This document outlines the technical requirements for a solicitation seeking proposals for powered systems furniture, demountable architectural wall systems, and freestanding office furniture to be installed at a facility of the Department of Transportation's Federal Aviation Administration. Key requirements include powered and unpowered systems furniture in various configurations, architectural wall panels with a variety of finish options, adjustable-height desks, storage cabinets, tables, seating, and related accessories. Proposed products must meet specifications for construction, dimensions, finishes, electrical systems, accessibility, and warranties. The solicitation number is 6973GH-22-Q-00001 and proposals are due based on a deadline not specified in this document. Award is to be determined.

View the file

Other files for this federal contract opportunity

Show all 14

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Name of Of f eror: Technical Ev aluation 1

Technical Requirements Ev aluation: WO#14-004363 BMB Renov ation Furniture N/A Not Acceptable Acceptable Comments

1. GENERAL REQUIREMENTS: N/A

1.1. General. Furniture components shall have similar

construction and appearance, and ability to be integrated in the workspace.

1.2. Accessibil ity. All components and design shall meet

ADA and ABA (UFAS) guidelines.

1.3. ANSI/BIFMA - All furniture components shall comply

with the applicable ANSI/BIFMA Standards.

1.4. Product Brochure. A manufacturer’s brochure(s) with

color photographs of ALL the proposed furniture products shall be provided with bid package.

1.5. Product Specifications. A manufacturer’s detailed

product specification to determine compliance with FAA specifications shall be provided with bid package.

1.6. Warranty. A manufacturer’s minimum 10-year product

warranty (excluding fabrics and lighting) shall be provided with bid package.

1.7. Availabil ity. A manufacturer’s written guarantee of

availabil ity of components compatible with the original installation for a period of not less than five (5) years shall be provided with bid package.

1.8. Environmental Aspects. Provide manufacturer’s

information with bid package:

Env ironmental Aspects are not ev aluated on "quantity " of content, the intent is to approv e manuf acturer's that prov ide supporting documentation of sustainable & healthy manuf acturing practices.

1.8.1. Recycled Content. Amount of recycled content.

1.8.2. Recyclable. Amount of post-consumer recyclable

materials.

1.8.3. Air Quality Certification. Emission standards for

off-gassing of product components.

1.8.4. LEED Eligibil ity. Identification of LEED eligible

products.

Name of Ev aluator: Date:

Name of Of f eror: Technical Ev aluation 2

Renov ation Furniture N/A Not Acceptable Acceptable Comments

1.9. Product Colors. Furniture Contractor shall select

products that provide the following minimum color choices.

Provide samples with bid package.

1.9.1. Systems Furniture, Benching systems, & Private

Office Furniture:

1.9.1.1. Trim Colors – minimum five (5), pricing

shall be based on metall ic finishes

1.9.1.2. Laminate Colors – minimum six (6)

solids and six (6) wood-grains with matching wood grain PVC or ABS plastic edge

1.9.1.3. Overhead Cabinet Glazing – back

painted glass with a minimum two (2) colors.

1.9.1.4. Fabric Tiles - minimum five (5) patterns

with six (6) colors, pricing shall be based on Grade 1 fabrics.

1.9.1.5. Storage Seat Cushion- minimum of

five (5) patterns with six (6) colors, pricing shall be based on Grade 4 fabrics.

1.9.2. Architectural Wall System:

1.9.2.1. Trim Colors – minimum five (5), pricing

shall be based on metall ic finishes

1.9.2.2. Metal Skins- minimum of six (6) colors

1.9.2.3. Glazing – Clear, Frosted Glass or back

painted glass with a minimum two (2)

1.9.3. Banquette Seating & Lounge furniture

1.9.3.1. Laminate colors – minimum six (6)

woodgrains with matching PVC or ABS plastic edge

1.9.3.2. Wood Veneer – minimum six (6)

woodgrains

1.9.3.3. Upholstery – minimum five (5) patterns

with six (6) colors, pricing shall be based on Grades

Name of Of f eror: Technical Ev aluation 3

Renov ation Furniture N/A Not Acceptable Acceptable Comments

POWERED SYSTEM FURNITURE: Typicals

“2A, 2AS, 2B, 3A, 4AAS, 4BB, 4BBS, 6A, 6AA,

6AB, & 6BB & K” N/A

2. SYSTEMS FURN - PANEL FRAMES, PANEL FACES, &

PANEL INSERTS:

2.1. Product Quality & Aesthetics: Steel frame (factory baked-enamel finish) with ti led acoustical panel appearance.

2.2. Dimensions. Panels shall be available in +/- 66” high

and widths capable of configuring typicals in the space provided. Panel widths must be available in 6” increments between the widths of 24” and 60”.

2.3. Panel Thickness. Frames (with panel faces attached)

shall be 3 inches thick.

2.4. Panel Door. Doors shall be surface mount, glazed

sliding door 36” wide x +/- 66” tall doors shall be prov ided as shown on the Typical “2AS” Door frame shall match panel frame finish.

2.5. Panel Face. Panel faces shall be removable from the

frame & shall be TILED and have a minimum of two (2) ti les per panel frame.

2.5.1. Fabric Covered Tackable Acoustic Tiles: All fabric

panel faces shall be 100% synthetic fabric, have a Class “A” fire rating and be tackable.

2.5.2. Glazed. Stack-on style, center mount frameless

glazed panel +/- 12” high.

2.6. Component Mounting. Panel based systems shall

provide for the mounting of components at varying heights on both sides of the panel

2.6.1. Accessories.

2.6.1.1. Marker Board. Each work station shall

have a minimum of one 36X48 glazed dry erase board panel skins

Name of Of f eror: Technical Ev aluation 4

Renov ation Furniture N/A Not Acceptable Acceptable Comments

2.6.1.2. Tool Rail Panels. Tool rails and

compatible tool rail components must be available in standard product offering. Each typical work station requiring tool rails shall have a minimum of 12” minimum height tool rail installed above work

2.6.1.3. Tool Rail Accessories.

2.6.1.3.1. Display Tray Each work station

shall be provided with one tool rail mounted display tray.

2.6.1.3.2. Sorting Tray. Each work station

shall be provided with one tool rail mounted

2.7. Leveling and alignment. The system shall include

leveling guides to compensate for uneven floors. A minimum of .8 inches (20mm) adjustment range is required.

3. SYSTEMS FURN - POWER AND DATA DISTRIBUTION: N/A

3.1.1. Base Feed: Power & Data must be capable of

entering the furniture by the following methods:

3.1.1.1.1. Power & Data feeds may be

through separate junction boxes in wall located behind panels. Note: panels against wall shall be omitted.

3.1.1.1.2. Power & Data Feeds may be

through separate junction boxes located in

3.1.1.1.3. Power & Data feeds may be

through systems furniture furnished power/data poles. Note: power & data may not be run through a shared pole unless it is a divided and properly shielded power pole.

3.1.2. Distribution:

Name of Of f eror: Technical Ev aluation 5

Renov ation Furniture N/A Not Acceptable Acceptable Comments

3.1.2.1. Power and data must be separated by a

minimum of 24” at all points within the panel and feeds. The power and data cables shall NOT cross each other. NOTE: Power wire harnesses that are constructed of shielded flexible metal conduit are not required to maintain 24” separation

3.1.3. Power System. Power/Data panels shall include

an electrical system that is UL rated and meets all current National Electrical Code (NFPA 70) requirements. A minimum 8-wire, 3-circuit system (with minimum 20-amp 125 volts per circuit capacity) and minimum #12 AWG wire size shall be used. NOTE: 10 wire, 4 circuit system may be substituted, prov ided separate neutrals are prov ided for each circuit.

3.1.3.1. The power wiring system must provide

a separate and unique neutral conductor per circuit (i.e.: 3 circuits, 3 neutrals, and 2 grounds

3.1.3.2. Duplex receptacles shall be provided as

shown on the typical. Power outlets shall be 20 amps duplex (NEMA 5-20R).

3.1.3.3. The wiring harness system shall be

enclosed in flexible metal conduit.

3.1.4. Data Cable Management. Power/Data panels

shall have a data channel that is properly separated OR shielded from electrical sources. Data channels shall be accessible without remov ing panel hung components.

Panels shall offer the following capacities for routing data cables.

3.1.4.1. Furniture vendors shall provide flush

mounted faceplates, bezel and blank covers capable of accepting standard Aeronautical Center data receptacles.

Name of Of f eror: Technical Ev aluation 6

Renov ation Furniture N/A Not Acceptable Acceptable Comments

3.1.4.1.1. Knockout plates in the panel face

shall be capable of providing a minimum of 3 potential jacks per workstation. Data faceplates must be capable of three (3) RJ45 Systimax, Part # MGS400BH-112 (ORANGE) at each location shown

4. SYSTEMS FURN - PANEL HUNG WORK SURFACES: N/A

4.1. Construction. Shall be a minimum of 1” thick, 40-50#

density particle board with a high-pressure laminate.

4.2. Dimensions. The system shall include work surface

depths of 24, 30, and 36 inch and widths between 24 inch and 96 inch (1525 mm) in 6-inch increments. Work surfaces 72 inches and longer will require additional supports.

4.3. Cable management. Panel hung Work surfaces shall

have a continuous reveal at back edge approximately 1” wide to permit the passage of power & equipment cables where the surface meets the panel.

4.3.1. In l ieu of a continuous reveal, scalloped edges or

unobstructed color coordinated grommets may be provided in the following quantities:

4.3.1.1. Work surfaces less than 48 inches –

minimum of one (1)

4.3.1.2. Work surfaces 48 inches or more -

minimum of two (2)

5. ADJUSTABLE HEIGHT LAMINATE TOP (SIT-TO STAND)

DESK WITH WIRE MANAGEMENT: N/A

5.1. Tops. Shall be a minimum of 1” thick, 40-50# density

particle board with a high-pressure laminate.

5.1.1. Edge. All edges shall be ABS or PVC plastic

(softened rim) in finish to match plastic laminate.

Name of Of f eror: Technical Ev aluation 7

Renov ation Furniture N/A Not Acceptable Acceptable Comments

5.2. Base. Bases shall be an electric, height-adjustable, with metal column legs, providing a tabletop height of ± 22” – ± 47” high, controlled by a central control box for synchronization. Column legs must be precision balanced to minimize surface vibrations.

5.2.1. Finish. Metall ic shall be included in bid price.

5.2.2. Construction: Distributed weight capacity must be

minimum of 250 pounds

5.2.3. Cable management: Telescoping leg shall provide

a vertical race way that permits the power cords & network patch cords to route below the table, down one leg to base raceway mounted system furniture power & network

5.2.4. Leveling: Leveling glides must be capable of

adjusting ½” to accommodate uneven floors.

5.3. Wire Management System. Table must have an

integrated cable management below the table that permits the power, network cords to route below the table, down one leg to base raceway mounted system furniture power outlet

5.3.1. Vertical Cable Carrier Flexible cable

management conduit to conceal and protect power and data wire management from table surface to floor.

Cable carrier must be a minimum of 48” long.

5.4. Power System. An electrical system shall be provided

that is UL rated and meets all current National Electrical Code (NFPA 70) requirements.

5.4.1. Controller: Touch device that allows user to adjust

the surface height of the desk at a rate of approximately 1-1/2” per second by simply pushing the up and down arrows. Controller must be capable of being placed on either right or left side of desk.

5.4.2. Power Cord Minimum 9’ length cord with 15 amp

duplex plug shall be located below the table that permits the power to route down and plug into floor or wall mounted building power outlets.

Name of Of f eror: Technical Ev aluation 8

Renov ation Furniture N/A Not Acceptable Acceptable Comments

5.4.3. Power & Data Strip. Each sit-to-stand work surface

shall be provided with one 8’ power with cord & work surface edge mounted attachment.

6. LOW STORAGE TYPE 1: Typicals “2A, 2AS, 3A, 4AAS, 6A, 6AA, & 6AB N/A

6.1.1. Common Top. Approximately 18” deep and 1-1/8”

thick constructed of wood substrate with high pressure plastic laminate finish with matching ABS edge. Top must be notched and finished with plastic grommet to accommodate wire management and leg for sit-to-stand

6.1.2. 1.5 High Drawers. One 36” wide (1) locking lateral fi le drawer and one (1) locking box drawer above.

Drawers shall be centered in the unit.

6.1.3. 1.5 High storage shelves. Open shelving with one adjustable shelf.

6.1.4. 1 High Storage Shelves. Open shelving shall be approximately 16” high and have approximately 10.5” usable depth with removable back panel for access to outlets behind storage unit.

6.1.5. Cushion Top. Lateral fi le unit shall have a fabric

upholstered cushion top for guest seating.

6.1.6. Base. 3” high plinth base or architectural leg with

leveling glides adjustable to +/- 3/4”

6.1.7. Construction. Components may be constructed of

steel with factory-baked enamel finish or wood substrate with high pressure plastic laminate finish

7. LOW STORAGE TYPE 2: TYPICAL “K” RESPITE AREA N/A

7.1.1. Common Top. Approximately 18” deep and 1-1/8”

thick constructed of wood substrate with high pressure plastic laminate finish with matching ABS edge. Top must be notched and finished with plastic grommet to accommodate wire management and leg for sit-to-stand

7.1.2. 1 High Drawers. One 36” wide (1) locking lateral fi le drawer

Name of Of f eror: Technical Ev aluation 9

Renov ation Furniture N/A Not Acceptable Acceptable Comments

7.1.3. 1 High Storage Shelves. Open shelving shall be approximately 16” high and have approximately 10.5” usable depth with removable back panel for access to outlets behind storage unit.

7.1.4. Cushion Top. Lateral fi le unit shall have a fabric

upholstered cushion top for guest seating.

7.1.5. Base. 3” high plinth base or architectural leg with

leveling glides adjustable to +/- 3/4”

7.1.6. Construction. Components may be constructed of

steel with factory-baked enamel finish or wood substrate with high pressure plastic laminate finish

8. PEDESTALS AND DRAWERS: N/A

8.1. Drawer pedestals must have designer metal pull handles

such as a bar pull or similar.

8.1.1. Cushion Top. Mobile pedestals shall have a fabric

upholstered cushion top for guest seating.

8.1.2. Drawers. Pedestals shall be provided in the

various drawer combinations as shown on the typical and shall be locking.

8.1.2.1. Pencil Tray. A minimum of one (1)

shall be provided with each Box/File pedestal.

8.1.2.2. Box drawers. Shall be a minimum of

four (4) inches deep and shall have one removable

8.1.2.3. File drawers. File drawers shall have a

minimum inside dimension of 12” wide X 9.5” tall and integral rail with adequate clearance to accommodate letter size hanging folders with tabs.

8.2. Glides. Drawers shall have heavy duty bearing glides.

All drawer suspension shall be constructed so as to not expose the user to grease or sharp edges.

8.3. Construction. Components may be constructed of steel

with factory-baked enamel finish and designed for commercial office use

Name of Of f eror: Technical Ev aluation 10

Renov ation Furniture N/A Not Acceptable Acceptable Comments

9. SYSTEM FURNITURE OVERHEAD COMPONENTS – PANEL

HUNG N/A

9.1. Doors. Lockable closed shelving shall be provided with

a door constructed of a glazed panel with metal trim. Doors may be hinged, sliding, fl ip up & over, or fl ip up & receding.

9.1.1. Glazing. Back-painted glass or frosted glazing

shall be available.

9.2. Dimensions. Interior of closed units and shelves shall

accommodate a minimum of 12” deep by 12” tall objects.

9.3. Accessories. A minimum of one (1) steel shelf divider

per l inear foot shall be provided for each shelf and upper storage component.

9.4. Construction. Components may be constructed of steel

with factory-baked enamel finish or wood substrate with high pressure plastic laminate finish

10. PERSONAL STORAGE CABINETS: N/A

10.1. Storage Cabinet. Furniture products shall include a

closed lockable combination metal storage cabinet, style to coordinate with systems furniture workstations.

10.1.1. One side shall have a full height locking hinged

door with coat rod and one (1) fixed shelf.

10.1.2. One side shall have two locking (2) box drawers

and one locking (1) fi le drawer on the bottom and a partial height locking door with adjustable shelves on the

10.1.3. All surfaces shall be finished.

10.1.4. Construction. Components shall be constructed of

steel with factory-baked enamel finish

ARCHITECTURAL WALLS: Typicals “AW-1, AW-2, AW-3, AW-4, & AW-5” N/A

11. ARCHITECTRUAL WALLS - PANELS, PANEL FACES, &

DOORS: N/A

Name of Of f eror: Technical Ev aluation 11

Renov ation Furniture N/A Not Acceptable Acceptable Comments

11.1. Product Quality & Aesthetics: Architectural walls may

be either Unitized (factory built-fully assembled panels for ti lt-in installation) OR Demountable (components arrive and are assembled on site) and have a reveal design with vertical slotting for wall hung furniture components.

11.2. Panel Dimensions. Architectural wall panels shall be

floor to ceil ing design, capable of ceil ing heights up to 9’ high and panel widths must be able to accommodate proposed design. Panels must be stackable to accommodate ceil ing height changes and panel type changes. Frames (with panel faces attached) shall not exceed 4 inches thick,

11.3. Panel Face. Panel faces (skins) shall be removable

from the frame and interchangeable in the field without disassembly of the complete unit. Solid walls skins shall be constructed of 22 gauge steel skins, gypsum board panel faces will NOT be considered. The following panel face finishes shall be available, refer to typicals for project

11.3.1. Metal Skins: A metal skins shall be factory

finished powder coated steel, available in choice of finish including marker board finish.

11.3.2. Captured Glass Frame: Glazed frame assemblies

shall be constructed of ¼” tempered glass and accommodate single or double glazed configurations (refer to typical drawings)..

11.4. Panel Connections & Framing Components:

Architectural wall systems shall be capable of connecting in a variety of configurations. Panel based systems shall allow for the connection of panels with different panel face finishes and the connection of two, three or four panels from a single

11.4.1. The connector system shall provide tight

connections, which provide continuous visual and acoustical seals.

11.4.2. Each junction shall have an extruded metal cover

that shall match finish and color of the panel trim.

Name of Of f eror: Technical Ev aluation 12

Renov ation Furniture N/A Not Acceptable Acceptable Comments

11.4.3. The connector system shall provide, as required, for the continuation of power and data wiring within

11.4.4. End fi l lers for Architectural wall adjacent to fixed walls and columns shall be similar in construction to solid wall skins and fit into end channel on abutting wall.

11.4.5. Ceiling track shall be one piece continuous

formed steel and shall be capable of being installed to the underside of suspended ceil ings without using destructive fasteners.

11.4.6. Floor track shall be one piece continuous formed

steel and shall be capable of being installed on hard floor surfaces and carpeted flooring without the use of mechanical fasteners.

11.5. Doors. Architectural wall system shall be capable of

providing the following door types:

11.5.1. Slide Doors: Slide doors shall be fully supported

by wall structure without requiring additional structural support from other architectural elements. Doors shall include fascia, header and track, finished opening frame and sliding door. Roller assemblies shall be constructed of steel with high quality ball bearing wheels and include pneumatic braking mechanism.

11.5.2. Frame: Door frame shall be formed steel and

aluminum and shall include continuous resil ient sound seal at top and side jambs. Frame shall be capable of providing vertical adjustment to compensate for floor and ceil ing irregularities without the need to cut the doors on

11.5.2.1. KEYING: (Stanley/Best 1E Mortise

Cylinder with Best 7-pin construction core) in finish 626.

11.5.3. Door leaves: Doors shall be pre-finished and leafs

shall be available in the following options:

11.5.3.1.1. 3/8” tempered glass (frameless) fully glazed.

Name of Of f eror: Technical Ev aluation 13

Renov ation Furniture N/A Not Acceptable Acceptable Comments

11.6. Leveling and alignment. The system shall provide

precise alignment of adjacent panels and shall provide a 3” vertical adjustment (+/- 1-1/2”) in overall height to compensate for uneven floors and ceil ing irregularities.

11.7. Sound attenuation: Solid and framed glass systems

must be in compliance with ASTM E 72 “standard test methods of conducting strength tests of panels for building

11.7.1. Steel Clad Skins: Wall with steel clad skins must

meet a minimum 42 STC without field added insulation or gaskets.

11.7.2. Glazed Walls: Single glazed walls must meet a

minimum of 30 STC with ¼” glass.

12. ARCHITECTURAL WALL - POWER AND DATA

DISTRIBUTION: N/A

12.1. Power and Data. Panels shall have a system capable

of distributing power service and data service to multiple workstations through separate feed points.

12.1.1. Base Feed: Power & Data must be capable of

entering the wall by the following methods:

12.1.1.1.1. Power & Data feeds may be

through ceil ing junction boxes. Note: power & data may not be run adjacent through the same panel unless it is either separated by a minimum of 24” or in flexible metal conduit

12.1.2. Distribution:

12.1.2.1. Power and data must be separated by a

minimum of 24” at all points within the panel and feeds. The power and data cables shall NOT cross each other. NOTE: Power wire harnesses that are constructed of shielded flexible metal conduit are not required to maintain 24” separation

Name of Of f eror: Technical Ev aluation 14

Renov ation Furniture N/A Not Acceptable Acceptable Comments

12.1.3. Power System. Power/Data panels shall include

an electrical system that is UL rated and meets all current National Electrical Code (NFPA 70) requirements. A minimum 8-wire, 3-circuit system (with minimum 20-amp 125 volts per circuit capacity) and minimum #12 AWG wire size shall be used. NOTE: 10 wire, 4 circuit system may be substituted, prov ided separate neutrals are prov ided for each circuit.

12.1.3.1. The power wiring system must provide

a separate and unique neutral conductor per circuit (i.e.: 3 circuits, 3 neutrals, and 2 grounds

12.1.3.2. Knockout plates capable of accepting

duplex receptacles (20 amp 125 volt capacity) shall be provided in all identified powered panels.

12.1.3.3. Duplex receptacles shall be provided

as shown on the typical. Power outlets shall be 20 amps duplex (NEMA 5-20R).

12.1.3.4. The power wiring harness system shall

be located in or near the base of the panels.

12.1.3.5. The wiring harness system shall be

enclosed in flexible metal conduit.

12.1.4. Data Cable Management. Power/Data panels

shall have a data channel that is properly separated OR shielded from electrical sources. Panels shall offer the following capacities for routing data cables.

12.1.4.1. Furniture vendors shall provide flush

mounted faceplates, bezel and blank covers capable of accepting standard Aeronautical Center

Name of Of f eror: Technical Ev aluation 15

Renov ation Furniture N/A Not Acceptable Acceptable Comments

12.1.4.1.1. Knockout plates in the panel face

shall be capable of providing a minimum of 3 potential jacks per workstation. Data faceplates must be capable of three (3) RJ45 Systimax, Part # MGS400BH-112 (ORANGE) at each location shown

13. POWERED CONFERENCE TABLES &

BENCHING SYSTEM: Typicals “C1, C2, C3, & E” N/A

14. PLASTIC LAMINATE CONFERENCE TABLE: Typicals C1-C2 N/A

14.1. Tops. Table top shall be plastic laminate over wood

substrate with a matching wood grain PVC or ABS edge approximately 1 ¼” thick with a modern design.

14.1.1. Cutouts. Work surface tops shall have linear cut

outs for power/data module access doors centered on the work surface

14.2. Wire Management: Tables must provide a path for

power and network from Power Modules to below the table in a race way that permits the power to route through the table, down the hollow base and into floor mounted building power

14.3. Architectural Base Typical C1 Polished metal shall

have a modern architectural style and shall be hollow for wire management, refer to photo on typical for design intent.

14.4. Panel Base Typicals C2 Bases shall be plastic laminate

on wood substrate or have a combination of metal and plastic laminate designer features. Provide a minimum of 27” high clearance. Bases shall be hollow for wire management & equipped with a removable or hinged panel

15. COLLABORATIVE TABLE WITH MONITOR WALL – Typical “C3” N/A

Name of Of f eror: Technical Ev aluation 16

Renov ation Furniture N/A Not Acceptable Acceptable Comments

15.1. Tops. Shall have high pressure plastic laminate over

wood substrate with PVC or ABS plastic edge approximately 1 1/8 thick or other acceptable heavy-duty design.

15.2. Base. Metal or wood base shall provide a minimum of

27” high knee clearance. Bases shall be integrated into the table & media wall design and serve as a wire management path from the table to the media wall.

15.3. Monitor Wall. Monitor mount wall that provides a

convenient and attractive means of mounting monitors and is either mounted or integrated into conference table (not wall mounted) and have vertical wire management path for monitor. May be constructed of high pressure plastic laminate over wood substrate w/ metal accents, aluminum or steel with factory-backed enamel finish, offered in colors to match other exposed metal table components

15.4. Cameral shelf. Shelf or ledge that mounts to monitor

wall, may be constructed of high pressure plastic laminate over wood substrate, aluminum or steel with factory-backed enamel finish, offered in colors to match exposed metal

15.5. Wire Management System. Table must have an

integrated cable track below the table that permits the power, network and A/V cords to route through the table from the power/data module to the monitor wall and also to the

16. BENCHING SYSTEM: TYPICAL “E” N/A

16.1. Product Quality & Aesthetics. Benching system

constructed of dual-sided base units (with work surfaces) with an integrated rail frame system with intermediate support legs. Bench system shall be capable of 6-pack units that shall be equal the total length and width required by typical.

16.2. Tops. Shall be a minimum of 1” thick, 40-50# density

wood substrate with a high-pressure laminate.

16.2.1. Cutouts. Work surface tops shall have linear cut

outs for power/data module access doors centered on the work surface

Name of Of f eror: Technical Ev aluation 17

Renov ation Furniture N/A Not Acceptable Acceptable Comments

16.3. Wire Management: Metal wire management tray shall

be integrated into the frame system, located below the work surfaces for power and separate data wire management tray or cable hangars mechanically attached to the underside of the work surfaces or frame.

16.3.1. Edge. All edges shall be ABS or PVC plastic

(softened rim) in finish to match plastic laminate.

16.3.2. Privacy Screen. Benching system shall have a

partial height privacy screens extending the full width of the work surface and extend approximately 18” above work surface.

16.3.2.1. Hardware. Privacy screens shall have

surface-mounted hardware that mechanically fastens to the center rail structure.

16.3.2.2. Construction: Privacy screens may be

constructed of fabric covered acoustical panels, glazed panel, or metal tool rail panel.

16.4. Base. Bases shall be constructed of metal frame

providing a tabletop height of +/- 29” high. Base shall have center rail metal frame systems with intermediate legs

17. POWER & NETWORK SYSTEMS: N/A

17.1.1. Power System. Conference tables C1, C2, C3 &

Bench system Typical E shall include an electrical system that is UL rated and meets all current National Electrical Code (NFPA 70) requirements.

17.1.1.1. Wire Harness. For use on Typical E A

minimum 8-wire, 3-circuit system (with minimum 20-amp 125 volts per circuit capacity) and minimum #12 AWG wire size shall be used.

17.1.1.2. The power wiring system must provide

a separate and unique neutral conductor per circuit (i.e.: 3 circuits, 3 neutrals, and 2 grounds

17.1.1.3. Each 3-3-2 power wiring system shall

serve a maximum of eight (8) workstations.

Name of Of f eror: Technical Ev aluation 18

Renov ation Furniture N/A Not Acceptable Acceptable Comments

17.1.1.4. The wiring harness system shall be

enclosed in flexible metal conduit or l iquid-tight conduit. Power harness shall run in a cable tray that permits the power to route beneath the work surfaces, down the base and into floor mounted j-box and hard wired into the building’s power

17.1.2. Power Data Module Type-1. Refer to Typical E

for quantities: Each Module shall have the following:

Minimum of two (2) duplex outlets (or 4 simplex outlets), two (2) RJ- 45 connections Power Data Module Type-2: Typicals C1, C3 & C3 power modules must have a minimum of one (1) duplex outlet (or 2 simplex outlets), one (1) AV faceplate with one (1) RJ-45 connections and at least two

(2) additional blank plates for future use.

NOTE: Blank AV faceplates must be capable of connecting one (1) VGA, one (1) Audio outlet, and one (1) HDMI in.

17.1.2.1. Type-2 power module shall contain 8’-

10’ long Direct Plug-In 15 amp power cord.

17.1.3. All Power modules MUST prov ide a slotted

opening for cord passage when hinged door is in closed position.

17.1.4. Data Cable Management. Data wire

management tray or cable hangars mechanically attached to the underside of the work surfaces or frame that permits the data cables to be routed from a j-box below the raised floor, through the benching system base and terminated in the power/data matrix.

17.1.4.1. Furniture vendors shall provide flush

mounted faceplates, bezel and blank covers capable of accepting standard Aeronautical Center

Name of Of f eror: Technical Ev aluation 19

Renov ation Furniture N/A Not Acceptable Acceptable Comments

17.1.4.1.1. Knockout plates in the

power/data matrix shall be capable of providing a minimum of 2 potential jacks per position & must be capable of accepting RJ45 Systimax, Part # MGS400BH-112

MANAGER & OA WORK STATIONS: Typicals “D1, D2, D3 & D4” N/A

18. STYLE: N/A

18.1. Modern Plastic Laminate Furniture –Shall have wood

grain plastic laminate over wood substrate with a modern edge. Overheads shall have glazed doors with metal trim.

Fabric tack boards shall be provided between overheads and work surface. Full-height cabinets shall have wood grain plastic laminate doors. Hardware shall be silver colored modern style (such as a metal l inear bar or other designer

19. PLASTIC LAMINATE CONTRACTOR OFFICE DESK: Typical D1 N/A

19.1. Tops. Shall have a rectangular top constructed of

plastic laminate over wood substrate with a matching pvc

19.2. End panels. Where visible provide metal architectural

support panel.

19.3. Modesty Panels:

19.3.1. Front modesty panels shall be partial height, glazed or metal suspended below work surface

20. PLASTIC LAMINATE MANAGER OFFICE DESK: Typical D2 N/A

20.1. Tops. Shall may be rectangular top with radius end or

other specialty shape designed to encourage meetings.

constructed of plastic laminate over wood substrate with a matching pvc edge

20.2. End Panels/Support Post. Where visible provide metal

architectural support panel or tubular post.

20.3. Modesty Panels:

Name of Of f eror: Technical Ev aluation 20

Renov ation Furniture N/A Not Acceptable Acceptable Comments

20.3.1. Front modesty panels shall be partial height, glazed or metal suspended below work surface

21. PLASTIC LAMINATE RECEPTION WORKSTATION: Typical D3 N/A

21.1. Tops. Shall have plastic laminate over wood substrate

with a matching pvc edge.

21.2. Designer Front Panels. Reception height wood grain

laminate privacy panels 36-42” high, depending on transaction top thickness, with accent panel of different material such as frosted glazing, metal, or other modern

21.3. Transaction Top. Glazed or other accent material

transaction top shall appear to be “floating” above privacy panels with a reveal, metal stand-off, or other designer

21.4. Pedestals and drawers. Plastic laminate pedestal shall

be provided as shown. Drawers shall be lockable.

21.4.1. Drawers. Mobile pedestals shall be locking and

provide the following.

21.4.2. Pencil Tray. A minimum of one (1) shall be

provided with each Box/File pedestal.

21.4.3. Box drawers. Shall be a minimum of four (4)

inches deep and shall have one removable divider.

21.4.4. File drawers. File drawers shall have a minimum

inside dimension of 12” wide X 9.5” tall and integral rail with adequate clearance to accommodate letter size hanging folders with tabs. File drawers shall have full extension ball bearing suspensions.

21.5. Construction. All exposed surfaces shall be constructed of plastic laminate over wood substrate with glazed and metal accents to coordinate.

22. ADJUSTABLE HEIGHT (SIT-TO STAND) LAMINATE TOP

DESK/RETURN Typicals D1, D2, D3, & D4 N/A

Name of Of f eror: Technical Ev aluation 21

Renov ation Furniture N/A Not Acceptable Acceptable Comments

22.1. Tops. Shall be a minimum of 1” thick, 40-50# density

particle board with a high-pressure laminate. Surfaces shall be balanced to resist warping, and underside shall be smoothly finished.

22.1.1. Edge. All edges shall be ABS or PVC plastic

(softened rim) in finish to match plastic laminate.

22.2. Base. Base shall contain an integrated electric, height-adjustable work surface top with total height adjustment of ± 29” – ± 42” high, controlled by a central control box for synchronization. Column legs must be precision balanced to minimize surface vibrations.

22.2.1. Construction: Distributed weight capacity must be

minimum of 200 pounds

22.2.2. Cable management: Telescoping leg shall

provide a vertical race way that permits the power cords & network patch cords to route below the table, down one leg to wall power outlets.

22.2.3. Leveling: Leveling glides must be capable of

adjusting ½” to accommodate uneven floors.

22.3. Wire Management System. Table must have an

integrated cable management below the table that permits the power, network cords to route below the table, down one leg to recessed floor power outlets (Walker Boxes).

22.3.1. Vertical Cable Carrier Flexible cable

management conduit to conceal and protect power and data wire management from table surface to floor.

Cable carrier must be a minimum of 48” long.

22.4. Power System. An electrical system shall be provided

that is UL rated and meets all current National Electrical Code (NFPA 70) requirements.

Name of Of f eror: Technical Ev aluation 22

Renov ation Furniture N/A Not Acceptable Acceptable Comments

22.4.1. Controller: Touch device that allows user to

adjust the surface height of the desk at a rate of approximately 1-1/2” per second by simply pushing the up and down arrows. Controller must be capable of placed on either right or left side of desk.

22.4.2. Power Cord Minimum 9’ length cord with 15 amp

duplex plug shall be located below the table that permits the power to route down and plug into floor or wall mounted building power outlets.

23. PLASTIC LAMINATE CREDENZA Typicals D1, D2, D3 & D4 N/A

23.1. Work Surface Tops. Shall be a minimum of 1” thick, 40-

50# density wood substrate, with a high-pressure laminate.

23.2. End panels. Where visible provide solid end panels.

23.3. Modesty Panels:

23.3.1. Back modesty panels (if required) shall be partial

height where adjacent to a wall for access to wall power and data outlets.

23.4. Wire Management. Components shall have metal

grommets or continuous reveal.

23.5. Construction. All exposed surfaces shall be constructed of plastic laminate over wood substrate with matching wood grain PVC or ABS Plastic edge.

24. PLASTIC LAMINATE OVERHEADS (HUTCH): Typicals D1, D2, D3 & D4 N/A

24.1. Types. REFER TO TYPICALS for requirements.

24.1.1. Overheads shall be freestanding NOT wall

24.1.2. Overheads shall be single-height

24.1.3. Overheads shall have back painted glazed doors

with metal trim

24.1.4. Overheads shall be in various widths to match

work surfaces.

24.2. Dimensions. A minimum inside clear dimension of

10.5” deep and 12.5” tall shall be provided inside closed

Name of Of f eror: Technical Ev aluation 23

Renov ation Furniture N/A Not Acceptable Acceptable Comments

24.3. Tack boards. Fabric tack boards shall be provided

between overhead and work surface.

24.4. Hardware. Hardware shall be metall ic colored modern

style.

24.5. Construction. All exposed surfaces shall be constructed of plastic laminate over wood substrate with matching wood grain PVC or ABS Plastic edge.

25. PLASTIC LAMINATE DESKTOP STORAGE CABINET:

Typicals D4 N/A

25.1. Types. Freestanding work surface mounted storage, height to match overheads, refer to typicals for requirements.

25.2. Desktop Storage Cabinet. Storage shall include

hinged solid door(s) with adjustable shelves, may contain other storage features not described in specs.

25.3. All exposed surfaces shall be finished.

25.4. Hardware. Hardware shall be metall ic colored modern

style (such as a metal l inear bar or other designer hardware).

25.5. Construction. All exposed surfaces shall be constructed of plastic laminate over wood substrate with matching wood grain PVC or ABS Plastic edge.

26. COMBINATION STORAGE CABINET: Typicals D1, D2, D3 & D4 N/A

26.1. Combo Cabinet. Furniture products shall include a

closed combination cabinet with two (2) laterals fi le drawers on the bottom and hinged solid doors with two (2) adjustable shelves on the top, and one full height door +/- 6” wide with coat hook/rod

26.2. Locks. Cabinets shall be lockable.

26.3. Hardware. Hardware shall be metall ic colored modern

style (such as a metal l inear bar or other designer hardware).

26.4. Construction. All exposed surfaces shall be constructed of plastic laminate over wood substrate with matching wood grain PVC or ABS Plastic edge.

Name of Of f eror: Technical Ev aluation 24

Renov ation Furniture N/A Not Acceptable Acceptable Comments

27. 2-DRAWER LATERAL-FILE CABINET : Typicals D1, D2, D3 & D4 N/A

27.1. Lateral File Dimension. 30 wide x +/- 20” deep 27”

27.1.1. Desks and Front Work surfaces. Pedestals on

desks and front work surfaces shall compliment the work surface top.

27.1.2. Side and Back Work surfaces. Pedestals on side

and back work surfaces shall compliment the work surface top. Pedestals should extend to the underneath side of the work surface.

27.2. Drawers. Lateral fi le cabinet shall be locking and

provide the following.

27.2.1. Lateral fi le drawers. File drawers shall have a

minimum inside dimension of 12” deep X 9.5” tall and integral rail with adequate clearance to accommodate letter size hanging folders with tabs.

27.2.2. Hanging Folder Frames. Each drawer shall be

equipped with hanging folder frames to support both legal and letter size material fi led both laterally and front to back and with adjustable dividers.

27.3. Hardware. Hardware shall be silver colored modern

style (such as a metal l inear bar or other designer hardware).

27.4. Construction. All exposed surfaces shall be constructed of plastic laminate over wood substrate with matching wood grain PVC or ABS Plastic edge.

DESK & WORK STATION ACCESSORIES:

Typicals “2A, 2AS, 2B, 3A, 4AAS, 4BB, 4BBS, 6A, 6AA, 6AB, 6BB, D1, D2, D3, D4, E, & K”

N/A

28. KEYING. N/A

28.1. Furniture products shall be keyed with a master keying

system. A minimum of two (2) master keys shall be provided.

Name of Of f eror: Technical Ev aluation 25

Renov ation Furniture N/A Not Acceptable Acceptable Comments

28.1.1. All locking components within each workstation

shall be keyed identical.

28.1.2. Keys and lock cylinders shall be numbered for

ease of identification and replacement.

28.1.3. A minimum of 50 different keying options shall

be available.

28.1.4. A minimum of four (4) keys for each workstation

shall be provided.

28.2. A proposed keying schedule shall be developed prior to

installation and approved by the FAA

28.3. At the completion of the project, an as-installed key

schedule shall be provided.

29. DUAL MONITOR ARMS – N/A

29.1. Product Quality & Features: Similar to ISE MA4000

Series adjustable monitor arms in style and function, or equal . Must have dual arm monitor mounts.

Features. Fully adjustable arm with a grommet mount or clamp mount shall have the following features

29.1.1. Counterbalance spring mechanism for smooth

dynamic height adjustment

29.1.2. Arm height position adjustable on the pole

29.1.3. Articulating arm segments that allow the

monitors to fold back to the pole to create more desk space with minimum of 13” front arm segment

29.1.4. Cable manager to keep all cables hidden.

29.1.5. Quick disconnect for fast monitor mounting.

29.1.6. 12” high stainless steel pole

29.1.7. 24” arm lengths

29.1.8. Maximum load of 20 lbs. per arm.

29.1.9. Landscape and Portrait rotation on ball joint;

30. LIGHTING: N/A

30.1. General. Furniture products shall have Underwriters’

Laboratories (UL) tested task lighting.

30.1.1. Upper storage task lighting.

Name of Of f eror: Technical Ev aluation 26

Renov ation Furniture N/A Not Acceptable Acceptable Comments

30.1.1.1. Diffusion lens and be shielded to

prevent direct viewing of the lamp or bulb at eye level from a seated position.

30.1.1.2. LED lamps

30.1.1.3. Individual on/off switches.

30.1.1.4. Approximately eight (8) feet of power

cord capable of being concealed.

30.1.1.5. Linear feet of coverage to coordinate

with the minimum requirements shown on typicals.

30.1.2. Freestanding Table Lamp. Style to coordinate

with workstation components. Finish shall match hardware and trim.

30.1.2.1. LED lamps.

30.1.2.2. Individual on-off switches.

30.1.2.3. Approximately eight (6) feet of power

cord capable of being concealed.

31. ENERGY SAVING CONTROL SYSTEM: N/A

31.1. General. Furniture products shall have Underwriters’

Laboratories (UL) Energy Saving Control System capable of controll ing task lighting, and other power equipment when workstation is vacant. Products similar to Insole IDP-3050 Plug Load Control “Watt Stopper” or equal.

31.1.1. Outlets. Minimum six (6) power outlets controlled

by the sensor and a minimum of two (2) uncontrolled.

31.1.2. Switches. On/Off switch to turn on or off outlets.

31.1.3. Personal Sensor. Util izing passive infrared

technology to detect occupancy within a workspace.

Similar to Insole DI-110 Personal Sensor or equal.

31.1.4. Length. Minimum six (6) feet of power cord

capable of being concealed.

31.2. Other products meeting the same intent of controll ing

the on/off of powered equipment when the workstation is vacant will be considered acceptable

Name of Of f eror: Technical Ev aluation 27

Renov ation Furniture N/A Not Acceptable Acceptable Comments

FREESTANDING STORAGE & BREAK AREA

FURNITURE: N/A

Typicals “F, G, H, S1, S2, S3, S4, S5, & S6 N/A

32. BANQUETTE SEATING – Upholstered: TYPICAL “F” N/A

32.1. Dimensions. Seat Height +/-18”, Seat Depth +/-20”, Seat Back (+/-) 56. Width must match overall requirements of

32.2. Back & Base Cushions have shaped polyurethane foam

stretched over web sheet and attached to frame. Upholstery shall be available in different fabric than base for a two tone effect.

32.3. Base. Seat base shall have quality suspension spring

system with shaped polyurethane foam stretched over web sheet and attached to frame. Upholstery shall be available in different fabric than back for a two tone effect.

32.4. Frame. Metal or upholstered wood frame with corner

blocks and reinforcements at all stress points.

32.4.1. Leg. Exposed metal cylindrical leg with 1”

adjustable leveling glides.

32.4.2. Arms. Armless.

32.5. Power System. Seating shall include a frame mounted

electrical system that is UL rated and meets all current National Electrical Code requirements. NOTE only required on phase 2 banquette.

32.5.1.1. The power wiring system must provide a

minimum 6’ cord with 15-amp grounded plug

32.5.1.2. Duplex receptacles shall be provided

integrated into the furniture and may be located on the seat base shown on typical or may be placed on other areas, provided they meet the overall design intent.

32.6. Fabric and Vinyl options. Grade 5/6 – Pattern and

color to be selected from manufacturer’s standards.

33. BANQUETTE TABLES – Plastic Laminate – TYPICAL “F” N/A

Name of Of f eror: Technical Ev aluation 28

Renov ation Furniture N/A Not Acceptable Acceptable Comments

33.1. Tops. Shall be a minimum of 1” thick, 40-50# density

particle board, plywood, or MDF with a high-pressure

33.1.1. Edge. All edges shall be ABS or PVC plastic

(softened rim) in finish to match plastic laminate.

33.2. Frame. Frame shall have a single metal cylindrical

pedestal support with a flat disk base with leveling glides providing a tabletop height of +/- 29” high.

33.2.1. Finish. Silver metall ic shall be included in bid

price.

34. BREAK ROOM TABLES – Plastic Laminate: TYPICAL “G” N/A

34.1. Types. Rectangular +/-30”Dia x +/-29” high.

34.2. Tops. Shall be a minimum of 1” thick, 40-50# density

particle board, plywood, or MDF with a high-pressure

34.2.1. Edge. All edges shall be ABS or PVC plastic

(softened rim) in finish to match plastic laminate.

34.3. Frame. Frame shall have one (1) metal tubular supports

legs providing a tabletop height of 42” high.

35. BREAK ROOM CHAIR (armless): TYICAL “G’ N/A

35.1. Style. Metal frame molded shell chair.

35.2. Features.

35.2.1. Dimensions. (+/-) 20”W x 23” D x 33” H. SEAT

HEIGHT +/-17”.

35.2.2. Seat. May be either molded wood or

polypropylene with upholstered seat cushion.

35.2.3. Back. May be either flexible molded wood or

polypropylene with supporting curves & integrated cutout handle

35.2.4. Frame. Minimum ½” diameter chrome steel rod

35.2.5. Arms. Armless.

36. COUNTER HEIGHT TABLES – TYPICAL “H” N/A

Name of Of f eror: Technical Ev aluation 29

Renov ation Furniture N/A Not Acceptable Acceptable Comments

36.1. Tops. Top and sides shall be a minimum of 1” thick, 40-50# density wood substrate with a high-pressure laminate.

Table top shall have a thickened edge & surfaces shall be finished with matching laminate to create the appearance of 2-1/2” thick solid timber construction.

36.2. Frame. Café table shall have solid end panels

constructed of 1” thick, 40-50# density particle board, plywood, or MDF with a high-pressure laminate. All exposed surfaces shall be finished with matching laminate to create the appearance of 2-1/2” thick solid timber construction.

Support panels/frame shall come with leveling glides

36.2.1. Toe/kick plate. Silver metall ic stainless steel 4”

kick plate shall be included in bid price.

36.3. Accessories. Metal convenience hooks shall be

integrated into underside of table top & metal foot bar shall span between vertical support panels.

37. CAFÉ HEIGHT CHAIRS (armless) – TYPICAL “H” N/A

37.1. Style. Metal frame molded shell chair.

37.2. Features.

37.2.1. Dimensions. (+/-) 25”W x 23” D x +/-45” H. SEAT

HEIGHT +/-30”.

37.2.2. Seat. May be either molded wood or

polypropylene with upholstered seat cushion.

37.2.3. Back. May be either flexible molded wood or

polypropylene with supporting curves & integrated cutout handle

37.2.4. Frame. Minimum ½” diameter chrome steel rod

with three sided foot ledge

37.2.5. Arms. Armless.

38. LATERAL FILE CABINETS (Steel): TYPICAL “S1” N/A

38.1. Types:

38.1.1. 5-High Lateral File Cabinets shall have four (4) drawers and one (1) shelf with fl ipper door. REFER TO TYPICALS “S1” for requirements.

Name of Of f eror: Technical Ev aluation 30

Renov ation Furniture N/A Not Acceptable Acceptable Comments

38.2. Construction. Shall be constructed of steel, designed

for commercial office use.

38.3. Case. Shall be designed to hold both fixed front

drawers or roll out shelves with receding doors, with four (4) adjustable glides.

38.3.1. Minimum inside clearances. A minimum clear

inside height dimension of ten (10) inches shall be provided for drawers and twelve (12) inches for shelves.

38.3.2. Hanging Folder Frames. Each drawer shall be

equipped with hanging folder frames to support both legal and letter size material fi led both laterally and front to back and with adjustable dividers.

38.3.3. Counter balances. Attached counter balances

shall be provided in all freestanding lateral fi les cabinets except the five tier cabinets.

38.3.4. Suspension system. Rolling drawers and shelves

shall have full extension ball bearing suspensions, and extend far enough to allow unobstructed insertion and removal of hanging fi les and their contents.

38.3.5. Locks. All lateral fi le cabinets shall be equipped

with a locking mechanism to control the locking of all cabinet compartments.

38.3.6. Pulls. Recessed or full-face type, which includes

a label holder.

38.3.7. Vertical dividers. Dividers shall retain both legal

and letter size documents adequately and shall be designed to snap securely in the drawers and shelves without the use of tools or attaching devices.

38.4. Finish. All visible surfaces shall be coated with the

baked enamel or electrostatically applied powder base paint.

39. CLOSED STORAGE CABINET – TYPICAL “S2” N/A

39.1. Storage Cabinet. Furniture products shall include a

closed lockable metal storage cabinet.

Name of Of f eror: Technical Ev aluation 31

Renov ation Furniture N/A Not Acceptable Acceptable Comments

39.1.1. Shall have two (2) full height locking hinged

doors and four (4) adjustable shelves.

39.1.2. Shelves. Shall be constructed of 20-guage steel

and adjustable in 1-1/2” increments with shelf clips.

39.1.3. Construction. Shall be constructed of steel with

factory-backed enamel finish, offered in colors to match exposed metal components

40. SHELVING UNIT – TYPICAL “S3” N/A

40.1. Types: ±66”H steel shelving unit shall have five (5) steel shelves. REFER TO TYPICAL “S3” for requirements.

40.2. Case. Side and back panels shall be designed of 24-

gauge steel to prevent product roll-off.

40.3. Shelves. Shall be constructed of 20-guage steel and

adjustable in 1-1/2” increments with shelf clips.

40.3.1. Construction. Shall be constructed of steel with

factory-backed enamel finish, offered in colors to match exposed metal components

41. 3-HIGH STORAGE ISLAND WITH WORKSURFACE TOPS –

TYPICAL “S4” N/A

41.1. Storage Cabinet. Furniture products shall include a

closed lockable metal storage cabinet & lateral fi le cabinets, style to coordinate with systems furniture workstations.

41.2. Tops. Shall be a minimum of 1” thick, 40-50# density

particle board with a high-pressure laminate. Surfaces shall be balanced to resist warping, and underside shall be smoothly finished.

41.2.1. Metal 3-high closed door cabinets with three (3)

shelves.

41.2.1.1. Cabinet shall have a full height locking

hinged door with two (2) adjustable shelves.

41.2.2. Metal 3-high lateral fi les.

41.2.3. Construction. Components may be constructed of

steel with factory-baked enamel finish and designed for commercial office use.

Name of Of f eror: Technical Ev aluation 32

Renov ation Furniture N/A Not Acceptable Acceptable Comments

42. 2-HIGH STORAGE WORK AREA WITH WORKSURFACE

TOPS – TYPICAL “S5” N/A

42.1. Tops. Shall be a minimum of 1” thick, 40-50# density

particle board with a high-pressure laminate.

42.1.1. Metal 2-high Closed door cabinets with two (2)

shelves

42.1.1.1. Cabinet shall have a full…

This is the start of the file's text. The full file is on GovTribe.