1375_South_Lake_Road_.pdf
PDF 209 KB Posted
- Solicitation number
- 2025-059
- Issued by
- Polk County, Florida
About this file
This document is a roofing project technical specification and architectural drawing set for a roof repair and replacement project located at 1375 South Lake Road, associated with a hurricane damage repair solicitation in St. Cloud, Florida. The scope of work includes demolition of existing metal roofing on the front porch, removal of four roof vents, and new construction involving installation of 5V crimp galvanized steel 29-gauge roof panels over existing shingles, decking repairs, felt underlayment, and a new galvanized steel ridge vent for the full ridge length.
The technical drawing provides detailed specifications including roof slopes (8:12 and 2:12), precise dimensional measurements, and specific installation requirements. Key contractor instructions mandate verifying all roof slopes and dimensions prior to work, performing installation professionally, thoroughly cleaning the work area, and legally disposing of removed materials. The document includes front and side elevation views, existing and proposed roof plans, and is dated 01/24/25, suggesting this is part of a hurricane damage repair and restoration project for a municipal building in St. Cloud, Florida.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| Roof_Repairs_and_Replacement_Due_to_Hurricane_Damage.pdf | ||
| 3101_Progress_Lane_.pdf | ||
| Attachment_B_-_Federal_Requirements.pdf | ||
| Sample_Agreement.docx | DOCX document |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
'-0
30'-0"
'-4
26'-8"
SLOPE
8:12
S
LO
PE
:1
SLOPE
8:12
2'-0"2'-0"
'-6
26'-0"
EXISTING SHINGLE
ROOFING TO REMAIN
EXISTING ROOF VENTS TO BE
REMOVED AND HOLE ROOF
DECKING REPAIRED (TYP OF 4)
EXISTING 5V CRIMP
GALVANIZED STEEL
29-GAUGE ROOFING TO
BE REMOVED"
'-0
30'-0"
'-4
26'-8"
SLOPE
8:12
S
LO
PE
:1
SLOPE
8:12
2'-0"2'-0"
'-6
26'-0"
5V CRIMP GALVANIZED STEEL
29-GAUGE ROOFING OVER 1x4
WOOD STRIPS @ 24" O.C. OVER
EXISTING SHINGLE ROOF
CONTINUES RIDGE VENT
5V CRIMP GALVANIZED STEEL
29-GAUGE ROOFING OVER 1x4
WOOD STRIPS @ 24"
5V CRIMP GALVANIZED STEEL
29-GAUGE ROOFING OVER 1x4
WOOD STRIPS @ 24" O.C. OVER
EXISTING SHINGLE ROOF
5V CRIMP GALVANIZED STEEL
29-GAUGE ROOFING OVER 1x4
WOOD STRIPS @ 24"
CONTINUES RIDGE VENT
OPEN OPEN
5V CRIMP GALVANIZED STEEL
29-GAUGE ROOFING OVER 1x4
WOOD STRIPS @ 24" O.C. OVER
EXISTING SHINGLE ROOF
CONTINUES RIDGE VENT
5V CRIMP GALVANIZED STEEL
29-GAUGE ROOFING OVER 1x4
WOOD STRIPS @ 24"
OPEN OPEN OPEN OPEN OPEN
CSC010125
1/4" = 1'-0"
01/24/25
JPD
JPD
SCOPE OF WORK:
DEMOLITION:
1. REMOVE METAL ROOFING ON FRONT PORCH.
2. REMOVE FOUR (4) ROOF VENTS.
NEW CONSTRUCTION:
1. INSTALL 5V CRIMP GALVANIZED STEEL 29-GAUGE ROOF
PANELS OVER 1x4 WOOD STRIPS AT 24" O.C. OVER
EXISTING SINGLES.
2. REPAIR DECKING WHERE EXISTING ROOF VENTS WERE
REMOVED WITH SAME THICKNESS OF DECKING AS
EXISTING AND INSTALL 2 LAYERS OF 15# FELT OVER NEW
DECKING.
3. INSTALL NEW GALVANIZED STEEL RIDGE VENT FOR FULL
LENGTH OF RIDGE.
4. INSTALL NEW 5V CRIMP GALVANIZED STEEL 29-GAUGE
ROOF PANELS ON PORCH ROOF, REPAIR/REPLACE 1x4
WOOD STRIPS AS REQUIRED.
SHEET NOTE:
1. CONTRACTOR TO VERIFY ALL ROOF SLOPES.
2. CONTRACTOR TO VERIFY ALL DIMENSIONS PRIOR TO
STARTING WORK.
3. ALL WORK SHALL BE PERFORMED IN A PROFESSIONAL
MANNER AND WORK AREA SHALL BE CLEANED AT THE
END OF INSTALLATION WITH CARE TO REMOVE ALL NAILS
FROM THE GROUND AROUND THE BUILDING.
4. CONTRACTOR SHALL DISPOSE OF ALL REMOVED
MATERIAL IN A SAFE AND LEGAL MANNER.
AutoCAD SHX Text
EXISTING ROOF PLAN
AutoCAD SHX Text 1/4" = 1'-0"
AutoCAD SHX Text
AutoCAD SHX Text FLORIDA REG. No. AR0013137
AutoCAD SHX Text
ST. CLOUD, FLORIDA 34769
AutoCAD SHX Text 1300 Ninth Street
AutoCAD SHX Text
BY
AutoCAD SHX Text
REVISIONS
AutoCAD SHX Text
OF
AutoCAD SHX Text
SHEETS
AutoCAD SHX Text
SHEET
AutoCAD SHX Text
JOB NO.
AutoCAD SHX Text
SCALE
AutoCAD SHX Text
DATE
AutoCAD SHX Text
CHECKED
AutoCAD SHX Text
DRAWN
AutoCAD SHX Text
PHONE: 407-957-7300
AutoCAD SHX Text
ST. CLOUD, FL. 34769
AutoCAD SHX Text
1375 SOUTH LAKE ROAD
AutoCAD SHX Text
CITY OF ST. CLOUD
AutoCAD SHX Text
REROOFING
AutoCAD SHX Text
REROOFING PLAN
AutoCAD SHX Text A1.0
AutoCAD SHX Text
REROOFING PLAN
AutoCAD SHX Text 1/4" = 1'-0"
AutoCAD SHX Text
AutoCAD SHX Text
FRONT ELEVATION
AutoCAD SHX Text 1/4" = 1'-0"
AutoCAD SHX Text
AutoCAD SHX Text
SIDE ELEVATION
AutoCAD SHX Text 1/4" = 1'-0"
AutoCAD SHX Text
| Sheets and Views |
| A-1.0 FLOOR PLANS AND DETAILS |
File details come from the government source that posted it. Updated .