RomtecSSTVaultModel1002.pdf

PDF 664 KB Posted

Attached to
KLAHANIE VAULT TOILET AND WELL REMOVAL. OLYMPIC NATIONAL FOREST
Solicitation number
1240BD26Q0070
Issued by

About this file

This document is an installation manual and technical drawing set for a prefabricated restroom building manufactured by ROMTEC, Inc.

The structure is a 12'-0" x 22'-0" traditional single-occupancy restroom facility with a 750-gallon vault system. Key components include a polyethylene building with wood exterior panels stained brown, four 4x4 cedar tone wood posts, architectural composite roofing, two polycarbonate windows (pre-installed), stainless steel grab bars, a polyethylene toilet riser with seat and lid, 12" ID polyethylene vent pipe with black cover, and a kick-resistant wall vent. The building requires a minimum 12'-0" x 22'-0" concrete pad prepared by the contractor and must be positioned with proper ventilation orientation, with the black vent pipe facing south for optimal solar heating and ventilation. Installation specifications include site selection requirements to ensure unobstructed airflow across the vent pipe top, proper drainage (4-6" depth minimum), and positioning away from overhangs, dense vegetation, or ridge lines. The structure utilizes WETSET USP WAS44 post anchors and includes field-installed components such as the kick-resistant wall vent. All plans and drawings are protected intellectual property of ROMTEC, Inc., located in Roseburg, Oregon, and cannot be reproduced or used for construction without written permission.

View the file

Other files

File Type Posted
HandPumpTyppical.pdf PDF
MAP.pdf PDF
Amendment 001 1240BD26Q0070.pdf PDF
KlahanieWellReport.pdf PDF
Solicitation 1240BD26Q0070 Klahanie Vault.pdf PDF

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

INSTALL

INSTRUCTIONS

JOB CREATED: 4/14/2022 - LAST SAVED BY: zanderson ON 4/14/2022 - LAST PRINTED: 12/17/2020 - LOCATION: O:\Engineering RI\Sales Drawings\Templates\Trads - 1002-1009\Install Manuals\TRAD_CAD\1002 - 1004 - SST Traditional Single RR 220414.dwg

XX/XX/XXXX

XXXXX

DRAWN BY:

SHEET NO.

PLAN SET#

DATE:

P R

O

JE

C T

S H

E E

T T

IT

LE

REV. DATE: BY

REVISIONS

ZA

0 N

OR

TH

B

AN

K

RO

AD

RO

SE

BU

RG

, O R

(5

)-4

-3

F

AX

(5

)-4

-0

R

O M

T E C

IN

C A

L L R

IG

H T S R

E S E R

V E D

T

H E S E P

L A N S A

N D

D R

A W

IN

G

S M

A Y N

O T B

E R

E P R

O D

UC

E D

A D

A P T E D

O R

F

UR

T H E R

D

IS

T R

IB

UT

E D

A N D

N O

B

UI

L D

IN

G

S M

A Y B

E C

O N S T R

UC

T E D

F R

O M

T H E S E P

L A N S W

IT

H O

UT

T

H E W

R

IT

T E N P

E R

M

IS

S

IO

N O

F R

O M

T E C

IN

C

C

X X X

X X X

F L O

O R

P L A N

A1.1

KICK VENT INSTALLATION NOTES:

1. LOCATE VENT UNDER WINDOW ON PREVAILING

WIND SIDE OF BUILDING, DO NOT INSTALL THE

VENT ON BACK OF BUILDING OR DOOR.

2. TO INSTALL WALL VENT CUT HOLE IN THE WALL

THE SIZE OF THE VENT, THEN MOUNT THE VENT IN

THE WALL WITH PROVIDED FASTENERS

(6) 1/4"-20UNC x 1-1/4" BOLTS WITH SPRING NUT.

3. LOUVERS ARE TO BE POINTED DOWN.

4. DO NOT INSTALL ANY OTHER VENTS, THIS WILL

DEFEAT THE SPECIFIED VENTILATION SYSTEM.

BUILDING LOCATION INSTALLATION NOTES:

1. TO PROVIDE PROPER VENTILATION, THE

BUILDING IS TO BE ORIENTED WITH THE BLACK

VENT SHROUD IN THE BACK FACING SOUTH.

SOLAR HEAT INSIDE THE BLACK VENT SHROUD

IMPROVES VENTILATION.

2. SELECT A SITE THAT PROVIDES AN

UNOBSTRUCTED AIR FLOW ACROSS THE TOP OF

THE 12" VENT PIPE.

3. DO NOT LOCATE BUILDING IN A HOLLOW,

BENEATH AN OVER HANG, ON LEE SIDE OF A

RIDGE, IMMEDIATELY ADJACENT TO A DENSE

TREE LINE, OR IN DENSE BRUSH OR TREES.

NOTE: BOTH BUILDING LOCATION AND

ORIENTATION ARE CRITICAL TO PROPER

VENTILATION OF BUILDING.

4. SITE SHOULD BE IN A WELL DRAINED AREA

THAT CAN BE EXCAVATED TO A DEPTH OF 4'-6"

AND GRADED LEVEL 12' x 22'

FLOOR PLAN

SCALE: 1/4" = 1'-0"

A

B

C

D

C A2.2

6'-11 11/16"

12'-0" SLAB OVERALL

1'-9 15/16" 6'-4 1/8" 3'-9 15/16"

7' -4

7' -8

7' -0

S L A B

O V

E R

A L L

/8

18"

7' -7

/4

P O

S T S

A A2.1

D A2.2

B A2.1

A3.1

6'-0 1/4" POSTS

750 GALLON VAULT

BLACK VENT PIPE COVER

(PRE-INSTALLED)

12" ID POLYETHYLENE VENT PIPE

POLYETHYLENE TOILET RISER

WITH SEAT & LID

STAINLESS STEEL GRAB BARS

POLYETHYLENE BUILDING

WITH WOOD EXTERIOR PANELS

4x4 CEDAR TONE WOOD POSTS, TYP (4)

ROOF OUTLINE (SHOWN FOR REF. ONLY)

SEE SHEET A7.1 FOR ROOF PLAN

12'-0" x 22'-0" MIN CONCRETE PAD

BY CONTRACTOR

POLYCARBONATE WINDOW,

PRE-INSTALLED TYP. (2)

XV-000-1017 KICK RESISTANT WALL VENT

INSTALLED ON-SITE

SEE INSTALLATION NOTES

B

ELEVATION VIEW

SCALE: 3/8" = 1'-0"A

ELEVATION VIEW

SCALE: 3/8" = 1'-0"

ARCHITECTURAL COMP ROOFING

INSTALL

INSTRUCTIONS

JOB CREATED: 4/14/2022 - LAST SAVED BY: zanderson ON 4/14/2022 - LAST PRINTED: 12/17/2020 - LOCATION: O:\Engineering RI\Sales Drawings\Templates\Trads - 1002-1009\Install Manuals\TRAD_CAD\1002 - 1004 - SST Traditional Single RR 220414.dwg

XX/XX/XXXX

XXXXX

DRAWN BY:

SHEET NO.

PLAN SET#

DATE:

P R

O

JE

C T

S H

E E

T T

IT

LE

REV. DATE: BY

REVISIONS

ZA

0 N

OR

TH

B

AN

K

RO

AD

RO

SE

BU

RG

, O R

(5

)-4

-3

F

AX

(5

)-4

-0

R

O M

T E C

IN

C A

L L R

IG

H T S R

E S E R

V E D

T

H E S E P

L A N S A

N D

D R

A W

IN

G

S M

A Y N

O T B

E R

E P R

O D

UC

E D

A D

A P T E D

O R

F

UR

T H E R

D

IS

T R

IB

UT

E D

A N D

N O

B

UI

L D

IN

G

S M

A Y B

E C

O N S T R

UC

T E D

F R

O M

T H E S E P

L A N S W

IT

H O

UT

T

H E W

R

IT

T E N P

E R

M

IS

S

IO

N O

F R

O M

T E C

IN

C

C

X X X

X X X

E L E V

A T

IO

N S

A2.1

SIDING STAINED

BROWN BY ROMTEC

WETSET USP WAS44

POST ANCHOR, TYP (4)

A7.2

ROOFING

DETAIL

A7.2

ROOFING

DETAIL

A7.2

ROOFING

DETAIL

4x4 PT WOOD POST

CEDARTONE, TYP (4)

POLY PIPE W/ BUG

SCREEN, DETAIL 2/A3.2

POLY PIPE W/ BUG

SCREEN, DETAIL 2/A3.2

1x4 CEDAR TRIM

2x4 DF FASCIA

2x4 DF FASCIA

POLYCARBONATE WINDOW

(PRE INSTALLED)

1/2"x6" BEVEL CEDAR

4x4 PT WOOD POST

CEDARTONE, TYP (4)

VENT PIPE COVER

1/2"x6" BEVEL CEDAR

VENT PIPE

COVER

SIDING PANELS FACTORY INSTALLED

mcarmstrong Highlight

/1

"9' -7

/1

A .F

.F

F.F.

C

ELEVATION VIEW

SCALE: 3/8" = 1'-0" D

ELEVATION VIEW

SCALE: 3/8" = 1'-0"

ARCHITECTURAL COMP ROOFING

INSTALL

INSTRUCTIONS

JOB CREATED: 4/14/2022 - LAST SAVED BY: zanderson ON 4/14/2022 - LAST PRINTED: 12/17/2020 - LOCATION: O:\Engineering RI\Sales Drawings\Templates\Trads - 1002-1009\Install Manuals\TRAD_CAD\1002 - 1004 - SST Traditional Single RR 220414.dwg

XX/XX/XXXX

XXXXX

DRAWN BY:

SHEET NO.

PLAN SET#

DATE:

P R

O

JE

C T

S H

E E

T T

IT

LE

REV. DATE: BY

REVISIONS

ZA

0 N

OR

TH

B

AN

K

RO

AD

RO

SE

BU

RG

, O R

(5

)-4

-3

F

AX

(5

)-4

-0

R

O M

T E C

IN

C A

L L R

IG

H T S R

E S E R

V E D

T

H E S E P

L A N S A

N D

D R

A W

IN

G

S M

A Y N

O T B

E R

E P R

O D

UC

E D

A D

A P T E D

O R

F

UR

T H E R

D

IS

T R

IB

UT

E D

A N D

N O

B

UI

L D

IN

G

S M

A Y B

E C

O N S T R

UC

T E D

F R

O M

T H E S E P

L A N S W

IT

H O

UT

T

H E W

R

IT

T E N P

E R

M

IS

S

IO

N O

F R

O M

T E C

IN

C

C

X X X

X X X

E L E V

A T

IO

N S

A2.2

SIDING STAINED

BROWN BY ROMTEC

WETSET USP WAS44

POST ANCHOR, TYP (4)

A7.2

ROOFING

DETAIL

A7.2

ROOFING

DETAIL

A7.2

ROOFING

DETAIL

POLY PIPE W/ BUG

SCREEN, DETAIL 2/A3.2

POLY PIPE W/ BUG

SCREEN, DETAIL 2/A3.2

WETSET USP WAS44

POST ANCHOR, TYP (4)

4x4 PT WOOD POST

CEDARTONE, TYP (4)

VENT PIPE

COVER

3'0 x 6'8 STEEL DOOR

2x4 DF FASCIA

2x4 DF FASCIA

POLYCARBONATE WINDOW

(PRE INSTALLED)

4x4 PT WOOD POST

CEDARTONE, TYP (4)

KICK RESISTANT

WALL VENT

(FIELD INSTALLED

NOTES SHEET A1.1)

Sheets and Views
1002 - 1005 - SST Traditional Single RR -220926-A2.1-2
1002 - 1005 - SST Traditional Single RR -220926-A3.1-2
1002 - 1005 - SST Traditional Single RR -220926-A3.2-2

File details come from the government source that posted it. Updated .