGHT POLE TO FEED POWER TO THE DECK BOX'S
LAPTOPS AND EXTERNAL HARD DRIVE.
15. UPON COMPLETION OF THE (APPROXIMATE) 3-YEAR PROJECT, ERDC IS
RESPONSIBLE FOR REMOVAL OF THE TRAILER, UTILITY POWER SOURCE
(IF INSTALLED), THE SECONDARY FEEDER CABLES, SPEAKER AND
SENSOR CABLES AND ALL RELATED MOUNTING EQUIPMENT. THE KWH
METER, TRANSFORMER, AND PANELBOARD (IF INSTALLED) ARE TO
REMAIN AS INSTALLED AT THE END OF THE PROJECT TEST. SEE ALSO
NOTE 15B AND NOTES ON SHEET C-101.
CONSTRUCTION SEQUENCE:
16A. WORK THAT SHOULD BE SUBSTANTIALLY COMPLETE BEFORE THE
BEGINNING OF THE NAVIGATION CLOSURE PERIOD AND READY FOR
CONTINUED INSTALLATION:
• ASSEMBLE SPEAKER WIRING AND SECURE CABLE STRAIN RELIEF
TO MOUNTING DEVICE PRIOR TO INSTALLATION TO THE BOTTOM OF
THE CHAMBER
• PERMANENTLY LABEL EACH CABLE ON NEAR THE ENDS THAT WILL
EVENTUALLY BE CONNECTED TO EQUIPMENT IN THE TRAILER.
16B. REMAINING WORK MUST BE COMPLETED AFTER THE ACOUSTICAL TEST
PERIOD INCLUDING BUT NOT LIMITED TO:
• REMOVE ALL ASSOCIATED HARDWARE AND EQUIPMENT
ASSOCIATED WITH SPEAKER AND SENSOR CABLING PROTECTION,
RACEWAY, AND SUPPORTS.
• CUT AND GRIND FLUSH ANY CONCRETE ANCHOR BOLTS
• INSTALL CAP ON STORAGE BUILDING PENETRATION CONDUIT
• FILL CORE DRILLED HOLES IN LOCKWALL WITH NON-SHRINK GROUT.
• ANY CONCRETE ENCASED CONDUITS ON TOP OF LOCKWALL, OR
UNDER SIDEWALKS THAT ARE NOT IMPEDING TRAFFIC OR CAUSING
A TRIP HAZARD MAY BE ABANDONED IN PLACE AS APPROVED IN
WRITING BY THE GOVERNMENT.
SPEAKER AND SENSOR WIRING:
17A. THE PLUGS THAT CONNECT THE CABLES TO THE SPEAKERS ARE NOT
WET-MATEABLE. THEREFORE ALL CABLING MUST BE ASSEMBLED IN THE
DRY (TOP-SIDE) PRIOR TO SUBMERSION.
17B. EACH CABLE SHALL HAVE WATER-PROOF LABELS INSTALLED INDICATING
WHICH SPEAKER OR SENSOR IT IS CONNECTED TO, SO THAT WHEN THE
CABLES ARE PULLED BACK UP THRU THE CORE-DRILLED HOLE, THE
PROPER CONNECTORS AND LABELS CAN BE RE-AFFIXED TO EACH CABLE
AT THE END POINT OF CONNECTION IN THE ERDC TRAILER.
17C. STRAIN-RELIEF: AS PART OF THE INITIAL TOP-SIDE ASSEMBLY, EACH
CABLE MUST HAVE ITS OWN STRAIN RELIEF AT EACH SPEAKER, OR
BUNDLES OF CABLES MUST HAVE STRAIN RELIEF ANCHORED TO THE
LAND-SIDE OF THE SUPPORT TUBE SUCH THAT WHEN THE CABLES ARE
PULLED TOP SIDE, THEY WILL NOT PULL THE PLUGS OUT OF EACH
SPEAKER OR DEVICE.
17D. CABLE INSTALLATION: IT IS RECOMMENDED THAT BUNDLES OF 4 OR 5
CABLES ARE CAPPED TOGETHER WITH A SEALING PULLING EYE THAT
WILL EVENTUALLY BE CUT OFF WHEN IT IS PULLED OUT TOP. IT IS ALSO
SUGGESTED DURING INSTALLATION THAT THE DIVER HELPS FEED THE
BUNDLES IN STAGGERED FASHION SUCH THAT THEY TAKE UP LESS
ROOM ON THE WAY UP THE CORE-DRILL HOLE, AND ALL CABLES ARE
ESSENTIALLY PULLED UP AT THE SAME TIME IN ATTEMPT TO LIMIT CABLE
TWISTING AND PROVIDE A SMOOTHER PULL.
17E. CABLE STRAIN-RELIEF: UPON INSTALLATION OF SPEAKER AND SENSOR
CABLES UP THRU THE CORE-DRILL HOLE, PROVIDE STRAIN RELIEF AT
THE HOLE ATOP THE LOCKWALL AND MAY BE ANCHORED TO THE HAND
RAIL. AGAIN, THE KELUMS GRIP STYLE STRAIN RELIEF MAY BE EASIEST
TO INSTALL ON "BUNDLES" OF 4 OR 5 CABLES HERE.
17F. CORE-DRILL HOLES: WHERE THE 16" HOLE MATES UP WITH THE 8" HOLE,
THERE WILL LIKELY BE A SHARP CONCRETE EDGE THAT THE CABLES
WILL NEED TO BE PULLED AROUND. IT IS RECOMMENDED THAT SOME
MEANS OF PROTECTING THE CABLES FROM DAMAGE AS THEY ARE
PULLED AROUND THAT CORNER IS USED, LIKE INSTALLING A 8" PVC
ELBOW WITH A SHORT SECTION OF PIPE INSERTED INTO THE 16" CORE,
AND SECURE THE PIPE TO THE CONCRETE, AND PROVIDE A BUSHING
FOR THE INSIDE EDGE OF THE PIPE TO KEEP ANY SHARP EDGES OF THE
PVC PIPE FROM DAMAGING THE CABLE WHERE THE DIVER WILL FEED
THE CABLES INTO THE PIPE. IT IS ALSO RECOMMENDED TO INSTALL A
RUBBER PROTECTIVE 'BUSHING' AROUND THE TOP OF THE CONCRETE
HOLE TO PROTECT THE CABLES WHERE THEY EXIT THE 8" CORE HOLE.
18. ALL CABLE ROUTING SHALL BE SUBMITTED FOR GOVERNMENT
APPROVAL.
19. ROUTING OF INDIVIDUAL SENSOR /HYDROPHONE CABLES ALONG THE
LOCK WALL CHAMBER OR I-WALL, WHETHER EXPOSED OR RUN IN
PROTECTIVE CONDUIT, SHALL BE SECURED TO THE MIDDLE HAND RAIL
WHERE POSSIBLE, AND NOT SECURED TO THE TOP RAIL, AND SHALL USE
ALUMINUM ZIP TIES.
FLOOD CONDITION - USGS ACTIONS
WHEN RENTING TRAILER, MAKE SURE RENTAL COMPANY
OFFERS 24 HOUR REMOVAL SERVICE IN CASE OF A FLOOD.
POWER DOWN ALL EQUIPMENT INSIDE THE TRAILER.
SECURE/REMOVE ALL EQUIPMENT INSIDE TRAILER AS
REQUIRED.
TURN DISCONNECT SWITCH OFF THAT PROVIDE POWER TO THE
TRAILER.
UN-PLUG POWER FROM TRAILER AND SECURE WIRING TO THE
WALL OF TIN BUILDING.
DISCONNECT ALL HYDROPHONE WIRING AND SPEAKER WIRING
INSIDE THE TRAILER, COIL THE WIRING UP AND SECURE IT TO
THE CONCRETE WALL.
RENTAL COMPANY TO REMOVE THE TRAILER.
REMOVE ALL DECK BOXES ON LOWER RIVER WALL AND LOWER
LAND WALL.
SECURE WIRING TO LIGHT POLE.
BE Project No.
MISSISSIPPI RIVER BASIN
LOCK & DAM 19 - KEOKUK
GLRIAC ACOUSTIC STUDY
525 N WATER STREET
KEOKUK, IA 52632
17025-19-04License Renewal Date:
Drawn By:
Drawing No.
Drawing Title
Structural Engineer t 312.440.2300 f 312.440.2303 www.baileyedward.com
35 East Wacker Dr Suite 2800 Chicago, IL 60601-2308
08-07-2020 FINAL DESIGN
Issue Date Title
PROPERTY OF THE UNITED STATES GOVERMENT
COPYING, DISSEMINATION, OR DISTRIBUTION OF
THESE DRAWINGS, PLANS, OR SPECIFICATIONS TO
UNAUTHORIZED USERS IS PROHIBITED.
Do not remove this notice.
Properly destroy documents when no longer needed.
GEI CONSULTANTS OF MICHIGAN, P.C.
109 W. BARAGA AVENUE
MARQUETTE, MI 49855
(906)451-4021
Consultants
Pr int
D ate
/T im e:
8/1
8/2
0 9 :55
A M
USGS CONTRACT NO.:
140G0220F0140
GENERAL
ELECTRICAL
NOTES
E-001
NPT
Chris Donaldson
Chris Donaldson
Chris Donaldson
Chris Donaldson ITEMS 15 AND 34. CABLE RUNS ADJUSTED TO BE RAN INSIDE OF CONDUIT WHERE POSSIBLE AND NOT ATTACHED TO HAND RAILS. THIS CHANGE WAS MADE TO ACCOMMODATE THE REMOVAL OF HAND RAILS
ITEM 19. CABLE RUNS ADJUSTED TO BE RAN INSIDE OF CONDUIT WHERE POSSIBLE AND NOT ATTACHED TO HAND RAILS. THIS CHANGE WAS MADE TO ACCOMMODATE THE REMOVAL OF HAND RAILS
SECTION B - B
E01
ERECTION NOTE:
AISC CODE OF STANDARD PRACTICE
AMERICAN INSTITUTE OF STEEL CONSTRUCTION
SECTION 7: PAGE 16.3-57: PARAGRAPH 7.14
7.14 CORRECTION OF ERRORS
NORMAL ERECTION OPERATIONS INCLUDE THE CORRECTION OF MINOR
MISFITS BY MODERATE AMOUNTS OF REAMING, CHIPPING, WELDING, OR
CUTTING, AND THE DRAWING OF ELEMENTS INTO LINE THROUGH THE USE OF
DRIFT PINS. ERRORS WHICH CANNOT BE CORRECTED BY THE FOREGOING
MEANS, OR WHICH REQUIRE MAJOR CHANGES IN MEMBER CONFIGURATION,
ARE REPORTED IMMEDIATELY TO THE OWNER AND FABRICATOR BY THE
ERECTOR, TO ENABLE WHOEVER IS RESPONSIBLE EITHER TO CORRECT THE
ERROR OR TO APPROVE THE MOST EFFICIENT AND ECONOMIC METHOD OF
CORRECTION TO BE USED BY OTHERS.
Location :
Detailer :
Checker:
Date :
Project :
Drawing No. :
Phase :
Date :
Client :
Project No :
W.O.# :SKV
KPR
KEOKUK, IA
JF Brennan
COE LOCK - 19
12/14/2020
12/14/2020
23849
E02
A
A ISSUED FOR APPROVALSKV12/14/2020
REVISION DATE REVISION DESCRIPTIONREV MARK BY
DETAIL 3
E01
DETAIL 2
E01
DETAIL 1
E01
SECTION F - F
E01
SECTION C - C
E01
SECTION G - G
E02
SECTION D - D
E01
SECTION A - A
E01
SECTION H - H
E02
SECTION J - J
E02
SECTION K - K
E02
SECTION L - L
E02
SECTION M - M
E02
SECTION N - N
E02
EM
BE
D M
EN
T
TY
P
CUT
C U
T
TY
P
OPENING
O
PE
N
IN
G
O.D
BAR2X134/
P102
PL12/ "X18
(HANGER TOP CLAMP)
HSS20X12X12/
CONCRETE LATERAL
34/ " PLATE
( 2 ) 1 14/ "Ø HOLES FOR
1 "Ø HIT RE-500 V3 EPOXY_ANC
TYP
P101
PL34/ "X18
(J-HANGER TOP)
HE0
HE0
2/
REF: A1/S-310 & E8/S-510
REF: A6/S-302 & E8/S-508
REF: A1/S-302 , E8/S-505 & A4/S-511
CLOUDED INFORMATIONS.
KINDLY CONFIRM ALL
APPROVER NOTE:-
REF: D1/S-302 & E8/S-507 REF: E8/S-503 & E8/S-504
REF: D6/S-302 & E8/S-509
REF: S-512
(TACK / FILLET)
KINDLY VERIFY WELD TYPE
APPROVER NOTE:-
12/ " BENT PLATE
4'-4
( 2 ) (1 38/ "x3 18/ ") SLOTS
FOR 1 14/ "Ø A325N BOLTS
TYP
HSS20X12X12/HSS20X12X12/
N E02
N E02
134/
312/1'-4558/
4/
4/
4 4
14/ " PLATE
HOLES IN HSS FOR 38/ " Ø BOLTS
DRILL & THREAD MATCHING
M100
TUBE9 58/ "X14/
(ADCP HOUSING)
M E02
M E02
934/ "Ø HOLE IN TUBE
12/ _HEAVY_HEX_NUT
WELDED TO TUBE (TYP)
PIPE3STD
(HOSE CLAMPS TO
SECURE HYDROPHONE)
P103
PL14/ "X11
(ACCESS COVER)
3916/ " Ø HOLES IN TUBEHSS20X12X12/
L E02
L E02
CONCRETE LATERAL
J E02
J E02
1" PLATE
12/ " COVER FASTENER FLANGE
58/ " END PLATE
B/W SPEAKER & METAL.
14/ " NEOPRENE SPACER
12/ "Ø TAPPING BOLTS (TYP)
P104
PL1"X21
(HDPE SPEAKER
HOUSING COVER)
118/
CONCRETE LATERAL
HSS20X12X12/
1_HEAVY_HEX_NUT
WELDED TO PLATE
PL38/ "X10
WELDED TO TUBE
HEAVY LIFT SWIVEL HOIST RING
CROSBY HR 1000 UNC
118/
1 78/ "Ø HOLE IN TUBE
1 58/ "Ø HOLE IN PLATE
12/ " PLATE
12/ " BENT PLATE
HSS20X12X12/
1' -4
1' -8
HSS20X12X12/
KE0
KE0
1" PLATE
118/
B/W SPEAKER & METAL.
14/ " NEOPRENE SPACER
P104
PL1"X21
(HDPE SPEAKER
HOUSING COVER)
12/ "Ø TAPPING BOLTS (TYP)
12/ " COVER FASTENER FLANGE
EPOXY TO STEEL TUBE
RUBBER FERRULES
34/ " I.D 78/ " O.D
ROUND TUBE
CONCRETE LATERAL J
E02
J E02
4/
HSS20X12X12/
12/ " PLATE (TYP)
CONCRETE LATERAL
34/ _HEAVY_HEX_NUT
(WELDED TO HSS TUBE)
G E02
G E02
118/
1'-614/
2' -8
1 4/
1'-058/558/
2/
412/
HSS20X12X12/
( 2 ) 1 34/ "Ø HOLES FOR
1 12/ "Ø A325N
( 2 ) 1 14/ "Ø HOLES FOR
1 "Ø HIT RE-500 V3 EPOXY_ANC
TYP
412/
1'-6 1'
-1
4/
1" PLATE
58/ " PLATE
HSS20X12X12/
58/ " PLATE
12/ " COVER FASTENER FLANGE
COVER PLATE
1" HDPE SPEAKER HOUSING
716/ "Ø
12/ "Ø TAPPING BOLTS (TYP)
EPOXY TO STEEL TUBE
RUBBER FERRULES
34/ " I.D 78/ " O.D
ROUND TUBE
B/W SPEAKER & METAL.
14/ " NEOPRENE SPACER
HSS20X12X12/
578/
1'-234/
3 4/
( 6 ) 58/ "Ø HOLES FOR
12/ "Ø A307 BOLTS
PIPE3STD
14/ " ACCESS COVER
(12/ "x2") SLOTS
EACH SIDE
1'-1
1'-4
714/ 714/
TUBE9 58/ "X14/
14/ " PLATE
958/
HSS20X12X12/
4/
2/
1' -2
12/ " BENT PLATE
1-14/ _HEAVY_HEX_NUT
WELDED TO TUBE (TYP)
1'-1014/
FLOW
FLOW
TEMPORARY
ERDC TRAILER
EXISTING
BOAT JIB
CRANE
TO REMAIN
4" CONDUIT TO BE
ROUTED ALONG THE
WALL.
STRAIN RELIEFS
(TYPICAL)
CONTROL STAND
NEW
8" CORE
DRILL
TIN BUILDING
P1F10
EXISTING
IN-GROUND
HANDHOLE
LLW SWITCHBOARD
& PLC RACK #1A
SEE
STRUCTURAL
DWG FOR
DETAIL.
SAW CUT SLAB &
PROVIDE METAL
PLATE COVER
OVER CABLES.
PROVIDE OPENING THRU PLATE
COVERING CABLES FOR CABLE
TO RISE UP ALONG STAIR WALL.
TO EXISTING LLW
SWITCHBOARD
& PLC RACK #1A
EXISTING
EMBEDDED
CONDUIT
EXISTING
IN-GROUND
HANDHOLE
NEMA-3R
WALL-MOUNTED
PULL BOX
EXISTING
EMBEDDED
(TYP)
LLW SWITCHBOARD
& PLC RACK #1A
END OF GALLERY
TIN BUILDING JOB
TRAILER
SEE ON LINE
DIAGRAM
EXISTING
BOAT JIB
CRANE
TO REMAIN
EXISTING
IN-GROUND
HANDHOLE
EXISTING
IN-GROUND
HANDHOLE
TO EXISTING LLW
SWITCHBOARD
& PLC RACK #1A
13 2 3
SHEET KEYNOTES
GENERAL SHEET NOTES
1. SEE SHEET E-001 POWER OPTION NOTES.
2. REFER TO TELEMETRY DRAWINGS FOR
ADDITIONAL POWER REQUIREMENTS.
1. DEMOLISH THE EXISTING LIGHTING PANEL AND THE EXISTING 10KVA 480V-120/240V 1-PHASE TRANSFORMER INCLUDING ALL ASSOCIATED CONDUIT AND WIRING FROM THE EXISTING DISCONNECT
SWITCH SERVING THE EXISTING TRANSFORMER. THE DISCONNECT SWITCH SHALL REMAIN.
2. REWIRE ALL OF THE FOUR EXISTING BRANCH CIRCUIT LOADS OF THE EXISTING "LTG PNL" INTENDED TO BE DEMOLISHED TO THE NEW PANELBOARD "A" (REFER TO KEYNOTE #3 BELOW). INTERCEPT AND EXTEND CONDUIT AND WIRING AS REQUIRED. PROVIDE NEW CIRCUIT BREAKERS AT THE NEW PANELBOARD "A" TO
MATCH THE RATING OF THE EXISTING CIRCUIT BREAKERS IN THE EXISTING "LTG PNL".
3. INSTALL NEW SURFACE MOUNTED 150A/2P, 20-1P BRANCH PANELBOARD. COORDINATE WITH USGS FOR THE EXACT LOCATION OF THE PANELBOARD IN CONSIDERATION OF WATER ELEVATION IN THE EVENT WATER RISES IN THE AREA. THIS PANELBOARD SHALL FEED THE LOADS AT THE JOB TRAILER AND
EXISTING LOADS OF THE EXISTING "LTG PNL" INTENDED TO BE DEMOLISHED.
4. INSTALL 125A/2P, 250V NON-FUSIBLE, NEMA-3R DISCONNECT SWITCH AS HIGH IN ELEVATION AS IS PRACTICAL TO KEEP IT OUT OF THE FLOOD PLAIN. THE DISCONNECT SWITCH SHALL BE INSTALLED WITH THE OPERATING HANDLE OF THE DISCONNECT SWITCH NOT TO EXCEED 6'-7" ABOVE THE FLOOR OR
WORKING PLATFORM.
5. PROVIDE MEANS FOR SPEAKER /SENSOR CABLES TO RUN OVERHEAD FROM LOCKWALL SURFACE MOUNT
CONDUIT TO ERDC TRAILER.
6. PROVIDE TWO (2) 4"PVC TO ROUTE THE SPEAKER CABLE ALONG THE LOCKWALL SURFACE TO THE ERDC
JOB TRAILER. ROUTING OF SPEAKER CABLE PROTECTION RACEWAY MUST BE APPROVED BY
GOVERNMENT. ROUTING SHALL PROVIDE PULLING-FITTING OR JUNCTION BOX MEANS AS NECESSARY TO
MEET NEC BEND RADIUS REQUIREMENTS.
7. PROVIDE STRAIN RELIEFS FOR SPEAKER CABLES FROM CORE DRILL HOLE. EACH STRAIN RELIEFS SHALL SUPPORT NO MORE THAN FIVE (5) CABLES. REFER TO STRUCTURAL DRAWINGS FOR DETAILS. NOTE THAT HAND-RAIL MAY NEED TO BE REMOVED DURING DRILLING, AND RE-INSTALLED BACK IN PLACE.
8. EXISTING EMBEDDED CONDUIT FEEDING THE STORAGE SHED AND JIB CRANE. NO WORK REQUIRED, OTHER THAN TO LOCATE CONDUITS AND AVOID DAMAGE TO THEM.
9. LOCATION OF LOWER LANDWALL 480V 3-PHASE SWITCHGEAR WHERE THE STORAGE SHED IS FED FROM.
PROVIDE LOCK-OUT TAG-OUT PROCEDURES WHEN PERFORMING POWER WORK IN THE STORAGE SHED.
10. PROVIDE #1-3C AWG + 1#6 GRD CONNECTED ON THE LOADS SIDE OF THE NEMA-3R DISCONNECT SWITCH AND WITH 125A, 2P3W PLUG AT THE OTHER END OF THE CABLE. PROVIDE 125A/2P3W RECEPTACLE TO MATCH THE 125A, 2P3W PLUG AT THE JOB TRAILER. THE 125A PLUG AND RECEPTACLE OUTLET SHALL BE SIMILAR TO LEVITON'S EN/IEC 60309 IP66/67 WATERTIGHT PLUG AND SURFACE MOUNTING SOCKET OUTLET
OR EATON'S 125A IEC 309 PIN & SLEEVE DEVICES "AH" SERIES PLUG AND RECEPTACLE.
POWER TO THE JOB TRAILER CAN BE EASILY DISCONNECTED FROM THE TIN BUILDING BY SIMPLY UNPLUGGING IT FROM THE 125A RECEPTACLE OUTLET OR SOCKET AND THE #1-3C CONDUCTORS CAN BE ROLLED AND SECURED. ALL OF THESE SHALL BE DONE WITHOUT THE NEED OF AN ELECTRICIAN EVERY
TIME THE JOB TRAILER NEEDS TO BE MOVED.
11. UTILIZE EXISTING 100A DISCONNECT SWITCH TO SERVE THE 37.5KVA, SINGLE PHASE, 240X480 - 120/240V
WALL-MOUNTED TRANSFORMER. PROVIDE WALL SUPPORT OR BRACKET FOR THE TRANSFORMER AS
REQUIRED. COORDINATE WITH USGS FOR THE EXACT LOCATION OF THE TRANSFORMER IN
CONSIDERATION OF WATER ELEVATION IN THE EVENT WATER RISES IN THE AREA.
12. THE JOB TRAILER SHALL BE EQUIPPED WITH A 125A/2P3W, 120/240V PANELBOARD "B" (DESIGN IS BASED ON MOBILE OFFICE INC, CONTACT PERSON: JORGE SKRYPAK - 708 636 5400) . THIS PANELBOARD SHALL FEED THE HVAC SYSTEM OF TRAILER, LIGHTINGS, REQUIRED RECEPTACLE OUTLETS. PROVIDE AT LEAST SIX (6) ADDITIONAL DEDICATED QUAD RECEPTACLE OUTLETS TO BE LOCATED AS PER USGS DIRECTION. THE JOB TRAILER SHALL BE CUSTOMIZED TO LOCATE ALL REQUIRED WIRING DEVICES. REFER TO PANEL SCHEDULE ON SHEET T-103. COORDINATE WORK WITH THE PROJECT MANAGER AND WITH USGS AS REQUIRED.
13. PROVIDE KWHR METER OR SUBMETERING TO MEASURE POWER CONSUMPTION OF THE JOB TRAILER.
COORDINATE WORK WITH THE PROJECT MANAGER AND WITH USGS AS REQUIRED.
BE Project No.
MISSISSIPPI RIVER BASIN
LOCK & DAM 19 - KEOKUK
GLRIAC ACOUSTIC STUDY
525 N WATER STREET
KEOKUK, IA 52632
17025-19-04License Renewal Date:
Drawn By:
Drawing No.
Drawing Title
Structural Engineer t 312.440.2300 f 312.440.2303 www.baileyedward.com
35 East Wacker Dr Suite 2800 Chicago, IL 60601-2308
08-07-2020 FINAL DESIGN
Issue Date Title
PROPERTY OF THE UNITED STATES GOVERMENT
COPYING, DISSEMINATION, OR DISTRIBUTION OF
THESE DRAWINGS, PLANS, OR SPECIFICATIONS TO
UNAUTHORIZED USERS IS PROHIBITED.
Do not remove this notice.
Properly destroy documents when no longer needed.
GEI CONSULTANTS OF MICHIGAN, P.C.
109 W. BARAGA AVENUE
MARQUETTE, MI 49855
(906)451-4021
Consultants
Pr int
D ate
/T im e:
8/2
0/2
0 1 1:3
2 A M
USGS CONTRACT NO.:
140G0220F0140
LOWER LANDWALL
POWER PLAN
E-101
NPT
3 PLAN - LOWER LANDWALL
0 4'SCALE : 1/8" = 1'-0" 8' 16'
2 ELEVATION - LOWER LANDWALL
0 4'SCALE : 1/8" = 1'-0" 8' 16'
TO ULW - SB
CABLE ROOM FLOOR
ELEV. 515.00
LOCK FLOOR
ELEV. 470.50
GALLERY FLOOR
ELEV. 496.75
BOTTOM LOCK
WALL ELEV.
456.50
GALLERY TOP
ELEV. 504.75
TOP OF LOCK WALL
ELEV. 525.75
1 ONE LINE DIAGRAM
NOT TO SCALE
AutoCAD SHX Text 48L
AutoCAD SHX Text 49L
AutoCAD SHX Text 50L
AutoCAD SHX Text 1.5
AutoCAD SHX Text 452.50
AutoCAD SHX Text 447.50
AutoCAD SHX Text 450.50
AutoCAD SHX Text 467.00
AutoCAD SHX Text
472.00 TOP CULVERT
AutoCAD SHX Text
457.50 BOT CULVERT
AutoCAD SHX Text
496.75 BOT GALLERY
AutoCAD SHX Text
504.74 TOP GALLERY
AutoCAD SHX Text 1.5
AutoCAD SHX Text F
AutoCAD SHX Text F
AutoCAD SHX Text F
AutoCAD SHX Text
10KVA
AutoCAD SHX Text
LTG PNL
AutoCAD SHX Text
37.5KVA
AutoCAD SHX Text
PNL "A"
AutoCAD SHX Text
USGS JOB TRAILER
AutoCAD SHX Text
TIN BUILDING
AutoCAD SHX Text 2#4 - 1 "C14"C
AutoCAD SHX Text
WALL-MOUNTED TRANSFORMER 37.5KVA, SINGLE PHASE, 240X480 - 120/240V
AutoCAD SHX Text
3#1AWG + 1#6 GRD - 1 "C12"C
AutoCAD SHX Text
EXISTING FEEDER FROM THE EXISTING SWITCHBOARD
AutoCAD SHX Text
3# AWG + 1#6 GRD 10AWG + 1#6 GRD - 1 "C12"C
AutoCAD SHX Text
PNL "B"
AutoCAD SHX Text
125A/2P, 250V, NON-FUSIBLE NEMA-3R DISCONNECT SWITCH
AutoCAD SHX Text
125A/2P3W, 120/240V, 30-1P BRANCHES PANELBOARD
AutoCAD SHX Text M
0'-6"
0'-5"
ELECTRICAL WIRING
LOCATION
0'-5"
0'-11 2"
BE Project No.
MISSISSIPPI RIVER BASIN
LOCK & DAM 19 - KEOKUK
GLRIAC ACOUSTIC STUDY
525 N WATER STREET
KEOKUK, IA 52632
17025-19-04License Renewal Date:
Drawn By:
Drawing No.
Drawing Title
Structural Engineer t 312.440.2300 f 312.440.2303 www.baileyedward.com
35 East Wacker Dr Suite 2800 Chicago, IL 60601-2308
08-07-2020 FINAL DESIGN
Issue Date Title
PROPERTY OF THE UNITED STATES GOVERMENT
COPYING, DISSEMINATION, OR DISTRIBUTION OF
THESE DRAWINGS, PLANS, OR SPECIFICATIONS TO
UNAUTHORIZED USERS IS PROHIBITED.
Do not remove this notice.
Properly destroy documents when no longer needed.
GEI CONSULTANTS OF MICHIGAN, P.C.
109 W. BARAGA AVENUE
MARQUETTE, MI 49855
(906)451-4021
Consultants
Pr int
D ate
/T im e:
8/6
/20
1:
P M
USGS CONTRACT NO.:
140G0220F0140
ELEVATION
CORE
DRILL
PLACEMENT
E-201
NPT
1 ELEVATION - CORE DRILL PLACEMENT
0 4'SCALE : 1/8" = 1'-0" 8' 16'
2 ENLARGED SECTION
SCALE : 3" = 1'-0"
3 ISOMETRIC VIEW
NOT TO SCALE
TRANSDUCER, TESTED IN
SHOP AND ONSITE PRIOR TO
INSTALLATION INTO WATER.
WATERTIGHT CONNECTION WITH
SEACON BULKHEAD CONNECTOR
CABLE
8" VERTICAL CORE HOLE TO
INTERCEPT 16" HORIZONTAL
CORE DRILL TO RUN CABLES
FROM TRANSDUCERS AND
HYDROPHONES.
SHEET KEYNOTES
1. CONTRACTOR SHALL LOCATE VERTICAL CORE/DRILL HOLE
POSITION TO INTERSECT CENTER OF 16-INCH HORIZONTAL
CORE/DRILL HOLE. 16-INCH HORIZONTAL CORE/DRILL HOLE
SHALL BE POSITIONED ON THE CENTER OF THE ACOUSTIC
BARRIER MAIN SUPPORT BEAM OPENING.
2. MAKE SURE TO AVOID EXISTING STORM SEWER.
LOCK & DAM 19 - KEOKUK
GLRIAC ACOUSTIC STUDY
525 N WATER STREET
KEOKUK, IA 52632
17025-19-04License Renewal Date:
Drawn By:
Drawing No.
Drawing Title
Structural Engineer t 312.440.2300 f 312.440.2303 www.baileyedward.com
35 East Wacker Dr Suite 2800 Chicago, IL 60601-2308
08-07-2020 FINAL DESIGN
Issue Date Title
PROPERTY OF THE UNITED STATES GOVERMENT
COPYING, DISSEMINATION, OR DISTRIBUTION OF
THESE DRAWINGS, PLANS, OR SPECIFICATIONS TO
UNAUTHORIZED USERS IS PROHIBITED.
Do not remove this notice.
Properly destroy documents when no longer needed.
GEI CONSULTANTS OF MICHIGAN, P.C.
109 W. BARAGA AVENUE
MARQUETTE, MI 49855
(906)451-4021
Consultants
Pr int
D ate
/T im e:
8/6
/20
1:
P M
USGS CONTRACT NO.:
140G0220F0140
SECTION
CORE
DRILL
E-301
NPT
AutoCAD SHX Text
SPEAKER/HYDROPHONE HOUSING
AutoCAD SHX Text
HYDROPHONE, SPEAKER CABLES (REFER TO SHEET E-201 FOR MORE INFORMATION)
AutoCAD SHX Text
TO OTHER SPEAKERS OR HYDROPHONES.
LOCK & DAM 19 - KEOKUK
GLRIAC ACOUSTIC STUDY
525 N WATER STREET
KEOKUK, IA 52632
17025-19-04License Renewal Date:
Drawn By:
Drawing No.
Drawing Title
Structural Engineer t 312.440.2300 f 312.440.2303 www.baileyedward.com
35 East Wacker Dr Suite 2800 Chicago, IL 60601-2308
08-07-2020 FINAL DESIGN
Issue Date Title
PROPERTY OF THE UNITED STATES GOVERMENT
COPYING, DISSEMINATION, OR DISTRIBUTION OF
THESE DRAWINGS, PLANS, OR SPECIFICATIONS TO
UNAUTHORIZED USERS IS PROHIBITED.
Do not remove this notice.
Properly destroy documents when no longer needed.
GEI CONSULTANTS OF MICHIGAN, P.C.
109 W. BARAGA AVENUE
MARQUETTE, MI 49855
(906)451-4021
Consultants
Pr int
D ate
/T im e:
8/6
/20
1:
P M
USGS CONTRACT NO.:
140G0220F0140
SECTION
CORE
DRILL
E-301
NPT
AutoCAD SHX Text
SPEAKER/HYDROPHONE HOUSING
AutoCAD SHX Text
HYDROPHONE, SPEAKER CABLES (REFER TO SHEET E-201 FOR MORE INFORMATION)
AutoCAD SHX Text
TO OTHER SPEAKERS OR HYDROPHONES.
weaton Cloud+ weaton
Provided by Brown Electric and installed by Brennan.
LOCK & DAM 19 - KEOKUK
GLRIAC ACOUSTIC STUDY
525 N WATER STREET
KEOKUK, IA 52632
17025-19-04License Renewal Date:
Drawn By:
Drawing No.
Drawing Title
Structural Engineer t 312.440.2300 f 312.440.2303 www.baileyedward.com
35 East Wacker Dr Suite 2800 Chicago, IL 60601-2308
08-07-2020 FINAL DESIGN
Issue Date Title
PROPERTY OF THE UNITED STATES GOVERMENT
COPYING, DISSEMINATION, OR DISTRIBUTION OF
THESE DRAWINGS, PLANS, OR SPECIFICATIONS TO
UNAUTHORIZED USERS IS PROHIBITED.
Do not remove this notice.
Properly destroy documents when no longer needed.
GEI CONSULTANTS OF MICHIGAN, P.C.
109 W. BARAGA AVENUE
MARQUETTE, MI 49855
(906)451-4021
Consultants
Pr int
D ate
/T im e:
8/5
/20
3:
P M
USGS CONTRACT NO.:
140G0220F0140
STRUCTURAL
GENERAL NOTES
S-001
RSJ
HSS SHAPES ASTM A500... Fy = 46 KSI
LOCK & DAM 19 - KEOKUK
GLRIAC ACOUSTIC STUDY
525 N WATER STREET
KEOKUK, IA 52632
17025-19-04License Renewal Date:
Drawn By:
Drawing No.
Drawing Title
Structural Engineer t 312.440.2300 f 312.440.2303 www.baileyedward.com
35 East Wacker Dr Suite 2800 Chicago, IL 60601-2308
08-07-2020 FINAL DESIGN
Issue Date Title
PROPERTY OF THE UNITED STATES GOVERMENT
COPYING, DISSEMINATION, OR DISTRIBUTION OF
THESE DRAWINGS, PLANS, OR SPECIFICATIONS TO
UNAUTHORIZED USERS IS PROHIBITED.
Do not remove this notice.
Properly destroy documents when no longer needed.
GEI CONSULTANTS OF MICHIGAN, P.C.
109 W. BARAGA AVENUE
MARQUETTE, MI 49855
(906)451-4021
Consultants
Pr int
D ate
/T im e:
8/1
8/2
0 8 :32
A M
USGS CONTRACT NO.:
140G0220F0140
PLAN
LOWER LOCK
EMPTYING SYSTEM
S-101
RSJ
BULKHEAD SLOT
HYDROPHONE LOCATION
AT BASE OF WALL,
SEE SHEET S-902
SECTION AT CORE HOLEA NO SCALE
VERTICAL SUPPORT OF CABLES IN CORE HOLE TO BE PROVIDED BY PULLING CABLES
SECURED TO EYE BOLTS BY EXISTING RAILING
SEE SHEET S-905
FOR CONDUIT
PROVIDE (3) 12" EYE BOLT
ANCHORS FOR
SECURING CABLES
CORE HOLE
LO
CK
W
AL
L F
AC
E
2"
TR
EN
CH
1 2" P
LA
TE
8" 1' - 6"
VERIFY
3"1" ±
R = 2"
2" DIAMOND PLATE COVER
OVER 2" x 6" CONDUIT TRENCH
AT LADDER WELL. SEE SHEET S-905
SEE SHEET S-905 FOR
BOTTOM LAID HYDROPHONE
CABLE DETAILS
STAIRS
WAL
L
2" DIAMOND PLATE
COVER OVER CONDUIT
TRENCH
2" x 6" TRENCH IN
CONCRETE FOR
CABLES, PROVIDE 45°
CORNERS
CORE HOLE
COVERED BY
DIAMOND PLATE
A S-
A S-
1' - 0" LAP
PAST STAIRS
HYDROPHONE
LOCK & DAM 19 - KEOKUK
GLRIAC ACOUSTIC STUDY
525 N WATER STREET
KEOKUK, IA 52632
17025-19-04License Renewal Date:
Drawn By:
Drawing No.
Drawing Title
Structural Engineer t 312.440.2300 f 312.440.2303 www.baileyedward.com
35 East Wacker Dr Suite 2800 Chicago, IL 60601-2308
08-07-2020 FINAL DESIGN
Issue Date Title
PROPERTY OF THE UNITED STATES GOVERMENT
COPYING, DISSEMINATION, OR DISTRIBUTION OF
THESE DRAWINGS, PLANS, OR SPECIFICATIONS TO
UNAUTHORIZED USERS IS PROHIBITED.
Do not remove this notice.
Properly destroy documents when no longer needed.
GEI CONSULTANTS OF MICHIGAN, P.C.
109 W. BARAGA AVENUE
MARQUETTE, MI 49855
(906)451-4021
Consultants
Pr int
D ate
/T im e:
8/1
8/2
0 8 :32
A M
USGS CONTRACT NO.:
140G0220F0140
PLAN
LOWER LOCK
EMPTYING SYSTEM
S-101
RSJ
BULKHEAD SLOT
HYDROPHONE LOCATION
AT BASE OF WALL,
SEE SHEET S-902
SECTION AT CORE HOLEA NO SCALE
VERTICAL SUPPORT OF CABLES IN CORE HOLE TO BE PROVIDED BY PULLING CABLES
SECURED TO EYE BOLTS BY EXISTING RAILING
SEE SHEET S-905
FOR CONDUIT
PROVIDE (3) 12" EYE BOLT
ANCHORS FOR
SECURING CABLES
CORE HOLE
LO
CK
W
AL
L F
AC
E
2"
TR
EN
CH
1 2" P
LA
TE
8" 1' - 6"
VERIFY
3"1" ±
R = 2"
2" DIAMOND PLATE COVER
OVER 2" x 6" CONDUIT TRENCH
AT LADDER WELL. SEE SHEET S-905
SEE SHEET S-905 FOR
BOTTOM LAID HYDROPHONE
CABLE DETAILS
STAIRS
WAL
L
2" DIAMOND PLATE
COVER OVER CONDUIT
TRENCH
2" x 6" TRENCH IN
CONCRETE FOR
CABLES, PROVIDE 45°
CORNERS
CORE HOLE
COVERED BY
DIAMOND PLATE
A S-
A S-
1' - 0" LAP
PAST STAIRS
HYDROPHONE
weaton Dimension 17.5" weaton Line
LOCK & DAM 19 - KEOKUK
GLRIAC ACOUSTIC STUDY
525 N WATER STREET
KEOKUK, IA 52632
17025-19-04License Renewal Date:
Drawn By:
Drawing No.
Drawing Title
Structural Engineer t 312.440.2300 f 312.440.2303 www.baileyedward.com
35 East Wacker Dr Suite 2800 Chicago, IL 60601-2308
08-07-2020 FINAL DESIGN
Issue Date Title
PROPERTY OF THE UNITED STATES GOVERMENT
COPYING, DISSEMINATION, OR DISTRIBUTION OF
THESE DRAWINGS, PLANS, OR SPECIFICATIONS TO
UNAUTHORIZED USERS IS PROHIBITED.
Do not remove this notice.
Properly destroy documents when no longer needed.
GEI CONSULTANTS OF MICHIGAN, P.C.
109 W. BARAGA AVENUE
MARQUETTE, MI 49855
(906)451-4021
Consultants
Pr int
D ate
/T im e:
8/6
/20
7:
P M
USGS CONTRACT NO.:
140G0220F0140
SECTION
LANDSIDE LOWER
GUIDEWALL
S-301
RSJ
LIGHT
34' LONG, 8" DIA. CORE HOLE
IN CONCRETE LOCK WALL
HYDROPHONE
CONDUIT
BOTTOM LAID HYDROPHONE
CABLES RUN UP THIS LADDER WELL
SEE SHEET S-905
FOR CONDUIT
1' - 6" 2"
SAWCUT
EXTEND 12" PAST END OF STAIRS
SAW CUT CONDUIT TRENCH WITH
2" COVER PLATE
(3) 12" EYE BOLTS
ANCHORED IN TOP
OF CONCRETE
3" FROM GUARDRAIL
STAIRS
NOTE: 2" X 6" TRENCHES TO HAVE 45° CORNERS AND DIAMOND PLATE COVERS TO BE CUT (BEVELED) TO FIT AT CORNERS AND FASTENED WITH STAINLESS STEEL FASTENERS PER DETAIL A, S-905.
Chris Donaldson
Chris Donaldson
Chris Donaldson
DELETE SECTION OF TRENCH
Chris Donaldson Polygon
Chris Donaldson
ADD SECTION OF TRENCH
LOCK & DAM 19 - KEOKUK
GLRIAC ACOUSTIC STUDY
525 N WATER STREET
KEOKUK, IA 52632
17025-19-04License Renewal Date:
Drawn By:
Drawing No.
Drawing Title
Structural Engineer t 312.440.2300 f 312.440.2303 www.baileyedward.com
35 East Wacker Dr Suite 2800 Chicago, IL 60601-2308
08-07-2020 FINAL DESIGN
Issue Date Title
PROPERTY OF THE UNITED STATES GOVERMENT
COPYING, DISSEMINATION, OR DISTRIBUTION OF
THESE DRAWINGS, PLANS, OR SPECIFICATIONS TO
UNAUTHORIZED USERS IS PROHIBITED.
Do not remove this notice.
Properly destroy documents when no longer needed.
GEI CONSULTANTS OF MICHIGAN, P.C.
109 W. BARAGA AVENUE
MARQUETTE, MI 49855
(906)451-4021
Consultants
Pr int
D ate
/T im e:
8/5
/20
3:
P M
USGS CONTRACT NO.:
140G0220F0140
SECTIONS
S-302
RSJ
WIRING ACCESS COVER AT END
SEE SHT. S-507
CENTER SPLICE
SEE SHT. S-509
ADCP HOUSING
SEE SHT. S-508
SPEAKER HOUSING
SEE SHT. S-505 & S-506
LOCK & DAM 19 - KEOKUK
GLRIAC ACOUSTIC STUDY
525 N WATER STREET
KEOKUK, IA 52632
17025-19-04License Renewal Date:
Drawn By:
Drawing No.
Drawing Title
Structural Engineer t 312.440.2300 f 312.440.2303 www.baileyedward.com
35 East Wacker Dr Suite 2800 Chicago, IL 60601-2308
08-07-2020 FINAL DESIGN
Issue Date Title
PROPERTY OF THE UNITED STATES GOVERMENT
COPYING, DISSEMINATION, OR DISTRIBUTION OF
THESE DRAWINGS, PLANS, OR SPECIFICATIONS TO
UNAUTHORIZED USERS IS PROHIBITED.
Do not remove this notice.
Properly destroy documents when no longer needed.
GEI CONSULTANTS OF MICHIGAN, P.C.
109 W. BARAGA AVENUE
MARQUETTE, MI 49855
(906)451-4021
Consultants
Pr int
D ate
/T im e:
8/5
/20
3:
P M
USGS CONTRACT NO.:
140G0220F0140
SECTIONS
PICK POINT
CONNECTION
S-310
LIFTING RINGS
LOCK & DAM 19 - KEOKUK
GLRIAC ACOUSTIC STUDY
525 N WATER STREET
KEOKUK, IA 52632
17025-19-04License Renewal Date:
Drawn By:
Drawing No.
Drawing Title
Structural Engineer t 312.440.2300 f 312.440.2303 www.baileyedward.com
35 East Wacker Dr Suite 2800 Chicago, IL 60601-2308
08-07-2020 FINAL DESIGN
Issue Date Title
PROPERTY OF THE UNITED STATES GOVERMENT
COPYING, DISSEMINATION, OR DISTRIBUTION OF
THESE DRAWINGS, PLANS, OR SPECIFICATIONS TO
UNAUTHORIZED USERS IS PROHIBITED.
Do not remove this notice.
Properly destroy documents when no longer needed.
GEI CONSULTANTS OF MICHIGAN, P.C.
109 W. BARAGA AVENUE
MARQUETTE, MI 49855
(906)451-4021
Consultants
Pr int
D ate
/T im e:
8/5
/20
3:
P M
USGS CONTRACT NO.:
140G0220F0140
DETAILS
S-501
RSJ
END OF WELDMENT, LANDSLIDE
8" DIA. CORE HOLE FROM TOP
8" DIA. CORE HOLE FROM TOP
NOTE 1
16" DIA. CORE HOLE WELDMENT
LOCK & DAM 19 - KEOKUK
GLRIAC ACOUSTIC STUDY
525 N WATER STREET
KEOKUK, IA 52632
17025-19-04License Renewal Date:
Drawn By:
Drawing No.
Drawing Title
Structural Engineer t 312.440.2300 f 312.440.2303 www.baileyedward.com
35 East Wacker Dr Suite 2800 Chicago, IL 60601-2308
08-07-2020 FINAL DESIGN
Issue Date Title
PROPERTY OF THE UNITED STATES GOVERMENT
COPYING, DISSEMINATION, OR DISTRIBUTION OF
THESE DRAWINGS, PLANS, OR SPECIFICATIONS TO
UNAUTHORIZED USERS IS PROHIBITED.
Do not remove this notice.
Properly destroy documents when no longer needed.
GEI CONSULTANTS OF MICHIGAN, P.C.
109 W. BARAGA AVENUE
MARQUETTE, MI 49855
(906)451-4021
Consultants
Pr int
D ate
/T im e:
8/5
/20
3:
P M
USGS CONTRACT NO.:
140G0220F0140
DETAILS
S-501
RSJ
END OF WELDMENT, LANDSLIDE
8" DIA. CORE HOLE FROM TOP
8" DIA. CORE HOLE FROM TOP
NOTE 1
16" DIA. CORE HOLE WELDMENT
weaton Dimension 32" weaton Dimension 21.5" weaton Line weaton Callout Red Head A7+ Epoxy
LOCK & DAM 19 - KEOKUK
GLRIAC ACOUSTIC STUDY
525 N WATER STREET
KEOKUK, IA 52632
17025-19-04License Renewal Date:
Drawn By:
Drawing No.
Drawing Title
Structural Engineer t 312.440.2300 f 312.440.2303 www.baileyedward.com
35 East Wacker Dr Suite 2800 Chicago, IL 60601-2308
08-07-2020 FINAL DESIGN
Issue Date Title
PROPERTY OF THE UNITED STATES GOVERMENT
COPYING, DISSEMINATION, OR DISTRIBUTION OF
THESE DRAWINGS, PLANS, OR SPECIFICATIONS TO
UNAUTHORIZED USERS IS PROHIBITED.
Do not remove this notice.
Properly destroy documents when no longer needed.
GEI CONSULTANTS OF MICHIGAN, P.C.
109 W. BARAGA AVENUE
MARQUETTE, MI 49855
(906)451-4021
Consultants
Pr int
D ate
/T im e:
8/1
8/2
0 8 :27
A M
USGS CONTRACT NO.:
140G0220F0140
DETAILS
S-502
RSJ
3" DIA. PIPE WITH SLOTS
FOR HOSE CLAMPS TO
SECURE HYDROPHONE,
SEE SHEET S-512 SECTION A
6' - 6"
Chris Donaldson PICK POINT EYE BOLTS REMOVED AND REPLACED WITH CUSTOM HEX HEAD BOLT. EYE BOLTS TO BE RETAINED BY USGS FOR DECOMMISSION
MARINE GREASE ADDED TO BOLTS FOR CORROSION RESISTANCE
CONDUIT WAS SECURED THROUGH ONLY ONE SIDE AND REQUIRED THE ADDITION OF TWO BOLTS FOR STRUCTURAL STRENGTH. ADDITIONAL BOLTS WERE ADDED AT EACH SPLICE POINT ON THE TUBE
Chris Donaldson 3/4 INCH BY 3 INCH PLATE ADDED AT FOUR POINTS FOR STRUCTURAL STRENGTH. THIS WAS PERFORMED ON THE RIVER SIDE ONLY
Chris Donaldson Pencil
Chris Donaldson UPON INSPECTION HOLE WAS THROUGH BOTH SIDES. HOLE COVERED UTILIZING A PLATE AND BOLTS
Chris Donaldson
Chris Donaldson
Chris Donaldson
Chris Donaldson
Chris Donaldson
Chris Donaldson
Chris Donaldson
Chris Donaldson
Chris Donaldson
Chris Donaldson
Pencil
LOCK & DAM 19 - KEOKUK
GLRIAC ACOUSTIC STUDY
525 N WATER STREET
KEOKUK, IA 52632
17025-19-04License Renewal Date:
Drawn By:
Drawing No.
Drawing Title
Structural Engineer t 312.440.2300 f 312.440.2303 www.baileyedward.com
35 East Wacker Dr Suite 2800 Chicago, IL 60601-2308
08-07-2020 FINAL DESIGN
Issue Date Title
PROPERTY OF THE UNITED STATES GOVERMENT
COPYING, DISSEMINATION, OR DISTRIBUTION OF
THESE DRAWINGS, PLANS, OR SPECIFICATIONS TO
UNAUTHORIZED USERS IS PROHIBITED.
Do not remove this notice.
Properly destroy documents when no longer needed.
GEI CONSULTANTS OF MICHIGAN, P.C.
109 W. BARAGA AVENUE
MARQUETTE, MI…