B08__Attachment_1_Eufaula_pipe_drawings___specs_0002.pdf
PDF 1 MB Posted
- Attached to
- Drainage Pipe Eufaula National Wildlife Refuge
- Solicitation number
- 140F0S24Q0048
About this file
This document appears to be a set of drawings and specifications for a 48-inch steel reinforced polyethylene (SRPE) drainage pipe system for the U.S. Fish and Wildlife Service's Eufaula National Wildlife Refuge in Eufaula, Alabama. The drawings provide details on the pipe configuration, including a manifold tee with a diverter wedge, as well as installation and construction loading requirements. The related federal contract opportunity is a combined synopsis/solicitation (Solicitation No. 140F0S24Q0048) for the procurement of 600 feet of 48-inch SRPE pipe with flanged adapters and a 45-degree wye. The government intends to award a firm-fixed-price contract with a delivery date estimate of October 31, 2024. The solicitation is set aside for small businesses under NAICS code 331210, with a size standard of 1,000 employees. Key dates include a question submission deadline of August 9, 2024, and a quote submission deadline of August 13, 2024.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| Sol_140F0S24Q0048_Amd_0002.pdf | ||
| Sol_140F0S24Q0048_Amd_0001.pdf | ||
| B08_140F0S24Q0048.pdf | ||
| Sol_140F0S24Q0048.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
24'-0"
A
24'-0"
X
24'-0"
X
24'-0"
X
24'-0"
X
24'-0"
X
24'-0"
X
24'-0"
X
24'-0"
X
24'-0"
X
24'-0"
X
24'-0"
X
24'-0"
X
CONNECT TO FIELD RISER
STUB W/ FLANGED ADAPTER
W/ BACKING RING
528'-5"
0+
0+
0+
0+
0+
1+
1+
1+
1+
1+
2+
2+
2+
2+
2+
3+
24'-0"
X
24'-0"
X
24'-0"
X
24'-0"
X
24'-0"
X
24'-0"
X
24'-0"
X
24'-0"
X
24'-0"
X
'-0
X
24'-0" X
528'-5"
24'-0"
45°
45°
24'-0"
6'-4"
INTERNAL DIVERTING WALL
PLATE WEDGE (1" THICK
HDPE PLATE W/ INTERNAL
GUSSETS)
3+
3+
3+
3+
4+
4+
4+
4+
4+
5+
5+
MANIFOLD TO BE ENCASED IN STABILIZED FILL
B
JAP
CHECKED:
DRAWN:DESIGNED:
APPROVED:
I:\ M
ER
LI
N \P
R O
JE
C
T\
AC
TI
VE
\8
0\
\8
4-
0- D
M
AX
X- C
O N
-A .D
W G
/2
/2
9:
A
M
SHEET NO.:
OF 5
7/2/2024 DATE:PROJECT No.:
808414 SEQ. No.:
808414-010-DMAXX-CON-A
1REVISION DESCRIPTIONDATEMARK BY
- 808414-010
AL FISH & WILDLIFE
EUFAULA, AL
SITE DESIGNATION: 48IN OUTFALL
The design and information shown on this drawing is provided as a service to the project owner, engineer and contractor by Contech Engineered Solutions LLC ("Contech"). Neither this drawing, nor any part thereof, may be used, reproduced or modified in any manner without the prior written consent of Contech. Failure to comply is done at the user's own risk and Contech expressly disclaims any liability or responsibility for such use.
If discrepancies between the supplied information upon which the drawing is based and actual field conditions are encountered as site work progresses, these discrepancies must be reported to Contech immediately for re-evaluation of the design. Contech accepts no liability for designs based on missing, incomplete or inaccurate information supplied by others.
FULL SIZE 24"X36" SHEETS
NOTES
· ALL RISER AND STUB DIMENSIONS ARE TO CENTERLINE.
· ALL ELEVATIONS, DIMENSIONS, AND LOCATIONS OF
RISERS AND INLETS, SHALL BE VERIFIED BY THE
ENGINEER OF RECORD PRIOR TO RELEASING FOR
FABRICATION.
· ALL RISERS AND STUBS ARE FABRICATED USING HDPE
DR32.5 & M294 PIPE UNLESS OTHERWISE NOTED.
· RISERS TO BE FIELD TRIMMED TO GRADE.
· QUANTITY OF PIPE SHOWN DOES NOT PROVIDE EXTRA
PIPE FOR CONNECTING THE SYSTEM TO EXISTING PIPE
OR DRAINAGE STRUCTURES. OUR SYSTEM AS DETAILED
PROVIDES NOMINAL INLET AND/OR OUTLET PIPE STUB FOR
CONNECTION TO EXISTING DRAINAGE FACILITIES. IF
ADDITIONAL PIPE IS NEEDED IT WILL HAVE TO BE
REQUESTED BY THE REVIEWER/APPROVAL AUTHORITY
PRIOR TO FABRICATION.CUSTOMER DATE
THE UNDERSIGNED HEREBY APPROVES THE ATTACHED (5) PAGES
INCLUDING THE FOLLOWING:
· WALL TYPE = NON-PERFORATED
· DIAMETER = XXX
· PIPE MATERIAL = SRPE
· JOINT TYPE = QUIKJOINT BELL & SPIGOT
· LOADING = HS-20
· DESIGN IS BASED ON THE ASSUMPTION THAT THE MAX
INTERNAL PRESSURE IS 10.8PSI (25FT OF HEAD) OR LESS
STATION: 0+00 TO 3+11
SCALE: 1"=10'
STATION: 3+11 TO 5+28.44
SCALE: 1"=10'
M
ATC
H
LIN
E A
M
AT
C H
LI
N
E A
SYSTEM BoM
FITTING TYPE QTY Ø MATERIAL WALL
TYPE LENGTH TOTAL
A PIPE 1 48 DUROMAXX SOLID 24.00 24.00
A1 FLANGED ADAPTER 1 48 DR32.5 SOLID 0.00 0.00
A1-1 BACKING RING 1 48 CAST IRON SOLID
B MANIFOLD TEE/WYE 1 48 DUROMAXX SOLID 12.00 12.00
B1 TEE STUB 1 48 DUROMAXX SOLID 4.25 4.25
B2 DIVERTER WEDGE 1 1" THICK HDPE SOLID
B3 DIVERTER WEDGE 1 1" THICK HDPE SOLID
X PIPE 23 48 DUROMAXX SOLID 24.00 552.00
CONNECTION QUIKJOINT BELL 23 48 SRPE
CONNECTION QUIKJOINT SPIGOT 25 48 SRPE
CONNECTION QUIKJOINT GASKET 25 48 GASKET
2'-3" 2'-0"
3'-8"
2'-10"
2'-0" 4'-81
4" 2'-0"
2'-10"
3'-8"
2'-0"
2'-3"
6'-4"
4'-3"
3'-11 2"
4"
1'-3"
9"
1" THICK HDPE PLATE WEDGE DIVERTER
WELDED TO THE INSIDE OF THE TEE
WITH A UPPER AND LOWER WEDGE
DUROMAXX QUICKJOINT BELLDUROMAXX
QUICKJOINT
SPIGOTS
2'-111 4"
4'-81 4"
(B1) 48"Ø DUROMAXX STUB
FITTING "B" MANIFOLD TEE/WYE DETAIL
SCALE: 1"=4'
45°45°
JAP
CHECKED:
DRAWN:DESIGNED:
APPROVED:
I:\ M
ER
LI
N \P
R O
JE
C
T\
AC
TI
VE
\8
0\
\8
4-
0- D
M
AX
X- C
O N
-A .D
W G
/2
/2
9:
A
M
SHEET NO.:
OF 5
7/2/2024 DATE:PROJECT No.:
808414 SEQ. No.:
2DRAWING
REVISION DESCRIPTIONDATEMARK BY
- 808414-010
AL FISH & WILDLIFE
EUFAULA, AL
SITE DESIGNATION: 48IN OUTFALL
The design and information shown on this drawing is provided as a service to the project owner, engineer and contractor by Contech Engineered Solutions LLC ("Contech"). Neither this drawing, nor any part thereof, may be used, reproduced or modified in any manner without the prior written consent of Contech. Failure to comply is done at the user's own risk and Contech expressly disclaims any liability or responsibility for such use.
If discrepancies between the supplied information upon which the drawing is based and actual field conditions are encountered as site work progresses, these discrepancies must be reported to Contech immediately for re-evaluation of the design. Contech accepts no liability for designs based on missing, incomplete or inaccurate information supplied by others.
CONSTRUCTION LOADS:
FOR TEMPORARY CONSTRUCTION VEHICLE LOADS, AN EXTRA AMOUNT OF COMPACTED COVER MAY
BE REQUIRED OVER THE TOP OF THE PIPE. THE HEIGHT-OF-COVER SHALL MEET THE MINIMUM
REQUIREMENTS SHOWN IN THE TABLE BELOW. THE USE OF HEAVY CONSTRUCTION EQUIPMENT
NECESSITATES GREATER PROTECTION FOR THE PIPE THAN FINISHED GRADE COVER MINIMUMS FOR
NORMAL HIGHWAY TRAFFIC.
FINISHED
GRADE
HEIGHT OF COVER
*MINIMUM COVER MAY VARY, DEPENDING ON LOCAL CONDITIONS.
THE CONTRACTOR MUST PROVIDE THE ADDITIONAL COVER
REQUIRED TO AVOID DAMAGE TO THE PIPE. MINIMUM COVER IS
MEASURED FROM THE TOP OF THE PIPE TO THE TOP OF THE
MAINTAINED CONSTRUCTION ROADWAY SURFACE.
TEMPORARY COVER
FOR CONSTRUCTION
LOADS
DIAMETERS
AXLE LOADS (kips)
18-50 50-75 75-110 110-150
MINIMUM COVER (FT)
12"-42" 2.0 2.5 3.0 3.0
48"-72" 3.0 3.5 3.5 4.0
84"-96" 3.0 3.5 4.0 4.5
108"-120" 3.5 4.0 4.5 5.0
JAP
CHECKED:
DRAWN:DESIGNED:
APPROVED:
I:\ M
ER
LI
N \P
R O
JE
C
T\
AC
TI
VE
\8
0\
\8
4-
0- D
M
AX
X- C
O N
-A .D
W G
/2
/2
9:
A
M
SHEET NO.:
OF 5
7/2/2024 DATE:PROJECT No.:
808414 SEQ. No.:
S3REVISION DESCRIPTIONDATEMARK BY
- 808414-010
AL FISH & WILDLIFE
EUFAULA, AL
SITE DESIGNATION: 48IN OUTFALL
The design and information shown on this drawing is provided as a service to the project owner, engineer and contractor by Contech Engineered Solutions LLC ("Contech"). Neither this drawing, nor any part thereof, may be used, reproduced or modified in any manner without the prior written consent of Contech. Failure to comply is done at the user's own risk and Contech expressly disclaims any liability or responsibility for such use.
If discrepancies between the supplied information upon which the drawing is based and actual field conditions are encountered as site work progresses, these discrepancies must be reported to Contech immediately for re-evaluation of the design. Contech accepts no liability for designs based on missing, incomplete or inaccurate information supplied by others.
NOTES:
1. ALL ELEVATIONS, DIMENSIONS AND LOCATIONS OF RISERS AND INLETS, SHALL BE VERIFIED BY THE ENGINEER OF RECORD (E.O.R.) OR OWNER DURING DESIGN & CONTRACT PHASE OF PROJECT. IF ELEVATIONS AND DESIGN INFORMATION IS NOT PROVIDED BY E.O.R. OR
OWNER, THE PROJECT CANNOT BE RELEASED FOR FABRICATION.
2. THIS PROJECT IS FOR XXXØ DUROMAXX.
3. DESIGN SERVICE LIFE OF TANK IS TO BE SPECIFIED BY E.O.R. OR OWNER DURING DESIGN PHASE OF PROJECT, AND WILL BE REVIEWED BY
MANUFACTURER.
4. ANY TESTING OF THE TANK WILL NEED TO BE SPECIFIED BY E.O.R. OR OWNER DURING DESIGN PHASE OF PROJECT.
5. ALL WATER TABLE ELEVATIONS ARE TO BE ACCURATELY PROVIDED BY E.O.R. OR OWNER PRIOR TO CONTRACT/FINAL DESIGN PHASE OF
PROJECT.
6. TOTAL HEIGHT OF COVER AND DEPTHS OF THE TYPE OF PAVEMENT TO BE USED ARE TO BE PROVIDED BY E.O.R. OR OWNER DURING
PROPOSAL & CONTRACT PHASES.
7. INTERNAL OPERATIONAL DESIGN PRESSURES (IF ANY) ARE TO BE PROVIDED BY E.O.R. OR OWNER TO THE MANUFACTURER DURING
INITIAL DESIGN PHASE TO PROVIDE PROPER DESIGN OF THE TANK.
8. DESIGN INFORMATION FOR SURGE PRESSURES THAT CAN BE SEEN DURING OPERATION OF THE SYSTEM AS REQUIRED BY E.O.R. OR
OWNER WILL ALSO NEED TO BE PROVIDED DURING DESIGN PHASE OF THE PROJECT.
9. DESIGN INFORMATION AS TO WATER TEMPERATURE (IF ABOVE NORMAL EFFLUENT TEMPERATURES) WILL NEED TO BE PROVIDED BY
E.O.R. OR OWNER DURING DESIGN PHASE OF PROJECT.
10. IF INLET OR OUTLET PIPES NEED TO HAVE GREATER THAN 4PSI JOINTS FOR FIELD PIPE CONNECTIONS, THE USE OF FLANGED ADAPTERS
WILL NEED TO BE SPECIFIED BY E.O.R. OR OWNER DURING DESIGN PHASE OF PROJECT.
11. ALL TANK LATERALS (PIPE STUBS), RISERS & VENTS ARE CONSTRUCTED USING HDPE M294, DR32.5 & DR17 UNLESS OTHERWISE NOTED.
12. ALL PIPE DIMENSIONS ARE SUBJECT TO MANUFACTURERS TOLERANCES.
13. SYSTEM IS DESIGNED FOR H20 AND H25 LOADING.
14. CONSIDERATIONS FOR CONSTRUCTION EQUIPMENT LOADS MUST BE TAKEN INTO ACCOUNT. SEE DETAIL ON THIS PAGE.
15. ANTI-FLOTATION PROVISIONS DUE TO HIGH GROUNDWATER OR OTHER FLOTATION CONCERNS ARE SITE-SPECIFIC DESIGN
CONSIDERATIONS AND SHALL BE SPECIFIED BY ENGINEER OF RECORD.
SCOPE
THIS SPECIFICATION DESCRIBES DUROMAXX PIPE FOR USE IN MULTIPLE APPLICATIONS IN 30" (750 MM) THROUGH 120" (3000 MM) NOMINAL
DIAMETERS.
DESCRIPTION
DUROMAXX IS A REINFORCED POLYETHYLENE PIPE WITH A SMOOTH WATERWAY WALL AND EXTERIOR PROFILE THAT IS REINFORCED WITH HIGH STRENGTH GALVANIZED STEEL RIBS. THE CONTINUOUS REINFORCING RIBS ARE COMPLETELY ENCASED WITHIN THE POLYETHYLENE PROFILE. DUROMAXX IS MANUFACTURED USING A HELICAL WINDING PROCESS THAT RESULTS IN A CONTINUOUSLY FUSION WELDED CIRCUMFERENTIAL LAP SEAM. THE PIPE PROFILE IS MANUFACTURED USING A HIGH QUALITY PRESSURE-RATED THERMOPLASTIC MEETING THE REQUIREMENTS OF ASTM F2562 “STANDARD SPECIFICATION FOR STEEL REINFORCED THERMOPLASTIC RIBBED PIPE AND FITTINGS FOR NON-PRESSURE DRAINAGE AND SEWERAGE”. FOR THE PURPOSE OF HYDRAULIC DESIGN, THE RECOMMENDED MANNING'S "N" VALUE SHALL BE
0.012 FOR PIPE DIAMETERS INCLUDED WITHIN THIS SPECIFICATION. PIPE LENGTH & ALL DIMENSIONS SHOWN ARE SUBJECT TO
MANUFACTURERS TOLERANCES OF ±1% ACCORDING TO ASTM F2562.
MATERIAL PROPERTIES
VIRGIN HIGH DENSITY POLYETHYLENE PRESSURE-RATED RESINS ARE USED TO MANUFACTURE DUROMAXX PIPE. RESINS SHALL CONFORM TO THE MINIMUM REQUIREMENTS OF CELL CLASSIFICATION 345464 C AS DEFINED AND DESCRIBED IN THE LATEST VERSION OF ASTM D3350
“STANDARD SPECIFICATION FOR POLYETHYLENE PLASTICS PIPE AND FITTINGS MATERIALS”.
FITTINGS
ALL FITTINGS SHALL BE FABRICATED FROM DUROMAXX PIPE. ANY FITTINGS 30"Ø AND BELOW WILL BE HDPE PIPE.
ALL FABRICATION OF THE PRODUCT SHALL OCCUR WITHIN THE UNITED STATES.
INSTALLATION SPECIFICATION
PRE-CONSTRUCTION MEETING
PRIOR TO INSTALLATION OF THE DRAINAGE SYSTEM A PRE-CONSTRUCTION
MEETING SHALL BE CONDUCTED. THOSE REQUIRED TO ATTEND ARE THE
SUPPLIER OF THE DRAINAGE SYSTEM, THE GENERAL CONTRACTOR, SUB CONTRACTORS AND THE ENGINEER.
INSTALLATION OF PIPE:
IT IS THE RESPONSIBILITY OF THE CONTRACTOR AND/OR PROJECT ENGINEER TO ENSURE THAT ALL QUESTIONS ABOUT INSTALLATION ARE ADDRESSED PRIOR TO APPROVAL OF SYSTEM. ALL DETAILS FOR INSTALLATION ARE LOCATED IN THIS DRAWING PACKAGE ANY QUESTIONS CONCERNING THESE STANDARD DETAILS CAN BE ADDRESSED BY YOUR CONTECH REPRESENTATIVE PRIOR TO APPROVAL.
BACKFILL SHALL BE PLACED TO THE PROPER ELEVATION OVER THE SYSTEM AS OUTLINED IN THE PLANS. MINIMUM COVER FOR CONSTRUCTION LOADING NEEDS TO BE DETERMINED BASED ON THE TYPE OF EQUIPMENT THAT IS PLANNED FOR CONSTRUCTION. PROPER COVER FOR CONSTRUCTION EQUIPMENT IS DETAILED IN THE CONSTRUCTION LOADING DIAGRAM LOCATED ON THIS PAGE.
CONSTRUCTION LOADING DIAGRAM
N.T.S
BELL DETAIL
SPIGOT DETAIL
BELL
LENGTH
BE
LL
E N
D M
AX
IM
U M
O U
TS
ID
E D
IA
M
ET
ER
POLYETHYLENE
ENCAPSULATED
STEEL RETAINING
BAND
POLYETHYLENE
ENCAPSULATED STEEL
RETAINING BAND
NOMINAL PIPE
DIA. (in)
BELL O.D.
(in)
BELL
LENGTH
(in)-MAX
30 33.9 10.74
36 39.8 10.74
42 45.7 10.74
48 52.3 10.74
54 58.2 10.74
60 64.1 10.74
66 70.9 10.74
72 76.8 10.74
78 82.7 10.74
84 88.6 10.74
96 100.4 10.74
108 112.3 10.74
120 124.1 10.74
ALL JOINTS ARE 10.8 psi
GASKETS
HDPE
SPIGOT
DUROMAXX BELL
DUROMAXX QUICKJOINT™
BELL & SPIGOT CONNECTION
GASKET
QUIKJOINT BELL & SPIGOT CONNECTION DETAIL
NOT TO SCALE
TM
1. MINIMUM TRENCH WIDTH MUST ALLOW ROOM FOR PROPER COMPACTION OF HAUNCH MATERIALS UNDER PIPE. MIN. WIDTH = (1.25 x
DIAMETER) + 12" (FOLLOW ASTM D2321)
1a. MINIMUM EMBANKMENT WIDTH IS 3 PIPE DIAMETERS BUT NO LESS THAN 2' OUTSIDE OF SPRINGLINE.
2. FOUNDATION SHALL BE WELL CONSOLIDATED & STABLE.
3. ENGINEER TO DETERMINE IF BEDDING IS REQUIRED. BEDDING MATERIAL SHALL BE A RELATIVELY LOOSE MATERIAL THAT IS ROUGHLY
SHAPED TO FIT THE BOTTOM OF THE PIPE, 4" TO 6" IN DEPTH.
4. DUROMAXX STEEL REINFORCED (SRPE) PIPE.
5. HAUNCH ZONE MATERIAL SHALL BE HAND SHOVELED OR SHOVEL SLICED INTO PLACE TO ALLOW FOR PROPER COMPACTION.
5a. INITIAL BACKFILL FOR PIPE EMBEDMENT MATERIAL TO MEET ASTM D2321 CLASS I, II, III OR APPROVED EQUAL, COMPACTED TO 90% STANDARD PROCTOR (NATIVE MATERIAL CAN BE UTILIZED THAT MEETS ASTM D2321 OR APPROVED EQUAL).
· ALL LIFTS PLACED IN CONTROLLED MANNER. TO PREVENT UNEVEN LOADING, IT IS RECOMMENDED THAT LIFTS NOT EXCEED 8"
UNCOMPACTED LIFT HEIGHTS.
6. INITIAL BACKFILL ABOVE PIPE MAY INCLUDE ROAD BASE MATERIAL AND RIGID PAVEMENT (IF APPLICABLE), MINIMUM COVER STILL
APPLIES, OTHERWISE:
6" MINIMUM FOR PIPE DIAMETERS 30" - 60"
12" MINIMUM FOR PIPE DIAMETERS 66" - 96"
6a. HEIGHT OF COMPACTED COVER PER DIAMETER FOR CONVENTIONAL HIGHWAY LOADS (DISTANCE MEASURED FROM TOP OF PIPE TO
BOTTOM OF FLEXIBLE PAVEMENT OR TOP OF RIGID PAVEMENT):
12" MINIMUM FOR PIPE DIAMETERS 30" - 60"
18" MINIMUM FOR PIPE DIAMETER 66" - 78"
24" MINIMUM FOR PIPE DIAMETERS 84" - 96"
7. FINAL BACKFILL MATERIAL SELECTION AND COMPACTION REQUIREMENTS PER THE PROJECT PLANS, SPECIFICATIONS. ENGINEER OF
RECORD.
NOTES:
· ENGINEER TO DETERMINE IF GEOTEXTILE SHOULD BE USED TO PREVENT SOIL MIGRATION.
· FOR MULTIPLE BARREL INSTALLATION THE RECOMMENDED STANDARD SPACING BETWEEN PARALLEL PIPE RUNS SHALL BE = PIPE DIA./2
OR 3' FOR PIPE DIAMETERS 72" AND LARGER. CONTACT YOUR CONTECH REPRESENTATIVE FOR NONSTANDARD SPACING.
· BACKFILL REQUIREMENTS SHALL FOLLOW ASTM D2321. IN THE EVENT OF DISCREPANCIES, ASTM D2321 SHALL SUPERCEDE THIS DETAIL.
DIAMETER MAX
COVER*
75% MAX
COVER**
30"-42" 50'-0" 37'-6"
48"-96" 30'-0" 22'-6"
*FOR INITIAL BACKFILL USE ASTM D2321,
CLASS I, II MATERIAL.
**REDUCED MAX. COVER WHEN USING ASTM
D2321 CLASS III MATERIAL IN
TRENCH/HAUNCH ZONE OR FOR FIRST
BACKFILL.
INITIAL FILL ENVELOPE
FINAL BACKFILL
INITIAL BACKFILL
HAUNCH ZONE
PIPE ZONE
6a
BEDDING
FOUNDATION
PI
PE
E M
BE
D
M
EN
T
DIAMETER
IN SITU
1 1a
D/25a
INSTALLATION/BACKFILL DETAIL
NOT TO SCALE
EMBANKMENT CONDITIONTRENCH CONDITION
JAP
CHECKED:
DRAWN:DESIGNED:
APPROVED:
I:\ M
ER
LI
N \P
R O
JE
C
T\
AC
TI
VE
\8
0\
\8
4-
0- D
M
AX
X- C
O N
-A .D
W G
/2
/2
9:
A
M
SHEET NO.:
OF 5
7/2/2024 DATE:PROJECT No.:
808414 SEQ. No.:
808414-010-DMAXX-CON-A
S4REVISION DESCRIPTIONDATEMARK BY
- 808414-010
AL FISH & WILDLIFE
EUFAULA, AL
SITE DESIGNATION: 48IN OUTFALL
The design and information shown on this drawing is provided as a service to the project owner, engineer and contractor by Contech Engineered Solutions LLC ("Contech"). Neither this drawing, nor any part thereof, may be used, reproduced or modified in any manner without the prior written consent of Contech. Failure to comply is done at the user's own risk and Contech expressly disclaims any liability or responsibility for such use.
If discrepancies between the supplied information upon which the drawing is based and actual field conditions are encountered as site work progresses, these discrepancies must be reported to Contech immediately for re-evaluation of the design. Contech
MANIFOLD TEE REINFORCEMENT INSTALLATION DETAIL
NOT TO SCALE
CLSM EXTENTS
PLAN VIEW
ELEVATION VIEW
MAINLINE DUROMAXX PIPE
DURING INSTALLATION CLSM IS TO
BE INSTALLED FOR ADDITIONAL
REINFORCEMENT OF THE PIPE
INLET AREAS
DUROMAXX PIPE STUB
1'-0"
1'-0"
1'-0"
C1. INITIAL BACKFILL FOR PIPE EMBEDMENT MATERIAL TO MEET
ASTM D2321 CLASS I OR APPROVED EQUAL, COMPACTED TO 90%
STANDARD PROCTOR (NATIVE MATERIAL CAN BE UTILIZED THAT
MEETS ASTM D2321 OR APPROVED EQUAL).
· ALL LIFTS PLACED IN CONTROLLED MANNER. TO PREVENT
UNEVEN LOADING, IT IS RECOMMENDED THAT LIFTS NOT
EXCEED 8" UNCOMPACTED LIFT HEIGHTS.
C2. DUROMAXX REINFORCED (SRPE) PIPE.
C3. MINIMUM OF 6" OF STABILIZED FILL OVER THE TEE FITTING
C4. STABILIZED BACKFILL MATERIAL SUCH AS CLSM OR CEMENT
STABILIZED SAND. MATERIAL SHALL HAVE A MINIMUM
COMPRESSIVE STRENGTH OF 750 PSI.
C5. BEDDING MATERIAL SHALL BE A RELATIVELY LOOSE COMPACTED
BEDDING MATERIAL THAT IS ROUGHLY SHAPED TO FIT THE
BOTTOM OF THE PIPE, 4" TO 6" IN DEPTH.
C2
C1
C3
C4
DUROMAXX-CLSM BACKFILL DETAIL FOR REINFORCED STUB ON MANIFOLD
C3
C5
JAP
CHECKED:
DRAWN:DESIGNED:
APPROVED:
I:\ M
ER
LI
N \P
R O
JE
C
T\
AC
TI
VE
\8
0\
\8
4-
0- D
M
AX
X- C
O N
-A .D
W G
/2
/2
9:
A
M
SHEET NO.:
OF 5
7/2/2024 DATE:PROJECT No.:
808414 SEQ. No.:
S5REVISION DESCRIPTIONDATEMARK BY
- 808414-010
AL FISH & WILDLIFE
EUFAULA, AL
SITE DESIGNATION: 48IN OUTFALL
The design and information shown on this drawing is provided as a service to the project owner, engineer and contractor by Contech Engineered Solutions LLC ("Contech"). Neither this drawing, nor any part thereof, may be used, reproduced or modified in any manner without the prior written consent of Contech. Failure to comply is done at the user's own risk and Contech expressly disclaims any liability or responsibility for such use.
If discrepancies between the supplied information upon which the drawing is based and actual field conditions are encountered as site work progresses, these discrepancies must be reported to Contech immediately for re-evaluation of the design. Contech
File details come from the government source that posted it. Updated .