Amendment 09- Mayaguez Site Plan Sheet E100 and Sheet E200 Electrical One Line.pdf

PDF 489 KB Posted

Attached to
Mayaquez Underground Electrical Distribution Federal contract opportunity
Solicitation number
12405B21R0002
Issued by
Department of Agriculture Agricultural Research Service Field Research Implementation and Information Delivery

About this file

This solicitation is for an underground electrical distribution system installation at the USDA Agricultural Research Service Tropical Agriculture Research Station in Mayaguez, Puerto Rico. The NAICS code for this small business set-aside contract is 238210. Interested contractors must attend a scheduled site visit to discuss the required scope of work detailed in the attached drawings and specifications. This includes all necessary equipment, labor, materials and transportation to provide the underground electrical distribution to serve identified buildings on site. Proposals must be submitted to the Contracting Officer at the specified email address by the deadline to be considered.

View the file

Other files for this federal contract opportunity

Other files attached to Mayaquez Underground Electrical Distribution, newest first.
File Type Posted
12405B21R0002-AMENDMENT 12 signed.pdf PDF
12405B21R0002-AMENDMENT 11-SF1442 Corrections signed.pdf PDF
12405B21R0002-AMENDMENT 10 SIGNED.pdf PDF
Amendment 10- Questions and Answers Solicitation 12405B21R0002.pdf PDF
Amendment 10- DRAWING E101R1_E200R2 (002).pdf PDF
Amendment 09- Questions and Answers.pdf PDF
Amendment 09- Section 26 12 19- Change 1.pdf PDF
12405B21R0002 - Amendment 09 signed.pdf PDF
Amendment 09- SURVEY MAYA.pdf PDF
Amendment 09 -Site Visit Notice Mayaguez Underground Electrical Distribution.pdf PDF
Amendment 09- Section 26 12 21- Change 2.pdf PDF
Sol 12405B21R0002 Amd 0008.pdf PDF
Sol 12405B21R0002 Amd 0007.pdf PDF
Sol 12405B21R0002 Amd 0006.pdf PDF
Sol 12405B21R0002 Amd 0005.pdf PDF
Sol 12405B21R0002 Amd 0004.pdf PDF
Sol 12405B21R0002 Mod 3 Ext of Proposal Due Date.pdf PDF
Solicitation12405B21R0002 Amendment 2.pdf PDF
Solicitation 12405B21R0002 Mayaguez Underground Amendment 1.pdf PDF
Site Visit Notice - Mayaguez Underground Electrical Distribution.pdf PDF
Solicitation 12405B21R0002 NOTICE.pdf PDF
SF 1442 Solicitation 12405B21R0002.pdf PDF
Mayaguez Underground Power Specifications.pdf PDF
ARS372.pdf PDF
Solicitation 12405B21R0002-Including Clauses - Provisions.pdf PDF
Drawings-Mayaguez Underground Power Construction.pdf PDF
ARS371.pdf PDF
Show all 27

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

KEYED NEW WORK NOTES

GENERAL NOTES

LEGEND

AutoCAD SHX Text

GATE

AutoCAD SHX Text

GATE

AutoCAD SHX Text

ASPHALTED ROAD

AutoCAD SHX Text B25

AutoCAD SHX Text B24

AutoCAD SHX Text

ASPHALTED ROAD

AutoCAD SHX Text

CONCRETE ROAD

AutoCAD SHX Text

ASPHALTED ROAD

AutoCAD SHX Text B13

AutoCAD SHX Text B17

AutoCAD SHX Text B16

AutoCAD SHX Text B28

AutoCAD SHX Text B18

AutoCAD SHX Text B20

AutoCAD SHX Text B23

AutoCAD SHX Text B22

AutoCAD SHX Text

CONCRETE ROAD

AutoCAD SHX Text

CONCRETE ROAD

AutoCAD SHX Text

CONCRETE ROAD

AutoCAD SHX Text B19

AutoCAD SHX Text

CONCRETE ROAD

AutoCAD SHX Text B11

AutoCAD SHX Text B41

AutoCAD SHX Text B42

AutoCAD SHX Text B43

AutoCAD SHX Text

GREEN HOUSE

AutoCAD SHX Text B44

AutoCAD SHX Text B45

AutoCAD SHX Text

GREEN HOUSE

AutoCAD SHX Text B7

AutoCAD SHX Text B6

AutoCAD SHX Text

ASPHALTED ROAD

AutoCAD SHX Text B5

AutoCAD SHX Text B48

AutoCAD SHX Text B32

AutoCAD SHX Text B33

AutoCAD SHX Text B34

AutoCAD SHX Text B46

AutoCAD SHX Text B37

AutoCAD SHX Text

ASPHALTED ROAD

AutoCAD SHX Text

GREEN HOUSE AREA

AutoCAD SHX Text S/W

AutoCAD SHX Text

ASPHALTED ROAD

AutoCAD SHX Text

STATE ROAD NO. 108

AutoCAD SHX Text

STATE ROAD NO. 108

AutoCAD SHX Text

STATE ROAD NO. 108

AutoCAD SHX Text X2-1

AutoCAD SHX Text

AutoCAD SHX Text X2-2

AutoCAD SHX Text X2-3

AutoCAD SHX Text X2-4

AutoCAD SHX Text X3-1

AutoCAD SHX Text G-1

AutoCAD SHX Text S2

AutoCAD SHX Text

PREPA SERVICE 4160V

AutoCAD SHX Text S3

AutoCAD SHX Text S1

AutoCAD SHX Text X3-2

AutoCAD SHX Text

ATS3-2

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text B26

AutoCAD SHX Text

ASPHALTED ROAD

AutoCAD SHX Text S4

AutoCAD SHX Text X4-1

AutoCAD SHX Text

GEN 4

AutoCAD SHX Text X4-2

AutoCAD SHX Text

ATS4-1

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

GEN 3

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text 1 PROVIDE NEW CONCRETE EQUIPMENT PAD. REFER TO PROVIDE NEW CONCRETE EQUIPMENT PAD. REFER TO E500 DETAIL 2. 2 DEMOLISH EXISTING PAD AND PROVIDE NEW EQUIPMENT DEMOLISH EXISTING PAD AND PROVIDE NEW EQUIPMENT PAD. 3 PROVIDE OPEN STRUCTURE WITH METAL ROOF TO PROVIDE OPEN STRUCTURE WITH METAL ROOF TO PROTECT EQUIPMENT FROM ELEMENTS. REFER TO E500 DETAILS 1 AND 3 4 EXISTING SOIL DRYER ON SLAB BESIDE BUILDING B6. EXISTING SOIL DRYER ON SLAB BESIDE BUILDING B6. DEMOLISH EXISTING SOIL DRYER. ASSUME ASBESTOS INSULATION IN LINER. REPAIR SLAB, REMOVE GENERATOR AND TANK FROM TRAILER AND INSTALL GENERATOR ON SLAB. 5 REFEED EXISTING METER BASE. REFEED EXISTING METER BASE. 6 REFEED EXISTING METER BASE/PANEL. REFEED EXISTING METER BASE/PANEL. 7 INSTALL METER BASE FOR PREPA METERING. INSTALL METER BASE FOR PREPA METERING.

AutoCAD SHX Text A. DIRECTIONAL BORING WILL BE USED FOR ALL PRIMARY DIRECTIONAL BORING WILL BE USED FOR ALL PRIMARY AND SECONDARY DISTRIBUTION SERVICES TO MINIMIZE THE IMPACT ON SITE LANDSCAPING. ANY DAMAGE TO LANDSCAPING OR ROADWAYS ARE REQUIRED TO BE RETURNED TO AS-FOUND CONDITION AT TERMINATION OF WORK. B. CONTRACTOR RESPONSIBLE FOR REMOVAL AND CONTRACTOR RESPONSIBLE FOR REMOVAL AND DISPOSAL OF DEMOLITION WORK FROM SITE. C. HAND HOLES WILL BE INSTALLED ALONG CONDUIT PATHS HAND HOLES WILL BE INSTALLED ALONG CONDUIT PATHS AT A MINIMUM OF 400' INTERVALS. D. DEMOLISH SECONDARY SERVICE FOR SITE LIGHTING. DEMOLISH SECONDARY SERVICE FOR SITE LIGHTING. TRENCH AND REFEED SECONDARY SERVICE FOR SITE LIGHTING UNDERGROUND IN SCHEDULE 40 PVC CONDUIT BURIED MINIMUM 24" BELOW GRADE. CONTRACTOR SHALL USE RIGID METAL CONDUIT WHEN EXPOSED ON POLE UP TO 10' OR WITHIN 24" OF GRADE. SEAL POLE RISER WITH WEATHERHEAD AND CONNECT TO EXISTING POLE MOUNTED LIGHTS. E. DEMOLISH AND DISPOSE OF ALL OVERHEAD DEMOLISH AND DISPOSE OF ALL OVERHEAD CONDUCTORS AND OVERHEAD SERVICE ENTRANCES. REPAIR ROOF PENETRATIONS. DEMOLISH ALL POLES EXCEPT THOSE CONTAINING SITE LIGHTING. CUT POLE 1' ABOVE LIGHT FIXTURE. RE-SERVE FIXTURE FROM UNDERGROUND SITE LIGHTING SERVICE. ENCLOSE CONDUCTOR IN RIGID METAL CONDUIT ON POLE UNTIL 10' ABOVE GRADE. F. PREPA SERVICE TERMINATES AT CONCRETE POLE AT PREPA SERVICE TERMINATES AT CONCRETE POLE AT FACILITY PERIMETER IDENTIFIED BY KEYNOTE 7. ALL OTHER SITE DISTRIBUTION IS PROPERTY OF THE FEDERAL GOVERNMENT.

AutoCAD SHX Text

PRIMARY - 4160V 3-PHASE

AutoCAD SHX Text

SECONDARY - 208V/120V 3-PHASE

AutoCAD SHX Text

EQUIPMENT SCHEDULE

AutoCAD SHX Text

INDEX

AutoCAD SHX Text

TYPE

AutoCAD SHX Text

DESCRIPTION

AutoCAD SHX Text

BASIS OF DESIGN

AutoCAD SHX Text S1

AutoCAD SHX Text

NEW

AutoCAD SHX Text

PAD MOUNTED FUSED SWITCH

AutoCAD SHX Text

EATON MOST/MODEL 3

AutoCAD SHX Text S2

AutoCAD SHX Text

NEW

AutoCAD SHX Text

PAD MOUNTED OIL FILLED SWITCH

AutoCAD SHX Text

EATON MOST/MODEL 9B

AutoCAD SHX Text S3

AutoCAD SHX Text

NEW

AutoCAD SHX Text

PAD MOUNTED OIL FILLED SWITCH

AutoCAD SHX Text

EATON MOST/MODEL 9B

AutoCAD SHX Text S4

AutoCAD SHX Text

NEW

AutoCAD SHX Text

PAD MOUNTED OIL FILLED SWITCH

AutoCAD SHX Text

EATON MOST/MODEL 9B

AutoCAD SHX Text

GEN 1

AutoCAD SHX Text

EXISTING

AutoCAD SHX Text

PAD MOUNTED GENERATOR

AutoCAD SHX Text

RAJYSAN/RDG150-SV1

AutoCAD SHX Text

GEN 3

AutoCAD SHX Text

EXISTING

AutoCAD SHX Text

TRAILER MOUNTED GENERATOR

AutoCAD SHX Text

HIPOWER/HR145

AutoCAD SHX Text

GEN 4

AutoCAD SHX Text

NEW

AutoCAD SHX Text

PAD MOUNTED GENERATOR

AutoCAD SHX Text

CUMMINS/C125 D6C

AutoCAD SHX Text X2-1

AutoCAD SHX Text

NEW

AutoCAD SHX Text

PAD MOUNTED OIL FILLED TRANSFORMER

AutoCAD SHX Text

EATON/50KVA SINGLE PHASE 240/120V

AutoCAD SHX Text X2-2

AutoCAD SHX Text

NEW

AutoCAD SHX Text

PAD MOUNTED OIL FILLED TRANSFORMER

AutoCAD SHX Text

EATON/50KVA SINGLE PHASE 240/120V

AutoCAD SHX Text X2-3

AutoCAD SHX Text

NEW

AutoCAD SHX Text

PAD MOUNTED OIL FILLED TRANSFORMER

AutoCAD SHX Text

EATON/50KVA SINGLE PHASE 240/120V

AutoCAD SHX Text X2-4

AutoCAD SHX Text

NEW

AutoCAD SHX Text

PAD MOUNTED OIL FILLED TRANSFORMER

AutoCAD SHX Text

EATON/50KVA 208/120V THREE PHASE

AutoCAD SHX Text X3-1

AutoCAD SHX Text

NEW

AutoCAD SHX Text

PAD MOUNTED LFF FILLED TRANSFORMER

AutoCAD SHX Text

EATON/150KVA 208/120V THREE PHASE

AutoCAD SHX Text X3-2

AutoCAD SHX Text

NEW

AutoCAD SHX Text

PAD MOUNTED OIL FILLED TRANSFORMER

AutoCAD SHX Text

EATON/75KVA 208/120V THREE PHASE

AutoCAD SHX Text X4-1

AutoCAD SHX Text

NEW

AutoCAD SHX Text

PAD MOUNTED OIL FILLED TRANSFORMER

AutoCAD SHX Text

EATON/150KVA 208/120V THREE PHASE

AutoCAD SHX Text X4-2

AutoCAD SHX Text

NEW

AutoCAD SHX Text

PAD MOUNTED OIL FILLED TRANSFORMER

AutoCAD SHX Text

EATON/50KVA SINGLE PHASE 240/120V

AutoCAD SHX Text

ATS3-2

AutoCAD SHX Text

NEW

AutoCAD SHX Text

NEMA 3R 600A TRANSFER SWITCH

AutoCAD SHX Text

EATON 600A 4-POLE ATS

AutoCAD SHX Text

ATS4-1

AutoCAD SHX Text

NEW

AutoCAD SHX Text

NEMA 3R 600A TRANSFER SWITCH

AutoCAD SHX Text

EATON 600A 4-POLE ATS

AutoCAD SHX Text

SCALE: 1/64" = 1'-0"

AutoCAD SHX Text 192'

AutoCAD SHX Text 16'

AutoCAD SHX Text 64'

AutoCAD SHX Text 128'

AutoCAD SHX Text

AutoCAD SHX Text

SCALE:

AutoCAD SHX Text

SITE PLAN

AutoCAD SHX Text 1/64" = 1'-0"

AutoCAD SHX Text

AutoCAD SHX Text E100

AutoCAD SHX Text

PPM

AutoCAD SHX Text

REVISIONS

AutoCAD SHX Text

DESCRIPTION

AutoCAD SHX Text

SHEET

AutoCAD SHX Text

DATE

AutoCAD SHX Text c

AutoCAD SHX Text P.A.

AutoCAD SHX Text

FIRM

AutoCAD SHX Text U

AutoCAD SHX Text

NO.

AutoCAD SHX Text D

AutoCAD SHX Text

EPM

AutoCAD SHX Text

SAFETY & HEALTH

AutoCAD SHX Text

REAL PROPERTY

AutoCAD SHX Text A

AutoCAD SHX Text

DATE

AutoCAD SHX Text

PROJECT NO.

AutoCAD SHX Text S

AutoCAD SHX Text

USDA

AutoCAD SHX Text

BY

AutoCAD SHX Text

AGRICULTURAL RESEARCH SERVICE

AutoCAD SHX Text

OF

AutoCAD SHX Text

THE

AutoCAD SHX Text

DESIGNER

AutoCAD SHX Text

PROJECT MANAGER

AutoCAD SHX Text

JOB #

AutoCAD SHX Text

CHECKED BY

AutoCAD SHX Text

A-E FIRM

AutoCAD SHX Text

P.O. BOX 513, GREENWOOD, MISSISSIPPI - (662) 455-4943

AutoCAD SHX Text Johnson M Adams

AutoCAD SHX Text

ARCHITECTS/ENGINEERS PLANNING SURVEYING MANAGEMENT

AutoCAD SHX Text Agricultural

AutoCAD SHX Text Service

AutoCAD SHX Text Research

AutoCAD SHX Text

USDA AGRICULTURAL RESEARCH SERVICE

AutoCAD SHX Text

TROPICAL AGRICULTURAL RESEARCH STATION

AutoCAD SHX Text

MAYAGUEZ, PUERTO RICO

AutoCAD SHX Text

UNDERGROUND ELECTRICAL DISTRIBUTION

AutoCAD SHX Text

SITE PLAN

AutoCAD SHX Text E100

AutoCAD SHX Text 35 39

AutoCAD SHX Text 7/24/20

AutoCAD SHX Text

BSN

AutoCAD SHX Text

BSN

AutoCAD SHX Text

DRL

AutoCAD SHX Text

MID SOUTH AREA

AutoCAD SHX Text

STONEVILLE, MS

AutoCAD SHX Text 2719-E

AutoCAD SHX Text

STATE ROAD NO. 108

AutoCAD SHX Text SUMMARY OF WORK: UTILITY SERVICE FROM PUERTO RICO ELECTRIC POWER AUTHORITY ENTERS THE SITE BY OVERHEAD TRANSMISSION LINES TERMINATING AT A POLE MOUNTED SWITCH. CONTRACTOR IS TO DEMOLISH THE OVERHEAD ELECTRICAL DISTRIBUTION IN FULL, STARTING AT THE SWITCH AND ENDING AT EACH BUILDING POINT OF CONNECTION, TYPICALLY A PANEL OR METER BASE. CONTRACTOR SHALL PROVIDE CONDUIT AND CONDUCTORS FROM PREPA SWITCH TO S1. CONTRACTOR SHALL PROVIDE AN ELECTRICAL DISTRIBUTION SYSTEM IN FULL INCLUDING EQUIPMENT, CONDUCTORS, CONDUIT AS REQUIRED TO SERVE BUILDINGS SHOWN BELOW. CONTRACTOR SHALL DEMOLISH THE OVERHEAD COMMUNICATIONS CABLING AND RE-SERVE COMMUNICATION LOADS (COPPER AND FIBER) THROUGH UNDERGROUND SERVICE. COPPER SERVICE ENTERS THE FACILITY BY OVERHEAD TRANSMISSION NEAR SWITCH 'S2' AND FEEDS THE BUILDINGS AS LISTED ON E101. FIBER OPTIC DISTRIBUTION ORIGINATES AT BUILDING 1 AND IS DISTRIBUTED ACROSS THE CAMPUS BY OVERHEAD DISTRIBUTION. CONTRACTOR IS TO COORDINATE WITH THE SITE IN ADVANCE FOR ANY OUTAGES AS THE SITE WILL BE IN OPERATION DURING WORK.

AutoCAD SHX Text 1 6/16/21 BN UPDATE SECONDARY REQUIREMENTS6/16/21 BN UPDATE SECONDARY REQUIREMENTSBN UPDATE SECONDARY REQUIREMENTSUPDATE SECONDARY REQUIREMENTS

AutoCAD SHX Text REV 1 UPDATED SECONDARY REQUIREMENTS UPDATED ATS4-1 BASIS ADDED GENERAL NOTE f

KEYED NEW WORK NOTES

PREPA

AutoCAD SHX Text

LIVE CAP

AutoCAD SHX Text S1

AutoCAD SHX Text S2

AutoCAD SHX Text X2-1

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text X2-3

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text S3

AutoCAD SHX Text X3-1

AutoCAD SHX Text

MAIN BLDG

AutoCAD SHX Text X2-2

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text X3-2

AutoCAD SHX Text

GREEN HOUSE

AutoCAD SHX Text S4

AutoCAD SHX Text X4-1

AutoCAD SHX Text

LA CUADRA

AutoCAD SHX Text X4-2

AutoCAD SHX Text

AutoCAD SHX Text

DIR HOUSE

AutoCAD SHX Text A,B,N

AutoCAD SHX Text A,B,N

AutoCAD SHX Text

LIVE CAP

AutoCAD SHX Text

3" PVC 3X 10KV 35MM #8G

AutoCAD SHX Text

3" PVC 3X 10KV 35MM #8G

AutoCAD SHX Text

3X 10KV 25MM #10G

AutoCAD SHX Text

3X 10KV 25MM #10G

AutoCAD SHX Text

(3)-10KV 25MM #10G

AutoCAD SHX Text

2" PVC 3X 4/0 THHN #4 GND TYP

AutoCAD SHX Text

2" PVC 3X 4/0 THHN #4 GND TYP

AutoCAD SHX Text

2" PVC 3X 4/0 THHN #4 GND TYP

AutoCAD SHX Text X2-4

AutoCAD SHX Text

SEED COLD STRG

AutoCAD SHX Text

2" PVC 3X 4/0 THHN #4 GND TYP

AutoCAD SHX Text A,B,N

AutoCAD SHX Text 1 BUILDING SERVICE INCLUDES INTEGRATION TO EXISTING BUILDING SERVICE INCLUDES INTEGRATION TO EXISTING AUTOMATIC TRANSFER SWITCH AND EXISTING GENERATOR. 2 BUILDING SERVICE INCLUDES INTEGRATION TO NEW BUILDING SERVICE INCLUDES INTEGRATION TO NEW AUTOMATIC TRANSFER SWITCH AND EXISTING GENERATOR. GENERATOR TO BE RELOCATED FROM TRAILER TO LOCATION DEPICTED ON E100. 3 BUILDING SERVICE INCLUDE INTEGRATION TO NEW BUILDING SERVICE INCLUDE INTEGRATION TO NEW AUTOMATIC TRANSFER SWITCH AND NEW GENERATOR.

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

AutoCAD SHX Text

SCALE:

AutoCAD SHX Text

ELECTRICAL ONE LINE

AutoCAD SHX Text

NTS

AutoCAD SHX Text

AutoCAD SHX Text E200

AutoCAD SHX Text

PPM

AutoCAD SHX Text

REVISIONS

AutoCAD SHX Text

DESCRIPTION

AutoCAD SHX Text

SHEET

AutoCAD SHX Text

DATE

AutoCAD SHX Text c

AutoCAD SHX Text P.A.

AutoCAD SHX Text

FIRM

AutoCAD SHX Text U

AutoCAD SHX Text

NO.

AutoCAD SHX Text D

AutoCAD SHX Text

EPM

AutoCAD SHX Text

SAFETY & HEALTH

AutoCAD SHX Text

REAL PROPERTY

AutoCAD SHX Text A

AutoCAD SHX Text

DATE

AutoCAD SHX Text

PROJECT NO.

AutoCAD SHX Text S

AutoCAD SHX Text

USDA

AutoCAD SHX Text

BY

AutoCAD SHX Text

AGRICULTURAL RESEARCH SERVICE

AutoCAD SHX Text

OF

AutoCAD SHX Text

THE

AutoCAD SHX Text

DESIGNER

AutoCAD SHX Text

PROJECT MANAGER

AutoCAD SHX Text

JOB #

AutoCAD SHX Text

CHECKED BY

AutoCAD SHX Text

A-E FIRM

AutoCAD SHX Text

P.O. BOX 513, GREENWOOD, MISSISSIPPI - (662) 455-4943

AutoCAD SHX Text Johnson M Adams

AutoCAD SHX Text

ARCHITECTS/ENGINEERS PLANNING SURVEYING MANAGEMENT

AutoCAD SHX Text Agricultural

AutoCAD SHX Text Service

AutoCAD SHX Text Research

AutoCAD SHX Text

USDA AGRICULTURAL RESEARCH SERVICE

AutoCAD SHX Text

TROPICAL AGRICULTURAL RESEARCH STATION

AutoCAD SHX Text

MAYAGUEZ, PUERTO RICO

AutoCAD SHX Text

UNDERGROUND ELECTRICAL DISTRIBUTION

AutoCAD SHX Text

ELECTRICAL ONE LINE

AutoCAD SHX Text E200

AutoCAD SHX Text 37 39

AutoCAD SHX Text 7/24/20

AutoCAD SHX Text

BSN

AutoCAD SHX Text

BSN

AutoCAD SHX Text

DRL

AutoCAD SHX Text

MID SOUTH AREA

AutoCAD SHX Text

STONEVILLE, MS

AutoCAD SHX Text 2719-E

AutoCAD SHX Text A,B,N

AutoCAD SHX Text A,B,N

AutoCAD SHX Text A,B,N

AutoCAD SHX Text A,B,N

AutoCAD SHX Text A,B,N

AutoCAD SHX Text A,B,N

AutoCAD SHX Text A,B,N

AutoCAD SHX Text A,B,N

AutoCAD SHX Text A,B,N

AutoCAD SHX Text A,B,N

AutoCAD SHX Text A,B,N

AutoCAD SHX Text

BYPASS

AutoCAD SHX Text

BYPASS

AutoCAD SHX Text

BYPASS

AutoCAD SHX Text

10' CROSSARM

AutoCAD SHX Text 24"

AutoCAD SHX Text

PREPA ENERGY LINE SIDE CONDUCTOR

AutoCAD SHX Text

SOURCE SIDE DISCONNECT

AutoCAD SHX Text

LOAD CONNECTION AND POINT OF DELIVERY

AutoCAD SHX Text

CUSTOMER LOAD-SIDE CONDUCTOR

AutoCAD SHX Text 60"

AutoCAD SHX Text

LOAD SIDE DISCONNECT

AutoCAD SHX Text

NEUTRAL CONNECTION AND POINT OF DELIVERY

AutoCAD SHX Text

CUSTOMER LOAD-SIDE NEUTRAL CONDUCTOR

AutoCAD SHX Text

6'-0" MAX

AutoCAD SHX Text

4'-0" MIN

AutoCAD SHX Text 2'-6"

AutoCAD SHX Text

PREPA LINE NEUTRAL CONDUCTOR

AutoCAD SHX Text

LOAD SIDE

AutoCAD SHX Text

CT

AutoCAD SHX Text L

AutoCAD SHX Text S

AutoCAD SHX Text

PRIMARY

AutoCAD SHX Text

PRIMARY

AutoCAD SHX Text

NEUTRAL

AutoCAD SHX Text

PRIMARY METER

AutoCAD SHX Text

PT

AutoCAD SHX Text

IINSTRUMENT TRANSFORMER AND RACK

AutoCAD SHX Text

METER SOCKET

AutoCAD SHX Text 6"

AutoCAD SHX Text

12' CROSSARM

AutoCAD SHX Text

#4 COPPER BUS TO ARRESTERS

AutoCAD SHX Text

1. CUSTOMER FACILITIES NOT ALLOWED ON PREPA PRIMARY METER POLE. CUSTOMER FACILITIES NOT ALLOWED ON PREPA PRIMARY METER POLE. 2. CUSTOMER SHALL PROVIDE A POLE NEAR PRIMARY METER POLE FOR CUSTOMER SWITCHES, FUSES, AND UNDERGROUND DISTRIBUTION. CUSTOMER SHALL PROVIDE A POLE NEAR PRIMARY METER POLE FOR CUSTOMER SWITCHES, FUSES, AND UNDERGROUND DISTRIBUTION. 3. OVERHEAD TO UNDERGROUND SERVICE CUSTOMERS ARE TO BE SERVED FROM A SEPARATE CUSTOMER OWNED TERMINAL POLE. UNDERGROUND DOES NOT OVERHEAD TO UNDERGROUND SERVICE CUSTOMERS ARE TO BE SERVED FROM A SEPARATE CUSTOMER OWNED TERMINAL POLE. UNDERGROUND DOES NOT ATTACH TO THIS POLE.

AutoCAD SHX Text

NOTES:

AutoCAD SHX Text

SCALE:

AutoCAD SHX Text

UTILITY METERING DETAIL

AutoCAD SHX Text

NTS

AutoCAD SHX Text

AutoCAD SHX Text E200

AutoCAD SHX Text

REV 1 ADDED UTILITY METERING DETAIL

1 6/16/21 BN ADDED UTILITY METERING DETAIL6/16/21 BN ADDED UTILITY METERING DETAILBN ADDED UTILITY METERING DETAILADDED UTILITY METERING DETAIL

File details come from the government source that posted it. Updated .