This document contains technical evaluations for a solicitation seeking demountable architectural wall systems. The evaluations assess the offeror's compliance with specifications for floor-to-ceiling wall panels, panel faces of steel or glass, panel connections, doors including butt hinge and slide options, power and data distribution through separate feed points and wiring harnesses, and sound attenuation ratings. Additional requirements include accessibility standards, product warranties, availability guarantees, and environmental certifications. The related federal contract opportunity is solicitation number 6973GH-22-Q-00034 for demountable architectural walls at the Mike Monroney Aeronautical Center issued by the Department of Transportation Federal Aviation Administration Franchise Acquisition Services.
View the file
Other files
Show all 16
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Name of Offeror: Technical Evaluation 1
Technical Requirements Evaluation: WO#13-007860 MPB Renovation Demountable Architectural Walls N/A Not Acceptable Acceptable Comments
N/A
1. GENERAL REQUIREMENTS:
1.1. Accessibility. All components and design shall meet ADA and ABA (UFAS) guidelines.
1.2. ANSI/BIFMA - All furniture components shall comply with the applicable ANSI/BIFMA Standards.
1.3. Product Brochure. A manufacturer’s brochure(s) with color photographs of ALL the proposed furniture products shall be provided with bid package.
1.4. Product Specifications. A manufacturer’s detailed product specification to determine compliance with FAA specifications shall be provided with bid package.
1.5. Warranty. A manufacturer’s minimum 10-year product
warranty (excluding fabrics and lighting) shall be provided with bid package.
1.6. Availability. A manufacturer’s written guarantee of availability of components compatible with the original installation for a period of not less than five (5) years shall be provided with bid package.
1.7. Environmental Aspects. Provide manufacturer’s information with bid package:
Environmental Aspects are not evaluated on "quantity" of content, the intent is to approve manufacturer's that provide supporting documentation of sustainable & healthy manufacturing practices.
1.7.1. Recycled Content. Amount of recycled content.
1.7.2. Recyclable. Amount of post-consumer recyclable
materials.
1.7.3. Air Quality Certification. Emission standards for off-gassing of product components.
1.7.4. LEED Eligibility. Identification of LEED eligible products.
Name of Evaluator: Date:
Name of Offeror: Technical Evaluation 2
Renovation Demountable Architectural Walls N/A Not Acceptable Acceptable Comments
1.8. Product Colors. Furniture Contractor shall select products that provide the following minimum color choices. Provide samples with bid package.
1.8.1. Architectural Wall System:
1.8.1.1. Trim Colors – minimum five (5), pricing shall be
based on metallic finishes
1.8.1.2. Metal Skins- minimum of six (6) colors
1.8.1.3. Glazing – Clear, Frosted Glass or back painted
glass with a minimum two (2) patterns/colors.
2. ARCHITECTRUAL WALLS - PANELS, PANEL FACES, &
DOORS: N/A
2.1. Product Quality & Aesthetics: Architectural walls may be either Unitized (factory built-fully assembled panels for tilt-in installation) OR Demountable (components arrive and are assembled on site) and have a reveal design with vertical slotting for wall hung furniture components.
2.2. Panel Dimensions. Architectural wall panels shall be floor to ceiling design, capable of ceiling heights up to 9’ high and panel widths must be able to accommodate proposed design. Panels must be stackable to accommodate ceiling height changes and panel type changes. Frames (with panel faces attached) shall not exceed 4 inches thick,
2.3. Panel Face. Panel faces (skins) shall be constructed of 22 gauge steel skins, gypsum board panel faces will NOT be considered.
2.3.1. Metal Skins: A metal skins shall be factory finished
powder coated steel, available in choice of finish including marker board finish.
2.3.2. Captured Glass Frame: Glazed frame assemblies shall
be constructed of ¼” tempered glass and accommodate single glazed configurations
Name of Offeror: Technical Evaluation 3
Renovation Demountable Architectural Walls N/A Not Acceptable Acceptable Comments
2.4. Panel Connections & Framing Components: Architectural
wall systems shall be capable of connecting in a variety of configurations. Panel based systems shall allow for the connection of panels with different panel face finishes and the connection of two, three or four panels from a single point.
2.4.1. The connector system shall provide for the continuation of power and data wiring within panels.
2.4.2. End fillers (Wall Starters) for Architectural wall adjacent to fixed walls and columns shall be similar in construction to solid wall skins and fit into end channel on abutting wall.
2.4.3. Ceiling track shall be one piece continuous formed steel and shall be capable of being installed to the underside of suspended ceilings without using destructive fasteners.
2.4.4. Floor track shall be one piece continuous formed steel and shall be capable of being installed on hard floor surfaces and carpeted flooring without the use of mechanical fasteners.
2.5. Doors. Architectural wall system shall be capable of providing the following door types:
2.5.1. Butt Hinge Doors: Door frame shall be reversible
allowing the installer to change the door swing as part of the installation.
2.5.1.1. Frame: Door frame shall be formed steel and
aluminum and shall include continuous resilient sound seal at top and side jambs. Frame shall be capable of providing vertical adjustment to compensate for floor and ceiling irregularities without the need to cut the doors on site.
Name of Offeror: Technical Evaluation 4
Renovation Demountable Architectural Walls N/A Not Acceptable Acceptable Comments
2.5.1.2. KEYING: (Stanley/Best 1E Mortise Cylinder
with Best 7-pin construction core) in finish 626.
2.5.2. Slide Doors: Slide doors shall be fully supported by wall structure without requiring additional structural support from other architectural elements. Doors shall include fascia, header and track, finished opening frame and sliding door. Roller assemblies shall be constructed of steel with high quality ball bearing wheels and include pneumatic braking mechanism.
2.5.3. Door leaves: Doors shall be pre-finished and pre-
mortised for hardware .shall capable of providing either extruded aluminum or standard 5-ply wood door. Doors leafs shall be available in the following options:
2.5.3.1.1. Aluminum frame door shall be
constructed of pre-finished 1-3/4” extruded aluminum rails and stiles with 1/4” tempered glass view lite.
2.5.3.1.2. ,3/8” tempered glass (frameless) fully glazed,
2.6. Leveling and alignment. The system shall provide precise alignment of adjacent panels and shall provide a 3” vertical adjustment (+/- 1-1/2”) in overall height to compensate for uneven floors and ceiling irregularities.
2.7. Sound attenuation: Solid and framed glass systems must be in compliance with ASTM E 72 “standard test methods of conducting strength tests of panels for building construction”
2.7.1. Steel Clad Skins: Wall with steel clad skins must meet a minimum 42 STC without field added insulation or gaskets.
Name of Offeror: Technical Evaluation 5
Renovation Demountable Architectural Walls N/A Not Acceptable Acceptable Comments
2.7.2. Laminate & Veneer Skins: Solid walls with veneer of
laminate skins must meet a minimum of 37 STC without field added insulation or gaskets.
2.7.3. Glazed Walls: Single glazed walls must meet a minimum
of 30 STC with ¼” glass.
3. ARCHITECTURAL WALL - POWER AND DATA DISTRIBUTION:
N/A
3.1. Power and Data. Panels shall have a system capable of
distributing power service and data service to multiple workstations through separate feed points.
3.1.1. Base Feed: Power & Data must be capable of entering
the wall by the following methods:
3.1.1.1.1. Power & Data feeds may be through
ceiling junction boxes. Note: power & data may not be run adjacent through the same panel unless it is either separated by a minimum of 24” or in flexible metal conduit and properly shielded.
3.1.2. Power System. Power/Data panels shall include an
electrical system that is UL rated and meets all current National Electrical Code (NFPA 70) requirements. A minimum 8-wire, 3-circuit system (with minimum 20-amp 125 volts per circuit capacity) and minimum #12 AWG wire size shall be used. NOTE: 10 wire, 4 circuit system may be substituted, provided separate neutrals are provided for each circuit.
3.1.2.1. The power wiring system must provide a
separate and unique neutral conductor per circuit (i.e.: 3 circuits, 3 neutrals, and 2 grounds minimum).
Name of Offeror: Technical Evaluation 6
Renovation Demountable Architectural Walls N/A Not Acceptable Acceptable Comments
3.1.2.2. Duplex receptacles shall be provided as shown
on the typical. Power outlets shall be 20 amps duplex (NEMA 5-20R). Each duplex outlet shall have a label that identifies the phase of the circuit to which it is connected.
Power wiring system should have the capability of having the outlets installed back-to-back.
3.1.2.3. The power wiring harness system shall be
located in or near the base of the panels.
3.1.3. Data Cable Management. Power/Data panels shall have
a data channel that is properly separated OR shielded from electrical sources. Panels shall offer the following capacities for routing data cables.
3.1.3.1. Furniture vendors shall provide flush mounted
faceplates, bezel and blank covers capable of accepting standard Aeronautical Center data receptacles.
3.1.3.1.1. Knockout plates in the panel face shall
be capable of providing a minimum of 3 potential jacks per workstation. Data faceplates must be capable of three (3) RJ45 Systimax, Part # MGS400BH-112 (ORANGE) at each location shown