Product Data Sheet

7490 (478JB)

Aliphatic Urethane

Issued: February 2019 Page: 1/2

Description: 7490 (Hempel 478JB) is a single-component, aliphatic polyurethane coating.

Recommended use: As a weather-protective topcoat for polyurethane foam, concrete, metal, single-ply and built-up/modified bitumen roof systems.

Certificates/approvals: LEED: MRc5, SSc7.2

CRRC: 0720-0005

Miami-Dade: NOA No.: 16-0222.02, NOA No.: 16-0322.27

Availability: Available in North America. Not included in Group Assortment; other regions must confirm.

Colors and packaging:

7490 (478JB10000) White 5- and 55-gallon

Physical constants:

Tensile Strength Elongation Permanent Set Tear Resistance Water Resistance Taber Abrasion Shore A Adhesion to 70630

Weight/Gallon Weight Solids Volume Solids

VOC

Flash Point Shelf Life

3,042 psi 263% 80% 400 pli 2.2% @ 7 days 20 mg/1,000 rev cs17

10.7 lbs/in

11.4 lbs/gal 82% 74% 247 g/L 85°F (29°C) 1 year

ASTM D412

ASTM D412

ASTM D412

ASTM D1004

ASTM D471

ASTM D4060

ASTM D2240

ASTM D903

ASTM D1475

ASTM D4209

Calculated EPA Method 24

ASTM D3278

The above tested results are typical values. Individual lots may vary up to 10% from the typical value. Further technical information can be found at www.neogard.com.

Application details:

Application method:

Thinner (max.vol.):

Mixing:

Pot life:

Cleaning of tools:

Roller or spray (contact NEOGARD® for spray equipment information) 7055 Odorless Reducer (086JB1L001) or HEMPEL'S THINNER 08080 (xylene) (10%) Mix for a minimum of 3–5 minutes before applying 6–8 hours hours/minutes at 75°F (23°C) 7055 Odorless Reducer (086JB1L001) or HEMPEL'S THINNER 08080 (xylene)

Safety: Handle with care. Use with adequate ventilation. Before and during use, observe all safety labels on packaging and paint containers, consult NEOGARD® Safety Data Sheets and follow all local or national safety regulations.

Application conditions: Substrate temperature must be above 40°F (5°C) and/or below 100°F (37°C), and more than 5°F (3°C) above the dewpoint and rising.

Preceding coat: According to NEOGARD® Guide Specifications.

Accelerators and additives: 7931 (9905500000): Standard cure accelerator.

7986 (994JB00000): Masks offensive odors; vanilla-scented.

7987 (995JB00000): Masks offensive odors; orange-scented.

Storage temperature: Store in a cool area to ensure full shelf life. Recommended temperature: 75°F (23°C).

7490 (478JB)

Aliphatic Urethane

Issued: February 2019 Page: 2/2

Remarks: Product is sensitive to moisture; not recommended for constant immersion. Concrete must have a full 28 day cure period prior to coating. Not compatible with asphaltic compounds. Not for use with insulating concrete such as Zonolite, Vermiculite, Perlite, etc. Not for use over aluminized coated roofs.

Note: 7490 (478JB) is for professional use only.

Issued by: Hempel A/S – 478JB

This Product Data Sheet supersedes those previously issued.

Manufacturer warrants that the physical properties of the product reported above will meet the standards and deviations of the associated ASTM test method.

MANUFACTURER HEREBY EXPRESSLY DISCLAIMS ANY AND ALL OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING, WITHOUT LIMITATION, ANY IMPLIED WARRANTY OF MERCHANTABILITY AND/OR IMPLIED WARRANTY OF FITNESS FOR A PARTICULAR PURPOSE. Buyer must make its own determination of the suitability of any product for its use, whether such product is used alone or in combination with other materials. To the extent this or any of Manufacturer’s products is proven to be defective, Buyer’s sole remedy shall be limited to the replacement of such defective product, exclusive of any costs of labor. MANUFACTURER SHALL NOT BE LIABLE OR OBLIGATED FOR ANY LOSS OR CONSEQUENTIAL OR OTHER DAMAGE INCURRED DIRECTLY OR INDIRECTLY BY BUYER OR ANY OTHER PERSON OR ENTITY THAT ARISES IN ANY WAY IN RELATION TO THIS OR ANY OF MANUFACTURER’S OTHER PRODUCTS. Nothing contained herein shall be construed to constitute inducement or recommendation to practice any invention covered by any patent without authority of the owner of the patent. No Applicator is or should be viewed as an employee or agent of Manufacturer. 7490-PDS ksk 02202019.docx

NEOGARD®, a Division of Hempel (USA), Inc.

2728 Empire Central - Dallas, Texas 75235 - Phone (214) 353-1600 - Fax (214) 357-7532 - www.neogard.com

Made in the USA gaco.com 800.331.0196

Product Data Sheet: GacoRoofFoam™ 2733

August 2015 Supersedes 12/14

GacoRoof Foam™ SYSTEM 2733

DESCRIPTION:

GacoRoofFoam F2733 is an HFC blown (zero-ozone depleting) liquid spray system that cures to a medium-density rigid polyurethane insulation for roofing applications. GacoRoofFoam 2733 does not contain CFCs, HCFCs or other gases harmful to the ozone layer.

TECHNICAL INFORMATION:

GacoRoofFoam 2733 meets ASTM E108 Class A rating for external fire exposure. This system has UL and FM 4470 approvals and exceeds the requirements of ASTM C1029 (Type III).

APPLIED PRODUCT DATA:

Property Test Temp. ASTM Test Value* Unit

Nominal Density:

Sprayed-in-Place

77°F (25°C) D1622 2.7 - 3.4 lbs/ft

Aged R-Value C518 R-6.5 at 1”

R-25 at 3.5” h·ft ·°F/Btu h·ft ·°F/Btu

Compressive Strength:

Parallel to Rise

77°F (25°C) D1621 53.7 psi

Tensile Strength 77°F (25°C) D1623 60.2 psi

Sheer C273 44.1 psi

Water Vapor Transmission

77°F (25°C)

E96 Desiccant Method

0.98 perm-in

Dimensional Stability (28 Day) 158°F (70°C), 97% RH D2126

Width 0.01

Length 0.00

Depth 0.00

% linear change

Water Absorption D2842 0.5 Pass %

Closed Cell Content 77°F (25°C) D2856C 98.2 %

Spread of Flame E84

UL723

Flame Spread Index

Recommended Service Temperature Range

-40°F (-4.4°C) to

200°F (93°C) http://www.gaco.com/

GacoRoofFoam

TM

Made in the USA gaco.com 800.331.0196

To ensure optimum performance, a minimum pass thickness of 3/4” (1.90 cm) is recommended with the maximum not to exceed 1.5” (4 cm) per pass. It is recommended that the resin side pre-heater be set 10-15°F warmer than the Isocyanate side to equalize component viscosities. Maximum spray equipment temperature setting is 130°F (54°C).

This system can be sprayed on clean dry substrates down to 45°F (7°C). GacoRoofFoam 2733 must not be applied if the temperature during application is less than 5 degrees above the dew point.

For additional information, please consult Gaco Western’s GW 6-2 GacoRoofFoam Spray Guide.

TYPICAL LIQUID CHEMICAL PROPERTIES

"A" Component contains polymeric isocyanate.

"B" Component contains polyol, catalysts and blowing agents.

Property

Test Temp. ASTM Test Value Unit

Viscosity

77°F (25°C) D2196 “A” Component: 200 ± 50 “B” Component: 1150 ± 50 cps

Specific Gravity

77°F (25°C) D1638 “A” Component: 1.23 “B” Component: 1.17

S.G.

Weight/Gallon

77°F (25°C) “A” Component: 10.2 “B” Component: 9.8 lbs/gal

Mixing Ratio

“A” & “B” Component: 1:1 by volume

Stability when stored at 50°F to 70°F (10°C to 21°C)

“A” Component: 12 “B” Component: 3 months

NOTE: All hot work, i.e. welding, torches and open flame work must be completed prior to installation of the polyurethane foam insulation. Smoking in the same area while the spray polyurethane foam insulation is being applied shall be strictly prohibited.

Recommendations and safety considerations for application are outlined in Gaco Western’s Spray Guide SG-GacoRoofFoam. The aforementioned information on this product is to be used as a guide and is subject to change without notice. These suggestions and data are based on information we believe to be reliable. They are offered in good faith, but without guarantee, as conditions and methods and use of our products are beyond our control. Any obligation of the seller or manufacturer shall have no force or effect unless it is in writing and signed by officers of the manufacturer.

The information herein is believed to be reliable but unknown risks may be present. ALL WARRANTIES OF ANY KIND, EXPRESSED OR IMPLIED, INCLUDING WARRANTIES OF FITNESS FOR A PARTICULAR PURPOSE AND THAT GOODS ARE OF MERCHANTABLE QUALITY, ARE SPECIFICALLY DISCLAIMED. See Gaco Western for information concerning its limited warranty and its availability.

For specific Safety and Health information please refer to Safety Data Sheet.

http://www.gaco.com/

70620 Aromatic Urethane Roofing Base Coat

PRODUCT DESCRIPTION

70620 is a single-component, moisture-cured, fire retardant, aromatic polyurethane base coat for polyurethane foam, concrete and single-ply roof systems.

SYSTEM DESIGN

This product is a base coat component of NEOGARD® Permathane, Elasta-Gard C and Elasta-Gard SP fluid-applied roof coating systems covered more thoroughly in NEOGARD® Guide Specifications and System Summaries.

USES

• Polyurethane foam roofs

• Structural concrete roof decks and canopies

• Existing single ply roofs

LIMITATIONS

• Use with adequate ventilation

• Not intended for use as a topcoat; product is not UV-resistant

• Not intended for ponding water or constant immersion

• Concrete must have a full 28 day cure period prior to coating

• Not compatible with asphaltic compounds

• Not for use with insulating concrete such as Zonolite, Vermiculite, Perlite, etc.

• Substrate temperature must be above 40°F (5°C) and/or below 100°F (37°C), and more than 5°F (3°C) above the dewpoint and rising

• Substrate must be clean, dry, sound and secure

• Product is moisture-sensitive

PRODUCT COLORS AND PACKAGING

Product Number Color Packaging 70620 Dark Gray 55- and 5-gallon

APPLICATION INSTRUCTIONS

NEOGARD® products are to be installed in accordance with instructions in the NEOGARD® Fluid-Applied Roof Coating Systems Application Manual.

MIXING AND THINNING

Read product labels and application instructions prior to use. Product must be mixed. Read container labels, Safety Data Sheets (SDS) and application instructions prior to mixing. Mix polyurethane material with a variable speed drill utilizing a Jiffy Mixer to suspend any settled pigment and attain a uniform color. Introduce approved optional Additives after material is thoroughly mixed and continue mixing.

This product has been formulated to be applied without the need of thinning. However, application under certain conditions and with certain equipment may be enhanced by thinning. Please note that thinning will increase VOC content of the mixed coating. Always know local VOC restrictions for coating applications in your area before thinning this product. Do not thin material more than 10%. See compatible thinners and additional mixing instructions in the NEOGARD® Application Manual or contact NEOGARD® Technical Service at techservice@ neogard.com.

CURED PROPERTIES

Description Test Method Results Tensile Strength ASTM D412 643 psi

Elongation ASTM D412 620%

Permanent Set ASTM D412 5%

Tear Resistance ASTM D1004 2.205 (lbs-force)

Water Resistance ASTM D471 <3% @ 7 days

Shore A Hardness ASTM D2240 65–71

Adhesion to Foam ASTM D903 18.24 lbs/in

Recoat Time @ 75°F (23°C), 50% RH (25 mils WFT)

Calculated 5 hours

The above tested results are typical values. Individual lots may vary up to 10% from the typical value. Note: Further technical information can be found at http:// www.neogard.com.

PRODUCT DATA

Description Test Method Results Weight/Gallon ASTM D1475 10.38 lbs/gal

Weight Solids ASTM D2369 81%

Volume Solids Calculated 77%

VOC ASTM D3960 205 g/L

Flash Point ASTM D56 127°F

Shelf Life 1 year The above tested results are typical values. Individual lots may vary up to 10% from the typical value. Note: Further technical information can be found at http:// www.neogard.com.

ADDITIVES

Product No. Description Use

7931 Fast Accelerator Low-humidity fast accelerator for 70620 Series urethane

7922 Vertical Additive Enhances sag-resistant properties

Manufacturer warrants that the physical properties of the product reported above will meet the standards and deviations of the associated ASTM test method. MANUFACTURER HEREBY EXPRESSLY DISCLAIMS ANY AND ALL OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING, WITHOUT LIMITATION, ANY IMPLIED WARRANTY OF MERCHANTABILITY AND/OR IMPLIED WARRANTY OF FITNESS FOR A PARTICULAR PURPOSE. Buyer must make its own determination of the suitability of any product for its use, whether such product is used alone or in combination with other materials. To the extent this or any of Manufacturer’s products is proven to be defective, Buyer’s sole remedy shall be limited to the replacement of such defective product, exclusive of any costs of labor. MANUFACTURER SHALL NOT BE LIABLE OR OBLIGATED FOR ANY LOSS OR CONSEQUENTIAL OR OTHER DAMAGE INCURRED DIRECTLY OR INDIRECTLY BY BUYER OR ANY OTHER PERSON OR ENTITY THAT ARISES IN ANY WAY IN RELATION TO THIS OR ANY OF MANUFACTURER’S OTHER PRODUCTS. Nothing contained herein shall be construed to constitute inducement or recommendation to practice any invention covered by any patent without authority of the owner of the patent. No Applicator is or should be viewed as an employee or agent of Manufacturer. 70620-PDS ksk 06152016.indd

NEOGARD®, a Division of Hempel (USA), Inc.

2728 Empire Central - Dallas, Texas 75235 - Phone (214) 353-1600 - Fax (214) 357-7532 - www.neogard.com

Product No. Description Use

7986 Odor Mask Masks offensive odors; vanilla-scented

7987 Odor Mask Masks offensive odors; orange-scented

STORAGE AND HANDLING

Containers of urethane coating should be stored in a cool (75°F, 23°C) area to ensure full shelf life. Keep container closed. Keep away from sources of ignition. To prevent container rupture due to very high temperature, keep away from heat and/or open flames.

CLEAN UP

Clean tools and equipment with aromatic solvents such as Xylene, Toluene, MEK or 7055 Odorless Reducer.

HEALTH AND SAFETY

Read the SDS and container labels for detailed health and safety information. This product is intended for industrial use by properly trained professional applicators only.

CREDENTIALS

07 57 00-001 Coated Foam Roofing_18018_BE Review
Stratified Transmittal 07 57 00-001 Coated Foam Roofing

File details come from the government source that posted it. Updated .