This document package includes construction drawings and specifications for upgrading the Warm Springs Recreation Area water system located on the Bitterroot National Forest in Montana. The project involves decommissioning an existing well, installing a new well with pitless adapter, upgrading the pump house and buried water lines, and connecting to the existing water distribution system. Work will be performed under solicitation number 1240LU24Q0004 issued by the U.S. Department of Agriculture Forest Service. Bids are due by June 30, 2023, with award anticipated in July and work expected to be completed by September 30, 2023.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

NO. DATEBYREVISION DESCRIPTION

G-1

SHEET NO.

SET NO.

PROJECT:

DATE:

SHEET INDEX

DATE

PROJECT NUMBER

N

WARM SPRINGS WELL UPGRADE

U.S. DEPARTMENT OF AGRICULTURE

FOREST SERVICE

REGION ONE

BITTERROOT NATIONAL FOREST

DARBY/SULA DISTRICT

RAVALLI COUNTY

AREA MAP

MONTANA / IDAHO INDEX MAP

PROJECT LOCATION

LOCATION MAP

TO HAMILTON, MT

PROJECT ENGINEER

BITTERROOT NATIONAL FOREST

DATE

APPROVED BY:

RECOMMENDED BY:

FOREST SUPERVISOR

BITTERROOT NATIONAL FOREST

DATE

APPROVED BY:

DESIGNED BY:

FOREST ENGINEER

BITTERROOT NATIONAL FOREST

DATE

DISTRICT RANGER

BITTERROOT NATIONAL FOREST

DATE

APPROVED BY:

EAST ZONE ENVIRONMENTAL

ENGINEER

NORTHERN REGION

DATE

APPROVED BY:

DIRECTOR OF ENGINEERING

NORTHERN REGION

DATE

Sheet List Table

Sheet Number Sheet Title

G-1 TITLE

C-1 EXISTING CONDITIONS

C-2 DEMOLITION PLAN

C-3 SITE PLAN

S-1 PUMP HOUSE PLAN

S-2 PUMP HOUSE PLUMBING DETAIL

D-1 DETAILS

AutoCAD SHX Text C:\Users\jcatanach\Box\01. justin.catanach Workspace\Catanach Workspace\Warm Springs Water System\Drawing Packages\Plans and SHEETSET\DWG\R01_Title.dwg

AutoCAD SHX Text

NOT TO SCALE

AutoCAD SHX Text

NOT TO SCALE

AutoCAD SHX Text

NOT TO SCALE

0+00

W

W

W

W

W

W

W

W

W W

W

W

W W

W

W

W

W W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

N W

DWG SHEET NO.

OF

SHEET

9/2 8/1

8 0 7:

M

AR

KL

F

CA

D

ST

AN

DA

RD

S\

AG

EN

CY

S

TA

ND

AR

DS

\F

OR

ES

T

SE

RV

IC

E\

NF

S-

CT

B.

DW

G;

CHECKEDDESIGNERDATE

DRAWING TITLE

United States Department of Agriculture Forest Service

NO. DATEBYREVISION DESCRIPTION

DARBY/SULA DISTRICT

BITTERROOT NATIONAL FOREST

WARM SPRINGS WELL

UPGRADE

NORTHERN REGION

R01 EXISTING CONDITIONS

12/20/2022 JCAT SBOEL 2

C-1

EXISTING SST

EXISTING SST

EXISTING PUMPHOUSE

AND PUMPHOUSE WELL

EXISTING HAND PUMP,

LOWER WELL,

AND CONCRETE PAD

WATER SPIGOT

WATER SPIGOT

HOST SITE

WATER HOOKUP

HOSE BIBB

DRAIN

W

LEGEND

EXISTING WATER

WOODEN PIPE (S.U.)

Feet

0 100 200

AutoCAD SHX Text

PROJECT NAME

AutoCAD SHX Text F

AutoCAD SHX Text O

AutoCAD SHX Text R

AutoCAD SHX Text E

AutoCAD SHX Text S

AutoCAD SHX Text T

AutoCAD SHX Text S

AutoCAD SHX Text E

AutoCAD SHX Text R

AutoCAD SHX Text V

AutoCAD SHX Text I

AutoCAD SHX Text C

AutoCAD SHX Text E

AutoCAD SHX Text D

AutoCAD SHX Text E

AutoCAD SHX Text P

AutoCAD SHX Text A

AutoCAD SHX Text R

AutoCAD SHX Text T

AutoCAD SHX Text M

AutoCAD SHX Text E

AutoCAD SHX Text N

AutoCAD SHX Text T

AutoCAD SHX Text O

AutoCAD SHX Text F

AutoCAD SHX Text A

AutoCAD SHX Text G

AutoCAD SHX Text R

AutoCAD SHX Text I

AutoCAD SHX Text C

AutoCAD SHX Text U

AutoCAD SHX Text L

AutoCAD SHX Text T

AutoCAD SHX Text U

AutoCAD SHX Text R

E

0+00

W

W

W

W

W

W

W

W

W W

W

W

W W

W

W

W

W W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

N W

DWG SHEET NO.

OF

SHEET

9/2 8/1

8 0 7:

M

AR

KL

F

CA

D

ST

AN

DA

RD

S\

AG

EN

CY

S

TA

ND

AR

DS

\F

OR

ES

T

SE

RV

IC

E\

NF

S-

CT

B.

DW

G;

CHECKEDDESIGNERDATE

DRAWING TITLE

United States Department of Agriculture Forest Service

NO. DATEBYREVISION DESCRIPTION

DARBY/SULA DISTRICT

BITTERROOT NATIONAL FOREST

WARM SPRINGS WELL

UPGRADE

NORTHERN REGION

R01 DEMOLITION PLAN

12/20/2022 JCAT SBOEL 3

C-2

DECOMMISSION EXISTING

WELL

DEMOLISH CONCRETE SLAB.

DISASSEMBLE AND REMOVE

EXISTING HAND PUMP AND

DROP PIPE TO BE RETURNED

TO GOVENRMENT.

Feet

0 100 200

W

LEGEND

EXISTING WATER

WOODEN PIPE (S.U.)

AutoCAD SHX Text

PROJECT NAME

AutoCAD SHX Text F

AutoCAD SHX Text O

AutoCAD SHX Text R

AutoCAD SHX Text E

AutoCAD SHX Text S

AutoCAD SHX Text T

AutoCAD SHX Text S

AutoCAD SHX Text E

AutoCAD SHX Text R

AutoCAD SHX Text V

AutoCAD SHX Text I

AutoCAD SHX Text C

AutoCAD SHX Text E

AutoCAD SHX Text D

AutoCAD SHX Text E

AutoCAD SHX Text P

AutoCAD SHX Text A

AutoCAD SHX Text R

AutoCAD SHX Text T

AutoCAD SHX Text M

AutoCAD SHX Text E

AutoCAD SHX Text N

AutoCAD SHX Text T

AutoCAD SHX Text O

AutoCAD SHX Text F

AutoCAD SHX Text A

AutoCAD SHX Text G

AutoCAD SHX Text R

AutoCAD SHX Text I

AutoCAD SHX Text C

AutoCAD SHX Text U

AutoCAD SHX Text L

AutoCAD SHX Text T

AutoCAD SHX Text U

AutoCAD SHX Text R

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

W

DWG SHEET NO.

OF

SHEET

9/2 8/1

8 0 7:

M

AR

KL

F

CA

D

ST

AN

DA

RD

S\

AG

EN

CY

S

TA

ND

AR

DS

\F

OR

ES

T

SE

RV

IC

E\

NF

S-

CT

B.

DW

G;

CHECKEDDESIGNERDATE

DRAWING TITLE

United States Department of Agriculture Forest Service

NO. DATEBYREVISION DESCRIPTION

DARBY/SULA DISTRICT

BITTERROOT NATIONAL FOREST

WARM SPRINGS WELL

UPGRADE

NORTHERN REGION

R01 SITE PLAN

12/20/2022 JCAT SBOEL 4

C-3

N

W

LEGEND

EXISTING WATER

PROPOSED WATER LINE

W

81 FT OF 1-1/4"

IN. HDPE 3408 DR11 PIPE

INSTALL NEW WELL

CAP, PUMP, DROP PIPE

AND PITLESS ADAPTER.

SEE SHEET 7

TO HOST SITE

TO REST OF

CAMPGROUND

PUMP HOUSE

Feet

0 20 40

AutoCAD SHX Text

PROJECT NAME

AutoCAD SHX Text F

AutoCAD SHX Text O

AutoCAD SHX Text R

AutoCAD SHX Text E

AutoCAD SHX Text S

AutoCAD SHX Text T

AutoCAD SHX Text S

AutoCAD SHX Text E

AutoCAD SHX Text R

AutoCAD SHX Text V

AutoCAD SHX Text I

AutoCAD SHX Text C

AutoCAD SHX Text E

AutoCAD SHX Text D

AutoCAD SHX Text E

AutoCAD SHX Text P

AutoCAD SHX Text A

AutoCAD SHX Text R

AutoCAD SHX Text T

AutoCAD SHX Text M

AutoCAD SHX Text E

AutoCAD SHX Text N

AutoCAD SHX Text T

AutoCAD SHX Text O

AutoCAD SHX Text F

AutoCAD SHX Text A

AutoCAD SHX Text G

AutoCAD SHX Text R

AutoCAD SHX Text I

AutoCAD SHX Text C

AutoCAD SHX Text U

AutoCAD SHX Text L

AutoCAD SHX Text T

AutoCAD SHX Text U

AutoCAD SHX Text R

1 2

Ø3"

DWG SHEET NO.

OF

SHEET

9/2 8/1

8 0 7:

M

AR

KL

F

CA

D

ST

AN

DA

RD

S\

AG

EN

CY

S

TA

ND

AR

DS

\F

OR

ES

T

SE

RV

IC

E\

NF

S-

CT

B.

DW

G;

CHECKEDDESIGNERDATE

DRAWING TITLE

United States Department of Agriculture Forest Service

NO. DATEBYREVISION DESCRIPTION

DARBY/SULA RANGER DISTRICT

BITTERROOT NATIONAL FOREST

WARM SPRINGS WELL UPGRADE

NORTHERN REGION

R01 PUMP HOUSE

PLAN VIEW

2/22/2023 JCAT SBOEL 5

S-1

EXISTING PUMP HOUSE

PROPOSED PUMP HOUSE

NOTES

1. WELL SHALL BE ABANDONED IN ACCORDANCE WITH

ARM 36.21.670 THROUGH 36.21.678.

2. WELL CASING SHALL BE CUT FLUSH WITH CONCRETE

FLOOR. MTDEQ VARIANCE FORM IS THE

RESPONSIBILITY OF THE CONTRACTOR.

3. PRESSURE RELIEF PIPE SHALL HAVE AN ELBOW

POINTING DOWN AND SHALL HAVE A SCREENED OUTLET

PRESSURE RELIEF PIPE DETAIL

PROPOSED WATER SYTEM

AutoCAD SHX Text P

AutoCAD SHX Text

STORAGE TANK

AutoCAD SHX Text

SHELVING

AutoCAD SHX Text M

AutoCAD SHX Text

PROJECT NAME

AutoCAD SHX Text F

AutoCAD SHX Text O

AutoCAD SHX Text R

AutoCAD SHX Text E

AutoCAD SHX Text S

AutoCAD SHX Text T

AutoCAD SHX Text S

AutoCAD SHX Text E

AutoCAD SHX Text R

AutoCAD SHX Text V

AutoCAD SHX Text I

AutoCAD SHX Text C

AutoCAD SHX Text E

AutoCAD SHX Text D

AutoCAD SHX Text E

AutoCAD SHX Text P

AutoCAD SHX Text A

AutoCAD SHX Text R

AutoCAD SHX Text T

AutoCAD SHX Text M

AutoCAD SHX Text E

AutoCAD SHX Text N

AutoCAD SHX Text T

AutoCAD SHX Text O

AutoCAD SHX Text F

AutoCAD SHX Text A

AutoCAD SHX Text G

AutoCAD SHX Text R

AutoCAD SHX Text I

AutoCAD SHX Text C

AutoCAD SHX Text U

AutoCAD SHX Text L

AutoCAD SHX Text T

AutoCAD SHX Text U

AutoCAD SHX Text R

I N

M

I N

T Y

P

DWG SHEET NO.

OF

SHEET

9/2 8/1

8 0 7:

M

AR

KL

F

CA

D

ST

AN

DA

RD

S\

AG

EN

CY

S

TA

ND

AR

DS

\F

OR

ES

T

SE

RV

IC

E\

NF

S-

CT

B.

DW

G;

CHECKEDDESIGNERDATE

DRAWING TITLE

United States Department of Agriculture Forest Service

NO. DATEBYREVISION DESCRIPTION

DARBY/SULA RANGER DISTRICT

BITTERROOT NATIONAL FOREST

WARM SPRINGS WELL UPGRADE

NORTHERN REGION

R01 PUMP HOUSE

PLUMBING DETAIL

2/22/2023 JCAT SBOEL 6

S-2

NOTES:

* UV LIGHT SHALL HAVE A TRANSMITTANCE OF 95% UV LIGHT WITH A UV DOSE OF 40 mJ/cm^2

FOR FLOW RATES NO LESS THAN 14 GPM. THE LIGHT SHALL ALSO OPERATE AT120V AC AND

60 HZ. THE LIGHT SHALL ALSO NOT EXCEED 60 WATTS.

* PRESSURE RELIEF VALVE PIPE WILL BE INSTALLED TO OUTLET OUTSIDE THE PUMP HOUSE

AND SHALL POINT DOWN. THE OUTLET SHALL BE SCREENED.

WATER OUT

WATER IN

NORTH WALL OF PUMP HOUSE EAST WALL OF PUMP HOUSE

AutoCAD SHX Text M

AutoCAD SHX Text

PRESSURE RELIEF VALVE DETAIL

AutoCAD SHX Text

PROJECT NAME

AutoCAD SHX Text F

AutoCAD SHX Text O

AutoCAD SHX Text R

AutoCAD SHX Text E

AutoCAD SHX Text S

AutoCAD SHX Text T

AutoCAD SHX Text S

AutoCAD SHX Text E

AutoCAD SHX Text R

AutoCAD SHX Text V

AutoCAD SHX Text I

AutoCAD SHX Text C

AutoCAD SHX Text E

AutoCAD SHX Text D

AutoCAD SHX Text E

AutoCAD SHX Text P

AutoCAD SHX Text A

AutoCAD SHX Text R

AutoCAD SHX Text T

AutoCAD SHX Text M

AutoCAD SHX Text E

AutoCAD SHX Text N

AutoCAD SHX Text T

AutoCAD SHX Text O

AutoCAD SHX Text F

AutoCAD SHX Text A

AutoCAD SHX Text G

AutoCAD SHX Text R

AutoCAD SHX Text I

AutoCAD SHX Text C

AutoCAD SHX Text U

AutoCAD SHX Text L

AutoCAD SHX Text T

AutoCAD SHX Text U

AutoCAD SHX Text R

UNIMPROVED AREA ROADWAY SURFACE

SURFACE RESTORATION RESTORATION

NOTES:

1. USE PIPE BEDDING AS SPECIFIED BY C.O. FOR SOFT OR UNSTABLE

FOUNDATION.

2. BEDDING MATERIAL SHALL BE PLACED IN A THICKNESS EQUAL TO

X PIPE O.D.

BELOW THE PIPE (4 INCH MINIMUM) TO 6 INCHES ABOVE THE PIPE.

3. PIPE BEDDING SHALL BE CLEAN NON-COHESIVE, NATURAL UNWASHED GRAVEL,

SAND, OR CRUSHED HARD STONE GRADED AS FOLLOWS:

SIEVE SIZE PERCENT PASSING

1" 100

#4 40-70

#200 LESS THAN 10

4. THE WATER PIPE SHALL BE BURIED TO A DEPTH OF 5 FT FOR 20 FT OF LENGTH

AS SHOWN IN THE PITLESS ADAPTER DETAIL. THE DEPTH OF THE PIPE WILL

THEN TRANSITION TO A DEPTH OF 2 FT OVER 60 FT AS IT APPROACHES THE

PUMPHOUSE.

18"

NOTES:

1. WELL DEPTH IS 60' DEEP.

DWG SHEET NO.

OF

SHEET

9/2 8/1

8 0 7:

M

AR

KL

F

CA

D

ST

AN

DA

RD

S\

AG

EN

CY

S

TA

ND

AR

DS

\F

OR

ES

T

SE

RV

IC

E\

NF

S-

CT

B.

DW

G;

CHECKEDDESIGNERDATE

DRAWING TITLE

United States Department of Agriculture Forest Service

NO. DATEBYREVISION DESCRIPTION

DARBY/SULA RANGER DISTRICT

BITTERROOT NATIONAL FOREST

WARM SPRINGS WELL UPGRADE

NORTHERN REGION

R01 DETAILS

2/22/2023 JCAT SBOEL 7

D-1

M

I N

INSTALL CHECK VALVE AT

LEAST 40 FEET BELOW

GROUND LEVEL, NO MORE

THAN 25' ABOVE LOWEST

PUMPING LEVEL

INSTALL A GOULDS 10GS07

OR EQUIVALENT AT A DEPTH

OF 55 FEET FROM THE

SURFACE.

INSTALL BLEEDER VALVE,

CAMPBELL PART NO. BOB-3

OR EQUAL

INSTALL1-1/4" PITLESS

ADAPTER. CAMPBELL

B-20XLF OR EQUIVALENT

INSTALL 1-1/4" SCH. 80 PVC

THREADED DROP PIPE WITH

WIRE TAPED EVERY 20 FT.

INSTALL BRONZE BARBED

COMPRESSION COUPLING

TO HDPE PIPE

INSTALL 1-1/2" HDPE 3408,

DR11 PIPE

INSTALL SCHEDULE 80 PVC

CONDUIT THREADED INTO

WELL CAP TO A MINIMUM

DEPTH OF 2' TO ESTABLISH

DEPTH OF PUMP CONTROL

CABLE

INSTALL PUMP CONTROL

CABLE PER PUMP

MANUFACTURERS

SPECIFICATIONS

INSTALL VENTED, LOCKABLE,

WATERTIGHT WELL CAP, CAMPBELL

WTC6M, OR EQUAL. VENT SHALL BE

SCREENED.

INSTALL

" BRAIDED POLYPROPYLENE

SAFETY ROPE.

TRENCH DETAIL WELL DETAIL

AutoCAD SHX Text PIPE BEDDING PLACED IN 6" MAX. LAYERS AND COMPACTED AS SPECIFIED IN COMPACTION METHOD F.

AutoCAD SHX Text

MOUND TOP SOIL OVER TRENCH

AutoCAD SHX Text RESTORE ROAD SURFACE TO MATCH EXISTING, WITH MIN. 6" THICK CRUSHED BASE COURSE AND 6" SELECT SUBGRADE FILL

AutoCAD SHX Text

DETECTABLE WIRE TAPE AT 18" DEPTH

AutoCAD SHX Text

WARNING TAPE AT 12" DEPTH

AutoCAD SHX Text

SUBGRADE

AutoCAD SHX Text

PUMP CONTROL CABLE

AutoCAD SHX Text

DEPTH VARIES. SEE NOTE 4.

AutoCAD SHX Text

FROST DEPTH 42"

AutoCAD SHX Text

PROJECT NAME

AutoCAD SHX Text F

AutoCAD SHX Text O

AutoCAD SHX Text R

AutoCAD SHX Text E

AutoCAD SHX Text S

AutoCAD SHX Text T

AutoCAD SHX Text S

AutoCAD SHX Text E

AutoCAD SHX Text R

AutoCAD SHX Text V

AutoCAD SHX Text I

AutoCAD SHX Text C

AutoCAD SHX Text E

AutoCAD SHX Text D

AutoCAD SHX Text E

AutoCAD SHX Text P

AutoCAD SHX Text A

AutoCAD SHX Text R

AutoCAD SHX Text T

AutoCAD SHX Text M

AutoCAD SHX Text E

AutoCAD SHX Text N

AutoCAD SHX Text T

AutoCAD SHX Text O

AutoCAD SHX Text F

AutoCAD SHX Text A

AutoCAD SHX Text G

AutoCAD SHX Text R

AutoCAD SHX Text I

AutoCAD SHX Text C

AutoCAD SHX Text U

AutoCAD SHX Text L

AutoCAD SHX Text T

AutoCAD SHX Text U

AutoCAD SHX Text R

Sheets and Views
R01_Title-TITLE
Plan View WARM SPRINGS-EXISTING CONDITIONS
Plan View WARM SPRINGS-DEMOLITION PLAN
Plan View WARM SPRINGS-SITE PLAN
Structure & Plumbing plan View-PUMP HOUSE PLAN
Structure & Plumbing plan View-PUMP HOUSE PLUMBING DETAIL
Structure & Plumbing plan View-DETAILS
2023-05-30T08:52:10-0600
JUSTIN CATANACH
2023-06-01T14:59:12-0600
ABBIE JOSSIE
2023-05-30T15:06:35-0600
AMBER RICHARDSON
2023-06-01T16:14:29-0600
MATTHEW ANDERSON
2023-06-02T10:29:25-0600
DEBORAH DAVIS

File details come from the government source that posted it. Updated .