C04_Drawing.pdf

PDF 55 KB Posted

Attached to
MSB Lab Floor Coating Repairs
Solicitation number
124PCA27Q0008
Issued by

About this file

This document is an architectural floor plan for the U.S. Department of Agriculture's Agricultural Research Service Eastern Regional Research Center in Wyndsor, Pennsylvania. The drawing depicts the second floor plan view for MSB Floor Coating Repairs at the facility located at 600 East Mermaid Lane, Windsor PA, 19454.

The plan identifies areas requiring chemical resistant resilous coated concrete flooring repairs throughout the Mechanical Services Building. Key areas marked for repair work include spaces labeled as FRZR BOX 4, ENV BOX 3, ENV BOX 1, ENV BOX 2, MEN (restroom), WOMEN (restroom), and COOK HOUSE. The shaded areas (indicated by diagonal hatching) represent existing surfaces requiring treatment, while outlined boxes denote enclosed spaces. General notes specify that repairs involve chemical resistant resilous coated concrete flooring, with areas to be prepped for new material per manufacturers' recommendations. The work scope includes treating cracks, control joints, and expansion joints, applying base coat epoxy and finish coat of chemical resistant resilous coating with appropriate drying times and texturizing additives. The laboratory space requires finishes compatible with chlorinated cleaning solutions and cleanroom specifications. The document is dated 06/12/2008 and includes approval signatures.

View the file

Other files

File Type Posted
C04_SOWv2.docx DOCX document
C04_Sol_124PCA27Q0008.pdf PDF
C04_SOW.docx DOCX document
C04_Wage Determination.pdf PDF

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

AutoCAD SHX Text

ROOF LINE, 2ND FLR, REF

AutoCAD SHX Text

FRZR BOX 4

AutoCAD SHX Text

ENV BOX 3

AutoCAD SHX Text

ENV BOX 1

AutoCAD SHX Text

ENV BOX 2

AutoCAD SHX Text

MEN

AutoCAD SHX Text

WOMEN

AutoCAD SHX Text

COOK HOODS

AutoCAD SHX Text GENERAL NOTES 1. This drawing repairs and recoats Chemical resistant resinous This drawing repairs and recoats Chemical resistant resinous coated concrete flooring in the Mechanical Services Building (MSB), second floor laboratory at Eastern Regional Research Center, 600 East Mermaid Lane, Wyndmoor Pa, 19454. 2. Areas shown thusly including existing cove base Areas shown thusly including existing cove base shall be repaired and recoated. 3. Areas shall be prepped for new material in accordance with Areas shall be prepped for new material in accordance with manufacturers recommendations. 4. Treat cracks, control joints and expansion joints. Treat cracks, control joints and expansion joints. 5. Apply base coat of pure epoxy and finish coat of chemical Apply base coat of pure epoxy and finish coat of chemical resistant polyaspartic including a texturing additive providing and non-skid surface. 6. The laboratory is use for biological work. Finishes must The laboratory is use for biological work. Finishes must meet cleanroom requirements and be compatible with chlorinated cleaning solutions.

AutoCAD SHX Text

FACILITIES ENGINEERING

AutoCAD SHX Text

DATE

AutoCAD SHX Text

WYNDMOOR, PA. 19118

AutoCAD SHX Text

EASTERN REGIONAL RESEARCH CENTER

AutoCAD SHX Text

AGRICULTURAL RESEARCH SERVICE

AutoCAD SHX Text

U.S. DEPARTMENT OF AGRICULTURE

AutoCAD SHX Text

NO. DATE APPROVED

AutoCAD SHX Text

REVISIONS

AutoCAD SHX Text

APPROVED

AutoCAD SHX Text

SCALE

AutoCAD SHX Text

CHECKED

AutoCAD SHX Text

DRAWN

AutoCAD SHX Text

MSB FLOOR COATING REPAIRS

AutoCAD SHX Text

GOLDBERG

AutoCAD SHX Text

SECOND FLOOR PLAN VIEW

AutoCAD SHX Text 08/10/2026

Sheets and Views
msb floor repair mods-Floor Painting

File details come from the government source that posted it. Updated .