14-!-CS27009-Stage II-26360490-DFCM Addendum 3.pdf
PDF 1 MB Posted
- Solicitation number
- CS27009-Stage II
- Issued by
- Weber County, Utah
About this file
This is Addendum #3 to the construction bid documents for the Northern Utah Veterans Cemetery project, issued by the Utah Division of Facilities Construction and Management (DFCM) on August 27, 2026. The project, identified as DFCM Project #26360490 with Federal Aid Identifier UT-19-05, involves construction of a new veterans memorial cemetery in Washington Terrace, Utah. Work scope includes site improvements, utility infrastructure, hardscape, irrigation, landscaping installation, and building construction. The addendum addresses contractor questions and clarifications regarding project specifications, materials, and responsibilities. Key clarifications include confirmation that geopiers are required for ground improvement and support (helical piers are not acceptable alternatives); internal winches are required for flagpoles (not external halyards); the July 15, 2026 CMT geotechnical report supersedes previous versions; DFCM will contract independently for geotechnical observations, density testing, and special inspections; 14 oversized and 486 standard burial crypts comprise the 500-crypt total; and the contractor is responsible for 50-foot and 40-foot flagpole installation with all associated components. The addendum confirms the project requires Davis Bacon prevailing wages, certified payroll, and compliance with Buy America Build America provisions. Bidders must acknowledge receipt of the addendum with their bid submission.
The construction cost estimate has been updated from $12,000,000 to $13,800,000. Contractors must submit separate bid line items for pre-placed lawn crypt manufacture and delivery (funded from a different source) and a $25,000 allowance for spring water mitigation at the maintenance yard. Revised mechanical, plumbing, and architectural sheets (PB101, PB601, AB171, and AC601) are included addressing mop sink configurations, plumbing fixture schedules, roof fence installations for vent protection, and updated wall details with air barriers and high-temperature ice and water barriers. Additional deliverables include CPT geotechnical data files in CSV format (CPT-1, CPT-2, CPT-3) and a detailed bid schedule required by the VCGP Grant for processing. DFCM retains responsibility for utility permitting and connection fees, while contractors are responsible for SWPPP and fugitive dust permits and related fees. The most recent APWA Utah Chapter 2026 Edition applies to the bid and construction, except for work in public rights-of-way or utility easements, which must comply with applicable jurisdiction requirements.
View the file
Other files
Show all 15
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
DFCM Addendum Cover Page, 2.26.2026
DFCM Addendum #3 Reference: Northern Utah Veterans Cemetery DFCM Project #26360490 U3P Event #CS27009-Stage II
Date: August 27, 2026
To: Contractors
From: The Division of Facilities Construction and Management
Note:
This
Addendum shall be included as part of the Contract Documents. Items in this Addendum apply to all drawings and specification sections whether referenced or not involving the portion of the work added, deleted, modified, or otherwise addressed in the Addendum. Bidders are required to acknowledge receipt of this Addendum when their bid is submitted. Failure to do so may subject the Bidder to disqualification.
Addendum Items
Solicitation Schedule Changes: There are no changes to the Solicitation Schedule in this addendum.
DFCM Addendum Items: N/A
Click to enter text Click to enter text Click to enter text
A/E Addendum Items: A/E Addendum # 2 Contractor Questions/Responses: + drawings Contract Document Clarifications/Revisions: +drawings Bid Schedule has been added-attached.
CSV Files added under Supporting Documents
Total Attached Pages: 9
Jillian Rafferty Additional lines for DFCM Addendum Items, the boxes for page numbers, and the line under A/E Addendum # are transparent so you don’t need to delete them if not needed.
A D D E N D U M
S I T E A N D L A N D S C A P E A R C H I T E C T S
To: Bidding Contractors Date: August 26, 2026
Company: From: Mathew Winward
GBD Project No: U26-010
Project: Northern Utah Veterans Cemetery – DFCM #26360490
Re: Bidding Addendum #3
Distribution: Bidding Contractors, DFCM, File
Description / Remarks:
Bidding Addendum
Contractor Questions/Responses:
Question: CPT Data - There are several CPT soundings in the available geotechnical report. Can you please provide the electronic CPT data for these soundings? This will help to analyze for liquefaction.
Answer: Geotechnical Engineer has provided CPT Data. It will be provided as part of this addendum as .CSV files and includes CPT-1.csv, CPT-2.csv, and CPT-3.csv files.
Question: Would helical piers be an acceptable alternative to the geopiers?
Answer: No, the geopiers are for ground improvement as well as support.
Question: The drawings (Product & Material) call out for the ESR, which is an external halyard. However, the specifications (2.3 part B) call out for an internal winch. These systems are priced very differently.
Which system does the owner want?
Answer: Internal Winch is required. 40’ Tall Flagpole model is IWM40D82-AA; 50’ Flagpole Model # is IWM50D13-AA. Specification section 107500 2.1.B.3 is revised as Follows: “Outside Diameter of Butt: 10 inches for 50 foot pole; 8 inches for 40 foot pole.”
Question: For bid bond, who is actual owner of the project, state or government Answer: Utah Division of Facilities and Construction Management
Question: Please confirm that the July 15, 2026 CMT geotechnical report supersedes the June 10 report referenced by the structural documents.
Answer: Yes, the July 15, 2026 CMT Geotechnical Report included with the Technical Specifications supersedes the June 10 report referenced by the structural documents. We can also confirm that the updated report does not require any updates to the structural documents.
Question: Please clarify responsibility and payment for geotechnical observation, density testing, special inspections, and CMT services. Some documents indicate this is an owner-provided inspection, while others direct the contractor to employ geotechnical personnel.
Answer: DFCM will contract with independent firm(s) to provide required geotechnical observations, density testing and special inspections.
Question: Please confirm the number of standard versus oversized burial crypts and whether the oversized crypts are included within the total quantity of 500.
Answer: 14 Oversized, 486 standard size for a total of 500 crypts. See LB-403 Burial Layout – Burial Section B Enlargement.
Question: Please confirm delivery schedule, location, unloading procedures, storage responsibility, inspection protocol, and damage / replacement responsibility for government-furnished niche covers and memorial plaques.
Answer: Niche Covers and Memorial Wall Plaques will be ordered by Utah Department of Veterans and Memorial Affairs 60-90 days prior to time covers/plaques will be needed on the site. Contractor will need to coordinate with Design Team, DFCM, and Utah DVMA for proper timing of ordering. Contractor will be responsible to assist with unloading niche cover/memorial wall plaques and shall visually inspect niche covers/memorial plaques upon delivery for evidence of damage but complete inspection of all plaques may not be possible due to stacking/palletization. Contractor will also need to safely store niche covers/memorial wall plaques until installation. Damage to niche covers/memorial wall plaques caused by contractor or contractor’s negligence will be the contractors responsibility.
Question: The documents mention that the flagpole is government furnished / government installed.
Please confirm whether the government will also provide / install the foundation, sleeve, erection, electrical / grounding, hardware, and accessories for the flagpole.
Answer: There are multiple flagpoles on the project. A 50’ Flagpole, two 40’ flagpoles, and the “Avenue of Flags – Flag Pole Base, which notates that the T20 Flagpole is provided by owner. Contractor is responsible to furnish and install the 50’ flagpole and 40’ flagpoles and all necessary foundation, sleeve, erection, electrical/grounding, hardware, and accessories for the flagpole as called out and detailed in the plans and specifications. The “Avenue of Flags – Flag Pole Bases” requires the contractor to install the flagpole base, sleeve, filler sleeve, etc. as called out in detail 6/LM502 with the T20 flagpoles to be provided by owner.
Question: Please clarify permit and fee responsibility, including local permits, utility / impact fees, fugitive-dust permits, and SWPPP-related fees.
Answer: DFCM is already working on permitting and connections for the utilities. Contractor will have some coordination with DFCM for permitting but DFCM will pay for utility connections and utility permit/impact fees. Required SWPPP and Fugitive Dust Permits and Fees will be the responsibility of the contractor.
Question: Please confirm the exact APWA edition applicable to the bid and construction.
Answer: The most recent edition published by the APWA Utah Chapter is the 2026 Edition. The 2026 Edition is applicable to the bid and construction, with the exception of work within public right-of-way or utility easements, in which you will need to comply with the requirements of the jurisdiction having authority.
Question: Please correct or confirm the inconsistent federal project identifier UT-16-05 versus UT-19-05.
Answer: Correct FAI # is UT-19-05. The UT-16-05 number on the Specifications Cover is a typographical error.
Question: Can you confirm that this project will require prevailing wages?
Answer: Yes, this project is subject to the requirements of Davis Bacon and will require prevailing wages and certified payroll as required.
Question: Can you confirm that this project will be a Buy America Build America?
Answer: Yes, this project will need to comply with the provision of Buy America Build America.
Contract Document Clarifications/Revisions:
Bid Schedule w/ Additional Detail: The VCGP Grant Requires additional detail of bidding amounts for Grant Applications and processing. As such, in addition to providing your bid amounts in the required locations on Bonfire/U3P, contractor shall fill out and submit the attached “DFCM Project #26360490 – Northern Utah Veterans Cemetery Bid Schedule.”
Construction Cost Estimate: The bid solicitation listed the Construction Cost Estimate as $12,000,000. The final total Construction Cost Estimate is $13,800,000.
Preplaced Lawn Crypts Bid Amount: The cost to supply and deliver the Pre-Placed Lawn Crypts is funded from a different funding source. Contractor shall provide a separate Bid Line Item for the Manufacture and Delivery of Pre-Placed Lawn Crypts.
$25,000 Allowance for Spring Water Mitigation at Maintenance Yard: The contractor shall include a $25,000 allowance in their bid to address mitigation of spring water near the location of the new Landscape Material Bins and Fuel Tanks. The Contractor will be required to include this allowance as a separate line item on their schedule of values for easy tracking during construction. The recent fire on the site exposed a manhole that was previously unknown. It is located right at the base of an existing tree that is to be removed as part of construction. The manhole contains some existing corrugated drain piping that appears to convey water from a spring source located upslope. Existing conditions and the presence, source, and extent of groundwater/spring water have not been verified.
No construction activities impacting this area shall commence until a field investigation has been completed and reviewed by the owner and engineer. The field investigation shall be coordinated with the owner and engineer and shall include, at a minimum, potholing and verifying the location, elevation, size, material, condition, and connectivity of all pipes entering and exiting the manhole, as well as documenting any observed groundwater or spring water conditions.
Following review of the field investigation results, the engineer will determine and provide direction for required mitigation measures. No work associated with this area shall proceed until the required mitigation measures have been identified and approved.
Mechanical/Plumbing Plan Revision – see attached Revised Sheets PB101 and PB601 containing the following revisions:
• Sheet PB101 – revision to Mop Sink at Admin Building.
• Sheet PB601 – Revision to Plumbing Fixture Schedule for Mop Sink/Mop Basin and the addition of Domestic Cold Water Demand Table.
Architectural Plan Revision – see attached Revised Sheets AB171and AC601 containing the following revisions:
• Sheet AC601 – Detail 9 on AC601 was updated to include an air barrier over ice and water barrier and over metal flashing. A note for high temperature ice and water barrier was also added, along with updated graphic.
• Sheet AB171 – A roof fence was added to AB171 to protect roof vents.
Attachments:
• DFCM Project #26360490 – Northern Utah Veterans Cemetery Bid Schedule
• CPT Data files in .csv format (CPT-1.csv, CPT-2.csv, CPT-3.csv) attached separate of this document.
• Revised Mechanical/Plumbing Sheets PB101 and PB601
• Revised Architectural Sheets AB171 and AC601
End Addendum
DFCM Project # 26360490 Northern Utah Veterans Cemetery – Bid Schedule
The VCGP Grant requires additional detail of bidding amounts. As such, in addition to providing your bid amounts in the required locations on Bonfire/U3P, contractor shall provide this bid schedule with the requested breakdown.
Pre-Placed Lawn Crypt Manufacture & Delivery
All Other Base Bid Work (minus the Manufacture & Delivery of Pre-Placed Lawn Crypts)
Total Base Bid Project Bid Amount (Crypt manufacture & deliver + All other Base Bid Work)
Add Alternate #1 – Security Camera System
AIR COMPRESSOR
FLAMMABLE STORAGE CABINET
SHOWER/RESTROOM
PARTS & TOOLS STORAGE
VEHICLE & EQUIPMENT STORAGE
HONOR GUARD
JAN
CLOSET
FOREMAN'S OFFICE
HALL
SERVICE BAY
BOOTS & LOCKERS
LAV
SS
KS
FD
FD
HB
NFHB
NFHB
TD
3 41 2
B
C
WC
UH-1
1/
2" ø
4" ø 4" ø
SHR-A
WH-1
TD
3"ø
WH-1
2 1/2"ø V UP
2 3 4 5
NFHB 6
FD
3/4"ø
FCO
1/ 2" ø
FD
FD
FD
7 2"ø
4"ø
1"ø
1 1/2"ø 3/4"ø
3/ 4" ø
1 1/2"ø
3/4"ø
1/ 2" ø
4"ø
2"ø
1/ 2" ø
1/
4" ø
1/ 2" ø
1/2"ø
1 1/2"ø
3/4"ø
3/4"ø
MOP
324 S. State St., Suite 400 Salt Lake City, UT 84111 www.lynkengineers.com
No. 14293880
J. ALEXANDER
BOSWELL
E
ED
P ROF E S S
ENG
I ONA L
IN
E
E R
S N
CI
L
S T A T E O F T A H U
REVISIONS:
STAMP:
SHEET TITLE:
NO
RT
HE
RN
U
TA
H
VE
TE
RA
NS
C
EM
ET
ER
Y
- P
HA
SE
S
OU
TH
A
DA
MS
A
VE
W
AS
HI
NG
TO
N
TE
RR
AC
E, U
TA
H
CONSULTANTS:
DFCM APPROVAL STAMP:
PREPARED FOR:
UTAH DIVISION OF FACILITIES
CONSTRUCTION & MANAGEMENT
CO
NS
TR
UC
TI
ON
D
OC
UM
EN
T
BI
D
SE
T
DATE:
DRAWN BY:
CHECKED BY:
JOB #:
FAI #:
DFCM #: 26360490
UT-19-05
U26-010
SHEET NO:
A
B
C
D
2 3 4 5 6
E
07/30/2026
8/
/2
4:
:5
PM
Au to de sk
D oc s:
-0
N
U
VC
/2 6-
N
U
VC
M ai nt en an ce B ui ld in g
-M ec ha ni ca l.
rv t
PB101
LEVEL 1 PLUMBING PLAN
MLA
CLT
30 JULY 2026
SCALE: 1/2" = 1'-0"PB101
LEVEL 1 PLUMBING PLAN1
SHEET KEYNOTES
1 NATURAL GAS METER BY LOCAL UTILITY.
INLET PRESSURE: 4 OZ
TOTAL DEMAND: 342 CFH
ADDITIONAL CAPACITY FOR FUTURE USE: 335 CFH
2 GAS FROM CIVIL. METER BY LOCAL UTILITY.
3 WATER LINE FROM CIVIL.
4 SANITARY SEWER TO CIVIL.
5 SAND OIL LINE TO CIVIL.
6 PROVIDE ISOLATION VALVE AT SERVICEABLE HEIGHT.
7 BALANCE FLOW RATE TO 1.75 GPM.
A.
B.
C.
D.
E.
F.
ALL DOMESTIC WATER PIPING TO BE COPPER. ALL HOT WATER AND HOT
WATER RECIRCULATING PIPING TO BE INSULATED WITH 1" UP TO 1-1/4"
PIPE AND 1-1/2" INSULATION FOR PIPING 1-1/2" AND LARGER. DOMESTIC
COLD WATER PIPING TO BE INSULATED WITH 1/2" UP TO 1-1/4" PIPING AND
1" INSULATION FOR PIPING 1-1/2" OR LARGER.
THE CONTRACTOR SHALL CLOSELY COORDINATE MECHANICAL AND
PLUMBING WITH ELECTRICAL, ARCHITECTURAL, AND BUILDING
STRUCTURE.
DISSIMILAR METAL PIPING CONNECTIONS SHALL HAVE DIELECTRIC
ISOLATORS.
ALL DOMESTIC WATER PIPING TO BE PRESSURE TESTED, CLEANED, AND
DISINFECTED. SEE SPECIFICATIONS.
BALL VALVES SHALL BE FULL PORT AND LEAD FREE. PROVIDE WITH
HANDLE/STEM EXTENSIONS FOR PROPER FUNCTION WHEN FULLY
INSULATED. EXTENSIONS TO BE SEALED AND VAPOR PROOF.
ALL PLUMBING PIPING TO BE LOCATED ON WARM SIDE OF BUILDING
ENVELOPE. ALL ROOF DRAIN PIPING (PRIMARY AND SECONDARY) TO BE
LOCATED IN BUILDING ENVELOPE AND TO BE FULLY INSULATED,
INCLUDING ANY ROOF DRAIN BOWLS.
G.
H.
I.
J.
K.
L.
M.
WATER HAMMER ARRESTORS SHALL BE SIZED AND INSTALLED PER
PLUMBING AND DRAINAGE INSTITUTE (STANDARD PDI-WH 201)
REQUIREMENTS IN ACCESSIBLE LOCATIONS ON THE COLD WATER AND
HOT WATER PIPING WHERE FLUSH VALVES OR QUICK CLOSING VALVES
ARE USED.
PROVIDE BALANCE REPORT OF DOMESTIC WATER RECIRCULATING
SYSTEM TO ENGINEER. PROVIDE P&T PORTS AND PRESSURE GAUGES
ON EACH SIDE OF RECIRCULATING PUMP. PROVIDE THERMOMETER ON
DISCHARGE SIDE OF PUMP.
PROVIDE A MARINE TOPSIDE BLACK PAINT ON ALL NEW GAS PIPING.
TEST WASTE AND VENT PIPING FOR LEAKAGE. SEE SPECIFICATIONS.
PIPING SHALL NOT BE SUPPORTED FROM THE ROOF DECK, JOIST
BRIDGING OR OTHER PIPES. HANG PIPES FROM BEAMS, JOIST OR
SUPPLEMENTARY STRUCTURAL MEMBERS. WHERE POSSIBLE INSTALL
ALL PIPING WITHIN 12" FROM SUPPORTING STRUCTURE.
WHERE JURISDICTION REQUIRES, THE CONTRACTOR IS RESPONSIBLE
FOR PROVIDING SEISMIC RESTRAINT. PROVIDE DESIGN DRAWINGS TO
AUTHORITY HAVING JURISDICTION AND MECHANICAL ENGINEER FOR
REVIEW.
PROVIDE PORTABLE PUMP (LITTLE GIANT UPSP-5 OR EQUAL) TO OWNER
FOR HYDRAULIC ELEVATOR SUMP. PROVIDE PLUG IN MOISTURE
SENSOR WITH AUDIBLE ALARM (FLOODMASTER RS-096 OR EQUAL). NOT
REQUIRED FOR TRACTION ELEVATORS.
PLUMBING GENERAL NOTES N.
O.
a.
b.
c.
d.
e.
ALL PIPING THROUGH A FOUNDATION WALL OR UNDER A FOOTING TO BE
PROVIDED WITH PIPE SLEEVE 2 PIPE SIZES LARGER THAN PIPE PASSING
THROUGH WALL OR UNDER FOOTING. SEAL WITH CAULK OR FOAM. PIPE
SLEEVE UNDER FOOTING TO BE A MINIMUM OF 2" BELOW FOOTING. PIPE
TO BE IRON AND EXTEND BEYOND THE WIDTH OF THE FOOTING AT A 45
DEGREE ON BOTH SIDES OF FOOTING.
PLUMBING PIPING SCHEDULE:
DOMESTIC WATER ABOVE GRADE= TYPE L COPPER - SOLDERED
DOMESTIC WATER BELOW GRADE= TYPE K COPPER - SOLDERED
ROOF DRAIN, WASTE & VENT ABOVE GRADE = CAST IRON -
HUBLESS COUPLINGS WITH HEAVY DUTY COUPLINGS
ROOF DRAIN, WASTE & VENT BELOW GRADE = DWV SOLID CORE
PVC - SOLVENT CEMENT
NATURAL GAS PIPING 2" AND SMALLER = SCHEDULE 40 BLACK
STEEL PIPE - THREADED
N
1 ADDENDUM #3 08/26/2026
METER
GAS FLOW
FROM MAIN
GROUND LEVEL
PLUG COCK
REGULATOR BYPASS "T"
UNISTRUT TYPE
BRACKET ASSEMBLY
IS RECOMMENDED
INTO PROTECTED
STRUCTURE
WALL
PROVIDE WITH SHUT
OFF/ISOLATION VALVE1.
NOTE:
COORDINATE WITH LOCAL GAS
UTILITY PROVIDER FOR
INSTALLATION
REQUIREMENTS.
ADJUSTABLE
STRAINER TILE FLOOR
TILE BED
30"x30" SQUARE 4 LBS. LEAD OR 16 OZ
COPPER FLASHING MEMBRANE
NO-HUB CONNECTION CAULKED CONNECTION
FLASHING COLLAR
FLOORSURE SEAL
SS3509
1.
2.
3.
NOTES:
TRAP GUARD NOT REQUIRED IN ROOMS WITH HOSE BIB(S).
THIS INCLUDES POOL ROOMS, BOILER ROOM, PUMP ROOM & UTILITY ROOM.
USE DEEP SEAL P-TRAP IN RETURN AIR CHASE IN COMPETITION ROOM.
LV
LV
DHWR
DCW
DCW
DHW
FLOW SETTER
SINK CONNECTIONS SIMILAR
EQUIPMENT
FULL SIZE CAPPED
INSPECTION TEE
GAS COCK
DIRT LEG
RUBBER
GROMMET
RUN GAS LINE FULL
SIZE TO EQUIPMENT
FLEXIBLE PIPING
GAS LINE - SEE
PLANS FOR SIZE AND
CONTINUATION
WATER HEATER LOCATED
ABOVE MOP SINK
SEE
PLUMBING
DRAWINGS
FOR SIZE
"RPZ-1" BFP (WATTS
LF009 OR EQUAL)
SPILL DRAIN
OVER MOP
SINK WITH
APPROVED
AIR GAP
PRESSURE
GAUGE 0-100
PSI RANGE
UNION (TYP)
COMBINATION PRESSURE REDUCING VALVE
AND STRAINER SET DISCHARGE AT 60 PSIG
BALL VALVE (TYP)
WALL
1 1/2" WATER
SUPPLY FROM
STREET
MOP SINK
RUN DRAIN TO
SERVICE SINK
3/4"
GAS FIRED
INSTANTANIOUS
WATER HEATER
UNION (TYP)
GAS SUPPLY
DOMESTIC COLD WATER SUPPLY
DOMESTIC HOT WATER SUPPLY TO FIXTURES
PRESSURE AND TEMPERATURE RELIEF VALVE
3/4" DRAIN VALVE
BALANCING
VALVE
REDUCING
COUPLING
SPRING LOADED
CHECK VALVE
MOTOR
INLINE CIRCULATING
PUMP
BALL VALVE
(TYP)
T&P VALVE
(TYP)
FLOW
324 S. State St., Suite 400 Salt Lake City, UT 84111 www.lynkengineers.com
No. 14293880
J. ALEXANDER
BOSWELL
E
ED
P ROF E S S
ENG
I ONA L
IN
E
E R
S N
CI
L
S T A T E O F T A H U
REVISIONS:
STAMP:
SHEET TITLE:
NO
RT
HE
RN
U
TA
H
VE
TE
RA
NS
C
EM
ET
ER
Y
- P
HA
SE
S
OU
TH
A
DA
MS
A
VE
W
AS
HI
NG
TO
N
TE
RR
AC
E, U
TA
H
CONSULTANTS:
DFCM APPROVAL STAMP:
PREPARED FOR:
UTAH DIVISION OF FACILITIES
CONSTRUCTION & MANAGEMENT
CO
NS
TR
UC
TI
ON
D
OC
UM
EN
T
BI
D
SE
T
DATE:
DRAWN BY:
CHECKED BY:
JOB #:
FAI #:
DFCM #: 26360490
UT-19-05
U26-010
SHEET NO:
A
B
C
D
2 3 4 5 6
E
07/30/2026
8/
/2
4:
:5
PM
Au to de sk
D oc s:
-0
N
U
VC
/2 6-
N
U
VC
M ai nt en an ce B ui ld in g
-M ec ha ni ca l.
rv t
PB601
PLUMBING SCHEDULES
MLA
CLT
30 JULY 2026
REFER TO PLUMBING SPECIFICATIONS FOR COMPLETE FIXTURE COMPONENTS
PLUMBING FIXTURE SCHEDULE
LABEL
IMAGE
DESCRIPTION
PIPE SIZE
MANUFACTURER & MODEL REMARKSFIXTURE ACCESSORY WASTE TRAP VENT CW HW
FCO FLOOR CLEANOUT 0" 0" 0" 0" 0" FIXTURE: ZURN Z1400 SERIES SIZE TO MATCH PIPE BEING
SERVED
FD FLOOR DRAIN 2" 2" 2" 0" 0" FIXTURE: ZURN Z415-BZ1
TRAP SEAL: RECTORSEAL
SURESEAL
TRAP SEAL TO MATCH FD
SIZE
HB HOSE BIB 0" 0" 0" 1/2" 0" FIXTURE: JAY R. SMITH s5672
KS KITCHEN SINK 2" 1 1/2" 1 1/2" 1/2" 1/2" FIXTURE: K-6661
FAUCET: K-22065
DISPOSER: INSINKERATOR BADGER 5
TMV: BRADLEY S59-4100
SET TMV AT 110°F.
LAV OVAL LAVATORY 2" 1 1/2" 1 1/2" 1/2" 1/2" FIXTURE: K-2211
FAUCET: K-15240
INSULATION: TRUEBRO LAVGUARD 2
TMV: WEBSTONE H-77211W-TG
SET TMV AT 110°F
MOP SERVICE SINK
MOP BASIN
3" 3" 1 1/2" 3/8" 3/8" FIXTURE: MUSTEE MODEL 63M
FAUCET: MUSTEE 63.600A
PROVIDE WITH HOSE AND
HOSE HOLDER, MOP
HANGER, BUMPER GUARDS,
AND WALL GUARDS.
NFHB NON-FREEZE HOSE BIB 0" 0" 0" 1/2" 0" FIXTURE: JAY R. SMITH 5673
SHR-A SHOWER (ACCESSIBLE) 2" "FD" 1 1/2" 1/2" 1/2" FIXTURE: SYMMONS 1-25VT-T736 MOUNT FOR ADA
REQUIREMENTS
SS SERVICE SINK 2" 1 1/2" 1 1/2" 1/2" 1/2" FIXTURE: HAWS 7661
FAUCET: HAWS 7661
TMV: BRADLEY S59-4100
SET TMV AT 110°F.
TD TRENCH DRAIN 2" 2" 0" 0" 0" FIXTURE: JAY R. SMITH 9870-405-GM
WC WATER CLOSET 4" 3" 2" 1 1/4" 0" FIXTURE: K-96059
FLUSH VALVE: K-76322
SCALE: NTS1 GAS METER DETAIL
SCALE: NTS6 FLOOR DRAIN
SCALE: NTS3 LAVATORY DOMESTIC WATER CONNECTION
SCALE: NTS4 GAS PIPE DETAIL
LOCHINVAR
AO SMITH
BRADFORD WHITE
RHEEM
STATE
BOCK
(1) PROVIDE WITH CONCENTRIC VENT KIT.
(2) PROVIDE WITH EXPANSION TANK THERM-X-TROL ST-5.
(3) PROVIDE WITH UPPER AND LOWER SEISMIC STRAPS WITH TWO 5/16" LAG SCREWS HAVING 2" OF EMBED AT EACH CONNECTION LOCATION.
(4) WATER HEATER TO BE ULTRA LOW NOX.
(5) ROUTE RELIEF VALVE PIPING TO MOP SINK BELOW.
(6) PROVIDE RECIRCULATION PUMP.
ACCEPTABLE MANUFACTURERS: REMARKS:
WATER HEATER (GAS)
LABEL TYPE
RECOVERY
GPH
@ 100° ΔT
GAS INPUT
(BTUH)
EFFICIENCY
(UEF)
ELECTRICAL OPERATING
WEIGHT
(LBS) MANUFACTURER MODEL REMARKSVOLTS PHASE Hz FLA
WH-1 TANKLESS 4 199,000 0.93 120 1 60 1.0 74 A.O. SMITH ACT-199I-N ALL
2021 INTERNATIONAL FUEL GAS CODE
BASIS OF DESIGN NOTES:
TOTAL: 342 X 1 1/2"
WH-1 1 199,000 224 224 X 3/4"
UH-1 1 45,000 50 50 X 1/2"
F-1 1 60,000 68 68 X 1/2"
2 PSIG 0.5 PSIG
EQUIPMENT QUANTITY
SEA LEVEL FUEL
GAS INPUT
CAPACITY
(BTUH)
JOB SITE FUEL
GAS
REQUIREMENTS
(CFH)
TOTAL
FUEL GAS
CAPACITY
(CFH)
BRANCH PIPE SIZES
(INCHES)
NATURAL GAS REQUIREMENTS
Image
SCALE: NTS7 PRV STATION (AT MOP SINK) DETAIL
SCALE: NTS2 INSTANTANEOUS WATER HEATER (GAS FIRED)
SCALE: 1/8" = 1'-0"5 PUMP - INLINE DETAIL
PIPE VELOCITY (FEET / SECOND): 7
2024 INTERNATIONAL PLUMBING CODE - FIGURE E103.3(5) PIPE FRICTION (PSI / 100 FT): 6
PIPE SIZE (WATER SUPPLY TO BUILDING): 1 1/2"
2021 INTERNATIONAL PLUMBING CODE - TABLE E103.3(3) ESTIMATED DEMAND (GPM): 42
DOMESTIC COLD WATER DEMAND
EQUIPMENT OCCUPANCY
TYPE OF SUPPLY
CONTROL QUANTITY
COMBINED
WATER SUPPLY
FIXTURE UNITS
(WSFU)
TOTAL WATER
SUPPLY
FIXTURE UNITS
(WSFU)
HOSE BIB PUBLIC FAUCET 1 0.7 0.7
LAVATORY PUBLIC FAUCET 1 2 2
NON-FREEZE HOSE BIB PUBLIC FAUCET 3 0.7 2.1
SERVICE SINK OFFICES, ETC. FAUCET 1 3 3
SHOWER HEAD PRIVATE MIXING VALVE 1 1.4 1.4
SINK HOTEL,
RESTAURANT
FAUCET 2 3 6
WATER CLOSET FLUSH
VALVE
PUBLIC FLUSH VALVE 1 10 10
TOTAL 10 25.2
1 ADDENDUM #3 08/26/2026
GENERAL NOTES
A. GENERAL CONTRACTOR SHALL VERIFY ALL CONDITIONS, DIMENSIONS, AND
ASSEMBLIES PRIOR TO CONSTRUCTION. REPORT ANY SIGNIFICANT
DISCREPANCIES TO THE ARCHITECT.
B. MINIMUM ROOF CLASSIFICATION TO BE AS NOTED ON THE CODE ANALYSIS.
C. COORDINATE INSTALLATION OF ALL "AFTER CONTRACT" ASSEMBLIES PRIOR TO
CONSTRUCTION OF ADJOINING OR RELATED STRUCTURES.
D. MINIMUM ROOF SLOPE TO BE 1/4" PER FOOT.
E. INSULATE ENTIRE ROOF WITH R-30 POLYISOCYANURATE ABOVE ROOF
DECKING.
F. FLASH AND COUNTER FLASH ALL ROOF PENETRATIONS PER SINGLE-PLY
MANUFACTURER'S RECOMMENDATIONS.
G. TIE PRIMARY ROOF DRAINS INTO SITE STORM DRAINAGE SYSTEM. TIE
SECONDARY ROOF DRAINS THROUGH BRASS SCUPPERS.
H. ALL MECHANICAL UNITS AND ROOF PENETRATIONS MAY NOT BE SHOWN.
REFER TO ENGINEERING SHEETS FOR ALL REQUIRED MECHANICAL UNITS AND
ROOF PENETRATIONS. PROVIDE FLASHING, CRICKETS, AND REGLETS AT EACH
UNIT. CRICKETS TO SLOPE 1/4" PER FOOT MINIMUM. SEE TYPICAL ROOF
DETAILS.
I. MECHANICAL CURBS TO BE 8" MINIMUM ABOVE NEAREST HORIZONTAL OR
SLOPED ROOF SURFACE.
J. SLEEPER INSTALLATION NOT PERMITTED AT MECHANICAL UNITS. PROVIDE
FULL MECHANICAL CURB DETAILING.
K. DO NOT SCALE DRAWINGS.
A A
C C
B B
D D
11" 10" 1'-1" 21'-7" 17'-10" 1'-6" 10'-5" 1'-8"
1'-9" 1'-1" 21'-7" 17'-10" 11'-11" 1'-8"
55'-11"
55'-11"
23.0323.03
23.03
07.02 07.02
07.02 07.02
REVISIONS:
STAMP:
SHEET TITLE:
N O
R T
H E
R N
U T
A H
V E
T E
R A
N S
C E
M E
T E
R Y
P
H A
S E
S
O U
T H
A D
A M
S A
V E
W A
S H
IN
G
T O
N T
E R
R A
C E
U
T A
H
CONSULTANTS:
DFCM APPROVAL STAMP:
PREPARED FOR:
UTAH DIVISION OF FACILITIES
CONSTRUCTION & MANAGEMENT
C O
N S
T R
U C
T
IO
N D
O C
U M
E N
T B
ID
S
E T
DATE:
DRAWN BY:
CHECKED BY:
JOB #:
FAI #:
DFCM #: 26360490
UT-19-05
U26-010
SHEET NO:
AB171
ROOF PLAN
MLA
CLT
30 JULY 2026
KEYNOTES
07.02 SNOW FENCE REQUIRED TO BE INSTALLED ABOVE HIGH BAY
DOORS PER MANUFACTURER SPECIFICATIONS.
23.03 MECHANICAL EQUIPMENT, SEE MECHANICAL.
N
SCALE: 1/2" = 1'-0"AB171
ROOF PLAN
1 ADDENDUM #01 8/18/2026
2 ADDENDUM #03 8/25/2026
S
TA
TE OF UTAH
L
IC
ENSED ARCHIT
EC
T
CHRISTOPHER
L.
THOMPSON
8/25/2026
GENERAL NOTES
A. THE CONTRACTOR IS TO VERIFY THE DIMENSIONS OF ALL OPENINGS PRIOR TO
THE FABRICATION OF ALL DOORS AND FRAMES.
B. DUE TO MULTIPLE USE, SOME OF THE DETAILS REFERRED TO ON THE DOOR
SCHEDULE ARE REVERSED OR TURNED FROM THE DIRECTION SHOWN ON THE
FLOOR PLANS. THE INTENT OF THE DETAILS IS TO BE FOLLOWED. CONSULT
THE ARCHITECT WHEN QUESTIONS ARISE.
C. ALL EXIT ACCESS DOORS AND EXIT DOORS SHALL BE OPENABLE FROM THE
INSIDE WITHOUT THE USE OF A KEY, SPECIAL KNOWLEDGE, OR EFFORT. USE
OF MANUAL FLUSH BOLTS, EDGE BOLTS, TOP OR BOTTOM BOLTS, ETC., IS
PROHIBITED.
D. DOOR CLOSERS SHALL BE ADJUSTED SO THAT FROM AN OPEN POSITION OF 90
DEGREES, THE TIME REQUIRED TO MOVE THE DOOR TO AN OPEN POSITION OF
12 DEGREES WILL BE 5 SECONDS MINIMUM.
E. THE BOTTOM 10" OF ALL DOORS EXCEPT AUTOMATIC DOORS, POWER ASSISTED
DOORS, AND SLIDING DOORS SHALL HAVE A SMOOTH UNINTERRUPTED
SURFACE TO ALLOW THE DOOR TO BE OPENED BY A WHEELCHAIR FOOTREST
WITHOUT CREATING A TRAP OR HAZARDOUS CONDITION. WHEN NARROW
STILE AND RAIL DOORS ARE USED, A 10" MINIMUM, SMOOTH PANEL,
EXTENDING THE FULL WIDTH OF THE DOOR, SHALL BE INSTALLED ON THE
PUSH SIDE(S) OF THE DOOR WHICH ALLOW THE DOOR TO BE OPENED BY A
WHEELCHAIR FOOTREST WITHOUT CREATING A TRAP OR HAZARDOUS
CONDITION. CAVITIES CREATED BY KICK PLATES SHALL BE CAPPED.
F. ALL DOOR LOCKSETS AND PANIC DEVICES SHALL BE ADA COMPLIANT LEVER
TYPE.
G. CAULK HEAD, JAMBS, AND SILLS OF ALL DOORS AND WINDOWS WITH SEALANT
CONTINUOUSLY APPLIED TO BOTH SIDES OF THE FRAMES.
H. COORDINATE KEYING TYPE AND SCHEDULE WITH OWNER.
I. ALL DOOR CLOSURES TO BE SET IN ACCORDANCE WITH THE ADA REDUCED
OPENING FORCE REQUIREMENTS.
J. SEE SPECIFICATIONS FOR DOOR HARDWARE. GLAZING OF CURTAIN WALL AND
SUPPORT AS PER MANUFACTURER RECOMMENDATIONS. COORDINATE LOADS
WITH STRUCTURAL PRIOR TO STEEL FABRICATION.
GLAZING SCHEDULE
1/2" INSULATED TEMPERED GLASS1
2" 3'-0" 3'-0" 2"
6'-4"
FINISHED
FLOOR A B
A
2" 6" 2'-6" 6"6" 2'-6" 6" 2"
7'-4"
AC601
AC601
DOOR CLOSER
4" MAXIMUM PROJECTION
INTO CLEAR WIDTH
WHERE VISION LIGHTS ARE
PROVIDED, LIGHTS SHOULD
EXTEND TO WITHIN 43" OF
FINISHED FLOOR
DOOR HARDWARE TO BE
LOCATED BETWEEN 34" AND
40" ABOVE FINISHED FLOOR
BOTTOM 10" OF DOOR
SURFACE TO BE SMOOTH
(N O
P R O
J E C
T
IO
N S P
E R M
IT
T E D
32"
(M
INIM
UM CLE
AR W
IDTH)
90 DEGREES
NOTE: HARDWARE TO BE OPERATED WITH ONE HAND, WITHOUT TIGHT
GRASPING, PINCHING OR TWISTING OF THE WRIST. THRESHOLDS ARE LIMITED
TO 1/2" MAXIMUM HEIGHT. INTERIOR DOORS, OTHER THAN FIRE DOORS,
SHOULD BE ABLE TO BE OPERATED WITH 5 POUNDS OF FORCE. EXTERIOR DOOR
AND FIRE DOORS ARE REGULATED BY THE AUTHORITY HAVING JURISDICTION.
REFER TO ANSI STANDARD A117.1 FOR APPROACH REQUIREMENTS.
FINISHED
FLOOR A-C B-C C-C
101-C
2"
1'-10"
2"
4"
2"
7'-0"
2"
4"
2"
7'-0"
2"
4"
2"
7'-0"
2"
4"
2"
1'-11"
1"
27'-8"
SEE DOOR
TYPES
SEE DOOR
TYPES
SEE DOOR
TYPES
1 1 1 1 1
AC601
AC601
05.02 05.02 05.02 05.02
7'-0"
108-C
SEE DOOR
TYPES
SEE DOOR
TYPES
SEE DOOR
TYPES
2"
1'-10"
2" 4"
2"
7'-0"
2"
4"
2"
7'-0"
2"
4"
2"
7'-0"
2"
4"
2"
1'-10"
2"
27'-8"
AC601
AC601
1 1 1 1 1
05.02 05.02 05.02 05.02
2"3'-3"2"
3'-7"
AC601
AC601
D-CD-CD-C
D-CD-CD-C
2" 8'-5" 2" 1'-3" 2" 8'-5" 2" 1'-3" 2" 8'-5" 2"
28'-10"
AC601
AC601
AC601
A
SCALE: 3/4" = 1'-0"
WALL TYPE
B
SCALE: 3/4" = 1'-0"
WALL TYPE
C
SCALE: 3/4" = 1'-0"
WALL TYPE
5/8" TYPE 'X' GYPSUM BOARD - PAINTED
2X6 WOOD STUDS @ 16" O.C.
5/8" EXTERIOR GYPSUM SHEATHING
LIQUID APPLIED AIR/WEATHER BARRIER
1" AIR GAP
R-20 BATT INSULATION WITH 6 MIL
VAPOR RETARDER TO WARM SIDE
ONE HOUR RATED
UL U419
TO DECK ABOVE
1 1/2" EPS CONTINUOUS INSULATION
BOARD. ADHERED TO EXTERIOR
SHEATHING WITH EPOXY ADHESIVE
VERTICALLY APPLIED
BRICK VENEER
SEE EXTERIOR ELEVATIONS
5/8" TYPE 'X' GYPSUM BOARD - PAINTED
2X6 WOOD STUDS @ 16" O.C.
5/8" EXTERIOR GYPSUM SHEATHING
LIQUID APPLIED AIR/WEATHER BARRIER
DRYVIT FINISH SYSTEM - 3/8" FIBER
REINFORCED EIFS SYSTEM
R-20 BATT INSULATION WITH 6 MIL
VAPOR RETARDER TO WARM SIDE
1 1/2" EPS CONTINUOUS INSULATION
BOARD. ADHERED TO EXTERIOR
SHEATHING WITH EPOXY ADHESIVE
VERTICALLY APPLIED
5/8" TYPE 'X' GYPSUM BOARD - PAINTED
2X6 WOOD STUDS @ 16" O.C.
ONE HOUR RATED
UL U419
TO DECK ABOVE
R-20 BATT INSULATION WITH 6 MIL
VAPOR RETARDER TO WARM SIDE
DOOR NOTES
1. ALUMINUM MULLION
2. ALUMINUM AND GLASS DOOR
3. HOLLOW METAL DOOR FRAME
4. HOLLOW METAL DOOR
SCHEDULED WALL FINISH
WINDOW AS PER TYPES
SHIM, BACKER ROD, AND
CONTINUOUS SEALANT AS
REQUIRED (EXTERIOR)
METAL FLASHING
VAPOR BARRIER AS PER WALL
TYPES
SHIM, BACKER ROD, AND
CONTINUOUS CAULK AS
REQUIRED (INTERIOR)
HIGH TEMPERATURE ICE AND
WATER BARRIER
ROOF SHEATHING AS
REQUIRED
ROOF FINISH PER PLANS
METAL FLASHING
STRUCTURAL PER PLANS
BLOCKING
AIR BARRIER OVER ICE AND
WATER BARRIER AND ALSO OVER
METAL FLASHING
SCHEDULED WALL TYPE
HEADER AS PER STRUCTURAL
CONTINUOUS CAULK BOTH
SIDES
PAINTED HOLLOW METAL
FRAME
DOOR AS PER SCHEDULE
SCHEDULED WALL TYPE
WOOD STUD JAMB AS
REQUIRED
CONTINUOUS CAULK BOTH
SIDES
PAINTED HOLLOW METAL
FRAME
DOOR AS PER SCHEDULE
2"
SCHEDULED WALL FINISH
WINDOW AS PER TYPES
SHIM, BACKER ROD, AND
CONTINUOUS SEALANT AS
REQUIRED (EXTERIOR)
VAPOR BARRIER AS PER WALL
TYPES
WOOD STUD JAMB AS
REQUIRED
SHIM, BACKER ROD, AND
CONTINUOUS CAULK AS
REQUIRED (INTERIOR)
WEATHER BARRIER AS PER
WALL TYPES
SCHEDULED WALL FINISH
WINDOW AS PER TYPES
SHIM, BACKER ROD, AND
CONTINUOUS SEALANT AS
REQUIRED (EXTERIOR)
METAL FLASHING AND
COUNTER FLASHING AS
REQUIRED
VAPOR BARRIER AS PER WALL
TYPES
HEADER AS PER STRUCTURAL
SHIM, BACKER ROD, AND
CONTINUOUS CAULK AS
REQUIRED (INTERIOR)
WEATHER BARRIER AS PER
WALL TYPES
SCALE: 3/16" = 1'-0"AC601
ACCESSIBLE DOOR
DOOR SCHEDULE
MARK TYPE
DOOR SIZE MATERIAL
HARDWARE RATING COMMENTSWIDTH HEIGHT DOOR FRAME
LEVEL 1 FLOOR
101-C A 7'-0" 10'-0" GLASS/ALUM ALUM 1.0 0
FLOOR CLOSER, HOLD OPEN WITH POSITIVE DEAD STOP. VERTICAL PULLS WITH PUSH BAR. REFER TO
NOTES FROM SPENCER
102-C A 7'-0" 10'-0" GLASS/ALUM ALUM 1.0 0
FLOOR CLOSER, HOLD OPEN WITH POSITIVE DEAD STOP. VERTICAL PULLS WITH PUSH BAR. REFER TO
NOTES FROM SPENCER
103-C A 7'-0" 10'-0" GLASS/ALUM ALUM 1.0 0
FLOOR CLOSER, HOLD OPEN WITH POSITIVE DEAD STOP. VERTICAL PULLS WITH PUSH BAR. REFER TO
NOTES FROM SPENCER
104-C B 6'-0" 8'-0" HM HM 2.0 0 ACTIVE - INACTIVE LEAF, HOLD OPEN, DOOR SEALS, DOOR SWEEP, THRESHOLD
105-C B 6'-0" 8'-0" HM HM 2.0 0 ACTIVE - INACTIVE LEAF, HOLD OPEN, DOOR SEALS, DOOR SWEEP, THRESHOLD
106-C A 7'-0" 10'-0" GLASS/ALUM ALUM 1.0 0
FLOOR CLOSER, HOLD OPEN WITH POSITIVE DEAD STOP. VERTICAL PULLS WITH PUSH BAR. REFER TO
NOTES FROM SPENCER
107-C A 7'-0" 10'-0" GLASS/ALUM ALUM 1.0 0
FLOOR CLOSER, HOLD OPEN WITH POSITIVE DEAD STOP. VERTICAL PULLS WITH PUSH BAR. REFER TO
NOTES FROM SPENCER
108-C A 7'-0" 10'-0" GLASS/ALUM ALUM 1.0 0
FLOOR CLOSER, HOLD OPEN WITH POSITIVE DEAD STOP. VERTICAL PULLS WITH PUSH BAR. REFER TO
NOTES FROM SPENCER
REVISIONS:
STAMP:
SHEET TITLE:
N O
R T
H E
R N
U T
A H
V E
T E
R A
N S
C E
M E
T E
R Y
P
H A
S E
S
O U
T H
A D
A M
S A
V E
W A
S H
IN
G
T O
N T
E R
R A
C E
U
T A
H
CONSULTANTS:
DFCM APPROVAL STAMP:
PREPARED FOR:
UTAH DIVISION OF FACILITIES
CONSTRUCTION & MANAGEMENT
C O
N S
T R
U C
T
IO
N D
O C
U M
E N
T B
ID
S
E T
DATE:
DRAWN BY:
CHECKED BY:
JOB #:
FAI #:
DFCM #: 26360490
UT-19-05
U26-010
SHEET NO:
AC601
DOOR, WINDOWS & WALL
TYPES
MLA
CLT
30 JULY 2026
SCALE: 1 1/2" = 1'-0"AC601
H/M DOOR HEAD DETAIL
SCALE: 1 1/2" = 1'-0"AC601
H/M DOOR JAMB DETAIL
SCALE: 1 1/2" = 1'-0"AC601
ALUMINUM WINDOW HEAD DETAIL
SCALE: 1 1/2" = 1'-0"AC601
ALUMINUM WINDOW JAMB DETAIL
SCALE: 1 1/2" = 1'-0"AC601
ALUMINUM WINDOW SILL DETAIL
KEYNOTES
05.02 STRUCTURAL HSS MEMBER. SEE STRUCTURAL DRAWINGS FOR
SIZE AND CONNECTIONS
SCALE:
A601 1/4" = 1'-0"
DOOR TYPES
SCALE:
A601 1/4" = 1'-0"
WINDOW TYPES
SCALE: 3/4" = 1'-0"
WALL TYPES WS - BUILDING C
ADDENDUM #01 8/18/20261
2 ADDENDUM #03 8/25/2026
S
TA
TE OF UTAH
L
IC
ENSED ARCHIT
EC
T
CHRISTOPHER
L.
THOMPSON
8/25/2026