11-AS-107 PVS Roof Ladder.pdf
PDF 511 KB Posted
- Attached to
- Z2DA--* T4 554-23-108 Install Ladders and Platforms in Mechanical Areas (VA-23-00006335)
- Solicitation number
- 36C25923Q0086
View the file
Other files
| File | Type | Posted |
|---|---|---|
| 36C25923Q0086 0005.docx | DOCX document | |
| Pictures Question 11.docx | DOCX document | |
| Questions Set 2.docx | DOCX document | |
| Ladder.pdf | ||
| PSN.docx | DOCX document | |
| 36C25923Q0086 0004.docx | DOCX document | |
| 36C25923Q0086 0003.docx | DOCX document | |
| S04-Site Visit Attendance.pdf | ||
| Questions.docx | DOCX document | |
| 36C25923Q0086 0002.docx | DOCX document | |
| Site Visit Meeting Doc.docx | DOCX document | |
| 36C25923Q0086 0001.docx | DOCX document | |
| Fisher House Mech Room Ladder.pdf | ||
| XX.AS.411 Bldg D F Roof Access Detail.pdf | ||
| 03-PP-100-B DS-102 Vault Ladder.pdf | ||
| Bldg D Upper Roof Access 2.jpg | JPG image | |
| 13-PP-102-A Vault Lid Replacement.pdf | ||
| Combined Spec.pdf | ||
| PVS Elevator Machine Room on Roof.jpg | JPG image | |
| 36C25923Q0086.docx | DOCX document | |
| Bldg F Upper Roof Access.jpg | JPG image | |
| Bldg D Upper Roof Access.jpg | JPG image | |
| 03-AS-104-B Bldg D Upper Roof Access.pdf | ||
| 03-AS-104-A Bldg F Upper Roof Access.pdf |
Show all 24
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
11-AS-202
11-AS-201
11-AS-301
11-AS-301
11-AS-302
11-AS-302
11-AS-302
11-AS-302
11-AS-202
RD OD
11-AS-107
11-AS-201
K
J
H
G
F
E
D
C
B
A
L
1/ 4"
TAPERED
INSULATION
CRICKET
11-AS-310
VALLEY
VALLEY
RIDGE
XX.AS.581
'-0
'-0
'-0
'-0
0'
-0
XX.AS.581
XX.AS.581
EL. 164' - 0"
EL. 162' - 9"
EL. 164' - 0"
EL. 162' - 9"
EL. 164' - 0"
XX.AS.582
6TYP.
1/ 4"
1/ 4"
1/ 4"
1/ 4"
1/
4"
XX.AS.582
XX.AS.582
CLS
TYP.
DB
TYP.
RS21
RS23
RS21
CLS
TYP.
11-AS-202
15'-0" 30'-0" 30'-0" 30'-0" 30'-0" 30'-0" 30'-0" 30'-0" 30'-0" 15'-0"
270'-0"
TAPERED
INSULATION
CRICKET TYP.
DB
XX.AS.581
XX.AS.581
1/ 4"
1/
4"
1/ 4"
1/
4"
1/ 4"
1/
4"
1/ 4"
1/
4"
RE:
ELECTRICAL
FOR PV
LAYOUT TYP.
XX.AS.582
RE: DETAIL 15/XX.AS.581
FOR BIPV SUPPORT DETAIL
DB
XX.AS.581
XX.AS.581
XX.AS.581
EL
. 1
5' -6
" 4'-0"
3' -6
5'-0" 10'-0" 5'-0" 25'-0" 5'-0" 25'-0" 5'-0" 25'-0" 5'-0" 25'-0" 5'-0" 25'-0" 5'-0" 25'-0" 5'-0" 25'-0" 5'-0" 25'-0" 5'-0" 10'-0"
POSTS FOR CLS, TYPICAL.
RE: XX.QM.502, N/XX.SS.812,
AND 19/XX.AS.582.
DIMENSIONS AT NORTH APPLY
TO SOUTH. DIMENSIONS AT
WEST APPLY TO EAST.
XX.AS.582
5'-0" 10'-0" 5'-0" 10'-0"
6' -0
9'
-0
'-0
'-0
'-0
'-0
'-0
'-0
'-0
'-0
'-0
'-0
9' -0
6'
-0
11-AS-310
Sim
11-P7-A4-01
ELEV MACH RM
A
EL. 165' - 2"
A
A
XX.AS.581
XX.AS.581
MTL61
GL83
29'-6"
'-5
1'
-6
A6
11.AS.403X
11-P7-ST-3
STAIR 3
FEC
ARCHITECTURAL NOTES:
1. ALL SPOT ELEVATIONS SHOWN INSIDE THE BUILDING ARE TO THE TOP
OF STRUCTURAL TOPPING SLAB UNLESS NOTED OTHERWISE.
2. ALL FLOOR PLAN DIMENSIONS TO MASONRY ARE NOMINAL DIMENSIONS
UNLESS NOTED AS ACTUAL.
3. SEE THE QP DRAWINGS IN VOLUME 6 FOR ALL STRIPING AND PARKING
CONTROL DIMENSIONS, SIGNAGE, BOLLARDS AND DETAILS.
4. ALL EXPOSED STRUCTURAL STEEL AND METAL DECK TO BE PAINTED
P51 WITH SURFACE PREP EPSS U.O.N.
5. REFER TO 11.QP.610 & 11.QP.701 FOR BOLLARD DETAILS NOT SHOWN IN
QP DRAWINGS.
6. REFER TO ‘FLS’ DRAWINGS FOR RATED WALL, EGRESS, AND CODE
COMPLIANCE INFORMATION.
7. MAINTAIN FIRE RATING OF WALLS AROUND FIRE EXTINGUISHER AND
FIRE VALVE CABINETS AND OTHER RECESSED ITEMS.
8. REFER TO SHEET 00.AI.002 FOR DIMENSIONING INFORMATION. ALL
DIMENSIONS ARE TO FINISH FACE OF WALL UNLESS NOTED
OTHERWISE. ALL DOORS SHALL BE LOCATED 4" OFF AN ADJACENT
PERPENDICULAR WALL UNLESS NOTED OTHERWISE. MINIMUM
REQUIRED ADA MANEUVERING CLEARANCE DIMENSIONS AT DOORS
SHALL GOVERN. REFER TO TYPICAL DOOR CLEARANCE DIAGRAM ON
SHEET 00.AI.002.
9. REFER TO SHEET XX.AI.786 FOR ELEVATOR CAB FINISHES
ROOFING SYSTEM LEGEND
CODE DESCRIPTION
MEMBRANE ON DECK
DAVIT BASE
RS21
DB
ROOF DETAIL NOTES;
ALL ROOF PENETRATION DETAILS
: 1 TO 4 - XX.AS.562 AND 19/XX.AS.582
BUILDING MAINTENANCE & FALL
PROTECTION SYSTEM DETAILS
: 5 TO 7 - XX.AS.562 AND 19/XX.AS.582
LIGHTNING PROTECTION ROD DETAIL
: 8 - XX.AS.562 AND ELECTRICAL DWGS.
CLS CONTINUOUS LIFE LINE
SYSTEM
BMRS BUILDING MAINTENANCE
RAIL SYSTEM
MEMBRANE ON INSULATIONRS23
ROOF HATCHROH01
11 12 08 09 13
03040506
Drawing Number
Building Number
Project NumberProject Title
Location
Date Checked Drawn
Drawing Title
Approved: Project Director
Key PlanCONSULTANTS:
DateRevisions
1 2 3 4 5 6 7 8 9 10 11 12
D
C
B
A
554-501REPLACEMENT MEDICAL CENTER
FACILITY, EASTERN COLORADO HEALTH
CARE SYSTEM
AURORA, COLORADO
N
C O
N
R
ES
D
AT
IB
S
IB
N
EN
C
C
LC
C
BN
C
BC
C
BS
PS
N
PV
N
PV
S
13 14
1 2 3 4 5 6 7 8 9 10 11 12 13 14
E th re e th irt y-se co nd in ch o ne fo ot
OFFICE OF
CONSTRUCTION
AND FACILITIES
MANAGEMENT
ARCHITECT/ENGINEERS:Professional Seal
6/
/2
:4 4:
A
M C
:\U se rs \C
AD
U se r 2
\D oc um en ts \A
S-
PS
N _c ha rlo tte .b la ck w oo d.
rv t
11-AS-107
ROOF PLAN
PARKING STAFF (NORTH)
08/31/2012
NORTH
0' 4' 12' 24' 36'0' 4' 12' 24' 36' 3/32" = 1'-0"1 ROOF LEVEL PLAN
3/32" = 1'-0"2
PARTIAL ELEVATOR MACHINE
ROOM LEVEL PLAN
VHAECHBlehmM Callout INSTALL 13' LADDER TO ACCESS MACHINE ROOM ROOF - MIDDLE TIE OFF RAIL OR CAGE REQUIRED
Sheets: 11-AS-107 - ROOF PLAN
File details come from the government source that posted it. Updated .