This specifications document outlines requirements for office furniture to be provided under Solicitation Number 6973GH-22-Q-00001 for the Department of Transportation Federal Aviation Administration. Products required include powered systems furniture, demountable architectural wall systems, and freestanding office furniture. The specifications provide details on panel frames, panel faces, work surfaces, overhead components, pedestals, drawers, benching systems, conference tables, and other furniture items. Bidders must meet experience qualifications for project managers and designers and provide samples, cut sheets, warranties, and other documentation. The selected vendor will complete a phased installation coordinated with the construction schedule at the Mike Monroney Aeronautical Center in Oklahoma City. The specifications establish quality standards, electrical and data requirements, finishes, and other technical specifications bidders must meet.

View the file

Other files for this federal contract opportunity

Show all 14

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

WO#14-004363

015-BMB Renovation 0

AMP-100, AMP-300, & AMP-400

Specifications for Powered Systems Furniture

Demountable Architectural Wall Systems & Freestanding Office

Furniture.

09/16/2021

015-BMB Renovation 1

AMP-100, AMP-300, & AMP-400

Specifications for Powered Systems Furniture, Architectural Wall Systems, & Freestanding Private Office Furniture

1. SCOPE: This description covers powered panel-hung systems furniture, demountable architectural wall systems, powered benching systems, & freestanding private office furniture for Base Maintenance Building (015-BMB) Renovation at the Mike Monroney Aeronautical Center.

1.1. The work to be performed under this specification consists of providing all the labor, equipment, materials, coordination, storage and transportation necessary to design, provide and install a complete and functional furniture system in accordance with this specification and accompanying typical drawings.

2. PROJECT DESIGN / BIDDING:

2.1. Modifications to the typicals may occur based upon site conditions and other factors identified during the design process. All typical dimensions, shapes, etc., are illustrated to describe the range of components that the government expects to procure. Specific orders will be placed for those items required to meet the design requirements of the project.

2.1.1. Typicals shall be designed not to exceed the boundary/footprint indicated on the typicals.

2.1.2. Proposed products shall be similar in size, appearance and function as indicated on the typicals and in these specifications.

2.1.3. References to a manufacturer’s model are ONLY for the purpose of conveying the aesthetics, quality, and function. Equal products may be substituted.

2.1.4. The layout shall conform to IBC 2003, NFPA 101 and shall be accessible in accordance with ABA guidelines.

2.2. Minimum Requirements. The components shown in the attached typicals, along with this specification, shall be considered as minimum requirements.

2.3. Experience. Furniture Contractor shall provide a Product/Project Team with bid package, which shall be available throughout the completion of the project. Minimum experience requirements are:

2.3.1. Furniture Contractor’s Project Manager - minimum of 5 years’ experience.

2.3.2. Furniture Contractor’s Designer - minimum of 3 years’ experience.

2.3.3. Furniture Contractor’s Installer - minimum of 5 years’ experience.

2.4. Project Schedule. Furniture Contractor shall provide a proposed (after award) design and installation schedule in number of workdays for the project with bid package.

Schedule should include the following activities:

2.4.1. Field verify existing dimensions (If it is not possible to field verify because of the stage of construction, indicate the critical dimensions that need to be maintained during construction, in order for the furniture to fit within the given space).

2.4.2. Prepare a product design, utilizing their product line based upon the typicals, concept plan, and actual dimensions of the areas of installation.

2.4.3. FAA Review of Design Plan (Allow 5 working days for FAA review).

2.4.4. Provide Itemized List of Components with quantity and price by typical and

Installation Parts Plan.

2.4.5. FAA Review of Itemized List of Components & Installation Parts Plan (Allow 2 days for FAA review/approval).

015-BMB Renovation 2

AMP-100, AMP-300, & AMP-400

2.4.6. Provide Itemized order confirmation.

2.4.7. Manufacturing.

2.4.8. Product Delivery.

2.4.9. Product Installation

2.5. Typical Drawings/Plans. Furniture Contractor shall provide “to scale” plans, elevations and/or 3-dimensional design drawings with bid package.

2.5.1. Furniture/Component Drawings: Show layout of individual components with mounting heights of work surfaces and components and electrical and data connections.

2.5.2. Typicals. On each Typical identify any differences or enhancements between the FAA Typical and the proposed typical and describe how these meet or exceed the minimum specifications.

2.5.3. Any components not shown in the FAA Typical, which are needed to conform to the manufacturer’s recommendations for installation, shall be included.

2.5.4. The proposed typicals will be used as a basis for evaluating the ability of each offer’s line of furniture to fulfill the requirements for this project.

2.5.5. The FAA will provide an AutoCAD 2012 format .dwg file to use as a base.

2.6. Bill of Materials / Pricing:

Vendor shall provide an itemized bill of materials for each proposed solution with bid package. The bill of materials shall include the offer’s part number, nomenclature, size, quantity and unit price of each component required for one of each typical.

2.7. Meetings. Furniture Contractor’s product team shall be required to attend the following meetings, as required:

2.7.1. Pre-Manufacturing meeting with FAA, General Contractor, and Furniture Vendor to coordinate construction schedule with furniture manufacturing lead times and delivery dates.

2.7.2. Pre-installation meeting to discuss key aspects of furniture installation.

2.7.3. Panel frame acceptance inspection meeting.

2.7.4. Product component acceptance inspection meeting.

2.7.5. Furniture Contractor’s Project Manager and Furniture Contractor’s Designer shall be available to meet onsite during the design and installation process as required.

3. SCHEDULE: Delivery and installation of furniture must be coordinated with MMAC Space Manager and Customer Organization. Project schedule currently indicates that Phase 1 installation could begin March 2022 and Phase 2 could begin June 2, 2022,

4. PHASES: The furniture installation shall consist of Four (4) phases, installation schedule shall be coordinated with the construction completion schedule.

4.1. Phase 1a South– Installation of Powered Systems Furniture Panel Frames. Install all panel frames without faces except where required for network/data connections to be terminated. This phase will occur before the building construction is completed so that the Construction General Contractor can connect the system furniture’s power harness to building power, and pull data wiring from the telco closet to each workstation data location.

4.2. Phase 1b South – Installation of Systems Furniture Components and freestanding storage. Install remaining panel faces, work surfaces, overheads, and freestanding furniture. This phase will occur after the general contractor has connected the power harness and terminated the data wiring at each work station.

4.3. Phase 2a North– Installation of Architectural Wall Systems and Powered Systems Furniture Panel Frames. Install all panel frames without faces except where required for network/data connections to be terminated. This phase will occur before the building construction is completed so that the Construction General Contractor can connect the

015-BMB Renovation 3

AMP-100, AMP-300, & AMP-400

system furniture’s power harness to building power, and pull data wiring from the telco closet to each workstation data location.

4.4. Phase 2b North – Installation of Systems Furniture Components and freestanding storage. Install remaining panel faces, work surfaces, overheads, and freestanding furniture. This phase will occur after the general contractor has connected the power harness and terminated the data wiring at each work station.

5. ORDER/DELIVERY/INSTALLATION:

5.1. Furniture Contractor shall provide all labor and materials to provide on-site management, coordination, and technical assistance throughout the installation process and complete the installation in accordance with the approved plan and installation schedule.

5.2. Ordering. Product must be ordered and delivered to meet the target completion schedule dates. NOTE: A delayed manufacturing start date MAY be required in order to avoid storing components. FAA will provide manufacturing start date after award.

5.3. Site Acceptance. A walkthrough shall be conducted to identify any existing building damage prior to the delivery and installation process

5.3.1. Furniture Contractor shall be responsible for damage to the building, which occurs during the delivery and installation process, and completing the building repairs to the satisfaction of the FAA.

5.4. Storage and Delivery. Furniture Contractor shall be responsible for:

5.4.1. Receipt, delivery and handling of all materials and supplies necessary to provide a complete installation.

5.4.2. Identifying damaged product items and having those repaired or replaced to not cause installation delays.

5.4.3. Movement of furniture from storage to the installation site as needed.

5.4.4. Furniture product shall be installed at the Base Maintenance Building (015-

BMB), 6125 South West 68th Street, Mike Monroney Aeronautical Center, Oklahoma City, OK, 73169.

5.4.4.1. Project is located on the first floor.

5.4.4.2. Dock access IS NOT available at the building.

5.4.4.3. No storage space is available inside the building or inside other

Buildings at the MMAC.

5.4.4.4. No staging space other than the installation area will be available.

5.5. Installation.

5.5.1. Furniture Contractor shall have a full-time installation crew on which a minimum of two-thirds of the crew members are a manufacturer’s authorized furniture installer capable of the job requirements of the final approved installation drawing.

5.5.1.1. Installation shall be coordinated with the FAA/ Construction schedule.

5.5.2. Furniture Contractor shall be required to provide the necessary personnel to accomplish the installation in accordance with the project schedule.

5.5.3. Clean up. At the conclusion of each installation, the Furniture Contractor shall:

5.5.3.1. Clean in accordance with manufacturer’s recommendations, and prepare the furniture ready for use, and vacuum clean the installation site.

5.5.3.2. Remove all trash and packing materials from the installation site, and remove from the MMAC premises.

5.5.3.2.1. Cardboard Recycling. The Furniture Contractor shall be responsible for separating recyclable cardboard from other packing materials and the appropriate removal and disposal in the cardboard recycling container located at Building 50. No cardboard may be disposed of in ANY

015-BMB Renovation 4

AMP-100, AMP-300, & AMP-400

WASTE CONTAINER at the MMAC other than a CARDBOARD

RECYCLING CONTAINER.

5.5.4. Inspection.

5.5.4.1. At the completion of each phase, the Furniture Contractor’s Project

Manager, Furniture Installer and the FAA shall inspect all components to ensure that the installation is complete and that the furniture is free of defects and ready for use.

5.5.4.2. Furniture Contractor shall repair all defects or replace damaged components in a timely manner to the satisfaction of the FAA.

5.6. Training.

5.6.1. Furniture Contractor shall provide training to FAA personnel on installing, reconfiguring and maintaining the product.

6. GENERAL REQUIREMENTS:

6.1. General. Furniture components shall have similar construction and appearance, and ability to be integrated in the workspace.

6.2. Accessibility. All components and design shall meet ADA and ABA (UFAS) guidelines.

6.3. ANSI/BIFMA - All furniture components shall comply with the applicable ANSI/BIFMA

Standards.

6.4. Durability. All products furnished under this description shall be of a design and materials to withstand hard daily use with a minimum of maintenance and repair.

6.5. Assembly. No special tools shall be required for assembly and/or disassembly of work surfaces, overheads and components.

6.6. Product Brochure. A manufacturer’s brochure(s) with color photographs of ALL the proposed furniture products shall be provided with bid package.

6.7. Product Specifications. A manufacturer’s detailed product specification to determine compliance with FAA specifications shall be provided with bid package.

6.8. Warranty. A manufacturer’s minimum 10-year product warranty (excluding fabrics and lighting) shall be provided with bid package.

6.9. Availability. A manufacturer’s written guarantee of availability of components compatible with the original installation for a period of not less than five (5) years shall be provided with bid package.

6.10. Environmental Aspects. Provide manufacturer’s information with bid package:

6.10.1. Recycled Content. Amount of recycled content.

6.10.2. Recyclable. Amount of post-consumer recyclable materials.

6.10.3. Air Quality Certification. Emission standards for off-gassing of product components.

6.10.4. LEED Eligibility. Identification of LEED eligible products.

6.11. Product Colors. Furniture Contractor shall select products that provide the following minimum color choices. Provide samples with bid package.

6.11.1. Systems Furniture, Benching systems, & Private Office Furniture:

6.11.1.1. Trim Colors – minimum five (5), pricing shall be based on metallic finishes

6.11.1.2. Laminate Colors – minimum six (6) solids and six (6) wood-grains with matching wood grain PVC or ABS plastic edge

6.11.1.3. Overhead Cabinet Glazing – back painted glass with a minimum two (2) colors.

6.11.1.4. Fabric Tiles - minimum five (5) patterns with six (6) colors, pricing shall be based on Grade 1 fabrics.

6.11.1.5. Storage Seat Cushion- minimum of five (5) patterns with six (6) colors, pricing shall be based on Grade 4 fabrics.

6.11.2. Architectural Wall System:

015-BMB Renovation 5

AMP-100, AMP-300, & AMP-400

6.11.2.1. Trim Colors – minimum five (5), pricing shall be based on metallic finishes

6.11.2.2. Metal Skins- minimum of six (6) colors

6.11.2.3. Glazing – Clear, Frosted Glass or back painted glass with a minimum two

(2) patterns/colors.

6.11.3. Banquette Seating & Lounge furniture

6.11.3.1. Laminate colors – minimum six (6) woodgrains with matching PVC or ABS plastic edge

6.11.3.2. Wood Veneer – minimum six (6) woodgrains

6.11.3.3. Upholstery – minimum five (5) patterns with six (6) colors, pricing shall be based on Grades 5 & 6.

POWERED SYSTEM FURNITURE: Typicals “2A, 2AS, 2B, 3A, 4AAS, 4BB, 4BBS, 6A, 6AA, 6AB, & 6BB & K”

7. SYSTEMS FURN - PANEL FRAMES, PANEL FACES, & PANEL INSERTS:

7.1. Product Quality & Aesthetics: Steel frame (factory baked-enamel finish) with tiled acoustical panel appearance.

7.2. Dimensions. Panels shall be available in +/- 66” high and widths capable of configuring typicals in the space provided. Panel widths must be available in 6” increments between the widths of 24” and 60”.

7.3. Panel Frame. Frames shall be constructed so as to accept side-supported cantilevered lower and upper components or freestanding components.

7.4. Panel Thickness. Frames (with panel faces attached) shall be 3 inches thick.

7.5. Panel Door. Doors shall be surface mount, glazed sliding door 36” wide x +/- 66” tall doors shall be provided as shown on the Typical “2AS” Door frame shall match panel frame finish.

7.6. Panel Face. Panel faces shall be removable from the frame without disassembly of the workstation. All panel faces shall be TILED and have a minimum of two (2) tiles per panel frame. NOTE typical Lower tile shall be approximately 30” tall, and upper tile shall be approximately 36” tall. The following panel face finishes shall be provided as indicated on the typicals:

7.6.1. Fabric Covered Tackable Acoustic Tiles: All fabric panel faces shall be 100% synthetic fabric, have a Class “A” fire rating and be tackable.

7.6.2. Acoustics. All face panels, shall have full height acoustical material on both sides of the panel unless specified otherwise (examples may be decorative laminate, wood or metal accent panel, or marker board insert).

7.6.3. Installation. Straight, level and close all gaps to within 1/8”. Fabric panels are taut. Patterns are level and shall not appear stretched, wavy or distorted.

7.6.4. Glazed. Stack-on style, center mount frameless glazed panel +/- 12” high.

7.7. Panel Connections. Furniture systems shall be capable of connecting in a variety of configurations. Panel based systems shall allow for the connection of panels of differing heights and the connection of two, three or four panels from a single point.

7.7.1. The connector system shall provide tight connections, which provide continuous visual and acoustical seals.

7.7.2. Each junction shall have an extruded metal top cover that shall match finish and color of the panel trim and shall be level with the panel top rail.

7.7.3. The connector system shall provide, as required, for the continuation of power and data wiring within workstations and from workstation to workstation.

7.8. Component Mounting. Panel based systems shall provide for the mounting of components at varying heights on both sides of the panel. Furniture systems not based

015-BMB Renovation 6

AMP-100, AMP-300, & AMP-400

on structural panels must allow for the support of overhead cabinets, shelves, work surfaces, task lighting, and paper management.

7.8.1. Accessories.

7.8.1.1. Marker Board. Each work station shall have a minimum of one 36X48 glazed dry erase board panel skins, refer to typicals for quantities

7.8.1.2. Tool Rail Panels. Tool rails and compatible tool rail components must be available in standard product offering. Each typical work station requiring tool rails shall have a minimum of 12” minimum height tool rail installed above work surface.

7.8.1.3. Tool Rail Accessories.

7.8.1.3.1. Display Tray Each work station shall be provided with one tool rail mounted display tray.

7.8.1.3.2. Sorting Tray. Each work station shall be provided with one tool rail mounted folder tray.

7.9. Leveling and alignment. The system shall provide precise alignment of adjacent panels and /or components and shall include leveling guides to compensate for uneven floors.

A minimum of .8 inches (20mm) adjustment range is required. When placed on a level surface with the glides fully retracted the maximum distance between the panel and the floor shall be 1 inch (25mm).

8. SYSTEMS FURN - POWER AND DATA DISTRIBUTION:

8.1. Power and Data. Panels shall have a system capable of distributing power service and data service to multiple workstations through separate feed points.

8.1.1. Base Feed: Power & Data must be capable of entering the furniture by the following methods:

8.1.1.1.1. Power & Data feeds may be through separate junction boxes in wall located behind panels. Note: panels against wall shall be omitted.

8.1.1.1.2. Power & Data Feeds may be through separate junction boxes located in concrete slab.

8.1.1.1.3. Power & Data feeds may be through systems furniture furnished power/data poles. Note: power & data may not be run through a shared pole unless it is a divided and properly shielded power pole.

8.1.2. Distribution:

8.1.2.1. Access to the power and data distribution system inside panels shall be easily made and without tools.

8.1.2.2. Power and data must be separated by a minimum of 24” at all points within the panel and feeds. The power and data cables shall NOT cross each other. NOTE: Power wire harnesses that are constructed of shielded flexible metal conduit are not required to maintain 24” separation

8.1.3. Power System. Power/Data panels shall include an electrical system that is UL rated and meets all current National Electrical Code (NFPA 70) requirements. A minimum 8-wire, 3-circuit system (with minimum 20-amp 125 volts per circuit capacity) and minimum #12 AWG wire size shall be used. NOTE: 10 wire, 4 circuit system may be substituted, provided separate neutrals are provided for each circuit.

8.1.3.1. The power wiring system must provide a separate and unique neutral conductor per circuit (i.e.: 3 circuits, 3 neutrals, and 2 grounds minimum).

8.1.3.2. Each 3-3-2 power wiring system shall serve a maximum of six (6) workstations. Ideally no circuit should serve more than two (2) workstations/areas.

8.1.3.3. To the maximum extent possible, circuits shall be designed so that all receptacles within a workstation are on the SAME circuit.

015-BMB Renovation 7

AMP-100, AMP-300, & AMP-400

8.1.3.4. Knockout plates capable of accepting duplex receptacles (20 amp 125 volt capacity) shall be provided in all identified powered panels.

8.1.3.5. Duplex receptacles shall be provided as shown on the typical. Power outlets shall be 20 amps duplex (NEMA 5-20R). Each duplex outlet shall have a label that identifies the phase of the circuit to which it is connected. Power wiring system should have the capability of having the outlets installed back-to-back.

8.1.3.6. The power wiring harness system shall be located in or near the base of the panels.

8.1.3.7. The wiring harness system shall be enclosed in flexible metal conduit.

8.1.4. Data Cable Management. Power/Data panels shall have a data channel that is properly separated OR shielded from electrical sources. Data channels shall be accessible without removing panel hung components. Panels shall offer the following capacities for routing data cables.

8.1.4.1.1. NOTE: Data may be run inside the furniture panel cavity provided power and data maintain a 24” separation or shielding AND the panel faces are tiled and removable without removing panel hung storage components or work surfaces.

8.1.4.2. Furniture vendors shall provide flush mounted faceplates, bezel and blank covers capable of accepting standard Aeronautical Center data receptacles.

8.1.4.2.1. Knockout plates in the panel face shall be capable of providing a minimum of 3 potential jacks per workstation. Data faceplates must be capable of three (3) RJ45 Systimax, Part # MGS400BH-112 (ORANGE) at each location shown

8.1.5. Data outlets can be installed without damage to the panel face.

9. SYSTEMS FURN - PANEL HUNG WORK SURFACES:

9.1. Types. Furniture system shall include work surfaces, which are panel/system supported and/or freestanding. When panel/system supported and freestanding surfaces are offered, they shall be of similar construction and appearance and shall allow the integration of both types within a workstation. Panel/system supported surfaces may include cantilever, rail, bracket and end supported.

9.2. Construction. Shall be a minimum of 1” thick, 40-50# density particle board with a high-pressure laminate. Surfaces shall be balanced to resist warping, and underside shall be smoothly finished. Abutting work surfaces shall meet at equal heights when used in side-by-side or side-to-end configuration in order to provide a continuous and level work surface.

9.3. Dimensions. The system shall include work surface depths of 24, 30, and 36 inch and widths between 24 inch and 96 inch (1525 mm) in 6-inch increments. Work surfaces 72 inches and longer will require additional supports.

9.4. End Panels. Full height end panels shall be provided on ends of work surfaces where visible. Product line should also offer solid panel, metal leg support and decorative architectural panel support as optional features.

9.5. Cable management. Panel hung Work surfaces shall have a continuous reveal at back edge approximately 1” wide to permit the passage of power & equipment cables where the surface meets the panel.

9.5.1. In lieu of a continuous reveal, scalloped edges or unobstructed color coordinated grommets may be provided in the following quantities:

9.5.1.1. Work surfaces less than 48 inches – minimum of one (1)

9.5.1.2. Work surfaces 48 inches or more - minimum of two (2)

015-BMB Renovation 8

AMP-100, AMP-300, & AMP-400

10. ADJUSTABLE HEIGHT LAMINATE TOP (SIT-TO STAND) DESK WITH WIRE

MANAGEMENT:

10.1. Types. Rectangular REFER TO TYPICALS for requirements.

10.2. Tops. Shall be a minimum of 1” thick, 40-50# density particle board with a high-pressure laminate. Surfaces shall be balanced to resist warping, and underside shall be smoothly finished. NOTE: Work surface tops must be slightly smaller than specified to ensure clear fit between system furniture panels and storage components.

10.2.1. Edge. All edges shall be ABS or PVC plastic (softened rim) in finish to match plastic laminate.

10.3. Base. Bases shall be an electric, height-adjustable, with metal column legs, providing a tabletop height of ± 22” – ± 47” high, controlled by a central control box for synchronization. Column legs must be precision balanced to minimize surface vibrations.

10.3.1. Finish. Metallic shall be included in bid price.

10.3.2. Construction: Distributed weight capacity must be minimum of 250 pounds

10.3.3. Cable management: Telescoping leg shall provide a vertical race way that permits the power cords & network patch cords to route below the table, down one leg to base raceway mounted system furniture power & network outlets.

10.3.4. Leveling: Leveling glides must be capable of adjusting ½” to accommodate uneven floors.

10.4. Wire Management System. Table must have an integrated cable management below the table that permits the power, network cords to route below the table, down one leg to base raceway mounted system furniture power outlet

10.4.1. Vertical Cable Carrier Flexible cable management conduit to conceal and protect power and data wire management from table surface to floor. Cable carrier must be a minimum of 48” long.

10.5. Power System. An electrical system shall be provided that is UL rated and meets all current National Electrical Code (NFPA 70) requirements.

10.5.1. Controller: Touch device that allows user to adjust the surface height of the desk at a rate of approximately 1-1/2” per second by simply pushing the up and down arrows. Controller must be capable of being placed on either right or left side of desk.

10.5.2. Power Cord Minimum 9’ length cord with 15 amp duplex plug shall be located below the table that permits the power to route down and plug into floor or wall mounted building power outlets.

10.5.3. Power & Data Strip. Each sit-to-stand work surface shall be provided with one 8’ power with cord & work surface edge mounted attachment.

10.6. Construction. Designed for commercial office use.

11. LOW STORAGE TYPE 1: Typicals “2A, 2AS, 3A, 4AAS, 6A, 6AA, & 6AB

11.1. Low Storage. Furniture products shall include a low storage unit, style to coordinate with systems furniture workstations, for use only on 6X8 work stations

11.1.1. Common Top. Approximately 18” deep and 1-1/8” thick constructed of wood substrate with high pressure plastic laminate finish with matching ABS edge. Top must be notched and finished with plastic grommet to accommodate wire management and leg for sit-to-stand work surface lift.

11.1.2. 1.5 High Drawers. One 36” wide (1) locking lateral file drawer and one (1) locking box drawer above. Drawers shall be centered in the unit.

11.1.3. 1.5 High storage shelves. Open shelving with one adjustable shelf.

11.1.4. 1 High Storage Shelves. Open shelving shall be approximately 16” high and have approximately 10.5” usable depth with removable back panel for access to outlets behind storage unit.

015-BMB Renovation 9

AMP-100, AMP-300, & AMP-400

11.1.5. Cushion Top. Lateral file unit shall have a fabric upholstered cushion top for guest seating.

11.1.6. Base. 3” high plinth base or architectural leg with leveling glides adjustable to +/- 3/4”

11.1.7. All surfaces shall be finished.

11.1.8. Construction. Components may be constructed of steel with factory-baked enamel finish or wood substrate with high pressure plastic laminate finish and designed for commercial office use

12. LOW STORAGE TYPE 2: TYPICAL “K” RESPITE AREA

12.1. Low Storage. Furniture products shall include a low storage unit, style to coordinate with systems furniture workstations.

12.1.1. Common Top. Approximately 18” deep and 1-1/8” thick constructed of wood substrate with high pressure plastic laminate finish with matching ABS edge. Top must be notched and finished with plastic grommet to accommodate wire management and leg for sit-to-stand work surface lift.

12.1.2. 1 High Drawers. One 36” wide (1) locking lateral file drawer

12.1.3. 1 High Storage Shelves. Open shelving shall be approximately 16” high and have approximately 10.5” usable depth with removable back panel for access to outlets behind storage unit.

12.1.4. Cushion Top. Lateral file unit shall have a fabric upholstered cushion top for guest seating.

12.1.5. Base. 3” high plinth base or architectural leg with leveling glides adjustable to +/- 3/4”

12.1.6. All surfaces shall be finished.

12.1.7. Construction. Components may be constructed of steel with factory-baked enamel finish or wood substrate with high pressure plastic laminate finish and designed for commercial office use

13. PEDESTALS AND DRAWERS:

13.1. Types. Furniture products shall include mobile and/or freestanding drawer pedestals

13.2. Drawer pedestals must have designer metal pull handles such as a bar pull or similar.

13.2.1. Cushion Top. Mobile pedestals shall have a fabric upholstered cushion top for guest seating.

13.2.2. Drawers. Pedestals shall be provided in the various drawer combinations as shown on the typical and shall be locking.

13.2.2.1. Pencil Tray. A minimum of one (1) shall be provided with each Box/File pedestal.

13.2.2.2. Box drawers. Shall be a minimum of four (4) inches deep and shall have one removable divider.

13.2.2.3. File drawers. File drawers shall have a minimum inside dimension of 12” wide X 9.5” tall and integral rail with adequate clearance to accommodate letter size hanging folders with tabs. File drawers shall have full extension ball bearing suspensions.

13.3. Glides. Drawers shall have heavy duty bearing glides. All drawer suspension shall be constructed so as to not expose the user to grease or sharp edges.

13.4. Construction. Components may be constructed of steel with factory-baked enamel finish and designed for commercial office use

14. SYSTEM FURNITURE OVERHEAD COMPONENTS – PANEL HUNG

14.1. Types. Furniture system shall include open and closed shelving as shown on the typicals in various widths to match work surfaces

015-BMB Renovation 10

AMP-100, AMP-300, & AMP-400

14.1.1. Overhead undersides shall have the same finish and color as the face/end support.

14.2. Doors. Lockable closed shelving shall be provided with a door constructed of a glazed panel with metal trim. Doors may be hinged, sliding, flip up & over, or flip up & receding.

14.2.1. Glazing. Back-painted glass or frosted glazing shall be available.

14.3. Dimensions. Interior of closed units and shelves shall accommodate a minimum of 12” deep by 12” tall objects.

14.4. Accessories. A minimum of one (1) steel shelf divider per linear foot shall be provided for each shelf and upper storage component.

14.5. Construction. Components may be constructed of steel with factory-baked enamel finish or wood substrate with high pressure plastic laminate finish and designed for commercial office use

15. PERSONAL STORAGE CABINETS:

15.1. Storage Cabinet. Furniture products shall include a closed lockable combination metal storage cabinet, style to coordinate with systems furniture workstations.

15.1.1. One side shall have a full height locking hinged door with coat rod and one (1) fixed shelf.

15.1.2. One side shall have two locking (2) box drawers and one locking (1) file drawer on the bottom and a partial height locking door with adjustable shelves on the top.

15.1.3. All surfaces shall be finished.

15.1.4. Construction. Components shall be constructed of steel with factory-baked enamel finish and designed for commercial office use

ARCHITECTURAL WALLS: Typicals “AW-1, AW-2, AW-3, AW-

4, & AW-5”

16. ARCHITECTRUAL WALLS - PANELS, PANEL FACES, & DOORS:

16.1. Product Quality & Aesthetics: Architectural walls may be either Unitized (factory built-fully assembled panels for tilt-in installation) OR Demountable (components arrive and are assembled on site) and have a reveal design with vertical slotting for wall hung furniture components.

16.2. Panel Dimensions. Architectural wall panels shall be floor to ceiling design, capable of ceiling heights up to 9’ high and panel widths must be able to accommodate proposed design. Panels must be stackable to accommodate ceiling height changes and panel type changes. Frames (with panel faces attached) shall not exceed 4 inches thick,

16.3. Panel Face. Panel faces (skins) shall be removable from the frame and interchangeable in the field without disassembly of the complete unit. Solid walls skins shall be constructed of 22 gauge steel skins, gypsum board panel faces will NOT be considered. The following panel face finishes shall be available, refer to typicals for project requirements:

16.3.1. Metal Skins: A metal skins shall be factory finished powder coated steel, available in choice of finish including marker board finish.

16.3.2. Captured Glass Frame: Glazed frame assemblies shall be constructed of ¼” tempered glass and accommodate single or double glazed configurations (refer to typical drawings). Frames shall be pre-glazed prior to arriving at site and shall be constructed of extruded aluminum, and either powder coated paint or clear anodized as required by finish schedule.

16.3.2.1. Note: Solid Skin panels shall be interchangeable with glass frame panels of equal sizes and vice versa.

16.4. Panel Connections & Framing Components: Architectural wall systems shall be capable of connecting in a variety of configurations. Panel based systems shall allow

015-BMB Renovation 11

AMP-100, AMP-300, & AMP-400

for the connection of panels with different panel face finishes and the connection of two, three or four panels from a single point.

16.4.1. The connector system shall provide tight connections, which provide continuous visual and acoustical seals.

16.4.2. Each junction shall have an extruded metal cover that shall match finish and color of the panel trim.

16.4.3. The connector system shall provide, as required, for the continuation of power and data wiring within panels.

16.4.4. End fillers for Architectural wall adjacent to fixed walls and columns shall be similar in construction to solid wall skins and fit into end channel on abutting wall.

16.4.5. Ceiling track shall be one piece continuous formed steel and shall be capable of being installed to the underside of suspended ceilings without using destructive fasteners.

16.4.6. Floor track shall be one piece continuous formed steel and shall be capable of being installed on hard floor surfaces and carpeted flooring without the use of mechanical fasteners.

16.5. Doors. Architectural wall system shall be capable of providing the following door types:

16.5.1. Slide Doors: Slide doors shall be fully supported by wall structure without requiring additional structural support from other architectural elements. Doors shall include fascia, header and track, finished opening frame and sliding door. Roller assemblies shall be constructed of steel with high quality ball bearing wheels and include pneumatic braking mechanism.

16.5.2. Frame: Door frame shall be formed steel and aluminum and shall include continuous resilient sound seal at top and side jambs. Frame shall be capable of providing vertical adjustment to compensate for floor and ceiling irregularities without the need to cut the doors on site.

16.5.2.1. KEYING: (Stanley/Best 1E Mortise Cylinder with Best 7-pin construction core) in finish 626.

16.5.3. Door leaves: Doors shall be pre-finished and leafs shall be available in the following options:

16.5.3.1.1. 3/8” tempered glass (frameless) fully glazed.

16.6. Leveling and alignment. The system shall provide precise alignment of adjacent panels and shall provide a 3” vertical adjustment (+/- 1-1/2”) in overall height to compensate for uneven floors and ceiling irregularities.

16.7. Sound attenuation: Solid and framed glass systems must be in compliance with ASTM E 72 “standard test methods of conducting strength tests of panels for building construction”

16.7.1. Steel Clad Skins: Wall with steel clad skins must meet a minimum 42 STC without field added insulation or gaskets.

16.7.2. Glazed Walls: Single glazed walls must meet a minimum of 30 STC with ¼” glass.

17. ARCHITECTURAL WALL - POWER AND DATA DISTRIBUTION:

17.1. Power and Data. Panels shall have a system capable of distributing power service and data service to multiple workstations through separate feed points.

17.1.1. Base Feed: Power & Data must be capable of entering the wall by the following methods:

17.1.1.1.1. Power & Data feeds may be through ceiling junction boxes. Note:

power & data may not be run adjacent through the same panel unless it is either separated by a minimum of 24” or in flexible metal conduit and properly shielded.

015-BMB Renovation 12

AMP-100, AMP-300, & AMP-400

17.1.2. Distribution:

17.1.2.1. Access to the power and data distribution system inside panels shall be easily made.

17.1.2.2. Power and data must be separated by a minimum of 24” at all points within the panel and feeds. The power and data cables shall NOT cross each other. NOTE: Power wire harnesses that are constructed of shielded flexible metal conduit are not required to maintain 24” separation

17.1.3. Power System. Power/Data panels shall include an electrical system that is UL rated and meets all current National Electrical Code (NFPA 70) requirements. A minimum 8-wire, 3-circuit system (with minimum 20-amp 125 volts per circuit capacity) and minimum #12 AWG wire size shall be used. NOTE: 10 wire, 4 circuit system may be substituted, provided separate neutrals are provided for each circuit.

17.1.3.1. The power wiring system must provide a separate and unique neutral conductor per circuit (i.e.: 3 circuits, 3 neutrals, and 2 grounds minimum).

17.1.3.2. Each 3-3-2 power wiring system shall serve a maximum of six (6) workstations. Ideally no circuit should serve more than two (2) workstations/areas.

17.1.3.3. To the maximum extent possible, circuits shall be designed so that all receptacles within a workstation are on the SAME circuit.

17.1.3.4. Knockout plates capable of accepting duplex receptacles (20 amp 125 volt capacity) shall be provided in all identified powered panels.

17.1.3.5. Duplex receptacles shall be provided as shown on the typical. Power outlets shall be 20 amps duplex (NEMA 5-20R). Each duplex outlet shall have a label that identifies the phase of the circuit to which it is connected. Power wiring system should have the capability of having the outlets installed back-to-back.

17.1.3.6. The power wiring harness system shall be located in or near the base of the panels.

17.1.3.7. The wiring harness system shall be enclosed in flexible metal conduit.

17.1.4. Data Cable Management. Power/Data panels shall have a data channel that is properly separated OR shielded from electrical sources. Panels shall offer the following capacities for routing data cables.

17.1.4.1. Furniture vendors shall provide flush mounted faceplates, bezel and blank covers capable of accepting standard Aeronautical Center data receptacles.

17.1.4.1.1. Knockout plates in the panel face shall be capable of providing a minimum of 3 potential jacks per workstation. Data faceplates must be capable of three (3) RJ45 Systimax, Part # MGS400BH-112 (ORANGE) at each location shown

17.1.5. Data outlets can be installed without damage to the panel face.

18. POWERED CONFERENCE TABLES & BENCHING

SYSTEM: Typicals “C1, C2, C3, & E”

19. PLASTIC LAMINATE CONFERENCE TABLE: Typicals C1-C2

19.1. Product Quality & Aesthetics. Refer to images provided on typicals

19.2. Tops. Table top shall be plastic laminate over wood substrate with a matching wood grain PVC or ABS edge approximately 1 ¼” thick with a modern design.

19.2.1. Cutouts. Work surface tops shall have linear cut outs for power/data module access doors centered on the work surface

015-BMB Renovation 13

AMP-100, AMP-300, & AMP-400

19.3. Wire Management: Tables must provide a path for power and network from Power Modules to below the table in a race way that permits the power to route through the table, down the hollow base and into floor mounted building power connections.

19.4. Architectural Base Typical C1 Polished metal shall have a modern architectural style and shall be hollow for wire management, refer to photo on typical for design intent.

19.5. Panel Base Typicals C2 Bases shall be plastic laminate on wood substrate or have a combination of metal and plastic laminate designer features. Provide a minimum of 27” high clearance. Bases shall be hollow for wire management & equipped with a removable or hinged panel for access.

20. COLLABORATIVE TABLE WITH MONITOR WALL – Typical “C3”

20.1. Tops. Shall have high pressure plastic laminate over wood substrate with PVC or ABS plastic edge approximately 1 1/8 thick or other acceptable heavy-duty design.

20.2. Base. Metal or wood base shall provide a minimum of 27” high knee clearance.

Bases shall be integrated into the table & media wall design and serve as a wire management path from the table to the media wall.

20.3. Monitor Wall. Monitor mount wall that provides a convenient and attractive means of mounting monitors and is either mounted or integrated into conference table (not wall mounted) and have vertical wire management path for monitor. May be constructed of high pressure plastic laminate over wood substrate w/ metal accents, aluminum or steel with factory-backed enamel finish, offered in colors to match other exposed metal table components, and designed for commercial office use.

20.4. Cameral shelf. Shelf or ledge that mounts to monitor wall, may be constructed of high pressure plastic laminate over wood substrate, aluminum or steel with factory-backed enamel finish, offered in colors to match exposed metal table components.

20.5. Wire Management System. Table must have an integrated cable track below the table that permits the power, network and A/V cords to route through the table from the power/data module to the monitor wall and also to the building’s electrical systems.

20.6. Construction. All exposed surfaces must be finished and designed for commercial office use.

21. BENCHING SYSTEM: TYPICAL “E”

21.1. Product Quality & Aesthetics. Benching system constructed of dual-sided base units

(with work surfaces) with an integrated rail frame system with intermediate support legs.

Bench system shall be capable of 6-pack units that shall be equal the total length and width required by typical.

21.2. Tops. Shall be a minimum of 1” thick, 40-50# density wood substrate with a high-pressure laminate. Surfaces shall be balanced to resist warping, and underside shall be smoothly finished. Refer to typicals for work surface dimensions.

21.2.1. Cutouts. Work surface tops shall have linear cut outs for power/data module access doors centered on the work surface

21.3. Wire Management: Metal wire management tray shall be integrated into the frame system, located below the work surfaces for power and separate data wire management tray or cable hangars mechanically attached to the underside of the work surfaces or frame.

21.3.1. Edge. All edges shall be ABS or PVC plastic (softened rim) in finish to match plastic laminate.

21.3.2. Privacy Screen. Benching system shall have a partial height privacy screens extending the full width of the work surface and extend approximately 18” above work surface.

015-BMB Renovation 14

AMP-100, AMP-300, & AMP-400

21.3.2.1. Hardware. Privacy screens shall have surface-mounted hardware that mechanically fastens to the center rail structure.

21.3.2.2. Construction: Privacy screens may be constructed of fabric covered acoustical panels, glazed panel, or metal tool rail panel.

21.4. Base. Bases shall be constructed of metal frame providing a tabletop height of +/- 29” high. Base shall have center rail metal frame systems with intermediate legs (or bases) that allow for extensions for up to 32’ in total length.

21.4.1. Finish. Metallic shall be included in bid price.

22. POWER & NETWORK SYSTEMS:

22.1.1. Power System. Conference tables C1, C2, C3 & Bench system Typical E shall include an electrical system that is UL rated and meets all current National Electrical Code (NFPA 70) requirements.

22.1.1.1. Wire Harness. For use on Typical E A minimum 8-wire, 3-circuit system (with minimum 20-amp 125 volts per circuit capacity) and minimum #12 AWG wire size shall be used.

22.1.1.2. The power wiring system must provide a separate and unique neutral conductor per circuit (i.e.: 3 circuits, 3 neutrals, and 2 grounds minimum).

22.1.1.3. Each 3-3-2 power wiring system shall serve a maximum of eight (8) workstations.

22.1.1.4. The wiring harness system shall be enclosed in flexible metal conduit or liquid-tight conduit. Power harness shall run in a cable tray that permits the power to route beneath the work surfaces, down the base and into floor mounted j-box and hard wired into the building’s power connections.

22.1.2. Power Data Module Type-1. Refer to Typical E for quantities: Each Module shall have the following:

Minimum of two (2) duplex outlets (or 4 simplex outlets), two (2) RJ-45 connections Power Data Module Type-2: Typicals C1, C3 & C3 power modules must have a minimum of one (1) duplex outlet (or 2 simplex outlets), one (1) AV faceplate with one (1) RJ-45 connections and at least two (2) additional blank plates for future use.

NOTE: Blank AV faceplates must be capable of connecting one (1) VGA, one

(1) Audio outlet, and one (1) HDMI in.

22.1.3. Each power module shall contain a 8’-10’ long Direct Plug-In 15 amp power cord.

22.1.4. All Power modules MUST provide a slotted opening for cord passage when hinged door is in closed position.

22.1.5. Data Cable Management. Data wire management tray or cable hangars mechanically attached to the underside of the work surfaces or frame that permits the data cables to be routed from a j-box below the raised floor, through the benching system base and terminated in the power/data matrix.

22.1.5.1. Furniture vendors shall provide flush mounted faceplates, bezel and blank covers capable of accepting standard Aeronautical Center data receptacles.

22.1.5.1.1. Knockout plates in the power/data matrix shall be capable of providing a minimum of 2 potential jacks per position & must be capable of accepting RJ45 Systimax, Part # MGS400BH-112 (ORANGE) at each location shown.

22.1.6. Finish and design features shall coordinate with the table.

Construction. Designed for commercial office use.

015-BMB Renovation 15

AMP-100, AMP-300, & AMP-400

MANAGER & OA WORK STATIONS: Typicals “D1, D2, D3 & D4”

23. STYLE:

23.1. Modern Plastic Laminate Furniture –Shall have wood grain plastic laminate over wood substrate with a modern edge. Overheads shall have glazed doors with metal trim.

Fabric tack boards shall be provided between overheads and work surface. Full-height cabinets shall have wood grain plastic laminate doors. Hardware shall be silver colored modern style (such as a metal linear bar or other designer hardware).

24. PLASTIC LAMINATE CONTRACTOR OFFICE DESK: Typical D1

24.1. Style. Overall style of furniture shall be modern and similar in style to images provided on typical.

24.2. Tops. Shall have a rectangular top constructed of plastic laminate over wood substrate with a matching pvc edge

24.3. End panels. Where visible provide metal architectural support panel.

24.4. Modesty Panels:

24.4.1. Front modesty panels shall be partial height, glazed or metal suspended below work surface

25. PLASTIC LAMINATE MANAGER OFFICE DESK: Typical D2

25.1. Style. Overall style of furniture shall be modern and similar in style to images provided on typical.

25.2. Tops. Shall may be rectangular top with radius end or other specialty shape designed to encourage meetings. constructed of plastic laminate over wood substrate with a matching pvc edge

25.3. End Panels/Support Post. Where visible provide metal architectural support panel or tubular post.

25.4. Modesty Panels:

25.4.1. Front modesty panels shall be partial height, glazed or metal suspended below work surface

26. PLASTIC LAMINATE RECEPTION WORKSTATION: Typical D3

26.1. Style. Overall style of furniture shall be modern and similar in style to images provided on typical.

26.2. Tops. Shall have plastic laminate over wood substrate with a matching pvc edge.

26.3. Designer Front Panels. Reception height wood grain laminate privacy panels 36-42” high, depending on transaction top thickness, with accent panel of different material such as frosted glazing, metal, or other modern accent finish.

26.4. Transaction Top. Glazed or other accent material transaction top shall appear to be “floating” above privacy panels with a reveal, metal stand-off, or other designer element.

26.5. Pedestals and drawers. Plastic laminate pedestal shall be provided as shown.

Drawers shall be lockable.

26.5.1. Drawers. Mobile pedestals shall be locking and provide the following.

26.5.2. Pencil Tray. A minimum of one (1) shall be provided with each Box/File pedestal.

26.5.3. Box drawers. Shall be a minimum of four (4) inches deep and shall have one removable divider.

26.5.4. File drawers. File drawers shall have a minimum inside dimension of 12” wide X

9.5” tall and integral rail with adequate clearance to accommodate letter size

015-BMB Renovation 16

AMP-100, AMP-300, & AMP-400

hanging folders with tabs. File drawers shall have full extension ball bearing suspensions.

26.6. Construction. All exposed surfaces shall be constructed of plastic laminate over wood substrate with glazed and metal accents to coordinate.

27. ADJUSTABLE HEIGHT (SIT-TO STAND) LAMINATE TOP DESK/RETURN Typicals D1, D2, D3, & D4

27.1. Tops. Shall be a minimum of 1” thick, 40-50# density particle board with a high-pressure laminate. Surfaces shall be balanced to resist warping, and underside shall be smoothly finished.

27.1.1. Edge. All edges shall be ABS or PVC plastic (softened rim) in finish to match plastic laminate.

27.2. Base. Base shall contain an integrated electric, height-adjustable work surface top with total height adjustment of ± 29” – ± 42” high, controlled by a central control box for synchronization. Column legs must be precision balanced to minimize surface vibrations.

27.2.1. Construction: Distributed weight capacity must be minimum of 200 pounds

27.2.2. Cable management: Telescoping leg shall provide a vertical race way that permits the power cords & network patch cords to route below the table, down one leg to wall power outlets.

27.2.3. Leveling: Leveling glides must be capable of adjusting ½” to accommodate uneven floors.

27.3. Wire Management System. Table must have an integrated cable management below the table that permits the power, network cords to route below the…