J8217165 - USDA ERRC Limited Asbestos and Lead Paint Survey_Final to Client_3AUG21.pdf
PDF 813 KB Posted
- Attached to
- Main Building Chemical Wing Roof Replacement
- Solicitation number
- 12305b22R0009
About this file
This solicitation is for roof replacement services for the Main Building Chemical Wing at the United States Department of Agriculture Agricultural Research Service Eastern Regional Research Center. The solicitation seeks a firm-fixed price order for repairs to existing rafters and roof decking; replacement of the existing roof membrane and associated flashing and roof accessories; and installation of penthouse metal wall panels. The period of performance is 60 days from receipt of the notice to proceed. Bid, payment, and performance bonds are required. The set-aside is for woman-owned small businesses with a size standard of $16.5 million or less. The NAICS code is 238160 and the magnitude of construction is between $1 million and $5 million. Questions regarding the solicitation must be submitted in writing by July 5, 2022. Answers will be provided in an amendment.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| SF30 Amendment 2.pdf | ||
| UFGS Fluid Applied Air Barrier.pdf | ||
| RFI 2.docx | DOCX document | |
| RFI 1 Response.docx | DOCX document | |
| SF30.pdf | ||
| Wage Determination PA20220099 02252022.pdf | ||
| 12305B22R0009.pdf | ||
| Specifications.pdf | ||
| Wyndmoor Dwg.pdf | ||
| SOW 8APR2022 Chemical Wing Roof Replacement ERRC PA.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Limited Asbestos and Lead Paint Survey Report
USDA Eastern Region Research Center (ERRC)
600 East Mermaid Lane Wyndmoor, PA
August 3, 2021
Terracon Project No. J8217165
Prepared for:
The Johnson-McAdams Firm PA
Collierville, Tennessee
Prepared by:
Terracon Consultants, Inc.
Blue Bell, Pennsylvania
Terracon Consul tants, Inc. 325 Sentry Parkway, Build ing 5W, Sui te 200 Blue Bel l, Pennsylvania 19422 P 267-512-7050 F 267-512-7055 terracon.com
August 3, 2021
The Johnson-McAdams Firm PA 340 Poplar View Lane, Suite 4 Collierville, TN 38017-3439
Attn: Mr. Jerry Martin P: (901) 604-4817 E: jerry.martin@jmcfirm.com
Re: Limited Asbestos and Lead Paint Survey Report USDA Eastern Region Research Center (ERRC) 600 East Mermaid Lane Wyndmoor, Pennsylvania Terracon Job No. J8217165
Dear Mr. Martin:
The purpose of this report is to present the results of a limited asbestos and lead paint survey performed on June 25, 2021 within the attic area and roof located at the above-referenced address.
This survey was conducted in general accordance with our proposal dated June 15, 2021. We understand that this survey was requested due to the planned repairs associated with a previous roof leak.
Asbestos was identified in samples collected at the subject site. Please refer to the attached report for details.
Lead was detected in paint at or above the EPA threshold for lead paint at the subject site. Please refer to the attached report for details.
Terracon appreciates the opportunity to provide this service to The Johnson-McAdams Firm PA. If you have any questions regarding this report, please contact the undersigned at (267) 512-7050.
Sincerely, Terracon Consultants, Inc.
Amanda M. Ege Tom Holley, CHMM, CIH, CSP Senior Staff Scientist Authorized Project Reviewer amege Typewriter for
Responsive ■ Resourceful ■ Reliable
TABLE OF CONTENTS
1.0 INTRODUCTION
2.0 BUILDING DESCRIPTION
3.0 FIELD ACTIVITIES - ASBESTOS
3.1 Visual Assessment
3.2 Physical Assessment
3.3 Sample Collection
3.4 Sample Analysis
4.0 REGULATORY OVERVIEW - ASBESTOS
5.0 FINDINGS AND RECOMMENDATIONS - ASBESTOS
6.0 FIELD ACTIVITIES – LEAD PAINT
6.1 Visual observation
6.2 Visual Assessment
6.3 Sample Analysis
7.0 REGULATORY OVERVIEW – LEAD PAINT
8.0 FINDINGS AND RECOMMENDATIONS – LEAD PAINT
9.0 LIMITATIONS/GENERAL COMMENTS
APPENDIX A ASBESTOS SURVEY SAMPLE SUMMARY
APPENDIX B LEAD PAINT SURVEY SAMPLE SUMMARY
APPENDIX C ANALYTICAL LABORATORY DATA
APPENDIX D LICENSES AND CERTIFICATIONS
APPENDIX E PHOTOS
Responsive ■ Resourceful ■ Reliable 1
LIMITED ASBESTOS AND LEAD PAINT SURVEY REPORT
USDA Eastern Region Research Center (ERRC)
Wyndmoor, Pennsylvania Terracon Project No. J8217165
August 3, 2021
1.0 INTRODUCTION
Terracon conducted a limited asbestos and lead paint survey of the roof and attic area utilized for mechanical equipment of the building located at 600 East Mermaid Lane in Wyndmoor, Pennsylvania. The survey was conducted on June 25, 2021 by Terracon’s Ms. Amanda Ege in accordance with Terracon’s proposal number PJ8217165 dated June 15, 2021. Interior building components and the roof were surveyed and homogeneous areas of suspect asbestos-containing materials (ACM) and lead paint (LP) were visually identified and documented. Although reasonable effort was made to survey accessible suspect materials, additional suspect but un-sampled materials could be located in walls, in voids, below the ground or in other concealed areas. Suspect ACM samples were collected in general accordance with the sampling protocols outlined in EPA regulation 40 CFR 763 (Asbestos Hazard Emergency Response Act, AHERA). Asbestos samples were delivered to an accredited laboratory for analysis. Suspect ACM samples were analyzed by Polarized Light Microscopy. An X-ray fluorescence (XRF) analyzer to measure the lead content of various painted components throughout the building.
2.0 BUILDING DESCRIPTION
For the purpose of this survey, the site consists only of the roof and attic area utilized for mechanical equipment of the building located at 600 East Mermaid Lane. It is Terracon’s understanding that the roof was not included in this survey and did not include the roof membrane or other roofing materials. . It is our understanding that repairs associated with a previous roof leak are proposed in these areas.
3.0 FIELD ACTIVITIES - ASBESTOS
The survey was conducted by Ms. Amanda M. Ege, a Commonwealth of Pennsylvania licensed asbestos inspector. A copy of Ms. Ege’s asbestos inspector certification is attached as Appendix D. The survey was conducted in general accordance with the sample collection protocols established in USEPA 40 CFR Part 763 Subpart E 763.86, AHERA. A summary of survey activities is provided below.
Limited Asbestos and Lead Paint Survey Report USDA Eastern Region Research Center (ERRC) ■ Wyndmoor, PA August 3, 2021 ■ Terracon Project No. J8217165
Responsive ■ Resourceful ■ Reliable 2
3.1 Visual Assessment
Survey activities were initiated with visual observation of the accessible areas of the roof and attic area utilized for mechanical equipment to identify homogeneous areas of suspect ACM. A homogeneous area (HA) consists of building materials that appear similar throughout in terms of color and texture with consideration given to the date of application.
3.2 Physical Assessment
A physical assessment of each homogeneous area (HA) of suspect ACM was conducted to assess the friability and condition of the materials. A friable material is defined by the USEPA as a material which can be crumbled, pulverized or reduced to powder by hand pressure when dry.
Friability was assessed by physically touching suspect materials.
3.3 Sample Collection
Based on results of the visual observation, bulk samples of suspect ACM were collected in general accordance with USEPA AHERA sampling protocols. Samples of suspect materials were collected from randomly selected locations in each homogeneous area. Bulk samples were collected using wet methods as applicable to reduce the potential for fiber release. Samples were placed in sealable containers and labeled with unique sample numbers using an indelible marker.
The selection of sample locations and frequency of sampling were based on Terracon’s observations and the assumption that like materials in the same area are homogeneous in content.
Terracon collected a total of 15 bulk samples from five (5) homogeneous areas of suspect ACM.
3.4 Sample Analysis
Bulk samples were submitted under chain of custody to EMSL Analytical, Inc. of Plymouth Meeting, Pennsylvania for analysis by PLM with dispersion staining techniques per USEPA methodology 600/R-93/116. The percentage of asbestos, where applicable, was determined by microscopic visual estimation. EMSL Analytical, Inc. (EMSL) is accredited under the National Voluntary Laboratory Accreditation Program (NVLAP), accreditation number 200699-0.
4.0 REGULATORY OVERVIEW - ASBESTOS
The asbestos NESHAP (40 CFR Part 61, Subpart M) regulates asbestos fiber emissions and asbestos waste disposal practices. The asbestos NESHAP regulation also requires the identification and classification of existing ACM according to friability prior to demolition or
August 3, 2021 ■ Terracon Project No. J8217165
Responsive ■ Resourceful ■ Reliable 3 renovation activity. Friable ACM is a material containing more than 1% asbestos that, when dry, can be crumbled, pulverized or reduced to powder by hand pressure. All friable ACM is considered as a regulated asbestos-containing material (RACM).
The asbestos NESHAP regulation classifies ACM as either RACM, Category I non-friable ACM or Category II non-friable ACM. RACM includes all friable ACM, along with Category I and Category II non-friable ACM that has become friable, will be or has been subjected to sanding, grinding, cutting or abrading, or ACM that has a high probability of becoming or has become crumbled, pulverized, or reduced to powder in the course of renovation or demolition activity.
Category I non-friable ACM are exclusively asbestos-containing packings, gaskets, resilient floor coverings, resilient floor covering mastics and asphalt roofing products that contain more than 1% asbestos. Category II non-friable ACM are all other non-friable materials other than Category I non-friable ACM that contain more than 1% asbestos. Category II non-friable ACM generally includes but is not limited to cementitious material such as: cement pipes, cement siding, cement panels, glazing, mortar and grouts.
In the Commonwealth of Pennsylvania, the federal NESHAP regulation has been delegated to the Pennsylvania Department of Environmental Protection (PADEP) air quality program. NESHAP pre-renovation and pre-demolition notifications (where >160 square feet/260 linear feet of any ACM are removed) must be submitted to the PADEP at least 10 business days prior to project commencement. Please note that demolition of any structure, which is defined as removal of a load-bearing member, requires a 10-day notification even when no asbestos is present.
In the Commonwealth of Pennsylvania, asbestos abatement activities are also regulated by the Pennsylvania Department of Labor and Industry (PADL&I). The PADL&I requires notifications at least five (5) working days prior to the commencement of asbestos abatement activities for asbestos renovations, demolitions or encapsulation of friable materials (RACM) on indoor projects. Asbestos abatement must be performed by a Pennsylvania-licensed Asbestos Abatement Contractor using a Pennsylvania-accredited Asbestos Contractor/Supervisor and Pennsylvania-accredited workers. Project Designs, if obtained, must be prepared by a Pennsylvania-accredited Asbestos Project Designer. Third-party air monitoring during abatement, if conducted, must be performed by a Pennsylvania-accredited Asbestos Inspector.
The United States Occupational Safety and Health Administration (USOSHA) asbestos standard for construction (29 CFR 1926.1101) regulates workplace exposure to asbestos. The USOSHA standard requires that employee exposure to airborne asbestos must not exceed 0.1 fibers per cubic centimeter of air (0.1 f/cc) as an eight-hour time weighted average (TWA) and not exceed
1.0 fibers per cubic centimeter of air (1.0 f/cc) over a 30-minute time period known as an excursion limit (EL). The TWA and EL are known as USOSHA’s asbestos permissible exposure limits (PELs). The USOSHA standard classifies construction and maintenance activities which could disturb ACM and specifies work practices and precautions which employers must follow when engaging in each class of regulated work.
August 3, 2021 ■ Terracon Project No. J8217165
Responsive ■ Resourceful ■ Reliable 4
5.0 FINDINGS AND RECOMMENDATIONS - ASBESTOS
Asbestos (5% chrysotile) was detected by laboratory analysis and determined to be present in the black window caulk located on the exterior windows on the roof (approximately 100 lf).
Asbestos (5% chrysotile) was detected by laboratory analysis and determined to be present in the grey window caulk located on the exterior windows on the roof (approximately 200 lf)
Asbestos (10% chrysotile) was detected by laboratory analysis and determined to be present in the light grey window caulk located on the exterior windows on the roof (approximately 200 sf).
Asbestos (3-4% chrysotile) was detected by laboratory analysis and determined to be present in the window glazing located on the interior windows within the attic area (approximately 350 lf).
If any additional materials not sampled as part of this survey are later revealed during the course of renovation activities, work should immediately cease until the material is sampled by an accredited asbestos inspector and laboratory analysis can confirm or deny asbestos-content.
An asbestos survey sample summary is included in Appendix A. Laboratory analytical reports are included as Appendix C. Photos are included of identified ACMs in Appendix E.
6.0 FIELD ACTIVITIES – LEAD PAINT
The survey was conducted on June 25, 2021 by Commonwealth of Pennsylvania accredited Lead Inspector Ms. Amanda Ege (License #005611). A summary of survey activities is provided below.
6.1 Visual observation
Our survey activities began with visual observation of areas to identify apparent unique combinations of suspect lead paint (LP). A unique combination of paint is based on paint color, building component and substrate. Assessment was conducted throughout visually accessible interior areas of the first floor and basement levels of the site building.
6.2 Visual Assessment
A visual assessment of each unique combination of suspect LP was conducted to assess the condition of the paint. The condition of the paint was documented to be either intact, top layer failure, multiple layer failure and/or substrate failure.
August 3, 2021 ■ Terracon Project No. J8217165
Responsive ■ Resourceful ■ Reliable 5
6.3 Sample Analysis
Based on results of the visual observation, Terracon performed a limited lead-based paint (LBP) measurements utilizing an X-ray fluorescence (XRF) analyzer to measure the lead content of painted components.
7.0 REGULATORY OVERVIEW – LEAD PAINT
Lead is regulated by the EPA, PADEP, and OSHA. The EPA lead use, removal, and disposal, and OSHA regulates lead exposure to workers. The EPA defines LBP as paint, varnish, stain, or other applied coating that contains lead equal to or greater than 1.0 mg/cm2, 5,000 mg/Kg, or 0.5% by dry weight (%wt) as determined by laboratory analysis. For the purpose of the OSHA lead standard, lead includes metallic lead, all inorganic lead compounds, and organic lead soaps.
A synopsis of the OSHA regulations (29 CFR 1926.62) and the applicability are as follows:
The OSHA Interim Lead Standard for Construction (29 CFR 1926.62) applies to all construction work where an employee may be occupationally exposed to lead. All work related to construction, alteration, or repair (including painting and decorating) is included. The lead-in-construction standard applies to any detectable concentration of lead in paint, as even small concentrations of lead can result in unacceptable employee exposures depending upon on the method of removal and other workplace conditions. Under this standard, construction includes, but is not limited to, the following:
n Demolition or salvage of structures where lead or materials containing lead are present n Removal or encapsulation of materials containing lead n New construction, alteration, repair, or renovation of structures, substrates, or portions containing lead, or materials containing lead n Installation of products containing lead n Lead contamination/emergency clean-up n Transportation, disposal, storage, or containment of lead or materials containing lead on the site or location at which construction activities are performed n Maintenance operations associated with construction activities described above
8.0 FINDINGS AND RECOMMENDATIONS – LEAD PAINT
All suspect LP samples analyzed had concentrations above the 1.0 mg/cm2 standard (the minimum concentration to be considered LP); therefore, the samples do qualify as lead paint.
OHSA also regulates lead in any quantifiable amount for employee exposures. This should be brought to the attention of contractors who may disturb that paint for OSHA compliance purposes.
A lead paint sample summary is included in Appendix B.
August 3, 2021 ■ Terracon Project No. J8217165
Responsive ■ Resourceful ■ Reliable 6
9.0 LIMITATIONS/GENERAL COMMENTS
In addition to limitations discussed in other sections of this report, Terracon did not perform sampling requiring demolition or destructive activities such as knocking holes in walls, dismantling of equipment or removal of protective coverings. Reasonable efforts to access suspect materials within known areas of restricted access (e.g., crawl spaces) were made; however, confined spaces or areas which may pose a health or safety risk to Terracon personnel were not sampled.
Sampling did not include suspect materials which could not be safely reached with available ladders/man-lifts. Terracon typically investigated for flooring beneath carpeting by lifting small corner sections of carpet in safely accessible areas. If tiles were seen, they have been identified in the report. If tiles were not seen at corners under the carpet, it does not imply that there are no tiles beneath the carpeted floor. Terracon sampled accessible flooring materials and did conduct destructive investigation on floors to identify multi-layered tile/underlayment systems, concealed paper, vapor barriers, or floor tiles/mastics under wood floor systems. Terracon did not conduct destructive investigation of doors in the building to determine if the doors were insulated for fire-rating purposes.
This survey was conducted in a manner consistent with the level of care and skill ordinarily exercised by members of the profession currently practicing under similar conditions in the same locale. The results, findings, conclusions and recommendations expressed in this report are based on conditions observed during our survey of the office building. The information contained in this report is relevant to the date on which this survey was performed and should not be relied upon to represent conditions at a later date.
If a future renovation or demolition project will have an impact on any of the above-referenced hazardous material items, please be aware that they will need to be addressed and planned for accordingly applicable federal, state, and local regulations.
This report has been prepared on behalf of and exclusively for use by The Johnson-McAdams Firm PA for specific application to their project as discussed. This report is not a bidding document. Contractors or consultants reviewing this report must draw their own conclusions regarding further investigation or remediation deemed necessary. Terracon does not warrant the work of regulatory agencies, laboratories or other third parties supplying information which may have been used in the preparation of this report. No warranty, express or implied is made.
APPENDIX A
Sampled Suspect ACM Materials USDA Eastern Region Research Center (ERRC)
600 East Mermaid Lane Wyndmoor, Pennsylvania
HA No. Sample Number Suspect Material Description Sample Location Lab Results
01 01-CA1-01 Black Window Caulk Roof – Exterior Window 5% Chrysotile 01 01-CA1-02 Black Window Caulk Roof – Exterior Window 5% Chrysotile 01 01-CA1-03 Black Window Caulk Roof – Exterior Window 5% Chrysotile 02 02-CA1-04 Black/Brown Window Caulk Roof – Exterior Window None Detected 02 02-CA1-05 Black/Brown Window Caulk Roof – Exterior Window None Detected 02 02-CA1-06 Black/Brown Window Caulk Roof – Exterior Window None Detected 03 03-CA1-07 Grey Window Caulk Roof – Exterior Window 5% Chrysotile 03 03-CA1-08 Grey Window Caulk Roof – Exterior Window 5% Chrysotile 03 03-CA1-09 Grey Window Caulk Roof – Exterior Window 5% Chrysotile 04 04-CA1-10 Light Grey Window Caulk Roof – Exterior Window 10% Chrysotile 04 04-CA1-11 Light Grey Window Caulk Roof – Exterior Window 10% Chrysotile 04 04-CA1-12 Light Grey Window Caulk Roof – Exterior Window 10% Chrysotile 05 05-SC1-13 Window Glazing Attic Area – Interior Window None Detected 05 05-SC1-14 Window Glazing Attic Area – Interior Window 3% Chrysotile 05 05-SC1-15 Window Glazing Attic Area – Interior Window 4% Chrysotile
APPENDIX B
SAMPLED SUSPECT LEAD PAINT MATERIALS
USDA Eastern Region Research Center (ERRC)
600 East Mermaid Lane Wyndmoor, Pennsylvania
Test
ID
Color Substrate Component Location Condition
(Intact, Fair, or Poor)
Test Result (mg/cm2)
1 Grey Metal Window Exterior of Window (Roof) Fair 10.00 +/- 0.10 2 Grey Metal Window Exterior of Window (Roof) Fair 8.52 +/- 0.20 3 Grey Metal Window Exterior of Window (Roof) Fair 8.29 +/- 0.26 4 Grey Metal Window Exterior of Window (Roof) Fair 7.63 +/- 0.17 5 Grey Metal Window Exterior of Window (Roof) Fair 9.99 +/- 0.33 6 Grey Metal Window Exterior of Window (Roof) Fair 6.73 +/- 0.24 7 Grey Metal Window Exterior of Window (Roof) Fair 7.61 +/- 0.25 8 Grey Metal Window Exterior of Window (Roof) Fair 11.09 +/- 0.34 9 Grey Metal Window Exterior of Window (Roof) Fair 10.91 +/- 0.31
APPENDIX C
ASBESTOS LABORATORY ANALYTICAL DATA
EMSL Analytical, Inc.
5221 Militia Hill Road Plymouth Meeting, PA 19462
Tel/Fax: (610) 828-3102 / (610) 828-3122 http://www.EMSL.com / plymouthmeetinglab@emsl.com
182102366EMSL Order:
Customer ID: TRHQ42B
Customer PO: J8217165
Project ID:
Attention: Phone:Amanda Ege (267) 512-7050
Fax:Terracon Consultants, Inc.
Received Date:47 Runway Road 06/28/2021 11:00 PM
Analysis Date:Suite I 07/05/2021
Collected Date:Levittown, PA 19057
Project: J8217165
Test Report: Asbestos Analysis of Bulk Materials via EPA 600/R-93/116 Method using Polarized
Light Microscopy
Sample Description Appearance % Fibrous % Non-Fibrous
Non-Asbestos Asbestos
% Type
01-CA1-01
182102366-0001
5% ChrysotileNon-fibrous (Other)95%Gray/Black
Non-Fibrous
Homogeneous
Exterior Windows -
Roof - Black Window
Caulk
HA: 01
01-CA1-02
182102366-0002
5% ChrysotileNon-fibrous (Other)95%Gray/Black
Non-Fibrous
Homogeneous
Exterior Windows -
Roof - Black Window
Caulk
HA: 01
01-CA1-03
182102366-0003
5% ChrysotileNon-fibrous (Other)95%Gray/Black
Non-Fibrous
Homogeneous
Exterior Windows -
Roof - Black Window
Caulk
HA: 01
02-CA1-04
182102366-0004
None DetectedNon-fibrous (Other)100%Brown/Black
Non-Fibrous
Homogeneous
Exterior Windows -
Roof - Black/Beam
Window Caulk
HA: 02
02-CA1-05
182102366-0005
None DetectedNon-fibrous (Other)100%Brown/Black
Non-Fibrous
Homogeneous
Exterior Windows -
Roof - Black/Beam
Window Caulk
HA: 02
02-CA1-06
182102366-0006
None DetectedNon-fibrous (Other)100%Brown/Black
Non-Fibrous
Homogeneous
Exterior Windows -
Roof - Black/Beam
Window Caulk
HA: 02
03-CA1-07
182102366-0007
5% ChrysotileNon-fibrous (Other)95%Gray
Non-Fibrous
Homogeneous
Exterior Windows -
Roof - Gray Window
Caulk
HA: 03
03-CA1-08
182102366-0008
5% ChrysotileNon-fibrous (Other)95%Gray
Non-Fibrous
Homogeneous
Exterior Windows -
Roof - Gray Window
Caulk
HA: 03
03-CA1-09
182102366-0009
5% ChrysotileNon-fibrous (Other)95%Gray
Non-Fibrous
Homogeneous
Exterior Windows -
Roof - Gray Window
Caulk
HA: 03
04-CA1-10
182102366-0010
10% ChrysotileNon-fibrous (Other)90%Gray
Non-Fibrous
Homogeneous
Exterior Windows -
Roof - Light Gray
Window Caulk
04-CA1-11
182102366-0011
10% ChrysotileNon-fibrous (Other)90%Brown/Gray
Non-Fibrous
Homogeneous
Exterior Windows -
Roof - Light Gray
Window Caulk
HA: 04
04-CA1-12
182102366-0012
10% ChrysotileNon-fibrous (Other)90%Gray
Non-Fibrous
Homogeneous
Exterior Windows -
Roof - Light Gray
Window Caulk
HA: 04
Initial report from: 07/05/2021 13:50:08
Page 1 of 2ASB_PLM_0008_0001 - 1.78 Printed: 7/5/2021 1:50 PM
EMSL Analytical, Inc.
5221 Militia Hill Road Plymouth Meeting, PA 19462
Tel/Fax: (610) 828-3102 / (610) 828-3122 http://www.EMSL.com / plymouthmeetinglab@emsl.com
182102366EMSL Order:
Customer ID: TRHQ42B
Customer PO: J8217165
Project ID:
Test Report: Asbestos Analysis of Bulk Materials via EPA 600/R-93/116 Method using Polarized
Light Microscopy
Sample Description Appearance % Fibrous % Non-Fibrous
Non-Asbestos Asbestos
% Type
05-SC1-13
182102366-0013
None DetectedNon-fibrous (Other)100%Gray
Non-Fibrous
Homogeneous
Attic Windows -
Window Glazing
HA: 05
05-SC1-14
182102366-0014
3% ChrysotileNon-fibrous (Other)97%Tan
Non-Fibrous
Homogeneous
Attic Windows -
Window Glazing
HA: 05
05-SC1-15
182102366-0015
4% ChrysotileNon-fibrous (Other)96%Gray
Non-Fibrous
Homogeneous
Attic Windows -
Window Glazing
HA: 05
Analyst(s)
Daniel Denora (15) Kevin Ream, Laboratory Manager or Other Approved Signatory
EMSL maintains liability limited to cost of analysis . Interpretation and use of test results are the responsibility of the client. This report relates only to the samples reported above, and may not be reproduced, except in full, without written approval by EMSL. EMSL bears no responsibility for sample collection activities or analytical method limitations . The report reflects the samples as received.
Results are generated from the field sampling data (sampling volumes and areas, locations, etc.) provided by the client on the Chain of Custody. Samples are within quality control criteria and met method specifications unless otherwise noted. The above analyses were performed in general compliance with Appendix E to Subpart E of 40 CFR (previously EPA 600/M4-82-020 “Interim Method”) but augmented with procedures outlined in the 1993 (”final”) version of the method. This report must not be used by the client to claim product certification, approval, or endorsement by NVLAP, NIST or any agency of the federal government. Non- friable organically bound materials present a problem matrix and therefore EMSL recommends gravimetric reduction prior to analysis . Unless requested by the client, building materials manufactured with multiple layers (i.e. linoleum, wallboard, etc.) are reported as a single sample. Estimation of uncertainty is available on request.
Samples analyzed by EMSL Analytical, Inc. Plymouth Meeting, PA NVLAP Lab Code 200699-0, Philadelphia ALL-292, VA 3333000315, AIHA-LAP, LLC IHLAP #178659
Initial report from: 07/05/2021 13:50:08
Page 2 of 2ASB_PLM_0008_0001 - 1.78 Printed: 7/5/2021 1:50 PM
OrderID: 182102366
OrderID: 182102366
APPENDIX D
LICENSES AND CERTIFICATIONS
Certificate of Training
CRITERION LABORATORIES, INC.
400 Street Road Bensalem, PA 19020
(215) 244-1300 - Phone
(215) 244-4349 - Fax www.criterionlabs.com
Course is conducted in English
HEREBY CERTIFIES THAT
Amanda Ege
HAS SUCCESSFULLY COMPLETED A 4 HOUR TELECONFERENCE COURSE ENTITLED
Asbestos Building Inspector Refresher
INCLUDING CLASSROOM INSTRUCTION
Number 751934 on this 5th day of January 2021
James A. Weltz, CIH, President
DIRECTOR:
Expiration Date:
01/05/2022
Approved for AHERA Accreditation Under TSCA Title II
Rev. 20170501
Un ite d St at es
D ep ar tm en to fC om m er ce N at io na lI ns tit ut e of St an da rd s an d
Te ch no lo gy
Ce rt ifi ca te of
A cc re di ta tio n to
IS
O
/IE
C
5:
is ac cr ed ite d by th e N at io na lV ol un ta ry
La bo ra to ry Ac cr ed ita tio n Pr og ra m fo rs pe ci fic se rv ic es lis te d on th e Sc op e of Ac cr ed ita tio n, fo r:
E ffe ct iv e D at es
Fo rt he N at io na lV ol un ta ry
La bo ra to ry A cc re di ta tio n
P ro gr am
Th is la bo ra to ry is ac cr ed ite d in ac co rd an ce w ith th e re co gn iz ed
In te rn at io na lS ta nd ar d
IS
O
/IE
C
5:
Th is ac cr ed ita tio n de m on st ra te s te ch ni ca lc om pe te nc e fo ra de fin ed sc op e an d th e op er at io n of a la bo ra to ry qu al ity m an ag em en ts ys te m
(re fe rt o jo in tI
SO
-IL
AC
-IA
F
C om m un iq ue da te d Ja nu ar y
APPENDIX E
PHOTOS
USDA ERRC – Limited Asbestos and Lead Paint Survey ■ Wyndmoor, PA Date Pictures Taken: June 25, 2021 ■ Terracon Project No. J8217165
Responsive ■ Resourceful ■ Reliable
Photo 1 View of black window caulk (HA# 01) Photo 2 View of light grey window caulk (HA# 04)
Photo 3 View of grey window caulk (HA# 03) Photo 4 View of window glazing (HA# 05)
Photo 5 View of grey window paint Photo 6 View of grey window paint
| 2021-08-03T08:57:13-0400 | |
| Ege, Amanda M |
| 2021-08-03T10:57:11-0400 | |
| Candela, Chris J |