12620 Exhibit 2 Site Plans and Standard Drawings.pdf

PDF 3 MB Posted

Attached to
ESB OR 58 MP 86 Stockpile Fence Project
Solicitation number
S-73000-00012620
Issued by
Jackson County, Oregon

About this file

This file contains site plans and standard drawings from the Oregon Department of Transportation, including detailed specifications for barbed and woven wire fencing installations. The documents show aerial views of a stockpile site along the Willamette Highway and detailed engineering drawings for fence construction (RD810) and fence gates (RD820).

The first aerial image shows a stockpile site with dimensions of approximately 725 feet by 50 feet adjacent to the Willamette Highway. The engineering drawings provide comprehensive specifications for three types of fencing (Type 1, Type 1-5W, and Type 2), including detailed measurements for posts, braces, wire spacing, and gate installations. The drawings include specific material requirements for both wood and metal components, with tables detailing dimensions, post spacing requirements, and material specifications. The effective dates for these standard drawings are December 1, 2024 through May 31, 2025.

View the file

Other files

File Type Posted
12620 RFCQ Add 1.pdf PDF
12620 ESB Fence Project RFCQ_Attach.pdf PDF
25-751 FSMC 2025-2026ODEApproved.doc DOC document
12620 ESB Fence Project RFCQ.pdf PDF
12620 Prelim Bid Results.xlsx XLSX spreadsheet
12620 ESB Fence Project RFCQ_Attach REVISED.pdf PDF

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

Exhibit 2 - Site Plans and Standard and Drawings

Stockpile Site

RD810

FENCES

BARBED AND WOVEN WIRE

R D

.d g n

13-JAN-2020N/A

J U

L xxxxxxxxxxxx x x x x x xxxxx x x x x x xxxxxx x x xxx x xx x xx x x x x x x x x x x x x xxxxx x x x x x x x x x x x xxxxxxx x x x x x x x xxx xx x x x xx x xxx xxxxx x x x x x x x x x x x x x xxx x x x xx x x x x x x xx xx x x x x x x xx x x x x x x xx

B

C

WIRES

NO. OF

10"

14"

10"

12"

Type 1-5W

Type 1

1 1

SQUARE

SHAPE

a a a a b b

FENCE C SPACING

stake

1"x2"x12"

Lever metal posts)

(See wood or

Gate post from end of locking bar.

post and approx. 5" welded or bolted to gate

" short link coil chain4 line post material)

4'-4" (Metal

End bar Length

3" normal

Gate post

6 gauge thkn. wire loop wood line post material)

Length 4'-4" (Metal or

End bar

6 gauge thkn. wire loop

3" normal m in m in

Ground linewire loop

6 gauge thkn.

line post material) approx.2'-2" (Metal

Locking bar

Fence stays gauge wire2

6 gauge thkn. wire loop

30" (Type 2)

(33' max. for type 2 fence material)

Width as indicated on plan

5'-6" max. 5'-6" max. 5'-6" max.

3 For wooden stays, see Type 1 fence details.

2 For details not shown see fence type.

1 Match adjointing fence type.

Fence material Fence material Fence materialNOTES:

thkn. wire gauge2

Fence stays

4 or 5 barbed wires

2" min.

Ground line

Post

NOTE:

1 5'-6" 5'-6" ta b le b e lo w

F o r s p a c in g s e e for woven wire fabric.

Horizontal wires to be stapled are: single wires and a minimum of 4 wires on the ground.

Hemlock or Western Pine, spaced as shown for wire stays and to rest firmly

Stays to be 2"x2"x52" min. length, sound, untreated Douglas Fir, Western

Wooden Stays to be used in areas of heavy snowfall or snow drifts over 36".

wire fabric

Rectangular woven

832-6-12

Design number details see Type 1 fence

For wooden stays, NOTE:

Recommendation R9-47.

Simplified Practice

U.S. Dept. of Commerce

Post2

"Barbed wire

Ground line

Unit A required at gate post.

fence line at intersection with new fence line.

Either Unit A or Units A & B are required in existing

Over 330

20-330

20 or Less

Types

1-5W &

1, A & B

A

None

FENCE

R

(ft) REQUIRED

UNITS

TABLE 1 (For wood posts)

TABLE 2

TABLE 3

3" to 4"

All Types 660' 16'-6" 7'-6" 6'-6" 4'-4" 3'-2" 2'-2" 7'-8" 9"-22"

ASTM A-7021.33 lb or U-bar

Tee Channel 3"x3"3"Line Post

Brace Rail

Brace or

"2 to 5

"2

Other Post 4" to 7" 5"

4"

5"x5"

4"x4" Tubular

Angle

Tubular

Angle

3.19 lb b

4.1 lb "4

"x2

"x22

" O.D.8

"4

2"x2"x

" +/- O.D.2 min.-max. min. avg.

FENCE

max.

R P min.

L min.

L H min.

D min.

D min.

B min.-max.

X

MEMBER

SMALL END (in)

DIAMETER OF

ROUND

(in) nominal

SIZE

nominal

PER (ft)

WEIGHT

nominal

SIZE

WOOD METAL

Max. taper 1":48".

in each dimension.

Max. allowable size 1" additional

In accordance with ASTM A 702.

In accordance with AASHTO M 181.

corner post unit

End, gate or m in

12"

Brace min.

Concrete footing min.

nom. wt. 0.67 lbs

Anchor plate footing

Concrete

Brace

Line post

Intermediate end post line

Ground

Brace min.

18" min.

min.

2"

D H

L

X

B

P

R

B

X

H

L

D

12"

H D

L

22" round

20" sq. or

22" round

18" sq. or

22" round

20" sq. or

22" round

18" sq. or

2"

2"

8'-3"8'-3"

Wood brace rail steel dowel

"dia. x4"8

Wood post

Brace post thkn. wire

4 stands of 9 gauge

Brace guys Brace post

Brace rail Intermediate end post

3. For cross sectional dimensions of members see Table 3.

2. Line post spacing same as dimension P.

1. For dimensions indicated by letter see Table 2.

NOTES:

1"x2"x12" stake

Lever

8'-3" 8'-3"

R

P

H

L

D

D

L

H

Brace post

D

L

H

UNIT A UNIT B

For units required see Table 1 corner post unit(s)

End, gate or

Brace rail wire

9 gauge thkn.

4 strands of

Brace guy guy at gate posts

Additional brace line

Ground

Line post

21 21 21

GATEWAY

TYPES 1 , & 1-5W

BRACE RAIL CONNECTIONMETAL POSTS

WOOD POSTS

TYPE 2

TYPE 2TYPE 1-5WTYPE 1

7. Add fence grounding as required.

6. See project plans for details not shown.

5. See Std. Dwg. RD820 for fence gates.

4. All concrete shall be commercial grade concrete.

3. For shapes, weights and dimensions of members see Table 3.

2. Line post spacing same as dimension P.

1. For dimensions indicated by letter see Table 2.

GENERAL NOTES FOR ALL DETAILS ON THIS SHEET:

TABLE OF DIMENSIONS

the current Oregon Standard Specifications.

All materials shall be in accordance with

DATE REVISION DESCRIPTION

OREGON STANDARD DRAWINGS

DATE

SDR

BOOK NO.

CALC.

Effective Date: December 1, 2024 - May 31, 2025

Professional Engineer.

first consulting a Registered and should not be used without sole responsibility of the user principles and practices, is the generally accepted engineering designed in accordance with

Standard Drawing, while

The selection and use of this

RD820

FENCE GATES

R D

.d g n

13-JAN-2020N/A

J U

L

RODS

NUMBERDOUBLE GATESINGLE GATE

Min. Avg.(in)

NOM. DIA.

(in)

NOM. DIA.

DIA. OF SMALL END (in)

(in)

NOM. SIZE

(in)

NOM. DIA.

(lb/ft)

MIN. WT.

(lb/ft)

MIN. WT.

(lb/ft)

MIN. WT.

Max.Min.

17 thru 20

12 thru 16

7 thru 11

UP thru 6

33 thru 40

23 thru 32

13 thru 22

UP thru 12

3.65

2.72

2.27

1.68

2.27

2.27

1.68

10x10

8x8

6x6

6x6

18.97

18.97

9.11

5.79

1 2

Brace(s) to be equally spaced when required (See Table)

Schedule 40 galv. steel pipe brace (Typ.)

(See Table) steel pipe frame

Schedule 40 galv.

two are required)

Truss rod (Where

(See Table)

Gate post

(See Table)

" dia.8

Truss rod, or chain link fabric

Woven wire fabric

(See Table)

Gate post

Finish grade

Gate opening (as shown on plans)

20' single gate

Max. opening 40' double gate

For length, setting and bracing details see end posts, Std. Dwg. RD810.

to be as indicated for single gate installation of the wider gate width.

At a double gate installation with unequal width gates, size of both posts

Gate posts on each side of a gate opening to be the same size.

Max. taper 1" in 4'

4. Add fence grounding as required.

3. See project plans for details not shown.

2. See Std. Dwg. RD810 for details not shown.

1. Gates shown are for use with Fence Types 1, 1-5W and 2.

GENERAL NOTES FOR ALL DETAILS ON THIS SHEET:

GATE POSTS

GATE COMPONENTS

WOOD STEEL

STEEL PIPE BRACE

SCHEDULE 40 GALV.

STEEL PIPE FRAME

SCHEDULE 40 GALV.

(ft)

GATE OPENING ROUND SQUARE

STEEL PIPE

SCHEDULE 40 GALV.

TRUSS

the current Oregon Standard Specifications.

All materials shall be in accordance with

DATE REVISION DESCRIPTION

OREGON STANDARD DRAWINGS

DATE

SDR

BOOK NO.

CALC.

Effective Date: December 1, 2024 - May 31, 2025

Professional Engineer.

first consulting a Registered and should not be used without sole responsibility of the user principles and practices, is the generally accepted engineering designed in accordance with

Standard Drawing, while

The selection and use of this