Questions and Responses 5.14.24.pdf
PDF 183 KB Posted
- Solicitation number
- 12FPC224Q0021
About this file
This document is a set of Questions and Answers related to RFQ #12FPC224Q0021 for USDA FPAC Audio Video Conference Room Equipment, Installation, Testing, and Training. The USDA is seeking to install a modular video conferencing system, including two 86-inch 4K displays with flat wall mounts, an auto-tracking camera, and wireless connectivity. Key details include:
The system must be TIAA-compliant, but there is no preferred brand. It does not require touch screen capability. The USDA will issue a Purchase Order rather than using a contract vehicle. The initial delivery/installation date of June 4, 2024 has flexibility. The conference room has 8-ft ceilings with 2'x2' ceiling tiles, and the AV rack will be centered below the displays. The USDA will provide guidance on monitor placement and some GFE. The vendor will provide onsite support during the initial board meeting, with training required prior to that meeting. No maintenance visits are required during the warranty period, and the vendor will not have remote access to the system.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
QUESTIONS AND ANSWERS
USDA FPAC CONFERENCE ROOM EQUIPMENT, INSTALLATION,
TESTING, AND TRAINING
12FPC224Q0021
Question 1 - We see you have requested (2) new 86in wall mounted displays but, the BOM explains we want a “modular” video conferencing system. Can you elaborate on what we mean by modular? I would read that as we'd like the system integrated into a mobile cart however then the displays should be mounted to the cart, not wall mounted as previously stated.
Response – Monitors will be wall mounted.
Question 2 - TV brand preference and TIAA compliance (Samsung, Panasonic...etc.)?
Response – The TV must be TIAA compliant. Otherwise, there is no preference.
Question 3 - What type of wall mounts i.e. tilt or flat?
Response – Flat
Question 4 - Touch screen capabilities?
Response – Not required.
Question 5 - Tracking camera: speaker tracking, presenter tracking or voice tracking?
Response – Yes
Question 6 - Existing power at camera locations?
Response – Yes
Question 7 - Is there an existing core in the floor at the table location or it will be provided to us for cable runs?
Response – No. If required, cable runs will be surface mounted with protection.
Question 8 - What contract vehicle will be used to award this?
Response – USDA will not be using a contract vehicle. A Purchase Order will be issued.
Question 9 – Is there is any flexibility on the June 4th delivery / installation date as stated in section VII of RFQ#
12FCP224Q0021.
Response – Yes, there is flexibility on the delivery date.
Question 10 – What is the Ceiling Height?
Response – 8 Ft
Question 11 – What type of ceiling?
Response – 2’ X 2’ Tiles
Question 12 – Is there a designated location for the AV Rack? Or would you like all of the system to be behind the TV?
Response – AV rack will be centered below the monitors.
Question 13 – Will the Government please provide the Site Visit Attendee List?
Response – The Site Visit Attendee List will be posted with the RFQ on www.sam.gov.
Question 14 - When do you anticipate that the solicitation will be awarded since the POP is by June 4th?
Response – The POP has been changed to be determined.
Question 15 - Do you want the training to take place prior to the meeting on June 7th, since you have requested support for the day of the meeting?
Response – Yes, the training needs to take place prior to the meeting on June 7th.
Question 16 - Will the government provide guidance on monitor placement based on the recommendations of the contractor?
Response – Yes
Question 17 - How long will the meeting be on June 7th, the day when onsite support is needed?
Response – The meeting will be from 8:00 am to 4:00 pm ET.
Question 18 - Does the government require HDMI connections at the conference room table for BYOD? If so, how many?
Response – No, we do not require HDMI connections at the conference room table.
Question 19 - The SOW mention that the system should allow for Wi-Fi connections, please elaborated on what the intent is for this function.
Response – A way for the participants in the room to wirelessly connect and share, as opposed to having to use cables. Support of a dongle device is allowed.
Question 20 - Are there periodic maintenance visits required? If so, at what intervals?
Response – No, there is no need for maintenance visits.
Question 21 - Will there be any GFE used?
Response – Yes, GFE will be available.
http://www.sam.gov/
Question 22 - Is there a requirement to provide power and data connections for the conference table?
Response – No
Question 23 - Will the government be responsible for ensuring the power and data connections are placed behind the monitors that are being installed?
Response – Yes
Question 24 - The power outlets on the wall where the LCDs will go, are these outlets from the same circuit? Is the entire room in one circuit?
Note: the reason for this question is to ensure all the new equipment will have enough amperage available to operate efficiently.
Response – No. Different circuits.
Question 25 - Noticed there are only two outlets available on the wall, can there be at least two per monitor?
Response – The are two (2) duplexes and two (2) Data on the wall. One (1) duplex and one (1) data will be moved to 70” AFF.
Question 26 - Are there any restrictions/requirements for adding new computers/devices into the USDA’s Network? If so, can the requirements be made available.
Response –These restrictions/requirements are limited to working with the Department in the installation of the device(s). Any computers/laptops needed for this project will be GFE
Question 27 - Are we to assume that a Service Level Agreement to support this system is needed during the equipment’s warranty period? or will the system be inherited by the existing IT department?
Response –Yes
Question 28 - Will the Installer/Vendor have remote access to the computer/devices after installation to provide remote support during the warranty period?
Response –No
Question 29 - By warranty period, are you referring to the installer/vendor’s warranty period (typically 1 year) or the manufacturer’s warranty (varies)
Response – Installer/Vendor warranty