11-FDOT Utility Permit.pdf
PDF 30 MB Posted
- Attached to
- 26B-083 Golden Holiday WWTP and WTP Decommissioning and Lift Station and Force Main Installation
- Solicitation number
- 26-083
- Issued by
- Marion County, Florida
About this file
This is a Florida Department of Transportation (FDOT) Utility Permit (Permit No. 2025-H-595-00242) issued to Marion County Utilities for installation of utility infrastructure within the state right-of-way on US Highway 27 (SR 500) in Marion County, Florida. The primary project involves installation of a buried 3-inch HDPE sewer forcemain using horizontal directional drilling (HDD) beneath the existing sidewalk and utilities on the north side of the roadway within the FDOT right-of-way, extending from NW 32nd Avenue to Old Blitchton Road. Marion County Utilities will construct the project in conjunction with a new pump station and proposed sewer forcemain, with ownership, operation, and maintenance responsibilities to be transferred to the City of Ocala upon completion. The permit was approved on January 8, 2026, with an anticipated start date of April 1, 2026, requiring completion within 18 calendar days. Traffic control must comply with FDOT 600, 611, 660, and 604 series standards, and work is restricted from 3:00 p.m. to 6:00 p.m. with no eastbound or westbound lane closures permitted during those hours. Open trenches and bore pits must be restored by end of each work shift, and coordination with the City of Ocala is required minimum two business days prior to work within 500 feet of signalized intersections.
The permit incorporates extensive special instructions and design standards addressing erosion and sedimentation control, utility accommodation, traffic management, and restoration requirements. Existing utilities identified within the project limits include facilities owned by Lumen (CenturyLink), TECO Peoples Gas, City of Ocala (Water and Electric), and Duke Energy. The project design, prepared by Ardurra Group, Inc., includes detailed permit plans with cross-sections, plan and profile sheets, and maintenance of traffic details. An FDOT representative presence is not required on the worksite prior to commencement, and the contractor must call Sunshine 811 a minimum of two business days before beginning work. As-built plans, bore logs, and the Engineer's As-Built Certification must be submitted to One Stop Permitting within 15 calendar days of project completion. The MOT Technician contact information and specific FDOT Inspector coordination details are provided, with Raul Cepeda designated as the FDOT representative for notifications at (352) 672-7299.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
Rule 14-46.001 F.A.C.
FLORIDA DEPARTMENT OF TRANSPORTATION December 14, 2016
UTILITY PERMIT
PERMIT NO:__________________________________
STATE ROAD INFORMATION
County: Section: State Road No: Beginning Mile Post: Ending Mile Post:
APPLICANT INFORMATION
The Utility Agency Owner (UAO) shall be identified in this Applicant Information Box. When the UAO is a City or County and desires to have the Utility Builder make a joint permit applicant, as prescribed in Section 2.1(4) of the 2017 Utility Accommodation Manual (UAM), the Utility Builder shall also be identified in this Applicant Information Box. A Utility Builder alone cannot apply for a utility permit without the City or County adding them as a joint applicant.
Utility Agency/Owner (UAO) Utility Builder (only applicable when the UAO is a City or County) Name: _____________________________________ Name: ______________________________________
Contact Person: _____________________________________ Contact Person: ______________________________________ Address: _____________________________________ Address: ______________________________________
City: _____________________________________ City: ______________________________________ State: _____ State: _____ Zip: _________ Zip: _________
Telephone: _____________________________________ Telephone: ______________________________________ Email: ____________________________________ Email: ______________________________________
WORK DESCRIPTION
The Applicant(s) requests permission from the Florida Department of Transportation (FDOT) to construct, operate, and maintain the utilities as described below and as depicted in the incorporated documentation.
Utility Work No: ___________________________
Additional sheets are attached and are incorporated into this permit Yes No For FDEP certification, the FDOT agency report is attached in accordance with UAM Section 2.4.1 (13) Yes No
TRAFFIC CONTROL (TCP)
The TCP will comply with the following 600 series index(es) ________________________________________________________________________ A TCP has been attached and incorporated into this permit application in compliance with UAM Section 2.4.2.
MOT Technician’s contact information (may be supplied at the two (2) business day notification to FDOT):
Name: ________________________________ Telephone ________________________ Email: _______________________________
COMMENCEMENT OF WORK
The UAO and/or Utility Builder shall commence actual construction in good faith within sixty (60) calendar days after approval of the permit application. If the beginning date is more than sixty (60) calendar days from the date of approval, the UAO and/or Utility Builder must review the permit with the FDOT Approving Engineer listed to make sure no changes have occurred to the transportation facility that would affect the permit’s continued approval. The UAO and/or Utility Builder shall make good faith efforts to expedite the work and complete the work within the calendar days indicated.
Anticipated Start Date: ___________________ Calendar days needed to completed: ________
Marion
(352) 307-4625 ext. ______
Florida
SR 500
Marion County Utilities
4/1/2026
18.127
11800 S US HWY 441
600, 611, 660, 604
34420
Installation of buried 3" HDPE sewer forcemain by means of horizontal directional drill. Installation will be below existing sidewalk and other existing utilities on the north side of roadway within US-27 (SR 500) right of way from NW 32nd Avenue to Old Blitchton Road. Bore contractor will need to verify exact position of utilities prior to bore installation.
Marion County Utilities will be constructing this project with a new pump station and the proposed sewer forcemain ... (see work description cont. page)
2025-H-595-00242
36070000
Marion County Utilities
Belleview
Utilities@marionfl.org
18.656
Approved 2025-H-595-00242
Nicole Aiton 1/8/2026
Florida Department of Transportation
UTILITY PERMIT
December 14, 2016
PERMIT NO:_________________________________
APPLICANT SIGNATURE
By the below signature(s) the UAO and/or Utility Builder agree(s) to construct, operate, and maintain the work as noted in the above Work Description, shown in plans and incorporated documents, in compliance with the UAM, all instructions noted in the FDOT Special Instructions Box, and special instructions incorporated into this permit. The UAO and/or Utility Builder declares, the location of all existing utilities that it owns or has an interest in, both aerial and underground, are accurately shown on the plans of the work areas. In accordance with UAM Section 2.8, the UAO and/or Utility Builder further declares that a letter of notification was delivered to the owners of other facilities within the work areas and that those listed below are the only facility owners known to be involved or potentially impacted by the proposed work.
Date Notified: Name of other facility owners (attach additional sheets if necessary).
Utility Agency/Owner Utility Builder (when applicable)
Signature: ____________________________ Date: ________________ Signature:___________________________ Date: _______________ Name (printed): _____________________________________________ Name (printed): __________________________________________ Title: ______________________________________________________ Title: ___________________________________________________
FDOT PROJECT INFORMATION
Pursuant to UAM Section 2.1(10), the utility work is within FDOT projects listed below and must have a Utility Work Schedule for each project approved prior to commencement of work within the FDOT project limits:
FDOT SPECIAL INSTRUCTIONS
In accordance with UAM Section 2.7, FDOT incorporates the below and attached special instructions into this permit.
Additional FDOT Special Instructions are attached and incorporated into this permit. Yes No
PERMIT APPROVAL
By signature below, FDOT gives permission to the UAO and /or Utility Builder to construct, operate, and maintain the utilities indicated in this Utility Permit in compliance with the UAM, all incorporated documents, and special instructions. Any changes to the approved work must be approved by the FDOT’s Approving Engineer and attached and incorporated into this permit in accordance with UAM Section 2.11.
Approving Engineer: _____________________________________________ Date: _______________ Name: _____________________________________________
Title:______________________________________________
Notification of Utility Work to be provided to: Telephone _____________________ or Email: _____________________________
An FDOT Representative is required to be present on the worksite prior to commencement of work. Yes No Rep. Name: _____________________________ Telephone _____________________ Email: _____________________________
1/8/2026
No EB or WB lane closures 3:00pm-6:00pm No open trenches or bore pits to be left open overnight. Open trenches and bore pits must be restored by the end of each day’s work shift. When working within 500’ of a signalized intersection or other traffic control devices contact City of Ocala, Nick Blizzard, at 352-351-6707 a minimum of two (2) business days prior to work.
Installation of buried 3" HDPE sewer forcemain by means of horizontal directional drill ... (see special instructions cont. page)
11/6/2025
(352) 620-3000 ext. ______ D5-595Permits@dot.state.fl.us
Nicole Aiton
Nicole Aiton (digital signature) raul.cepeda@oasislandscapeservices.com
JOSH KRAMER (digital signature)
City of Ocala - Water11/4/2025 Centurylink (Lumen)11/4/2025 TECO Peoples Gas11/4/2025 City of Ocala - Electric11/4/2025
JOSH KRAMER
3526727299Raul Cepeda
OPERATIONS PROGRAM ENGINEER
2025-H-595-00242
There are NO FDOT constructions (proposed or underway).
This work is NOT related to an approved Utility Work Schedule.
Approved 2025-H-595-00242
Florida Department of Transportation
UTILITY PERMIT
December 14, 2016
PERMIT NO:_________________________________
CERTIFICATION
I, the undersigned UAO and/or Utility Builder, hereby CERTIFY that the utilities were constructed and inspected in compliance with the UAM all incorporated documents, and special instructions. Pursuant to UAM Section 2.11, all changes have been approved by the FDOT’s Approving Engineer and incorporated into this permit along with all other material certifications, test results, bore logs, approved plans changes, as-built plans or other required documentation.
I also CERTIFY that work began on ________________ and was completed on ________________ and that the area was left in as good or better condition than when the work began.
Utility Agency/Owner Utility Builder (when applicable)
Signature: ____________________________ Date _________________ Signature:___________________________ Date ________________ Name (printed): _____________________________________________ Name (printed): ____________________________________________ Title: ______________________________________________________ Title: ____________________________________________________
FINAL INSPECTION OF WORK
The work was inspected and found to be in non-compliance as noted below:
All issues of non-compliance listed above have been brought into compliance and/or FDOT has no outstanding issues that need to be addressed by the UAO and/or Utility Builder. However, this final inspection does not release the UAO and/or Utility Builder of their continuing responsibilities pursuant to Rule 14-46.001, the UAM, all incorporated documents, and special instructions.
FDOT Inspector: _____________________________________________ Date: _______________ Name: _____________________________________________
Title: ______________________________________________
2025-H-595-00242
Approved 2025-H-595-00242
PERMIT NO.:
The complete Work Description could not fit in the space allotted on Page 1 of the Utility Permit so it is displayed below.
Work Description work description continuation page
2025-H-595-00242
Installation of buried 3" HDPE sewer forcemain by means of horizontal directional drill. Installation will be below existing sidewalk and other existing utilities on the north side of roadway within US-27 (SR 500) right of way from NW 32nd Avenue to Old Blitchton Road. Bore contractor will need to verify exact position of utilities prior to bore installation.
Marion County Utilities will be constructing this project with a new pump station and the proposed sewer forcemain within FDOT right of way. After completion, MCU will transfer ownership, operation, and maintenance responsibilities to City of Ocala for the proposed forcemain within FDOT right of way.
Approved 2025-H-595-00242
PERMIT NO.:
The complete special instructions could not fit in the space allotted on Page 2 of the Utility Permit so they are displayed below.
Special FDOT Instructions special instructions continuation page
No EB or WB lane closures 3:00pm-6:00pm No open trenches or bore pits to be left open overnight. Open trenches and bore pits must be restored by the end of each day’s work shift. When working within 500’ of a signalized intersection or other traffic control devices contact City of Ocala, Nick Blizzard, at 352-351-6707 a minimum of two (2) business days prior to work.
Installation of buried 3" HDPE sewer forcemain by means of horizontal directional drill MCU will transfer ownership, operation, and maintenance responsibilities to City of Ocala for the proposed forcemain
2025-H-595-00242
Approved 2025-H-595-00242
Station: 52+14
0+000+200+400+600+801+00
Station: 55+69
0+000+200+400+600+801+00 Station: 56+25
0+000+200+400+600+801+00
Station: 52+79
-1+00 -0+80 -0+60 -0+40 -0+20 0+00
N O
D
A
TE
R E
V
IS
IO
N
B Y
DATE:
JOB NO:
10/28/2025
208.69
MARION COUNTY UTILITIES
11800 SE US HWY 441
BELLEVIEW, FL 34420
352-307-6000
A
B
C
D
E
F
G
H
2 3 4 5 6 7 8 9 10 11 12
1 2 3 4 5 6 7 8 9 10 11 12
SE
CT
IO
N
1&
, T
W P.
6S
,1 5S
, R N
G.
3E , D
AT
U
M : F
L8 3.
W F-
N
AV
D.
T:\208 Marion County\69_Golden Holiday Off-Site Sewer\dwg\_PE\+xrefs\FDOT Cross Section.dwg
G O
LD
E
N H
O
LI
D A
Y W
W
TF
D E
C O
M M
IS
S
IO
N
IN
G
U S
-2
(S R
U
TI
LI
TY
C
R O
S S
S E
C
TI
O N
S
90% PLANS
10/28/2025
Ardurra Group, Inc.
925 S.E. 17th Street, Suite A
Ocala, Florida 34471 Phone: (352) 861-7799 www.Ardurra.com License #26531
EXHIBIT A
NOTE:
1. SEE SHEET C3.02 FOR PLAN VIEW
Approved 2025-H-595-00242
US-27
Rural King
N W
7t h A ve
I-7
NW Old Blitchton Rd
N W
5t h A ve
EXISTING GOLDEN
HOLIDAY WWTF
PROJECT
LOCATION
925 S.E. 17th Street, Suite A Ocala, Florida 34471
Phone: (352) 861-7799 www.Ardurra.com
REVISED PERMIT PLANS
DATE: 01/05/2026
THIS ITEM HAS BEEN DIGITALLY SIGNED
AND SEALED BY MITCHELL R. CHAUNCEY,
P.E. ON THE DATE ADJACENT TO THE
SEAL. THE SIGNATURE MUST BE VERIFIED
ON ANY ELECTRONIC COPIES.
Approved 2025-H-595-00242
STANDARD ABBREVIATIONS:
ENGINEERING LEGEND:
N O
D
A
TE
R E
V
IS
IO
N
B Y
DATE:
JOB NO:
12/8/2025
208.69
MARION COUNTY UTILITIES
11800 SE US HWY 441
BELLEVIEW, FL 34420
352-307-6000
A
B
C
D
E
F
G
H
2 3 4 5 6 7 8 9 10 11 12
1 2 3 4 5 6 7 8 9 10 11 12
SE
CT
IO
N
1&
, T
W P.
6S
,1 5S
, R N
G.
3E , D
AT
U
M : F
L8 3.
W F-
N
AV
D.
T:\208 Marion County\69_Golden Holiday Off-Site Sewer\dwg\_PE\02 ABB-LEGEND.dwg
G O
LD
E
N H
O
LI
D A
Y W
W
TF
D E
C O
M M
IS
S
IO
N
IN
G
A B
B R
E V
IA
TI
O N
S A
N D
L E
G E
N D
PERMIT PLANS
12/8/2025
Ardurra Group, Inc.
925 S.E. 17th Street, Suite A
Ocala, Florida 34471 Phone: (352) 861-7799 www.Ardurra.com License #26531
18OFC1.01
S
SURVEY BASEMAP LEGEND AND ABBREVIATIONS:
Approved 2025-H-595-00242
Nicole Aiton 1/8/2026
MChauncey Text Box THIS ITEM HAS BEEN DIGITALLY SIGNED AND SEALED BY MITCHELL R. CHAUNCEY, P.E. ON THE DATE ADJACENT TO THE SEAL. THE SIGNATURE MUST BE VERIFIED ON ANY ELECTRONIC COPIES.
N O
D
A
TE
R E
V
IS
IO
N
B Y
PERMIT PLANS
12/8/2025
DATE:
JOB NO:
12/8/2025
208.69
MARION COUNTY UTILITIES
11800 SE US HWY 441
BELLEVIEW, FL 34420
352-307-6000
A
B
C
D
E
F
G
H
2 3 4 5 6 7 8 9 10 11 12
1 2 3 4 5 6 7 8 9 10 11 12
SE
CT
IO
N
1&
, T
W P.
S, R
N G.
E, D
AT
U
M : F
L8 3.
W F-
N
AV
D.
EROSION AND SEDIMENTATION CONTROL NOTES:
1. THE INSTALLATION OF TEMPORARY EROSION CONTROL BARRIERS SHALL BE COORDINATED WITH THE
CONSTRUCTION OF THE PERMANENT EROSION CONTROL FEATURES TO THE EXTENT NECESSARY TO ASSURE ECONOMICAL, EFFECTIVE AND CONTINUOUS CONTROL OF EROSION AND WATER POLLUTION THROUGHOUT THE LIFE
OF THE CONSTRUCTION PHASE.
2. THE TYPE OF EROSION CONTROL BARRIERS USED SHALL BE GOVERNED BY THE NATURE OF THE CONSTRUCTION OPERATION AND SOIL TYPE THAT WILL BE EXPOSED. SILTY AND CLAYEY MATERIAL USUALLY REQUIRE SOLID SEDIMENT BARRIERS TO PREVENT TURBID WATER DISCHARGE, WHILE SANDY MATERIAL MAY NEED ONLY SILT SCREENS OR SYNTHETIC BALES TO PREVENT EROSION. FLOATING TURBIDITY CURTAINS SHOULD BE USED IN OPEN WATER SITUATIONS. DIVERSION DITCHES OR SWALES MAY BE REQUIRED TO PREVENT TURBID STORMWATER RUNOFF FROM BEING DISCHARGED TO WETLANDS OR OTHER WATER BODIES. IT MAY BE NECESSARY TO EMPLOY A COMBINATION OF BARRIERS, DITCHES, AND OTHER EROSION/TURBIDITY CONTROL MEASURES IF CONDITIONS
WARRANT.
3. WHERE PUMPS ARE TO BE USED TO REMOVE TURBID WATERS FROM THE CONSTRUCTION AREA, THE WATER SHALL BE TREATED TO REDUCE TURBIDITY TO STATE WATER QUALITY STANDARDS PRIOR TO DISCHARGE TO THE WETLANDS. TREATMENT METHODS INCLUDE, FOR EXAMPLE, TURBID WATER BEING PUMPED INTO GRASSED SWALES OR APPROPRIATE VEGETATED AREAS (OTHER THAN UPLAND PRESERVATION AREAS AND WETLAND BUFFERS), SEDIMENT BASINS, OR CONFINED BY AN APPROPRIATE ENCLOSURE SUCH AS TURBIDITY BARRIERS, AND
KEPT CONFINED UNTIL ITS TURBIDITY LEVEL MEETS STATE WATER QUALITY STANDARDS.
4. THE CONTRACTOR SHALL PROVIDE ROUTINE MAINTENANCE OF PERMANENT AND TEMPORARY EROSION CONTROL FEATURES UNTIL THE PROJECT IS COMPLETE AND ALL BARED SOIL STABILIZED. SILTATION ACCUMULATIONS GREATER THAN THE LESSER OF 12 INCHES OR ONE-HALF THE DEPTH OF THE SILTATION CONTROL BARRIER SHALL
BE IMMEDIATELY REMOVED AND PLACED IN UPLAND AREAS.
5. ALL SOIL EROSION AND SEDIMENT CONTROL PRACTICES SHALL BE INSTALLED PRIOR TO ANY MAJOR SOIL DISTURBANCE OR IN THEIR PROPER SEQUENCE, AND MAINTAINED UNTIL PERMANENT PROTECTION IS
ESTABLISHED.
6. CONSTRUCTION OPERATIONS SHALL BE CARRIED OUT IN SUCH A MANNER THAT EROSION AND AIR AND WATER POLLUTION WILL BE MINIMIZED. STATE AND LOCAL LAWS SHALL BE COMPLIED WITH AT ALL TIMES.
7. TO MINIMIZE SOIL EROSION, PROPOSED LAND ALTERATION ACTIVITIES SHALL NOT UNNECESSARILY REMOVE EXISTING VEGETATION AND ALTER EXISTING TOPOGRAPHY. ADEQUATE PROTECTION MEASURES (I.E. SYNTHETIC BALES, BAFFLES, SODDING AND SANDBAGGING) SHALL BE PROVIDED, AS NECESSARY, TO MINIMIZE EROSION AND DOWNSTREAM SEDIMENTATION CAUSED BY SURFACE WATER RUN-OFF ON EXPOSED LAND SURFACES.
8. ALL NEW EROSION AND SILT CONTROL METHODS AND LOCATIONS INDICATED ON THIS PLAN SET ARE FOR START-UP AND GENERAL REFERENCE ONLY AND SHALL BE ADJUSTED, AS REQUIRED, TO SUIT THE PROCESS OF THE
CONSTRUCTION.
9. ANY AREAS SUBJECT TO EROSION MUST BE ADEQUATELY STABILIZED WITH VEGETATIVE MATERIAL THAT WILL, WITHIN A REASONABLE TIME FRAME, DETER SOIL DISTURBANCE. SODDING, PLUGGING, SPRIGGING. OR SEEDING IS ACCEPTABLE FOR STABILIZATION; HOWEVER, SODDING MAY BE REQUIRED IN AREAS OF EROSION-PRONE SOILS OR WHERE SLOPES ARE GREATER THAN 5:1. VEGETATION OTHER THAN GRASS IS ACCEPTABLE UNLESS OTHERWISE
SPECIFIED.
10. CONTRACTOR TO COMPLY WITH ALL REGULATIONS AS SET FORTH BY THE FDEP NPDES STORMWATER REGULATORY
PROGRAM.
11. THE CONTRACTOR SHALL BE RESPONSIBLE TO MAKE A REVIEW OF THE SITE TO DETERMINE EXISTING CONDITIONS AND ANYTHING NOT COVERED IN THE CONTRACT DOCUMENTS SHALL BE BROUGHT TO THE ATTENTION OF THE OWNER AND SHALL NOT CONSTITUTE AN EXTRA, UNLESS APPROVED IN WRITING BY THE OWNER.
SEWER AND WATER SYSTEM NOTES:
1. ALL ON-SITE PVC FORCEMAINS 2-3 INCHES SHALL BE CLASS 1120 OR 1220 (SDR 21) AND MEET REQUIREMENTS OF
ASTM D-2241. PE PIPE 2" OR SMALLER SHALL MEET THE REQUIREMENTS OF ASTM D-1248. HDPE 4" OR SMALLER
SHALL MEET THE REQUIREMENTS OF ASTM F-714.
2. VALVES AND FITTINGS SHALL BE IN ACCORDANCE WITH AWWA C110 OR AWWA C153.
3. ALL FORCEMAINS TO BE CONSTRUCTED WITH MINIMUM 3 FEET OF COVER.
4. APPROXIMATE FORCEMAINS DISTANCES SHOWN ARE BETWEEN CENTERS OF MAIN FITTINGS. THE CONTRACTOR
SHALL PROVIDE ALL FITTINGS REQUIRED FOR A COMPLETE FORCEMAIN SYSTEM.
5. NO DEBRIS SHALL BE ALLOWED TO ENTER THE EXISTING SANITARY SYSTEM.
6. SANITARY SEWERS, FORCEMAINS, AND STORM SEWERS SHOULD ALWAYS CROSS UNDER WATER MAINS. SANITARY SEWERS, FORCEMAINS AND STORM SEWERS CROSSING WATER MAINS SHALL BE LAID TO PROVIDE A MINIMUM VERTICAL DISTANCE OF 18-INCHES BETWEEN THE INVERT OF THE UPPER PIPE AND THE CROWN OF THE LOWER
PIPE WHENEVER POSSIBLE.
7. WHERE SANITARY SEWERS, FORCEMAINS AND STORM SEWERS MUST CROSS A WATER MAIN WITH LESS THAN 18-INCHES VERTICAL DISTANCE, BOTH THE SEWER AND THE WATER MAIN SHALL BE CONSTRUCTED OF DUCTILE IRON PIPE (DIP) AT THE CROSSING. (DIP IS NOT REQUIRED FOR STORM SEWERS IF IT IS NOT AVAILABLE IN THE SIZE PROPOSED.) SUFFICIENT LENGTHS OF DIP MUST BE USED TO PROVIDE A MINIMUM SEPARATION OF 10 FEET BETWEEN ANY TWO JOINTS. ALL JOINTS ON THE WATER MAIN WITHIN 20 FEET OF THE CROSSING MUST BE LEAK FREE, AND MECHANICALLY RESTRAINED. A MINIMUM VERTICAL CLEARANCE OF 6-INCHES MUST BE MAINTAINED AT
THE CROSSING.
8. WHERE THERE IS NO ALTERNATIVE TO SEWER PIPES CROSSING OVER THE WATER MAIN, THE CRITERIA FOR MINIMUM SEPARATION OF 18-INCHES BETWEEN LINES AND 10 FEET BETWEEN JOINTS SHALL BE REQUIRED.
9. ALL CROSSINGS SHALL BE ARRANGED SO THAT THE SEWER PIPE JOINTS AND THE WATER MAIN PIPE JOINTS ARE EQUIDISTANT FROM THE POINT OF CROSSING (PIPES CENTERED ON THE CROSSING). WHERE A NEW PIPE CONFLICTS WITH AN EXISTING PIPE, THE NEW PIPE SHALL BE CONSTRUCTED OF DIP AND THE CROSSING SHALL BE
ARRANGED TO MEET THE REQUIREMENTS ABOVE.
10. ALL NON-METALLIC PIPE WILL BE INSTALLED WITH (2) 10 GAUGE COPPER TRACER WIRES.
11. FHA EL= REFERENCE FLANGE ELEVATION (NAVD1988)
12. THE CONTRACTOR SHALL BE RESPONSIBLE FOR SUPPLYING RECORD/AS-BUILT DRAWING INFORMATION INCLUDING, BUT NOT LIMITED TO, FINISHED GRADE ELEVATIONS, TIES TO WATER LINES, VALVES, BENDS, SERVICE CONNECTIONS, ELEVATIONS OF PIPES WHERE DEPTH OF COVER VARIES FROM DESIGN, LOCATIONS OF SAMPLE POINTS FOR WATER COMPLIANCE TESTING, TIES TO SANITARY SEWER LINES, MANHOLE RIM AND INVERT ELEVATIONS, CLEANOUTS AND SERVICE CONNECTIONS, TIES TO STORM SEWER LINES, STRUCTURE TOP AND INVERT ELEVATIONS, PLUS LOCATIONS, DIMENSIONS, AND ELEVATIONS OF ALL OTHER CONSTRUCTION COMPONENTS WHICH VARY FROM THE DESIGN. RECORD/AS-BUILT INFORMATION SHALL BE RECORDED ON A COPY
OF THE DESIGN PLANS AS FOLLOWS:
- DRAW AN OVAL AROUND FEATURES OR INFORMATION THAT HAVE NOT DEVIATED FROM THE ORIGINAL DESIGN
PLANS. OVALS ARE TO BE DRAWN IN GREEN.
- STRIKE THROUGH PHYSICAL FEATURES OR INFORMATION THAT HAVE DEVIATED FROM THE ORIGINAL DESIGN
PLANS. STRIKE THROUGHS ARE TO BE DRAWN IN RED.
- DRAW THE NEW LOCATION IN RED OF FEATURES THAT DEVIATED FROM THE ORIGINAL. INCLUDE ACCURATE
DIMENSIONS TAKEN FROM FIELD MEASUREMENTS OF THE DEVIATION.
- RECORD CHANGES IN RED OF INFORMATION FOR COMPONENTS SUCH AS PIPE TYPES, VALVE TYPES, PIPE SIZES, ETC.
- ANY AND ALL DEVIATION THAT CANNOT BE SHOWN USING THE ABOVE METHODS OR THAT NEED FURTHER
EXPLANATION ARE TO BE DESCRIBED IN WORDS ON THE AS-BUILT DRAWINGS.
- THE COMPLETED AS-BUILTS ARE TO BE SIGNED AND DATED BY THE CONTRACTOR WITH THE FOLLOWING
WRITTEN STATEMENT: "I, (NAME OF PERSON CERTIFYING AS-BUILTS) CERTIFY THAT THE INFORMATION
SHOWN ON THESE AS-BUILTS IS CORRECT AND /OR ACCURATE".
15. BEDDING AND TRENCHING SHALL FOLLOW DETAIL UT103 ON SHEET C7.02 IN ALL LOCATIONS EXCEPT WHERE UNSUITABLE SOILS MAY BE ENCOUNTERED. SHOULD UNSUITABLE SOIL CONDITIONS BE ENCOUNTERED DURING TRENCHING, DETAIL UT 102 SHALL BE USED. REFER TO GEOTECHNICAL REPORT FOR EXISTING SOIL TESTING
COMPLETED.
PAVING, GRADING, AND DRAINAGE NOTES:
1. ALL MATERIALS AND CONSTRUCTION SHALL BE IN ACCORDANCE WITH MARION COUNTY STANDARDS AND
SPECIFICATIONS.
2. ALL EARTHWORK AND PLACEMENT OF FILL TO CONFORM TO THE MORE STRICT OF THE MARION COUNTY LAND
DEVELOPMENT CODE TECHNICAL SPECIFICATIONS OR THE GEOTECHNICAL REPORT.
3. ALL TRIMMING UNDERTAKEN ON A TREE PROTECTED BY PROVISIONS OF LAND DEVELOPMENT CODE SHALL BE PRUNED IN ACCORDANCE WITH THE AMERICAN NATIONAL STANDARDS INSTITUTE (ANSI) A-300 PRUNING
STANDARDS.
4. STAKED SILT FENCE SHALL BE INSTALLED PRIOR TO EARTHWORK OPERATIONS COMMENCING AND IS TO BE
MAINTAINED THROUGH PROJECT COMPLETION.
5. ALL DRIVEWAYS WITHIN THE PROJECT LIMITS ARE CONSTRUCTED OF STANDARD CONCRETE UNLESS OTHERWISE
NOTED ON THE PLANS.
6. EXISTING STORM PIPE, DRIVEWAY CULVERTS, AND STRUCTURES ARE INTENDED TO REMAIN. ANY STORM PIPES AND STRUCTURES REMOVED DURING CONSTRUCTION SHALL BE REPLACED WITH LIKE-KIND MATERIALS. ANY UTILITY INSTALLATION ENCROACHING WITHIN TWO FEET OF EXISTING STORM PIPE AND STRUCTURES ARE ASSUMED TO REQUIRE EXCAVATION, REMOVAL, AND REPLACEMENT OF EXISTING STORM PIPES AND STRUCTURES.
REFER TO TOPOGRAPHICAL SURVEY FOR PREEXISTING CULVERT INVERT ELEVATIONS FOR RESTORATION.
GENERAL NOTES:
1. ALL PRACTICABLE AND NECESSARY EFFORT SHALL BE TAKEN DURING CONSTRUCTION TO CONTROL AND PREVENT
EROSION AND TRANSPORT OF SEDIMENT MATERIAL TO INLETS, SURFACE DRAINS, WETLANDS AND LAKE AREAS.
THE CONTRACTOR SHALL BE RESPONSIBLE FOR ALL RESTORATION EFFORTS THAT MAY BE REQUIRED.
2. THE CONTRACTOR IS TO CONTROL ALL FUGITIVE DUST ORIGINATING ON THIS PROJECT BY WATERING OR OTHER METHODS AS REQUIRED AND/OR ACCEPTED BY THE OWNER AND/OR AUTHORIZED REPRESENTATIVE.
3. SPECIAL CARE SHALL BE TAKEN TO ENSURE THAT EXISTING TREES, THAT ARE NOT SPECIFIED TO BE REMOVED, REMAIN UNDAMAGED DURING CONSTRUCTION.
4. PRIOR TO BEGINNING WORK, THE CONTRACTOR SHALL EXPOSE ALL EXISTING UTILITIES TO BE EXTENDED OR CROSSED AND CONTACT THE ENGINEER FOR RESOLUTION OF ANY CONFLICTS BETWEEN FIELD CONDITIONS AND
CONSTRUCTION DOCUMENTS.
5. IT IS THE CONTRACTOR'S RESPONSIBILITY TO DETERMINE THE EXACT LOCATION OF THE UNDERGROUND UTILITIES PRIOR TO CONSTRUCTION IN THEIR VICINITY. THE CONTRACTOR SHALL NOTIFY "SUNSHINE" (1-800-432-4770) AND ALL UTILITY COMPANIES IN THE AREA FIVE (5) DAYS IN ADVANCE OF BEGINNING CONSTRUCTION.
6. DIGITAL OR ELECTRONIC REPRESENTATION OF THESE CONSTRUCTION PLANS DOES NOT CONSTITUTE A COORDINATE CONTROL MAP OR MATHEMATICALLY CONTROLLED INFORMATION FOR THE USE OF CONSTRUCTION STAKEOUT. IT IS THE RESPONSIBILITY OF THE CONTRACTOR AND/OR CONTRACTOR'S SURVEYOR TO ENSURE THAT ANY DIGITAL OR ELECTRONIC REPRESENTATION OF THESE PLANS IS IN COMPLETE CONFORMANCE WITH ALL OF THE NOTATIONS, SPECIFICATIONS, DETAILS AND OTHER DATA APPEARING ON OR AS MAY BE DERIVED FROM THESE
CONSTRUCTION PLANS.
7. CONTRACTOR IS RESPONSIBLE FOR PREPARING AND IMPLEMENTING MAINTENANCE OF TRAFFIC PLANS AS
REQUIRED.
8. CONTRACTOR RESPONSIBLE FOR REPAIR AND REPLACEMENT OF INFRASTRUCTURE / FACILITIES WITHIN THE
RIGHT-OF-WAY THAT ARE DAMAGED DURING CONSTRUCTION ACTIVITY.
9. NO BURNING IS PERMITTED ON THE PROJECT.
10. SIDEWALKS SHALL BE CONSTRUCTED OF NATURAL OR COLORED CONCRETE AT 3,000 PSI IN STRENGTH, FIBER REINFORCED, AND A MINIMUM OF FOUR INCHES (4") IN THICKNESS. AT DRIVEWAY CROSSINGS, THE THICKNESS
SHALL BE A MINIMUM OF SIX INCHES (6"), UNLESS OTHERWISE SPECIFIED.
11. UTILITY LINES OF ALL KINDS, INCLUDING, BUT NOT LIMITED TO, ELECTRIC POWER AND LIGHT, TELEPHONE AND TELEGRAPH, CABLE TELEVISION, WATER, SEWER, AND GAS SHALL BE CONSTRUCTED AND INSTALLED BENEATH THE SURFACE OF THE GROUND WITH EXCEPTION OF SERVICE PEDESTALS, TRANSFORMERS, JUNCTION BOXES, AIR RELEASE ASSEMBLIES, FIRE HYDRANTS, AND RELATED APPURTENANCES AS APPROVED BY ENGINEER.
12. THERE ARE NO KNOWN HISTORIC RESOURCES ON SITE. HOWEVER, IF, DURING CONSTRUCTION ACTIVITIES, ANY EVIDENCE OF HISTORIC RESOURCES INCLUDING, BUT NOT LIMITED TO, ABORIGINAL OR HISTORIC POTTERY, PREHISTORIC STONE TOOLS, ARROWHEADS, BONE OR SHELL TOOLS, HISTORIC TRASH PITS, OR HISTORIC BUILDING FOUNDATIONS ARE DISCOVERED, WORK SHALL COME TO AN IMMEDIATE STOP, AT THE OBSERVATION LOCATION AND THE ENGINEER NOTIFIED. THE LOCAL MUNICIPALITY AND THE FLORIDA DIVISION OF HISTORICAL RESOURCES (STATE HISTORIC PRESERVATION OFFICER) SHALL BE NOTIFIED WITHIN TWO WORKING DAYS ONCE
THE OBSERVATION IS CONFIRMED BY THE EOR.
13. IF DURING CONSTRUCTION ACTIVITIES ANY EVIDENCE OF THE PRESENCE OF STATE OR FEDERALLY PROTECTED PLANT AND/OR ANIMAL SPECIES IS DISCOVERED, LOCAL MUNICIPALITY AND APPLICABLE AGENCIES SHALL BE NOTIFIED WITHIN TWO WORKING DAYS OF THE PLANT AND/OR ANIMAL SPECIES FOUND ON THE SITE. ALL WORK IN THE AFFECTED AREA SHALL COME TO AN IMMEDIATE STOP UNTIL ALL PERTINENT PERMITS HAVE BEEN OBTAINED, AGENCY WRITTEN AUTHORIZATION TO COMMENCE ACTIVITIES HAS BEEN GIVEN, OR UNLESS
COMPLIANCE WITH STATE AND FEDERAL GUIDELINES CAN BE DEMONSTRATED.
14. SITE TRIANGLES SHALL BE UNOBSTRUCTED, AND SHALL BE INSPECTED AND MAINTAINED IN CONFORMANCE WITH FDOT DESIGN MANUAL SECTION 212.11.1 AND RELATED EXHIBITS, INCLUDING 212.11.6 TREES AND VEGETATION.
15. AS APPLICABLE, ALL MATERIALS AND CONSTRUCTION SHALL BE IN ACCORDANCE WITH THE LATEST EDITIONS OF:
A. MARION COUNTY LAND DEVELOPMENT CODE
B. FLORIDA DEPARTMENT OF TRANSPORTATION ROADWAY STANDARD PLANS.
C. FLORIDA DEPARTMENT OF TRANSPORTATION STANDARD SPECIFICATIONS FOR ROAD AND BRIDGE
CONSTRUCTION
17. UNSUITABLE MATERIAL FOR TRENCH BACKFILL SHALL BE DEFINED AS PLASTIC CLAYS, SILTS, MUCKS, CONTAMINATED SOILS, OR ROCK EXCAVATION. IN THE EVENT UNSUITABLE MATERIAL IS ENCOUNTERED, CONTRACTOR SHALL NOTIFY COUNTY AND ENGINEER FOR CONCURRENCE AND REMOVAL FROM SITE. LOCATIONS OF UNSUITABLE MATERIALS MAY REQUIRE TYPE A BEDDING PER MARION COUNTY DETAIL UT102 ON C7.02.
19. CONTRACTOR IS RESPONSIBLE FOR TEMPORARY SUPPORTING OVERHEAD UTILITIES. CONTRACTOR SHALL COORDINATE WITH DUKE ENERGY TO SUPPORT GUY LINES AND ANCHORS AND FOR ARRANGING POLE HOLDS OR
RELOCATIONS DURING PIPING INSTALLATIONS.
20. EXISTING TREES ON LIFT STATION SITE SHOWN TO BE OUTSIDE THE LIMITS OF CLEARING SHALL REMAIN AND
SHALL BE PROTECTED THROUGHOUT THE CONSTRUCTION.
SURVEY NOTES:
1. THE TOPOGRAPHIC SURVEY UPON WHICH THE PROJECT DESIGN IS BASED WAS PREPARED BY JCH CONSULTING
GROUP, INC. 426 SW 15TH STREET, OCALA, FL 34471.
2. BEARINGS AND COORDINATES SHOWN HEREON ARE BASED ON THE FLORIDA STATE PLANE COORDINATE SYSTEM, WEST ZONE, NORTH AMERICAN DATUM OF 1983 (NAD 83), WITH 2011 ADJUSTMENT, AS DERIVED FROM THE
FLORIDA DEPARTMENT OF TRANSPORTATION VIRTUAL REFERENCE STATION NETWORK.
3. SUBJECT TO RIGHTS OF WAY, RESTRICTIONS, EASEMENTS, AND RESERVATIONS OF RECORD. PUBLIC RECORDS
NOT SEARCHED BY JCH CONSULTING GROUP, INC.
4. RIGHT OF WAY FOR BLITCHTON ROAD AS SHOWN IS BASED ON FOUND MONUMENTATION, RIGHT OF WAY FOR N.W.
16TH LANE IS BASED ON GOLDEN HOLIDAY UNIT 2, AS PLAT THEREOF RECORDED IN PLAT BOOK "N", PAGE 38 OF
THE PUBLIC RECORDS OF MARION COUNTY, FLORIDA.
5. TOPOGRAPHIC DATA AND TREE LOCATIONS ARE BASED ON AREA AS SPECIFIED BY CLIENT.
6. VERTICAL DATUM IS BASED ON NATIONAL GEODETIC SURVEY CONTROL POINT E 427, ELEVATION 83.32' (NAVD 1988).
7. THE PROPERTY IN THE VICINITY OF THE PROJECT AREA APPEARS TO LIE IN ZONE "X" (AN AREA DETERMINED TO BE OUTSIDE THE 0.2% ANNUAL CHANCE FLOODPLAIN), ACCORDING TO FLOOD INSURANCE RATE MAP NO.
12083C0508E (FIRM) AS PREPARED BY THE FEDERAL EMERGENCY MANAGEMENT AGENCY (FEMA), EFFECTIVE APRIL 19, 2017.
8. NOT ALL UTILITIES WERE FIELD VERIFIED FOR THE TOPOGRAPHIC SURVEY. THEREFORE, THE INFORMATION CONTAINED ON THE DRAWINGS ARE BEST AVAILABLE INFORMATION RECEIVED FROM UTILITIES AT THE TIME OF
DESIGN. THE FOLLOWING UTILITIES ARE KNOWN TO BE WITHIN THE PROJECT LIMITS:
· LUMEN
· CITY OF OCALA (WATER AND SEWER)
· CITY OF OCALA ELECTRIC (TRANSMISSION AND DISTRIBUTION)
· DUKE ENERGY (TRANSMISSION AND DISTRIBUTION)
· MARION COUNTY UTILITIES (WATER AND SEWER)
· TECO PEOPLES GAS
12. ANY PUBLIC LAND CORNER WITHIN THE LIMITS OF CONSTRUCTION IS TO BE PROTECTED. IF A CORNER MONUMENT IS IN DANGER OF BEING DESTROYED AND HAS NOT BEEN PROPERLY REFERENCED THE CONTRACTOR SHALL EMPLOY THE SERVICES OF A PROFESSIONAL REGISTERED SURVEYOR TO REESTABLISH THE MONUMENT AND REFERENCES AND PROPERLY NOTIFY ALL PUBLIC AGENCIES AND FILE ALL REQUIRED DOCUMENTATION ALL AT NO
ADDITIONAL COST TO THE OWNER.
13. THE CONTRACTOR'S SURVEYOR SHALL REESTABLISH ALL ROAD AND RIGHT OF WAY CONTROL BEFORE STARTING
CONSTRUCTION, IF APPLICABLE.
14. EXISTING UTILITIES SHOWN IN PROFILE VIEW ARE PROVIDED AS INFORMATION ONLY AND HAVE NOT BEEN FIELD
VERIFIED.
T:\208 Marion County\69_Golden Holiday Off-Site Sewer\dwg\_PE\03 NOTES SHEET.dwg
G O
LD
E
N H
O
LI
D A
Y W
W
TF
D E
C O
M M
IS
S
IO
N
IN
G
G E
N E
R A
L N
O
TE
S
Ardurra Group, Inc.
925 S.E. 17th Street, Suite A
Ocala, Florida 34471 Phone: (352) 861-7799 www.Ardurra.com License #26531
18OFC1.02
FDOT NOTES:
1. MARION COUNTY UTILITIES WILL BE CONSTRUCTING THIS PROJECT WITH A NEW PUMP STATION AND THE
PROPOSED SEWER FORCEMAIN WITHIN FDOT RIGHT OF WAY. AFTER COMPLETION, MCU WILL TRANSFER OWNERSHIP, OPERATION, AND MAINTENANCE RESPONSIBILITIES TO CITY OF OCALA FOR THE PROPOSED
FORCEMAIN WITHIN FDOT RIGHT OF WAY.
Approved 2025-H-595-00242
Nicole Aiton 1/8/2026
MChauncey
THIS ITEM HAS BEEN DIGITALLY SIGNED AND SEALED BY MITCHELL R. CHAUNCEY, P.E. ON THE DATE ADJACENT TO THE SEAL. THE SIGNATURE MUST BE VERIFIED ON ANY ELECTRONIC COPIES.
N.W. 32ND AVENUE
EXISTING WWTF SITE
PROPOSED LS SITE
PROPOSED 3"
HDPE FORCEMAIN
CONNECT TO
EXISTING MANHOLE
21748-000-00
LINCOIN MEMORIAL GARDENS OF OCALA
21863-000-00
RURAL KING
21746-000-00
D & L REAL ESTATE
INVESTMENT LLC
21875-000-00
WELCH SANDRA COHEN
21839-000-00
TRIPLE V PROPERTIES
LLC 21885-000-00
CITY OF OCALA
21748-000-00
LINCOIN MEMORIAL GARDENS OF OCALA
21748-000-00
LINCOIN MEMORIAL GARDENS OF OCALA
21699-000-28
BLITCHTON OCALA LP
OTTER SELF STORAGE
22147-000-00
INTERIAN PROPERTIES LLC
1-
0-
HM
E
PL
AS
TI
CS
L
LC
21886-000-00
SEPIDEH BALDWIN LVG
TRUST
(FAITH CEMETARY)
21888-000-00
SEPIDEH BALDWIN LVG
TRUST
9-
1-
M
ED
IN
A
PE
TE
R
2-
0-
SO
U
TH
ER
N
IM
PR
ES
SI
O
N H
O M
ES
L
LC
21889-008-00
WILLIAMS DAVID E.
21889-006-00
WILLIAMS DAVID E.
21889-007-00
DAVID MEDINA
5-
1-
IN
TE
RI
AN
P
RO
PE
RT
IE
S
LL
C
9-
0-
W
EA
TH
ER
S
AD
JU
ST
M
EN
T
CO
21741-000-00
WAC INC
21741-001-00
WEATHERS
ADJUSTMENT CO
21699-000-33
ROBLES GARY M
2172-0019-33
CITY OF OCALA
2172-019-000
MARION COUNTY
21739-000-00
THE CHAPEL OCALA INC
21739-001-00
GENERATIONS SEVEN
INC
21744-000-00
KLEIN H RANDOLPH REV
TRUST
21839-001-00
TRIPLE V PROPERTIES LLC
(SUNBELT RENTALS)
21699-000-27
SHOWCASE INVESTMENT GROUP LLC
(BUTLER INSURANCE GROUP)
21877-000-00
WELCH SANDRA
21906-000-00
KLEIN H RANDOLPH REV
TRUST
21873-000-00
(TRI-COUNTY METALS)
21848-000-00
KING MARY ROSETTA
EST
21889-003-00
BRYANT BARBARA M ET AL N
.W . 2
7T H
AV
EN
U E
N.W. 16TH LANE
SHEET C3.04
SHEET C3.02
SHEET C3.03
SHEET C3.05
N.W. OLD BLITCHTON ROAD
U.S. HIGHW
AY 27
(N.W
. BLITCHTON ROAD)
21748-000-00
LINCOIN MEMORIAL GARDENS OF OCALA
SHEET C3.01
N O
D
A
TE
R E
V
IS
IO
N
B Y
DATE:
JOB NO:
12/08/2025
208.69
MARION COUNTY UTILITIES
11800 SE US HWY 441
BELLEVIEW, FL 34420
352-307-6000
A
B
C
D
E
F
G
H
2 3 4 5 6 7 8 9 10 11 12
1 2 3 4 5 6 7 8 9 10 11 12
SE
CT
IO
N
1&
, T
W P.
6S
,1 5S
, R N
G.
3E , D
AT
U
M : F
L8 3.
W F-
N
AV
D.
T:\208 Marion County\69_Golden Holiday Off-Site Sewer\dwg\_PE\04 KEY MAP.dwg
G O
LD
E
N H
O
LI
D A
Y W
W
TF
D E
C O
M M
IS
S
IO
N
IN
G
K E
Y M
A P
PERMIT PLANS
12/08/2025
Ardurra Group, Inc.
925 S.E. 17th Street, Suite A
Ocala, Florida 34471 Phone: (352) 861-7799 www.Ardurra.com License #26531
SCALE: FEET
200'100'
(22" x 34" PLOT) SCALE: 1"=100' (11" x 17" PLOT) SCALE: 1"=200'
18OFC2.01
NOTE:
1. US 27 IS F.D.O.T. MAINTAINED.
ALL OTHER ROADS SHOWN ARE
CITY OF OCALA MAINTAINED.
Approved 2025-H-595-00242
Nicole Aiton 1/8/2026
MChauncey
THIS ITEM HAS BEEN DIGITALLY SIGNED AND SEALED BY MITCHELL R. CHAUNCEY, P.E. ON THE DATE ADJACENT TO THE SEAL. THE SIGNATURE MUST BE VERIFIED ON ANY ELECTRONIC COPIES.
APPARENT RIGHT
OF WAY
12'X6' HORIZONTAL
DIRECTIONAL BORE PIT
BEGIN DIRECTIONAL BORE
STA: 56+20.70
OFF: 4.25' LT.
PROPOSED (2) 265' OF 4" PVC
CONDUIT FOR NEW 3 PHASE ELECTRIC
SERVICE. CONDUCTORS TO BE
PROVIDED AND INSTALLED BY CITY OF
OCALA.
PROPOSED 3 PHASE
TRANSFORMERS
NW 16th LnNW nd A ve
APPARENT RIGHT
OF WAY
0'
1.
5'
EDGE OF CURB
6.
0'
BEGIN FDOT
PERMITTED WORK
US Hwy 27 1.9
SOIL BORING #1
WM
WM
WM
WM WM
PROPOSED 200' OF 2" SCH 40 PVC
WM. SEE SHEET C5.01
EXISTING GROUND
ALONG ALIGNMENT
ROADWAY
EXISTING GROUND
ALONG ALIGNMENT
ROADWAY
ARV
AP
PA
RE
N
T
RI
GH
T
O F
W
AY
PR
OPO
SE
D 3
PH
AS
E
TR
AN
SF
ORM
ER
S
AP
PA
RE
N
T
RI
GH
T
O F
W
AY
100' 1.5'
6.0'
BE
GI
N F
DO
T
PE
RM
IT
TE
D W
O
RK
N O
D
A
TE
R E
V
IS
IO
N
B Y
DATE:
JOB NO:
1/5/2026
208.69
MARION COUNTY UTILITIES
11800 SE US HWY 441
BELLEVIEW, FL 34420
352-307-6000
A
B
C
D
E
F
G
H
2 3 4 5 6 7 8 9 10 11 12
1 2 3 4 5 6 7 8 9 10 11 12
SE
CT
IO
N
1&
, T
W P.
6S
,1 5S
, R N
G.
3E , D
AT
U
M : F
L8 3.
W F-
N
AV
D.
T:\208 Marion County\69_Golden Holiday Off-Site Sewer\dwg\_PE\05 PLAN & PROFILE.dwg
G O
LD
E
N H
O
LI
D A
Y W
W
TF
D E
C O
M M
IS
S
IO
N
IN
G
P
LA
N
P R
O
FI
LE
PERMIT PLANS
1/5/2026
Ardurra Group, Inc.
925 S.E. 17th Street, Suite A
Ocala, Florida 34471 Phone: (352) 861-7799 www.Ardurra.com License #26531
18OFC3.01
LEGEND:
APPARENT RIGHT
OF WAY
APPARENT RIGHT
OF WAY
APPARENT RIGHT
OF WAY
APPARENT RIGHT
OF WAY
PROPOSED LIFT STATION
SITE SEE SHEET C5.01
END DIRECTIONAL DRILL
STA: 52+25
OFF: 48' LT.
12'X6' HORIZONTAL
DIRECTIONAL BORE PIT
1" FM ARV
(OFFSET)
3" 45° BEND
3" 45° BEND
3" 45° BEND
1" FM ARV
(OFFSET)
Approved 2025-H-595-00242
Nicole Aiton 1/8/2026
MChauncey
THIS ITEM HAS BEEN DIGITALLY SIGNED AND SEALED BY MITCHELL R. CHAUNCEY, P.E. ON THE DATE ADJACENT TO THE SEAL. THE SIGNATURE MUST BE VERIFIED ON ANY ELECTRONIC COPIES.
APPARENT RIGHT
OF WAY
12'X6' HORIZONTAL
DIRECTIONAL BORE PIT
BEGIN DIRECTIONAL BORE
STA: 56+20.70
OFF: 4.25' LT.
BEGIN DIRECTIONAL BORE
STA: 56+58.26
OFF: 1.75' LT.
EXISTING TELEPHONE VAULT
(NOT FIELD VERIFIED)
NW 16th Ln
N W
2n d Av e
APPARENT RIGHT
OF WAY
0'
1.
5'
EDGE OF CURB
6.
0'
BEGIN FDOT
PERMITTED WORK
END FDOT
PERMITTED WORK
US Hwy 27
1.
9'
SOIL BORING #2
PROPOSED 3" HDPE HORIZONTAL
DIRECTIONAL DRILL
EXISTING GROUND
ALONG ALIGNMENT
ROADWAY
15° ENTRY ANGLE
15° EXIT ANGLE
15° ENTRY ANGLE
PROPOSED 3" HDPE HORIZONTAL
DIRECTIONAL DRILL
ARV
EXISTING TELEPHONE VAULT
(DEPTH NOT FIELD VERIFIED)
BEGIN FDOT
PERMITTED
WORK
N O
D
A
TE
R E
V
IS
IO
N
B Y
DATE:
JOB NO:
12/9/2025
208.69
MARION COUNTY UTILITIES
11800 SE US HWY 441
BELLEVIEW, FL 34420
352-307-6000
A
B
C
D
E
F
G
H
2 3 4 5 6 7 8 9 10 11 12
1 2 3 4 5 6 7 8 9 10 11 12
SE
CT
IO
N
1&
, T
W P.
6S
,1 5S
, R N
G.
3E , D
AT
U
M : F
L8 3.
W F-
N
AV
D.
T:\208 Marion County\69_Golden Holiday Off-Site Sewer\dwg\_PE\05 PLAN & PROFILE.dwg
G O
LD
E
N H
O
LI
D A
Y W
W
TF
D E
C O
M M
IS
S
IO
N
IN
G
P
LA
N
P R
O
FI
LE
PERMIT PLANS
12/9/2025
Ardurra Group, Inc.
925 S.E. 17th Street, Suite A
Ocala, Florida 34471 Phone: (352) 861-7799 www.Ardurra.com License #26531
18OFC3.02
EXISTING 16" WATERMAIN
EXISTING 2" FIBER OPTIC
CONDUIT
PROPOSED 3" FM TO
RUN ON BACK OF
EXISTING 6' SIDEWALK
VIA HDD INSTALLATION
LEGEND:
RESTORE EXISTING
CROSSWALK STRIPING
DETAIL 'A'
SCALE: 1"=10'
END DIRECTIONAL DRILL
STA: 52+25.32
OFF: 48.39' LT.
12'X6' HORIZONTAL
DIRECTIONAL BORE PIT
1" FM ARV
(OFFSET)
1" FM ARV
(OFFSET)
1" FM ARV
(OFFSET)
12'x6' HORIZONTAL
DIRECTIONAL BORE PIT
REMOVE AND REPLACE
TYPE D CURB
US Hwy 27
Approved 2025-H-595-00242
Nicole Aiton 1/8/2026
MChauncey
THIS ITEM HAS BEEN DIGITALLY SIGNED AND SEALED BY MITCHELL R. CHAUNCEY, P.E. ON THE DATE ADJACENT TO THE SEAL. THE SIGNATURE MUST BE VERIFIED ON ANY ELECTRONIC COPIES.
UTILITIES
CALL
BEFORE
DIGGING
DISTANCE
TO MAIN
UTILITIES
N O
D
A
TE
R E
V
IS
IO
N
B Y
DATE:
JOB NO:
12/8/2025
208.69
MARION COUNTY UTILITIES
11800 SE US HWY 441
BELLEVIEW, FL 34420
352-307-6000
A
B
C
D
E
F
G
H
2 3 4 5 6 7 8 9 10 11 12
1 2 3 4 5 6 7 8 9 10 11 12
SE
CT
IO
N
1&
, T
W P.
6S
,1 5S
, R N
G.
3E , D
AT
U
M : F
L8 3.
W F-
N
AV
D.
T:\208 Marion County\69_Golden Holiday Off-Site Sewer\dwg\_PE\14 DETAILS.dwg
G O
LD
E
N H
O
LI
D A
Y W
W
TF
D E
C O
M M
IS
S
IO
N
IN
G
D E
TA
IL
S
PERMIT PLANS
12/8/2025
Ardurra Group, Inc.
925 S.E. 17th Street, Suite A
Ocala, Florida 34471 Phone: (352) 861-7799 www.Ardurra.com License #26531
18OFC7.01Approved 2025-H-595-00242
Nicole Aiton 1/8/2026
MChauncey
THIS ITEM HAS BEEN DIGITALLY SIGNED AND SEALED BY MITCHELL R. CHAUNCEY, P.E. ON THE DATE ADJACENT TO THE SEAL. THE SIGNATURE MUST BE VERIFIED ON ANY ELECTRONIC COPIES.
D
A
TE
R E
V
IS
IO
N
B Y
DATE:
JOB NO:
12/8/2025
208.69
MARION COUNTY UTILITIES
11800 SE US HWY 441
BELLEVIEW, FL 34420
352-307-6000
A
B
C
D
E
F
G
H
2 3 4 5 6 7 8 9 10 11 12
1 2 3 4 5 6 7 8 9 10 11 12
SE
CT
IO
N
1&
, T
W P.
6S
,1 5S
, R N
G.
3E , D
AT
U
M : F
L8 3.
W F-
N
AV
D.
18OF
G O
LD
E
N H
O
LI
D A
Y W
W
TF
D E
C O
M M
IS
S
IO
N
IN
G
D E
TA
IL
S
C7.02
PERMIT PLANS
12/8/2025
Ardurra Group, Inc.
925 S.E. 17th Street, Suite A
Ocala, Florida 34471 Phone: (352) 861-7799 www.Ardurra.com License #26531
Approved 2025-H-595-00242
Nicole Aiton 1/8/2026
MChauncey
THIS ITEM HAS BEEN DIGITALLY SIGNED AND SEALED BY MITCHELL R. CHAUNCEY, P.E. ON THE DATE ADJACENT TO THE SEAL. THE SIGNATURE MUST BE VERIFIED ON ANY ELECTRONIC COPIES.
D
A
TE
R E
V
IS
IO
N
B Y
DATE:
JOB NO:
12/8/2025
208.69
MARION COUNTY UTILITIES
11800 SE US HWY 441
BELLEVIEW, FL 34420
352-307-6000
A
B
C
D
E
F
G
H
2 3 4 5 6 7 8 9 10 11 12
1 2 3 4 5 6 7 8 9 10 11 12
SE
CT
IO
N
1&
, T
W P.
6S
,1 5S
, R N
G.
3E , D
AT
U
M : F
L8 3.
W F-
N
AV
D.
T:\208 Marion County\69_Golden Holiday Off-Site Sewer\dwg\_PE\17 MOT INDEX SHEETS.dwg
G O
LD
E
N H
O
LI
D A
Y W
W
TF
D E
C O
M M
IS
S
IO
N
IN
G
M O
T D
E
TA
IL
S
PERMIT PLANS
12/8/2025
Ardurra Group, Inc.
925 S.E. 17th Street, Suite A
Ocala, Florida 34471 Phone: (352) 861-7799 www.Ardurra.com License #26531
18OFC8.01Approved 2025-H-595-00242
Nicole Aiton 1/8/2026
MChauncey
THIS ITEM HAS BEEN DIGITALLY SIGNED AND SEALED BY MITCHELL R. CHAUNCEY, P.E. ON THE DATE ADJACENT TO THE SEAL. THE SIGNATURE MUST BE VERIFIED ON ANY ELECTRONIC COPIES.
D
A
TE
R E
V
IS
IO
N
B Y
DATE:
JOB NO:
12/8/2025
208.69
MARION COUNTY UTILITIES
11800 SE US HWY 441
BELLEVIEW, FL 34420
352-307-6000
A
B
C
D
E
F
G
H
2 3 4 5 6 7 8 9 10 11 12
1 2 3 4 5 6 7 8 9 10 11 12
SE
CT
IO
N
1&
, T
W P.
6S
,1 5S
, R N
G.
3E , D
AT
U
M : F
L8 3.
W F-
N
AV
D.
T:\208 Marion County\69_Golden Holiday Off-Site Sewer\dwg\_PE\17 MOT INDEX SHEETS.dwg
G O
LD
E
N H
O
LI
D A
Y W
W
TF
D E
C O
M M
IS
S
IO
N
IN
G
M O
T D
E
TA
IL
S
PERMIT PLANS
12/8/2025
Ardurra Group, Inc.
925 S.E. 17th Street, Suite A
Ocala, Florida 34471 Phone: (352) 861-7799 www.Ardurra.com License #26531
18OFC8.02Approved 2025-H-595-00242
Nicole Aiton 1/8/2026
MChauncey
THIS ITEM HAS BEEN DIGITALLY SIGNED AND SEALED BY MITCHELL R. CHAUNCEY, P.E. ON THE DATE ADJACENT TO THE SEAL. THE SIGNATURE MUST BE VERIFIED ON ANY ELECTRONIC COPIES.
Date Taken: 10/24/2025
US-27 (SR 500) North Right of Way from NW 32nd Ave to Old Blitchton Road
Approved 2025-H-595-00242
Notice required a minimum of two (2) business days prior to starting work
Notify the designated FDOT Representative-
Inspector Raul Cepeda (352) 672-7299 raulc@oasisiam.com
Utility Permit Start Work Notice
FDOT Permit Number:
Contractor/Company:
Field Contact Name:
Phone number:
Start Work date:
Planned End Work date:
State Road Number:
Special Instructions:
1. The UAO and/or Utility Builder shall commence actual construction in good faith within sixty
(60) calendar days after approval of the permit application. Unless otherwise noted.
2. Call Sunshine 811 for utility location services 48 hours (2 business days) prior to beginning operation at 1-800-432-4770.
3. Non-located/unmarked FDOT ITS facilities, including fiber optic communication and traffic control signal loops/devices, may exist within the project limits; make temporary repairs to any damage to a facility within four (4) hours of the occurrence. If assistance is required regarding ITS facilities, contact the FDOT Traffic Operations ITS Manager, Daniel Simpson at (386) 785-3980, daniel.simpson@dot.state.fl.us or at (386) 943-5000. Coordination for any damage to ITS Facilities should be done with Jennifer Sardonini (386) 785-3764.
4. Always keep a copy of the approved permit package on the jobsite. Contact the designated FDOT Representative listed on permit with construction status.
5. If the beginning date is more than 60 calendar days from the date of approval, the UAO and/or Utility Builder must review the permit with the FDOT Approving Engineer listed to make sure no changes have occurred to the transportation facility that would affect the permit’s continued approval.
6. Once the project is constructed, submit As-Built plans (if construction differs from approved plan), bore logs (if a bore was conducted), and the Engineer’s As-Built Certification (page 3 of the permit package) to One Stop Permitting (OSP) within 15 calendar days of project completion.
Refer to UAM Section 2 for general responsibilities. Use of this form is optional.
Call Ocala Operations (352) 620-3000 or send this form to D5-595Permits@dot.state.fl.us to initiate work Approved
2025-H-595-00242 Nicole Aiton
1/8/2026 mailto:D5-595Permits@dot.state.fl.us
| 2026-01-05T16:22:29-0500 | |
| Mitchell R Chauncey | |
| I have reviewed this document |
| Text1: |
| Text2: |
| Text3: |
| Text4: |
| Text5: mm/dd/yy |
| Text6: mm/dd/yy |
| Dropdown1: [ ] |
File details come from the government source that posted it. Updated .