3 Soliciation Barometer Specifications Document Revision 3.pdf
PDF 15 KB Posted
- Attached to
- Barometric Pressure Sensors Federal contract opportunity
- Solicitation number
- 1305M224Q0101
About this file
This document is a Barometer Specifications Revised 4/26/2024 that details the technical requirements for a barometric pressure sensor being procured under Solicitation Number 1305M224Q0101 by the Department of Commerce National Oceanic and Atmospheric Administration.
The key details are: The solicitation is for barometric pressure sensors for the National Data Buoy Center at Stennis Space Center, MS. The Government has specified two manufacturer models, Druck Paroscientific TERPS RPS/DPS 8100 MET 1-2, with detailed performance specifications including range, resolution, accuracy, operating temperature, stability, power, and physical dimensions. The NAICS code is 334513 and the Government intends to procure the supplies using Simplified Acquisition Procedures under FAR Part 13. Contractors must be registered in the System for Award Management (SAM) to be eligible for award.
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| 3 Soliciation Barometer Specifications Document Revision 2.pdf | ||
| 3 Soliciation Barometer Specifications Document Revised.pdf | ||
| 3 Solicitation Amended.pdf | ||
| Solicitation .pdf | ||
| Sensor Brand and Model Justification.pdf | ||
| Barometer Specifications Document.pdf |
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Barometer Specifications Revised 4/26/2024
Manufacturer Druck Paroscientific
Model TERPS RPS/DPS 8100 MET 1-2
Output Format Digital - RS-232 Digital - RS-232
Range 750-1150 hPa 800-1100 hPa
Resolution 0.01 hPa 0.001 hPa
Accuracy (-40°C to +60°C) Improved Accuracy - 0.04 hPa
Improved Accuracy - 0.01 hPa
Improved Accuracy - 0.1 hPa
0.1 hPa
Operating Temperature Range -10°C to +50°C
-40°C to +85°C
-40°C to +50°C
Long Term Stability 0.04 hPa /year
0.01 hPa /year
0.1 hPa /year
0.1 hPa /year
Supply Voltage 7 to 28 VDC 6 to 16 VDC
Maximum Current Draw 32 mA 43 16 mA
Maximum Sensor Length (to fit in enclosure) 4.815 inches N/A - Enclosure provided
Maximum Sensor Diameter (to fit in enclosure) 0.98 inch N/A - Enclosure provided
Electrical Connector Polyurethane Cable N/A Cable internal to enclosure
Cable Length 3 feet N/A Cable internal to enclosure
Pressure Connector 1/4 NPT Female N/A Pressure Connector internal to enclosure
File details come from the government source that posted it. Updated .