123174-23001.9 TC Daniel Tompkins Leg Bldg Drawings Combined-FINAL FOR BID.pdf
PDF 3 MB Posted
- Attached to
- Daniel D. Tompkins Roof Project
- Solicitation number
- 2140298
- Issued by
- Tioga County, New York
About this file
This file is a set of architectural and structural drawings for the Daniel D. Tompkins Building Roof Project, a roofing and exterior envelope work project managed by Tompkins County, New York. The drawings document existing conditions, proposed structural modifications, and utility layouts for the building renovation. The project is being procured as a Single Prime General Work contract, with all identified work to be the responsibility of a single general contractor. The drawings include floor plans, elevation details, structural symbols indicating beam designations, joist locations, shear walls, and connection details at a scale of 1/8"=1'-0". Utility infrastructure is documented throughout, including water lines, gas lines, sanitary lines, storm lines, and drainage systems, with notations indicating which utilities are to remain, be removed, or be abandoned. The drawings also contain standard legend symbols for site features such as fencing, fire hydrants, utility poles, tree preservation, and various paving types.
The contract opportunity has no established set-asides for Service-Disabled Veteran-Owned Businesses, Minority Business Enterprises, Women Business Enterprises, or Disadvantaged Business Enterprises, with all goals listed at zero percent. No incumbent contractor is identified, and no identical or substantially similar contract has been awarded within the past five years. The drawings serve as part of the contract documents that define the scope of work for bidders responding to this Tompkins County procurement. Additional contract details including pricing terms, response deadlines, and funding sources would be found in the associated specifications and bid documents referenced alongside these drawings.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
E
FENCING TO REMAIN
W
G
SAN
ST
UD
W
G
SAN
UD
ST
MATCH LINE
ELEVATION
INTERIOR
ELEVATION
ELEVATION FROM DATUM
SCHEDULE
INDICATES FRAMED
LOCATION
LENGTH OF BEAMRECESSED
0.7
[-3'-0]
P1
CFMF BEARING WALL
AT ADJ GIRDER ELEV
INDICATES TOP OF BEAM(GIR)
SHEAR WALL
SEE SCHEDULE
HORIZONTAL BRIDGING
JOIST
JOIST DESIGNATION
12K3
F4
(-8)
REFER TO FOOTING
INDICATES FOOTING TYPE
INDICATES PIER TYPE
TOP OF PIER ELEVATION
TOP OF FOOTING
SL = SKYLIGHT
AH = ACCESS HATCH
SH = SMOKE HATCH
BEARING WALL
MASONRY LOAD
INDICATES AREA IS
EXISTING
DEPRESSED OR
INDICATES SLAB IS
APPROX W/ WET CONC
DEFLECTION (INCHES)
END REACTION- KIPS
BEAM SIZE
STUDS OVER FULL
NUMBER OF SHEAR
DRAWING DATUM
ELEVATION FROM
(-6) W8X15
RD
OPNG IS FOR:
RD = ROOF DRAIN
ME = MECH EQUIP
INDICATES A FRAMED
ROOF OR FLOOR OPNG
COORD SIZE AND
FIREWALL
CONNECTION
COLUMN
LINTEL DESIGNATION
SEE SCHEDULE
L-2 *
CONNECTION TO
INDICATES LINTEL
INDICATES MOMENT
IS EXISTING
INDICATES MEMBER
INDICATES BM TO HAVE
INDICATES SHEAR WALL
INDICATES BEAM FRAMES
OVER COLUMN
SPLICE
INDICATES BEAM
CONNECTION TO BEAM
TOP OF WALL CLIPS
21K21K
FROM DATUM
[14]
DIAGONAL BRIDGING
1st FF 100'-0"
A A
B B
A112
4 A112
A12
A112
A112
A112
A12
Standard SymbolsStructural SymbolsSite Symbols
CLL
A COLUMN CENTER
LINE
CONTRACT LIMIT LINE
PROPERTY LINE
STANDARD REFERENCE BUBBLE
DRAWING TITLE & SCALE
Floor Plan 1/8"=1'-0"
RIP-RAP
HAY BALES
TEMPORARY TREE PROTECTION
TEMPORARY CONSTRUCTION FENCING
GATE VALVE
CO
STORM/SANITARY CLEANOUT
WATER LINE TO BE REMOVED/ABANDONED
WATER LINE TO REMAIN
WATER LINEW
GAS LINE TO BE REMOVED/ABANDONED
GAS LINE TO REMAIN
GAS LINEG
SANITARY LINE TO BE REMOVED/ABANDONED
SAN
REMOVAL
SANITARY LINE TO REMAIN
SANITARY LINE
UNDERDRAIN TO BE REMOVED/ABANDONED
ST STORM LINE WITH END SECTION
STORM LINE WITH ENDWALLST
ST
STORM PIPE TO REMAIN
DRYWELL W/ COVER BURIED
DRYWELL W/ SOLID COVER TO GRADE
DRYWELL W/ GRATE
STORM/SANITARY MANHOLE
CONCRETE SECTION
BC
TC
+ 99.00 BOTTOM OF CURB ELEVATION
83.36 SPOT ELEVATION
UNIVERSAL HANDICAP SYMBOL
SIGN POST
STORM LINE WITH HEADWALL
TO REMAIN
SILT FENCING
ST STORM PIPE
MANHOLE/CATCH BASIN/DRYWELL
CATCH BASIN
DROP INLET TO REMAIN
DROP INLET
FIRE HYDRANT TO REMAIN
NEW OR RELOCATED FIRE HYDRANT
UTILITY POLE TO REMAIN
UTILITY POLE
FENCING TO BE REMOVED
TB-1
+ 83.36
99.50
FENCING
SOIL TEST BORING
EXISTING CONTOUR
CONTOUR
EXISTING SPOT ELEVATION
TOP OF CURB ELEVATION
TREE OR SHRUB TO BE REMOVED
TREE OR SHRUB TO REMAIN
TREE OR SHRUB
CURBING TO BE REMOVED
CURBING
CURBING TO REMAIN
CONCRETE PAVING
REMOVE AND REPLACE ASPHALT PAVING
HEAVY-DUTY ASPHALT PAVING
ASPHALT PAVING OR TOP COURSE
UD
UNDERDRAIN TO REMAIN
UNDERDRAIN
STORM PIPE TO BE REMOVED/ABANDONED
TP-1
TEST PIT LOCATION
UTILITY POLE TO BE REMOVED
DRAWING REVISION
NUMBER
CENTER LINE
CUT LINE
NORTH ARROW ROOM NAME AND
NUMBER
DETAIL
WALL SECTION
BUILDING SECTION
DRAWING NUMBER
DETAIL NUMBER
METAL, STEEL
REMOVE AND REPLACE
ASPHALT PAVING
NEW HEAVY-DUTY
ASPHALT PAVING
NEW ASPHALT PAVING OR
TOP COURSE
SAND
GRAVEL
CONCRETE
BRICK
EARTH
STONE
CONCRETE MASONRY UNITS
PLYWOODFINISHED WOOD TRIM
ROUGH WOODINSULATION (LOOSE OR
BATT)
RIGID INSULATION
CERAMIC TILEACOUSTICAL PANEL
GLASS (LARGE SCALE)
PLASTER, CEMENT, GROUT, GYPSUM
WALL BOARD
RESILIENT FLOORING
TERRAZZO
STRUCTURAL GLAZED TILE
ADA 5' TURNING
RADIUS
ELEVATION CALL
OUT
CLASSROOM
N
FOUNDATION WALL
CONTINUOUS FTG
BM POCKET
ELEVATION FROM DATUM
SW1 WALL TYPE
<-1'-8>
[-4'-0] [-3'-0]
FROM DATUM
TOP OF FTG ELEVATION
STEPPED FOOTING
N
Tetra Tech Engineers, Architects & Landscape Architects, P.C.
Set No.
Project Location Map
Drawing Number:
Architecture fo r High PerformanceFacilities
PlanningEngineering To the best of the Architect’s knowledge, information and belief, the design of this project conforms to all applicable provisions of the New York State Uniform Fire Prevention and Building Code, the New York State Energy Conservation Code, and the building standards of the New York State Education Department. It is a violation of the Education Law of the State of New York for any person to alter or modify this document in any way unless acting under the direction of a licensed architect.
Date:Drawn By: Drawing Number:
Project No.:
BUILDING DESIGNATOR
DISCIPLINE DESIGNATOR
SHEET TYPE DESIGNATOR
SHEET SEQUENCE DESIGNATOR
AA130
Volume 1 of 1
123174-23001.9 August 26, 2026 G001
121 E Court Street Ithaca, New York 14850
Daniel D. Tompkins Roof Project Tompkins County
The engineer that has signed this document certifies that to the best of their knowledge, information and belief, the asbestos plans and specifications are in accordance with applicable requirements of the New York State Uniform Fire Prevention and Building Code, Construction Standards of the Commissioner of Education, New York State Department of Labor Part 56 of Title 12, and the United States Environmental Protection Agency Hazard Emergency Response ACT Regulations. Kevin C. Terry is accredited to the EPA and New York State under AHERA Regulations as an Asbestos Project Designer (Asbestos Handling Certificate Number 14-20336). It is a violation of the Education Law of the State of New York for any person to alter or modify this document in any way unless acting under the direction of a licensed professional engineer.
123174-23001.9
August 26, 2026TTAE
Drawing List
GENERAL
G001 Title Sheet and Symbols and Abbreviations
Daniel D. Tompkins Building
HAZARDOUS MATERIALS
AH100 Abatement Plan
ARCHITECTURAL
AA190 Roof Plan and Photos AA191 Details AA200 Exterior Elevations and Photos
PROJECT LOCATION MAP
DANIEL D TOMPKINS BUILDING
121 E COURT STREET1
A
A/S AIR SEPARATOR
AAC ASBESTOS ABATEMENT
CONTRACTOR
AAD AUTOMATIC AIR DAMPER
AB ANCHOR BOLT, AIR BARRIER
AC AIR CONDITIONING,
ALTERNATING CURRENT
ACCMP ASPHALT COATED CORR
METAL PIPE
ACM ASBESTOS CONTAINING
MATERIAL
ACT ACOUSTICAL CEILING TILE
ACU AIR CONDITIONING UNIT
AD AREA DRAIN
ADA AMERICAN DISABILITIES ACT
ADD ADDENDUM
ADDL ADDITIONAL
ADDN ADDITION
ADH ADHESIVE
ADJ ADJACENT
ADR ACCESS DOOR
AESS ARCH EXPOSED STRUCTURAL
STEEL
AFF ABOVE FINISH FLOOR
AH ACCESS HATCH
AHU AIR HANDLING UNIT
AIB AIR INFILTRATION BARRIER
ALT ALTERNATE
ALTB ACOUSTICALLY LINED
TRANSFER BOX
ALTN ALTERATION
ALUM ALUMINUM
AMP AMPERE
ANOD ANODIZED
ANT ACID NEUTRALIZATION TANK
AP ACCESS PANEL, APPROX,
APPROXIMATE(LY)
APC ARCHITECTURAL PRECAST
CONCRETE
ARCH ARCHITECT (URAL)
ASB ASBESTOS
ASPH ASPHALT
ATV ATMOSPHERIC VENT
AUD AUDITORIUM
AUTO AUTOMATIC
AVE AVERAGE
B
B BOILER, BRICK, BOTTOM
BB BASKETBALL
BBD BOILER BLOWDOWN
BC BOTTOM OF CURB
BCU BLOWER COIL UNIT
BCX BOTTOM CHORD EXTENSION
BD BOARD
BDD BACKDRAFT DAMPER
BF BACK FLOW PREVENTER
BG BOTTOM GRILLE
BIT BITUMINOUS
BLDG BUILDING
BLK BLOCK
BLKG BLOCKING
BM BEAM
BO BY OTHERS
BOD BOTTOM OF DUCT
BOF BOTTOM OF FOOTING
BOS BOTTOM OF STEEL
BOT BOTTOM
BPL BEARING PLATE
BR BOTTOM REGISTER
BRDG BRIDGING
BRG BEARING
BRK BRICK
BRSH BRICKSHELF
BRZ BRONZE
BS BOTH SIDES, BOTTOM OF
STAIR
BSMT BASEMENT
BSPL BACKSPLASH
BT BENT
BTU BRITISH THERMAL UNITS
BTUH BRITISH THERMAL UNITS PER
HOUR
BUR BUILT-UP ROOFING
BW BOTTOM OF WALL
BWC BACK WATER CHECK VALVE
C
C CONDUIT, CONVECTOR,
CONDENSOR, COMMON,
CARPET
CA COMPRESSED AIR
CAB CABINET
CATV CABLE TELEVISION
CB CATCH BASIN, CIRCUIT
BREAKER, CHALKBOARD
CCTV CLOSED CIRCUIT TELEVISION
CD CEILING DIFFUSER,
CONDENSATE DRAIN
CEM CEMENT
CER CERAMIC
CF CUBIC FEET, CEILING FAN
CFM CUBIC FEET PER MINUTE
CFMF COLD FORMED METAL
FRAMING
CFT CERAMIC FLOOR TILE
CG CEILING GRILLE
CHAN CHANNEL
CHUV CEILING HUNG UNIT
VENTILATOR
CI CAST IRON
CIP CAST IN PLACE
CIRC CIRCUMFERENCE
CJ CONTROL JOINT
CL CENTER LINE
CLG CEILING
CLKG CAULKING
CLL CONTRACT LIMIT LINE
CLR CLEAR (ING) (ENCE)
CLRM CLASSROOM
CMP CORRUGATED METAL PANEL
CMT CERAMIC MOSAIC TILE
CMU CONCRETE MASONRY UNIT
CO CLEAN OUT
CODP CLEAN OUT DECK PLATE
COL COLUMN
COMB COMBINATION
COMP COMPRESS (ED) (ION) (IBLE),
COMPOSITE
CONC CONCRETE
COND CONDENSATE
CONN CONNECTION
CONST CONSTRUCTION
CONT CONTINUOUS
CONTR CONTRACT (OR)
COORD COORDINATE
CORR CORRUGATED, CORRIDOR
COWP CLEAN OUT WALL PLATE
CPVC CHLORINATED POLY VINYL
CHLORIDE
CR CEILING REGISTER
CRS COURSE (S)
CSK COUNTERSINK
CSMT CASEMENT
CT COMPUTER TERMINAL,
CERAMIC BASE TILE
CTD COATED
CTOP COUNTER TOP
CTR CENTER
CU CUBIC
CUH CABINET UNIT HEATER
CV CONVECTOR, CURB VALVE
CW COLD WATER
CWR CHILLED WATER RETURN
CWS CHILLED WATER SUPPLY
CWT CERAMIC WALL TILE
D
D DIESEL FUEL, DEPTH
DB DRY BULB
DC DIRECT CURRENT
DDC DIRECT DIGITAL CONTROL
DE DELONIZED WATER
DEG DEGREES
DEMO DEMOLISH
DEP DEPRESS (ED) (ION)
DET DETAIL (ED)
DF DRINKING FOUNTAIN
DH DOUBLE HUNG
DHU DEHUMIDIFICATION UNIT
DI DROP INLET, DUCTILE IRON,
DISTILLED WATER
DIA DIAMETER
DIAG DIAGONAL
DIM DIMENSION
DISP DISPENSER
DIST DISTANCE
DIV DIVISION
DL DEAD LOAD
DN DOWN
DO DITTO
DP DAMPPROOF (ING)
DPR DAMPER
DR DOOR, DEEP RIB
DS DOWNSPOUT, DRAINAGE
STRUCTURE
DT DRAIN TILE
DTA DOVETAIL ANCHOR
DTL DETAIL
DTR DUAL TEMPERATURE RETURN
DTS DUAL TEMPERATURE SUPPLY
DW DUMBWAITER, DISHWASHER
DWG DRAWING
DWL DOWEL
DWR DRAWER
E
E EAST
EA EXHAUST AIR, EACH
EAT ENTERING AIR TEMPERATURE
EB EXPANSION BOLT
EC ELECTRICAL CONTRACTOR
ECF ENHANCED CONCRETE
FLOORING
EF EACH FACE, EXHAUST FAN
EIFS EXTERIOR INSULATION
SYSTEM
EJ EXPANSION JOINT
ELEC ELECTRIC (AL)
ELEM ELEMENT
ELEV ELEVATION, ELEVATOR
EM EMERGENCY
EMT ELECTRICAL METALLIC
TUBING
ENC ENCLOSURE
EOD EDGE OF DECK
EOS EDGE OF SLAB
EQ EQUAL, EQUIVALENT
EQC EQUIPMENT CONTRACTOR
EQUIP EQUIPMENT
ERU ENERGY RECOVERY UNIT
ERV ENERGY RECOVERY
VENTILATION
ES EXPOSED SURFACE,
EXPOSED STRUCTURE
ESF ELASTIC SHEET FLASHING
ESM ELASTIC SHEET MEMBRANE
EW EACH WAY
EWC ELECTRIC WATER COOLER
EWT ENTERING WATER
TEMPERATURE
EXG EXISTING
EXH EXHAUST
EXP EXPANSION
EXT EXTERIOR, EXTERNAL
F
F FAHRENHEIT
FA FIRE ALARM
FAI FRESH AIR INTAKE
FCU FAN COOLING UNIT
FD FLOOR DRAIN, FIRE DAMPER
FDC FDCFIRE DEPARTMENT
CONNECTION
FE FIRE EXTINGUISHER
FEC FIRE EXTINGUISHER CABINET
FF FINISH FLOOR, FACTORY
FINISH
FFE FINISH FLOOR ELEVATION
FFL FINISH FLOOR LINE
FG FLOOR GRILLE
FH FIRE HYDRANT
FHC FIRE HOSE CABINET
FIN FINISH (ED)
FIXT FIXTURE
FL FLUSH
FLD FLOOR DUCT
FLEX FLEXIBLE
FLG FLASHING
FLR FLOOR (ING)
FLUOR FLUORESCENT
FM FLOOR MOUNTED
FMC FLEXIBLE METAL CONDUIT
FND FOUNDATION
FOB FREIGHT ON BOARD, FLAT ON
BOTTOM
FOG FUEL OIL GAUGE
FOR FUEL OIL RETURN
FOS FUEL OIL SUPPLY
FOT FLAT ON TOP
FP FIREPROOF (ING)
FPM FEET PER MINUTE
FR FRAME, FLOOR REGISTER
FRA FRESH AIR
FRC FIRE RESISTANT COATING
FRP FIBERGLASS REINFORCED
PANEL
FRT FIRE RETARDANT
FS FLOOR SINK
FSD FIRE AND SMOKE DAMPER
FT FEET, FLOOR TREATMENT
FTG FOOTING
FTR FIN TUBE RADIATION
FV FLUSH VALVE
G
G GAS, GLYCOL
GA GAUGE
GAL GALLON
GALV GALVANIZED
GASK GASKET (ED)
GC GENERAL CONTRACT (OR)
GCMU GLAZED CONCRETE
MASONRY UNIT
GCO GRADE CLEANOUT GF
GROUND FACE
GL GLASS, GLAZING
GND GROUND
GPM GALLONS PER MINUTE
GR GRADE (ING), GLYCOL
RETURN
GS GLYCOL SUPPLY
GVL GRAVEL
GWB GYPSUM WALL BOARD
GYP GYPSUM
H
H HEIGHT
HB HOSE BIB
HBD HARD BOARD
HC HEATING CONTRACT (OR),
HANDICAP
HCR HOT/CHILLED RETURN
HCS HOT/CHILLED SUPPLY
HD HEAVY DUTY
HDPE HIGH DENSITY
POLYETHYLENE
HDR HEADER
HDW HARDWARE
HG HOT GLYCOL
HIP HIGH IMPACT PANEL
HM HOLLOW METAL
HORZ HORIZONTAL
HP HORSEPOWER, HIGH
PRESSURE, HEAT PUMP
HPC HIGH PERFORMANCE
COATING
HPL HIGH PRESSURE LAMINATE
HPR HEAT PUMP LOOP WATER
RETURN
HPS HEAT PUMP LOOP WATER
SUPPLY
HR HANDRAIL, HOUR
HT HEIGHT
HTG HEATING
HV HIGH VOLTAGE
HVAC HEATING/VENTILATING/AIR
CONDITIONING
HVU HEATING AND VENTILATING
UNIT
HW HOT WATER
HWH HOT WATER HEATER
HWP HOT WATER PUMP
HWR HOT WATER RETURN
HWS HOT WATER SUPPLY
I
ID INSIDE DIAMETER
IE INVERT ELEVATION
IN INCHES
INCL INCLUDE (D) (ING)
INS INSULATE (D) (ION)
INT INTERIOR
INV INVERT
IP IRON PIPE
IPS IRON PIPE SIZE
IW INDIRECT WASTE
J
J JANITORS CLOSET
JAN JANITORS CLOSET
JB JUNCTION BOX
JC JANITORS CLOSET
JCT JUNCTION
JT JOINT
K
KV KILOVOLT
KVA KILOVOLT AMPERE
KW KILOWATT
KWH KILOWATT PER HOUR
L
L LENGTH, LONG
LAB LABORATORY
LAD LADDER
LAM LAMINATE (D)
LAT LEAVING AIR TEMPERATURE
LAV LAVATORY
LB POUND
LBL LABEL
LBP LEAD BASED PAINT
LC LANDSCAPE CONTRACTOR
(SITE)
LCC LEAD COATED COPPER
LDR LEADER
LEV LEVEL
LF LINEAR FOOT
LFMC LIQUID-TIGHT FLEXIBLE
METAL CONDUIT
LFNC LIQUID-TIGHT FLEXIBLE
NONMETALLIC CONDUIT
LG LENGTH, LONG
LGI LARGE GROUP INSTRUCTION
LH LEFT HAND
LIN LINEAR
LKR LOCKER
LL LIVE LOAD
LP LOW PRESSURE
LPC LOW PRESSURE
CONDENSATE
LPG LIQUID PROPANE GAS
LPS LOW PRESSURE STEAM
LPT LOW POINT
LS LINOLEUM SHEET
LT LIGHT, LINOLEUM TILE
LTL LINTEL
LV LABORATORY VENT, LOW
VOLTAGE
LVR LOUVER
LW LABORATORY WASTE
LWT LEAVING WATER
TEMPERATURE
M
MAN MANUAL
MAS MASONRY
MAT MATERIAL
MAU MAKE UP AIR UNIT
MAX MAXIMUM
MB MARKER BOARD
MBH THOUSAND BTUH
MBR MEMBER
MD MOTORIZED DAMPER
ME MECHANICAL EQUIPMENT
MECH MECHANICAL (LY)
MED MEDIUM
MEMB MEMBRANE
MF MIXING FAUCET
MFR MANUFACTURE (R)
MH MAN HOLE
MIN MINIMUM
MIR MIRROR
MISC MISCELLANEOUS
MO MASONRY OPENING
MOD MODULE (OR), MODEL
MP MULTICOLOR WALL COATING
MR MOP RECEPTOR
MT MOUNT
MTD MOUNTED
MTG MOUNTING
MTH MARBLE THRESHOLD
MTL METAL
MTR METER
MULL MULLION
MVEJ MASONRY VENEER
EXPANSION JOINT
N
N NORTH
NAT NATURAL
NC NORMALLY CLOSED
NEC NATIONAL ELECTRIC CODE
NEG NEGATIVE
NEUT NEUTRALIZATION
NG NATURAL GAS
NIC NOT IN CONTRACT
NO NUMBER, NORMALLY OPEN
NOM NOMINAL
NRC NOISE REDUCTION
COEFFICIENT
NTS NOT TO SCALE
O
OA OVERALL, OUTSIDE AIR
OC ON CENTER
OD OUTSIDE DIAMETER
OH OVERHEAD
OPNG OPENING
OPP OPPOSITE
OPP HD OPPOSITE HAND
P
P PAINT SURFACE(S) INCLUDING
SOFFITS
PAR PARALLEL
PART PARTITION
PC PLUMBING CONTRACT (OR),
PIGMENTED CONCRETE
PCC PRECAST CONCRETE
PE PORCELAIN ENAMEL
PENC PRE-EXISTING
NON-CONFORMING
PERF PERFORATE (ION) (ED)
PERI PERIMETER
PERP PERPENDICULAR
PL PLATE, PROPERTY LINE
PLAM PLASTIC LAMINATE
PLAS PLASTER, PLASTIC
PLF POUNDS PER LINEAR FOOT
PLYWD PLYWOOD
PM PLUGMOLD
PNL PANEL
POC POINT OF CURVATURE, POINT
OF CONNECTION
POL POLISHED
POS POSITIVE
POT POINT OF TANGENCY
PR PAIR
PRE POWER ROOF EXHAUSTER
PREP PREPARE (ATION)
PRF PREFORMED
PROJ PROJECT
PS PAINT EXPOSED
STRUCTURE/DECK
PSF POUNDS PER SQUARE FOOT
PSI POUNDS PER SQUARE INCH
PT POINT, PORCELAIN TILE
PTD PAINTED
PTFR PRESSURE TREATED FIRE
RETARDANT
PTP PRESSURE TREATED
PRESERVATIVE
PVC POLYVINYL CHLORIDE
PVMT PAVEMENT
PWE POWER WALL EXHAUSTER
Q
QF QUARTZ FLOORING
QT QUARRY TILE
R
R RADIUS, RETURN,
REFRIGERANT
RA RETURN AIR
RAD RADIATION
RAF RETURN AIR FAN, RESILIENT
ATHLETIC FLOORING
RB RESILIENT BASE
RC ROOFING CONTRACT (OR)
RCA RECYCLED CONCRETE
AGGREGATE
RCP REINFORCED CONCRETE
PIPE, REFLECTED CEILING
PLAN
RCU REMOTE CONDENSING UNIT
RD ROOF DRAIN
RECEP
T
RECEPTACLE
REF REFERENCE
REFL REFLECT (ED) (IVE) (OR)
REFR REFRIGERATOR
REG REGISTER
REINF REINFORCE (D) (ING)
REM REMOVED
REQD REQUIRED
RESIL RESILIENT
RET RETAINING, RETURN
REV REVISION, REVISED, REVEAL
RF RUBBER FLOORING
RFG ROOFING
RFH ROOF HATCH
RFM RECESSED FLOOR MAT
RG RETURN GRILLE
RGS RIGID GALVANIZED STEEL
RH RIGHT HAND
RHC REHEAT COIL
RI ROUGH-IN
RL RAIN LEADER, REFRIGERANT
LIQUID
RLG RAIL(ING)
RM ROOM
RMC RIGID METAL CONDUIT
RNC RIGID NONMETALLIC CONDUIT
RNT RUNNING TRAP
RO ROUGH OPENING
ROW RIGHT OF WAY
RPM REVOLUTIONS PER MINUTE
RR REMOVE EXISTING AND
REPLACE WITH NEW
RS RUBBER STAIR TREAD/RISER,
REFRIGERANT SUCTION
RTH ROOF TOP HOOD
RTU ROOF TOP UNIT
RW RAW WATER
S
S SOUTH, SUPPLY, SURGE
PROTECTED
SA SUPPLY AIR
SAN SANITARY
SAS SMOOTH ALL SIDES
SC SOLID CORE, SILL COCK,
SEALED CONCRETE
SCHED SCHEDULE
SCT STRUCTURAL CLAY TILE
SD STORM DRAIN, SPLITTER
DAMPER, SMOKE DAMPER
SEC SECTION
SF SQUARE FEET
SGI SMALL GROUP INSTRUCTION
SGT STRUCTURAL GLAZED TILE
SH SHELF, SHELVING, SMOKE
HATCH
SHR SHOWER, SHEAR WALL
SHT SHEET
SHTHG SHEATHING
SIM SIMILAR
SK SINK
SL SOUND LINED, SKYLIGHT
SLC SILLCOCK
SLV SLEEVE
SLVR STORM LOUVER
SMH SANITARY MANHOLE
SOG SLAB ON GRADE
SP STATIC PRESSURE,
STANDPIPE, SPACE (ING) (ES)
SPEC SPECIFICATION (S)
SPKR SPRINKLER
SPL SPECIAL
SQ SQUARE
SS STAINLESS STEEL
SST STRUCTURAL STEEL TUBING
ST STORM, STORAGE
STA STATION
STC SHOWER TEMPERATURE
CONTROLLER, STAINED
CONCRETE
STD STANDARD
STG SEATING
STL STEEL
STN STAIN (ED)
STOR STORAGE
STRU STRUCTURAL
SURF SURFACE
SUSP SUSPSUSPENDED
SV SHEET VINYL, STEAM VENT
SW SWITCH, SOFTENED WATER
SWCI SERVICE WEIGHT CAST IRON
SYM SYMMETRICAL
SYN SYNTHETIC
SYS SYSTEM
T
T TREAD, TOP, TOILET ROOM,
TONS, TERRAZZO
TB TOP AND BOTTOM, TACK
BOARD, TERRAZZO BASE
TBD TO BE DETERMINED
TC TEMPERATURE CONTROL,
TEMPERED CLEAR,
TELECOMMUNICATION
CONTRACTOR, TOP OF CURB
TCX TOP CHORD EXTENTION
TDV TRIPLE DUTY VALVE
TEL TELEPHONE
TEMP TEMPERATURE
TG TOP GRILLE, TONGUE AND
GROOVE
THK THICKNESS
THR THRESHOLD
TME TO MATCH EXISTING
TMV THERMOSTATIC MIXING
VALVE
TOD TOP OF DUCT
TOF TOP OF FASCIA, TOP OF
FOOTING
TOL TOLERANCE
TOM TOP OF MASONRY
TOP TOP OF PIPE, TOP OF PIER
TOS TOP OF STEEL, TOP OF STAIR
TPART TOILET PARTITION
TR TOP REGISTER
TRN TRANSOM
TS TOP OF STAIR
TV TELEVISION
TW TEMPERED WATER, TOP OF
WALL
TYP TYPICAL
U
UC UNDERCUT
UD UNDERDRAIN
UE UNDERGROUND ELECTRIC
UG UNDERGROUND
UH UNIT HEATER
UNF UNFINISHED
UNIF UNIFORM
UNO UNLESS NOTED OTHERWISE
UR URINAL
UT UNDERGROUND TELEPHONE
UV UNIT VENTILATOR
V
V VENT, VOLT
VAR VARIES, VARIABLE
VARN VARNISH
VAT VINYL ASBESTOS TILE
VAV VARIABLE AIR VOLUME
VB VACUUM BREAKER, VAPOR
RETARDER BARRIER,
VOLLEYBALL
VCB VENTED COVE BASE
VCT VINYL COMPOSITE TILE
VD VOLUME DAMPER
VERM VERMICULITE
VERT VERTICAL
VEST VESTIBULE
VIF VERIFY IN FIELD
VIN VINYL
VIT VITREOUS TILE
VNR VENEER
VOL VOLUME
VTR VENT THROUGH ROOF
VWC VINYL WALL COVERING
W
W WEST, WIDTH, WIDE, WASTE,
WATT
W/ WITH
W/O WITHOUT
WB WET BULB
WC WATER CLOSET, WALL
COVERING
WD WOOD, WOOD FLOORING
WDW WINDOW
WDWC WINDOW CONTRACTOR
WF WASH FOUNTAIN
WG WALL GRILLE, WATER GAUGE
WH WALL HUNG, WALL HYDRANT
WHA WATER HAMMER ARRESTOR
WI WROUGHT IRON
WM WIREMOLD
WP WATER PROOFING, WORKING
POINT
WR WATER REPELLENT, WIDE RIB,
WALL REGISTER
WS WATER STOP
WSCT WAINSCOT
WT WEIGHT
WWHP WATER TO WATER HEAT
PUMP
WWR WELDED WIRE
REINFORCEMENT
X
XHCI EXTRA HEAVY CAST IRON
Y
YD YARD DRAIN, YARD
B
A
A
B
REMOVE ROOFING PLYWOOD AND ASBESTOS CONTAINING
ICE & WATER MEMBRANE
REMOVE ASBESTOS CONTAINING ROOFING MASTIC FROM
WITHIN ABANDONED YANKEE GUTTER SYSTEM
REMOVE LEAD CONTAINING RAILING/TRIM CAULK
Legend
A
B
1. CONTRACTOR PERFORMING ANY AND ALL ASBESTOS ABATEMENT
WORK SHALL BE A NYSDOL LICENSED ASBESTOS CONTRACTOR.
2. PERFORM ALL WORK IN ACCORDANCE WITH SPECIFICATION
SECTION 02 82 00 - ASBESTOS ABATEMENT.
3. ASBESTOS CONTAINING MATERIALS SHALL BE ABATED IN
ACCORDANCE WITH THE DRAWINGS AND SECTION 02 82 00 PRIOR
TO ANY GENERAL DEMOLITION WORK THAT COULD DISTURB THOSE
MATERIALS.
4. DO NOT SCALE DRAWINGS.
5. COORDINATE ALL WORK WITH OTHER CONTRACTORS.
6. THE CONTRACTOR IS RESPONSIBLE FOR OBTAINING ANY AND ALL
VARIANCES FROM INDUSTRIAL CODE RULE 56, WHICH ARE DESIRED
OR NECESSARY TO PERFORM THE WORK.
7. REMOVE ALL ABATED MATERIALS FROM THE WORK AREA AND /OR
BUILDING IN SEALED BAGS, DRUMS OR PLASTIC SHEETING.
Asbestos Abatement General Notes
1. EACH PRIME CONTRACTOR IS RESPONSIBLE FOR THEIR OWN WORK
WHICH WILL DISTURB LEAD PAINTED OR CONTAINING MATERIALS IN
AN AUXILLARY MANNER. CONTRACTOR RESPONSIBLE FOR
ABATEMENT SHALL BE RESPONSIBLE FOR ALL LEAD WORK
EXPLICITLY INDICATED HEREIN.
2. ALL PAINTED SURFACES ARE PRESUMED TO HAVE LEAD-BASED
PAINT.
3. PERFORM ALL WORK THAT WILL DISTURB LEAD-BASED PAINT IN
ACCORDANCE WITH SECTION 02 83 00 - LEAD-SAFE WORK
PRACTICES.
Lead Safe Work Practices
1. PLYWOOD SUBSTRATE LOCATED BENEATH THE METAL ROOF
SYSTEM IS LAMINATED WITH ASBESTOS CONTAINING ASPHALT ICE &
WATER SHIELD MEMBRANE. MEMBRANE IS PRESENT AT THE LOW
ENDS AND IS ASSUMED TO EXTEND FULL HEIGHT OF THE ENTIRE
SLOPED ROOF.
2. ICE & WATER MEMBRANE IS NON-FRIABLE IN ITS OBSERVED
CURRENT CONDITION AND ADHERED TO THE PLYWOOD SUBSTRATE.
AT ALL LOCATIONS OF ACM ICE & WATER MEMBRANE, REMOVE
MEMBRANE AND PLYWOOD. DISPOSE OF MEMBRANE AND PLYWOOD
AS NON-FRIABLE ASBESTOS CONTAINING MATERIAL.
3. AT THE LOW END OF THE SLOPED ROOF, AN OLD YANKEE GUTTER
SYSTEM IS CONCEALED BENEATH THE EXISTING ROOF AND
PLYWOOD. THE YANKEE GUTTER IS LINED WITH SHEET METAL. AT
THE TOP EDGE OF THE SHEET METAL/GUTTER, ASBESTOS
CONTAINING ROOFING MASTIC IS PRESENT. REMOVE ALL ROOFING
MASTIC FROM THE YANKEE GUTTER.
4. PERFORM WORK IN ACCORDANCE WITH CODE RULE 56-11.6 AND
SPECIFICATION SECTION 028200 - ASBESTOS ABATEMENT.
Roof System Abatement Notes
1. IN INDICATED AREAS, CAULKING ASSOCIATED WITH THE WOOD
RAILINGS/TRIM IS LEAD CONTAINING. NOT ALL RAILINGS/TRIM ARE
SCHEDULED FOR REMOVAL. REMOVE ALL CAULKING ASSOCIATED
WITH ALL RAILINGS/TRIM IN INDICATED AREAS AND DISPOSE OF AS
LEAD CONTAINING.
2. CAREFULLY REMOVE CAULKING FROM SUBSTRATE. SOME
SUBSTRATES ARE SCHEDULED TO REMAIN.
Railing/Trim Caulk Abatement Notes
N
Date:Drawn By: Drawing Number:
Project No.:
A B
C D
E F
G H
I J
K L
M N
2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17
A B
C D
E F
G H
I J
K L
M N
Tetra Tech Engineers, Architects & Landscape Architects, P.C.
CLEAR SOLUTIONS
complex world
Key Plan N.T.S.
It is a v io la tio n of th e Ed uc at io n
La w o f t he S ta te o f N ew Y or k fo r a ny p er so n to a lte r o r m od ify th is d oc um en t i n an y w ay u nl es s ac tin g un de r t he d ire ct io n of a li ce ns ed a rc hi te ct
123174-23001.9 AH100
August 26, 2026
Abatement Plan
TJT
Tompkins County Ithaca, NY
Daniel D. Tompkins Roof Project Alterations to:
1/4" = 1'-0"1 Abatement Plan
Rev. No.: Date: Description:
AA200
AA200
AA200
AA200
SV
RH
30" +/-
36" +/-
36" +/-
30" +/-
LO
HI
ST
R
U
SL
O
PE
/1
VI
F
ST
R
U
SL
O
PE
/1
VI
F
LO
HI
HI
LO
HI LO
LO HI
HI
LO
HI LO
LO HIHI LO
W
4TYP
T
1/4"/FT
T 1/
4" /F
T T
1/ 4"
/F T
T
1/4"/FT
10TYP
TYP
TYP
AT FLOOR
BELOW
ROOF, VIF
RS-3
RS-1
RS-2
RS-2
ST
R
U
SL
O
PE
/1
VI
F
16 19
16TYP
TYP
TYP
AA190
AA190
AA190
AA191
AA191
AA191
AA191
RS-3
AA190
+1"+1"
+3" (VIF)
+1"
+1"
AA191
ST
R
U
SL
O
PE
/1
VI
F
PROVIDE 1" EXPANSION JOINT
BETWEEN MEMBRANE AND METAL
ROOF SNOW GUARD SYSTEMS
INTEGRAL
GUTTER
AA191
AA191
AA191
C O
N T
FA
SC
IA
F
R O
M R
ID
G
E
TO
W
AL
L
AA191TYP
VENT PIPE PENETRATION (VERIFY DIMENSIONS IN FIELD) REMOVE
EXISTING FLASHINGS. SEE DETAIL .
REMOVE EXISTING ROOF HATCH. PROVIDE ROOF HATCH AND
SAFETY RAIL SYSTEM. APPROXIMATE DIMENSION INDICATED ON
PLAN (VERIFY DIMENSIONS IN FIELD). SEE DETAIL .
PROVIDE ADHERED WALKWAY PADS. SEE DETAIL .
PROVIDE MEMBRANE BASE FLASHING, COPPER COUNTER FLASHING
AND SEALANT. SEE DETAIL .
PROVIDE ½”/FT TAPERED INSULATION CRICKET
REMOVE TWO EXISTING WOOD LADDERS AT BOTTOM AND TOP
LEVELS (MIDDLE LEVEL WOOD LADDER IS TO REMAIN). PROVIDE
TWO ALUMINUM LADDERS, BOTTOM LEVEL LADDER LENGTH
APPROX 8'-8" AND TOP LEVEL LADDER LENGTH APPROX 8'-0" (VERIFY
DIMENSIONS IN FIELD). SEE DETAIL . REVERSE SWING OF
EXISTING FLOOR HATCH TO SWING UPWARD AWAY FROM LADDER
(VERIFY IN FIELD).
PROVIDE ¾” FIRE-RETARDANT-TREATED, TONGUE AND GROOVE,
PLYWOOD SUBFLOOR OVERLAY, MECHANICALLY ATTACHED TO
EXISTING FLOOR PLANKS TO REMAIN AT HIGHEST FLOOR LEVEL,
APPROX 10’-0" X 10’-0" (VERIFY DIMENSIONS IN FIELD).
EXISTING WOOD RAILINGS TO REMAIN. REMOVE EXISTING WOOD
SUPPORTS BETWEEN BOTTOM OF RAILING AND ROOF. SAVE,
MODIFY HEIGHT AND REINSTALL WITH MEMBRANE SLIP-SHEET
BETWEEN BOTTOM OF SUPPORT AND ROOF MEMBRANE. PREPARE,
PRIME AND PAINT ALL SURFACES OF RAILINGS WITH HPC (VERIFY
LOCATIONS AND DIMENSIONS IN FIELD).
PROVIDE FABRICATED COPPER COPING CAPS AT EXISTING WOOD
RAILINGS. MECHANICALLY ATTACH AND SEAL AT END CONDITIONS
(VERIFY DIMENSIONS IN FIELD) SEE DETAIL .
PROVIDE FABRICATED COPPER CAPS AT EXISTING MASONRY
POSTS/PIERS. MECHANICALLY ATTACH (VERIFY DIMENSIONS IN
FIELD) SEE DETAIL .
PROVIDE COPPER DRIP-EDGE FASCIA. REPLACE DAMAGED/ROTTED
WOOD FASCIA AND SUB FASCIA, PREPARE, PRIME AND PAINT WITH
HPC (VERIFY DIMENSIONS IN FIELD) SEE DETAIL AND
EXTERIOR ELEVATION DRAWINGS.
PROVIDE CONTINUOUS SNOW GUARD SYSTEM. SEE DETAIL
DISCONNECT EXISTING DUCTWORK AND CONTROL WIRING.
REMOVE EXISTING SMOKE/HEAT VENT HATCH. PROVIDE
SMOKE/HEAT VENT HATCH, APPROXIMATE DIMENSIONS INDICATED
ON PLAN (VERIFY DIMENSIONS IN FIELD). PROVIDE
FLASHING/DIVERTER INTEGRAL TO METAL PANEL ROOF SYSTEM
PROFILE (VERIFY WITH ROOF PANEL MANUFACTURER), RECONNECT
EXISTING DUCTWORK AND CONTROL WIRING (VERIFY EXISTING
CONDITIONS IN FIELD) SEE DETAIL .
PROVIDE RADIUS METAL ROOF PANEL TO FOLLOW CURVED PROFILE
OF SUBSTRATE (VERIFY IN FIELD).
PROVIDE CONTINUOUS GUTTER AND DOWNSPOUTS. SEE DETAIL
AND EXTERIOR ELEVATION DRAWINGS.
EXISTING OCTAGONAL TOWER METAL ROOF TO REMAIN, PREPARE,
PRIME AND PAINT WITH HPC TO MATCH COLOR OF MAIN ROOF
METAL ROOF PANEL SYSTEM. SEE EXTERIOR ELEVATION
DRAWINGS.
PROVIDE METAL DRIP-EDGE FASCIA INTEGRAL TO METAL ROOF
PANEL SYSTEM. REPLACE DAMAGED/ROTTED WOOD FASCIA AND
SUB FASCIA, PREPARE, PRIME AND PAINT WITH HPC (VERIFY
DIMENSIONS IN FIELD) SEE DETAIL AND EXTERIOR
ELEVATION DRAWINGS.
PROVIDE RIDGE CAP TO MATCH METAL ROOF PANEL. SEE DETAIL
REMOVE EXISTING FABRICATED METAL DIVERTER. PROVIDE
FABRICATED METAL RAIN DIVERTER TO MATCH TO MATCH EXISTING
PROFILE, DIMENSIONS AND METAL ROOF PANEL FINISH.
PROVIDE METAL BASE FLASHING TO MATCH METAL ROOF PANEL,
COPPER COUNTER FLASHING AND SEALANT. TURN ICE AND WATER
SHIELD WATERPROOF UNDERLAYMENT MEMBRANE VERTICAL TO
TOP OF BASE FLASHING – TYPICAL. SEE DETAIL
PROVIDE 2X4 PTP WOOD BLOCKING RAIN DIVERTER WITH FULLY
ADHERED MEMBRANE AT ALL SURFACES FLASHED INTO ROOF
MEMBRANE. SEE DETAIL
PROVIDE TRANSITION BETWEEN METAL PANEL AND MEMBRANE
ROOF SYSTEMS. SEE DETAIL
EXISTING STAINLESS STEEL RAILING SUPPORT BAR TO REMAIN, TYP
Roof Key Notes
A. THE FOLLOWING CONDITIONS WERE OBSERVED DURING TEST CUT
ANALYSIS. THE CONTRACTOR IS REQUIRED TO VERIFY ALL EXISTING
CONDITIONS AND PROVIDE A COMPLETE REMOVAL OF ALL MATERIALS
ABOVE THE ROOF DECK AT LOCATIONS INDICATED. UNLESS NOTED
OTHERWISE. COORDINATE WITH ABATEMENT DRAWINGS.
B. TYPICAL AT ROOF CUT #1: (AT LOW-SLOPE BELL TOWER)
• AGGREGATE
• 2-PLY BUILT-UP ROOFING CAP SHEET – ADHERED
• 2-PLY BUILT-UP ROOFING BASE SHEET – MECHANICALLY ATTACHED
• ROSIN UNDERLAYMENT SHEET
• T&G WOOD PLANK DECK
C. TYPICAL AT ROOF CUT #2: (AT STEEP-SLOPE MAIN ROOF)
• METAL ROOF PANELS – MECHANICALLY ATTACHED (REMOVE)
• ROSIN PAPER - LOOSE LAID (REMOVE)
• GRANULATED ICE AND WATER SHIELD - ADHERED (REMOVE)
• 3/4" PLYWOOD (REMOVE)
• WOOD FURRING STRIPS (REMOVE)
• ASPHALT SHINGLES (REMOVE)
• ASPHALTIC FELTS (REMOVE)
• 3/4" HORIZONTAL WOOD SLATS (REMOVE)
• 2" TONGUE AND GROOVE WOOD DECK
Existing Conditions Notes
/4 AA191
/3 AA191
/5 AA191
/14 AA191
/7 AA191
/11 AA191
/12 AA191
/2 AA191
/6 AA191
/2 AA191
/10 AA191
/8 AA191
/13 AA191
/8 AA191
/2 AA191
/14 AA191
A. DO NOT SCALE DRAWINGS TO OBTAIN DIMENSIONS.
B. TAKE FIELD MEASUREMENTS TO FIT THE WORK PROPERLY. VERIFY
ALL EXISTING CONDITIONS AND DIMENSIONS IN THE FIELD.
C. REFER INCONSISTENCIES TO ARCHITECT PRIOR TO COMMENCING
THE WORK IN AFFECTED AREA.
D. ITEMS ARE SHOWN DIAGRAMMATICALLY ON DRAWINGS. VERIFY
SPACE REQUIREMENTS AND DIMENSIONS TO FIT THE WORK
PROPERLY.
E. NOTES SHOWN ON ONE DRAWING APPLY TO ALL SIMILAR
DRAWINGS.
F. DO NOT DISTURB CONSTRUCTION SUSPECTED OF CONTAINING
HAZARDOUS MATERIAL. IF ENCOUNTERED, IMMEDIATELY NOTIFY
ARCHITECT AND OWNER.
General Notes
A. DRAWINGS ARE REPRESENTATIVE, AND MAY NOT EXACTLY INDICATE
ALL FIELD CONDITIONS
B. VERIFY IN FIELD LOCATIONS OF ALL EXISTING ROOF DRAINS AND
PENETRATIONS PRIOR TO FIRST SUBMITTAL OF SHOP DRAWINGS.
C. INSPECT ROOF DECK PRIOR TO ROOFING INSTALLATION. VERIFY
THAT EXISTING MATERIALS ARE SOLID AND SECURE. NOTIFY
ARCHITECT IMMEDIATELY IF DETERIORATED OR LOOSE MATERIALS
ARE DISCOVERED.
D. PROVIDE COMPLETE ROOFING INSTALLATION. REPAIR ALL ITEMS NOT
SCHEDULED FOR WORK THAT ARE DAMAGED DURING ROOFING
WORK.
E. MAINTAIN WATERTIGHT CONDITIONS AT ALL TIMES.
F. PROVIDE ROOFING SYSTEMS AND ALL RELATED COMPONENTS
INDICATED BY THE CONTRACT DOCUMENTS.
G. WORK INCLUDES BUT IS NOT LIMITED TO REMOVAL OF ALL EXISTING
ROOFING MATERIALS UNLESS NOTED OTHERWISE. AT LOW-SLOPE
AREAS INCLUDING AGGREGATE, BUR MEMBRANES, FASTENERS,
FLASHINGS, CANTS, METAL FASCIAS AND FLASHINGS. AT STEEP
SLOPE AREAS INCLUDING METAL ROOF PANELS, SNOWGUARDS,
FASTENERS, UNDERLAYMENTS, TRIMS AND FLASHINGS DOWN TO
ROOF DECK. THOROUGHLY CLEAN ALL EXISTING SUBSTRATES
INCLUDING REMOVAL OF ALL FASTENERS AND ADHESIVES, PREPARE
AS REQUIRED TO ACCEPT ROOFING MATERIALS INDICATED.
H. REMOVE AND LEGALLY DISPOSE OF ALL MATERIALS INDICATED FOR
DEMOLITION.
I. REMOVE EXISTING ROOF AND HEAT/SMOKE HATCHES/VENTS.
DISCONNECT, TEMPORARILY SUPPORT AND RECONNECT EXISTING
DUCTWORK AND CONTROL WIRING AT HEAT/SMOKE HATCH/VENT.
VERIFY EXISTING OPENING DIMENSIONS AND PREPARE OPENINGS
PRIOR TO PROVIDING ROOF AND HEAT/SMOKE HATCHES/VENT
INSTALLATIONS.
J. EXTEND ALL EXISTING VENTS AS REQUIRED TO MAINTAIN MINIMUM
18" HEIGHT ABOVE SURFACE OF FINISHED ROOF (VIF).
K. WOOD BLOCKING SHALL BE PRESERVATIVE-TREATED (PTP). ALL
FASTENERS TO BE STAINLESS STEEL SCREW TYPE.
L. REMOVE EXISTING GUTTERS, DOWNSPOUTS AND ATTACHMENT
BRACKETS, HARDWARE AND FASTENERS. BEFORE BEGINNING
CONSTRUCTION, VERIFY ALL ROOF DRAINS ARE CLEAR AND IN
WORKING ORDER. REPORT ANY OBSTRUCTIONS TO ARCHITECT AND
OWNER PRIOR TO BEGINNING REMOVALS. PREPARE SUBSTRATES
PRIOR TO PROVIDING GUTTER AND DOWNSPOUT INSTALLATIONS.
M. SEE EXTERIOR ELEVATION DRAWINGS FOR WORK REQUIRED AT
EXTERIOR BUILDING ELEVATIONS INCLUDING, BUT NOT LIMITED TO:
WOOD REPLACEMENT, RESTORATION, PAINTING AND JOINT AND
CRACK SEALING.
N. SEE STRUCTURAL LOAD NOTES FOR WIND SPEED AND UPLIFT
PRESSURES.
O. COORDINATE ALL REMOVALS WITH HAZARDOUS MATERIAL
DRAWINGS
General Re-Roofing Notes
N
Date:Drawn By: Drawing Number:
Project No.:
A B
C D
E F
G H
I J
K L
M N
2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17
A B
C D
E F
G H
I J
K L
M N
Tetra Tech Engineers, Architects & Landscape Architects, P.C.
CLEAR SOLUTIONS
complex world
Key Plan N.T.S.
It is a v io la tio n of th e Ed uc at io n
La w o f t he S ta te o f N ew Y or k fo r a ny p er so n to a lte r o r m od ify th is d oc um en t i n an y w ay u nl es s ac tin g un de r t he d ire ct io n of a li ce ns ed a rc hi te ct
123174-23001.9 AA190
August 26, 2026
Roof Plan and Photos
TLG
Tompkins County Ithaca, NY
Daniel D. Tompkins Roof Project Alterations to:
1/4" = 1'-0"1 Roof Plan
Roof Legend
AREA OF NO WORK, UNLESS NOTED OTHERWISE
AREA OF TAPERED INSULATION (TYP). SEE ROOF PLAN.
AREA OF TAPERED INSULATION CRICKET
METAL PANEL ROOF SYSTEM
DIRECTION OF DOWNWARD SLOPE OF SLOPED STRUCTURE.
DIRECTION AND DEGREE OF DOWNWARD SLOPE OF TAPERED
INSULATION (MINIMUM 1/4"/FT, TYP AT EXISTING ROOF AREAS
UNO). SEE ROOF PLAN.
TOTAL THICKNESS OF INSULATION INCLUDING COVERBOARD. SEE
ROOF PLAN FOR TAPERED LAYOUTS
ROOF SYSTEM TYPE.
WALKWAY PAD (TYP).
PIPE PENETRATION (TYP).
ROOF HATCH
SMOKE/HEAT VENT HATCH
CONTINUOUS SNOWGUARD
TEST CUT LOCATION, REFER TO EXISTING CONDITIONS NOTES
T 1/4"
+X.X"
W
RS-X
(2011-05) arch-rflgnd
#X
RH
SV
STRU
SLOPE
NTS2 Photo 1 NTS3 Photo 2
NTS4 Photo 3 1/4" = 1'-0"5 Photo 4
CONT UNDERLAYMENT
STANDING SEAM
METAL ROOF SYSTEM
EXISTING WOOD
ROOF DECK
CLEAT
CONT EAVE TRIM
WITH DRIP EDGE,
OVERLAP 1" INTO
GUTTER
EXISTING WOOD ORNAMENTAL FRIEZE
BOARD TRIM, SOFFITS, FASCIAS,
CORNICE AND TRIM. REMOVE EXISTING
DETERIORATED MATERIALS AND
PROVIDE WOOD COMPONENTS TO
MATCH EXISTING PROFILES AND
DIMENSIONS. (TYPICAL AT EAVES)
PREPARE, PRIME AND PAINT ALL
EXPOSED SURFACES WITH HPC. SEE
EXTERIOR ELEVATION DRAWINGS FOR
MORE INFORMATION.
TURN UNDERLAYMENT
DOWN VERTICALLY 3" MIN
CONTINUOUS 6" HALF
ROUND COPPER GUTTER
SYSTEM AND
ACCESSORIES, RADIUS
CIRCLE BRACKET WITH
MOUNTING SHANK PLATE
AND SPRING CLIP.
MECHANICALLY ATTACH
WITH STAINLESS STEEL
LAG BOLTS PER
MANUFACTURE'S
REQUIREMENTS. PROVIDE
COPPER DOWNSPOUT TO
MATCH, WITH CONNECTOR
TO EXISTING DOWNSPOUT
BOOT AT GRADE
CONT SNOWGUARD SYSTEM
ROOF
SYSTEM
RS-2
FASTENER 12" OC
SLIDING ANCHOR
CLIP PER MFR REQ
6" MAX
THIS DETAIL IS TYPICAL AT RS-2,
DETAIL AT RS-3 IS SIMILAR
EXISTING
ABANDONED
INTERNAL
GUTTER TO
REMAIN
COVERED (VIF)
PROVIDE MULTIPLE
LAYERS OF PLYWOOD
AND SHIM AS REQ TO
ACHIEVE RADIUS, VIF
CONT PTP WOOD
BLOCKING, REMOVE EXG
MATERIALS, VERIFY
EXISTING CONDITIONS
AND DIMENSIONS IN FIELD
12" +/-
NOTE - VERIFY ALL SNOWGUARD LOCATIONS
AND ANCHORING WITH SNOWGUARD
MANUFACTURER AND SPECIFICATION.
ROOF
SYSTEM
RS-1
PROVIDE
WALKWAY PADS -
AT ACCESS SIDE
OF ROOF HATCH
INSULATED ROOF HATCH COVER WITH SKYLIGHT DOMES
ROOF INFORMATION DECAL
ADHERED TO INTERIOR FACE
OF ROOF HATCH CURB - TYP
SECURE MEMBRANE FLASHING TO
CURB WITH MECHANICALLY
FASTENED TERM BAR AND SEALANT
FACTORY FABRICATED INSULATED
CURB - FASTEN PER MANUF REQ
LADDER AT LATCH SIDE OF HATCH
SEAMS PER MANUF
PTP WOOD BLOCKING
CONT ISOLATION BARRIER BETWEEN
BLOCKING AND LT GAUGE METAL
EXISTING WOOD STRUCTURE, VIF
PROVIDE 42"
HIGH CURB
MOUNTED FALL
PROTECTION
RAILING
SYSTEM WITH
SELF-CLOSING
GATE
MECHANICALLY
ATTACHED TO
HATCH CURB
ROOF
SYSTEM
RS-1
VENT PIPE (SIZE VARIES,
REMOVE EXISTING FLASHING,
VIF)
STAINLESS STEEL CLAMPING
BAND (CUT OFF EXCESS STRAP)
PRE-MOLDED PIPE BOOT CUT
TO HEIGHT, BUT NO LOWER
THAN LAST REINFORCING RING
(NO WRINKLES OR FOLDS
UNDER CLAMPING RING)
CONT SEALANT
PROVIDE PREFABRICATED
VENT PIPE EXTENSION AT
EXISTING VENT PIPE
SEAMS PER MANUF REQ
VENT PIPE
1'
6"
PROVIDE METAL COLLAR
WHEN REQUIRED BY
ROOF SYSTEM
MANUFACTURER
30" X 30" WALKWAY PAD BY ROOF
MANUFACTURER. SPACE UNITS 1 1/2"
APART FROM EACH OTHER. ADHERE PAD
TO ROOF MEMBRANE PER
MANUFACTURER'S REQUIREMENTS
NOTE: PROVIDE WALKWAY PADS ON ROOF AT ROOF HATCH
ROOF SYSTEM
RS-1
ROOF
SYSTEM
RS-2
CONTINUOUS RIDGE CAP,
SEAM, PER MANF REQ,
FINISH TO MATCH ROOF
ZEE CLOSURE, SEAL AND
FASTEN PER MANF REQ
TAPE SEALANT
SEAL TURNED UP LEG
MIN
2"
MECHANICALLY FASTEN
ROOF PANELS TO
SUBSTRATE PER
MANUFACTURE'S
REQUIREMENTS
MIN
6"
ROOF
SYSTEM
RS-2
FABRICATED CRICKET, FASTEN PER
MANUFACTURER'S REQ FINISH TO
MATCH ROOF
ZEE CLOSURE WITH MODIFIED J-CHANNEL,
SEAL AND FASTEN PER MANUFACTURER'S
REQUIREMENTS
CONTINUOUS CLEAT, FASTENED PER
MANUFACTURER'S REQUIREMENTS
CURB FLASHING, FASTEN PER
MANUFACTURE'S REQUIREMENTS, FINISH TO
MATCH ROOF. SIM AT SIDES OF CURB
CURB FLASHING IS TO
MATCH PROFILE AND
RADIUS/CURVE OF
METAL ROOF PANEL,
VIF
(Sliding)
SELF ADHERING SHEET UNDERLAYMENT
LAP 12" MIN OVER ROOF MEMBRANE
3/4" FIRE-RETARDANT EXTERIOR GRADE
PLYWOOD MECHANICALLY ATTACHED
PER SPECIFIED REQUIREMENTS
STANDING SEAM METAL ROOF SYSTEM,
ATTACH WITH SLIDING CLIP PER MANUF REQ
CONT CLEAT SET IN CONT BED OF SEALANT
SEPARATION PLATE
FULLY ADHERED MEMBRANE PER MANUF REQ.
EXTEND MEMBRANE 12" MIN UP-SLOPE UNDER
SELF ADHERING UNDERLAYMENT MEMBRANE
AND METAL ROOF PANEL
BONDING ADHESIVE
FASTENERS AT 12" OC
ISOLATION BARRIER
2X4 PTP WOOD BLOCKING RAIN
DIVERTER MECHANICALLY
ATTACHED TO ROOF DECK
FULLY ADHERED MEMBRANE AT
ALL SURFACES FLASHED INTO
ROOF MEMBRANE
SEAMS PER MANUF REQ
EXISTING WOOD
DECK, VIF
(with Diverter)
ROOF
SYSTEM
RS-3
ROOF
SYSTEM
RS-2
M
IN
1 1/2"
12" +/-
CONT COPPER TRIM WITH DRIP EDGE,
PATCH TO MATCH EXISTING STUCCO
COLOR AND TEXTURE
CONT SAW-CUT WITH REGLET AND SEALANT
FORMED COPPER COUNTER FLASHING
FULLY ADHERED MEMBRANE FLASHING
WITH TERMINATION BAR AND SEALANT -
FASTEN PER MFR REQ
ROOF
SYSTEM
RS-3
EXISTING WALL
CONSTRUCTION, VIF
SEAMS PER MFR REQ
8" M
IN
, V
IF
NOTE - AT WINDOW LOCATION TERMINATE
FLASHING TO FOLLOW PROFILE OF WINDOW
OPENING, VIF.
DOUBLE SLOPE FORMED
COPPER COPING SYSTEM,
MECHANICALLY FASTEN WITH
CONCEALED CLEATS AND
FASTENERS TO EXISTING
WOOD RAILING CAP
CONT ISOLATION BARRIER
LAP OVER TOP OF
EXISTING RAILING CAP
EXISTING WOOD
RAILING SYSTEM, SEE
EXTERIOR ELEVATION
DRAWINGS FOR MORE
INFORMATION
VIF
9 1/2" +/-
POLYISOCYANURATE ROOF INSULATION: MULTIPLE
LAYERS WITH STAGGERED JOINTS, BEAD ADHERED
TO SUBSTRATE BOARD PER SPECIFIED
REQUIREMENTS. REFER TO ROOF PLANS FOR
INSULATION THICKNESS AND LOCATIONS OF
TAPERED INSULATION
1/2" HIGH DENSITY POLYISOCYANURATE COVER
BOARD: BEAD ADHERED TO INSULATION PER
SPECIFIED REQUIREMENTS
SINGLE-PLY TPO MEMBRANE:
SEAMED AND ADHERED TO COVER BOARD PER
ROOF SYSTEM MANUFACTURER'S REQUIREMENTS
EXISTING WOOD DECK AND STRUCTURE TO REMAIN -
REMOVE ALL EXISTING ROOFING MATERIALS,
BLOCKING AND FASTENERS. CLEAN ROOF DECK OF
ALL DEMOLITION DEBRIS.
UNCONDITIONED 1/4"/FT TAPERED
INSULATION FOR DRAINAGE ONLY RS-1
STANDING SEAM METAL ROOF SYSTEM,
ATTACH PER MANUFACTURER'S
REQUIREMENTS TO ACHIEVE CLASS UL90
WIND UPLIFT RESISTANCE CLASSIFICATION
CONTINUOUS SELF ADHERING SHEET
UNDERLAYMENT AT ALL ROOF AREAS.
TERMINATE VERTICAL 8" MINIMUM AT ALL WALL,
PENETRATION AND EDGE LOCATIONS.
ANCHOR CLIP AND BEARING PLATE SIZED AND
LOCATED AS REQUIRED BY ROOF SYSTEM
MANUFACTURER. MECHANICALLY ATTACHED TO
WOOD DECK.
NOTE:
FASTENERS ARE TO PENETRATE TOP OF DECK ONLY.
LENGTH IS NOT TO PROJECT BEYOND BOTTOM.
EXISTING WOOD DECK AND
STRUCTURE TO REMAIN.
REMOVE ALL EXISTING
ROOFING MATERIALS,
BLOCKING AND FASTENERS,
CLEAN ROOF DECK OF ALL
DEMOLITION DEBRIS
12 +/-, VIF
RS-2
3/4" FIRE-RETARDANT EXTERIOR GRADE
PLYWOOD MECHANICALLY ATTACHED PER
SPECIFIED REQUIREMENTSSINGLE-PLY TPO MEMBRANE:
SEAMED AND ADHERED TO COVER BOARD PER
ROOF SYSTEM MANUFACTURER'S REQUIREMENTS
EXISTING WOOD DECK, VIF
12 +/-, VIF
RS-3
3/4" FIRE-RETARDANT EXTERIOR GRADE
PLYWOOD MECHANICALLY ATTACHED PER
SPECIFIED REQUIREMENTS. PREPARE AND
PRIME AS REQUIRED BY MEMBRANE
MANUFACTURE 5/8" SUBSTRATE BOARD MECHANICALLY ATTACHED
PER SPECIFIED REQUIREMENTS CUT AS REQUIRED
TO FOLLOW PROFILE OF STRUCTURE
EXISTING INSULATION, VIF
EXISTING INSULATION, VIF
VE
R
IF
Y
IN
F
IE
LD
8' -0
CORRUGATED
ALUMINUM RUNGS,
EQUAL SPACES AT
12" OC
ALUMINUM WALL
BRACKET - TYPICAL
ALUMINUM STRINGER
7"
VI
F
1'
0" 6"
1'
0" T
YP
EPOXY ANCHORS
NOTE: - ALL ALUMINUM TO BE MILL FINISH
- ALL OPEN TUBE ENDS TO BE CAPPED/SEALED CLOSED
- VERIFY LADDER HEIGHT IN FIELD PRIOR TO FABRICATION
- ALL JOINTS AND CONNECTIONS TO BE FULLY WELDED
- SEE SPECIFICATION SECTION 05 50 00 FOR MORE
INFORMATION
ALIGN TOP RUNG WITH
TOP OF ROOF SURFACE
1' - 6"
ALIGN TOP OF
SIDERAILS WITH TOP
OF ROOF HATCH CURB
ALUMINUM
BRACKET
ATTACHED TO 2X6
FLOOR SLEEPER
FLOOR
FROM BELL TOWER FLOOR TO ROOF HATCH
1 1/2" MIN. OVERLAP FULLY
ADHERED FIELD MEMBRANE
ON MASONRY, FASTEN TO
BLKG PER MANUF REQ
4-WAY SLOPED FABRICATED
COPPER CAP SYSTEM
(2) LAYERS OF 2X PTP WOOD
BLOCKING ADHERED AND
MECHANICALLY ATTACHED TO
EXISTING MASONRY
CONT ISOLATION BARRIER
LAP OVER TOP AND SIDES
OF MASONRY POST CAP
EXISTING MASONRY POST AND
CAP
VIF
2'-0" +/-
SNOW GUARD
MECHANICALLY
ATTACHED EVERY 16" OC
TO STANDING SEAM
METAL ROOF SEAM PER
MANUFACTURER'S
REQUIREMENTS
ROOF
SYSTEM
RS-2
NOTE - VERIFY ALL SNOW
GUARD LOCATIONS AND
ANCHORING WITH SNOW
GUARD MANUFACTURE
AND SPECIFICATIONS
6"
ROOF
SYSTEM
RS-3
NOTE - VERIFY ALL SNOW GUARD LOCATIONS
AND ANCHORING WITH SNOW GUARD
MANUFACTURER AND SPECIFICATIONS
NOTE - DETAIL IS
EXPLODED FOR CLARITY
STAINLESS STEEL BASE
PLATE AND FASTENERS
EXTRUDED ALUMINUM
BRACKET WITH
STAINLESS STEEL
FASTENERS
CONT TWO PIPE SNOW
GUARD SYSTEM
FULLY ADHERED
MEMBRANE FLASHING
AND SEALANT
CONTINUOUS FULLY
ADHERED FIELD MEMBRANE
WATER CUT-OFF
MASTIC BETWEEN
BRACKET AND
MEMBRANE WITH
CONTINUOUS SEALANT
AT ALL PERIMETERS
CONT COPPER TRIM WITH DRIP EDGE,
PATCH TO MATCH EXISTING STUCCO
COLOR AND TEXTURE
CONT SAW-CUT WITH REGLET AND SEALANT
FORMED COPPER COUNTER FLASHING
FULLY ADHERED MEMBRANE FLASHING
FOLLOWING PROFILE OF INTEGRAL
GUTTER ONTO ADJACENT ROOF SYSTEM
WITH TERMINATION BAR AND SEALANT -
FASTEN PER MFR REQ
ROOF
SYSTEM
RS-3
EXISTING WALL
CONSTRUCTION, VIF
SEAMS PER MFR REQ
ROOF SYSTEM MEMBRANE
OVER FORMED 22 GAUGE
GALVALUME METAL INTEGRAL
GUTTER, TO MATCH EXISTING,
SLOPED TO NORTH, FASTEN
TO EXISTING WOOD DECK AND
SUBSTRATE.
PTP WOOD
BLOCKING AND
PLYWOOD AS
REQUIRED
EXISTING WOOD
STRUCTURE, VIF
8" M
IN
, V
IF
VE
R
IF
Y
IN
F
IE
LD
8' -8
CORRUGATED
ALUMINUM RUNGS,
EQUAL SPACES AT
12" OC
ALUMINUM WALL
BRACKET - TYPICAL
ALUMINUM STRINGER
3"
8" 4'
0"
M
AX
7"
8" 6"
1'
0" T
YP
EPOXY ANCHORS, TYP
NOTE: -ALL ALUMINUM TO BE MILL FINISH
-ALL OPEN TUBE ENDS TO BE CAPPED/SEALED CLOSED
-VERIFY LADDER HEIGHT IN FIELD PRIOR TO FABRICATION
- ALL JOINTS AND CONNECTIONS TO BE FULLY WELDED
- SEE SPECIFICATION SECTION 05 50 00 FOR MORE
INFORMATION
ALIGN TOP RUNG WITH
HIGHPOINT OF LANDING
1' - 5 15/16"
FROM TOP OF STAIR TO BELL TOWER FLOOR
VI
F
EX
TE
R
IO
R W
AL
L VI
F
C M
U O
R C
FM
F
CUT AND SMOOTH GRIND
EXCESS LENGTH FLUSH WITH
NUT, TYP
3/8" SS THREADED ROD AND
SS WASHER, CHEMICAL
ANCHOR WITH SS SCREEN
TUBE FOR HOLLOW MASONRY
EMBED 3 3/8"
ISOLATION BARRIER
MEMBRANE, TYP
LADDER OR STEPS
BRACKET
VERIFY EXISTING
CONDITIONS IN FIELD
EXISTING STUCCO
COATING, VIF
EXISTING BRICK
WALL, VIF
URETHANE SEALANT, COLOR TO MATCH
EXISTING ADJACENT STUCCO FINISH.
BROADCAST SILICA SAND INTO THE APPLIED
SEALANT IMMEDIATELY AFTER TOOLING TO
ACHIEVE A ROUGHENED TEXTURE.
BOND BREAKER (BACKER ROD OR
TAPE, PER SEALANT MFR REQ
ROOF
SYSTEM
RS-2
CONT GABLE TRIM AND
CLEAT WITH DRIP EDGE,
PER MANF REQ
CLOSURE, PER MANF REQ
EXG DECORATIVE
FASCIA BOARD, VIF,
SEE EXTERIOR
ELEVATION
DRAWINGS FOR
MORE INFORMATION
ROOF
SYSTEM
RS-3
CONT GABLE TRIM AND CLEAT
WITH DRIP EDGE, PER MANF REQ
CLOSURE, PER
MANF REQ
EXG DECORATIVE
FASCIA BOARD, VIF,
SEE EXTERIOR
ELEVATION
DRAWINGS FOR
MORE INFORMATION
LAP MEMBRANE OVER
ROOF EDGE
CONT SEALANT
ROOF
SYSTEM
RS-1
CONT FUESED FASCIA
TRIM WITH DRIP EDGE,
FASTEN PER MFR REQ
SEAM, PER MANF REQ
EXG DECORATIVE
FASCIA BOARD, VIF,
SEE EXTERIOR
ELEVATION
DRAWINGS FOR
MORE INFORMATION
LAP MEMBRANE OVER
ROOF EDGE
2X6 PTP WOOD
BLOCKING LAYERS AS
REQUIRED TO MATCH
INSULATION
THICKNESS, SEE PLAN
OVERLAP MEMBRANE AND
FASCIA TRIM 1 1/2" ON EXISTING
FASCIA BOARD AND FASTEN PER
MFR REQ
Date:Drawn By: Drawing Number:
Project No.:
A B
C D
E F
G H
I J
K L
M N
2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17
A B
C D
E F
G H
I J
K L
M N
Tetra Tech Engineers, Architects & Landscape Architects, P.C.
CLEAR SOLUTIONS
complex world
It is a v io la tio n of th e Ed uc at io n
La w o f t he S ta te o f N ew Y or k fo r a ny p er so n to a lte r o r m od ify th is d oc um en t i n an y w ay u nl es s ac tin g un de r t he d ire ct io n of a li ce ns ed a rc hi te ct
123174-23001.9 AA191
August 26, 2026
Details
TLG
Tompkins County Ithaca, NY
Daniel D. Tompkins Roof Project Alterations to:
1 1/2" = 1'-0"2 Eave Detail (Sliding)
1 1/2" = 1'-0"3 Roof Hatch Curb Detail
1 1/2" = 1'-0"4 Roof Vent Pipe Detail
1 1/2" = 1'-0"5 Walkway Pad Detail
1 1/2" = 1'-0"10 Ridge Detail (Fixed)
1 1/2" = 1'-0"6 Smoke/Heat Vent Hatch Flashing Detail
1 1/2" = 1'-0"8 Roof System Transition Detail (Sliding)
1 1/2" = 1'-0"14 Base Flashing Detail
3" = 1'-0"11 Railing Coping Cap Detail
1 1/2" = 1'-0"1 Roof System Details
3/4" = 1'-0"7 Clear Span Aluminum Ladder Detail
1 1/2" = 1'-0"12 Masonry Cap Detail
3" = 1'-0"13 Snow Guard Detail at Metal Roof System
1 1/2" = 1'-0"9
Snow Guard Detail at Membrane Roof System
1 1/2" = 1'-0"15
Base Flashing Detail At Integral Slopped Gutter
3/4" = 1'-0"16 Wall Mounted Aluminum Ladder Detail
1 1/2" = 1'-0"17
Typical Aluminum Ladder Attachment Detail
NTS18 Stucco Crack Repair Detail
1 1/2" = 1'-0"19 Gable Detail at Metal Roof System
1 1/2" = 1'-0"20 Gable Detail at Membrane Roof System
1 1/2" = 1'-0"21 Roof Edge detail
9 TYP ALL 4 SIDES
2 2 2 2
5 5 5 5 5
10 TYP
9 TYP ALL 4 SIDES
5 56
2 2 2 2
3 3
5 5 5 5 5 5
12 12
PARTIAL EAST ELEVATION AT
BELL TOWER IS HIDDEN.
NOTES AT SOUTH, WEST, AND
NORTH ELEVATIONS ARE
TYPICAL AT EAST ELEVATION.
9TYP ALL 4 SIDES
10TYP
A. NOTES DESCRIBED ON ONE ELEVATION APPLY TO ALL ELEVATIONS,
TYPICAL UNLESS OTHERWISE NOTED.
General Elevation Notes
A. DO NOT SCALE DRAWINGS TO OBTAIN DIMENSIONS.
B. TAKE FIELD MEASUREMENTS TO FIT THE WORK PROPERLY. VERIFY
ALL EXISTING CONDITIONS AND DIMENSIONS IN THE FIELD.
C. REFER INCONSISTENCIES TO ARCHITECT PRIOR TO COMMENCING
THE WORK IN AFFECTED AREA.
D. ITEMS ARE SHOWN DIAGRAMMATICALLY ON DRAWINGS. VERIFY
SPACE REQUIREMENTS AND DIMENSIONS TO FIT THE WORK
PROPERLY.
E. NOTES SHOWN ON ONE DRAWING APPLY TO ALL SIMILAR
DRAWINGS.
F. DO NOT DISTURB CONSTRUCTION SUSPECTED OF CONTAINING
HAZARDOUS MATERIAL. IF ENCOUNTERED, IMMEDIATELY NOTIFY
ARCHITECT AND OWNER.
General Notes
PROVIDE CONTINUOUS GUTTER AT LOCATIONS OF EXISTING
REMOVED GUTTERS.
PROVIDE DOWNSPOUT AND REQUIRED OFFSETS AND STAND-
OFF BRACKETS AND TRANSITION CONNECTED TO EXISTING
STORM SEWER AT LOCATIONS OF EXISTING REMOVED
DOWNSPOUTS. PROVIDE DOWNSPOUT CONNECTOR WITH
OVERFLOW PROTECTION. PREPARE, PRIME, AND PAINT EXPOSED
SURFACES OF EXISTING STORM SEWER PIPE BLACK.
PREPARE, PRIME AND PAINT WITH HPC EXISTING WOOD
ORNAMENTAL FRIEZE BOARD TRIM, SOFFITS AND FASCIAS AND
RAILINGS (TYPICAL AT GABLES, THREE OCTAGONAL TOWERS
AND BELL TOWER).
EXISTING WOOD ORNAMENTAL FRIEZE BOARD TRIM, SOFFITS,
FASCIAS, CORNICE AND TRIM. REMOVE EXISTING DETERIORATED
MATERIALS AND PROVIDE WOOD COMPONENTS TO MATCH
EXISTING PROFILES AND DIMENSIONS. PREPARE, PRIME AND
PAINT ALL EXPOSED SURFACES WITH HPC (TYPICAL AT EAVES).
SEE KEY NOTE 14 ON ELEVATIONS FOR SPECIFIC AREAS
IDENTIFIED FOR REPLACEMENT. INSPECT ALL AREAS IN FIELD.
SEE PHOTOS AND .
REPAIR/RESTORE, PREPARE, PRIME AND PAINT WITH HPC, AND
SEAL PERIMETERS, AT EXISTING WOOD ORNAMENTAL ½ ROUND
PENDANTS (TYPICAL AT FIRST FLOOR WINDOW AND DOOR HEAD
END CONDITIONS). SEE PHOTO
REPAIR/RESTORE, PREPARE, PRIME AND PAINT WITH HPC, AND
SEAL PERIMETERS, AT EXISTING WOOD ORNAMENTAL DOOR
FRAME (TYPICAL AT NORTH AND SOUTH DOORS). SEE PHOTOS
AND
REMOVE EXISTING STEEL ORNAMENTAL GRILLE AND SIGN OVER
DOOR, PREPARE, PRIME AND PAINT WITH HPC AND REINSTALL
AFTER COMPLETION OF WORK. SEE PHOTO
EXISTING ANNUNCIATOR AND/OR SECURITY CAMERA TO REMAIN.
PROTECT FROM DAMAGE.
REMOVE EXISTING NYLON MESH AT INTERIOR OF (FOUR)
EXISTING LOUVERS (APPROX. 6’-0" X 16’-0" +/-, VERIFY
DIMENSIONS IN FIELD). PROVIDE 19GA GALVANIZED STEEL WIRE
MESH WITH 1/2" SQUARE OPENING. LAP A MINIMUM 6 INCHES.
MECHANICALLY ATTACHED AT INTERIOR TO COVER ENTIRE
LOUVER OPENINGS WITH NO VOIDS.
PROVIDE FABRICATED COPPER CAPS. SEE ROOF PLAN.
PROVIDE METAL ROOF SYSTEM AND SNOWGUARDS. SEE ROOF
PLAN.
PREPARE, PRIME AND PAINT WITH HPC TO MATCH COLOR OF
MAIN ROOF METAL ROOF PANELS. SEE ROOF PLAN.
EXISTING CRACK, SEAL. SEE DETAIL
AREA OF DETERIORATED MATERIAL REMOVAL AND
REPLACEMENT, VIF. SEE ELEVATION KEY NOTE 4.
Elevation Key Notes
/5 AA200 /6 AA200
/7 AA200
/8 AA200
/8 AA200 /9 AA200
13 /18 AA191
N
Date:Drawn By: Drawing Number:
Project No.:
A B
C D
E F
G H
I J
K L
M N
2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17
A B
C D
E F
G H
I J
K L
M N
Tetra Tech Engineers, Architects & Landscape Architects, P.C.
CLEAR SOLUTIONS
complex world
Key Plan N.T.S.
It is a v io la tio n of th e Ed uc at io n
La w o f t he S ta te o f N ew Y or k fo r a ny p er so n to a lte r o r m od ify th is d oc um en t i n an y w ay u nl es s ac tin g un de r t he d ire ct io n of a li ce ns ed a rc hi te ct
123174-23001.9 AA200
August 26, 2026
Exterior Elevations and Photos
TLG
Tompkins County Ithaca, NY
Daniel D. Tompkins Roof Project Alterations to:
1/8" = 1'-0"1 West Elevation 1/8" = 1'-0"3 North Elevation
1/8" = 1'-0"4 East Elevation 1/8" = 1'-0"2 South Elevation
NTS5 Photo 5
NTS6 Photo 6
NTS7 Photo 7
NTS8 Photo 8
NTS9 Photo 9
| G001 - Title Sheet and Symbols and Abbreviations |
| Sheets |
| G001 - Title Sheet and Symbols and Abbreviations |
| AH100 - Abatement Plan |
| Sheets |
| AH100 - Abatement Plan |
| AA190 - Roof Plan and Photos |
| Sheets |
| AA190 - Roof Plan and Photos |
| AA191 - Details |
| AA200 - Exterior Elevations and Photos |
| AH100 - Abatement Plan |
| AA191 - Details |
| Sheets |
| AA190 - Roof Plan and Photos |
| AA191 - Details |
| AA200 - Exterior Elevations and Photos |
| AH100 - Abatement Plan |
| AA200 - Exterior Elevations and Photos |
| Sheets |
| AA190 - Roof Plan and Photos |
| AA191 - Details |
| AA200 - Exterior Elevations and Photos |
| AH100 - Abatement Plan |
File details come from the government source that posted it. Updated .