J.3.1 Maps Drawings UPDATED (3 Pages).pdf
PDF 2 MB Posted
- Attached to
- Kyle Canyon Bunkhouse HVAC Replacement
- Solicitation number
- 1240LT25Q0061
- Issued by
-
Department of Agriculture Forest Service
About this file
This document is a USDA Forest Service design and specifications file for the HVAC Replacement project at the Kyle Canyon Bunkhouse located in the Humboldt-Toiyabe National Forest, Spring Mountains National Recreation Area in Nevada. The project involves replacing the existing furnace system, including a 4-ton variable speed propane furnace with 88 MBH input heating capacity and an air-cooled condensing unit with 4 tons cooling capacity and an 18 SEER rating.
Key technical specifications include high-altitude conversion requirements (6,200 feet above sea level), installation of a new condensing unit concrete pad 24" off the roof eave, rerouting coolant lines, adding exterior room venting, and replacing furnace closet walls. The project requires installing refrigeration lines, modifying ductwork, and ensuring compatibility with site conditions. The contractor must use R-454B/R-32 refrigerant and provide 10-year compressor and 5-year parts warranties. The design emphasizes precise installation details, including specific requirements for refrigerant lines, venting, drainage, and electrical connections.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
ISOLATION VALVES
BUILDING WALL
COOLING COIL
(AT FURNACE)
S
UNIT DRAIN TRAPL
MOISTURE AND
LIQUID INDICATION
ALL REFRIGERANT LINES
TO BE ABOVE GROUND AND
SUPPORTED.
MECHANICALLY ANCHOR
UNIT TO BASE
PIPE DRAIN TO
FLOOR SINK
THERMAL EXPANSION
VALVE
SENSING BULB
1 NO SCALE
CONDENSING UNIT AND EVAPORATOR INSTALLATION DETAIL
FILTER/DRYER: MAY BE INTERGRATED
IN CONDENSING UNIT
COIL PAN DRAIN
3/4"ø PVC PIPE DRAIN
LINE TO FLOOR DRAIN
PVC INTAKE
PVC VENT
COOLING COIL
FURNACE
PROVIDE 4" FILTER BOX
TRANSITION TO COIL
CONNECTION SIZE
CONCENTRIC TERMINATION
VENT KIT UP THRU ROOF
(MOUNT PER MANUFACTURER'S
RECOMMENDATIONS)
REFRIGERATION
PIPING W/ TXV VALVE
UNION
GAS RATED BALL VALVE
SUPPLY DUCT
P-TRAPS
2 NO SCALE
TYPICAL FURNACE INSTALLATION DETAIL
VARIABLE SPEED PROPANE FURNACE SCHEDULE
BASIS OF DESIGN TONS
EST. STATIC
PRESSURE."WC
1.7
GAS TYPE
PROPANE
INPUT HEATING
CAPACITY (MBH)
88 MBH
AFUE
80%
FILTER TYPE
4" THICK
MERV
DIRECTION
UPFLOW
NOTES:
1-STAGE CONSTANT TORQUE HORIZONTAL GAS FURNACE
PROVIDE AND INSTALL 4" FILTER HOUSING.
PROVIDE AND INSTALL COOLING COIL FOR 1600 CFM, LENNOX MODEL CX35-49C
MODIFY EXISTING DUCTWORK, DRAINS, ELECTRICAL, AND OTHER CONNECTIONS AS NECESSARY TO INSTALL PER
MANUFACTURERS REQUIREMENTS.
* ALL PERFORMANCE OF COMPLETE SYSTEM BASED ON ALTITUDE OF 6,2OO FT ABOVE SEA LEVEL
ELECTRICAL
MOPC
AMPS
VOLTS/ PHASE
115V/ 1
AIR COOLED CONDENSING UNIT SCHEDULE
MARK
AC-1
PROVIDE LINE SETS 38" L 58" S, TXV FILTER/DRIER AND SITE GLASS, CRANK CASE HEATER, LOW AMBIENT KIT AND COMPRESSOR HARD START KIT
10 YEAR COMPRESSOR WARRANTY AND 5 YEAR PARTS WARRANTY REQUIRED
REFRIGERANT
ML18XC2-048-230
BASIS OF DESIGN
R-410A
AHRI SEER
AHRI SEER TONS
WEIGHT
MCA
21.9
AMPS
ELECTRICAL
MOPC
AMPS 208-230/ 1
VOLTS/ PHASE SLP- DBA
INSTALLATION NOTES
1. LOCATION IS AT APPROXIMATELY 6,200 FEET ABOVE SEA LEVEL. CONTRACTOR IS RESPONSIBLE FOR INSTALLING
HIGH ALTITUDE CONVERSION KIT, WITH CONVERSION STICKER AFFIXED TO NAME PLATE. FOLLOW MANUFACTURE
INSTRUCTION FOR HIGH ALTITUDE CONVERSION.
2. CONTRACTOR IS RESPONSIBLE FOR INSTALLING CONVERSION KIT FOR LIQUID PROPANE FUEL USE.
3. UNIT SPECIFIED OR EQUAL MAY BE INSTALLED. TOTAL INSTALLED SYSTEM COOLING CAPACITY MUST BE NO LESS
THAN 48,000 BTU WITH A SYSTEM SEER RATING OF 16.
USE R-454B/R-32
DRAWN
DESIGNER
STAMPS, LOGOS, AND SEALS
PROJECT NAME
DRAWING TITLE
CHECKED
ARCHIVE NO.DATE
PROJECT NO.
DRAWING SHEET NO.
DATENO.
REVISION / ISSUE
OFSHEET
United States Department of Agriculture Forest Service
/2/
:0 9 D
AK
OT
AK
RI
ST
C
:\U
SE
RS
\D
AK
OT
AK
RI
ST
\B
OX
\E
NG
DE
SI
GN
\H
UM
BO
LD
TT
OI
YA
BE
\R
MM
CJ
.S
MN
RA
.B
UN
KH
OU
SE
.H
VA
C.
\D
RA
W
IN
GS
\S
MN
RA
K
YL
E
BU
NK
HO
US
E
HV
AC
.D W
G;
R4
INTERMOUNTAIN REGION
HVAC
REPLACEMENT
HUMBOLDT-TOIYABE
NATIONAL FOREST
SPRING MOUNTAINS NATIONAL
RECREATION AREA
MECHANICAL DETAILS
04/16/2025
D. KRIST
D. KRIST
K. WILMOT
D-01 2 3
BASIS OF DESIGN 10/02/2025
ALTERATIONS TO BASIS OF DESIGN WILL BE CONSIDERED WITH APPROVED MANUFACTURES LISTED IN THE SPECIFICATION. SIMILAR SIZING PARAMETERS SHOULD BE USED OR JUSTIFIED IF DIFFERING FROM BASIS OF DESIGN SIZE. ALTERNATE REFRIGERANT R-454B AND R-32 SHOULD BE USED RATHER THAN R-410A.
SIZING OF REFRIGERANT LINES MUST MEET EQUIPMENT MANUFACTURER REQUIREMENTS.
AutoCAD SHX Text Lennox Merit ML180E, ML180UH090E60C
AutoCAD SHX Text F
AutoCAD SHX Text O
AutoCAD SHX Text R
AutoCAD SHX Text E
AutoCAD SHX Text S
AutoCAD SHX Text T
AutoCAD SHX Text S
AutoCAD SHX Text E
AutoCAD SHX Text R
AutoCAD SHX Text V
AutoCAD SHX Text I
AutoCAD SHX Text C
AutoCAD SHX Text E
AutoCAD SHX Text D
AutoCAD SHX Text E
AutoCAD SHX Text P
AutoCAD SHX Text A
AutoCAD SHX Text R
AutoCAD SHX Text T
AutoCAD SHX Text M
AutoCAD SHX Text E
AutoCAD SHX Text N
AutoCAD SHX Text T
AutoCAD SHX Text O
AutoCAD SHX Text F
AutoCAD SHX Text A
AutoCAD SHX Text G
AutoCAD SHX Text R
AutoCAD SHX Text I
AutoCAD SHX Text C
AutoCAD SHX Text U
AutoCAD SHX Text L
AutoCAD SHX Text T
AutoCAD SHX Text U
AutoCAD SHX Text R
AutoCAD SHX Text E
DRAWN
DESIGNER
STAMPS, LOGOS, AND SEALS
PROJECT NAME
DRAWING TITLE
CHECKED
ARCHIVE NO.DATE
PROJECT NO.
DRAWING SHEET NO.
DATENO.
REVISION / ISSUE
OFSHEET
United States Department of Agriculture Forest Service
/2/
:0 9 D
AK
OT
AK
RI
ST
C
:\U
SE
RS
\D
AK
OT
AK
RI
ST
\B
OX
\E
NG
DE
SI
GN
\H
UM
BO
LD
TT
OI
YA
BE
\R
MM
CJ
.S
MN
RA
.B
UN
KH
OU
SE
.H
VA
C.
\D
RA
W
IN
GS
\S
MN
RA
K
YL
E
BU
NK
HO
US
E
HV
AC
.D W
G;
R4
INTERMOUNTAIN REGION
KYLE CANYON
BUNKHOUSE
HVAC
REPLACEMENT
HUMBOLDT-TOIYABE
NATIONAL FOREST
SPRING MOUNTAINS NATIONAL
RECREATION AREA
MECHANICAL DETAILS
04/16/2025
D. KRIST
D. KRIST
K. WILMOT
D-02 3 3
ROOM VENTING CLARIFICATION
CLOSET WALLS
CLOSET WALLS 10/02/2025
10/02/2025
10/02/2025
OUTDOOR UNIT TO BE
REPLACED. CONCRETE PAD
TO BE MOVED 24" OFF OF
ROOF EAVE.
PROPANE TANK
REROUTE COOLANT LINE PENETRATION. ADD EXTERIOR
VENT AT TOP OF ROOM FOR COMBUSTION AIRFLOW.
EXISTING
FURNACE AND
COOLING COIL
NOTES
1. REPLACE AND APPROPRIATELY DISPOSE OF EXISTING FURNACE SYSTEM.
2. REMOVE, REPLACE AND DISPOSE OF WALLS OF FURNACE CLOSET. DOOR AND DOOR HARDWARE ARE
TO BE RETURNED TO THE DISTRICT OR REUSED FOR PROJECT.
3. CONTRACTOR IS RESPONSIBLE FOR MODIFICATION TO CONDENSING UNIT PAD SIZE, IF REQUIRED.
EXISTING PAD MAY BE REUSED OR DISPOSED OF. PAD MUST BE PLACED 24" OFFSET OF ROOF EAVES.
4. ALL VENT AND DRAIN LINES SHOULD BE REPLACED WITH PENETRATIONS CHECKED FOR ACCEPTABLE
EXTERIOR SEAL. COMBUSTION AND EXHAUST AIR MUST BE OUTSIDE AIR. ADD VENT 12" FROM TOP OF
ROOM. VENTING IS TO BE WEATHER PROTECTED AND SCREENED.
5. COOLANT PENETRATION LINE SHOULD BE REROUTED OUT OF VENT AND THROUGH EXTERIOR WALL OR
CRAWLSPACE.
6. ALL REMOVABLE ITEMS WILL BE RELOCATED FROM THE FURNACE CLOSET AREA FOR THE DURATION OF
INSTALLATION.
REMOVE AND REPLACE
FURNACE CLOSET WALLS
1 CLARIFICATION- ADD ROOM VENTING IN ADDITION TO FURNACE-REQUIRED VENTING IMMEDIATELY ABOVE FURNACE. ROOM VENT FIXTURE MUST BE INTENDED FOR EXTERIOR VENT USE AND MEET MINIMUM SIZE REQUIREMENTS.
AutoCAD SHX Text F
AutoCAD SHX Text O
AutoCAD SHX Text R
AutoCAD SHX Text E
AutoCAD SHX Text S
AutoCAD SHX Text T
AutoCAD SHX Text S
AutoCAD SHX Text E
AutoCAD SHX Text R
AutoCAD SHX Text V
AutoCAD SHX Text I
AutoCAD SHX Text C
AutoCAD SHX Text E
AutoCAD SHX Text D
AutoCAD SHX Text E
AutoCAD SHX Text P
AutoCAD SHX Text A
AutoCAD SHX Text R
AutoCAD SHX Text T
AutoCAD SHX Text M
AutoCAD SHX Text E
AutoCAD SHX Text N
AutoCAD SHX Text T
AutoCAD SHX Text O
AutoCAD SHX Text F
AutoCAD SHX Text A
AutoCAD SHX Text G
AutoCAD SHX Text R
AutoCAD SHX Text I
AutoCAD SHX Text C
AutoCAD SHX Text U
AutoCAD SHX Text L
AutoCAD SHX Text T
AutoCAD SHX Text U
AutoCAD SHX Text R
AutoCAD SHX Text E
| SMNRA Kyle Bunkhouse HVAC_02OCT2025.pdf |
| Sheets and Views |
| SMNRA Kyle Bunkhouse HVAC-COVER |
| OLE1 |
| SMNRA Kyle Bunkhouse HVAC-DETAILS |
| OLE1 |
| SMNRA Kyle Bunkhouse HVAC-LOCATION DETAILS |
| OLE1 |
File details come from the government source that posted it. Updated .