1282FT18R0009AME0001.pdf
PDF 4 MB Posted
- Attached to
- Fort Collins Main Building Reroofing Federal contract opportunity
- Solicitation number
- 1282FT18R0009
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| 1282FT18R0009AME0004.pdf | ||
| 1282FT18R0009AME0003.pdf | ||
| 1282FT18R0009AME0002.pdf | ||
| Solicitation_1282FT18R0009.doc.pdf | ||
| Attachment_2_-_Drawings.pdf | ||
| Attachment_1_-_Specifications.pdf | ||
| Attachment_3_-_Wage_Determination.pdf |
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
(x)
1282FT18R0009
x x
1 copies of the amendment; (b) By acknowledging receipt of this amendment on each copy of the offer submitted ; or (c) By separate letter or telegram which includes a reference to the solicitation and amendment numbers. FAILURE OF YOUR ACKNOWLEDGEMENT TO BE RECEIVED AT
THE PLACE DESIGNATED FOR THE RECEIPT OF OFFERS PRIOR TO THE HOUR AND DATE SPECIFIED MAY RESULT IN REJECTION OF YOUR OFFER. If by virtue of this amendment you desire to change an offer already submitted , such change may be made by telegram or letter, provided each telegram or letter makes reference to the solicitation and this amendment, and is received prior to the opening hour and date specified.
x
82FT
FORT COLLINS CO 80526
240 W PROSPECT STREET
ROCKY MOUNTAIN RESEARCH STATION
USDA FOREST SERVICE
06/27/20180001
13. THIS ITEM ONLY APPLIES TO MODIFICATION OF CONTRACTS/ORDERS. IT MODIFIES THE CONTRACT/ORDER NO. AS DESCRIBED IN ITEM 14.
12. ACCOUNTING AND APPROPRIATION DATA (If required) is not extended.is extended, Items 8 and 15, and returning
Offers must acknowledge receipt of this amendment prior to the hour and date specified in the solicitation or as amended , by one of the following methods: (a) By completing
The above numbered solicitation is amended as set forth in Item 14. The hour and date specified for receipt of Offers
11. THIS ITEM ONLY APPLIES TO AMENDMENTS OF SOLICITATIONS
FACILITY CODE CODE
10B. DATED (SEE ITEM 13)
10A. MODIFICATION OF CONTRACT/ORDER NO.
9B. DATED (SEE ITEM 11)
9A. AMENDMENT OF SOLICITATION NO.
CODE
8. NAME AND ADDRESS OF CONTRACTOR (No., street, county, State and ZIP Code)
7. ADMINISTERED BY (If other than Item 6)CODE 6. ISSUED BY
PAGE OF PAGES
4. REQUISITION/PURCHASE REQ. NO.3. EFFECTIVE DATE2. AMENDMENT/MODIFICATION NO. 5. PROJECT NO. (If applicable)
1. CONTRACT ID CODE
AMENDMENT OF SOLICITATION/MODIFICATION OF CONTRACT
06/27/2018
CHECK ONE A. THIS CHANGE ORDER IS ISSUED PURSUANT TO: (Specify authority) THE CHANGES SET FORTH IN ITEM 14 ARE MADE IN THE CONTRACT
B. THE ABOVE NUMBERED CONTRACT/ORDER IS MODIFIED TO REFLECT THE ADMINISTRATIVE CHANGES (such as changes in paying office, C. THIS SUPPLEMENTAL AGREEMENT IS ENTERED INTO PURSUANT TO AUTHORITY OF:
D. OTHER (Specify type of modification and authority) appropriation date, etc.) SET FORTH IN ITEM 14, PURSUANT TO THE AUTHORITY OF FAR 43.103(b).
E. IMPORTANT: Contractor is not, is required to sign this document and return __________________ copies to the issuing office.
ORDER NO. IN ITEM 10A.
14. DESCRIPTION OF AMENDMENT/MODIFICATION (Organized by UCF section headings, including solicitation/contract subject matter where feasible.)
Fort Collins Main Building Reroofing
The purpose of Amendment 0001 is as follows:
Provide the Asbestos Inspection Report, the Staging Area document, Site Visit Sign in
Sheet, and Questions and Answers from the Pre-Bid Meeting.
Period of Performance: 08/06/2018 to 12/04/2018
16A. NAME AND TITLE OF CONTRACTING OFFICER (Type or print)15A. NAME AND TITLE OF SIGNER (Type or print)
15C. DATE SIGNED 16B. UNITED STATES OF AMERICA 15B. CONTRACTOR/OFFEROR 16C. DATE SIGNED
(Signature of person authorized to sign) (Signature of Contracting Officer)
ANTHONY O. SALAS
STANDARD FORM 30 (REV. 10-83)
Prescribed by GSA
FAR (48 CFR) 53.243
NSN 7540-01-152-8070
Previous edition unusable
Except as provided herein, all terms and conditions of the document referenced in Item 9 A or 10A, as heretofore changed, remains unchanged and in full force and effect .
ASBESTOS INSPECTION
FOR USDA ROCKY MOUNTAIN RESEARCH STATION
240 WEST PROSPECT ROAD, FORT COLLINS
COLORADO
October 20, 2010
Prepared for:
USDA Rocky Mountain Research Station 240 West Prospect Road Fort Collins, CO 80526
Prepared by:
Greg Estes Project Manager/Inspector
Reviewed by:
Jim Dennison Certified Industrial Hygienist
Submitted by Century Environmental Hygiene, LLC
199 South Shields Street Fort Collins, Colorado 80521
(970) 266-8000
CEH Project Number: 2944.10
TABLE OF CONTENTS
ACRONYMS AND ABBREVIATIONS………………………………………………………………… .. 1
1 INTRODUCTION
1.1 Background
1.2 Asbestos Regulatory Compliance - EPA, NESHAP, and State Programs
2 METHODOLOGY / PURPOSE AND SCOPE OF WORK
2.1 Asbestos Inspection ..................................................................................................................................... 3-6
3 FINDINGS
3.1 Asbestos Inspection ..................................................................................................................................... 6-8
4 RECOMMENDATIONS
4.1 Asbestos Inspection
5 LIMITATIONS ......................................................................................................................................... 8-9
6 ASBESTOS REFERENCES
7 GLOSSARY ............................................................................................................................................. 9-10
LIST OF TABLES
Table 1 Bulk Sampling Strategy……………………………………………………………………………………..5
Table 2 Asbestos-Containing Materials ................................................................................................................. 6-7
LIST OF APPENDICES
Appendix A Asbestos Containing Material Data Tables (ACM Data Tables) …………..12-25
Appendix B Laboratory Reports and Chain of Custody ……………………………….27-51
Appendix C Photographs of Homogeneous Materials ……………………………...53-64
Appendix D Maps of Sample Locations and ACM ……………………………...66-70
Appendix E Consultant Qualifications and Credentials ………………………………...72
ACRONYMS AND ABBREVIATIONS
ACM Asbestos-Containing Materials ACBM Asbestos-Containing Building Materials AHERA USEPA Asbestos Emergency Hazard Response Act CAA Clean Air Act CEH Century Environmental Hygiene, LLC CERCLA Comprehensive Environmental Response, Compensation, and Liability Act CWA Clean Water Act D/R Demolition and/or Renovation EPCRA Emergency Planning and Community Right-to-Know Act HVAC Heating Ventilation and Air Conditioning NESHAPs National Emission Standards for Hazardous Air Pollutants NVLAP National Volunteer Laboratory Accreditation Program PACM Presumed Asbestos-containing Material PEL Personal Exposure Limit PLM Polarized Light Microscopy O&M Asbestos Operations and Maintenance OSHA Occupational Safety and Health Administration RACM Regulated Asbestos-Containing Material RCRA Resource Conservation and Recovery Act SAFR Spray-Applied Fire Retardant TSCA Toxic Substances Control Act TSI Thermal System Insulation USEPA United States Environmental Protection Agency VAT Asbestos Containing Vinyl Tile
USDA RMRS Report Date 10.20.10
ASBESTOS INSPECTION FOR USDA ROCKY MOUNTAIN
RESEARCH STATION
1 INTRODUCTION
1.1 Background
This report provides an overview of the asbestos building inspection performed by Century Environmental Hygiene, LLC (CEH) of the USDA Rocky Mountain Research Station located at 240 West Prospect Road, Fort Collins, Colorado.
The scope of the investigation included inspection for Asbestos-Containing Building Materials (ACBM). The inspection was performed in a non-destructive manner at the request of the client, thus this inspection should not be construed as a demolition/renovation specific asbestos inspection. Prior to demolition/renovation, a subsequent inspection is required using destructive investigation (to inspect behind enclosed walls, above enclosed ceilings, etc) to detect any hidden or concealed conditions.
The building is a concrete and steel structure constructed in the late 1960’s and consists of approximately 42,000 square feet.
The sampling and inspection process was conducted in accordance with standards of the Emission Standards for Hazardous Air Pollutants (NESHAP) regulations as implemented by the Colorado Department of Public Health and Environment (CDPHE), OSHA Construction and General Industry Standards for asbestos, and other applicable industry standards. Asbestos inspection activities were conducted by Colorado accredited personnel between October 4 and October 8, 2010. The inspection was conducted in preparation for renovation of the building.
1.2 Asbestos Regulatory Compliance - EPA, NESHAP, and State Programs
ACBM identified in this report is subject to the USEPA NESHAP Regulations for Asbestos (40 CFR Part 61) as implemented by the Colorado Department of Public Health and Environment (CDPHE) and OSHA Standards for Asbestos (29 CFR Part 1910.1001). Materials containing 1% or less asbestos may be subject to OSHA regulations if air concentrations are at or above the personal exposure limit (PEL) of 0.1 fibers per cubic centimeter (f/cc) or the excursion limit of
1.0 f/cc. All friable and certain non-friable materials that will be rendered friable during renovation activities are required by regulation to be removed prior to renovation.
2 METHODOLOGY / PURPOSE AND SCOPE OF WORK
2.1 Asbestos Inspection
The sampling and asbestos non-destructive investigation process was conducted in accordance with applicable industry standards (including EPA, NESHAP and OSHA asbestos regulations).
The scope of the asbestos inspection was to identify asbestos-containing building materials (ACBM) and included the following steps:
Review of site drawings and records.
Visual inspection of all accessible areas of the building to identify suspect materials.
Visual inspection of all areas of suspect homogeneous and non-homogeneous ACBM.
Determination of friability by touching all suspect ACBM.
Development and implementation of a sampling plan for each material based on the homogeneous material type, friability, accessibility and material locations. Homogeneous and non-homogeneous material samples were submitted for laboratory analysis by Polarized Light Microscopy (PLM).
The following building systems were inspected to identify suspected homogeneous materials.
Ceiling Systems Thermal/mechanical Systems Flooring Systems Wall/partition Systems Structural Systems Electrical Systems Miscellaneous Systems
A homogeneous area (material) is defined as an area containing a material that appears similar throughout with regard to color, texture, and date of application, if known.
Individual systems that were inspected, but not suspected to contain asbestos, are not included in this report. Such systems include concrete, carpet, fiberglass, plastic, rubberized and wood products.
Each type of suspect building material (homogeneous) size, thickness, substrate, material friability, location, and quantity were recorded. Material information was recorded on a room-by-room asbestos inspection form. The homogeneous material was classified into one of three available types of homogeneous material descriptions.
Surfacing Material refers to a wide range of trowel or spray-applied materials typically used for acoustical or fire retarding purposes. Examples include spray-applied fire retardant and acoustical texture ceilings.
Thermal System Insulation (TSI) refers to insulation that is applied to heating or mechanical system components. Examples include pipe, tank and boiler insulation.
Miscellaneous Materials refers to all other materials that do not fall into one of the above categories. Examples include floor tile, adhesives, and ceiling tiles.
Once the type of homogeneous material was determined, it was then classified as friable or not.
The USEPA distinguishes between friable and non-friable forms of ACBM. Friable materials, when dry, can be crumbled or reduced to powder by hand pressure, whereas non-friable materials cannot. Friable materials are more likely to be released into the air, especially during demolition of the building. Therefore, the distinction between friable and non-friable homogeneous material is important.
EPA has identified two categories of materials, “Regulated” and “Non-regulated” ACM, for the purpose of identifying materials that can or cannot remain within a building during demolition.
Regulated asbestos-containing materials (RACMs) are defined as friable materials and non-friable materials that have a high probability of becoming friable during demolition activities.
RACMs are categorized as all friable ACBM, Category I non-friable ACBM that may become friable (subject to sanding, grinding, cutting or abrading during the demolition process), or Category II non-friable ACM that has a probability of becoming crumbled, pulverized, or reduced to a powder by the forces expected to act on the material in the course of normal demolition operations (that are performed in accordance with EPA NESHAPS demolition guidance). Non-regulated asbestos-containing materials (non-RACM) are those non-friable materials likely remain non-friable during normal demolition operations. Non-RACM is categorized as either Category I non-friable ACBM that will not be subject to sanding, grinding, cutting or abrading during the demolition process, or Category II non-friable ACM that has a low probability of becoming crumbled, pulverized, or reduced to a powder by the forces expected to act on the material in the course of normal demolition operations. EPA regulations require proper removal and disposal of all RACMs prior to demolition operations. EPA regulations allow non-RACMs to remain in place during demolition (provided demolition methods do not render the material friable) and allow these materials to be disposed as normal demolition debris.
However, EPA also requires the removal and proper disposal of certain non-RACMs prior to implementation of demolition activities that could potentially disturb these materials.
Samples were numbered based on the following format: “062810FTC01-01” The first six digits identify the date the sample was taken. The next four/five digits identify the homogeneous material. The final two digits are the specific sample number within the group of samples for that homogenous material.
The following Bulk Sampling protocol for friable and Category I and II materials was used to determine the number of samples to be collected.
Table 1 Bulk Sampling Strategy Material Homogeneous
Area Units Minimum Number of Samples Friable Surfacing Less than 1000
1000 to 5000 More than 5000
SF
SF
SF
Non-friable Surfacing - - - SF 3 Friable and Non-friable Thermal System Insulation
- - - LF / SF / EA 3
Friable Miscellaneous Materials - - - LF / SF / EA 3 Non-friable Miscellaneous Materials - - - LF / SF / EA 3
* One sample was collected for limited quantity replacement or patch (salient) materials located in a single room/functional space. Two samples were collected for limited quantity materials located in two rooms/functional spaces. Three or more samples were collected where materials were in three or more rooms, or where significant quantities were identified.
CEH collected bulk samples of the homogenous materials in a random and representative manner as determined by each inspector and following applicable guidelines. Samples were collected by taking a composite core sample that included all layers within the suspect material.
Samples from soft friable materials were obtained by removing a small portion using wetting techniques. All samples were placed in sealed, labeled containers, and the sample descriptions and locations were recorded. At the time of collection, samples were labeled with an appropriate and unique number. This number (along with other information such as sample location, color, texture, and condition) was recorded in the asbestos inspection form.
The bulk samples were submitted for progressive analysis (positive stop) to DCM Science Laboratory Inc., a National Volunteer Laboratory Accreditation Program (NVLAP) accredited laboratory. Under progressive analysis, once a positive result is obtained within a sample set, all subsequent samples within that set are not analyzed. In some cases, based on professional judgment, progressive analysis may not have been performed.
Analysis of the bulk samples was performed using Polarized Light Microscopy (PLM) using procedures developed by McCrone Research Institute, and in compliance with the guidelines established by the Environmental Protection Agency (USEPA-600/M4-82-020, Dec. 1982) to determine asbestos type and content. The PLM samples are reported as percent asbestos by weight. Percent asbestos for separate layers and total for the sample are delineated in the laboratory report. Unused portions of samples are archived for six months unless the client requests special handling.
As of November 20, 1990, the USEPA NESHAP requires that samples with less than 10 percent asbestos be analyzed by the point-count procedure, or must be assumed positive for asbestos.
Samples containing 1 percent or less asbestos were analyzed under the point-counting method
(to avoid false negatives, or inaccurately classifying asbestos-containing material as non-asbestos containing material).
The inspector delivered the samples along with a completed chain of custody document to the laboratory. The laboratory then arranged the samples in numerical order. If a discrepancy between the samples exists, this is noted and initialed on the log sheet. The laboratory signed a copy of the sample log to acknowledge receipt. The inspector retained the signed copy for evidentiary purposes. Further, the laboratory assigned a laboratory number to each sample received. The laboratory labeled both the analytical report and the sample container with this laboratory number for cross-reference purposes.
3 FINDINGS
3.1 Asbestos Inspection
The inspection identified 47 types of suspected asbestos-containing homogeneous building materials. A total of 119 bulk samples were collected during the inspection. A material is considered to be asbestos-containing building material (ACBM) if the asbestos content is greater than 1% asbestos. 11 ACBMs were identified. 1 material was identified as composite and 2 trace-containing materials were identified, which are not subject to EPA regulations, but may be subject to OSHA regulations.
The ACM Data Table in Appendix B summarizes the ACMs identified in the building. The EPA regulations require proper removal and disposal of Friable and Category II non-friable materials prior to building demolition or renovation activities that would disturb these materials.
The following materials were identified to contain greater than one percent asbestos:
Material Description Material Type Friability Percentage and Type of Asbestos
Approximate Quantity*
DS02 –White duct sealant on foil insulation
Miscellaneous Category II Non-friable
5% Chrysotile NQ
FTC01 – 9” X 9” white floor tile with green streaks associated with black mastic
Miscellaneous Category I Non-friable
Floor tile 12% Chrysotile Black mastic 3% Chrysotile
21,110 SF
FTC02 – 12” X 12” gray floor tile with gray and white streaks associated with black mastic
Miscellaneous Category I Non-friable
Floor tile ND Black mastic 7% Chrysotile
198 SF
FTC03 – 12” X 12” white floor tile with gray streaks associated with black mastic
Miscellaneous Category I Non-friable
Floor tile ND Black mastic 8% Chrysotile
480SF
Material Description Material Type Friability Percentage and Type of Asbestos
Approximate Quantity*
MA03 – Yellow carpet adhesive and black mastic
Miscellaneous Category II Non-friable
Yellow carpet adhesive ND Black mastic 7% Chrysotile
6,761 SF
PF01 – Mudded pipe fittings and hangers
Thermal Friable 4% Chrysotile 4% Amosite
664 EA**
RF01 – 1/8” rubber membrane, 3” foam, 1 layer of felt and black tar associated with roof field area
Miscellaneous Category I Non-friable
Black fibrous tar 63% Chrysotile
NQ
RS01 – Brown tar associated with first floor AC hood
Miscellaneous Category II Non-friable
Brown tar 25% Chrysotile
NQ
RS02 – Brown tar associated with brick chimney stack
Miscellaneous Category II Non-friable
Brown tar 25% Chrysotile
NQ
TI01 – Fibrous plaster with canvas wrap
Thermal Friable 79% Chrysotile 100 SF
TR01 – Transite lab counter tops
Miscellaneous Category II Non-friable
12% Chrysotile 22 EA
SF = Square Feet EA = Each ND = No Asbestos Detected NQ = Not Quantified
** Mudded pipe fittings may exist in pipe chases, above hard ceilings, and restroom walls and were not included in the quantities due to the nature of the asbestos investigation was non-destructive
* The quantities identified above are approximate and are for estimating purposes only
The category II non-friable materials will likely need to be abated if the renovation planned will impact these materials. Some Category I materials may not need to be abated (roofing materials) while other may need to be abated (floor tile).
The following material was identified to contain < 1% asbestos through composite sampling:
(CDW02) – Drywall, ½”, white, composite of drywall and joint compound fmcarthur Highlight
The following materials were identified to contain trace amounts of asbestos:
(BS01) – White block sealant associated with CMU walls (CTA01) – Brown adhesive associated with 1’ X 2’ ceiling tile with stretched fissure and small worm hole
Materials containing 1% or less asbestos may be subject to OSHA regulations if air concentrations are at or above the personal exposure limit (PEL) of 0.1 f/cc or the excursion limit of 1.0 f/cc.
Refer to Appendix A for sampling and analytical information associated with the asbestos inspection.
4 RECOMMENDATIONS
4.1 Asbestos Inspection
All friable and Category II non-friable materials are required by regulation to be removed prior to renovation activities that will impact these materials.
The types and locations of the non-friable Category I materials and subsequent regulatory requirements must be disclosed to the renovation/demolition contractor and/or salvage contractor to avoid accidental disturbance and to ensure contractor compliance with applicable regulations (to ensure proper worker protection and material disposal).
5 LIMITATIONS
CEH performed asbestos investigation services in a manner consistent with the level of care and expertise exercised by members of the asbestos inspection and assessment profession. CEH does not imply or guarantee that every potential asbestos containing material on or in the building has been identified or sampled. Historically, asbestos has been added as a component to over 3,000 materials and products produced in the United States. The inspection was intended to identify those accessible materials that were reasonably suspect and that were most likely to contain asbestos in quantities subject to regulation, based upon existing industry and regulatory standards.
The inspection was intended to identify those accessible materials that were reasonably suspect and that could be identified through destructive investigation that were most likely to contain asbestos in quantities subject to regulation, based on existing industry and regulatory standards.
Often materials cannot be assessed (sampled) due to physical constraints encountered (locked rooms, enclosed areas, etc.).
No survey can completely eliminate the uncertainty regarding the presence of asbestos-containing materials. The level of diligence and investigative procedures utilized are intended to reduce, but not eliminate, potential uncertainty regarding the presence of these materials. The procedures used for this survey attempted to establish a balance between the competing goals of inspection cost and time. The determinations of this report should not be construed as a guarantee that all such materials present in the subject property has been identified in the report.
6 ASBESTOS REFERENCES
United States Environmental Protection Agency, National Emission Standards for Hazardous Air Pollutants (NESHAP) 40 CFR 61.140-157.
United States Environmental Protection Agency, Asbestos-Containing Materials in Schools;
Final Rule and Notice (Asbestos Hazard Emergency Response Act - AHERA) 40 CFR 763.80-99, 1990.
United States Environmental Protection Agency, Simplified Sampling Scheme for Surfacing Materials (“Pink Book”) EPA publication #560/5-85-030a, Washington DC, 1985.
Occupational Safety and Health Administration, Asbestos Regulations for the Construction Industry 29 CFR 1926.1101, Washington DC, 1994.
Occupational Safety and Health Administration, Asbestos Regulations for the General Industry 29 CFR 1910.1001, Washington DC, 1994.
7 GLOSSARY
ASBESTOS - A generic name given to a number of naturally occurring silicates that have a unique crystalline structure. They are incombustible in air and separable into fibers. Asbestos includes the asbestiform varieties of Chrysotile, Crocidolite, Amosite, Anthophyllite, Actinolite, and Tremolite.
ACBM - Asbestos-Containing Building Material. Any material with one percent (1%) or more asbestos content. A term that encompasses surfacing, thermal system, and miscellaneous asbestos-containing material in or on interior/exterior parts of a building.
BULK SAMPLE - A piece of suspected asbestos-containing building material.
FIBER RELEASE - The process by which dust is given off from asbestos materials and becomes airborne.
FRIABLE - A material which can be crumbled, pulverized, or reduced to powder when dry, by moderate hand pressure.
FUNCTIONAL AREA - Specially distinct units within a building such as a room, a group of rooms, or a homogeneous area - this includes crawl spaces and areas above a drop ceiling.
HVAC - Heating, Ventilating, and Air Conditioning Systems. The system of pipes, ducts, and equipment (air conditioners, chillers, heaters, boilers, pumps, fans) used to heat, cool, move, and filter air in a building.
HOMOGENEOUS AREA - An area which appears similar throughout in terms of color, texture, and date of material application.
INACCESSIBLE AREA - Inaccessible areas are those areas which cannot be inspected due to physical barriers. Buildings may contain areas that are intrinsically inaccessible. These include gaps and spaces in walls, areas above fixed ceilings and below floors, and enclosed boiler breechings and ducts. Some buildings contain other inaccessible areas, such as very small pipe tunnels, sealed crawl spaces, unsafe attics, encased boilers, etc.
NON-FRIABLE - A material which cannot be crumbled or pulverized by hand pressure.
PACBM - Presumed Asbestos-Containing Building Material
PIPE JOINT - The elbow, valve, connector, reduction or pipe hanger.
PLENUM - A space designed to transport air in a building. They are commonly found below ground level and in the space between a dropped ceiling and the floor above it.
PLM - Polarized Light Microscopy. An accepted method for analyzing bulk ACBM samples.
USEPA (EPA) - United States Environmental Protection Agency. The federal agency which governs environmental problems. In the case of ACBM in buildings, the USEPA deals with regulations and their guidelines for application, renovation, removal, and disposal of ACBM in building structures.
APPENDIX A
Asbestos Containing Material Data Tables (ACM Data Tables) This section provides information on the homogeneous material, locations of homogeneous materials and collection of bulk samples and the subsequent laboratory analysis during the inspection.
Asbestos Sampling Data Table USDA FS Rocky Mountain Research Station
Project # 2944.10
Material Code Homogenous Material Description Material Location(s) Sample # Sample Location (Room#) Result
BBA01
Brown baseboard adhesive assoc.
w/ 6" light brown baseboards
178 all walls, 179 all walls, 180 all walls, 181 all, 182 all, 183 all, 184 all, 185 all, SW1 N/S/E, Dock all walls, 187 all, 190A all, 191 all, 138 all, NHW1 E/W, 173 all, 172 all, 171 all, 174 all, 175 all, 170 all, NHW3 N/S, 198 all, 189, NHW2 E/W, 169 all, 167 all, 166A, 166B, 197 all, 196 all, 168, CHW2 all, CHW1 S (carpet over), 139, 137, 140, 143, 136, 135, 134, 133, 145, 165A, 164, 165B, 165D, 132, 131, 130, 149, 129, 128, 123, 127, 126, 125, 124, 150, 120, 119, 118, 117, 116, 115, 114, 113, 151, 153, 154, 112, 111, 155A, 155B, 156, 157, 158A, CHW4, 110, 108, CHW4, 106, 105, 104, CHW3 lobby, Lobby, 2SHW, 206, 207, 208, 209, 210, 213, 214, 215, 217, 218, 219, 221, 222, 223, 224, 225, 2WHW, 239, 239A, 238, 236, 235, 234, 232, 107
100110BBA0
1‐01
Room 178 E wall, 3" from N ND
BBA01
Brown baseboard adhesive assoc.
w/ 6" light brown baseboards
178 all walls, 179 all walls, 180 all walls, 181 all, 182 all, 183 all, 184 all, 185 all, SW1 N/S/E, Dock all walls, 187 all, 190A all, 191 all, 138 all, NHW1 E/W, 173 all, 172 all, 171 all, 174 all, 175 all, 170 all, NHW3 N/S, 198 all, 189, NHW2 E/W, 169 all, 167 all, 166A, 166B, 197 all, 196 all, 168, CHW2 all, CHW1 S (carpet over), 139, 137, 140, 143, 136, 135, 134, 133, 145, 165A, 164, 165B, 165D, 132, 131, 130, 149, 129, 128, 123, 127, 126, 125, 124, 150, 120, 119, 118, 117, 116, 115, 114, 113, 151, 153, 154, 112, 111, 155A, 155B, 156, 157, 158A, CHW4, 110, 108, CHW4, 106, 105, 104, CHW3 lobby, Lobby, 2SHW, 206, 207, 208, 209, 210, 213, 214, 215, 217, 218, 219, 221, 222, 223, 224, 225, 2WHW, 239, 239A, 238, 236, 235, 234, 232, 107
100110BBA0
1‐02 CNWZ, south wall, behind
164 door ND
BBA01
Brown baseboard adhesive assoc.
w/ 6" light brown baseboards
178 all walls, 179 all walls, 180 all walls, 181 all, 182 all, 183 all, 184 all, 185 all, SW1 N/S/E, Dock all walls, 187 all, 190A all, 191 all, 138 all, NHW1 E/W, 173 all, 172 all, 171 all, 174 all, 175 all, 170 all, NHW3 N/S, 198 all, 189, NHW2 E/W, 169 all, 167 all, 166A, 166B, 197 all, 196 all, 168, CHW2 all, CHW1 S (carpet over), 139, 137, 140, 143, 136, 135, 134, 133, 145, 165A, 164, 165B, 165D, 132, 131, 130, 149, 129, 128, 123, 127, 126, 125, 124, 150, 120, 119, 118, 117, 116, 115, 114, 113, 151, 153, 154, 112, 111, 155A, 155B, 156, 157, 158A, CHW4, 110, 108, CHW4, 106, 105, 104, CHW3 lobby, Lobby, 2SHW, 206, 207, 208, 209, 210, 213, 214, 215, 217, 218, 219, 221, 222, 223, 224, 225, 2WHW, 239, 239A, 238, 236, 235, 234, 232, 107
100110BBA0
1‐03
174 W wall, N of door ND
BBA02
Cream baseboard adhesive associated w/ 6" vinyl baseboard
SEC1 all, STOR1, 190B, NHW1 E/W, NHW3 N/S, NHW2, 196 all, CHW1, 126A, EHW1, 120A, 114, EHW2, CHW4, 110, 109, 106, 105, 104, 2SHW, 206, 207, 208, 209, 2EHW, 211, 212, 213, 215, 2NHW, 220, 225, 2WHW, 239, 239A, 238, 235, 232
100410BBA0
2‐01 SEC1 E wall, 1' from N ND
BBA02
Cream baseboard adhesive associated w/ 6" vinyl baseboard
SEC1 all, STOR1, 190B, NHW1 E/W, NHW3 N/S, NHW2, 196 all, CHW1, 126A, EHW1, 120A, 114, EHW2, CHW4, 110, 109, 106, 105, 104, 2SHW, 206, 207, 208, 209, 2EHW, 211, 212, 213, 215, 2NHW, 220, 225, 2WHW, 239, 239A, 238, 235, 232
100810BBA0
2‐02 2nd floor HW NE corner, N wall, 1' from E ND
BBA02
Cream baseboard adhesive associated w/ 6" vinyl baseboard
SEC1 all, STOR1, 190B, NHW1 E/W, NHW3 N/S, NHW2, 196 all, CHW1, 126A, EHW1, 120A, 114, EHW2, CHW4, 110, 109, 106, 105, 104, 2SHW, 206, 207, 208, 209, 2EHW, 211, 212, 213, 215, 2NHW, 220, 225, 2WHW, 239, 239A, 238, 235, 232
100810BBA0
2‐03 232 N wall, E of doorway ND
Project # 2944.10
Material Code Homogenous Material Description Material Location(s) Sample # Sample Location (Room#) Result
BBA03 Yellow/tan adhesive Room 141, 144, 146, 157, 109, 202, 203, 204, 205, 216, 218, 2NHW, 219, 221, 234
100510BBA0
3‐01 Room 141 S wall, 4' from W ND
BBA03 Yellow/tan adhesive Room 141, 144, 146, 157, 109, 202, 203, 204, 205, 216, 218, 2NHW, 219, 221, 234
100810BBA0
3‐02 Room 205 E wall, behind door ND
BBA03 Yellow/tan adhesive Room 141, 144, 146, 157, 109, 202, 203, 204, 205, 216, 218, 2NHW, 219, 221, 234
100810BBA0
3‐03 Room 234, W wall center ND
BS01
White block sealant associated w/ block walls 119, 198 all, 189, 139 all walls, 141 all, 140, 143 all, 144 all, 145 N/S, 151 all, 153 all, 154 all, 155A all, 155B, 156 all, 157 all, 238 E, 238 N/E/S, B1‐EN
100410BS01‐
Room 191, E doorway, below light switch 0.25% Chry
BS01
White block sealant associated w/ block walls 119, 198 all, 189, 139 all walls, 141 all, 140, 143 all, 144 all, 145 N/S, 151 all, 153 all, 154 all, 155A all, 155B, 156 all, 157 all, 238 E, 238 N/E/S, B1‐EN
100810BS01‐
Room 236, S wall center near floor ND
BS01
White block sealant associated w/ block walls 119, 198 all, 189, 139 all walls, 141 all, 140, 143 all, 144 all, 145 N/S, 151 all, 153 all, 154 all, 155A all, 155B, 156 all, 157 all, 238 E, 238 N/E/S, B1‐EN
100810BS01‐
Room 238, S wall centter near floor ND
BS01
White block sealant associated w/ block walls 119, 198 all, 189, 139 all walls, 141 all, 140, 143 all, 144 all, 145 N/S, 151 all, 153 all, 154 all, 155A all, 155B, 156 all, 157 all, 238 E, 238 N/E/S, B1‐EN
100810BS01‐
Room 156, E wall, 4' from N
2' high 0.25% Chry
BS01
White block sealant associated w/ block walls 119, 198 all, 189, 139 all walls, 141 all, 140, 143 all, 144 all, 145 N/S, 151 all, 153 all, 154 all, 155A all, 155B, 156 all, 157 all, 238 E, 238 N/E/S, B1‐EN
100810BS01‐
Room 151, S wall center above grid <0.25% Chry
BS01
White block sealant associated w/ block walls 119, 198 all, 189, 139 all walls, 141 all, 140, 143 all, 144 all, 145 N/S, 151 all, 153 all, 154 all, 155A all, 155B, 156 all, 157 all, 238 E, 238 N/E/S, B1‐EN
100810BS01‐
Room 191, 5' from E on S wall by entry 0.75% Chry
BS01
White block sealant associated w/ block walls 119, 198 all, 189, 139 all walls, 141 all, 140, 143 all, 144 all, 145 N/S, 151 all, 153 all, 154 all, 155A all, 155B, 156 all, 157 all, 238 E, 238 N/E/S, B1‐EN
100810BS01‐
07 B1 E wall S side of door ND
CDW01
1/2" pink DW w/ brown paper assoc. w/ joint compound
178 N, 179 S/N, 180 S, 181 S, 182 N/S, 183 N/S, 185 N, SEC1, STOR1, DOCK S, 187S, 190B S, 138 N, 173 N/S 172 N/S, 171 N/S, 174 N/S, 175 N, 170 N/S, 169 N/S, 167
N/S, 166A N, 168 N/S, 137E, 135 E/W, 134 E/W, 133 E/W, 165D, 132 E/W, 131 E/W, 130 E/W, 129 E/W, 128 E/W, 123 E, 127E/W, 126 E/W, 125 E/W, 124 W/E, 120 E/W, 119 E/W, 118 E/W, 117 E/W, 116 E/W, 115 E/W, 114 E/W, 113 E/W, 112 E/W, 111 E/W, 110 E/W, 109 E/W, 108 E/W 106 E/W 105 E/W/N, 104 all, LC E, Lobby W, 107
E/W
100410CDW
01‐01 SEC1, E wall, 1' from N ND
CDW01
1/2" pink DW w/ brown paper assoc. w/ joint compound
178 N, 179 S/N, 180 S, 181 S, 182 N/S, 183 N/S, 185 N, SEC1, STOR1, DOCK S, 187S, 190B S, 138 N, 173 N/S 172 N/S, 171 N/S, 174 N/S, 175 N, 170 N/S, 169 N/S, 167
N/S, 166A N, 168 N/S, 137E, 135 E/W, 134 E/W, 133 E/W, 165D, 132 E/W, 131 E/W, 130 E/W, 129 E/W, 128 E/W, 123 E, 127E/W, 126 E/W, 125 E/W, 124 W/E, 120 E/W, 119 E/W, 118 E/W, 117 E/W, 116 E/W, 115 E/W, 114 E/W, 113 E/W, 112 E/W, 111 E/W, 110 E/W, 109 E/W, 108 E/W 106 E/W 105 E/W/N, 104 all, LC E, Lobby W, 107
E/W
100810CDW
01‐02 STOR1, 3' from E, 1' from N, 6' up ND
CDW01
1/2" pink DW w/ brown paper assoc. w/ joint compound
178 N, 179 S/N, 180 S, 181 S, 182 N/S, 183 N/S, 185 N, SEC1, STOR1, DOCK S, 187S, 190B S, 138 N, 173 N/S 172 N/S, 171 N/S, 174 N/S, 175 N, 170 N/S, 169 N/S, 167
N/S, 166A N, 168 N/S, 137E, 135 E/W, 134 E/W, 133 E/W, 165D, 132 E/W, 131 E/W, 130 E/W, 129 E/W, 128 E/W, 123 E, 127E/W, 126 E/W, 125 E/W, 124 W/E, 120 E/W, 119 E/W, 118 E/W, 117 E/W, 116 E/W, 115 E/W, 114 E/W, 113 E/W, 112 E/W, 111 E/W, 110 E/W, 109 E/W, 108 E/W 106 E/W 105 E/W/N, 104 all, LC E, Lobby W, 107
E/W
100810CDW
01‐03 Room 138, N wall, 1' from E, 5' up ND
Project # 2944.10
Material Code Homogenous Material Description Material Location(s) Sample # Sample Location (Room#) Result
CDW02
1/2" white drywall assoc. w/ joint compound
201 S, 202 W, 203 E/W, 204 E/W, 205 E/W, 206 E/W, 207 E/W, 208 E/W, 210 S, 211 N/S, 212 N, 213 N/S, 215 E/W, 216 E/W, 217 E, 218 E/W, 219 E, 220 E/W, 221 E, 222
E/W, 223 E/W, 224 N/S, 239 N/E, 239A N/E/W, 238 ALL, 236 N/W, 235 S, 234 S/W,
232 S/E
100610CDW
02‐01 Room 205 W wall, behind light switch plate ND
CDW02
1/2" white drywall assoc. w/ joint compound
201 S, 202 W, 203 E/W, 204 E/W, 205 E/W, 206 E/W, 207 E/W, 208 E/W, 210 S, 211 N/S, 212 N, 213 N/S, 215 E/W, 216 E/W, 217 E, 218 E/W, 219 E, 220 E/W, 221 E, 222
E/W, 223 E/W, 224 N/S, 239 N/E, 239A N/E/W, 238 ALL, 236 N/W, 235 S, 234 S/W,
232 S/E
100810CDW
02‐02 Room 236, W wall, behind door at floor ND
CDW02
1/2" white drywall, tan fibrous material and paint
201 S, 202 W, 203 E/W, 204 E/W, 205 E/W, 206 E/W, 207 E/W, 208 E/W, 210 S, 211 N/S, 212 N, 213 N/S, 215 E/W, 216 E/W, 217 E, 218 E/W, 219 E, 220 E/W, 221 E, 222
E/W, 223 E/W, 224 N/S, 239 N/E, 239A N/E/W, 238 ALL, 236 N/W, 235 S, 234 S/W,
232 S/E
100810CDW
02‐03B‐D
Room 232 E wall, 3' from south ND
CDW02 Joint compound
201 S, 202 W, 203 E/W, 204 E/W, 205 E/W, 206 E/W, 207 E/W, 208 E/W, 210 S, 211 N/S, 212 N, 213 N/S, 215 E/W, 216 E/W, 217 E, 218 E/W, 219 E, 220 E/W, 221 E, 222
E/W, 223 E/W, 224 N/S, 239 N/E, 239A N/E/W, 238 ALL, 236 N/W, 235 S, 234 S/W,
232 S/E
100810CDW
02‐03A Room 232 E wall, 3' from south 0.75% Chry
CK01 White caulk for exterior concrete 2nd floor, North side, ladder area, all around building
100710CK01‐
Behind ladder to 2nd floor roof ND
CK01 White caulk for exterior concrete 2nd floor, North side, ladder area, all around building
100710CK01‐
02 SE corner, 3' up ND
CK01 White caulk for exterior concrete 2nd floor, North side, ladder area, all around building
100710CK01‐
03 SW corner, 3' high ND
CK02 Light grey caulk Front courtyard
100710CK02‐
NE corner of courtyard, below window seal to ground ND
CTA01
1' x 2' ceiling tile, stretched fissure w/ small worm holes & brown adhesive B‐3 (B4) N/W walls
100710CTA0
1‐01 B‐3 (B4), W wall, 12' from N 0.25% Chry
CTA01
1' x 2' ceiling tile, stretched fissure w/ small worm holes & brown adhesive B‐3 (B4) N/W walls
100710CTA0
1‐02 N wall by door 0.5% Chry
DS01
Yelllow duct sealant assoc. w/ tin foil & fiberglass exterior duct insulation
178, 179, 180, 181, 182, 183, 184, 185, Dock above ceiling, 187, 190A, 191, 190B, 138, NHW1, 173, 172, NHW2, 171, 174, 175, 170, NHW3, 198, 169, 167, 166B, 166A, 197, 196, 195, 168, CHW2, CHW1, 130, 149, 150, 123, 126, 125, 124, 150, EHW1, 122, 121, 120, 116, 115, 114, 113, EHW2, 151, 153, 154, EHW2, 112, 111, 155A, 155B, 156, 157, 110, 109, 108, CHW4, 107, 106, 105, 104, CHWB (Lobby), Lobby, 2SHW, 2EHW, DS01, 107, B‐3
100410DS01‐
Room 178, 3' fromN, 5' from W, on duct above ceiling ND
DS01
Yelllow duct sealant assoc. w/ tin foil & fiberglass exterior duct insulation
178, 179, 180, 181, 182, 183, 184, 185, Dock above ceiling, 187, 190A, 191, 190B, 138, NHW1, 173, 172, NHW2, 171, 174, 175, 170, NHW3, 198, 169, 167, 166B, 166A, 197, 196, 195, 168, CHW2, CHW1, 130, 149, 150, 123, 126, 125, 124, 150, EHW1, 122, 121, 120, 116, 115, 114, 113, EHW2, 151, 153, 154, EHW2, 112, 111, 155A, 155B, 156, 157, 110, 109, 108, CHW4, 107, 106, 105, 104, CHWB (Lobby), Lobby, 2SHW, 2EHW, DS01, 107, B‐3
100810DS01‐
Lobby HW, 1' from N, 3' from
E ND
Project # 2944.10
Material Code Homogenous Material Description Material Location(s) Sample # Sample Location (Room#) Result
DS01
Yelllow duct sealant assoc. w/ tin foil & fiberglass exterior duct insulation
178, 179, 180, 181, 182, 183, 184, 185, Dock above ceiling, 187, 190A, 191, 190B, 138, NHW1, 173, 172, NHW2, 171, 174, 175, 170, NHW3, 198, 169, 167, 166B, 166A, 197, 196, 195, 168, CHW2, CHW1, 130, 149, 150, 123, 126, 125, 124, 150, EHW1, 122, 121, 120, 116, 115, 114, 113, EHW2, 151, 153, 154, EHW2, 112, 111, 155A, 155B, 156, 157, 110, 109, 108, CHW4, 107, 106, 105, 104, CHWB (Lobby), Lobby, 2SHW, 2EHW, DS01, 107, B‐3
100810DS01‐
03 HW above Room 148, S side ND
DS02
White duct sealant on tape around foil insulation 133, 132, 131, 148, 130, 129, 128, 123, 127, 126, 125, 124, 150, 122, 121, 120, 118, 117, 116, 151, 153, 154, 155A, 155B, CHW1, EHW1, EHW2
100510DS02‐
Room 133, SE corner, above ceiling tile 5% Chry
DS02
White duct sealant on tape around foil insulation 133, 132, 131, 148, 130, 129, 128, 123, 127, 126, 125, 124, 150, 122, 121, 120, 118, 117, 116, 151, 153, 154, 155A, 155B, CHW1, EHW1, EHW2
100810DS02‐
Hallway above 148, south side 5% Chry
DS02
White duct sealant on tape around foil insulation 133, 132, 131, 148, 130, 129, 128, 123, 127, 126, 125, 124, 150, 122, 121, 120, 118, 117, 116, 151, 153, 154, 155A, 155B, CHW1, EHW1, EHW2
100810DS02‐
Room 133, SW corner above grid 5% Chry
DT01
1.5" fiberglass duct insulation wrapped w/ foil, paper, & canvas Room B‐9, B‐8
100710DT01‐
01 B9, on duct above door ND
DT01
1.5" fiberglass duct insulation wrapped w/ foil, paper, & canvas Room B‐9, B‐8
100710DT01‐
B8, square duct running north‐ south, 4' from N, W side ND
DT02
1/2" fiberglass duct insulation wrapped w/ foil, paper, & canvas B‐3
100710DT02‐
01 NE duct ND
DT02
1/2" fiberglass duct insulation wrapped w/ foil, paper, & canvas B‐3
100710DT02‐
02 S duct, center ND
DT02
1/2" fiberglass duct insulation wrapped w/ foil, paper, & canvas B‐3
100810DT02‐
03 B‐3, center unit, E side ND
FLC01
White plaster/mud, friable, w/ yellow carpet mastic, floor leveling compound 165A (Conf A), 164 (Conf B), (10 locations in floor), 196, 120, 117, 206, 234
100510FLC0
1‐01 165A, 8' from N, 8' from W at floor ND
FLC01
White plaster/mud, friable, w/ yellow carpet mastic, floor leveling compound 165A (Conf A), 164 (Conf B), (10 locations in floor), 196, 120, 117, 206, 234
100810FLC0
1‐02 Room 206, W of door ND
FLC01
White plaster/mud, friable, w/ yellow carpet mastic, floor leveling compound 165A (Conf A), 164 (Conf B), (10 locations in floor), 196, 120, 117, 206, 234
100810FLC0
1‐03 Room 164, 10' from S floor, 15' from E ND
FTC01
9" x 9" white floor tile w/ green streaks
178, 179, 180, 181, 182, 183, 184, 185, 187, 190A, 191, 190B, 138, 173, 172 ,171, 174, 170, 189, 169, 167, 197, 139, 141, 143, 135, 133, 145, 165B, 165D, 146, 132, 130, 149, 129, 128, 123, 127, 126, 126A, 124, 150, 120a, 119, 118, 116, 115, 114, 113, 151, 153, 154, 112, 111, 155a, 155b, 156, 158a, 110, 109, 108, elevator, 210, 211, 212, 218, 221, 224, 225, 239A, 238, 232, B4, NHW3, NHW2, NHW1, CHW2, CHW1, EHW1, EHW2, CHW4, LC, 2SHW, 2EHW, 2NHW, 2WHW
100410FTC0
1‐01B Doorway of 178, 1' from N threshold 12% Chry
Project # 2944.10
Material Code Homogenous Material Description Material Location(s) Sample # Sample Location (Room#) Result
FTC01
Yellow carpet mastic, on top of floor tile
178, 179, 180, 181, 182, 183, 184, 185, 187, 190A, 191, 190B, 138, 173, 172 ,171, 174, 170, 189, 169, 167, 197, 139, 141, 143, 135, 133, 145, 165B, 165D, 146, 132, 130, 149, 129, 128, 123, 127, 126, 126A, 124, 150, 120a, 119, 118, 116, 115, 114, 113, 151, 153, 154, 112, 111, 155a, 155b, 156, 158a, 110, 109, 108, elevator, 210, 211, 212, 218, 221, 224, 225, 239A, 238, 232, B4, NHW3, NHW2, NHW1, CHW2, CHW1, EHW1, EHW2, CHW4, LC, 2SHW, 2EHW, 2NHW, 2WHW See FLC01 Doorway of 178, 1' from N threshold ND
FTC01 Black mastic
178, 179, 180, 181, 182, 183, 184, 185, 187, 190A, 191, 190B, 138, 173, 172 ,171, 174, 170, 189, 169, 167, 197, 139, 141, 143, 135, 133, 145, 165B, 165D, 146, 132, 130, 149, 129, 128, 123, 127, 126, 126A, 124, 150, 120a, 119, 118, 116, 115, 114, 113, 151, 153, 154, 112, 111, 155a, 155b, 156, 158a, 110, 109, 108, elevator, 210, 211, 212, 218, 221, 224, 225, 239A, 238, 232, B4, NHW3, NHW2, NHW1, CHW2, CHW1, EHW1, EHW2, CHW4, LC, 2SHW, 2EHW, 2NHW, 2WHW
100410FTC0
1‐01A Doorway of 178, 1' from N threshold 3% Chry
FTC01
9" x 9" white floor tile w/ green streaks assoc. w/ black mastic & yellow carpet adhesive
178, 179, 180, 181, 182, 183, 184, 185, 187, 190A, 191, 190B, 138, 173, 172 ,171, 174, 170, 189, 169, 167, 197, 139, 141, 143, 135, 133, 145, 165B, 165D, 146, 132, 130, 149, 129, 128, 123, 127, 126, 126A, 124, 150, 120a, 119, 118, 116, 115, 114, 113, 151, 153, 154, 112, 111, 155a, 155b, 156, 158a, 110, 109, 108, elevator, 210, 211, 212, 218, 221, 224, 225, 239A, 238, 232, B4, NHW3, NHW2, NHW1, CHW2, CHW1, EHW1, EHW2, CHW4, LC, 2SHW, 2EHW, 2NHW, 2WHW
100810FTC0
1‐02 Room 238, S wall, center Held at lab
FTC01
9" x 9" white floor tile w/ green streaks assoc. w/ black mastic & yellow carpet adhesive
178, 179, 180, 181, 182, 183, 184, 185, 187, 190A, 191, 190B, 138, 173, 172 ,171, 174, 170, 189, 169, 167, 197, 139, 141, 143, 135, 133, 145, 165B, 165D, 146, 132, 130, 149, 129, 128, 123, 127, 126, 126A, 124, 150, 120a, 119, 118, 116, 115, 114, 113, 151, 153, 154, 112, 111, 155a, 155b, 156, 158a, 110, 109, 108, elevator, 210, 211, 212, 218, 221, 224, 225, 239A, 238, 232, B4, NHW3, NHW2, NHW1, CHW2, CHW1, EHW1, EHW2, CHW4, LC, 2SHW, 2EHW, 2NHW, 2WHW
100810FTC0
1‐03 B3 (B4), SW corner Held at lab
FTC02
12" x 12" gray floor tile w/ gray & white streaks SEC 1, STOR 1
100410FTC0
2‐01B SEC1, 4' from N, 1' from E, behind door ND
FTC02 Black mastic SEC 1, STOR 1
100410FTC0
2‐01A SEC1, 4' from N, 1' from E, behind door 7% Chry
FTC02
12" x 12" gray floor tile w/ gray & white streaks SEC 1, STOR 1
100810FTC0
2‐02 STOR1, 11' from N, 3' from E ND
FTC03
12" x 12" white floor tile w/ gray streaks 144, 107
100510FTC0
3‐01B Room 144, E wall, S end ND
FTC03 Black mastic 144, 107
100510FTC0
3‐01A Room 144, E wall, S end 8% Chry
FTC03
12" x 12" white floor tile w/ gray streaks 144, 107
100810FTC0
3‐02B Room 144, NW corner, 3' from W ND
FTC03 Black mastic 144, 107
100810FTC0
3‐02A Room 144, NW corner, 3' from W 6% Chry
FTC04
12" x 12" white tile w/ beige marble & yellow mastic Lobby entry way
100610FTC0
4‐01 Lobby entry way, NW corner ND
FTC04
12" x 12" white tile w/ beige marble & yellow mastic Lobby entry way
100810FTC0
4‐02 Lobby entryway, NW corner ND
Project # 2944.10
Material Code Homogenous Material Description Material Location(s) Sample # Sample Location (Room#) Result
LIP01
White 2' x 4' lay in panel w/ random fissure & pin hole
178, 179, 180, 181, 183, 184, 185, dock, 187, 190a, 191, 190b, 138, NHW1, 173, 172, 171, 174, 175, 170, NHW3, 198, NHW2, 169, 167, 166A, 166B, 197, 165C, 196, 168, CHW2, CHW1, 139, 141, 137, 140, 143, 136, 135, 144, 134, 133, 145, 165A, 164, 165D, 132, 131, 130, 149, 129, 128, 123, 127, 126, 126A, 125, 124, 117, 116, 115, 114, 113, 151, 153, 154, EHW2, 112, 111, 155A, 156, 157, 110, 109, 108, CHW4, 106, 105, 104, 2SHW, 201, 202, 203, 204, 205, 206, 207, 208, 209, 2EHW, 210, 211, 212, 213, 214, 215, 216, 217, 218, 219, 220, 221, 222, 238, 236, 235, 232, 107
100410LIP01‐
Room 178, E wall, 3' from N at ceiling ND
LIP01
White 2' x 4' lay in panel w/ random fissure & pin hole
178, 179, 180, 181, 183, 184, 185, dock, 187, 190a, 191, 190b, 138, NHW1, 173, 172, 171, 174, 175, 170, NHW3, 198, NHW2, 169, 167, 166A, 166B, 197, 165C, 196, 168, CHW2, CHW1, 139, 141, 137, 140, 143, 136, 135, 144, 134, 133, 145, 165A, 164, 165D, 132, 131, 130, 149, 129, 128, 123, 127, 126, 126A, 125, 124, 117, 116, 115, 114, 113, 151, 153, 154, EHW2, 112, 111, 155A, 156, 157, 110, 109, 108, CHW4, 106, 105, 104, 2SHW, 201, 202, 203, 204, 205, 206, 207, 208, 209, 2EHW, 210, 211, 212, 213, 214, 215, 216, 217, 218, 219, 220, 221, 222, 238, 236, 235, 232, 107
100810LIP01‐
02 Room 164, W wall, 12' from S ND
LIP01
White 2' x 4' lay in panel w/ random fissure & pin hole
178, 179, 180, 181, 183, 184, 185, dock, 187, 190a, 191, 190b, 138, NHW1, 173, 172, 171, 174, 175, 170, NHW3, 198, NHW2, 169, 167, 166A, 166B, 197, 165C, 196, 168, CHW2, CHW1, 139, 141, 137, 140, 143, 136, 135, 144, 134, 133, 145, 165A, 164, 165D, 132, 131, 130, 149, 129, 128, 123, 127, 126, 126A, 125, 124, 117, 116, 115, 114, 113, 151, 153, 154, EHW2, 112, 111, 155A, 156, 157, 110, 109, 108, CHW4, 106, 105, 104, 2SHW, 201, 202, 203, 204, 205, 206, 207, 208, 209, 2EHW, 210, 211, 212, 213, 214, 215, 216, 217, 218, 219, 220, 221, 222, 238, 236, 235, 232, 107
100810LIP01‐
03 HW between 173 & 174 ND
LIP01
White 2' x 4' lay in panel w/ random fissure & pin hole
178, 179, 180, 181, 183, 184, 185, dock, 187, 190a, 191, 190b, 138, NHW1, 173, 172, 171, 174, 175, 170, NHW3, 198, NHW2, 169, 167, 166A, 166B, 197, 165C, 196, 168, CHW2, CHW1, 139, 141, 137, 140, 143, 136, 135, 144, 134, 133, 145, 165A, 164, 165D, 132, 131, 130, 149, 129, 128, 123, 127, 126, 126A, 125, 124, 117, 116, 115, 114, 113, 151, 153, 154, EHW2, 112, 111, 155A, 156, 157, 110, 109, 108, CHW4, 106, 105, 104, 2SHW, 201, 202, 203, 204, 205, 206, 207, 208, 209, 2EHW, 210, 211, 212, 213, 214, 215, 216, 217, 218, 219, 220, 221, 222, 238, 236, 235, 232, 107
100810LIP01‐
04 Room 156, N wall, center ND
LIP01
White 2' x 4' lay in panel w/ random fissure & pin hole
178, 179, 180, 181, 183, 184, 185, dock, 187, 190a, 191, 190b, 138, NHW1, 173, 172, 171, 174, 175, 170, NHW3, 198, NHW2, 169, 167, 166A, 166B, 197, 165C, 196, 168, CHW2, CHW1, 139, 141, 137, 140, 143, 136, 135, 144, 134, 133, 145, 165A, 164, 165D, 132, 131, 130, 149, 129, 128, 123, 127, 126, 126A, 125, 124, 117, 116, 115, 114, 113, 151, 153, 154, EHW2, 112, 111, 155A, 156, 157, 110, 109, 108, CHW4, 106, 105, 104, 2SHW, 201, 202, 203, 204, 205, 206, 207, 208, 209, 2EHW, 210, 211, 212, 213, 214, 215, 216, 217, 218, 219, 220, 221, 222, 238, 236, 235, 232, 107
100810LIP01‐
05 Room 151, S wall, center ND
LIP02
White 2' x 4' lay in panel with width‐ wise fissures & pin holes 173, 3 replacement tiles, W wall, 165C
100410LIP02‐
Room 173, 1' from W, 2' from
S, above door ND
Project # 2944.10
Material Code Homogenous Material Description Material Location(s) Sample # Sample Location (Room#) Result
LIP03
White 2' x 4' lay in panel constellation pattern Room 173, 3 replacement tiles, E wall
100410LIP03‐
Room 173, 6' from S, 2' from
E ND
LIP04
White 1' x 2' lay in panel stretched fissure small pinhole w/foil backing Room 155B
100610LIP04‐
01 Room 155B, center ND
LIP05
Blue 1' x 1' lay in panel width wise fissure medium pinhole Lobby closet ceiling
100610LIP05‐
01 Center ND
LIP05
Blue 1' x 1' lay in panel width wise fissure medium pinhole Lobby closet ceiling
100810LIP05‐
02 North end ND
LIP06
White 2' x 2' lay in panel rough texture Lobby and Lobby Hallway
100610LIP06‐
01 North end center ND
LIP06
White 2' x 2' lay in panel rough texture Lobby and Lobby Hallway
100810LIP06‐
Lobby Hallway 25' from N, 6' from W ND
LIP06
White 2' x 2' lay in panel rough texture Lobby and Lobby Hallway
100810LIP06‐
Lobby S wall over door to
Hallway, 5' from W ND
LIP07
White 2' x 4' lay in panel fiberglass painted texture Room 239 and 234
100610LIP07‐
Room 239, 6' from W on S wall ND
LIP07
White 2' x 4' lay in panel fiberglass painted texture Room 239 and 234
100810LIP07‐
Room 234, 5' from N at W wall ND
LIP07
White 2' x 4' lay in panel fiberglass painted texture Room 239 and 234
100810LIP07‐
Room 234, 8' from N, 4' from
E ND
MA01
Green mastic assoc. w/styrofoam exterior insulation
178, 179, 180, 181, 192, 183, 184, 185, 187, 173, 172, 171, 174, 175, 170, 169, 167, 166, 168, CHWZ, CHW1, 137, 135, 136, 134, 165A, 164, 132, 131, 148, 130, 129, 128, 123, 124, 127, 126, 126A, 125, 124, 123, 150, 122, 121, 120, 120A, 119, 118, 117, 116, 115, 114, 113, 151, 112, 111, 110, 109, 108, 107, 106, 105, 104, CHW3 Lobby, Lobby, 201, 202, 203, 204, 205, 206, 207, 208, 209, 210, 211, 212, 213, 214, 215, 216, 217, 218, 219, 220, 221, 222, 223, 224, 225, 226…
This is the start of the file's text. The full file is on GovTribe.