METAL LOCKERS 105113 - 1
SECTION 105113 - METAL LOCKERS
PART 1 - GENERAL
1.1 RELATED DOCUMENTS
A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections, apply to this Section.
1.2 SUMMARY
A. Section Includes:
1. Knocked-down athletic lockers.
1.3 ACTION SUBMITTALS
A. Submittals shall comply with the requirements of Section 013300 “Submittal Procedures” and the individual sections specifying the work.
B. Product Data: For each type of metal locker.
1. Include construction details, material descriptions, dimensions of individual components and profiles, and finishes for each type of metal locker and bench.
C. Shop Drawings: For metal lockers.
1. Include plans, elevations, sections, details, and attachments to other work.
2. Show locker trim and accessories.
3. Include locker identification system and numbering sequence.
D. Samples: For each color specified, in manufacturer's standard size.
E. Samples for Initial Selection: Manufacturer's color charts showing the full range of colors available.
1.4 INFORMATIONAL SUBMITTALS
A. Submittals shall comply with the requirements of Section 013300 “Submittal Procedures” and the individual sections specifying the work.
B. Qualification Data: For Installer.
C. Sample Warranty: For special warranty.
METAL LOCKERS 105113 - 2
1.5 CLOSEOUT SUBMITTALS
A. Submittals shall comply with the requirements of Section 013300 “Submittal Procedures” and the individual sections specifying the work.
B. Maintenance Data: For adjusting, repairing, and replacing locker doors and latching mechanisms to include in maintenance manuals.
1.6 DELIVERY, STORAGE, AND HANDLING
A. Do not deliver metal lockers until spaces to receive them are clean, dry, and ready for their installation.
1.7 FIELD CONDITIONS
A. Field Measurements: Verify actual dimensions of recessed openings by field measurements before fabrication.
1.8 COORDINATION
A. Coordinate sizes and locations of bases for metal lockers.
B. Coordinate sizes and locations of framing, blocking, furring, reinforcements, and other related units of work specified in other Sections to ensure that metal lockers can be supported and installed as indicated.
1.9 WARRANTY
A. Special Warranty: Manufacturer agrees to repair or replace components of metal lockers that fail in materials or workmanship, excluding finish, within specified warranty period.
1. Failures include, but are not limited to, the following:
a. Structural failures.
b. Faulty operation of latches and other door hardware.
2. Damage from deliberate destruction and vandalism is excluded.
3. Warranty Period for Knocked-Down Metal Lockers: Two years from date of Substantial
Completion.
METAL LOCKERS 105113 - 3
PART 2 - PRODUCTS
2.1 MANUFACTURERS
A. Source Limitations: Obtain metal lockers, locker benches, and accessories from single source from single locker manufacturer.
2.2 PERFORMANCE REQUIREMENTS
A. Accessibility Requirements: For lockers indicated to be accessible, comply with applicable provisions in the U.S. Architectural & Transportation Barriers Compliance Board's ADA-ABA Accessibility Guidelines.
2.3 KNOCKED-DOWN ATHLETIC LOCKERS
A. Basis-of-Design Product: Subject to compliance with requirements, provide “Heavy Duty Ventilated,” Republic Storage Systems, LLC, or comparable product by one of the following:
1. Art Metal Products.
2. DeBourgh Mfg. Co.
3. General Storage Systems Ltd.
4. Hadrian Manufacturing Inc.
5. List Industries Inc.
6. Lyon Workspace Products, LLC.
7. Olympus Lockers & Storage Products, Inc.
8. Penco Products, Inc.
B. Perforated Doors: One piece; fabricated from 0.075-inch nominal-thickness steel sheet with manufacturer's standard diamond perforations; formed into channel shape with double bend at vertical edges and with right-angle single bend at horizontal edges and latch point (bottom) and right-angle single bend at remaining edges for box lockers.
1. Reinforcement: Manufacturer's standard reinforcing angles, channels, or stiffeners for doors more than 15 inches wide; welded to inner face of doors.
C. Body: Assembled by riveting or bolting body components together. Fabricate from unperforated steel sheet with thicknesses as follows:
1. Tops and Bottoms: 0.060-inch nominal thickness, with single bend at edges.
2. Backs: 0.048-inch nominal thickness.
3. Shelves: 0.060-inch nominal thickness, with double bend at front and single bend at sides and back.
D. Perforated Sides: Fabricated from 0.060-inch nominal-thickness steel sheet with manufacturer's standard diamond perforations.
http://www.specagent.com/Lookup?ulid=712 http://www.specagent.com/Lookup?uid=123457012106 http://www.specagent.com/Lookup?uid=123457012108 http://www.specagent.com/Lookup?uid=123457012109 http://www.specagent.com/Lookup?uid=123457012104 http://www.specagent.com/Lookup?uid=123457012112 http://www.specagent.com/Lookup?uid=123457012110
METAL LOCKERS 105113 - 4
E. Frames: Channel formed; fabricated from 0.060-inch nominal-thickness steel sheet or 0.097-inch nominal-thickness steel angles; lapped and factory welded at corners; with top and bottom main frames factory welded into vertical main frames. Form continuous, integral, full-height door strikes on vertical main frames.
1. Cross Frames for Double-Tier Lockers: Channel formed and fabricated from same material as main frames; welded to vertical main frames.
F. Reinforced Bottoms: Structural channels, formed from 0.060-inch nominal-thickness steel sheet; welded to front and rear of side-panel frames.
G. Hinges: Welded to door and attached to door frame with no fewer than two factory-installed rivets per hinge that are completely concealed and tamper resistant when door is closed;
fabricated to swing 180 degrees; self-closing.
1. Continuous Hinges: Manufacturer's standard, steel; side or top mounted as required by locker configuration.
H. Recessed Door Handle and Latch: Stainless-steel cup with integral door pull, recessed so locking device does not protrude beyond door face; pry and vandal resistant.
1. Multipoint Latching: Finger-lift latch control designed for use with built-in combination locks, built-in cylinder locks, or padlocks; positive automatic latching and prelocking.
a. Latch Hooks: Equip doors 48 inches and higher with three latch hooks and doors less than 48 inches high with two latch hooks; fabricated from 0.120-inch nominal-thickness steel sheet; welded to full-height door strikes; with resilient silencer on each latch hook.
b. Latching Mechanism: Manufacturer's standard, rattle-free latching mechanism and moving components isolated to prevent metal-to-metal contact, and incorporating a prelocking device that allows locker door to be locked while door is open and then closed without unlocking or damaging lock or latching mechanism.
I. Identification Plates: Manufacturer's standard, etched, embossed, or stamped aluminum plates, with numbers and letters at least 3/8 inch high.
J. Hooks: Manufacturer's standard ball-pointed type, aluminum or steel; zinc plated.
K. Filler Panels: Fabricated from 0.048-inch nominal-thickness steel sheet.
L. Boxed End Panels: Fabricated from 0.060-inch nominal-thickness steel sheet.
M. Materials:
1. Cold-Rolled Steel Sheet: ASTM A 1008/A 1008M, Commercial Steel (CS), Type B, suitable for exposed applications.
2. Expanded Metal: ASTM F 1267, Type II (flattened), Class I, 3/4-inch steel mesh, with at least 70 percent open area.
N. Finish: Baked enamel or powder coat.
METAL LOCKERS 105113 - 5
1. Color: As selected by Contracting Officer from manufacturer's full range; one color door, frame and body.
O. Size: Double tier, 12 inches wide by 18 inches deep by 72 inches high.
2.4 FABRICATION
A. Fabricate metal lockers square, rigid, without warp, and with metal faces flat and free of dents or distortion. Make exposed metal edges safe to touch and free of sharp edges and burrs.
1. Form body panels, doors, shelves, and accessories from one-piece steel sheet unless otherwise indicated.
2. Provide fasteners, filler plates, supports, clips, and closures as required for complete installation.
B. Fabricate each metal locker with an individual door and frame; individual top, bottom, and back; and common intermediate uprights separating compartments. Factory weld frame members of each metal locker together to form a rigid, one-piece assembly.
C. Equipment: Provide each locker with an identification plate and the following equipment:
1. Single-Tier Units: Shelf, one double-prong ceiling hook, and two single-prong wall hooks.
D. Knocked-Down Construction: Fabricate metal lockers using nuts, bolts, screws, or rivets for nominal assembly at Project site.
E. Accessible Lockers: Fabricate as follows:
1. Where hooks, coat rods, or additional shelves are provided, locate no higher than 48 inches above the floor.
2. Provide 1 accessible locker as directed by Contracting Officer.
F. Continuous Sloping Tops: Fabricated in lengths as long as practical, without visible fasteners at splice locations; finished to match lockers.
1. Sloping-top corner fillers, mitered.
G. Recess Trim: Fabricated with minimum 2-1/2-inch face width and in lengths as long as practical; finished to match lockers.
H. Filler Panels: Fabricated in an unequal leg angle shape; finished to match lockers. Provide slip-joint filler angle formed to receive filler panel.
I. Boxed End Panels: Fabricated with 1-inch-wide edge dimension, and designed for concealing fasteners and holes at exposed ends of nonrecessed metal lockers; finished to match lockers.
1. Provide one-piece panels for double-row (back-to-back) locker ends.
METAL LOCKERS 105113 - 6
2.5 ACCESSORIES
A. Fasteners: Zinc- or nickel-plated steel, slotless-type, exposed bolt heads; with self-locking nuts or lock washers for nuts on moving parts.
B. Anchors: Material, type, and size required for secure anchorage to each substrate.
1. Provide nonferrous-metal or hot-dip galvanized anchors and inserts on inside face of exterior walls, and elsewhere as indicated, for corrosion resistance.
2. Provide toothed-steel or lead expansion sleeves for drilled-in-place anchors.
PART 3 - EXECUTION
3.1 EXAMINATION
A. Examine walls, floors, and support bases, with Installer present, for compliance with requirements for installation tolerances and other conditions affecting performance of the Work.
B. Prepare written report, endorsed by Installer, listing conditions detrimental to performance of the Work.
C. Proceed with installation only after unsatisfactory conditions have been corrected.
3.2 INSTALLATION
A. General: Install lockers level, plumb, and true; shim as required, using concealed shims.
1. Anchor locker runs at ends and at intervals recommended by manufacturer, but not more than 36 inches o.c. Using concealed fasteners, install anchors through backup reinforcing plates, channels, or blocking as required to prevent metal distortion.
2. Anchor single rows of metal lockers to walls near top of lockers and to floor.
3. Anchor back-to-back metal lockers to floor.
B. Knocked-Down Lockers: Assemble with standard fasteners, with no exposed fasteners on door faces or face frames.
C. Equipment:
1. Attach hooks with at least two fasteners.
2. Attach door locks on doors using security-type fasteners.
3. Identification Plates: Identify metal lockers with identification indicated on Drawings.
a. Attach plates to each locker door, near top, centered, with at least two aluminum rivets.
b. Attach plates to upper shelf of each open-front metal locker, centered, with a least two aluminum rivets.
METAL LOCKERS 105113 - 7
D. Trim: Fit exposed connections of trim, fillers, and closures accurately together to form tight, hairline joints, with concealed fasteners and splice plates.
1. Attach recess trim to recessed metal lockers with concealed clips.
2. Attach filler panels with concealed fasteners. Locate filler panels where indicated on
Drawings.
3. Attach sloping-top units to metal lockers, with closures at exposed ends.
4. Attach boxed end panels using concealed fasteners to conceal exposed ends of nonrecessed metal lockers.
3.3 ADJUSTING
A. Clean, lubricate, and adjust hardware. Adjust doors and latches to operate easily without binding.
3.4 PROTECTION
A. Protect metal lockers from damage, abuse, dust, dirt, stain, or paint. Do not permit use during construction.
B. Touch up marred finishes, or replace metal lockers that cannot be restored to factory-finished appearance. Use only materials and procedures recommended or furnished by locker manufacturer.
END OF SECTION
| PART 1 - GENERAL |
| 1.1 RELATED DOCUMENTS |
| A. Drawings and general provisions of the Contract, including General and Supplementary Conditions and Division 01 Specification Sections, apply to this Section. |
| 1.2 SUMMARY |
| A. Section Includes: |
| 1. Knocked-down athletic lockers. |
| 1.3 ACTION SUBMITTALS |
| A. Submittals shall comply with the requirements of Section 013300 “Submittal Procedures” and the individual sections specifying the work. |
| B. Product Data: For each type of metal locker. |
| 1. Include construction details, material descriptions, dimensions of individual components and profiles, and finishes for each type of metal locker and bench. |
| C. Shop Drawings: For metal lockers. |
| 1. Include plans, elevations, sections, details, and attachments to other work. |
| 2. Show locker trim and accessories. |
| 3. Include locker identification system and numbering sequence. |
| D. Samples: For each color specified, in manufacturer's standard size. |
| E. Samples for Initial Selection: Manufacturer's color charts showing the full range of colors available. |
| 1.4 INFORMATIONAL SUBMITTALS |
| A. Submittals shall comply with the requirements of Section 013300 “Submittal Procedures” and the individual sections specifying the work. |
| B. Qualification Data: For Installer. |
| C. Sample Warranty: For special warranty. |
| 1.5 CLOSEOUT SUBMITTALS |
| A. Submittals shall comply with the requirements of Section 013300 “Submittal Procedures” and the individual sections specifying the work. |
| B. Maintenance Data: For adjusting, repairing, and replacing locker doors and latching mechanisms to include in maintenance manuals. |
| 1.6 DELIVERY, STORAGE, AND HANDLING |
| A. Do not deliver metal lockers until spaces to receive them are clean, dry, and ready for their installation. |
| 1.7 FIELD CONDITIONS |
| A. Field Measurements: Verify actual dimensions of recessed openings by field measurements before fabrication. |
| 1.8 COORDINATION |
| A. Coordinate sizes and locations of bases for metal lockers. |
| B. Coordinate sizes and locations of framing, blocking, furring, reinforcements, and other related units of work specified in other Sections to ensure that metal lockers can be supported and installed as indicated. |
| 1.9 WARRANTY |
| A. Special Warranty: Manufacturer agrees to repair or replace components of metal lockers that fail in materials or workmanship, excluding finish, within specified warranty period. |
| 1. Failures include, but are not limited to, the following: |
| a. Structural failures. |
| b. Faulty operation of latches and other door hardware. |
| 2. Damage from deliberate destruction and vandalism is excluded. |
| 3. Warranty Period for Knocked-Down Metal Lockers: Two years from date of Substantial Completion. |
| PART 2 - PRODUCTS |
| 2.1 MANUFACTURERS |
| A. Source Limitations: Obtain metal lockers, locker benches, and accessories from single source from single locker manufacturer. |
| 2.2 PERFORMANCE REQUIREMENTS |
| A. Accessibility Requirements: For lockers indicated to be accessible, comply with applicable provisions in the U.S. Architectural & Transportation Barriers Compliance Board's ADA-ABA Accessibility Guidelines. |
| 2.3 KNOCKED-DOWN ATHLETIC LOCKERS |
| A. 42TUBasis-of-Design Product:U42T Subject to compliance with requirements, provide “Heavy Duty Ventilated,” Republic Storage Systems, LLC, or comparable product by one of the following: |
| 1. 42TArt Metal Products42T. |
| 2. 42TDeBourgh Mfg. Co42T. |
| 3. 42TGeneral Storage Systems Ltd42T. |
| 4. 42THadrian Manufacturing Inc42T. |
| 5. 42TList Industries Inc42T. |
| 6. 42TLyon Workspace Products, LLC42T. |
| 7. 42TOlympus Lockers & Storage Products, Inc42T. |
| 8. 42TPenco Products, Inc42T. |
| B. Perforated Doors: One piece; fabricated from 34T0.075-inch34T nominal-thickness steel sheet with manufacturer's standard diamond perforations; formed into channel shape with double bend at vertical edges and with right-angle single bend at horizont... |
| 1. Reinforcement: Manufacturer's standard reinforcing angles, channels, or stiffeners for doors more than 34T15 inches34T wide; welded to inner face of doors. |
| C. Body: Assembled by riveting or bolting body components together. Fabricate from unperforated steel sheet with thicknesses as follows: |
| 1. Tops and Bottoms: 34T0.060-inch34T nominal thickness, with single bend at edges. |
| 2. Backs: 34T0.048-inch34T nominal thickness. |
| 3. Shelves: 34T0.060-inch34T nominal thickness, with double bend at front and single bend at sides and back. |
| D. Perforated Sides: Fabricated from 34T0.060-inch34T nominal-thickness steel sheet with manufacturer's standard diamond perforations. |
| E. Frames: Channel formed; fabricated from 34T0.060-inch34T nominal-thickness steel sheet or 34T0.097-inch34T nominal-thickness steel angles; lapped and factory welded at corners; with top and bottom main frames factory welded into vertical main frame... |
| 1. Cross Frames for Double-Tier Lockers: Channel formed and fabricated from same material as main frames; welded to vertical main frames. |
| F. Reinforced Bottoms: Structural channels, formed from 34T0.060-inch34T nominal-thickness steel sheet; welded to front and rear of side-panel frames. |
| G. Hinges: Welded to door and attached to door frame with no fewer than two factory-installed rivets per hinge that are completely concealed and tamper resistant when door is closed; fabricated to swing 180 degrees; self-closing. |
| 1. Continuous Hinges: Manufacturer's standard, steel; side or top mounted as required by locker configuration. |
| H. Recessed Door Handle and Latch: Stainless-steel cup with integral door pull, recessed so locking device does not protrude beyond door face; pry and vandal resistant. |
| 1. Multipoint Latching: Finger-lift latch control designed for use with built-in combination locks, built-in cylinder locks, or padlocks; positive automatic latching and prelocking. |
| a. Latch Hooks: Equip doors 34T48 inches34T and higher with three latch hooks and doors less than 34T48 inches34T high with two latch hooks; fabricated from 34T0.120-inch34T nominal-thickness steel sheet; welded to full-height door strikes; with resil... |
| b. Latching Mechanism: Manufacturer's standard, rattle-free latching mechanism and moving components isolated to prevent metal-to-metal contact, and incorporating a prelocking device that allows locker door to be locked while door is open and then clo... |
| I. Identification Plates: Manufacturer's standard, etched, embossed, or stamped aluminum plates, with numbers and letters at least 34T3/8 inch34T high. |
| J. Hooks: Manufacturer's standard ball-pointed type, aluminum or steel; zinc plated. |
| K. Filler Panels: Fabricated from 34T0.048-inch34T nominal-thickness steel sheet. |
| L. Boxed End Panels: Fabricated from 34T0.060-inch34T nominal-thickness steel sheet. |
| M. Materials: |
| 1. Cold-Rolled Steel Sheet: ASTM A 1008/A 1008M, Commercial Steel (CS), Type B, suitable for exposed applications. |
| 2. Expanded Metal: ASTM F 1267, Type II (flattened), Class I, 34T3/4-inch34T steel mesh, with at least 70 percent open area. |
| N. Finish: Baked enamel or powder coat. |
| 1. Color: As selected by Contracting Officer from manufacturer's full range; one color door, frame and body. |
O. Size: Double tier, 12 inches wide by 18 inches deep by 72 inches high.
| 2.4 FABRICATION |
| A. Fabricate metal lockers square, rigid, without warp, and with metal faces flat and free of dents or distortion. Make exposed metal edges safe to touch and free of sharp edges and burrs. |
| 1. Form body panels, doors, shelves, and accessories from one-piece steel sheet unless otherwise indicated. |
| 2. Provide fasteners, filler plates, supports, clips, and closures as required for complete installation. |
| B. Fabricate each metal locker with an individual door and frame; individual top, bottom, and back; and common intermediate uprights separating compartments. Factory weld frame members of each metal locker together to form a rigid, one-piece assembly. |
| C. Equipment: Provide each locker with an identification plate and the following equipment: |
| 1. Single-Tier Units: Shelf, one double-prong ceiling hook, and two single-prong wall hooks. |
| D. Knocked-Down Construction: Fabricate metal lockers using nuts, bolts, screws, or rivets for nominal assembly at Project site. |
| E. Accessible Lockers: Fabricate as follows: |
| 1. Where hooks, coat rods, or additional shelves are provided, locate no higher than 34T48 inches34T above the floor. |
| F. Continuous Sloping Tops: Fabricated in lengths as long as practical, without visible fasteners at splice locations; finished to match lockers. |
| 1. Sloping-top corner fillers, mitered. |
| G. Recess Trim: Fabricated with minimum 34T2-1/2-inch34T face width and in lengths as long as practical; finished to match lockers. |
| H. Filler Panels: Fabricated in an unequal leg angle shape; finished to match lockers. Provide slip-joint filler angle formed to receive filler panel. |
| I. Boxed End Panels: Fabricated with 34T1-inch-34Twide edge dimension, and designed for concealing fasteners and holes at exposed ends of nonrecessed metal lockers; finished to match lockers. |
| 1. Provide one-piece panels for double-row (back-to-back) locker ends. |
| 2.5 ACCESSORIES |
| A. Fasteners: Zinc- or nickel-plated steel, slotless-type, exposed bolt heads; with self-locking nuts or lock washers for nuts on moving parts. |
| B. Anchors: Material, type, and size required for secure anchorage to each substrate. |
| 1. Provide nonferrous-metal or hot-dip galvanized anchors and inserts on inside face of exterior walls, and elsewhere as indicated, for corrosion resistance. |
| 2. Provide toothed-steel or lead expansion sleeves for drilled-in-place anchors. |
| PART 3 - EXECUTION |
| 3.1 EXAMINATION |
| A. Examine walls, floors, and support bases, with Installer present, for compliance with requirements for installation tolerances and other conditions affecting performance of the Work. |
| B. Prepare written report, endorsed by Installer, listing conditions detrimental to performance of the Work. |
| C. Proceed with installation only after unsatisfactory conditions have been corrected. |
| 3.2 INSTALLATION |
| A. General: Install lockers level, plumb, and true; shim as required, using concealed shims. |
| 1. Anchor locker runs at ends and at intervals recommended by manufacturer, but not more than 34T36 inches34T o.c. Using concealed fasteners, install anchors through backup reinforcing plates, channels, or blocking as required to prevent metal distort... |
| 2. Anchor single rows of metal lockers to walls near top of lockers and to floor. |
| 3. Anchor back-to-back metal lockers to floor. |
| B. Knocked-Down Lockers: Assemble with standard fasteners, with no exposed fasteners on door faces or face frames. |
| C. Equipment: |
| 1. Attach hooks with at least two fasteners. |
| 2. Attach door locks on doors using security-type fasteners. |
| 3. Identification Plates: Identify metal lockers with identification indicated on Drawings. |
| a. Attach plates to each locker door, near top, centered, with at least two aluminum rivets. |
| b. Attach plates to upper shelf of each open-front metal locker, centered, with a least two aluminum rivets. |
| D. Trim: Fit exposed connections of trim, fillers, and closures accurately together to form tight, hairline joints, with concealed fasteners and splice plates. |
| 1. Attach recess trim to recessed metal lockers with concealed clips. |
| 2. Attach filler panels with concealed fasteners. Locate filler panels where indicated on Drawings. |
| 3. Attach sloping-top units to metal lockers, with closures at exposed ends. |
| 4. Attach boxed end panels using concealed fasteners to conceal exposed ends of nonrecessed metal lockers. |
| 3.3 ADJUSTING |
| A. Clean, lubricate, and adjust hardware. Adjust doors and latches to operate easily without binding. |
| 3.4 PROTECTION |
| A. Protect metal lockers from damage, abuse, dust, dirt, stain, or paint. Do not permit use during construction. |
| B. Touch up marred finishes, or replace metal lockers that cannot be restored to factory-finished appearance. Use only materials and procedures recommended or furnished by locker manufacturer. |
File details come from the government source that posted it. Updated .