This document is a Request for Proposals (RFP) issued by the United States Department of Agriculture (USDA) Farm Production and Conservation - Acquisition and Procurement Division on behalf of the USDA Natural Resource Conservation Service. The RFP is for the construction of an Equipment Storage Building, Pesticide Storage Shed, Bulk Fuel Tank Station, and Gravel Driveway at the Golden Meadow Plant Materials Center in Galliano, Louisiana.
The objectives of the project are to provide shop drawings, materials, labor, and equipment to construct a 50' x 100' pre-engineered steel equipment storage building with an attached overhang and lean-to canopy, a 9' x 15' pesticide storage shed with a concrete apron, a bulk fuel storage tank area, and a gravel parking lot. The RFP is a 100% Small Business set-aside, with a NAICS code of 236210 (Industrial Building Construction) and a $39.5M size standard. Award will be made as a firm fixed-price construction contract under FAR Part 15 procedures. Bid, performance, and payment bonds are required. The period of performance is 240 calendar days from the Notice to Proceed. The estimated project magnitude is between $500,000 and $1,000,000.
View the file
Other files
Show all 19
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Pre-Engineered Building
50' wide
100' long
Front Elevation / East Facing
14' tall 16' tall
14' wide 14' wide 20' wide
Back Elevation / West Facing
16' tall 14' tall
20' wide 14' wide
Left Side Elevation / South Facing
25' lean-to-canopy
5' overhang
20' tall
Right Side Elevation / North Facing 25' lean-to-canopy
5' overhang
20' tall
Sheeted on lean-to-canopy side
Interior Tool & Storage Room
28' Tool Room
20'
50' wide
Storage Room 8'
4'
100' long
Front view of interior room with above loft Removeable Handrail
4' high handrail
10' height
36' wide side view of above storage loft with stairs
Electrical & Lighting
Existing 200A Single Phase Service Location install new double throw disconnct switch new 200A Single Phase (Electric Panel Location)
Interior Light 110V Oulet 220V Outlet Single Light Switch 4-Way Light Switch Exterior Light
200A Single Phase (Electric Panel Location)
Note:
Pesticide Storage Building and Bulk Fuel Tank station needs to be wired into Single Phase Electrical Panel