CONSTRUCTION STAGING

AREA, CONTACT OWNER FOR

APPROXIMATE LOCATION

ASSISTANT STATION DIRECTOR OF OPERATIONS DATE

SHEET OF

United States Department of Agriculture Forest Service

TRAVEL DIRECTIONS:

STATION ENGINEER DATE

PROGRAM MANAGER DATE

APPROVED:

RECOMMENDED BY:

PROJECT LOCATION

PROJECT SITE

5/

/2

4:

:1

P

M

ISSUE DATE:

A&E PROJECT NUMBER:

5/23/19

FIRE LAB

AIR QUALITY &

ELECTRONIC LAB

5775 US HIGHWAY 10W

MISSOULA, MT 58908

18075.00

PROJECT SITE: MISSOULA, MT

FROM THE CITY OF MISSOULA, TRAVEL NORTHWEST ON I-90 TOWARD FRENCHTOWN. TAKE EXIT 99 FROM I-90 W TO AIRWAY BLVD. TURN RIGHT ONTO W BROADWAY ST / US HIGHWAY 10W FOR APPROX 1.0 MILE. TURN LEFT TOWARD

THE SMOKEJUMPER VISITOR CENTER AND THE DESTINATION (FIRE LAB) IS ON YOUR LEFT.

OWNER

ARCHITECT

MECHANICAL ENGINEER

ELECTRICAL ENGINEER

CHRIS MARTISON, PRINCIPAL-IN-CHARGE

SCOTT MOSES, PROJECT ARCHITECT

LUCAS YATCH, DESIGNER

A&E

222 NORTH HIGGINS

MISSOULA, MONTANA 59802

406.721.5643

US FOREST SERVICE

ROCKY MOUNTAIN RESEARCH STATION

5775 US HIGHWAY 10W

MISSOULA, MONTANA 59808

ERIC J. WEBBER, PE, LEED AP BD+C

MORRISON-MAIERLE, INC. 3011

1055 MOUNT AVE

MISSOULA, MONTANA 59801

406.542.4834

ARIAN C. BLOOMFIELD, PE, LEED AP BD+C, GGP

MORRISON-MAIERLE, INC.

1055 MOUNT AVE

MISSOULA, MONTANA 59801

406.542.4819

AB ANCHOR BOLT

ABV ABOVE

A/C AIR CONDITIONING

ACT ACOUSTICAL CEILING TILE

ADDL ADDITIONAL

ADJ ADJUSTABLE

AFF ABOVE FINISH FLOOR

ALT ALTERNATE

ALUM ALUMINUM

ARCH ARCHITECT(URAL)

AWN AWNING

B/ BOTTOM OF

BD BOARD

BLDG BUILDING

BLKG BLOCKING

BM BEAM OR BENCHMARK

BRG BEARING

BTWN BETWEEN

BUR BUILT-UP ROOF

CAB CABINET

CJ CONTROL JOINT

CL CENTERLINE

CLG CEILING

CMU CONCRETE MASONRY UNIT

CO CLEAN OUT

COL COLUMN

CONC CONCRETE

CONT CONTINUOUS

CONST CONSTRUCTION

CG CORNER GUARD

CPT CARPET

CSMT CASEMENT

CT CERAMIC TILE

D DEEP

DF DRINKING FOUNTAIN

DH DOUBLE HUNG

DIM(S) DIMENSIONS

DISP DISPENSER

DN DOWN

DR DOOR

DS DOWNSPOUT

DTL DETAIL

DWG DRAWING

E EAST

EA EACH

EC EXISTING COLUMN

EJ EXPANSION JOINT

ELEC ELECTRICAL

EL ELEVATION

ELEV ELEVATOR

EQ EQUAL

EQUIP EQUIPMENT

EWC ELECTRIC WATER COOLER

EXH EXHAUST

EXIST EXISTING

EXP EXPANSION OR EXPOSED

EXT EXTERIOR

FACP FIRE ALARM CONTROL PANEL

FD FLOOR DRAIN

FE FIRE EXTINGUISHER

FEC FIRE EXTINGUISHER CABINET

F.F. FINISH FLOOR

FIN FINISH

FIXT FIXTURE

FLR FLOOR

FND FOUNDATION

FP FIRE PROTECTION

FR FRAME

FRMG FRAMING

FT FEET/FOOT OR FIRE TREATED

FTG FOOTING

FTNG FOOTING

FRP FIBERGLASS REINFORCED

PANEL

FRT FIRE RETARDANT TREATED

GA GAUGE

GALV GALVANIZED

GB GYPSUM BOARD

GC GENERAL CONTRACTOR

GL GLASS, GLAZING

GWB GYPSUM WALL BOARD

GYP GYPSUM

HC HANDICAP

HDR HEADER

HDW HARDWARE

HM HOLLOW METAL

HORIZ HORIZONTAL

HR HOUR

HT HEIGHT

HTD HEATED

HVAC HEATING/VENTILATION & AIR

CONDITIONING

HT HEIGHT

HTD HEATED

HVAC HEATING/VENTILATION & AIR

CONDITIONING

ID INSIDE DIAMETER

INFO INFORMATION

ISO ISOCYANURATE

INSUL INSULATE / INSULATED / INSULATION

INT INTERIOR

INV INVERT

JT JOINT

J-BOX JUNCTION BOX

KIT KITCHEN

L LONG / LENGTH

LAM LAMINATE(D)

LAV LAVATORY

LF LINEAR FEET

LT LIGHT

MAS MASONRY

MATL MATERIAL

MAX MAXIMUM

MECH MECHANIC(AL)

MEZZ MEZZANINE

MFR MANUFACTURER

MH MANHOLE

MIN MINIMUM

MISC MISCELLANEOUS

MO MASONRY OPENING

MTL METAL

N NORTH

NIC NOT IN CONTRACT

NOM NOMINAL

NTS NOT TO SCALE

OC ON CENTER

OD OUTSIDE DIAMETER OR OVERFLOW

DRAIN

OPNG OPENING

OPP OPPOSITE

OSB ORIENTED STRAND BOARD

OVHD OVERHEAD

PL PLATE

PLAM PLASTIC LAMINATE

PLUMB PLUMBING

PLYWD PLYWOOD

PNL PANEL

PNT PAINT

POLY POLYESTER OR POLYOLEFIN

PSF POUNDS PER SQUARE FOOT

PSI POUNDS PER SQUARE INCH

PT PRESSURE TREATED OR POINT

PVMT PAVEMENT

QT QUARRY TILE

QTR QUARTER

QTY QUANTITY

R RADIUS

RA RETURN AIR

RB RUBBER BASE

RD ROOF DRAIN

RECY RECYCLE(D)

REF REFERENCE

REFRIG REFRIGERATOR OR

REFRIGERATION

REINF REINFORCE

REQD REQUIRED

RM ROOM

RO ROUGH OPENING

ROW RIGHT OF WAY

S SOUTH

SC SOLID CORE

SCH SCHEDULE

SCHED SCHEDULED

SECT SECTION

SF SQUARE FEET

SFRM SPRAY APPLIED FIRE RESISTIVE

MATERIAL

SGL SINGLE

SHT SHEET

SHTG SHEATHING

SIM SIMILAR

SPECS SPECIFICATIONS

SOD SLAB ON DECK

SOG SLAB ON GRADE

SOH SAME OPPOSITE HAND

SS STAINLESS STEEL

ST STONE TILE

STD STANDARD

STND STANDARD

STL STEEL

STRUCT STRUCTURAL

TEMP TEMPERED

THK THICK

THRESH THRESHOLD

T.O. TOP OF

TOBM TOP OF BEAM

T.O.BM. TOP OF BEAM

T.O.P. TOP OF PLATE

T.O.S. TOP OF STEEL

T/ TOP OF

T&G TONGUE AND GROOVE

TEL TELEPHONE

THK THICK

TRANS TRANSOM

TV TELEVISION

TYP TYPICAL

UL UNDERWRITERS LABORATORY

UNO UNLESS NOTED OTHERWISE

VB VINYL BASE

VCT VINYL COMPOSITION TILE

VERT VERTICAL

VEST VESTIBULE

VIF VERIFY IN FIELD

VP VENEER PLASTER

VR VAPOR RETARDER

VT VINYL TILE

VWC VINYL WALL COVERING

W WIDE OR WEST

W/ WITH

WC WATER CLOSET

WD WOOD

WDW WINDOW

WG WALL GUARD

WH WATER HEATER

W/IN WITHIN

W/O WITHOUT

WP WATERPROOF

WR WATER RESISTANT

WT WEIGHT

WWF WELDED WIRE FABRIC

# NUMBER OR POUND

@ AT

WINDOW TAGROOM TAG

DOOR TAG KEYNOTE TAG

ASSEMBLY TAG

MATERIAL TAG

REVISION TAGREVISION CLOUD R

REF

ELE

V

G6S

M

K

W

CEILING TAG VIEW REFERENCEREF. #/A#.#

BUILDING

SECTION

WALL

SECTION

ELEVATION

GRID LINE

DETAIL

CALL OUT

INTERIOR

ELEVATION

EXTERIOR

ELEVATION

DETAIL

SECTION

#1

#2

#3

#4

A1.#15

POSITION OF VIEW ON

SHEET

SHEET OF ORIGIN

TYPICAL SHEET VIEW NUMBERING LAYOUTS

DETAIL NAME

1 1/2" = 1'-0"

VIEW

SCALE

VIEW NAME

ARCH D (24"x36")

A6.#

A3.#

A3.#

A3.#

A4.#

A3.#

ROOM NAME

101.1

PROJECT NO.

CHECKED

DRAWN

DESIGNER

DATE ARCHIVE NO.

DRAWING SHEET NO.

SHEET OF

REVISION

PROJECT NAME

DATEREVISION / ISSUENO.

REVISION DATE

REVISION DATE

REVISION DATE

United States Department of Agriculture Forest Service

DRAWING TITLE

FIRE LAB AIR

QUALITY &

ELECTRONIC LAB

5/

/2

4:

:1

P

M

G0.1

05.23.19

C O

N S

T R

U C

T

IO

N D

O C

U M

E N

T S

GENERAL

INFORMATION

18075.00

SM

LY

SM/LY

SHEET INDEXARCHITECTURAL ABBREVIATIONS

PROJECT TEAM

EXPLANATION OF SYMBOLS

ARCHITECTURAL

ELECTRICAL

MECHANICAL

PLUMBING

SHEET NO. SHEET NAME

G0.0 COVER SHEET

G0.1 GENERAL INFORMATION

D2.1 OVERALL DEMOLITION PLANS

D3.1 DEMOLITION ENLARGED PLAN AREA B

D3.2 DEMOLITION ENLARGED PLAN / SECTION AREA C

D7.1 DEMOLITION RCP

A2.1 OVERALL CONSTRUCTION FLOOR PLANS

A3.1 ENLARGED PLANS AREA B

A3.1F FLOOR FINISH PLANS AREA B

A3.2 ENLARGED PLANS AREA C

A3.2F FLOOR FINISH PLANS AREA C

A4.1 EXTERIOR ELEVATIONS / AREA C ROOF PLAN

A5.1 SECTIONS AREA C

A6.1 INTERIOR ELEVATIONS

A6.2 INTERIOR ELEVATIONS

A6.3 INTERIOR ELEVATIONS

A7.1 REFLECTED CEILING PLANS

A9.1 SCHEDULES

SHEET NO. SHEET NAME

DE2.1 LEVEL 1 ELECTRICAL DEMOLITION PLAN

E0.1 SYMBOLS AND ABBREVIATIONS

E2.1 ELECTRICAL WORK KEY PLANS

E2.2 LEVEL 1 ENLARGED POWER PLAN

E2.3 LEVEL 1 ENLARGED POWER PLAN

E2.4 LEVEL 2 & BASEMENT POWER PLANS

E2.5 LEVEL 1 SIGNAL PLAN

E2.6 AREA C SIGNAL PLAN

E7.1 LEVEL 1 LIGHTING PLAN

E9.0 ONE-LINE DIAGRAM

E9.1 ONE-LINE DIAGRAM

E9.2 DETAILS

E9.3 PANEL SCHEDULES

E9.4 PANEL SCHEDULES

E9.5 PANEL SCHEDULES

E9.6 PANEL SCHEDULES

E9.7 PANEL SCHEDULES

E9.8 PANEL SCHEDULES

E9.9 PANEL SCHEDULES

E9.10 PANEL SCHEDULES

E9.11 PANEL SCHEDULES

E9.12 PANEL SCHEDULES

E9.13 PANEL SCHEDULES

E9.14 PANEL SCHEDULE/DETAILS

SHEET NO. SHEET NAME

DM2.0 OVERALL HVAC DEMOLITION PLAN - BASEMENT

DM2.1 OVERALL HVAC DEMOLITION PLAN - LEVELS 1 AND 2

DM3.1 ENLARGED HVAC DEMOLITION PLANS - AREA B

DM3.2 ENLARGED HVAC DEMOLITION PLANS - AREA B

DM3.3 ENLARGED HVAC DEMOLITION PLANS - AREA C

M0.1 MECHANICAL COVER SHEET

M2.0 OVERALL HVAC PLAN - BASEMENT

M2.1 OVERALL HVAC PLAN - LEVELS 1 AND 2

M3.1 ENLARGED HVAC PLANS - AREA B

M3.2 ENLARGED HVAC PLANS - AREA B

M3.3 ENLARGED HVAC PLANS - AREA C

M3.4 ENLARGED HVAC PLANS - LEVEL 2

M9.1 MECHANICAL SCHEDULES

M9.2 MEP COORDINATION

M9.3 MECHANICAL DETAILS

M9.4 MECHANICAL CONTROL DETAILS

M9.5 MECHANICAL CONTROL DETAILS

M9.6 MECHANICAL CONTROL DETAILS

SHEET NO. SHEET NAME

DP2.1 OVERALL PLUMBING DEMOLITION PLAN - LEVEL 1

DP3.1 ENLARGED PLUMBING DEMOLITION PLANS - AREAS B AND C

P2.0 OVERALL PLUMBING PLAN - BASEMENT

P2.1 OVERALL PLUMBING PLAN - LEVEL 1

P3.1 ENLARGED PLUMBING PLANS - AREA B

P3.2 ENLARGED PLUMBING PLANS - AREA C

P9.1 PLUMBING SCHEDULES AND DETAILS

ALTERNATES

1. B-WING & C-WING CARPET FLOORING REPLACEMENT

2. 1ST FLOOR B-WING WINDOW REPLACEMENT / NEW ROLLER WINDOW SHADES

3. 2ND FLOOR B-WING WINDOW REPLACEMENT / NEW ROLLER WINDOW SHADES

4. HANDRAIL UPGRADE FOR STAIRWELLS IN B-WING TO MEET ADA/ABA

5. FIBER OPTIC CABLE CONNECTIVITY REPLACEMENT

6. LABORATORY EQUIPMENT - TANK RACKS

1. ASBESTOS ABATEMENT WILL BE REQUIRED BY THE GENERAL CONTRACTOR, REFER TO

REPORTS IN THE PROJECT MANUAL FOR ADDITIONAL INFO.

2. IT IS THE CONTRACTOR'S RESPONSIBILITY TO FAMILIARIZE HIMSELF/ HERSELF WITH THE SCOPE

OF WORK.

3. THE DEMOLITION NOTES PROVIDE A GENERAL DESCRIPTION OF THE ITEMS AND AREAS

REQUIRING REMOVAL. THE CONTRACTOR SHALL FIELD VERIFY ACTUAL QUANTITIES AND

LOCATIONS OF ALL INDICATED ITEMS AS NECESSARY TO COMPLETE THE SCOPE OF WORK IN

ACCORDANCE WITH THE CONTRACT DOCUMENTS.

4. COORDINATE WITH OWNER FOR ANY EQUIPMENT TO BE SALVAGED. UNLESS SPECIFICALLY

SCHEDULED FOR REUSE, DEMOLISHED MATERIALS SHALL BECOME THE POSSESSION OF THE

CONTRACTOR AND SHALL BE IMMEDIATELY REMOVED FROM THE SITE.

5. REMOVE MATERIALS FROM SITE AND DISPOSE OF IN A LEGAL MANNER AT NO ADDITIONAL

EXPENSE TO OWNER

6. DEBRIS FROM THE DEMOLITION SHALL NOT BE ALLOWED TO ACCUMULATE WITHIN THE BUILDING

OR ON THE SITE.

7. REMOVE FROM SITE ANY CONTAMINATED, VERMIN INFESTED, OR DANGEROUS MATERIALS

ENCOUNTERED AND DISPOSE OF BY SAFE MEANS SO AS NOT TO ENDANGER HEALTH OF

WORKERS AND PUBLIC.

8. BURNING OF MATERIALS ON SITE IS NOT PERMITTED.

9. CLEAN-UP: MUST MEET GOVERNING DUST CONTROL CODES.

10. NOTIFY AFFECTED UTILITY COMPANIES BEFORE STARTING WORK AND COMPLY WITH THEIR

REQUIREMENTS. INCLUDING FS CIO.

11. PREVENT MOVEMENT OR SETTLEMENT OF ADJACENT STRUCTURES. PROVIDE BRACING AND

SHORING.

12. CARRY OUT DEMOLITION WORK TO CAUSE AS LITTLE INCONVENIENCE TO ANY ADJACENT

OCCUPIED BUILDING OR SITE AS POSSIBLE AND WITH MINIMUM INTERFERENCE TO PUBLIC OR

PRIVATE ACCESSES. MAINTAIN PROTECTED EGRESS AND ACCESS AT ALL TIMES.

13. CONTRACTOR SHALL PROVIDE TEMPORARY DUST AND CONSTRUCTION SEPARATION WALLS AS

REQUIRED TO SHIELD THE PUBLIC FROM NOISE, DUST, WEATHER, AND OTHER HAZARDS THAT

MAY BE EXPOSED AS A RESULT OF THE DEMOLITION WORK.

14. PERFORM CUTTING OF EXISTING CONCRETE AND MASONRY WITH SAWS AND CORE DRILLS. DO

NOT USE JACK-HAMMERS EXCEPT WHERE PERMITTED BY OWNER.

15. BREAK CONCRETE AND MASONRY INTO SECTIONS LESS THAN 3 FEET IN ANY DIMENSION.

16. CONTRACTOR SHALL TAKE ALL NECESSARY PRECAUTIONS TO INSURE EXISTING STRUCTURAL

ELEMENTS REMAIN UNDAMAGED THROUGHOUT CONSTRUCTION, UNLESS SPECIFICALLY NOTED

ON DEMOLITION PLAN. IT IS THE SOLE RESPONSIBILITY OF THE CONTRACTOR TO IDENTIFY AND

PROVIDE ANY SHORING, BRACING, OR TEMPORARY STRUCTURE, AND TO COORDINATE WITH

STRUCTURAL ENGINEER AS REQUIRED.

17. IT IS THE OWNER'S INTENT TO OPERATE ON SITE THROUGHOUT CONSTRUCTION. CONTRACTOR

TO COORDINATE WITH OWNER ON PHASING, AND SCHEDULING OF WORK AS NOT TO CONFLICT

WITH THE AIRPORT OPERATIONS.

18. ALL PUBLIC UTILITIES TO REMAIN IN OPERATION THROUGHOUT CONSTRUCTION. CONTRACTOR

TO COORDINATE ANY TEMPORARY SERVICES REQUIRED TO MAINTAIN BUSINESS OPERATIONS.

19. SEE ENGINEERING DRAWINGS FOR DUCTWORK, DIFFUSER, PLENUM BOX, ETC. DEMOLITION

AND/OR PROTECTION. COORDINATE WITH MECHANICAL ENGINEER.

20. FIRE SAFETY MUST BE MAINTAINED FOR ALL PERSONNEL WORKING ON THE FLOOR. ALL FIRE

STAIRS, ALARMS, SPEAKERS, ETC. MUST REMAIN ACCESSIBLE AND OPERABLE AT ALL TIMES.

CONTRACTOR SHALL MAKE NECESSARY PROVISIONS TO PROTECT THIS EQUIPMENT.

IMMEDIATELY NOTIFY BUILDING SECURITY AND BUILDING MANAGER OF DAMAGED OR DISABLED

SYSTEMS AND REPAIR OR REPLACE DAMAGED SYSTEMS IMMEDIATELY. RELOCATION OF SMOKE

DETECTORS, PUBLIC ADDRESS SPEAKERS AND FIRE ALARM EQUIPMENT, NECESSITATED BY

NEW CONSTRUCTION, SHALL BE ACCOMPLISHED AS A FIRST PRIORITY, AND PER THE PLANS.

21. IF ANY QUESTIONS ARISE AS TO THE REMOVAL OF ANY MATERIAL, CLARIFY THE POINT IN

QUESTION WITH THE OWNER BEFORE PROCEEDING. IMMEDIATELY STOP WORK IF HAZARDOUS

MATERIALS ARE FOUND AND CONTACT THE OWNER'S REPRESENTATIVE.

22. REMOVAL OF ANY EQUIPMENT, CABLING SWITCHES, AND CONDUIT PERTAINING TO

DATA/COMMUNICATIONS AND TELEPHONE SHALL BE VERIFIED WITH TELEPHONE COMPANIES,

SERVICE OWNER OR TENANT DATA/COMMUNICATIONS REPRESENTATIVE AS REQUIRED TO

PREVENT NEW CONSTRUCTION DELAYS.

23. PROVIDE FOR FIRE PROOFING REPAIR AS REQUIRED AT STRUCTURAL STEEL, TO THE ORIGINAL

RATING WHERE CONSTRUCTION TRADES REMOVE EXISTING FIRE PROOFING. REPAIR ANY

DAMAGE OR PENETRATIONS IN RATED ASSEMBLIES TO CONFORM TO THEIR ORIGINAL LISTING

REQUIREMENTS AND TO MAINTAIN FIRE PROTECTION AND SEPARATION AS ORIGINALLY

DESIGNED.

24. AT COMPLETION OF DEMOLITION WORK, THE CONSTRUCTION AREA(S) SHALL BE LEFT IN "BROOM

CLEAN" CONDITION. ALL DEBRIS AND MISCELLANEOUS MATERIAL SHALL BE REMOVED.

25. CONTRACTOR SHALL BE RESPONSIBLE FOR PATCHING AND/OR REPAIRING ANY DAMAGE

CAUSED BY HIM OR HIS SUBCONTRACTORS. REFINISH TO MATCH EXISTING ADJACENT FINISH,

OR AS NOTED HEREIN.

26. FOR AREAS NOT IN DEMOLITION SCOPE OF WORK, PROTECT AS REQUIRED, ALL SURFACES, EQUIPMENT, FIXTURES AND HARDWARE DURING DEMOLITION AND/OR CONSTRUCTION.

27. PRIOR TO DEMOLITION, INVESTIGATE WALLS FOR CONCEALED PIPING AND INFORM

OWNER/ARCHITECT OF ANY CONDITION NOT DOCUMENTED IN CONTRACT DRAWINGS. DEMO

DESIGNATED WALL BASES, WALL FRAMING, BATT INSULATION AND GYPSUM BOARD. DEMO

CONDUITS AND RECEPTACLES, REFERENCE ELECTRICAL DEMO PLAN FOR ADDITIONAL

INFORMATION.

28. ALL EXISTING DIRECTIONAL SIGNAGE TO BE REMOVED UNLESS NOTED OTHERWISE.

29. WHERE NOTED, REMOVE FLOORING DOWN TO TOP OF CONC. SLAB, INCLUDING ADHESIVES,

TRANSITION STRIPS, AND OTHER ASSOCIATED ELEMENTS, TYP., UNLESS NOTED OTHERWISE.

PREPARE REMAINING SURFACES TO RECEIVE NEW FINISHES.

INDICATES BUILT ITEM TO BE REMOVED

DEMO (E) FLOOR FINISH

DEMO (E) CARPET ALT-1

A

C

E

F

123456

G

H

J

78910111220

(E) LOBBY &

DISPLAY

101 B

(E) OFFICE

118 B

(E) OFFICE

119 B

(E) OFFICE

120 B

(E) OFFICE

121 B

(E) OFFICE

122 B

(E) OFFICE

123 B

(E) OFFICE

124 B

(E) OFFICE

125 B

(E) MEN'S RR

126 B

(E) WOMENS

RR

127 B

(E) OFFICE

129 B

(E) OFFICE

104 B

(E) RECIVING

& SHIPPING

106 B

(E) JAN

107 B

D3.1

D3.1

D3.2

(E) OFFICE

128 B

(E) OFFICE

105 B

01-02

01-04

01-04

(E) OFFICE

108B

(E) DARK

ROOM

109B

(E) OFFICE

110B

(E) OFFICE

111B (E)

INSTRUMENT

CALIBRATION

113 B

(E) OFFICE

113-1 B

(E)

INSTRUMENT

DEV. LAB

115 B

(E) TOILET

102 B

(E) STORAGE

101 C

(E) HALL

104 C

(E) OFFICE

108 C

(E) OFFICE

106 C

(E) OFFICE

106 C

UP

UP

A

C

E

F

123456789101112

DN

D N

(E) OFFICE

212 B

(E) OFFICE

213 B

(E) OFFICE

211 B

(E) OFFICE

215 B

(E) OFFICE

216 B

(E) OFFICE

217 B

(E) OFFICE

218 B

(E) OFFICE

219 B

(E) OFFICE

220 B

(E) MENS

221 B

(E) WOMEN

222 B

(E) OFFICE

223 B

(E) OFFICE

224 B

(E) OFFICE

201 B

(E) OFFFICE

203 B

(E) STOCK

ROOM

204 B

(E) OFFICE

206-2 B

(E) OFFICE

206-3 B

(E) OFFICE

207 B

(E) CONF. RM.

208 B

(E) CONF. RM.

209.1 B

(E)

CONFERENCE

ROOM

209-2 B

(E) MAIL RM

210 B

(E) PASSAGE

211 B

(E) CORRIDOR

200 B

01-03

01-04

01-04

A

B

C

PROJECT NO.

CHECKED

DRAWN

DESIGNER

DATE ARCHIVE NO.

DRAWING SHEET NO.

SHEET OF

REVISION

PROJECT NAME

DATEREVISION / ISSUENO.

REVISION DATE

REVISION DATE

REVISION DATE

United States Department of Agriculture Forest Service

DRAWING TITLE

FIRE LAB AIR

QUALITY &

ELECTRONIC LAB

5/

/2

4:

:1

P

M

D2.1

05.23.19

C O

N S

T R

U C

T

IO

N D

O C

U M

E N

T S

OVERALL

DEMOLITION PLANS

18075.00

SM

LY

SM/LY

GENERAL NOTES

KEYNOTES

LEGEND

01-02 ALT-2. B-WING WINDOW REPLACEMENT ENTIRE SOUTH ELEVATION 1ST FLOOR

01-03 ALT-3. B-WING WINDOW REPLACEMENT ENTIRE SOUTH ELEVATION 2ND FLOOR

01-04 ALT-4. HANDRAIL UPGRADE FOR STAIRWELLS IN B-WING TO MEET ADA/ABA, SEE

DETAIL (1/A2.1), (5/A2.1)

1/16" = 1'-0"6 OVERALL DEMOLITION FIRST FLOOR PLAN NORTH

0'16' 8' 16' 32'

NORTH

0'16' 8' 16' 32'1/16" = 1'-0"14 OVERALL DEMOLITION SECOND FLOOR PLANKEYPLAN AREA B AND C

C

E

F

91011

MOVE (E) FUME HOOD,

SEE ENLARGED PLANS.

01-03

02-02

02-02

02-02

02-02

02-02

02-02

02-02

(E)

INSTRUMENT

VAULT

114 B

02-26

02-26

02-07

02-14

(E) AEROSOLS

LAB

113 B

(E) OFFICE

113-1 B

(E)

INSTRUMENT

DEV. LAB

115 B

C

E

F

02-02

02-02

02-28

02-02

02-02

02-02

02-03 02-03

02-02

02-02

01-02

(E) RECIVING

& SHIPPING

106 B

02-26

02-07

02-08

ALIGN WITH LEFT WALL

02-13

02-12

02-14

(E) OFFICE

108B

(E) DARK

ROOM

108B

(E) OFFICE

110B

(E) OFFICE

111B

(E)110B.1

02-27

02-28

02-28

02-28

1. ASBESTOS ABATEMENT WILL BE REQUIRED BY THE GENERAL CONTRACTOR, REFER TO

REPORTS IN THE PROJECT MANUAL FOR ADDITIONAL INFO.

2. IT IS THE CONTRACTOR'S RESPONSIBILITY TO FAMILIARIZE HIMSELF/ HERSELF WITH THE SCOPE

OF WORK.

3. THE DEMOLITION NOTES PROVIDE A GENERAL DESCRIPTION OF THE ITEMS AND AREAS

REQUIRING REMOVAL. THE CONTRACTOR SHALL FIELD VERIFY ACTUAL QUANTITIES AND

LOCATIONS OF ALL INDICATED ITEMS AS NECESSARY TO COMPLETE THE SCOPE OF WORK IN

ACCORDANCE WITH THE CONTRACT DOCUMENTS.

4. COORDINATE WITH OWNER FOR ANY EQUIPMENT TO BE SALVAGED. UNLESS SPECIFICALLY

SCHEDULED FOR REUSE, DEMOLISHED MATERIALS SHALL BECOME THE POSSESSION OF THE

CONTRACTOR AND SHALL BE IMMEDIATELY REMOVED FROM THE SITE.

5. REMOVE MATERIALS FROM SITE AND DISPOSE OF IN A LEGAL MANNER AT NO ADDITIONAL

EXPENSE TO OWNER

6. DEBRIS FROM THE DEMOLITION SHALL NOT BE ALLOWED TO ACCUMULATE WITHIN THE BUILDING

OR ON THE SITE.

7. REMOVE FROM SITE ANY CONTAMINATED, VERMIN INFESTED, OR DANGEROUS MATERIALS

ENCOUNTERED AND DISPOSE OF BY SAFE MEANS SO AS NOT TO ENDANGER HEALTH OF

WORKERS AND PUBLIC.

8. BURNING OF MATERIALS ON SITE IS NOT PERMITTED.

9. CLEAN-UP: MUST MEET GOVERNING DUST CONTROL CODES.

10. NOTIFY AFFECTED UTILITY COMPANIES BEFORE STARTING WORK AND COMPLY WITH THEIR

REQUIREMENTS. INCLUDING FS CIO.

11. PREVENT MOVEMENT OR SETTLEMENT OF ADJACENT STRUCTURES. PROVIDE BRACING AND

SHORING.

12. CARRY OUT DEMOLITION WORK TO CAUSE AS LITTLE INCONVENIENCE TO ANY ADJACENT

OCCUPIED BUILDING OR SITE AS POSSIBLE AND WITH MINIMUM INTERFERENCE TO PUBLIC OR

PRIVATE ACCESSES. MAINTAIN PROTECTED EGRESS AND ACCESS AT ALL TIMES.

13. CONTRACTOR SHALL PROVIDE TEMPORARY DUST AND CONSTRUCTION SEPARATION WALLS AS

REQUIRED TO SHIELD THE PUBLIC FROM NOISE, DUST, WEATHER, AND OTHER HAZARDS THAT

MAY BE EXPOSED AS A RESULT OF THE DEMOLITION WORK.

14. PERFORM CUTTING OF EXISTING CONCRETE AND MASONRY WITH SAWS AND CORE DRILLS. DO

NOT USE JACK-HAMMERS EXCEPT WHERE PERMITTED BY OWNER.

15. BREAK CONCRETE AND MASONRY INTO SECTIONS LESS THAN 3 FEET IN ANY DIMENSION.

16. CONTRACTOR SHALL TAKE ALL NECESSARY PRECAUTIONS TO INSURE EXISTING STRUCTURAL

ELEMENTS REMAIN UNDAMAGED THROUGHOUT CONSTRUCTION, UNLESS SPECIFICALLY NOTED

ON DEMOLITION PLAN. IT IS THE SOLE RESPONSIBILITY OF THE CONTRACTOR TO IDENTIFY AND

PROVIDE ANY SHORING, BRACING, OR TEMPORARY STRUCTURE, AND TO COORDINATE WITH

STRUCTURAL ENGINEER AS REQUIRED.

17. IT IS THE OWNER'S INTENT TO OPERATE ON SITE THROUGHOUT CONSTRUCTION. CONTRACTOR

TO COORDINATE WITH OWNER ON PHASING, AND SCHEDULING OF WORK AS NOT TO CONFLICT

WITH THE AIRPORT OPERATIONS.

18. ALL PUBLIC UTILITIES TO REMAIN IN OPERATION THROUGHOUT CONSTRUCTION. CONTRACTOR

TO COORDINATE ANY TEMPORARY SERVICES REQUIRED TO MAINTAIN BUSINESS OPERATIONS.

19. SEE ENGINEERING DRAWINGS FOR DUCTWORK, DIFFUSER, PLENUM BOX, ETC. DEMOLITION

AND/OR PROTECTION. COORDINATE WITH MECHANICAL ENGINEER.

20. FIRE SAFETY MUST BE MAINTAINED FOR ALL PERSONNEL WORKING ON THE FLOOR. ALL FIRE

STAIRS, ALARMS, SPEAKERS, ETC. MUST REMAIN ACCESSIBLE AND OPERABLE AT ALL TIMES.

CONTRACTOR SHALL MAKE NECESSARY PROVISIONS TO PROTECT THIS EQUIPMENT.

IMMEDIATELY NOTIFY BUILDING SECURITY AND BUILDING MANAGER OF DAMAGED OR DISABLED

SYSTEMS AND REPAIR OR REPLACE DAMAGED SYSTEMS IMMEDIATELY. RELOCATION OF SMOKE

DETECTORS, PUBLIC ADDRESS SPEAKERS AND FIRE ALARM EQUIPMENT, NECESSITATED BY

NEW CONSTRUCTION, SHALL BE ACCOMPLISHED AS A FIRST PRIORITY, AND PER THE PLANS.

21. IF ANY QUESTIONS ARISE AS TO THE REMOVAL OF ANY MATERIAL, CLARIFY THE POINT IN

QUESTION WITH THE OWNER BEFORE PROCEEDING. IMMEDIATELY STOP WORK IF HAZARDOUS

MATERIALS ARE FOUND AND CONTACT THE OWNER'S REPRESENTATIVE.

22. REMOVAL OF ANY EQUIPMENT, CABLING SWITCHES, AND CONDUIT PERTAINING TO

DATA/COMMUNICATIONS AND TELEPHONE SHALL BE VERIFIED WITH TELEPHONE COMPANIES,

SERVICE OWNER OR TENANT DATA/COMMUNICATIONS REPRESENTATIVE AS REQUIRED TO

PREVENT NEW CONSTRUCTION DELAYS.

23. PROVIDE FOR FIRE PROOFING REPAIR AS REQUIRED AT STRUCTURAL STEEL, TO THE ORIGINAL

RATING WHERE CONSTRUCTION TRADES REMOVE EXISTING FIRE PROOFING. REPAIR ANY

DAMAGE OR PENETRATIONS IN RATED ASSEMBLIES TO CONFORM TO THEIR ORIGINAL LISTING

REQUIREMENTS AND TO MAINTAIN FIRE PROTECTION AND SEPARATION AS ORIGINALLY

DESIGNED.

24. AT COMPLETION OF DEMOLITION WORK, THE CONSTRUCTION AREA(S) SHALL BE LEFT IN "BROOM

CLEAN" CONDITION. ALL DEBRIS AND MISCELLANEOUS MATERIAL SHALL BE REMOVED.

25. CONTRACTOR SHALL BE RESPONSIBLE FOR PATCHING AND/OR REPAIRING ANY DAMAGE

CAUSED BY HIM OR HIS SUBCONTRACTORS. REFINISH TO MATCH EXISTING ADJACENT FINISH,

OR AS NOTED HEREIN.

26. FOR AREAS NOT IN DEMOLITION SCOPE OF WORK, PROTECT AS REQUIRED, ALL SURFACES, EQUIPMENT, FIXTURES AND HARDWARE DURING DEMOLITION AND/OR CONSTRUCTION.

27. PRIOR TO DEMOLITION, INVESTIGATE WALLS FOR CONCEALED PIPING AND INFORM

OWNER/ARCHITECT OF ANY CONDITION NOT DOCUMENTED IN CONTRACT DRAWINGS. DEMO

DESIGNATED WALL BASES, WALL FRAMING, BATT INSULATION AND GYPSUM BOARD. DEMO

CONDUITS AND RECEPTACLES, REFERENCE ELECTRICAL DEMO PLAN FOR ADDITIONAL

INFORMATION.

28. ALL EXISTING DIRECTIONAL SIGNAGE TO BE REMOVED UNLESS NOTED OTHERWISE.

29. WHERE NOTED, REMOVE FLOORING DOWN TO TOP OF CONC. SLAB, INCLUDING ADHESIVES,

TRANSITION STRIPS, AND OTHER ASSOCIATED ELEMENTS, TYP., UNLESS NOTED OTHERWISE.

PREPARE REMAINING SURFACES TO RECEIVE NEW FINISHES.

INDICATES BUILT ITEM TO BE REMOVED

DEMO (E) FLOOR FINISH

PROJECT NO.

CHECKED

DRAWN

DESIGNER

DATE ARCHIVE NO.

DRAWING SHEET NO.

SHEET OF

REVISION

PROJECT NAME

DATEREVISION / ISSUENO.

REVISION DATE

REVISION DATE

REVISION DATE

United States Department of Agriculture Forest Service

DRAWING TITLE

FIRE LAB AIR

QUALITY &

ELECTRONIC LAB

5/

/2

4:

:1

P

M

D3.1

05.23.19

C O

N S

T R

U C

T

IO

N D

O C

U M

E N

T S

DEMOLITION

ENLARGED PLAN

AREA B

18075.00

SM

LY

SM/LY

1/4" = 1'-0"14 LEVEL 1 DEMO - ENLARGED WEST

1/4" = 1'-0"5 LEVEL 1 DEMO - ENLARGED EAST

GENERAL NOTES

KEYNOTES

LEGEND

01-02 ALT-2. B-WING WINDOW REPLACEMENT ENTIRE SOUTH ELEVATION 1ST FLOOR

01-03 ALT-3. B-WING WINDOW REPLACEMENT ENTIRE SOUTH ELEVATION 2ND FLOOR

02-02 DEMO (E) CASEWORK

02-03 DEMO (E) SHELVING

02-07 DEMO (E) WALL PARTITION

02-08 REMOVE (E) DOOR / DOOR FRAME & SALVAGE FOR REUSE

02-12 (E) FUME HOOD TO REMAIN

02-13 DEMO (E) WALL FOR DOOR

02-14 DEMO (E) PLUMBING FIXTURE

02-26 REMOVE (E) DOOR / DOOR FRAME

02-27 DEMO (E) DI WATER UNIT AND RETURN TO GOVERNMENT

02-28 OWNER TO REMOVE SHELVING

NORTH

0'4' 2' 4' 8'

NORTH

0'4' 2' 4' 8'

D2.1

F

G

HH

JJ

(E) MAIL

ROOM

109 C

02-26

02-07

02-26

02-14

02-15

02-14

02-14

02-15

02-15

(E) MECH/ STOR

103 C

(E) OFFICE

107 C

(E) OFFICE

105 C

02-17

02-26

D3.2

D3.2

02-22

02-26

02-2602-26

02-26 02-08

02-0702-09

02-09

02-07

(E) SERVER

ROOM

106 C

(E) OFFICE

108 C

104 C

(E) CORRIDOR

(E) JANITOR

CLOSET

102A C

RESTROOM /

SHWR

102 C

(E) CORRIDOR

101 C

02-23

02-25

02-04

(E )1

C

.1

01-06 01-0601-06

01-06

01-06

01-06

01-06 01-06 01-06

01-06

1. ASBESTOS ABATEMENT WILL BE REQUIRED BY THE GENERAL CONTRACTOR, REFER TO

REPORTS IN THE PROJECT MANUAL FOR ADDITIONAL INFO.

2. IT IS THE CONTRACTOR'S RESPONSIBILITY TO FAMILIARIZE HIMSELF/ HERSELF WITH THE SCOPE

OF WORK.

3. THE DEMOLITION NOTES PROVIDE A GENERAL DESCRIPTION OF THE ITEMS AND AREAS

REQUIRING REMOVAL. THE CONTRACTOR SHALL FIELD VERIFY ACTUAL QUANTITIES AND

LOCATIONS OF ALL INDICATED ITEMS AS NECESSARY TO COMPLETE THE SCOPE OF WORK IN

ACCORDANCE WITH THE CONTRACT DOCUMENTS.

4. COORDINATE WITH OWNER FOR ANY EQUIPMENT TO BE SALVAGED. UNLESS SPECIFICALLY

SCHEDULED FOR REUSE, DEMOLISHED MATERIALS SHALL BECOME THE POSSESSION OF THE

CONTRACTOR AND SHALL BE IMMEDIATELY REMOVED FROM THE SITE.

5. REMOVE MATERIALS FROM SITE AND DISPOSE OF IN A LEGAL MANNER AT NO ADDITIONAL

EXPENSE TO OWNER

6. DEBRIS FROM THE DEMOLITION SHALL NOT BE ALLOWED TO ACCUMULATE WITHIN THE BUILDING

OR ON THE SITE.

7. REMOVE FROM SITE ANY CONTAMINATED, VERMIN INFESTED, OR DANGEROUS MATERIALS

ENCOUNTERED AND DISPOSE OF BY SAFE MEANS SO AS NOT TO ENDANGER HEALTH OF

WORKERS AND PUBLIC.

8. BURNING OF MATERIALS ON SITE IS NOT PERMITTED.

9. CLEAN-UP: MUST MEET GOVERNING DUST CONTROL CODES.

10. NOTIFY AFFECTED UTILITY COMPANIES BEFORE STARTING WORK AND COMPLY WITH THEIR

REQUIREMENTS. INCLUDING FS CIO.

11. PREVENT MOVEMENT OR SETTLEMENT OF ADJACENT STRUCTURES. PROVIDE BRACING AND

SHORING.

12. CARRY OUT DEMOLITION WORK TO CAUSE AS LITTLE INCONVENIENCE TO ANY ADJACENT

OCCUPIED BUILDING OR SITE AS POSSIBLE AND WITH MINIMUM INTERFERENCE TO PUBLIC OR

PRIVATE ACCESSES. MAINTAIN PROTECTED EGRESS AND ACCESS AT ALL TIMES.

13. CONTRACTOR SHALL PROVIDE TEMPORARY DUST AND CONSTRUCTION SEPARATION WALLS AS

REQUIRED TO SHIELD THE PUBLIC FROM NOISE, DUST, WEATHER, AND OTHER HAZARDS THAT

MAY BE EXPOSED AS A RESULT OF THE DEMOLITION WORK.

14. PERFORM CUTTING OF EXISTING CONCRETE AND MASONRY WITH SAWS AND CORE DRILLS. DO

NOT USE JACK-HAMMERS EXCEPT WHERE PERMITTED BY OWNER.

15. BREAK CONCRETE AND MASONRY INTO SECTIONS LESS THAN 3 FEET IN ANY DIMENSION.

16. CONTRACTOR SHALL TAKE ALL NECESSARY PRECAUTIONS TO INSURE EXISTING STRUCTURAL

ELEMENTS REMAIN UNDAMAGED THROUGHOUT CONSTRUCTION, UNLESS SPECIFICALLY NOTED

ON DEMOLITION PLAN. IT IS THE SOLE RESPONSIBILITY OF THE CONTRACTOR TO IDENTIFY AND

PROVIDE ANY SHORING, BRACING, OR TEMPORARY STRUCTURE, AND TO COORDINATE WITH

STRUCTURAL ENGINEER AS REQUIRED.

17. IT IS THE OWNER'S INTENT TO OPERATE ON SITE THROUGHOUT CONSTRUCTION. CONTRACTOR

TO COORDINATE WITH OWNER ON PHASING, AND SCHEDULING OF WORK AS NOT TO CONFLICT

WITH THE AIRPORT OPERATIONS.

18. ALL PUBLIC UTILITIES TO REMAIN IN OPERATION THROUGHOUT CONSTRUCTION. CONTRACTOR

TO COORDINATE ANY TEMPORARY SERVICES REQUIRED TO MAINTAIN BUSINESS OPERATIONS.

19. SEE ENGINEERING DRAWINGS FOR DUCTWORK, DIFFUSER, PLENUM BOX, ETC. DEMOLITION

AND/OR PROTECTION. COORDINATE WITH MECHANICAL ENGINEER.

20. FIRE SAFETY MUST BE MAINTAINED FOR ALL PERSONNEL WORKING ON THE FLOOR. ALL FIRE

STAIRS, ALARMS, SPEAKERS, ETC. MUST REMAIN ACCESSIBLE AND OPERABLE AT ALL TIMES.

CONTRACTOR SHALL MAKE NECESSARY PROVISIONS TO PROTECT THIS EQUIPMENT.

IMMEDIATELY NOTIFY BUILDING SECURITY AND BUILDING MANAGER OF DAMAGED OR DISABLED

SYSTEMS AND REPAIR OR REPLACE DAMAGED SYSTEMS IMMEDIATELY. RELOCATION OF SMOKE

DETECTORS, PUBLIC ADDRESS SPEAKERS AND FIRE ALARM EQUIPMENT, NECESSITATED BY

NEW CONSTRUCTION, SHALL BE ACCOMPLISHED AS A FIRST PRIORITY, AND PER THE PLANS.

21. IF ANY QUESTIONS ARISE AS TO THE REMOVAL OF ANY MATERIAL, CLARIFY THE POINT IN

QUESTION WITH THE OWNER BEFORE PROCEEDING. IMMEDIATELY STOP WORK IF HAZARDOUS

MATERIALS ARE FOUND AND CONTACT THE OWNER'S REPRESENTATIVE.

22. REMOVAL OF ANY EQUIPMENT, CABLING SWITCHES, AND CONDUIT PERTAINING TO

DATA/COMMUNICATIONS AND TELEPHONE SHALL BE VERIFIED WITH TELEPHONE COMPANIES,

SERVICE OWNER OR TENANT DATA/COMMUNICATIONS REPRESENTATIVE AS REQUIRED TO

PREVENT NEW CONSTRUCTION DELAYS.

23. PROVIDE FOR FIRE PROOFING REPAIR AS REQUIRED AT STRUCTURAL STEEL, TO THE ORIGINAL

RATING WHERE CONSTRUCTION TRADES REMOVE EXISTING FIRE PROOFING. REPAIR ANY

DAMAGE OR PENETRATIONS IN RATED ASSEMBLIES TO CONFORM TO THEIR ORIGINAL LISTING

REQUIREMENTS AND TO MAINTAIN FIRE PROTECTION AND SEPARATION AS ORIGINALLY

DESIGNED.

24. AT COMPLETION OF DEMOLITION WORK, THE CONSTRUCTION AREA(S) SHALL BE LEFT IN "BROOM

CLEAN" CONDITION. ALL DEBRIS AND MISCELLANEOUS MATERIAL SHALL BE REMOVED.

25. CONTRACTOR SHALL BE RESPONSIBLE FOR PATCHING AND/OR REPAIRING ANY DAMAGE

CAUSED BY HIM OR HIS SUBCONTRACTORS. REFINISH TO MATCH EXISTING ADJACENT FINISH,

OR AS NOTED HEREIN.

26. FOR AREAS NOT IN DEMOLITION SCOPE OF WORK, PROTECT AS REQUIRED, ALL SURFACES, EQUIPMENT, FIXTURES AND HARDWARE DURING DEMOLITION AND/OR CONSTRUCTION.

27. PRIOR TO DEMOLITION, INVESTIGATE WALLS FOR CONCEALED PIPING AND INFORM

OWNER/ARCHITECT OF ANY CONDITION NOT DOCUMENTED IN CONTRACT DRAWINGS. DEMO

DESIGNATED WALL BASES, WALL FRAMING, BATT INSULATION AND GYPSUM BOARD. DEMO

CONDUITS AND RECEPTACLES, REFERENCE ELECTRICAL DEMO PLAN FOR ADDITIONAL

INFORMATION.

28. ALL EXISTING DIRECTIONAL SIGNAGE TO BE REMOVED UNLESS NOTED OTHERWISE.

29. WHERE NOTED, REMOVE FLOORING DOWN TO TOP OF CONC. SLAB, INCLUDING ADHESIVES,

TRANSITION STRIPS, AND OTHER ASSOCIATED ELEMENTS, TYP., UNLESS NOTED OTHERWISE.

PREPARE REMAINING SURFACES TO RECEIVE NEW FINISHES.

INDICATES BUILT ITEM TO BE REMOVED

DEMO (E) FLOOR FINISH

LEVEL 1

100' - 0"

LEVEL 2

111' - 8"

02-07 02-1902-0602-21 02-0402-07

01-06 01-06

PROJECT NO.

CHECKED

DRAWN

DESIGNER

DATE ARCHIVE NO.

DRAWING SHEET NO.

SHEET OF

REVISION

PROJECT NAME

DATEREVISION / ISSUENO.

REVISION DATE

REVISION DATE

REVISION DATE

United States Department of Agriculture Forest Service

DRAWING TITLE

FIRE LAB AIR

QUALITY &

ELECTRONIC LAB

5/

/2

4:

:1

P

M

D3.2

05.23.19

C O

N S

T R

U C

T

IO

N D

O C

U M

E N

T S

DEMOLITION

ENLARGED PLAN /

SECTION AREA C

18075.00

SM

LY

SM/LY

NORTH

0'4' 2' 4' 8'

GENERAL NOTES

KEYNOTES

LEGEND

01-06

02-04

02-06

02-07

02-08

02-09

02-14

02-15

02-17

02-19

02-21

02-22

02-23

02-25

02-26

NOT USED

DEMO (E) STOREFRONT WINDOW

DEMO (E) SUSPENDED CEILING

DEMO (E) WALL PARTITION

REMOVE (E) DOOR / DOOR FRAME & SALVAGE FOR REUSE

DEMO (E) BORROWED LITE & GLAZING

DEMO (E) PLUMBING FIXTURE

DEMO (E) SHOWER AND ENCLOSURE

DEMO (E) COMPRESSOR AND STEEL ENCLOSURE, REF MECH.

DEMO (E) LIGHTWELL

DEMO (E) SKYLIGHT

DEMO (E) RAISED FLOOR

SAWCUT (E) CONCRETE FLOOR FOR NEW PLUMBING FIXTURES. SEE

PLUMBING DEMO (E) FURRING WALL OVER STOREFRONT WINDOW

REMOVE (E) DOOR / DOOR FRAME

1/4" = 1'-0"10 LEVEL 1 DEMO - ENLARGED AREA C

1/4" = 1'-0"14 AREA C DEMO SECTION

1. ASBESTOS ABATEMENT WILL BE REQUIRED BY THE GENERAL CONTRACTOR, REFER TO

REPORTS IN THE PROJECT MANUAL FOR ADDITIONAL INFO.

2. IT IS THE CONTRACTOR'S RESPONSIBILITY TO FAMILIARIZE HIMSELF/ HERSELF WITH THE SCOPE

OF WORK.

3. THE DEMOLITION NOTES PROVIDE A GENERAL DESCRIPTION OF THE ITEMS AND AREAS

REQUIRING REMOVAL. THE CONTRACTOR SHALL FIELD VERIFY ACTUAL QUANTITIES AND

LOCATIONS OF ALL INDICATED ITEMS AS NECESSARY TO COMPLETE THE SCOPE OF WORK IN

ACCORDANCE WITH THE CONTRACT DOCUMENTS.

4. COORDINATE WITH OWNER FOR ANY EQUIPMENT TO BE SALVAGED. UNLESS SPECIFICALLY

SCHEDULED FOR REUSE, DEMOLISHED MATERIALS SHALL BECOME THE POSSESSION OF THE

CONTRACTOR AND SHALL BE IMMEDIATELY REMOVED FROM THE SITE.

5. REMOVE MATERIALS FROM SITE AND DISPOSE OF IN A LEGAL MANNER AT NO ADDITIONAL

EXPENSE TO OWNER

6. DEBRIS FROM THE DEMOLITION SHALL NOT BE ALLOWED TO ACCUMULATE WITHIN THE BUILDING

OR ON THE SITE.

7. REMOVE FROM SITE ANY CONTAMINATED, VERMIN INFESTED, OR DANGEROUS MATERIALS

ENCOUNTERED AND DISPOSE OF BY SAFE MEANS SO AS NOT TO ENDANGER HEALTH OF

WORKERS AND PUBLIC.

8. BURNING OF MATERIALS ON SITE IS NOT PERMITTED.

9. CLEAN-UP: MUST MEET GOVERNING DUST CONTROL CODES.

10. NOTIFY AFFECTED UTILITY COMPANIES BEFORE STARTING WORK AND COMPLY WITH THEIR

REQUIREMENTS. INCLUDING FS CIO.

11. PREVENT MOVEMENT OR SETTLEMENT OF ADJACENT STRUCTURES. PROVIDE BRACING AND

SHORING.

12. CARRY OUT DEMOLITION WORK TO CAUSE AS LITTLE INCONVENIENCE TO ANY ADJACENT

OCCUPIED BUILDING OR SITE AS POSSIBLE AND WITH MINIMUM INTERFERENCE TO PUBLIC OR

PRIVATE ACCESSES. MAINTAIN PROTECTED EGRESS AND ACCESS AT ALL TIMES.

13. CONTRACTOR SHALL PROVIDE TEMPORARY DUST AND CONSTRUCTION SEPARATION WALLS AS

REQUIRED TO SHIELD THE PUBLIC FROM NOISE, DUST, WEATHER, AND OTHER HAZARDS THAT

MAY BE EXPOSED AS A RESULT OF THE DEMOLITION WORK.

14. PERFORM CUTTING OF EXISTING CONCRETE AND MASONRY WITH SAWS AND CORE DRILLS. DO

NOT USE JACK-HAMMERS EXCEPT WHERE PERMITTED BY OWNER.

15. BREAK CONCRETE AND MASONRY INTO SECTIONS LESS THAN 3 FEET IN ANY DIMENSION.

16. CONTRACTOR SHALL TAKE ALL NECESSARY PRECAUTIONS TO INSURE EXISTING STRUCTURAL

ELEMENTS REMAIN UNDAMAGED THROUGHOUT CONSTRUCTION, UNLESS SPECIFICALLY NOTED

ON DEMOLITION PLAN. IT IS THE SOLE RESPONSIBILITY OF THE CONTRACTOR TO IDENTIFY AND

PROVIDE ANY SHORING, BRACING, OR TEMPORARY STRUCTURE, AND TO COORDINATE WITH

STRUCTURAL ENGINEER AS REQUIRED.

17. IT IS THE OWNER'S INTENT TO OPERATE ON SITE THROUGHOUT CONSTRUCTION. CONTRACTOR

TO COORDINATE WITH OWNER ON PHASING, AND SCHEDULING OF WORK AS NOT TO CONFLICT

WITH THE AIRPORT OPERATIONS.

18. ALL PUBLIC UTILITIES TO REMAIN IN OPERATION THROUGHOUT CONSTRUCTION. CONTRACTOR

TO COORDINATE ANY TEMPORARY SERVICES REQUIRED TO MAINTAIN BUSINESS OPERATIONS.

19. SEE ENGINEERING DRAWINGS FOR DUCTWORK, DIFFUSER, PLENUM BOX, ETC. DEMOLITION

AND/OR PROTECTION. COORDINATE WITH MECHANICAL ENGINEER.

20. FIRE SAFETY MUST BE MAINTAINED FOR ALL PERSONNEL WORKING ON THE FLOOR. ALL FIRE

STAIRS, ALARMS, SPEAKERS, ETC. MUST REMAIN ACCESSIBLE AND OPERABLE AT ALL TIMES.

CONTRACTOR SHALL MAKE NECESSARY PROVISIONS TO PROTECT THIS EQUIPMENT.

IMMEDIATELY NOTIFY BUILDING SECURITY AND BUILDING MANAGER OF DAMAGED OR DISABLED

SYSTEMS AND REPAIR OR REPLACE DAMAGED SYSTEMS IMMEDIATELY. RELOCATION OF SMOKE

DETECTORS, PUBLIC ADDRESS SPEAKERS AND FIRE ALARM EQUIPMENT, NECESSITATED BY

NEW CONSTRUCTION, SHALL BE ACCOMPLISHED AS A FIRST PRIORITY, AND PER THE PLANS.

21. IF ANY QUESTIONS ARISE AS TO THE REMOVAL OF ANY MATERIAL, CLARIFY THE POINT IN

QUESTION WITH THE OWNER BEFORE PROCEEDING. IMMEDIATELY STOP WORK IF HAZARDOUS

MATERIALS ARE FOUND AND CONTACT THE OWNER'S REPRESENTATIVE.

22. REMOVAL OF ANY EQUIPMENT, CABLING SWITCHES, AND CONDUIT PERTAINING TO

DATA/COMMUNICATIONS AND TELEPHONE SHALL BE VERIFIED WITH TELEPHONE COMPANIES,

SERVICE OWNER OR TENANT DATA/COMMUNICATIONS REPRESENTATIVE AS REQUIRED TO

PREVENT NEW CONSTRUCTION DELAYS.

23. PROVIDE FOR FIRE PROOFING REPAIR AS REQUIRED AT STRUCTURAL STEEL, TO THE ORIGINAL

RATING WHERE CONSTRUCTION TRADES REMOVE EXISTING FIRE PROOFING. REPAIR ANY

DAMAGE OR PENETRATIONS IN RATED ASSEMBLIES TO CONFORM TO THEIR ORIGINAL LISTING

REQUIREMENTS AND TO MAINTAIN FIRE PROTECTION AND SEPARATION AS ORIGINALLY

DESIGNED.

24. AT COMPLETION OF DEMOLITION WORK, THE CONSTRUCTION AREA(S) SHALL BE LEFT IN "BROOM

CLEAN" CONDITION. ALL DEBRIS AND MISCELLANEOUS MATERIAL SHALL BE REMOVED.

25. CONTRACTOR SHALL BE RESPONSIBLE FOR PATCHING AND/OR REPAIRING ANY DAMAGE

CAUSED BY HIM OR HIS SUBCONTRACTORS. REFINISH TO MATCH EXISTING ADJACENT FINISH,

OR AS NOTED HEREIN.

26. FOR AREAS NOT IN DEMOLITION SCOPE OF WORK, PROTECT AS REQUIRED, ALL SURFACES, EQUIPMENT, FIXTURES AND HARDWARE DURING DEMOLITION AND/OR CONSTRUCTION.

27. PRIOR TO DEMOLITION, INVESTIGATE WALLS FOR CONCEALED PIPING AND INFORM

OWNER/ARCHITECT OF ANY CONDITION NOT DOCUMENTED IN CONTRACT DRAWINGS. DEMO

DESIGNATED WALL BASES, WALL FRAMING, BATT INSULATION AND GYPSUM BOARD. DEMO

CONDUITS AND RECEPTACLES, REFERENCE ELECTRICAL DEMO PLAN FOR ADDITIONAL

INFORMATION.

28. ALL EXISTING DIRECTIONAL SIGNAGE TO BE REMOVED UNLESS NOTED OTHERWISE.

29. WHERE NOTED, REMOVE FLOORING DOWN TO TOP OF CONC. SLAB, INCLUDING ADHESIVES,

TRANSITION STRIPS, AND OTHER ASSOCIATED ELEMENTS, TYP., UNLESS NOTED OTHERWISE.

PREPARE REMAINING SURFACES TO RECEIVE NEW FINISHES.

A

C

E

F

G

H

J

789101112

(E) WOMENS

RR

127 B

(E) MEN'S RR

126 B

(E) RECIVING

& SHIPPING

106 B

(E)

INSTRUMENT

VAULT

114 B

(E) LOBBY &

DISPLAY

101 B

(E) OFFICE

118 B

(E) OFFICE

119 B

(E) OFFICE

120 B

(E) OFFICE

121 B

(E) OFFICE

122 B

(E) OFFICE

123 B

(E) OFFICE

124 B

(E) OFFICE

125 B

02-21

02-19

(E) OFFICE

108B

(E) DARK

ROOM

108B

(E) OFFICE

110B

(E) OFFICE

111B

(E)

INSTRUMENT

CALIBRATION

113 B

(E) OFFICE

113-1 B

(E)

INSTRUMENT

DEV. LAB

115 B

D3.2

D3.2

(E) OFFICE (E) OFFICE

(E) SERVER

ROOM

(E) OFFICE

(E) CORRIDOR

(E) JANITOR

CLO(E) MAIL

ROOM

109 C 102A C

(E) MECH /

STOR

103C

RESTROOM /

SHWR

102 C

(E) CORRIDOR

101 C

104 C

105 C 107 C

108 C 106 C

DEMO (E) ACOUSTIC CEILING TILE & SUSPENSION SYSTEM

INDICATES BUILT ITEM TO BE REMOVED

A

B

C

PROJECT NO.

CHECKED

DRAWN

DESIGNER

DATE ARCHIVE NO.

DRAWING SHEET NO.

SHEET OF

REVISION

PROJECT NAME

DATEREVISION / ISSUENO.

REVISION DATE

REVISION DATE

REVISION DATE

United States Department of Agriculture Forest Service

DRAWING TITLE

FIRE LAB AIR

QUALITY &

ELECTRONIC LAB

5/

/2

4:

:1

P

M

D7.1

05.23.19

C O

N S

T R

U C

T

IO

N D

O C

U M

E N

T S

DEMOLITION RCP

18075.00

SM

LY

SM/LY

GENERAL NOTES

KEYNOTES

LEGEND

1/8" = 1'-0"9 DEMOLITION FIRST FLOOR REFLECTED CEILING PLAN NORTH

0'8' 4' 8' 16'

KEYPLAN AREA B AND C

02-19 DEMO (E) LIGHTWELL

02-21 DEMO (E) SKYLIGHT

P F

1. REFER TO STRUCTURAL, MECHANICAL, AND ELECTRICAL DRAWINGS FOR ADDITIONAL

INFORMATION. ALL INFORMATION REGARDING EXISTING CONDITIONS IS BASED UPON

OWNER-SUPPLIED DOCUMENTS AND MAY NOT PRECISELY REFLECT FIELD CONDITIONS.

2. THE CONTRACTOR SHALL NOT CONSIDER CONSTRUCTION NOTES TO BE ALL-INCLUSIVE.

IT IS THE CONTRACTOR'S RESPONSIBILITY TO INSPECT AND ASSESS EACH AREA AND TO

FULFILL THE INTENT OF THE CONTRACT DOCUMENTS. CONTRACTOR SHALL

COORDINATE ARCHITECTURAL CONSTRUCTION DRAWING AND NOTES WITH CIVIL,

STRUCTURAL AND MECHANICAL, ELECTRICAL & PLUMBING NOTES AND DRAWINGS.

3. FIELD VERIFY ALL DIMENSIONS. DO NOT SCALE DRAWINGS.

4. ALL FINISHES AND MATERIALS SHALL BE PROPERLY INTEGRATED TO ENSURE A

UNIFORM APPEARANCE AND SEAMLESS TRANSITION.

5. PROVIDE ALL BACKING FOR MILLWORK, GRAB BARS, AND ANY AND ALL WALL MOUNTED

EQUIPMENT OR ACCESSORIES; COORDINATE LOCATIONS.

6. ALL DIMENSIONS ARE FROM STRUCTURAL OR UNFINISHED FACE OF STUD, UNLESS

OTHERWISE NOTED.

7. GENERAL CONTRACTOR SHALL COORDINATE ALL ASPECTS OF THE BUILDING

CONSTRUCTION.

8. PROVIDE A SMOOTH AND LEVEL FINISH FLOOR, TYP. PATCH AND REPAIR ALL

INCONSISTENCIES IN FLOOR ELEVATIONS.

9. PATCH AND REPAIR ANY / ALL WALL SURFACES AS REQUIRED TO PROVIDE SUITABLE

SUBSTRATE FOR FINISHES.

10. U.L. ASSEMBLIES DESCRIBED ARE FOR REFERENCE ONLY. THE GENERAL CONTRACTOR

SHALL COORDINATE AND VERIFY THE INSTALLATION OF THE DESCRIBED SYSTEM(S) .

11. REFER TO DOOR SCHEDULE FOR ADDITIONAL INFORMATION.

12. LOCATE THE HINGE SIDE JAMB OF DOORS 6" FROM ADJACENT PERPENDICULAR WALL,

UNLESS NOTED OTHERWISE.

13. PROVIDE ACOUSTICAL SEALANT AROUND WALL EDGES, TOP AND BOTTOM, AND

PENETRATIONS, AND INSTALL PUTTY PADS AROUND ELECTRICAL BOXES WHERE

PARTITION CONTAINS ACOUSTICAL INSULATION.

A

C

E

F

123456

G

H

J

789101112

AEROSOLS

LAB

113 B

(E)

INSTRUMENT

VAULT

114 B

ELECTRONICS

LAB

115 B

GC LAB

112 B CONF RM./

LIBRARY

108 B

KITCHENETTE

109 B

A3.1

A3.1

A3.2

(E) OFFICE

129 B

(E) OFFICE

128 B

(E) OFFICE

104 B

(E) OFFICE

105 B

(E) RECIVING

& SHIPPING

106 B

OPEN OFFICE

108 C

(E) LOBBY &

DISPLAY

101 B

(E) OFFICE

118 B

(E) OFFICE

119 B

(E) OFFICE

120 B

(E) OFFICE

121 B

(E) OFFICE

122 B

(E) OFFICE

123 B

(E) OFFICE

124 B

(E) OFFICE

125 B

(E) MEN'S RR

126 B

(E) WOMENS

RR

127 B

A3.2F

A3.1F

A3.1F

(E) MAIL

ROOM

109 C

SERVER

ROOM

106 C

01-04

01-04

A

C

E

F

123456789101112

DN

D N

(E) OFFICE

212 B

(E) OFFICE

213 B

(E) OFFICE

211 B

(E) OFFICE

215 B

(E) OFFICE

216 B

(E) OFFICE

217 B

(E) OFFICE

218 B

(E) OFFICE

219 B

(E) OFFICE

220 B

(E) MENS

221 B

(E) WOMEN

222 B

(E) OFFICE

223 B

(E) OFFICE

224 B

(E) OFFICE

201 B

(E) OFFFICE

203 B

(E) STOCK

ROOM

204 B

(E) OFFICE

206-2 B

(E) OFFICE

206-1 B

(E) OFFICE

206-3 B

(E) OFFICE

207 B

(E) CONF. RM.

208 B

(E) CONF. RM.

209.1 B

(E)

CONFERENCE

ROOM

209-2 B

(E) MAIL RM

210 B

(E) PASSAGE

211 B

(E) CORRIDOR

200 B

01-04

01-04

ALT 1 - NEW TILE CARPETING, REF ROOM FINISH SCHED FOR ADD'L INFO.

REFERENCE ENLARGED FLOOR FINISH PLAN FOR BASE BID TILE CARPETING

A

B

C

1' - 0"1' - 0"

3'

WRAP HANDRAIL AROUND INSIDE

WALL AT STAIR RETURN MEZZANINE

1' - 0"

1' - 0"

WRAP HANDRAIL AROUND

INSIDE WALL AT STAIR

RETURN MEZZANINE

T Y

P

0'

/2

PROJECT NO.

CHECKED

DRAWN

DESIGNER

DATE ARCHIVE NO.

DRAWING SHEET NO.

SHEET OF

REVISION

PROJECT NAME

DATEREVISION / ISSUENO.

REVISION DATE

REVISION DATE

REVISION DATE

United States Department of Agriculture Forest Service

DRAWING TITLE

FIRE LAB AIR

QUALITY &

ELECTRONIC LAB

5/

/2

4:

:0

P

M

A2.1

05.23.19

C O

N S

T R

U C

T

IO

N D

O C

U M

E N

T S

OVERALL

CONSTRUCTION

FLOOR PLANS

18075.00

SM

LY

SM/LY

GENERAL NOTES

KEYNOTES

LEGEND

01-04 ALT-4. HANDRAIL UPGRADE FOR STAIRWELLS IN B-WING TO MEET

ADA/ABA, SEE DETAIL (1/A2.1), (5/A2.1)

NORTH

0'16' 8' 16' 32'

1/16" = 1'-0"6 OVERALL CONSTRUCTION FIRST FLOOR PLAN NORTH

0'16' 8' 16' 32'

1/16" = 1'-0"14 OVERALL CONSTRUCTION SECOND FLOOR PLANKEYPLAN AREA B AND C

3/8" = 1'-0"1 STAIR HANDRAIL SECTION ALT-4

3/8" = 1'-0"5 STAIR HANDRAIL PLAN ALT-4

E

A6.1

A6.1

5 2

A6.1

CONF RM./

LIBRARY

108 B

GC LAB

112 B

KITCHENETTE

109 B

230 V230 V230 V230 V

(E) FUME HOOD12-06

12-07

12-08

02-05

11-01

11-02

230 V

9B

.1(FUTURE) FUME

HOOD

A6.1 9

A6.1 10

A6.1

A-3

22-03

02-20

11-05 11-05 11-05

11-02

10-20

11-07

11-02 11-02

12-07 12-07

CL CL CL

2' - 1" 8' - 2" 5' - 0" 2' - 10" 5' - 0" 2' - 10" 5' - 0" 2' - 10" 6' - 5" 2' - 1"

/4

2'

2'

9' - 0"

C

E

F

91011

A6.2

12 10

A6.2

8AEROSOLS

LAB

113 B

(E)

INSTRUMENT

VAULT

114 B

ELECTRONICS

LAB

115 B

12-04

230 V230 V

A6.2

A6.2

A6.2

A6.2

A6.2

A6.2

11-02

11-02

12-04

23-02

A-3

10-2010-20

02-12

11-05

6' - 2"

2'

0"

8'

2'

2' - 1" 13' - 10"20' - 2" 2' - 1"

14' - 2"

2'

0"

9' - 2"

2'

3'

2' - 1"

1. REFER TO STRUCTURAL, MECHANICAL, AND ELECTRICAL DRAWINGS FOR ADDITIONAL

INFORMATION. ALL INFORMATION REGARDING EXISTING CONDITIONS IS BASED UPON

OWNER-SUPPLIED DOCUMENTS AND MAY NOT PRECISELY REFLECT FIELD CONDITIONS.

2. THE CONTRACTOR SHALL NOT CONSIDER CONSTRUCTION NOTES TO BE ALL-INCLUSIVE.

IT IS THE CONTRACTOR'S RESPONSIBILITY TO INSPECT AND ASSESS EACH AREA AND TO

FULFILL THE INTENT OF THE CONTRACT DOCUMENTS. CONTRACTOR SHALL

COORDINATE ARCHITECTURAL CONSTRUCTION DRAWING AND NOTES WITH CIVIL,

STRUCTURAL AND MECHANICAL, ELECTRICAL & PLUMBING NOTES AND DRAWINGS.

3. FIELD VERIFY ALL DIMENSIONS. DO NOT SCALE DRAWINGS.

4. ALL FINISHES AND MATERIALS SHALL BE PROPERLY INTEGRATED TO ENSURE A

UNIFORM APPEARANCE AND SEAMLESS TRANSITION.

5. PROVIDE ALL BACKING FOR MILLWORK, GRAB BARS, AND ANY AND ALL WALL MOUNTED

EQUIPMENT OR ACCESSORIES; COORDINATE LOCATIONS.

6. ALL DIMENSIONS ARE FROM STRUCTURAL OR UNFINISHED FACE OF STUD, UNLESS

OTHERWISE NOTED.

7. GENERAL CONTRACTOR SHALL COORDINATE ALL ASPECTS OF THE BUILDING

CONSTRUCTION.

8. PROVIDE A SMOOTH AND LEVEL FINISH FLOOR, TYP. PATCH AND REPAIR ALL

INCONSISTENCIES IN FLOOR ELEVATIONS.

9. PATCH AND REPAIR ANY / ALL WALL SURFACES AS REQUIRED TO PROVIDE SUITABLE

SUBSTRATE FOR FINISHES.

10. U.L. ASSEMBLIES DESCRIBED ARE FOR REFERENCE ONLY. THE GENERAL CONTRACTOR

SHALL COORDINATE AND VERIFY THE INSTALLATION OF THE DESCRIBED SYSTEM(S) .

11. REFER TO DOOR SCHEDULE FOR ADDITIONAL INFORMATION.

12. LOCATE THE HINGE SIDE JAMB OF DOORS 6" FROM ADJACENT PERPENDICULAR WALL,

UNLESS NOTED OTHERWISE.

13. PROVIDE ACOUSTICAL SEALANT AROUND WALL EDGES, TOP AND BOTTOM, AND

PENETRATIONS, AND INSTALL PUTTY PADS AROUND ELECTRICAL BOXES WHERE

PARTITION CONTAINS ACOUSTICAL INSULATION.

ITEM ABOVE

EXISTING WALL

NEW WALL

SYMBOL:

3 1/2" (3)

IF INFILL MATCH (E) WALL THICKNESS

A-3

A SERIES PARTITION

A

FIN. FLOOR, TYP.

UNDERSIDE OF DECK

OR BEAM ABOVE, TYP.

CONT. SEALANT

BOTH SIDES, TYP.

CONT. SEALANT

BOTH SIDES, TYP.

METAL STUD W/ 5/8"

IMPACT RESISTANT

GYP. BOARD EACH

SIDE

SLIP TRACK

PROJECT NO.

CHECKED

DRAWN

DESIGNER

DATE ARCHIVE NO.

DRAWING SHEET NO.

SHEET OF

REVISION

PROJECT NAME

DATEREVISION / ISSUENO.

REVISION DATE

REVISION DATE

REVISION DATE

United States Department of Agriculture Forest Service

DRAWING TITLE

FIRE LAB AIR

QUALITY &

ELECTRONIC LAB

5/

/2

4:

:0

P

M

A3.1

05.23.19

C O

N S

T R

U C

T

IO

N D

O C

U M

E N

T S

ENLARGED PLANS

AREA B

18075.00

SM

LY

SM/LY

1/4" = 1'-0"5 ENLARGED PLAN EAST

1/4" = 1'-0"13 ENLARGED PLAN WEST

GENERAL NOTES

KEYNOTES

LEGEND

02-05 REUSE (E) REFRIGERATOR

02-12 (E) FUME HOOD TO REMAIN

02-20 INFILL (E) DOOR OPENING TO MATCH (E) WALL

10-20 2-A RATED FIRE EXTINGUISHER W/ CABINET

11-01 DI WATER SYSTEM, OWNER SUPPLIED

11-02 SNORKEL FUME HOOD

11-05 GAS CYLINDER RACK, (ALT-6)

11-07 UNDERCOUNTER LAB FRIDGE, OWNER SUPPLIED

12-04 ISLAND WOOD LAB CASEWORK

12-06 FULL HEIGHT CABINETS

12-07 34" WIDE WORK SURFACE, EPOXY RESIN

12-08 EPOXY RESIN COUNTERTOPS

22-03 EMERGENCY EYE WASH STATION / SHOWER

23-02 (E) FUME HOOD, NEW LOCATION

NORTH

0'4' 2' 4' 8'

NORTH

0'4' 2' 4' 8'

A2.1

C

E

CONF RM./

LIBRARY

108 B

GC LAB

112 B

KITCHENETTE

109 B

9B

.1

(E) RECIVING

& SHIPPING

106 B

09-03

C

E

F

91011

AEROSOLS

LAB

113 B

(E)

INSTRUMENT

VAULT

114 B

ELECTRONICS

LAB

115 B

09-03

09-03

CT-1, CERAMIC TILING

SCRF-1, STATIC-CONTROL RESILIENT FLOORING

TC-1, TILE CARPETING

PROJECT NO.

CHECKED

DRAWN

DESIGNER

DATE ARCHIVE NO.

DRAWING SHEET NO.

SHEET OF

REVISION

PROJECT NAME

DATEREVISION / ISSUENO.

REVISION DATE

REVISION DATE

REVISION DATE

United States Department of Agriculture Forest Service

DRAWING TITLE

FIRE LAB AIR

QUALITY &

ELECTRONIC LAB

5/

/2

4:

:0

P

M

A3.1F

05.23.19

C O

N S

T R

U C

T

IO

N D

O C

U M

E N

T S

FLOOR FINISH

PLANS AREA B

18075.00

SM

LY

SM/LY

1/4" = 1'-0"5 ENLARGED EAST FINISH FLOOR PLAN

1/4" = 1'-0"13 ENLARGED WEST FINISH FLOOR PLAN

NORTH

0'4' 2' 4' 8'

NORTH

0'4' 2' 4' 8'

KEYNOTES

LEGEND

09-03 CONTINUE FLOORING UNDER SINK CASEWORK

GG

HH

JJ

A6.3

5(E) MAIL

ROOM

109 C

22-02

RESTROOM /

SHWR

102 C

10-02

10-01 10-11

02-20

(E) MECH /

STOR

103C

(E) CORRIDOR

101 C

24' - 3 1/2"

OPEN OFFICE

108 C

A5.1

A5.1

SERVER

ROOM

106 C

ALIGN (N) WALL W/

(E) DEMOLISHED

WALL

3'

M

IN

8' - 5" 3' - 6" 5' - 10"

A6.3

A6.3

A-3

A-3

6C

.1

2.

1C .1

102C.1

B-4

B-4 B-4

JANITOR

102.1 C

A3.2

A3.2

A3.2

10-21

10-20

3' - 2"

3'

/4

A5.1

1/

4"

ITEM ABOVE

EXISTING WALL

NEW WALL

1. REFER TO STRUCTURAL, MECHANICAL, AND ELECTRICAL DRAWINGS FOR ADDITIONAL

INFORMATION. ALL INFORMATION REGARDING EXISTING CONDITIONS IS BASED UPON

OWNER-SUPPLIED DOCUMENTS AND MAY NOT PRECISELY REFLECT FIELD CONDITIONS.

2. THE CONTRACTOR SHALL NOT CONSIDER CONSTRUCTION NOTES TO BE ALL-INCLUSIVE.

IT IS THE CONTRACTOR'S RESPONSIBILITY TO INSPECT AND ASSESS EACH AREA AND TO

FULFILL THE INTENT OF THE CONTRACT DOCUMENTS. CONTRACTOR SHALL

COORDINATE ARCHITECTURAL CONSTRUCTION DRAWING AND NOTES WITH CIVIL,

STRUCTURAL AND MECHANICAL, ELECTRICAL & PLUMBING NOTES AND DRAWINGS.

3. FIELD VERIFY ALL DIMENSIONS. DO NOT SCALE DRAWINGS.

4. ALL FINISHES AND MATERIALS SHALL BE PROPERLY INTEGRATED TO ENSURE A

UNIFORM APPEARANCE AND SEAMLESS TRANSITION.

5. PROVIDE ALL BACKING FOR MILLWORK, GRAB BARS, AND ANY AND ALL WALL MOUNTED

EQUIPMENT OR ACCESSORIES; COORDINATE LOCATIONS.

6. ALL DIMENSIONS ARE FROM STRUCTURAL OR UNFINISHED FACE OF STUD, UNLESS

OTHERWISE NOTED.

7. GENERAL CONTRACTOR SHALL COORDINATE ALL ASPECTS OF THE BUILDING

CONSTRUCTION.

8. PROVIDE A SMOOTH AND LEVEL FINISH FLOOR, TYP. PATCH AND REPAIR ALL

INCONSISTENCIES IN FLOOR ELEVATIONS.

9. PATCH AND REPAIR ANY / ALL WALL SURFACES AS REQUIRED TO PROVIDE SUITABLE

SUBSTRATE FOR FINISHES.

10. U.L. ASSEMBLIES DESCRIBED ARE FOR REFERENCE ONLY. THE GENERAL CONTRACTOR

SHALL COORDINATE AND VERIFY THE INSTALLATION OF THE DESCRIBED SYSTEM(S) .

11. REFER TO DOOR SCHEDULE FOR ADDITIONAL INFORMATION.

12. LOCATE THE HINGE SIDE JAMB OF DOORS 6" FROM ADJACENT PERPENDICULAR WALL,

UNLESS NOTED OTHERWISE.

13. PROVIDE ACOUSTICAL SEALANT AROUND WALL EDGES, TOP AND BOTTOM, AND

PENETRATIONS, AND INSTALL PUTTY PADS AROUND ELECTRICAL BOXES WHERE

PARTITION CONTAINS ACOUSTICAL INSULATION.

SYMBOL:

3 1/2" (3)

IF INFILL MATCH (E) WALL THICKNESS

A-3

A SERIES PARTITIONA

FIN. FLOOR, TYP.

UNDERSIDE OF DECK

OR BEAM ABOVE, TYP.

CONT. SEALANT

BOTH SIDES, TYP.

CONT. SEALANT

BOTH SIDES, TYP.

METAL STUD W/ 5/8"

IMPACT RESISTANT

GYP. BOARD EACH

SIDE

SLIP TRACK

SYMBOL: B-4

B SERIES PARTITIONB

FIN. FLOOR, TYP.

UNDERSIDE OF DECK

OR BEAM ABOVE, TYP.

CONT. SEALANT

BOTH SIDES, TYP.

CONT. SEALANT

BOTH SIDES, TYP.

4" X 8" X 16" CMU

BLOCK, TOOL JOINT

ROOM SIDE ONLY

IF INFILL, MATCH (E) WALL THICKNESS

4" (4)

G

(E) METAL FRAME FURRING

WALL

GYP. WALL RETURN

CAULK

(E) CMU WALL

(E) CMU WALL

CMU INFILL MATCH (E) WALL

(E) FURRING WALL

NEW FURRING WALL

(E) FURRED OUT WALL

5/8" GYP RETURN

(E) STOREFRONT WINDOW

CAULK

PROJECT NO.

CHECKED

DRAWN

DESIGNER

DATE ARCHIVE NO.

DRAWING SHEET NO.

SHEET OF

REVISION

PROJECT NAME

DATEREVISION / ISSUENO.

REVISION DATE

REVISION DATE

REVISION DATE

United States Department of Agriculture Forest Service

DRAWING TITLE

FIRE LAB AIR

QUALITY &

ELECTRONIC LAB

5/

/2

4:

:0

P

M

A3.2

05.23.19

C O

N S

T R

U C

T

IO

N D

O C

U M

E N

T S

ENLARGED PLANS

AREA C

18075.00

SM

LY

SM/LY

1/4" = 1'-0"9 ENLARGED AREA C PLAN NORTH

0'4' 2' 4' 8'

GENERAL NOTES

KEYNOTES

LEGEND

02-20 INFILL (E) DOOR OPENING TO MATCH (E) WALL

10-01 36" HORIZONTAL GRAB BAR

10-02 42" HORIZONTAL GRAB BAR

10-11 COMBINATION TRASH RECEPTACLE/PAPER

TOWEL DISPENSER

10-20 2-A RATED FIRE EXTINGUISHER W/ CABINET

10-21 4-A RATED FIRE EXTINGUISHER W/ CABINET

22-02 24" X 24" MOP SINK W/ STAINLESS STEEL

BACKSPLASH

A2.1

3" = 1'-0"13 FURRED WALL @ CMU

3" = 1'-0"14 INFILL DOOR @ CMU WALL

3" = 1'-0"15 STOREFRONT WINDOW JAM / SILL / HEAD

A3.2 A3.2 A3.2

G

H

J

RESTROOM /

SHWR

102 C

SERVER

ROOM

106 C

OPEN OFFICE

108 C

(E) MAIL

ROOM

109 C

(E) CORRIDOR

101 C

A5.1

A5.1

CT-1, CERAMIC TILING

SCRF-1, STATIC-CONTROL RESILIENT FLOORING

TC-1, TILE CARPETING

PROJECT NO.

CHECKED

DRAWN

DESIGNER

DATE ARCHIVE NO.

DRAWING SHEET NO.

SHEET OF

REVISION

PROJECT NAME

DATEREVISION / ISSUENO.

REVISION DATE

REVISION DATE

REVISION DATE

United States Department of Agriculture Forest Service

DRAWING TITLE

FIRE LAB AIR

QUALITY &

ELECTRONIC LAB

5/

/2

4:

:0

P

M

A3.2F

05.23.19

C O

N S

T R

U C

T

IO

N D

O C

U M

E N

T S

FLOOR FINISH

PLANS AREA C

18075.00

SM

LY

SM/LY

1/4" = 1'-0"10 ENLARGED AREA C FINISH FLOOR PLAN NORTH

0'4' 2' 4' 8'

KEYNOTES

LEGEND

LEVEL 1

100' - 0"

LEVEL 2

111' - 8"

12345678910111220

01-03 01-03 01-03 01-03 01-03 01-03 01-03 01-03 01-03 01-03 01-03

01-02 01-02 01-02 01-02 01-02 01-02 01-02 01-02 01-02

LEVEL 1

100' - 0"

LEVEL 2

111' - 8"

12345678910111220

01-02 01-02 01-02 01-02 01-02 01-02 01-02 01-02 01-02

01-0301-0301-0301-0301-0301-0301-0301-0301-0301-0301-03

LEVEL 1

100' - 0"

LEVEL 2

111' - 8"

FGHJ

A5.1

A5.1

E

F

G

H

J

A4.1

A5.1

A5.1

23-03

23-03

08-02

INDICATES BUILT ITEM TO BE REMOVED

MP-1 INSULATED METAL WALL PANELS IN STOREFRONT @ B-WING

MP-2 INSULATED METAL WALL PANELS @ C-WING

PROJECT NO.

CHECKED

DRAWN

DESIGNER

DATE ARCHIVE NO.

DRAWING SHEET NO.

SHEET OF

REVISION

PROJECT NAME

DATEREVISION / ISSUENO.

REVISION DATE

REVISION DATE

REVISION DATE

United States Department of Agriculture Forest Service

DRAWING TITLE

FIRE LAB AIR

QUALITY &

ELECTRONIC LAB

5/

/2

4:

:0

P

M

A4.1

05.23.19

C O

N S

T R

U C

T

IO

N D

O C

U M

E N

T S

EXTERIOR

ELEVATIONS / AREA

C ROOF PLAN

18075.00

SM

LY

SM/LY

1/8" = 1'-0"1 B-WING SOUTH ELEVATION

KEYNOTES

1/8" = 1'-0"5 B-WING SOUTH ELEVATION DEMO

01-02 ALT-2. B-WING WINDOW REPLACEMENT ENTIRE SOUTH ELEVATION 1ST FLOOR

01-03 ALT-3. B-WING WINDOW REPLACEMENT ENTIRE SOUTH ELEVATION 2ND FLOOR

08-02 (E) SKYLIGHT

23-03 MECH. ROOFTOP UNIT, SEE M3.3 FOR OPENINGS IN (E) DECKING SEE DETAIL

12/A7.1 FOR 4X4 STIFFENER BEAM @ OPENINGS

DEMOLITION LEGEND

1/8" = 1'-0"11 C-WING EAST ELEVATION

1/8" = 1'-0"13 C-WING ROOF PLAN

A4.1 EXTERIOR MATERIAL LEGEND

LEVEL 1

100' - 0"

LEVEL 2

111' - 8"

A5.1

A5.1

07-01

10-21

5'

TAPERED RIGID INSULATION

3/4" PLYWOOD SHEATHING

2X6 WOOD FRAMING @16" O.C.

2X JOIST HANGER

(E) 2X SKYLIGHT RISER

5/8 GYP.

2X BLOCKING

2X WOOD TRIM

SEALANT

EPDM MEMBRANE AS FLASHING

FASTENER

(E) GRAVEL BALLAST

RPF STRIP

(E) ROOFING MEMBRANE

(E) RIGID INSULATION

(E) BRICK WALL

(E) METAL FURRING WALL

SEALANT

INSULATED METAL PANEL

BASE TRIM

METAL WALL INFILL FRAMING

5/8" GWB

(E) BRICK WALL

(E) METAL FURRING WALL

BATT INSULATION FILL CAVITY

(E) ALUMINUM FLASHING

DRIP FLASHING

PAN FLASHING

HEAD TRIM

SEALANT

EXISTING WALL

NEW WALL

INSULATED METAL PANEL

METAL WALL INFILL FRAMING

5/8" GWB

(E) CONCRETE COLUMN

(E) METAL FURRING WALL

BASE TRIM

FLASHING

SEALANT

SEALANT

1/4" / 1'

1/ 4"

1'

1/4" / 1'

1/ 4"

1'

PROJECT NO.

CHECKED

DRAWN

DESIGNER

DATE ARCHIVE NO.

DRAWING SHEET NO.

SHEET OF

REVISION

PROJECT NAME

DATEREVISION / ISSUENO.

REVISION DATE

REVISION DATE

REVISION DATE

United States Department of Agriculture Forest Service

DRAWING TITLE

FIRE LAB AIR

QUALITY &

ELECTRONIC LAB

5/

/2

4:

:0

P

M

A5.1

05.23.19

C O

N S

T R

U C

T

IO

N D

O C

U M

E N

T S

SECTIONS AREA C

18075.00

Checker

Author

Designer

1/4" = 1'-0"2 C-WING SECTION

KEYNOTES

07-01 INSULATED METAL WALL PANELS

10-21 4-A RATED FIRE EXTINGUISHER W/ CABINET

1 1/2" = 1'-0"6 SKYLIGHT INFILL

3" = 1'-0"7 STOREFRONT INFILL HEAD / SILL @ SERVER ROOM

LEGEND

3" = 1'-0"10 STOREFRONT INFILL JAMB @ SERVER ROOM

1/2" = 1'-0"11 SKYLIGHT INFILL PLAN

A3.2

A5.1 A5.1

A3.2 A4.1

09-01

02-05

12-08

1' - 6" 3' - 0" 3' - 0" 1' - 6"

2'

0"

1'

1'

2'

2' - 8" 1' - 6" 3' - 0" 3' - 0" 1' - 6"

09-02

D30W

342218

E41W

342236

G00W

342236

D30W

342218

W25W

361218L

W25W

361236

W25W

241236

W25W

361218L

FUTURE

FUME

HOOD

(E) FUME HOOD

09-02

2' - 0"2' - 0"2' - 0"2' - 0"2' - 0"

7'

S25W

842224L

S25W

842224L

S25W

842224L

S25W

842224L

S25W

842224L

10-20

5'

12-08

2'

0"

1'

3'

2' - 5" 2' - 6" 2' - 0" 1' - 6" 2' - 0" 3' -…