This document is an Asbestos Containing Material (ACM) and Hazardous Materials Inspection Report prepared by Red Cedar Consulting for the City of Jackson, Michigan, regarding a property located at 1004 Greenwood Avenue. The inspection, completed on September 10, 2025, was conducted to comply with United States Environmental Protection Agency (USEPA) and Occupational Safety and Health Administration (OSHA) requirements for demolition and renovation. The report details the findings of a comprehensive inspection of a 1,900-era residential structure, identifying various asbestos-containing materials that must be abated prior to demolition, including HVAC duct wrap, window glazing, and exterior Transite siding. The property is a 0.26-acre residential parcel with an approximately 1,862 square foot building containing multiple living spaces, kitchens, bathrooms, and bedrooms.

The inspection revealed seventeen samples of suspect ACM, with specific recommendations for removal before demolition activities can commence. Hazardous materials identified include a fire extinguisher and two automobile tires that require proper disposal. The project is funded through a Community Development Block Grant (CDBG) and will require a Notification of Intent to Renovate/Demolish to be filed with the Michigan Department of Environmental Quality at least 10 working days prior to any activities. Asbestos abatement must be performed by a certified contractor licensed to complete the work, following OSHA and USEPA standards. The demolition project aims to clear the site, terminate utility services, and restore the property to a smooth grade, with potential implications for neighborhood redevelopment and economic opportunities for local businesses.

Text of this file

1004 Greenwood Ave- CDBG funded demolition

From
Brian Taylor
To
Kari Kerstetter
Cc
Cory Mays; Shannon Williams; Shane LaPorte
Recipients
KKerstetter@cityofjackson.org; cmays@cityofjackson.org; swilliams@cityofjackson.org; slaporte@cityofjackson.org

Good morning Kari, We need to seek bids for this CDBG funded demolition project.

Please have bids returned in 1 week or whatever date is convenient for you and list that all work to be completed no later than December 18, 2025.

If you have any questions, please let me know

Thank you, Brian Taylor

Chief Building Official

517-795-9902- cell btaylor@cityofjackson.org

Online Payment Building Department Search | City of Jackson | BS&A Online (bsaonline.com)

1004 Greenwood Ave. ACM and Haz Materials Inspection 092625.pdf

P.O. Box 13216

Lansing, MI 48901

Phone: 888.449.4566

Fax: 888.448.8739 www.redcedarconsulting.net

September 26, 2025

Mr. Brian Taylor

City of Jackson

Community Development Department

Jackson, MI 49202

RE: Asbestos Containing Material and Hazardous Materials Inspection

1004 Greenwood Ave. Jackson, MI 49201

Parcel ID: 4-121500000

Dear Mr. Taylor:

Red Cedar Consulting has completed an asbestos-containing material (ACM) and hazardous materials inspection at 1004 Greenwood Ave. Jackson, Michigan (Subject Property). This inspection was completed at the request of the City of Jackson to comply with the United States Environmental

Protection Agency (USEPA) requirements for demolition and renovation set forth under the National

Emissions Standards for Hazardous Air Pollutants (NESHAP, 40 CFR Part 61). This inspection was also completed to comply with the Occupational Safety and Health Administration (OSHA) Asbestos

Standards for Construction (29 CFR 1926.1101) which limits employee exposure to asbestos.

SUBJECT PROPERTY

The Subject Property is comprised of a 0.26-acre residential parcel which contains an approximate 1,862 square foot residential building (the Building) constructed in 1900. The Building was constructed on a concrete basement with two aboveground floors. The exterior walls of the Building were finished with

Transite siding while the roof was sealed with multiple layers of roofing materials. The Building can be further divided into two living rooms, two kitchens, two bathrooms, two bedrooms, a front and a rear entry on the first floor while the second floor contains two living rooms, two kitchens, two bathrooms and one bedroom.

VISUAL INSPECTION AND SAMPLING

Asbestos Containing Materials Inspection

Darrell DeMasters of Red Cedar Consulting (Red Cedar), accredited State Of Michigan/EPA Asbestos

Building Inspector (Accreditation Number A31159) who completed training per the Michigan Asbestos

Workers Accreditation Act 440, completed an inspection of the Subject Property on September 10, 2025, for suspected asbestos containing building materials.

Project No.: 12-1027

Parcel ID: 1004 Greenwood Ave.

This inspection, and subsequent sample collection was completed in accordance with the USEPA

Asbestos Hazard Emergency Response Act (AHERA) (40 CFR Part 763) assessment and sampling protocol.

During the completion of the inspection, each area of the Subject Property was visually inspected for asbestos containing building materials (ACBM). Following the completion of the visual inspection, Red

Cedar staff identified each suspect area of friable and non-friable ACBM and sorted them into one of three homogenous categories for sampling purposes. AHERA defines friable as a material that when dry, may be crumbled, pulverized, or reduced to powder by hand pressure. A homogenous area is defined by

OSHA as an area of surfacing, thermal system insulation (TSI) or miscellaneous material that is uniform in color and texture. Surfacing materials are most commonly found in sprayed-on, troweled-on or otherwise applied to surfaces, such as acoustical plaster on ceilings and fireproofing materials on structural members. TSI refers to materials applied to pipes, fittings, boilers, ductwork, or other components to prevent heat loss or gain, or condensation. Any material that does not fall under the surfacing or TSI category, such as floor tile, drywall, and acoustical ceiling tile are placed into the miscellaneous materials category.

Following the completion of the visual inspection, Red Cedar staff identified the following materials as suspect ACBM:

• 12”x12” Vinyl Floor Tile

• 2’x4’ Ceiling Tile

• Asphalt Shingle

• Window Glazing

• Plaster

Red Cedar staff collected seventeen samples of suspect ACBM separated into five distinct homogenous groups for laboratory analysis. Samples were collected and submitted to APEX Research Inc.

Laboratories (APEX) (Accreditation Number 102118-0) for laboratory analysis. Analysis was completed utilizing polarized light microscopy (PLM) which is the Environmental Protection Agency (EPA) approved method for analysis of bulk materials for asbestos. PLM analysis completed pursuant to method (EPA 600/M4-82-020) identifies asbestos fiber bundles by the visual properties displayed when the sample is treated with various dispersion staining liquids. The laboratory report completed following the sample analysis indicates if asbestos is present, and at what percentage along with a description and percentage of other fibrous and non-fibrous materials and sample color. Chain-of-custody documentation was followed from sample collection through shipping and receiving of the samples at the designated laboratory. The documentation assures that samples will meet the quality assurance/quality control measures defined by AHERA. The laboratory analytical report prepared by APEX for the seventeen samples is included as Attachment A.

Hazardous Materials Inspection

On September 10, 2025, the Subject Property was also inspected for the presence of hazardous materials which include but are not limited to polychlorinated biphenyls (PCBs) and potential mercury containing equipment and any items or containers that may contain or be classified as a hazardous or regulated material. Each material, if identified, was documented along with the approximate location. Any materials identified as hazardous are included in Table 1.

INSPECTION RESULTS AND RECOMMENDATIONS

During the completion of the asbestos inspection, seventeen samples of suspect ACM were collected and are documented in Table 2 along with the Red Cedar sample number, description, friability, material type, ACM classification, sample location, material quantity and laboratory analytical results. A Site Diagram was prepared which provides the general building layout and sample locations and is included as

Attachment B.

ACM, as defined by the USEPA NESHAP is “any material containing more than 1 percent asbestos as determined using the method specified in appendix E, subpart E, 40 CFR part 763 Section 1, Polarized

Light Microscopy”.

Friable ACM is defined by NESHAP as any material containing more than 1 percent asbestos that, when dry, can be crumbled, pulverized, or reduced to powder by hand pressure. Friable ACM is a concern due to the ease of unintentionally disturbing the ACM which may result in “visible emissions” which is known as a Fiber Release Episode.

Non-friable asbestos-containing material is defined as “material containing more than 1 percent asbestos that, when dry, cannot be crumbled, pulverized, or reduced to powder by hand pressure. Non-friable

ACMs are separated into Category I and Category II ACM. Category I ACM is any asbestos containing packing’s, gaskets, resilient floor coverings (vinyl floor tile and linoleum are examples of these) and asphalt roofing products. Category II ACM is stated by NESHAP as any material excluding Category I non-friable ACM such as drywall, plaster or fiberboard insulation.

Presumed Asbestos Containing Material

Presumed Asbestos Containing Materials (PACM) are suspect surfacing, TSI and miscellaneous materials found in buildings constructed prior to 1980 which are classified as and due to the age of the structure, are assumed to be ACM and do not require sample collection and analysis. OSHA dictates that PACM may be “rebutted” following a complete inspection pursuant to AHERA protocol.

The HVAC Duct Wrap located in the Building and the Cementatious “Transite” Siding on the Building was classified as PACM due to the age of the structure and samples were not collected.

Table 3 lists the location, material description, friability, condition, material type (surfacing, thermal or miscellaneous) and approximate quantity of all PACM documented at the Subject Property.

Table 4 provides a summary of all ACM documented at the Subject Property which includes the material location, description, and approximate quantity.

Friable ACM’s

Window glazing samples collected from windows in the interior of the Building were found to contain up to 2% asbestos following analysis. The assessment to quantify the extent of this material identified sixteen windows at the following locations that would fall into the same homogenous group. The locations of the windows are listed below:

• Living 1 (4 windows 20” wide x 53” tall)

• Kitchen 1 (1 window 36” wide x 53” tall)

• Living 2 (4 windows 36” wide x 30” tall)

• Kitchen 2 (1 window 36” wide x 53” tall)

• 2nd Fl. Living 3 (2 windows 20” wide x 53” tall)

• 2nd Fl. Closet (1 window 24” wide x 36” tall)

• 2nd Fl. Living 4 (2 windows 20” wide x 53” tall)

• 2nd Fl. Bedroom 4 (1 window 24” wide x 36” tall)

Duct Wrap identified in the building in conjunction with the forced air heating system is classified as friable ACM. The visual assessment to quantify the extent of this material identified HVAC Duct Wrap at the following locations within the basement, first and second floors:

• Interior (HVAC Wrapped Ductwork, 4 Runs 25 sq. ft. each) (100 sq. ft.)

Category I ACM

No Category I ACM was identified during the completion of this inspection.

Category II ACM

The cementatious “Transite” siding located on the exterior of the Building was classified as PACM and no samples were collected. The visual assessment to quantify the extent of this material identified 3,356

sq. ft. of cementatious (Transite) siding on the Building.

RECOMMENDATIONS

Asbestos Containing Materials

HVAC material identified in the Building system and listed below is classified as friable ACM and should be removed prior to any renovation/demolition activities.

• Interior (HVAC Wrapped Ductwork, 4 Runs 25 sq. ft. each) (100 sq. ft.)

Friable asbestos containing window glazing was identified on sixteen windows throughout the Building.

The locations of these windows that should be abated prior to demolition/renovation activities are listed below:

• Living 1 (4 windows 20” wide x 53” tall)

• Kitchen 1 (1 window 36” wide x 53” tall)

• Living 2 (4 windows 36” wide x 30” tall)

• Kitchen 2 (1 window 36” wide x 53” tall)

• 2nd Fl. Living 3 (2 windows 20” wide x 53” tall)

• 2nd Fl. Closet (1 window 24” wide x 36” tall)

• 2nd Fl. Living 4 (2 windows 20” wide x 53” tall)

• 2nd Fl. Bedroom 4 (1 window 24” wide x 36” tall)

Please note: Other different sized windows are located throughout the Building but these windows were assessed and found to be constructed either without window glazing or were sampled and found to not contain asbestos and therefore are not required to be removed.

Transite siding was identified on the exterior of the Building and must be abated prior to completion of any demolition activities at the Subject Property. In demolition, all cementatious ACM must be removed prior to demolition due to the likelihood of becoming regulated due to the demolition process.

Please note: The location of samples obtained during this inspection were in a random fashion and areas that were not identified during this inspection may be damaged or have become damaged since the inspection was completed. If Category I or Category II friable materials are discovered prior to or during the demolition/renovation process, these materials must be abated prior to commencement of any demolition/renovation activities at the Subject Property.

Hazardous Materials

Hazardous Materials identified at the Subject Property and documented in Table 1 which require proper removal and disposal consist of the following items:

• Fire Extinguisher (1)

• Automobile Tires (2)

REGULATORY REQUIREMENTS

A Notification of intent to Renovate/Demolish form must be filed with the Michigan Department of

Environmental Quality- Air Quality Division at least 10 working days prior to any renovation or demolition activities at a site.

The Notification of Intent to Renovate/Demolish form must also be completed and submitted to the

MIOSHA-Asbestos Program whenever demolition, encapsulation and/or renovation activities at a site involving greater than ten lineal feet and/or fifteen square feet of ACM will be completed.

Regulated asbestos containing materials per NESHAP (40 CFR Part 61) which falls into any of the following categories are ACM’s that must be removed prior to any renovation/demolition activities at the

Subject Property.

• Friable asbestos material.

• Category I non-friable ACM that has become friable.

• Category I non-friable ACM that will be or has been subjected to sanding, grinding, cutting, or abrading.

• Category II non-friable ACM that has a high probability of becoming or has become crumbled, pulverized, or reduced to powder by the forces expected to act on the material in the course of renovation or demolition operations.

Asbestos abatement should only be performed by a certified asbestos abatement contractor licensed to complete abatement work. The contractor must also follow the standards and requirements set forth per the OSHA Asbestos Standards for Construction (29 CFR 1926.1101) and the USEPA NESHAP (40 CFR

Part 61).

Additional information regarding the OSHA Asbestos Standards for Construction (29 CFR 1926.1101) and the USEPA NESHAP (40 CFR Part 61) can be obtained by contacting the associated agency below.

NESHAP Asbestos Program MIOSHA-CSHD-Asbestos Program

Department of Environmental Quality State of Michigan

Phone: 517-284-6777 Phone: 517-284-7680

Email: asbestos@michigan.gov

DISCLAIMER

Red Cedar Consulting performed destructive testing methods in an attempt to access and inspect all areas of the Building. Unfortunately, due to the age of construction along with multiple additions/renovations that may have been completed on the Building, additional inspections may be required if suspect ACM material not documented within this report is encountered during renovation/demolition activities.

This report was prepared at the request and for exclusive use by the City of Jackson and may not be reproduced or sold without written permission from Red Cedar Consulting.

We appreciate the opportunity to provide the requested services. Please contact us at (888) 449-4566 with any questions or concerns.

Sincerely, Red Cedar Consulting

Aaron Paquet

Michigan/EPA Certified Asbestos Building Inspector

(A30955)

©2025 Red Cedar Consulting, LLC.

Attachment A

APEX Research Laboratory Analytical Results

Certificate of Laboratory Analysis Test Method, Polarized Light Microscopy (PLM)

Report To: ARI Report # 25-119619 Mr. Aaron Paquet Date Collected: 09/10/25 Red Cedar Consulting Date Received: 09/11/25 P.O. Box 13216 Date Analyzed: 09/16/25 Lansing, MI 48901 Date Reported: 09/18/25

Sample Information Asbestos Type/Percent Non-Asbestos Material

Lab ID #: 119619 - 01 Asbestos Present: NO Other - 100%

Cust. #: GA-HM-01A No Asbestos Observed Material: 12x12 Green 4" Squared Vinyl Floor Tile Location:

Appearance: grey,nonfibrous,homogenous Layer: 1 of 5

Lab ID #: 119619 - 01a Asbestos Present: NO Other - 100%

Material: Glue Location:

Appearance: clear,nonfibrous,homogenous Layer: 2 of 5

Lab ID #: 119619 - 01b Asbestos Present: NO Other - 100%

Material: Beige Flooring Location:

Appearance: beige,nonfibrous,nonhomogenous Layer: 3 of 5

For Layered Samples, each component will be analyzed and reported separately.

Robert T. Letarte Jr., Laboratory Director

Test Method EPA 40 CFR - Part 763 and/or EPA 600/R-93/116 was used to analyze the above samples. Matrix interference and/or resolution limits may yield false/negative results in certain circumstances. Suspect floor tiles containing <1% should be tested with SEM or TEM. This certificate of analysis relates only to the samples as submitted and to insure the integrity of the results, may only be reproduced in full. This certificate must not be used by the customer to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the Federal Government. Liability limited to cost of analysis.

Project: 1004 Greenwood Ave.

NVLAP Lab Code 102118-0

APEX Research Inc., 7717 Kensington Ct., Brighton, MI 48116

(734) 449-9990, Fax (734) 449-9991 Page 1 of 12

Red Cedar Consulting Date Received: 09/11/25

Lab ID #: 119619 - 01c Asbestos Present: NO Cellulose - 40%

Cust. #: GA-HM-01A No Asbestos Observed Other - 60% Material: Brown Sheet Floor/Felt Location:

Appearance: brown,fibrous,nonhomogenous Layer: 4 of 5

Lab ID #: 119619 - 01d Asbestos Present: NO Cellulose - 40% Cust. #: GA-HM-01A No Asbestos Observed Other - 60% Material: Grey Sheet Floor/Felt Location:

Appearance: grey,fibrous,nonhomogenous Layer: 5 of 5

Lab ID #: 119619 - 02 Asbestos Present: NO Other - 100% Cust. #: GA-HM-01B No Asbestos Observed Material: 12x12 Green 4" Squared Vinyl Floor Tile Location:

Layer: 1 of 5

Test Method EPA 40 CFR - Part 763 and/or EPA 600/R-93/116 was used to analyze the above samples. Matrix interference and/or resolution limits may yield false/negative results in certain circumstances. Suspect floor tiles containing <1% should be tested with SEM or TEM. This certificate of analysis relates only to the samples as submitted and to insure the integrity of the results, may only be reproduced in full. This certificate must not be used by the customer to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the Federal

(734) 449-9990, Fax (734) 449-9991 Page 2 of 12

Red Cedar Consulting Date Received: 09/11/25

Lab ID #: 119619 - 02a Asbestos Present: NO Other - 100%

Material: Glue Location:

Appearance: clear,nonfibrous,homogenous Layer: 2 of 5

Lab ID #: 119619 - 02b Asbestos Present: NO Other - 100%

Material: Beige Flooring Location:

Appearance: beige,nonfibrous,nonhomogenous Layer: 3 of 5

Lab ID #: 119619 - 02c Asbestos Present: NO Cellulose - 40% Cust. #: GA-HM-01B No Asbestos Observed Other - 60% Material: Brown Sheet Floor/Felt Location:

Appearance: brown,fibrous,nonhomogenous Layer: 4 of 5

Test Method EPA 40 CFR - Part 763 and/or EPA 600/R-93/116 was used to analyze the above samples. Matrix interference and/or resolution limits may yield false/negative results in certain circumstances. Suspect floor tiles containing <1% should be tested with SEM or TEM. This certificate of analysis relates only to the samples as submitted and to insure the integrity of the results, may only be reproduced in full. This certificate must not be used by the customer to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the Federal

(734) 449-9990, Fax (734) 449-9991 Page 3 of 12

Red Cedar Consulting Date Received: 09/11/25

Lab ID #: 119619 - 02d Asbestos Present: NO Cellulose - 40%

Cust. #: GA-HM-01B No Asbestos Observed Other - 60% Material: Grey Sheet Floor/Felt Location:

Appearance: grey,fibrous,nonhomogenous Layer: 5 of 5

Lab ID #: 119619 - 03 Asbestos Present: NO Cellulose - 40% Cust. #: GA-HM-02A No Asbestos Observed Mineral Wool - 30% Material: 2x4 White Ceiling Tile w/ Pinholes & Fissures Other - 30% Location:

Appearance: beige,fibrous,homogenous Layer: 1 of 1

Lab ID #: 119619 - 04 Asbestos Present: NO Cellulose - 40% Cust. #: GA-HM-02B No Asbestos Observed Mineral Wool - 30% Material: 2x4 White Ceiling Tile w/ Pinholes & Fissures Other - 30% Location:

Test Method EPA 40 CFR - Part 763 and/or EPA 600/R-93/116 was used to analyze the above samples. Matrix interference and/or resolution limits may yield false/negative results in certain circumstances. Suspect floor tiles containing <1% should be tested with SEM or TEM. This certificate of analysis relates only to the samples as submitted and to insure the integrity of the results, may only be reproduced in full. This certificate must not be used by the customer to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the Federal

(734) 449-9990, Fax (734) 449-9991 Page 4 of 12

Red Cedar Consulting Date Received: 09/11/25

Lab ID #: 119619 - 05 Asbestos Present: NO Fiberglass - 30%

Cust. #: GA-HM-03A No Asbestos Observed Other - 70% Material: Black Roofing Shingle Location:

Appearance: black,fibrous,nonhomogenous Layer: 1 of 3

Lab ID #: 119619 - 05a Asbestos Present: NO Fiberglass - 30%

Material: Shingle Location:

Layer: 2 of 3

Lab ID #: 119619 - 05b Asbestos Present: NO Fiberglass - 30%

Material: Felt Location:

Layer: 3 of 3

Test Method EPA 40 CFR - Part 763 and/or EPA 600/R-93/116 was used to analyze the above samples. Matrix interference and/or resolution limits may yield false/negative results in certain circumstances. Suspect floor tiles containing <1% should be tested with SEM or TEM. This certificate of analysis relates only to the samples as submitted and to insure the integrity of the results, may only be reproduced in full. This certificate must not be used by the customer to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the Federal

(734) 449-9990, Fax (734) 449-9991 Page 5 of 12

Red Cedar Consulting Date Received: 09/11/25

Lab ID #: 119619 - 06 Asbestos Present: NO Fiberglass - 30%

Cust. #: GA-HM-03B No Asbestos Observed Other - 70% Material: Black Roofing Shingle Location:

Layer: 1 of 3

Lab ID #: 119619 - 06a Asbestos Present: NO Fiberglass - 30%

Material: Shingle Location:

Layer: 2 of 3

Lab ID #: 119619 - 06b Asbestos Present: NO Fiberglass - 30%

Material: Felt Location:

Appearance: black,fibrous,homogenous Layer: 3 of 3

Test Method EPA 40 CFR - Part 763 and/or EPA 600/R-93/116 was used to analyze the above samples. Matrix interference and/or resolution limits may yield false/negative results in certain circumstances. Suspect floor tiles containing <1% should be tested with SEM or TEM. This certificate of analysis relates only to the samples as submitted and to insure the integrity of the results, may only be reproduced in full. This certificate must not be used by the customer to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the Federal

(734) 449-9990, Fax (734) 449-9991 Page 6 of 12

Red Cedar Consulting Date Received: 09/11/25

Lab ID #: 119619 - 07 Asbestos Present: YES Wollastonite - 2%

Cust. #: GA-HM-04A Chrysotile - 2% Other - 96% Material: Window Glazing Location:

Lab ID #: 119619 - 08 Asbestos Present:

Cust. #: GA-HM-04B Material: Window Glazing Location: NOT ANALYZED Appearance:

Lab ID #: 119619 - 09 Asbestos Present:

Cust. #: GA-HM-04C Material: Window Glazing Location: NOT ANALYZED

Test Method EPA 40 CFR - Part 763 and/or EPA 600/R-93/116 was used to analyze the above samples. Matrix interference and/or resolution limits may yield false/negative results in certain circumstances. Suspect floor tiles containing <1% should be tested with SEM or TEM. This certificate of analysis relates only to the samples as submitted and to insure the integrity of the results, may only be reproduced in full. This certificate must not be used by the customer to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the Federal

(734) 449-9990, Fax (734) 449-9991 Page 7 of 12

Red Cedar Consulting Date Received: 09/11/25

Lab ID #: 119619 - 10 Asbestos Present:

Cust. #: GA-HM-04D Material: Window Glazing Location: NOT ANALYZED

Lab ID #: 119619 - 11 Asbestos Present: NO Other - 100% Cust. #: GA-HS-01A No Asbestos Observed Material: Plaster Finish Coat Location:

Appearance: white,nonfibrous,homogenous Layer: 1 of 2

Lab ID #: 119619 - 11a Asbestos Present: NO Mica -10% Cust. #: GA-HS-01A No Asbestos Observed Other - 90% Material: Plaster Base Coat Location:

Layer: 2 of 2

Test Method EPA 40 CFR - Part 763 and/or EPA 600/R-93/116 was used to analyze the above samples. Matrix interference and/or resolution limits may yield false/negative results in certain circumstances. Suspect floor tiles containing <1% should be tested with SEM or TEM. This certificate of analysis relates only to the samples as submitted and to insure the integrity of the results, may only be reproduced in full. This certificate must not be used by the customer to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the Federal

(734) 449-9990, Fax (734) 449-9991 Page 8 of 12

Red Cedar Consulting Date Received: 09/11/25

Lab ID #: 119619 - 12 Asbestos Present: NO Other - 100%

Cust. #: GA-HS-01B No Asbestos Observed Material: Plaster Finish Coat Location:

Lab ID #: 119619 - 12a Asbestos Present: NO Mica -10% Cust. #: GA-HS-01B No Asbestos Observed Other - 90% Material: Plaster Base Coat Location:

Lab ID #: 119619 - 13 Asbestos Present: NO Other - 100% Cust. #: GA-HS-01C No Asbestos Observed Material: Plaster Finish Coat Location:

Test Method EPA 40 CFR - Part 763 and/or EPA 600/R-93/116 was used to analyze the above samples. Matrix interference and/or resolution limits may yield false/negative results in certain circumstances. Suspect floor tiles containing <1% should be tested with SEM or TEM. This certificate of analysis relates only to the samples as submitted and to insure the integrity of the results, may only be reproduced in full. This certificate must not be used by the customer to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the Federal

(734) 449-9990, Fax (734) 449-9991 Page 9 of 12

Red Cedar Consulting Date Received: 09/11/25

Lab ID #: 119619 - 13a Asbestos Present: NO Cellulose - 1%

Cust. #: GA-HS-01C No Asbestos Observed Mica -10% Material: Plaster Base Coat Other - 89% Location:

Lab ID #: 119619 - 14 Asbestos Present: NO Other - 100% Cust. #: GA-HS-01D No Asbestos Observed Material: Plaster Finish Coat Location:

Lab ID #: 119619 - 14a Asbestos Present: NO Mica -10% Cust. #: GA-HS-01D No Asbestos Observed Other - 90% Material: Plaster Base Coat Location:

Test Method EPA 40 CFR - Part 763 and/or EPA 600/R-93/116 was used to analyze the above samples. Matrix interference and/or resolution limits may yield false/negative results in certain circumstances. Suspect floor tiles containing <1% should be tested with SEM or TEM. This certificate of analysis relates only to the samples as submitted and to insure the integrity of the results, may only be reproduced in full. This certificate must not be used by the customer to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the Federal

(734) 449-9990, Fax (734) 449-9991 Page 10 of 12

Red Cedar Consulting Date Received: 09/11/25

Lab ID #: 119619 - 15 Asbestos Present: NO Other - 100%

Cust. #: GA-HS-01E No Asbestos Observed Material: Plaster Finish Coat Location:

Lab ID #: 119619 - 15a Asbestos Present: NO Cellulose - 1% Cust. #: GA-HS-01E No Asbestos Observed Mica -10% Material: Plaster Base Coat Other - 89% Location:

Lab ID #: 119619 - 16 Asbestos Present: NO Other - 100% Cust. #: GA-HS-01F No Asbestos Observed Material: Plaster Finish Coat Location:

Test Method EPA 40 CFR - Part 763 and/or EPA 600/R-93/116 was used to analyze the above samples. Matrix interference and/or resolution limits may yield false/negative results in certain circumstances. Suspect floor tiles containing <1% should be tested with SEM or TEM. This certificate of analysis relates only to the samples as submitted and to insure the integrity of the results, may only be reproduced in full. This certificate must not be used by the customer to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the Federal

(734) 449-9990, Fax (734) 449-9991 Page 11 of 12

Red Cedar Consulting Date Received: 09/11/25

Lab ID #: 119619 - 16a Asbestos Present: NO Cellulose - 1%

Cust. #: GA-HS-01F No Asbestos Observed Mica -10% Material: Plaster Base Coat Other - 89% Location:

Lab ID #: 119619 - 17 Asbestos Present: NO Other - 100% Cust. #: GA-HS-01G No Asbestos Observed Material: Plaster Finish Coat Location:

Lab ID #: 119619 - 17a Asbestos Present: NO Mica -10% Cust. #: GA-HS-01G No Asbestos Observed Other - 90% Material: Plaster Base Coat Location:

Test Method EPA 40 CFR - Part 763 and/or EPA 600/R-93/116 was used to analyze the above samples. Matrix interference and/or resolution limits may yield false/negative results in certain circumstances. Suspect floor tiles containing <1% should be tested with SEM or TEM. This certificate of analysis relates only to the samples as submitted and to insure the integrity of the results, may only be reproduced in full. This certificate must not be used by the customer to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the Federal

(734) 449-9990, Fax (734) 449-9991 Page 12 of 12

Attachment B Figure 1 Site Diagram

Figure 1a Site Diagram

Note: Figure created by Red Cedar Consulting Asbestos Sample Locations 1004 Greenwood Ave.

-Not To Scale- Jackson, MI

Figure 1b Site Diagram

Note: Figure created by Red Cedar Consulting Asbestos Sample Locations 1004 Greenwood Ave.

-Not To Scale- Jackson, MI

Tables

Table 1 - Summary of Hazardous Materials, 1004 Greenwood Ave. Jackson, Michigan

Hazardous Materials Description and Location

Location Material Description Quantity

2nd Floor Fire Extinguisher 1

Exterior Automobile Tires 2

Table 2 - Summary of Sample Descriptions and Asbestos Laboratory Results, 1004 Greenwood Ave. Jackson, Michigan

Sample

Number Sample Description Friable

Material

Type

Classification

% Asbestos

Laboratory

Result

Sample Location Approx. Material

Quantity

GA-HM-01A

12”x12” Green 4” Squared Vinyl

Floor Tile/Multilayer No M Category I

ND/ND/ND/

ND/ND

Kitchen 1 NA

GA-HM-01B

12”x12” Green 4” Squared Vinyl

Floor Tile/Multilayer No M Category I

ND/ND/ND/

ND/ND

Bathroom 3 NA

GA-HM-02A

2’x4’ White Ceiling Tile with

Pinholes and Fissures Yes M Category II ND Bathroom 1 NA

GA-HM-02B

2’x4’ White Ceiling Tile with

Pinholes and Fissures Yes M Category II ND Bathroom 1 NA

GA-HM-03A Black Roofing Shingle No M Category I ND/ND/ND Building SW Exterior NA

GA-HM-03B Black Roofing Shingle No M Category I ND/ND/ND Building N Exterior NA

GA-HM-04A Window Glazing Yes M Category II 2%CH Bedroom 2 16 Windows

GA-HM-04B Window Glazing Yes M Category II NA Living 2 NA

GA-HM-04C Window Glazing Yes M Category II NA 2nd Fl. Living 3 NA

GA-HM-04D Window Glazing Yes M Category II NA 2nd Fl. Bedroom 4 NA

GA-HS-01A Plaster No S Category II ND/ND Front Entry NA

GA-HS-01B Plaster No S Category II ND/ND Living 2 NA

GA-HS-01C Plaster No S Category II ND/ND Kitchen 2 NA

GA-HS-01D Plaster No S Category II ND/ND Living 1 NA

GA-HS-01E Plaster No S Category II ND/ND Living 3 NA

GA-HS-01F Plaster No S Category II ND/ND Kitchen 3 NA

GA-HS-01G Plaster No S Category II ND/ND Living 4 NA

Notes:

Material Types Abbreviations

M = Miscellaneous building material NQ = Not quantified

TSI = Thermal System Insulation NA = Not Analyzed

S = Surfacing Material ND = Not detected. Laboratory result is less than 1 % asbestos

PC = Point Count Analysis lin. ft. = linear feet

CH = Chrysotile Asbestos sq. ft. = square feet

Asbestos Containing Material (ACM) is defined as any material containing more than 1 percent asbestos as determined utilizing Polarized Light Microscopy.

Table 3 - Summary of Presumed Asbestos Containing Materials, 1004 Greenwood Ave. Jackson, Michigan

Asbestos Containing Material Description and Location

Location Material Description Friable Condition

Type Approx. Quantity

Building Exterior Transite Siding No Fair M 3,356 sq. ft.

Basement (4 Chases HVAC Wrapped Ductwork, 25 sq. ft. each)

HVAC Duct Wrap Yes Fair TSI 100 sq. ft.

Material Types Abbreviations

M = Miscellaneous building material lin. ft. = linear feet

TSI = Thermal System Insulation sq. ft. = square feet

S = Surfacing Material

Table 4 - Summary of All Asbestos Containing Materials, 1004 Greenwood Ave. Jackson, Michigan

Interior - Asbestos Containing Materials

Location Material Description Friable Approx. Quantity

Interior Chases (HVAC Wrapped Ductwork, 4 Runs 25 sq. ft.

each) HVAC Duct Wrap Yes 100 sq. ft.

Total 100 sq. ft.

Interior - Asbestos Containing Materials

Living 1 (4 windows 20” wide x 53” tall) Glazing Yes 4 Windows

Kitchen 1 (1 window 36” wide x 53” tall) Glazing Yes 1 Window

Living 2 (4 windows 36” wide x 30” tall) Glazing Yes 4 Windows

Kitchen 2 (1 window 36” wide x 53” tall) Glazing Yes 1 Window

2nd Fl. Living 3 (2 windows 20” wide x 53” tall) Glazing Yes 2 Windows

2nd Fl. Closet (1 window 24” wide x 36” tall) Glazing Yes 1 Window

2nd Fl. Living 4 (2 windows 20” wide x 53” tall) Glazing Yes 2 Windows

2nd Fl. Bedroom 4 (1 window 24” wide x 36” tall) Glazing Yes 1 Window

Total 16 Windows

Exterior - Asbestos Containing Materials

Building Exterior Transite Siding No 3,356 sq. ft.

Total 3,356 sq. ft.

Abbreviations lin. ft. = linear feet

sq. ft. = square feet

Shaded/Bolded = Friable ACM and any Category I and Category II non-friable ACM that has a high probability of becoming crumbled, pulverized, or reduced to powder by the demolition or renovation activities that must be properly abated prior to commencement of any demolition/renovation activities.

Demolition/renovation activities completed with intact Category I non-friable ACM are regulated by OSHA and must be completed following the OSHA Asbestos Standards for

Construction (29 CFR 1926.1101) which limits employee exposure to asbestos.

Table 4 - Summary of All Asbestos Containing Materials, 1004 Greenwood Ave. Jackson, Michigan

Please note that a Negative Pressure Enclosure must be utilized during abatement when Site Conditions Warrant. Examples of these conditions include the abatement of Plaster and Vermiculite insulation, HVAC Duct Wrap in Poor Condition, and Air-O-Cell/Mag Pipe Wrap. Conditions outside of these should be assessed on a case by case basis during the Asbestos Abatement Contractors site walk and Work Plan Preparation.

1004 Greenwood- Demolition Special Conditions.docx

To: Kari Kerstetter, Purchasing Department

From: Neighborhood & Economic Operations Dept.

Date: 08-13-25

Re: Please solicit bids for demolition of the following property as soon as possible.

Property Address: 1004 Greenwood

Parcel Number: 4-121500000

Sq Ft: 1862 sq. ft. (house)

Special Conditions to include:

1) Hazardous materials must be abated in accordance with MIOSHA and DEQ regulations and the attached Pre-Demolition Compliance Survey assessment.

2) Compact all clean backfill material with a hoe-pack or vibrating roller compactor.

3) Remove _ _1_ curb(s) cut(s) and entry approach(s). (27 lineal feet)

4) Install _ __36_ lineal feet of curb and gutter. If road is in disrepair will need to be cut street and have forms installed to form front gutter pan and then have road repaired with hot patch asphalt upon completion of concrete work.

5) Remove and replace _ 120 lineal feet _of cracked, heaved and broken public sidewalks.

6) See enclosed water and sewer service records for approximate location and any special instructions for shared services. If no service card is provided it is the contractor’s responsibility to insure that neighboring water and sewer services are operational at the conclusion of the demolition.

1) Trees/shrubs: Remove all vegetation from property including all trees, brush, weeds, stumps, and all vegetation from site. Plant 2 – 2 ½” caliper Japanese Lilac trees evenly spaced to ROW area along Greenwood St.

2) Miscellaneous: Remove asphalt to NW, remove all fencing along S property line and remove all vegetation along S line to allow for regrade. Remove split rail fencing to E. Regrade full site to smooth all grades and to blend with all surrounding elevations.