1375_South_Lake_Road_.pdf

PDF 209 KB Posted

Attached to
Roof Repairs and Replacement Due to Hurricane Damage
Solicitation number
2025-059
Issued by
Polk County, Florida

About this file

This document is a roofing project specification sheet for a building, likely prepared by St. Cloud Builders, detailing a comprehensive roof replacement and repair project. The scope of work includes demolition of existing metal roofing on the front porch and removal of four roof vents, followed by new construction involving the installation of 5V crimp galvanized steel 29-gauge roof panels over existing shingles, with 1x4 wood strips placed at 24-inch intervals. Additional work includes repairing roof decking where vents were removed, installing two layers of 15# felt over new decking, and implementing a new galvanized steel ridge vent along the full ridge length.

The project specifications emphasize contractor responsibilities such as verifying all roof slopes and dimensions prior to commencing work, performing all tasks in a professional manner, and ensuring thorough cleanup including nail removal from the ground surrounding the building. The contractor is also required to dispose of all removed materials safely and legally. The drawings include detailed plans showing existing and proposed roof configurations, front and side elevation views, and specific technical notes about installation requirements and materials. The document is dated 01/24/25 and includes a scale of 1/4" = 1'-0" for precise measurements and planning.

View the file

Other files

File Type Posted
Roof_Repairs_and_Replacement_Due_to_Hurricane_Damage.pdf PDF
1375_South_Lake_Road_.pdf PDF
3101_Progress_Lane_.pdf PDF
Attachment_B_-_Federal_Requirements.pdf PDF
Sample_Agreement.docx DOCX document

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

'-0

30'-0"

'-4

26'-8"

SLOPE

8:12

S

LO

PE

:1

SLOPE

8:12

2'-0"2'-0"

'-6

26'-0"

EXISTING SHINGLE

ROOFING TO REMAIN

EXISTING ROOF VENTS TO BE

REMOVED AND HOLE ROOF

DECKING REPAIRED (TYP OF 4)

EXISTING 5V CRIMP

GALVANIZED STEEL

29-GAUGE ROOFING TO

BE REMOVED"

'-0

30'-0"

'-4

26'-8"

SLOPE

8:12

S

LO

PE

:1

SLOPE

8:12

2'-0"2'-0"

'-6

26'-0"

5V CRIMP GALVANIZED STEEL

29-GAUGE ROOFING OVER 1x4

WOOD STRIPS @ 24" O.C. OVER

EXISTING SHINGLE ROOF

CONTINUES RIDGE VENT

5V CRIMP GALVANIZED STEEL

29-GAUGE ROOFING OVER 1x4

WOOD STRIPS @ 24"

5V CRIMP GALVANIZED STEEL

29-GAUGE ROOFING OVER 1x4

WOOD STRIPS @ 24" O.C. OVER

EXISTING SHINGLE ROOF

5V CRIMP GALVANIZED STEEL

29-GAUGE ROOFING OVER 1x4

WOOD STRIPS @ 24"

CONTINUES RIDGE VENT

OPEN OPEN

5V CRIMP GALVANIZED STEEL

29-GAUGE ROOFING OVER 1x4

WOOD STRIPS @ 24" O.C. OVER

EXISTING SHINGLE ROOF

CONTINUES RIDGE VENT

5V CRIMP GALVANIZED STEEL

29-GAUGE ROOFING OVER 1x4

WOOD STRIPS @ 24"

OPEN OPEN OPEN OPEN OPEN

CSC010125

1/4" = 1'-0"

01/24/25

JPD

JPD

SCOPE OF WORK:

DEMOLITION:

1. REMOVE METAL ROOFING ON FRONT PORCH.

2. REMOVE FOUR (4) ROOF VENTS.

NEW CONSTRUCTION:

1. INSTALL 5V CRIMP GALVANIZED STEEL 29-GAUGE ROOF

PANELS OVER 1x4 WOOD STRIPS AT 24" O.C. OVER

EXISTING SINGLES.

2. REPAIR DECKING WHERE EXISTING ROOF VENTS WERE

REMOVED WITH SAME THICKNESS OF DECKING AS

EXISTING AND INSTALL 2 LAYERS OF 15# FELT OVER NEW

DECKING.

3. INSTALL NEW GALVANIZED STEEL RIDGE VENT FOR FULL

LENGTH OF RIDGE.

4. INSTALL NEW 5V CRIMP GALVANIZED STEEL 29-GAUGE

ROOF PANELS ON PORCH ROOF, REPAIR/REPLACE 1x4

WOOD STRIPS AS REQUIRED.

SHEET NOTE:

1. CONTRACTOR TO VERIFY ALL ROOF SLOPES.

2. CONTRACTOR TO VERIFY ALL DIMENSIONS PRIOR TO

STARTING WORK.

3. ALL WORK SHALL BE PERFORMED IN A PROFESSIONAL

MANNER AND WORK AREA SHALL BE CLEANED AT THE

END OF INSTALLATION WITH CARE TO REMOVE ALL NAILS

FROM THE GROUND AROUND THE BUILDING.

4. CONTRACTOR SHALL DISPOSE OF ALL REMOVED

MATERIAL IN A SAFE AND LEGAL MANNER.

AutoCAD SHX Text

EXISTING ROOF PLAN

AutoCAD SHX Text 1/4" = 1'-0"

AutoCAD SHX Text

AutoCAD SHX Text FLORIDA REG. No. AR0013137

AutoCAD SHX Text

ST. CLOUD, FLORIDA 34769

AutoCAD SHX Text 1300 Ninth Street

AutoCAD SHX Text

BY

AutoCAD SHX Text

REVISIONS

AutoCAD SHX Text

OF

AutoCAD SHX Text

SHEETS

AutoCAD SHX Text

SHEET

AutoCAD SHX Text

JOB NO.

AutoCAD SHX Text

SCALE

AutoCAD SHX Text

DATE

AutoCAD SHX Text

CHECKED

AutoCAD SHX Text

DRAWN

AutoCAD SHX Text

PHONE: 407-957-7300

AutoCAD SHX Text

ST. CLOUD, FL. 34769

AutoCAD SHX Text

1375 SOUTH LAKE ROAD

AutoCAD SHX Text

CITY OF ST. CLOUD

AutoCAD SHX Text

REROOFING

AutoCAD SHX Text

REROOFING PLAN

AutoCAD SHX Text A1.0

AutoCAD SHX Text

REROOFING PLAN

AutoCAD SHX Text 1/4" = 1'-0"

AutoCAD SHX Text

AutoCAD SHX Text

FRONT ELEVATION

AutoCAD SHX Text 1/4" = 1'-0"

AutoCAD SHX Text

AutoCAD SHX Text

SIDE ELEVATION

AutoCAD SHX Text 1/4" = 1'-0"

AutoCAD SHX Text

Sheets and Views
A-1.0 FLOOR PLANS AND DETAILS

File details come from the government source that posted it. Updated .