100 Percent 528A7-23-105_08-22-2023.pdf

PDF 2 MB Posted

Attached to
Z1DA--528A7-23-105 REPLACE ROOF 43 Federal contract opportunity
Solicitation number
36C24223B0045
Issued by
Department of Veterans Affairs Veterans Health Administration Veterans Integrated Service Network 2

About this file

This solicitation is for a roof replacement project at the Syracuse VA Medical Center in New York. The Department of Veterans Affairs is seeking to replace the roof on Building 1, including removal of the existing roof system down to the concrete deck and installation of new tapered insulation, a 12-inch coverboard, fully adhered EPDM membrane, flashings, and accessories. The project number is 528A7-23-105 and is identified as Replace Roof 43. The contractor must follow infection control procedures and coordinate work with facility staff to ensure continued emergency patient isolation capability. The response due date is not provided.

View the file

Other files for this federal contract opportunity

Other files attached to Z1DA--528A7-23-105 REPLACE ROOF 43, newest first.
File Type Posted
Roof 43 - Options.pdf PDF
36C24223B0045 0001.docx DOCX document
852.219-77 VA Notice of Limitations on Subcontracting.docx DOCX document
FAR 52.225-2 Buy American Certification.pdf PDF
36C24223B0045_1.docx DOCX document
(P09) Final SOW.docx DOCX document
528A7-23-105_Replace Roof 43_Combined_SPECS_100 Percent.pdf PDF

On GovTribe

Work with this file on GovTribe

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

DRAWINGS INDEX

SHEET NO. DRAWING TITLE

GENERAL

1. GI-001 COVER SHEET

2. GC-101 INFECTION CONTROL (ICRA) PLAN

ARCHITECTURAL

3. A-001 ARCHITECTURAL ABBREVIATIONS, SYMBOLS & DETAILS

4. AD-101 ARCHITECTURAL ROOF DEMOLITION PLAN

5. A-101 ARCHITECTURAL ROOF PLAN & DETAILS

6. A-501 ARCHITECTURAL ROOF DETAILS AND SCHEDULES

DEPARTMENT OF VETERANS AFFAIRS PROJECT NO. 528A7-20-752

VA MEDICAL CENTER

BUILDING NO. 1

800 IRVING AVENUE

SYRACUSE, NEW YORK, 13210

SYRACUSE VAMC

REPLACE ROOF 43

KEY PLAN

SCALE: NONE

N on e ei gh th in ch o ne fo ot

B

A

C

D

E

F th re e in ch es o ne fo ot 6"

6" on e an d on e ha lf in ch es o ne fo ot on e in ch o ne fo ot

6" 6" th re e qu ar te rs in ch o ne fo ot on e ha lf in ch o ne fo ot th re e ei gh th s in ch o ne fo ot on e qu ar te r i nc h on e fo ot

VA FORM 08-6231

1 2 3 4 5 6 87 9

97 8654321

DRAWING TITLE PROJECT TITLE

LOCATION

DATE CHECKED DRAWN

DRAWING NUMBER

BUILDING NUMBER

PROJECT NUMBER

REVISION DATE

SYRACUSE

VA MEDICAL

CENTER

ENGINEERING

DEPARTMENT

800 IRVING AVE. SYRACUSE, NY 13210

03/31/2023

GENERAL PROJECT INFORMATION

100% SPRINKLERED

DWG.

U.S. Department of Veterans Affairs

B

A

C

D

E

F

528A7-23-105REPLACE ROOF 43

100% DRAWING DOC 01 OF 06

GI-001

KAWDW

COVER SHEET

AREA OF WORK

EMERGENCY DEPARTMENT REPLACE ROOF 43

PROJECT NUMBER: 528A7-23-105

PROJECT ADDRESS: 800 IRVING AVE SYRACUSE, NY 13210

STATEMENT OF WORK

THE GENERAL CONTRACTOR SHALL PROVIDE LABOR, SUPERVISION, MATERIALS, AND EQUIPMENT PER THE CONSTRUCTION DOCUMENTS FOR PROJECT 528A7-23-105, REPLACE ROOF 43. THE NEW ROOF WILL HAVE TAPERED INSULATION AND AN EPDM ROOFING SYSTEM, SLOPING TO THE NEWLY INSTALLED ROOF DRAINS, FLASHING AROUND EXISTING EQUIPMENT CURBS, TO INCLUDE ALL REQUIRED BLOCKING, CANTS, ASSOCIATED METAL WORK AND SPECIALTIES. THE COMPLETED ROOF REPLACEMENT WILL BE IN ACCORDANCE WITH THE MOST

CURRENT CODES AND VA DESIGN GUIDELINES.

THE SCOPE OF WORK INCLUDES DEMOLITION OF THE EXISTING ROOFING ASSEMBLIES DOWN TO THE CONCRETE DECK. COORDINATION WITH THE VA COR AND EMERGENCY DEPARTMENT STAFF WILL BE REQUIRED TO ENSURE UNINTERRUPTED EMERGENCY PATIENT ISOLATION CAPABILITY. REPLACEMENT WORK IS TO INCLUDE INSTALLATION OF NEW EPDM ROOFING SYSTEM, FLASHING AROUND EXISTING EQUIPMENT CURBS, TAPERED INSULATED ROOFING SYSTEM TO INCLUDE ALL REQUIRED BLOCKING, CANTS, ASSOCIATED METAL WORK AND

SPECIALTIES.

THE INTENT IS FOR CONSTRUCTION IN THE SUMMER OF 2023.

EF-07

EF-08

MAIN ENTRANCE

ROOF 2333 SF

170 LF OUTSIDE

MAIN ENTRANCE

ROOF 347 SF

MAIN ENTRANCE

ROOF 567 SF

GENERAL NOTES:

1. CONTRACTOR MUST FOLLOW ALL INFECTION CONTROL PROCEDURES DEFINED IN

PROJECT SPECIFICATIONS.

2. CONTRACTOR IS TO COORDINATE ALL WORK AND SCHEDULES WITH VAMC COR. SEE

SHEET AD-101 FOR ADDITIONAL INFORMATION.

3. NO CONTRACTOR STORAGE IS ACCEPTABLE IN CORRIDORS. ALL MATERIALS MUST BE

CONTAINED IN THE ACTIVE WORK AREA, OR ASSIGNED AREAS ACCEPTABLE TO THE

VAMC COR.

4. REFER TO SPECIFICATION SECTION 01 74 19 FOR CONSTRUCTION WASTE MANAGEMENT.

5. PROVIDE TEMPORARY CONSTRUCTION SIGNAGE AT INTERIOR AND EXTERIOR OF

PROJECT WORK AREA. COORDINATE WITH VAMC COR ON REQUIREMENTS AND

LOCATIONS.

6. ANY WORK TO BE PERFORMED OUTSIDE OF THE CONSTRUCTION BARRIER SHALL BE

COORDINATED WITH THE VAMC COR.

7. ALL CONTRACTOR EQUIPMENT / CARTS, ETC. MUST BE WIPED DOWN PRIOR TO ENTRY

OR EXIT. ONCE IN, CARTS SHOULD BE WIPED DOWN PRIOR TO RELOCATION TO NEW

WORK AREA. THIS SHALL INCLUDE ALL EQUIPMENT / CART WHEELS.

8. PATCH ALL FINISHES DAMAGED BY TEMPORARY PARTITION INSTALLATION AND

REMOVAL TO MATCH EXISTING FINISHES.

9. THE CONTRACTOR SHALL NOT TRANSFER ANY CART THROUGH THE HOSPITAL THAT

DOES NOT HAVE A CLEANED COVER.

10. THE CONTRACTOR SHALL CLEAN THE SERVICE ELEVATORS IF CONSTRUCTION

MATERIAL IS TRACKED ON TO IT.

DRAWING LEGEND:

CONSTRUCTION WORK BOUNDARY

ROOF OUTLINE FROM ABOVE

on e ei gh th in ch o ne fo ot

B

A

C

D

E

F th re e in ch es o ne fo ot 6"

6" on e an d on e ha lf in ch es o ne fo ot on e in ch o ne fo ot

6" 6" th re e qu ar te rs in ch o ne fo ot on e ha lf in ch o ne fo ot th re e ei gh th s in ch o ne fo ot on e qu ar te r i nc h on e fo ot

VA FORM 08-6231

1 2 3 4 5 6 87 9

97 8654321

DRAWING TITLE PROJECT TITLE

LOCATION

DATE CHECKED DRAWN

DRAWING NUMBER

BUILDING NUMBER

PROJECT NUMBER

REVISION DATE

SYRACUSE

VA MEDICAL

CENTER

ENGINEERING

DEPARTMENT

800 IRVING AVE. SYRACUSE, NY 13210

03/31/2023

GENERAL PROJECT INFORMATION

100% SPRINKLERED

DWG.

U.S. Department of Veterans Affairs

B

A

C

D

E

F

528A7-23-105REPLACE ROOF 43

100% DRAWING DOC 02 OF 06

GC-101

KWDW

INFECTION CONTROL (ICRA) PLAN

N

INFECTION CONTROL (ICRA) AT

FIRST FLOOR ENTRANCE

SCALE: 1/8" = 1'-0"1

ROOF 43 AREA

ARCHITECTURAL ABBREVIATIONS

A LABEL CLASS A DOOR

A/C AIR CONDITION

A/C UNIT AIR CONDITIONING UNIT

A/E ARCHITECT/ENGINEER

AAMA AMERICAN ARCHITECTURAL MANUFACTURERS ASSOCIATION

AB ANCHOR BOLT

ABC AGGREGATE BASE COURSE

AC ASBESTOS CEMENT OR ASPHALTIC CONCRETE

ACI AMERICAN CONCRETE INSTITUTE

ACS DR ACCESS DOOR

ACS FLR ACCESS FLOOR

ACS PNL ACCESS PANEL

ACST ACOUSTIC

ACT ACOUSTICAL CEILING TILE

AD AREA DRAIN

ADA AMERICANS WITH DISABILITIES ACT

ADC AUTOMATIC DOOR CLOSER

ADDL ADDITIONAL

ADDN ADDITION

ADH ADHESIVE

ADJ ADJACENT, ADJOINING, OR ADJUSTABLE

ADMIN ADMINISTRATION

ADB AUTOMATIC DOOR BOTTOM

AFC ABOVE FINISHED COUNTER

AFF ABOVE FINISHED FLOOR

AFG ABOVE FINISHED GRADE

AFS ABOVE FINISHED SLAB

AGA AMERICAN GAS ASSOCIATION

AGC ASSOCIATED GENERAL CONTRACTORS

AGGR AGGREGATE

AHJ AUTHORITY HAVING JURISDICTION

AHR ANCHOR

AHU AIR HANDLING UNIT

AIA AMERICAN INSTITUTE OF ARCHITECTS

AISC AMERICAN INSTITUTE OF STEEL CONSTRUCTION

ALT ALTERNATE

ALT NO ALTERNATE NUMBER

ALUM ALUMINUM

AMP AMPERE

AMT AMOUNT

ANOD ANODIZE

ANSI AMERICAN NATIONAL STANDARDS INSTITUTE

ANT ANTENNA

APA AMERICAN PLYWOOD ASSOCIATION

APPD APPROVED

APPROX APPROXIMATE

APT APARTMENT

AR AS REQUIRED

ARCH ARCHITECT

ASB ASBESTOS

ASI ARCHITECT'S SUPPLEMENTAL INSTRUCTION

ASKLR AUTOMATIC SPRINKLER

ASPH ASPHALT

ASSN ASSOCIATION

ASTM AMERICAN SOCIETY FOR TESTING AND MATERIALS

ATCH ATTACHMENT

ATM AUTOMATIC TELLER MACHINE

ATS AUTOMATIC TRANSFER SWITCH

AUTO AUTOMATIC

AUX AUXILIARY

AV AUDIO VISUAL

AVE AVENUE

AVG AVERAGE

AW ACID WASTE

AWI ARCHITECTURAL WOODWORKING INSTITUTE

AWPA AMERICAN WOOD PRESERVERS' ASSOCIATION

AWS AMERICAN WELDING SOCIETY

AWT ACOUSTICAL WALL TREATMENT

B LABEL CLASS B DOOR

B PL BASE PLATE

BALC BALCONY

BAT BATTEN

BB BULLETIN BOARD

BD BOARD

BD FT BOARD FEET (FOOT)

BEV BEVEL

BHMA BUILDER'S HARDWARE MANUFACTURER'S ASSOCIATION

BI FLD DR BIFOLDING DOORS

BITUM BITUMINOUS

BKG BACKING

BLD BUILD

BLDG BUILDING

BLKT BLANKET

BLVD BOULEVARD

BM BEAM OR BENCHMARK

BOT BOTTOM

BR BEDROOM

BRCG BRACING

BRDG BRIDGING

BRDG JST BRIDGING JOIST

BRG BEARING

BRG PL BEARING PLATE

BRKT BRACKET

BRZ BRONZE

BSMT BASEMENT

BTWN BETWEEN

BU BUSHEL

BUR BUILT-UP ROOFING

C CELSIUS CHANNEL

C CHANNEL CELSIUS

C CONC CAST CONCRETE

C LABEL CLASS C DOOR

C TO C CENTER TO CENTER

CAB CABINET

CAC CEILING ATTENUATION CLASS

CB CATCH BASIN OR CORNER BEAD

CBB CEMENTITIOUS (BACKER) BOARD

CC CUBIC CENTIMETER

CCTV CLOSED CIRCUIT TELEVISION

CCW COUNTERCLOCKWISE

CD CONSTRUCTION DOCUMENTS OR CONTRACT DOCUMENTS

CEM CEMENT

CEM PLAS CEMENT PLASTER

CER CERAMIC

CF CONTRACTOR FURNISHED

CF/CI CONTRACTOR FURNISHED/CONTRACTOR INSTALLED

CF/OI CONTRACTOR FURNISHED/OWNER INSTALLED

CFLG COUNTERFLASHING

CFM CUBIC FEET PER MINUTE

CFMF COLD-FORMED METAL FRAMING

CFS CUBIC FEET PER SECOND

CG CENTER OF GRAVITY OR CORNER GUARD

CGSFU CERAMIC GLAZED STRUCTURAL FACING UNITS

CH BD CHALKBOARD

CHEM CHEMICAL

CHFR CHAMFER

CHK CHECK

CI CAST IRON

CIP CAST-IN-PLACE

CIR CIRCLE

CIRC CIRCULAR

CJ CONSTRUCTION JOINT OR CONTROL JOINT

CL CENTER LINE

CLDG CLADDING

CLG CEILING

CLG HT CEILING HEIGHT

CLR CLEAR

cm² SQUARE CENTIMETER cm³ CUBIC CENTIMETER

CM CONSTRUCTION MANAGEMENT

CMU CONCRETE MASONRY UNIT

CNR CORNER

CNTR COUNTER

CO CARBON MONOXIDE, CERTIFICATE OF OCCUPANCY, CLEANOUT,

OR COMPANY

CO₂ CARBON DIOXIDE

COL COLUMN

COM COMMON

COMB COMBINATION, COMBINED

COMM COMMUNICATION

COMP COMPONENT

CONC CONCRETE

CONC FLR CONCRETE FLOOR

COND CONDENSER OR CONDITION

CONF CONFERENCE

CONN CONNECT

CONSTR CONSTRUCTION

CONT CONTINUE

CONTR CONTRACTOR

COR CONTRACTING OFFICER'S REPRESENTATIVE

COORD COORDINATE

CORR CORRIDOR

CPM CRITICAL PATH METHOD

CPRS COMPRESSIBLE

CPT CARPET

CRS COLD ROLLED STEEL

CRSI CONCRETE REINFORCING STEEL INSTITUTE

CSB CONCRETE SPLASH BLOCK

CSG CASING

CSI CONSTRUCTION SPECIFICATIONS INSTITUTE

CSK COUNTER SUNK

CSMT CASEMENT

CSWK CASEWORK

CT CERAMIC TILE

CTB CERAMIC TILE BASE

CTF CERAMIC TILE FLOOR

CTG COATING

CTR CENTER CONTOUR

CTRL CONTROL

CTV CABLE TELEVISION

CU COPPER C

CU FT CUBIC FEET

CU IN CUBIC INCH

CU YD CUBIC YARD

CURT CURTAIN

CYL CYLINDER

CYL L CYLINDER LOCK

D DEPTH OR PENNY (NAIL)

D LABEL CLASS D DOOR

DAT DATUM

DB DECIBEL

DBL DOUBLE

DBL GLZ DOUBLE GLAZE

DC DIRECT CURRENT

DEG DEGREE

DEL DELETE

DEMO DEMOLITION

DEPT DEPARTMENT

DET DETAIL

DF DRINKING FOUNTAIN

DIA DIAMETER

DIAG DIAGONAL DIAGRAM

DIAG DIAGRAM DIAGONAL

DIFF DIFFERENCE OR DIFFUSER

DIM DIMENSION

DIR DIRECTION

DISP DISPENSER

DIST DISTANCE

DIV DIVIDE OR DIVISION

DL DEAD LOAD

DOC DOCUMENT

DOUG FIR DOUGLAS FIR

DOZ DOZEN

DR DOOR, DRAIN, DRESSING ROOM, OR DRIVE

DR CL DOOR CLOSER

DR FR DOOR FRAME

DR OPNG DOOR OPENING

DS DOWNSPOUT

DSGN DESIGN

DW DISHWASHER

DWG DRAWING

DWTR DUMBWAITER

E EAST

E LABEL CLASS E DOOR

EA EACH

EFF EFFICIENCY

EFS EXTERIOR FINISH SYSTEM

EIFS EXTERIOR INSULATION AND FINISH SYSTEM

EJ EXPANSION JOINT

EL ELEVATION

ELAST ELASTOMERIC

ELEC ELECTRIC

ELEC DR OP ELECTRIC DOOR OPENER

ELEV ELEVATOR

EMER EMERGENCY

EMER SHR EMERGENCY SHOWER

ENCL ENCLOSURE

ENGR ENGINEER

ENVIR ENVIRONMENT

EPA ENVIRONMENTAL PROTECTION AGENCY

EPDM ETHYLENE PROPYLENE DIENE MONOMER

EPO EMERGENCY POWER OFF

EPS EXPANDED POLYSTYRENE BOARD (INSULATION)

EQ EQUAL

EQL SP EQUALLY SPACED

EQUIP EQUIPMENT

EQUIV EQUIVALENT

ERD EXISTING ROOF DRAIN

ESC ESCAPE OR ESCUTCHEON

ESCAL ESCALATOR

ESMT EASEMENT

ESP ESPECIALLY

EST ESTIMATE

ETC AND SO FORTH OR ET CETERA

EW EACH WAY

EWC ELECTRIC WATER COOLER

EWS EYE WASH STATION

EXH EXHAUST

EXIST EXISTING

EXP EXPANSION OR EXPOSED

EXP BT EXPANSION BOLT

EXST GR EXISTING GRADE

EXT EXTERIOR, EXTERNAL, OR EXTINGUISHER

EXT GR EXTERIOR GRADE

F FAHRENHEIT OR FEMALE

FA FIRE ALARM

FAB FABRIC

FAC FACTOR

FACIL FACILITY

FAS FASCIA

FAS BD FASCIA BOARD

FCO FLOOR CLEANOUT

FCTY FACTORY

FD FLOOR DRAIN

FDC FIRE DEPARTMENT CONNECTION

FDTN FOUNDATION

FE FIRE EXTINGUISHER

FEC FIRE EXTINGUISHER CABINET

FF FINISH FACE

FF EL FINISH FLOOR ELEVATION

FF&E FURNITURE, FIXTURE, AND EQUIPMENT

FH FLAT HEAD OR FLAT HEAD SCREWS

FHC FIRE HOSE CABINET

FHMS FLAT HEAD MACHINE SCREW

FHP FULL HEIGHT PARTITION

FHWS FLAT HEAD WOOD SCREW

FIG FIGURE

FIL FILLET

FIN FINISH

FIN FLR FINISH FLOOR

FIN GR FINISH GRADE

FIN WD FINISH WOOD

FIXT FIXTURE

FL FLOORLINE

FLASH FLASHING

FLDG FOLDING

FLEX FLEXIBLE

FLG FLOORING

FLR FLOOR

FLR FIN FLOOR FINISH

FLR SK FLOOR SINK

FLUOR FLUORESCENT

FLUOR FIX FLUORESCENT FIXTURE

FM FACTORY MUTUAL

FM-G FACTORY MUTUAL GLOBAL

FO FINISHED OPENING

FOC FACE OF CONCRETE OR FACE OF CURB

FOF FACE OF FINISH

FOM FACE OF MASONRY

FOS FACE OF SLAB OR FACE OF STUD

FOUNT FOUNTAIN

FOW FACE OF WALL

FP FIRE PROTECTION OR FIREPROOF

FPM FEET PER MINUTE

FPS FEET PER SECOND

FR FIRE RATING, FIRE RESISTANT, OR FRAME

FR SNK FLUSHING RIM SINK

FREQ FREQUENCY

FRMG FRAMING

FRP FIBER REINFORCED POLYESTER OR FIBERGLASS REINFORCED

PLASTIC

FRZ FREEZER

FS FEDERAL SPECIFICATION

FSTNR FASTENER

FT FEET OR FOOT

FTG FOOTING

FURG FURRING

FURN FURNISH OR FURNITURE

FUT FUTURE

FWC FABRIC WALLCOVERING

GA GAGE OR GYPSUM ASSOCIATION

GAL GALLON

GALV GALVANIC OR GALVANIZED

GALV STL GALVANIZED STEEL

GB GRAB BAR

GC GENERAL CONTRACTOR

GD GUARD

GDR GUARD RAIL

GEN GENERAL OR GENERATOR

GFRC GLASS-FIBER-REINFORCED CONCRETE

GFRG GLASS-FIBER-REINFORCED GYPSUM

GFRP GLASS-FIBER-REINFORCED PLASTIC

GI GALVANIZED IRON

GL GLASS

GL BLK GLASS BLOCK

GLU LAM GLUED LAMINATED WOOD

GR FL GROUND FLOOR

GRAN GRANITE

GRTG GRATING

GSB GYPSUM SHEATHING BOARD

GSM GALVANIZED SHEET METAL

GSU GLAZED STRUCTURAL UNIT

GT GROUT

GUAR GUARANTEE

GUT GUTTER

GYP GYPSUM

GYP BD GYPSUM BOARD

GYP PLAS GYPSUM PLASTER

H HIGH

H PLAM HIGH PRESSURE PLASTIC LAMINATE

HAZ MAT HAZARDOUS MATERIALS

HB HOSE BIBB

HC HOLLOW CORE

HCWD HOLLOW CORE WOOD DOOR

HDBD HARDBOARD

HDNR HARDENER

HDO HIGH DENSITY OVERLAY

HDR HEADER

HDW HARDWARE

HDWD HARDWOOD

HEPA HIGH EFFICIENCY PARTICULATE AIR (FILTER)

HEX HEXAGON

HF HIGH FREQUENCY

HGR HANGER

HM HECTOMETER

HM HOLLOW METAL

HMD HOLLOW METAL DOOR

HMDF HOLLOW METAL DOOR AND FRAME

HMF HOLLOW METAL FRAME

HNDRL HANDRAIL

HO HOLD OPEN

HORIZ HORIZONTAL

HOSP HOSPITAL

HP HIGH PRESSURE OR HORSEPOWER

HQ HEADQUARTERS

HS HEAT-STRENGTHENED (GLASS) OR HIGH STRENGTH

HSE HOUSE

HSKPG HOUSEKEEPING

HST HOIST

HT HEIGHT

HVAC HEATING, VENTILATING, AND AIR CONDITIONING

HVY HEAVY

HW HOT WATER

HYD HYDRANT

HYDR HYDRAULIC

I INTERSTATE (HIGHWAY) OR MOMENT OF INERTIA

IAQ INDOOR AIR QUALITY

IBC INTERNATIONAL BUILDING CODE

ID IDENTIFICATION, INSIDE DIAMETER, OR INTERIOR DESIGN

ID NO IDENTIFICATION NUMBER

ILLUM ILLUMINATION

INCL INCLUDED

IND INDEPENDENT OR INDUSTRIAL

INFO INFORMATION

INSUL INSULATION

INT INTERIOR

INTERCOM INTERCOMMUNICATION

INTL INTERNATIONAL

IRMA INVERTED ROOF MEMBRANE ASSEMBLY

IWH INSTANTANEOUS WATER HEATER

JAN JANITOR

J-BOX JUNCTION BOX

KD KILN DRIED OR KNOCKED DOWN

KIT KITCHEN

KO KNOCKOUT

KPL KICKPLATE

L ANGLE

LAB LABORATORY

LAD LADDER

LAM LAMINATE

LAM GL LAMINATED GLASS

LAU LAUNDRY

LAV LAVATORY

LBR LUMBER

LBS POUND

LD BRG LOAD-BEARING

LDR LEADER

LED LIGHT EMITTING DIODE

LF LINEAR FEET (FOOT)

LH LEFT HAND

LHR LEFT HAND REVERSE

LHR LEFT HAND REVERSE LATENT HEAT RATIO

LIB LIBRARY

LIN LINEAR

LINO LINOLEUM

LIQ LIQUID

LKR LOCKER

LKR RM LOCKER ROOM

LKWASH LOCKWASHER

LL LEAD LINED

LLH LONG LEG HORIZONTAL

LLV LONG LEG VERTICAL

LMST LIMESTONE

LNDSCP LANDSCAPE

LR LIVING ROOM

LRG LARGE

LRV LOUVERED ROOF VENT

LS LUMP SUM

LT LIGHT

LT GA LIGHT GAGE

LT WT LIGHTWEIGHT

LTG LIGHTING

LTNG LIGHTNING

LVD LOUVERED

LVR LOUVER

LWC LIGHTWEIGHT CONCRETE

LWIC LIGHTWEIGHT INSULATING CONCRETE

LYR LAYER

MACH MACHINE

MACH RM MACHINE ROOM

MAINT MAINTENANCE

MAN MANUAL

MATL MATERIAL

MATV MASTER ANTENNA TELEVISION SYSTEM

MAX MAXIMUM

MB MACHINE BOLT

MCB METAL CORNER BEAD

MD DECK

ME MECHANICAL ENGINEER

MEAS MEASURE

MECH MECHANICAL

MECH RM MECHANICAL ROOM

MED MEDICAL MEDIUM

MED MEDIUM MEDICAL

MEK METHYL ETHYL KETONE

MEL MELAMINE

MEMB MEMBRANE

MEMO MEMORANDUM

MEZZ MEZZANINE

MF MILL FINISH

MFD MANUFACTURED

MFG MANUFACTURING

MFR MANUFACTURER

MFR REC MANUFACTURER'S RECOMMENDATION

MGT MANAGEMENT

MH MANHOLE

MIC MICROPHONE

MID MIDDLE

MIL STD MILITARY STANDARD

MIN MINIMUM MINUTE

MIN MINUTE MINIMUM

MIRR MIRROR

MISC MISCELLANEOUS

MIT MITER

MKR MARKER

ML METAL LATH

MLDG MOLDING (MOULDING)

MLWK MILLWORK

mm MILLIMETER

MO MASONRY OPENING OR MOTOR OPERATED

MOD MODEL, MODIFY OR MODULE

MOD BIT MODIFIED BITUMEN

MON MONITOR

MOPR MOP RACK

MR MOISTURE RESISTANT

MS MACHINE SCREW OR MOP SINK

MTD MOUNTED

MTG MOUNTING

MTL METAL

MULL MULLION

MW MICROWAVE

MWP MEMBRANE WATERPROOFING

N NORTH

NA NOT APPLICABLE

NAAMM NATIONAL ASSOCIATION OF ARCHITECTURAL METAL

MANUFACTURERS

NAT NATURAL

NATL NATIONAL

NC NOISE CRITERIA

NCOMBL NONCOMBUSTIBLE

NEC NATIONAL ELECTRICAL CODE

NEG NEGATIVE

NEMA NATIONAL ELECTRICAL MANUFACTURERS ASSOCIATION

NEUT NEUTRAL

NFC NATIONAL FIRE CODE

NFPA NATIONAL FIRE PROTECTION ASSOCIATION

NIC NOT IN CONTRACT

NO NUMBER

NOM NOMINAL

NR NOISE REDUCTION

NRC NOISE REDUCTION COEFFICIENT

NRCA NATIONAL ROOFING CONTRACTORS ASSOCIATION

NRP NONREMOVABLE

NS NARROW STILE

NUM NUMERAL

O/O OUT TO OUT

O OXYGEN

OA OUTSIDE AIR OR OVERALL

OC ON CENTER

OCC OCCUPY

OCT OCTAGON

OD OUTSIDE DIAMETER OUTSIDE DIMENSION

OD OUTSIDE DIMENSION OUTSIDE DIAMETER

OF/CI OWNER FURNISHED/CONTRACTOR INSTALLED

OFD OVERFLOW DRAIN

OFF OFFICE

OF/OI OWNER FURNISHED/OWNER INSTALLED

OH OVERHANG

OH DR OVERHEAD (COILING) DOOR

OPH OPPOSITE HAND

OPNG OPENING

OPP OPPOSITE

OPR OPERABLE

OPT OPTIONAL

OR OPERATING ROOM OR OUTSIDE RADIUS

ORD ORDNANCE OR OVERFLOW ROOF DRAIN

ORG ORGANIC

ORIG ORIGINAL

ORN ORNAMENTAL

OSHA OCCUPATIONAL SAFETY AND HEALTH ADMINSTRATION

OUT OUTLET

OZ OUNCE

PAR PARALLEL OR PARAPET

PARA PARAGRAPH

PART PARTIAL

PAT PATTERN

PB PUSHBUTTON

PBD PARTICLEBOARD

PC PIECE, POLYCARBONATE OR PORTLAND CEMENT

PCA PORTLAND CEMENT ASSOCIATION

PCC PRECAST CONCRETE

PCCP CONCRETE PAVEMENT

PCD PAPER CUP DISPENSER

PCF POUNDS PER CUBIC FOOT

PCP PORTLAND CEMENT PLASTER

PED PEDESTAL

PEN PENETRATE

PEND PENDANT

PERF PERFORATED

PERIM PERIMETER

PERP PERPENDICULAR

PGBD PEGBOARD

PHAR PHARMACY

PHOTO PHOTOGRAPH

PHS PHILLIPS HEAD SCREW

PKG PACKAGE

PL PROPERTY LINE

PL GL PLATE GLASS

PLAM PLASTIC LAMINATE

PLAS PLASTER OR PLASTIC

PLBG PLUMBING

PLYWD PLYWOOD

PMTL PAINTED METAL

PNEU PNEUMATIC

PNL PANEL

PO POST OFFICE PURCHASE ORDER

PO PURCHASE ORDER POST OFFICE

POLY POLYETHYLENE (PLASTIC)

PR PAIR

PRCST PRECAST

PREFAB PREFABRICATE

PREFIN PREFINISH

PRELIM PRELIMINARY

PREP PREPARATION

PRESS PRESSURE

PREV PREVIOUS

PRKG PARKING

PRMLD PREMOLDED

PROJ PROJECT

PROP PROPERTY

PSF POUNDS PER SQUARE FOOT

PSI POUNDS PER SQUARE INCH

PT PAINT, PNEUMATIC TUBE, OR PRESSURE TREATED

PTD PAPER TOWEL DISPENSER

PTN PARTITION

PVC POLYVINYL CHLORIDE (PLASTIC)

PVG PAVING

PWR POWER

QA QUALITY ASSURANCE

QC QUALITY CONTROL

QRY QUARRY

QT QUARRY TILE

QTB QUARRY TILE BASE

QTF QUARRY TILE FLOOR

QTR QUARTER

QTY QUANTITY

QUAD QUADRANT

QUAL QUALITY

R RADIUS OR RISER

RA RETURN AIR

RAD RADIATOR

RB RESILIENT BASE OR RUBBER BASE

RB HK ROBE HOOK

RBM REINFORCED BRICK MASONRY

RBR RUBBER

RC REMOTE CONTROL

RCP REFLECTED CEILING PLAN

RCVR RECEIVER

RD ROAD OR ROOF DRAIN

REC RECESSED

RECD RECEIVED

RECPT RECEPTACLE

RECT RECTANGLE

REF REFERENCE OR REFRIGERATOR

REFR REFRACTORY REFRIGERATION

REFR REFRIGERATION REFRACTORY

REG REGISTER

REINF REINFORCE

REP REPAIR

REPL REPLACE

REQ REQUIRE

REQD REQUIRED

RESIL RESILIENT

RET RETURN

REV REVISION

RF RADIO FREQUENCY

RFG ROOFING

RFI REQUEST FOR INFORMATION

RFP REQUEST FOR PROPOSAL

RH RIGHT HAND

RHMS ROUND HEAD MACHINE SCREW

RHR RIGHT HAND REVERSE

RHWS ROUND HEAD WOOD SCREW

RL ROOF LEADER

RLG RAILING

RM ROOM

RND ROUND

RO ROUGH OPENING

ROW RIGHT OF WAY

RPM REVOLUTIONS PER MINUTE

RS ROUGH SAWN

RT RIGHT

RV ROOF VENT

RVS REVERSE

RWD REDWOOD

RWL RAIN WATER LEADER

SA SUPPLY AIR

SALV SALVAGE

SAMP SAMPLE

SAN SANITARY

SAT SUSPENDED ACOUSTICAL TILE

SATC SUSPENDED ACOUSTICAL TILE CEILING

SB SPLASH BLOCK

SBS STYRENE BUTADIEN STYRENE

SBSTR SUBSTRATE

SC SHADING COEFFICIENT OR SOLID CORE

SCH SCHOOL

SCHED SCHEDULE

SCHEM SCHEMATIC

SCP SCUPPER

SCRN SCREEN

SCT STRUCTURAL CLAY TILE

SCWD SOLID CORE WOOD DOOR

SD SHOP DRAWINGS, SMOKE DETECTOR, OR SOAP DISPENSER

SDG SIDING

SECT SECTION

SEG SEGMENT

SEL SELECT

SEP SEPARATE

SF SQUARE FOOT (FEET)

SFTWD SOFTWOOD

SGD SLIDING GLASS DOOR

SGL SINGLE

SHR SHOWER

SHR HD SHOWER HEAD

SHRD SHOWER DRAIN

SHT SHEET

SHT MTL FLASH SHEET METAL (FLASHING)

SHTHG SHEATHING

SHV SHELVING

SIM SIMILAR

SJ SCORED JOINT

SJI STEEL JOIST INSTITUTE

SK SKETCH

SKLT SKYLIGHT

SLD WDW HORIZONTAL SLIDING WINDOW

SLDG SLIDING

SLNT SEALANT

SM SHEET METAL

SMK SMOKE

SND SANITARY NAPKIN DISPENSER

SND INS SOUND INSULATION

SNDU SANITARY NAPKIN DISPOSAL UNIT

SPEC SPECIFICATION

SPKLR SPRINKLER

SPKR SPEAKER

SPLY SUPPLY

SQ SQUARE

SQ IN SQUARE INCH

SQ YD SQUARE YARD

SS SANITARY SEWER OR SERVICE SINK

SST STAINLESS STEEL

ST STAIRS OR STREET

STC SOUND TRANSMISSION CLASS

STD STANDARD

STIF STIFFENER

STL JST STEEL JOIST

STL LNTL STEEL LINTEL

STL PL STEEL PLATE

STL RF DK STEEL ROOF DECK

STL TB STEEL TUBE

STL TR STEEL TRUSS

STNLS STAINLESS

STOR STORAGE

STR STRINGERS

STRUCT STRUCTURAL

STRUCT STL STRUCTURAL STEEL

SUB SUBSTITUTE

SURF SURFACE

SUSP SUSPEND

SUSP CLG SUSPENDED CEILING

SV SHEET VINYL

SW SWITCH

SWDR SWING DOOR

SYM SYMBOL

SYNTH SYNTHETIC

SYS SYSTEM

T TREAD

T&G TONGUE AND GROOVE

T&M TIME AND MATERIALS

TB THROUGH BOLT OR TOWEL BAR

TCA TILE COUNCIL OF AMERICA

TCP TELEPHONE CONTROL PANEL TEMPERATURE CONTROL

PANEL; TRAFFIC CONTROL PLAN

TD TOWEL DISPENSER

TECH TECHNICAL

TEL TELEPHONE

TEMP TEMPERATURE OR TEMPORARY

TER TERRAZZO

THD THREAD

THERM THERMAL

THK THICKNESS

THRES THRESHOLD

THRU THROUGH

THRUOUT THROUGHOUT

TK BD TACKBOARD

TMPD TEMPERED

TMPD GL TEMPERED GLASS

TN TRUE NORTH

TO TOP OF ___

TO FDN TOP OF FOUNDATION

TOB TOP OF BEAM

TOM TOP OF MASONRY

TOP TOP OF PARAPET

TOS TOP OF STEEL

TOW TOP OF WALL

TPD TOILET PAPER DISPENSER

TPH TOILET PAPER HOLDER

TR TOWEL RACK

TRANS TRANSOM

TRANS WD FIN TRANSPARENT WOOD FINISH

TRTD TREATED

TS TENSILE STRENGTH OR TUBE STEEL

TSTAT THERMOSTAT

TV TELEVISION

TYP TYPICAL

U HEAT TRANSFER COEFFICIENT

UC UNDERCUT

UCD UNDERCUT DOOR

UGND UNDERGROUND

UL UNDERWRITERS LABORATORIES

ULT ULTIMATE

UNFIN UNFINISH

UON UNLESS OTHERWISE NOTED

UPS UNINTERRUPTIBLE POWER SUPPLY

UR URINAL

UTIL UTILITY

UV ULTRAVIOLET

V VOLT

VAC VACUUM

VAR VARIES

VCT VINYL COMPOSITION TILE VITRIFIED CLAY TILE

VEH VEHICLE

VENT VENTILATION

VERT VERTICAL

VEST VESTIBULE

VFAT VINYL FACED ACOUSTICAL TILE

VIC VICINITY

VID VIDEO

VIF VERIFY IN FIELD

VNR VENEER

VOC VOLATILE ORGANIC COMPOUND

VOL VOLUME

VOLT VOLTAGE

VP VENEER PLASTER

VR VAPOR RETARDER

VTR VENT THROUGH ROOF

VWC VINYL WALL COVERING

VWF VINYL WALL FABRIC

W WIDE OR WEST

W/ WITH

W/O WITHOUT

WARR WARRANTY

WBL WOOD BLOCKING

WC WALL COVERING OR WATER CLOSET

WC WL HNG WATER CLOSET, WALL HUNG

WCHR WATER CHILLER

WCL WL MTD WATER COOLER, WALL HUNG

WD WOOD

WDW WINDOW

WF WIDE FLANGE

WFAB WALL FABRIC

WFR WOOD FRAME

WFS WOOD FURRING STRIPS

WH WATER HEATER

WHSE WAREHOUSE

WLD WELDED

WM WIRE MESH

WP WATERPROOFING

WPD WATER PRESSURE DROP

WPM WATERPROOF MEMBRANE

WR WEATHER RESISTANT

WS WEATHERSTRIP

WSCT WAINSCOT

WT WEIGHT

WWF WELDED WIRE FABRIC

X BRACE CROSS BRACE

XPS EXTRUDED POLYSTYRENE BOARD (INSULATION)

YD YARD

YR YEAR

CONTRACT LIMIT LINE

FIRE RESISTIVE RATED LINE, 4 HOUR

DEMOLITION LINE

ELEVATION INDICATOR OR DATUM

CENTER LINE INDICATOR

EXISTING TO REMAIN LINE

FEATURES ABOVE LINE INDICATOR

FIRE RESISTIVE RATED LINE, 1 HOUR

FIRE RESISTIVE RATED LINE, 2 HOUR

FIRE RESISTIVE RATED LINE, 3 HOUR

FIRE-RATED, SMOKE BARRIER LINE, 1 HOUR

FIRE-RATED, SMOKE BARRIER LINE, 2 HOUR

FIRE-RATED, SMOKE BARRIER LINE, 4 HOUR

HIDDEN FEATURES LINE

NEW LINE

PROPERTY LINE

SMOKE BARRIER LINE

BREAK, ROUND (USER DEFINES SIZE)

BREAK, STRAIGHT (SEE SECTION INDICATORS,

BUILDING, WITH BREAK STANDARDS)

DETAIL INDICATOR

DETAIL INDICATOR

DETAIL INDICATOR FOR SMALL CONDITIONS

DIMENSION LINE

DOOR OPENING / BORROWED LIGHT IDENTIFIER

DRAWING BLOCK OR DETAIL TITLE, TYPICAL

ELEVATION INDICATOR, EXTERIOR

ELEVATION INDICATOR; INTERIOR, MULTIPLE VIEW

ELEVATION INDICATOR, INTERIOR, SINGLE VIEW

ARCHITECTURAL SYMBOLS

CENTER LINE

FURNITURE, FIXTURE, & EQUIPMENT INDICATOR

GRAPHIC SCALE; 18"=1'-0"

FIRE-RATED, SMOKE BARRIER LINE, 3 HOUR

A-201 A4

S

S

S

S

C2

CORRIDOR ROOM NAME AND NUMBER

A

CG

COLUMN GRID

KEYNOTE

WALL OR PARTITION TYPE

FIRE EXTINGUISHER CABINET

CORNER GUARD

NORTH ARROW

EXISTING CONSTRUCTION

TO REMAIN

EXISTING CONSTRUCTION

TO BE REMOVED

NEW CONSTRUCTION

CONCRETE

COMPACTED EARTH

BASE COURSE

RIGID

INSULATION

BATT

INSULATION

V V ITEM - VA SUPPLIED & INSTALLED

VC ITEM - VA SUPPLIED & CONTRACTOR INSTALLED

CC ITEM - CONTRACTOR SUPPLIED & INSTALLED

DETAIL NUMBER

SHEET WHERE REF.

SHEET WHERE DRAWN

BUILDING SECTION INDICATOR

DETAIL INDICATOR

MATERIALS LEGEND

D2 A-512

D2 A-512

A-202 A2

A4 A-201

A4 A-201

AA

NORTH

10'-0"

A

C B

D

FEC

A-202 A2

A3.1 A4.3

16'8'4'0

C4 DRAWING BLOCK TITLE

1" = 1 1/2"

C3XXX

D2 A-512

UNDISTURBED EARTH

121212

NOTE:

SYMBOL LIST SHOWN IS FOR GENERAL

REFERENCE ONLY. THE PRESENCE OF A

SYMBOL DOES NOT IMPLY ITS USE ON THIS

PROJECT. REFER TO THE DRAWINGS FOR

SPECIFIC SYMBOLS USED.

on e ei gh th in ch o ne fo ot

B

A

C

D

E

F th re e in ch es o ne fo ot 6"

6" on e an d on e ha lf in ch es o ne fo ot on e in ch o ne fo ot

6" 6" th re e qu ar te rs in ch o ne fo ot on e ha lf in ch o ne fo ot th re e ei gh th s in ch o ne fo ot on e qu ar te r i nc h on e fo ot

VA FORM 08-6231

1 2 3 4 5 6 87 9

97 8654321

DRAWING TITLE PROJECT TITLE

LOCATION

DATE CHECKED DRAWN

DRAWING NUMBER

BUILDING NUMBER

PROJECT NUMBER

REVISION DATE

SYRACUSE

VA MEDICAL

CENTER

ENGINEERING

DEPARTMENT

800 IRVING AVE. SYRACUSE, NY 13210

03/31/2023

GENERAL PROJECT INFORMATION

100% SPRINKLERED

DWG.

U.S. Department of Veterans Affairs

B

A

C

D

E

F

528A7-23-105REPLACE ROOF 43

100% DRAWING DOC 03 OF 06

A-001

KAWDW

ARCHITECTURAL ABBREVIATIONS &

SYMBOLS

100% SPRINKLERED

EF-07

EF-08

EXIST. LIGHTNING

PROTECTION CABLE

LOOP (V.I.F.)

MAIN ENTRANCE

ROOF 2333 SF

170 LF OUTSIDE

MAIN ENTRANCE

ROOF 347 SF

MAIN ENTRANCE

ROOF 567 SF

on e ei gh th in ch o ne fo ot

B

A

C

D

E

F th re e in ch es o ne fo ot 6"

6" on e an d on e ha lf in ch es o ne fo ot on e in ch o ne fo ot

6" 6" th re e qu ar te rs in ch o ne fo ot on e ha lf in ch o ne fo ot th re e ei gh th s in ch o ne fo ot on e qu ar te r i nc h on e fo ot

VA FORM 08-6231

1 2 3 4 5 6 87 9

97 8654321

DRAWING TITLE PROJECT TITLE

LOCATION

DATE CHECKED DRAWN

DRAWING NUMBER

BUILDING NUMBER

PROJECT NUMBER

REVISION DATE

SYRACUSE

VA MEDICAL

CENTER

ENGINEERING

DEPARTMENT

800 IRVING AVE. SYRACUSE, NY 13210

03/31/2023

GENERAL PROJECT INFORMATION

100% SPRINKLERED

DWG.

U.S. Department of Veterans Affairs

B

A

C

D

E

F

528A7-23-105REPLACE ROOF 43

100% DRAWING DOC 04 OF 06

AD-101

KWDW

ARCHITECTURAL ROOF DEMOLITION

PLAN

N

ARCHITECTURAL DEMOLITION FLOOR PLAN

SCALE: 1/8" = 1'-0"1

GENERAL REMOVAL NOTES:

1. THE DEMOLITION AND ALTERATION NOTES ON THIS PLAN SHALL NOT BE DEEMED

TO BE ALL-INCLUSIVE. PRIOR TO THE START OF DEMOLITION INSPECT AND ASSESS

EACH AREA TO FULFILL THE DESIGN INTENT OF THE WORK INDICATED BY THE

PROJECT DOCUMENTS.

2. VERIFY ALL CONDITIONS AND DIMENSIONS WITHIN THE PROJECT LIMITS AND

NOTIFY THE VAMC COR IMMEDIATELY OF ANY DEVIATION FROM PROJECT

DOCUMENTS NECESSITATED BY FIELD CONDITIONS OR ITEMS NOT COVERED.

3. FOR ALL SURFACES SCHEDULED TO REMAIN, PATCH, MATCH SURFACES

DISTURBED BY DEMOLITION OR REMOVAL OF EQUIPMENT OR UTILITIES. PROVIDE

PATCHING TO MATCH ADJACENT WORK IN FINISH, STRUCTURAL QUALITIES,

COURSING OF MASONRY AND OTHER CHARACTERISTICS. PATCH SURFACES TO

COMPLY WITH FIRE RATINGS, SMOKE-TIGHT RATINGS, ACOUSTICAL CRITERIA AND

OTHER PERFORMANCE CRITERIA INDICATED. PREPARE SURFACES AS NECESSARY

TO PROVIDE A PROPER SUBSTRATE FOR SPECIFIED FINISH. REFINISH ENTIRE

SURFACE CORNER TO CORNER TO PROVIDE AN EVEN FINISH. ALL WORK SHALL

REFLECT HIGHEST LEVEL OF INDUSTRY STANDARDS FOR EACH TRADE.

4. ALL DEMOLITION SHALL BE PERFORMED IN A SAFE AND ACCEPTABLE MANNER TO

ALL AUTHORITIES HAVING JURISDICTION AND THE SYRACUSE VAMC. A FIRE WATCH

SHALL BE PROVIDED AS REQUIRED BY SYRACUSE VAMC AND APPLICABLE CODES.

5. HAZARDOUS MATERIAL NOTE: STOP WORK AND INFORM VAMC COR IMMEDIATELY

OF ANY HAZARDOUS MATERIAL ENCOUNTERED OR THOUGHT TO BE HAZARDOUS.

VAMC COR SHALL INSTRUCT CONTRACTOR ON HOW TO PROCEED.

6. ALL WORK SHALL BE DONE IN PROTECTED SPACE. NO DUST, DIRT OR LIQUID SHALL

TRAVEL FROM CONSTRUCTION AREA TO ADJACENT AREAS. TEMPORARY ICRA

PARTITIONS SHALL BE ERECTED PRIOR TO COMMENCING WORK.

7. PRIOR TO ANY DEMOLITION, COORDINATE BRACING AND MAINTAIN THE

STRUCTURAL INTEGRITY OF THE REMAINING ELEMENTS OF THE BUILDING AND ITS

SYSTEMS AS REQUIRED.

8. COMPLY WITH GOVERNING REGULATIONS PERTAINING TO ENVIRONMENTAL

PROTECTION FOR POLLUTION CONTROL. THOROUGHLY CLEAN ADJACENT AREAS

OF DUST, DIRT AND DEBRIS CAUSED BY DEMOLITION WORK. BEFORE NEW WORK

BEGINS, RETURN ADJACENT AREAS TO CONDITION FOUND PRIOR TO START OF

DEMOLITION WORK.

9. REVIEW ALL ITEMS TO BE DEMOLISHED WITH VAMC COR TO IDENTIFY ANY ITEMS TO

BE SALVAGED PRIOR TO START OF DEMOLITION.

10. MAINTAIN ACCESS TO EXITS AND EXIT STAIRS AT ALL TIMES. FIRE ALARM AND

SMOKE DETECTION SYSTEM SHALL REMAIN OPERATIONAL AT ALL TIMES. PROTECT

SMOKE DETECTORS AS REQUIRED AND IN CONFORMANCE WITH CODES AND LOCAL

AUTHORITIES HAVING JURISDICTION.

11. PRIOR TO DEMOLITION, PERFORM A THOROUGH ABOVE-CEILING INSPECTION FOR

EXISTING SERVICES THAT ARE TO REMAIN AND NOTIFY VAMC COR IMMEDIATELY OF

ANY CONFLICTS WITH INSTALLATION OF NEW WORK.

12. THE CONTRACTOR IS REQUIRED TO ENSURE THAT THE SMOKE AND FIRE BARRIER

IS FULLY MAINTAINED THROUGHOUT THE DURATION OF THE PROJECT. THIS IS TO

INCLUDE FILLING ANY EXISTING OPENINGS WITHIN THE SMOKE AND FIRE BARRIER.

THE CONTRACTOR SHALL REVIEW THIS PRIOR TO THE BID.

13. COMPLY WITH WASTE MANIFEST REQUIREMENTS SEE SPECIFICATION 01-74-19.

14. ANY LIGHTING ARRECTOR DEVICES REMOVED WILL NEED TO BE RE-INSTALLED TO

CODE NFPA 780.

R1

R2

KEYED REMOVAL NOTES

REMOVE BITUMINOUS BUILT-UP ROOFING AND ROOF ACCESSORIES DOWN TO CLEANED

CONCRETE ROOF DECK SURFACE. REMOVE AND DISCARD ROOF DRAIN. PREPARE DECK TO

RECEIVE SCHEDULED ROOFING SYSTEM.

REMOVE EXISTING BLOCKING AND FASCIA. PREPARE WALL TO RECEIVE SCHEDULED

WORK.

REMOVE EXISTING ALUMINUM REGLET FRAME. PREPARE WALL TO RECEIVE SCHEDULED

WORK.

PROTECT EQUIPMENT FROM DEBRIS.

R3

R1

R1

R1

R2

R2

R2

R2

R1

R3

R3

R3

R1

R1

R1

R1

R3

R3

R2

R2

R2

R2

R2

R2

R4

R4

R4

RAKE OUT EXISTING MORTAR JOINT REQUIRED TO INSTALL REGLET

ALUMINUM REGLET FRAME & COUNTERFLASHING W/

S.S. WIND CLIPS @ 32" O.C. MAX. BY MM

SYSTEMS CORP. RC-3 OR APPROVED EQUAL.

SEAL TOP OF FLASHING W/ FABRIC & MASTIC.

CONT. P.T. WOOD CANT SET IN

BITUMEN

TYPICAL WHERE 1 STORY ROOF ABUTS

TO BACK OF WALL

TOP OF ROOF DECK

ROOF ELEV. VARIES

MIN 8" ABOVE ROOF

TOP OF BASE FLASHING

ROOF

INSULATION

PITCH 18" PER FOOT

TAPERED INSULATION

AVG. VALUE R30

PROVIDE BLOCKING AS NECESSARY

SEE DETAIL 4/A-101

FULLY ADHERED EPDM MEMBRANE

NON-CURING SEALANT

FASCIA COVER

(12'-0" LENGTHS)

NOTE:

HOLES PREPUNCHED 1 1/4"

DOWN, CENTERED IN 1st NAILER.

FLASHING STRIP

PITCH 18" PER FOOT

T.O.W.

ANCHOR BAR

EXTRUDED

#10X2" STAINLESS

STEEL FASTENERS

12" O.C.

1/4" X 1 1/4" MASONRY/WOOD FASTENERS 24" O.C.

(PROVIDED)

20 GA. GALV. CONTINUOUS CLEAT

CANT

2" COVERBOARD

EXISTING CONCRETE DECK

R30 AVERAGE MECHANICALLY FASTENED RIGID INSULATION

EXISTING

CONCRETE

BLOCKS TO

REMAIN

.050" ALUMINUM GRAVEL STOP

2X WOOD BLOCKING, TYP.

ADHESIVE SEALANT JOINT

VARIES

PRE-FINISHED METAL REGLET FORMED

IN 10-FT. LENGTHS

BACKER ROD AND SEALANT BY OTHERS

MEMBRANE BY OTHERS

PRE-FINISHED COUNTER-FLASHING FORMED IN 10-FT.

LENGTHS

6-1/4-IN.

2-1/2-IN.

MIN=1

MAX=5

RD

RD

RD

MAIN ENTRANCE

ROOF 2333 SF

170 LF OUTSIDE

8" / 12"

SLOPE

19.1 18 " / 12"

SLO

PE

18 " / 12"

SLO

PE

8" / 12"

SLOPE

18 " / 12"

SLO

PE

8" / 12"

SLOPE1

8" / 12"

SLOPE

8" / 12"

SLOPE

18 " / 12"

SLO

PE

8" / 12"

SLOPE

1 8"

SL

O

PE

EXIST. LIGHTNING

PROTECTION CABLE

LOOP (V.I.F.)

NEW. LIGHTNING

PROTECTION CABLE

LOOP (V.I.F.)

NEW. LIGHTNING

PROTECTION CABLE

LOOP (V.I.F.)

MAIN ENTRANCE

ROOF 347 SF

24 LF

MAIN ENTRANCE

ROOF 567 SF

102 LF OUTSIDE

on e ei gh th in ch o ne fo ot

B

A

C

D

E

F th re e in ch es o ne fo ot 6"

6" on e an d on e ha lf in ch es o ne fo ot on e in ch o ne fo ot

6" 6" th re e qu ar te rs in ch o ne fo ot on e ha lf in ch o ne fo ot th re e ei gh th s in ch o ne fo ot on e qu ar te r i nc h on e fo ot

VA FORM 08-6231

1 2 3 4 5 6 87 9

97 8654321

DRAWING TITLE PROJECT TITLE

LOCATION

DATE CHECKED DRAWN

DRAWING NUMBER

BUILDING NUMBER

PROJECT NUMBER

REVISION DATE

SYRACUSE

VA MEDICAL

CENTER

ENGINEERING

DEPARTMENT

800 IRVING AVE. SYRACUSE, NY 13210

03/31/2023

GENERAL PROJECT INFORMATION

100% SPRINKLERED

DWG.

U.S. Department of Veterans Affairs

B

A

C

D

E

F

528A7-23-105REPLACE ROOF 43

100% DRAWING DOC 05 OF 06

A-101

KWDW

ARCHITECTURAL ROOF PLAN

N

ARCHITECTURAL FLOOR PLAN

SCALE: 1/8" = 1'-0"1 ROOF TO WALL BASE FLASHING

SCALE: 1-1/2" = 1'-0"2

TYPICAL EDGE DETAIL

SCALE: 3" = 1'-0"3

REGLET DETAIL

SCALE: NTS4

ROOF PLAN KEYED NOTES:

INSTALL TAPERED RIGID INSULATION AVERAGE R30, 12" COVERBOARD, FULLY

ADHERED EPDM MEMBRANE, ASSOCIATED ROOF ACCESSORIES, AND ROOF DRAIN.

INSULATION INSULATION TO BE A MIN. OF 2" AT ROOF DRAIN. SEE DETAILS.

INSTALL BLOCKING AS NECESSARY WITH ASSOCIATED TRIM AS NECESSARY.

INSTALL NEW ROOF DRAIN. TIE INTO EXISTING DRAIN PIPE.

ADD LIGHTING PROTECTIONS TO ROOF. SEE DETAIL 16/ A-501

REPLACE AND INSTALL ALL FLASHING AROUND ROOFS SHOWN.

GENERAL DRAWING NOTES:

1. FOLLOW ALL INFECTION CONTROL PROCEDURES AND TEMPORARY CONSTRUCTION DEFINED IN PROJECT

SPECIFICATION & VA APPROVED ICRA.

2. PROVIDE THOROUGH CLEANING FOLLOWING EACH WORK DAY. CONTRACTOR IS REQUIRED TO ENSURE THE

PROJECT SITE IS CLEANED REGULARLY THROUGHOUT THE WORKING DAY.

3. VERIFY ALL EXISTING CONDITIONS AND ESTABLISHING THE COMPATIBILITY OF ALL NEW WORK WITH THE

EXISTING CONDITIONS.

4. ALL WORK IS BEING DONE ADJACENT TO, AND ABOVE, OCCUPIED SPACE. TAKE EVERY PRECAUTION TO ELIMINATE THE TRAVEL OF LIQUID, DUST AND DIRT FROM THECONSTRUCTION AREA TO THOSE SPACES.

5. TAKE EVERY PRECAUTION TO MINIMIZE DISRUPTION WITH ADJACENT OCCUPIED SCHEDULE AND SEQUENCING OF WORK TO BE COORDINATED WITH VAMC COR PRIOR TO BEGINNING WORK, AND MODIFIED

AS NEEDED DEPENDENT ON PATIENT COMFORT AND TREATMENT.

6. PATCH ALL SURFACES TO REMAIN EFFECTED BY DEMOLITION OR REMOVAL OF EXISTING EQUIPMENT & CONSTRUCTION. NEW SURFACES TO BE FILLED, SANDED SMOOTH & FINISHED TO MATCH ADJACENT

SURFACE.

7. MAINTAIN EXISTING UTILITIES INDICATED TO REMAIN, KEEP IN SERVICE, AND PROTECT AGAINST DAMAGE DURING ALL RENOVATION WORK. COORDINATE CONSTRUCTION AROUND EXISTING EQUIPMENT, CONDUIT

CABLING, ETC. WITH COR AS REQUIRED TO MAINTAIN CONTINUOUS OPERATION.

8. COMPLY WITH GOVERNING REGULATIONS PERTAINING TO ENVIRONMENTAL PROTECTION FOR POLLUTION

CONTROL & HAZARDOUS MATERIALS.

9. ALL EXISTING OR NEW PENETRATIONS IN RATED ASSEMBLIES SHALL BE SEALED WITH UL/FM APPROVED

MATERIAL ASSEMBLIES AND PROCEDURES.

10. ALL DIMENSIONS ARE FROM FINISH FACE OF WALL TO FINISH FACE OF WALL.

11. DRAWINGS SHALL NOT BE SCALED AS A BASIS FOR ESTABLISHING DIMENSIONS OR OTHER INFORMATION.

12. ANY DAMAGES AS A RESULT FROM CONSTRUCTION WILL BE REPAIRED BY GC. EXAMPLE WATER DAMAGES DUE TO RAIN ALL ARES THAT ARE EXPOSED WILL BE THE RESPOSIBILITY OF THE GC. TO PROTECT AREAS

BELOW ROOFING.

A-101

A-101

A-101

A-101

A-101

A-101

A-101

A-101

A-101

A-101

ROOF TO WALL BASE FLASHING

SCALE: 1-1/2" = 1'-0"5

A-101

A-101

A-501

A-101

4 4 4

ELECTRICAL POWER PLAN KEYED NOTES:

PROVIDE LIGHTNING PROTECTION FOR NEW EQUIPMENT, CONNECT TO EXISTING

LIGHTNING PROTECTION CABLE LOOP AT ROOF PERIMETER. SEE DETAILS ON A-501.2-1

2-1

2-1

2-1

2-1

A-101

A-101

A-101

A-101

BUILT UP

EPDM FOR

SPLASH

44' LF

5' LF

21' LF

26' LF

25' LF

10' LF

14' LF

14' LF

46' LF

13' LF

15' LF

11' LF

40' LF REGLET

' L

F R

EG

LE

T

11'LF

REGLET

20'LF

REGLET

19'LF

REGLET

AutoCAD SHX Text 19.1

AutoCAD SHX Text

T.O. EXIST CONC. EXIST CONC. PLANK @ 11'-4"

AutoCAD SHX Text

SLOPE TO DRAIN

AutoCAD SHX Text

P.T. WOOD WOOD BLOCKING

AutoCAD SHX Text

CONT. BENT PLATE 5/16X5 1/2X6 LLH WELD TO BEAM

AutoCAD SHX Text

5 1/2" CONCRETE SLAB

AutoCAD SHX Text

CONC. PLANKS ROOF

AutoCAD SHX Text

5 "CONC. ROOF 12"CONC. ROOF ON METAL DECK

ROOF TO WALL & METAL PANELS DETAIL

2"

MIN

8" MIN

EXISTYING DOWN SPOUT

CARRY TO DRAIN

PROVIDE NEW EPDM

WITH TAPPERED INSULATION

PROVIDE NEW CANT WITH

INSULATION

PROVIDE ADDITION 1'-0"x 4'-0"

STRIP OF EPDM FROM UNDER

DOWN SPOUT TO DRAIN.

2'-0" MIN.

2'-0" MIN.

on e ei gh th in ch o ne fo ot

B

A

C

D

E

F th re e in ch es o ne fo ot 6"

6" on e an d on e ha lf in ch es o ne fo ot on e in ch o ne fo ot

6" 6" th re e qu ar te rs in ch o ne fo ot on e ha lf in ch o ne fo ot th re e ei gh th s in ch o ne fo ot on e qu ar te r i nc h on e fo ot

VA FORM 08-6231

1 2 3 4 5 6 87 9

97 8654321

DRAWING TITLE PROJECT TITLE

LOCATION

DATE CHECKED DRAWN

DRAWING NUMBER

BUILDING NUMBER

PROJECT NUMBER

REVISION DATE

SYRACUSE

VA MEDICAL

CENTER

ENGINEERING

DEPARTMENT

800 IRVING AVE. SYRACUSE, NY 13210

03/31/2023

GENERAL PROJECT INFORMATION

100% SPRINKLERED

DWG.

U.S. Department of Veterans Affairs

B

A

C

D

E

F

528A7-23-105REPLACE ROOF 43

100% DRAWING DOC 06 OF 06

A-501

KWDW

ARCHITECTURAL ROOF DETAILS &

SCHEDULES

EPDM OUTSIDE CORNER

FLASHING DETAIL

SCALE: 3" = 1'-0"9

EPDM INSIDE CORNER

FLASHING DETAIL

SCALE: 3" = 1'-0"8

EPDM SPLICE INTERSECTION DETAIL

SCALE: 1:14

TYPICAL WALKWAY OR

EQUIPMENT SUPPORT PAD DETAIL

SCALE: 3" = 1'-0"7

EQUIPMENT CURB FLASHING DETAIL

SCALE: 1 1/2" = 1' -0"11

ROOF FLASHING TO

METAL SIDING DETAIL

SCALE: 1:15

EPDM ROOF EQUIPMENT WOOD SLEEPER DETAIL

SCALE: 1:110

ROOF DRAIN IN EPDM ROOF

WITH COMPOSITE DECK DETAIL

SCALE: 1:13

PIPE PENETRATION THRU EPDM ROOF DETAIL

SCALE: NONE2

EQUIPMENT BASE FLASHING DETAIL

SCALE: 1 1/2" = 1' -0"6

LARGE DIAMETER PIPE PENETRATION DETAIL

SCALE: 1 1/2" = 1' -0"14

PIPE PENETRATION THRU EPDM ROOF DETAIL

SCALE: NONE1

CANOPY ROOF DETAIL

SCALE: 1-1/2" = 1'-0"15

LIGHTNING ARRESTOR SYSTEM

ROOF LEVEL BONDING DETAILS

SCALE: NONE16

AutoCAD SHX Text

PRESSURE-SENSITIVE FLASHING & EPDM PRIMER

AutoCAD SHX Text

EPDM MEMBRANE; FULLY ADHERED

AutoCAD SHX Text

CONTINUOUS EPDM FLASHING; FULLY ADHERED

AutoCAD SHX Text NOTE: EPDM PRIMER MUST BE APPLIED TO ALL SPLICE AREAS AND FOR EACH LAYER OF PRESSURE-SENSETIVE FLASHING.

AutoCAD SHX Text

PRESSURE-SENSITIVE FLASHING AND EPDM PRIMER

AutoCAD SHX Text

CONTINUOUS EPDM FLASHING; FULLY ADHERED

AutoCAD SHX Text

EPDM MEMBRANE; FULLY ADHERED

AutoCAD SHX Text NOTE: EPDM PRIMER MUST BE APPLIED TO ALL SPLICE AREAS AND FOR EACH LAYER OF PRESSURE-SENSETIVE FLASHING.

AutoCAD SHX Text

PRESSURE SENSITIVE T-JOINT COVER

AutoCAD SHX Text

TAPE OVERLAP

AutoCAD SHX Text

EPDM PRIMER

AutoCAD SHX Text

TAPE

AutoCAD SHX Text NOTES: 1. FIELD APPLIED TAPE IS TO BE OVERLAPPED A MINIMUM OF 1" AT THE ENDS OF EACH CUT PIECE. FIELD APPLIED TAPE IS TO BE OVERLAPPED A MINIMUM OF 1" AT THE ENDS OF EACH CUT PIECE. APPLY LAP SEALANT AT TAPE OVERLAPS 2" IN ALL DIRECTIONS AS SHOWN. 2. APPLY LAP SEALANT ALONG THE LEADING EDGE OF THE MEMBRANE SPLICE UNDER THE 6" X 6" APPLY LAP SEALANT ALONG THE LEADING EDGE OF THE MEMBRANE SPLICE UNDER THE 6" X 6" T-JOINT COVER, COVERING THE EXPOSED SPLICE TAPE 2" IN ALL DIRECTIONS FROM THE SPLICE INTERSECTION. 3. 6" WIDE PRESSURE-SENSITIVE FLASHING IN CONJUNCTION WITH EPDM PRIMER, MAY ALSO BE 6" WIDE PRESSURE-SENSITIVE FLASHING IN CONJUNCTION WITH EPDM PRIMER, MAY ALSO BE CENTERED OVER THE INTERSECTING POINT OF THE LEADING EDGES OF THE FIELD SPLICE INTERSECTION. 4. LAP SEALANT IS REQUIRED ON CUT EDGES OF REINFORCED EPDM MEMBRANE.LAP SEALANT IS REQUIRED ON CUT EDGES OF REINFORCED EPDM MEMBRANE.

AutoCAD SHX Text

EXIST CONC OR METAL DECK

AutoCAD SHX Text

PITCH VARIES

AutoCAD SHX Text EPDM WALKWAY/EQUIPMENT PAD SET W/3 ROWS OF 3" SPLICE TAPE OR AS PER MFR INSTRUCTIONS; SPACE PADS MIN 2" APART

AutoCAD SHX Text

EPDM MEMBRANE FULLY ADHERED WITH BONDING ADHESIVE

AutoCAD SHX Text

12" COVERBOARD COVERBOARD

AutoCAD SHX Text

TAPERED RIGID INSUL RIGID INSUL (DEPTH VARIES)DEPTH VARIES))

AutoCAD SHX Text

VAPOR RETARDER

AutoCAD SHX Text

TAPERED RIGID INSULATION ATION (TOTAL R-30)30))

AutoCAD SHX Text

PRE-MOLDED EPDM PIPE FLASHING

AutoCAD SHX Text

EXISTING 3" PIPE

AutoCAD SHX Text

3" SEAM TAPE

AutoCAD SHX Text

FULLY ADHERED EPDM MEMBRANE

AutoCAD SHX Text

CLAMPING RING

AutoCAD SHX Text

CONT SEALANT

AutoCAD SHX Text

12" COVERBOARD

AutoCAD SHX Text

EXIST DECK & STRUCTURE

AutoCAD SHX Text

SINGLE PLY EPDM MEMBRANE

AutoCAD SHX Text

VAPOR RETARDERAPOR RETARDERRETARDERETARDER

AutoCAD SHX Text

EXIST PIPE OR CONDUIT (UP TO 6" )

AutoCAD SHX Text

CONTINUOUS BEAD OF LAP SEALANT

AutoCAD SHX Text

CLAMPING RING

AutoCAD SHX Text

EXIST PIPE OR CONDUIT (UP TO 6" )

AutoCAD SHX Text

CONTINUOUS BEAD OF LAP SEALANT

AutoCAD SHX Text

9" FORMABLE FLASHING SET IN MASTIC

AutoCAD SHX Text

5" SEAM FLASHING

AutoCAD SHX Text

EPDM MEMBRANE FULLY ADHERED WITH BONDING ADHESIVE

AutoCAD SHX Text

12" COVERBOARD COVERBOARD

AutoCAD SHX Text

RIGID INSULATION ATION (TOTAL R-30)30))

AutoCAD SHX Text

TAPERED RIGID INSUL RIGID INSUL (DEPTH VARIES)DEPTH VARIES))

AutoCAD SHX Text

VAPOR RETARDER

AutoCAD SHX Text

EXIST CONC. DECKCONC. DECK

AutoCAD SHX Text

OF DRAIN

AutoCAD SHX Text

*NOTE: SEE MANUFACTURER'S INSTALLATION INSTRUCTIONS FOR ADDITIONAL INFORMATION

AutoCAD SHX Text

STRAINER BASKET

AutoCAD SHX Text EXTEND EPDM BEYOND CLAMPING RING A MIN OF `8"; FINAL HOLE `8"; FINAL HOLE "; FINAL HOLE SHOULD NOT BE SMALLER THAN THE DIAMETER OF THE EXIST LEADER PIPE

AutoCAD SHX Text

EPDM MEMBRANE FULLY ADHERED WITH BONDING ADHESIVE

AutoCAD SHX Text

12" COVERBOARD

AutoCAD SHX Text

TAPERED RIGID INSULATION (TOTAL R-30)

AutoCAD SHX Text

EPDM MEMBRANE SET IN CONTINUOUS BED OF WATERBLOCK SEALANT

AutoCAD SHX Text

VAPOR RETARDER

AutoCAD SHX Text EXIST ROOF DRAIN LEADER PIPE; MODIFY AS REQ'D TO MATCH NEW ROOF DRAIN & ROOF ELEV. COORDINATE W/VAMC COR

AutoCAD SHX Text 1'-6"

AutoCAD SHX Text 1'-6"

AutoCAD SHX Text

NEW ROOF DRAIN ASSEMBLY; SEE SPECS

AutoCAD SHX Text

SUMP PITCH: MIN. 1" PER FOOT

AutoCAD SHX Text

UNDER DECK CLAMP

AutoCAD SHX Text

EXIST. CONCRETE DECK

AutoCAD SHX Text

ROOF DRAIN COMPRESSION RING

AutoCAD SHX Text

EXIST OPENING IN ROOF STRUCTURE (VIF)

AutoCAD SHX Text

EPDM MEMBRANE FULLY ADHERED

AutoCAD SHX Text

EPDM EQUIPMENT PAD

AutoCAD SHX Text EXIST DIMENSIONAL WOOD EQUIPMENT SLEEPER TO BE REPLACED W/ LIKE SIZE NEW WOOD SLEEPER

AutoCAD SHX Text

TAPERED INSUL (DEPTH VARIES)

AutoCAD SHX Text

`8" SUBSTRATE BOARD" SUBSTRATE BOARD

AutoCAD SHX Text

EXIST CONC DECK & STRUCTURE

AutoCAD SHX Text

VAPOR RETARDERAPOR RETARDERRETARDERETARDER

AutoCAD SHX Text EXIST ROOF MOUNTED EQUIPMENT TO BE LIFTED FOR REPLACEMENT OF OLD WOOD SLEEPERS, RE-SECURE TO NEW SLEEPERS

AutoCAD SHX Text

NEW METAL FLASHING CAP SET IN WATERBLOCK SEALANT

AutoCAD SHX Text WRAP EPDM OVER NEW WOOD SLEEPER; COMPLETELY COVER WOOD & EXTEND ONTO DECK AS SHOWN, SEAL ALL EDGES

AutoCAD SHX Text

TAPERED RIGID INSULATION INSULATION ATION (TOTAL R-30)30))

AutoCAD SHX Text

EPDM MEMBRANE SET IN ADHESIVE, EXTEND DN ONTO ROOF AS INDICATED

AutoCAD SHX Text BATTEN STRIP SECURED @ 12" O.C. MAX. APPLY O.C. MAX. APPLY O.C. MAX. APPLY .C. MAX. APPLY C. MAX. APPLY . MAX. APPLY MAX. APPLY SEALANT OVER FASTENERSEALANT OVER FASTENERSLANT OVER FASTENERSANT OVER FASTENERSNT OVER FASTENERS

AutoCAD SHX Text

EXIST METAL SIDING PANEL (NIC)

AutoCAD SHX Text

EXIST METAL SIDING BASE FLASHING (NIC)

AutoCAD SHX Text

EPDM ROOFING MEMBRANE; EXTEND UP WALL SET IN MASTIC

AutoCAD SHX Text

EXIST WOOD BLOCKING (NIC)

AutoCAD SHX Text

EXIST WALL STRUCTURE & SHEATHING

AutoCAD SHX Text

EXIST CANT TO REMAIN

AutoCAD SHX Text

EXIST ROOF DECK

AutoCAD SHX Text

CONT SEALANT BEAD

AutoCAD SHX Text

FOR ITEMS NOT NOTED SEE DETAILS ON THIS SHEET FOR CLARIFICATION

AutoCAD SHX Text

`8" COVERBOARD" COVERBOARD

AutoCAD SHX Text

EXIST CONC DECK & STRUCTURE

AutoCAD SHX Text

SINGLE PLY EPDM MEMBRANE (FULLY ADHERED)

AutoCAD SHX Text

VR

AutoCAD SHX Text

3" SEAM SPLICE TAPE

AutoCAD SHX Text

BATTEN STRIP SECURED @ 12"OC MAX. APPLY SLNT OVER FASTENERS

AutoCAD SHX Text

EXIST WD CURB

AutoCAD SHX Text

EXIST DUCT & BLOWER W/ INTEGRATED FLASHING. VERIFY CONDITION & REUSE

AutoCAD SHX Text

TAPERED RIGID INSULATION INSULATION ATION (TOTAL R-30)30))

AutoCAD SHX Text

2X2 WD BLOCKING

AutoCAD SHX Text

EXIST EQUIPMENT CURB

AutoCAD SHX Text

BATTEN STRIP SECURED @ 12"OC MAX. APPLY SLNT OVER FASTENERS

AutoCAD SHX Text

SINGLE PLY EPDM MEMBRANE SET IN BONDING ADHESIVE

AutoCAD SHX Text

3" SEAM SPLICE TAPE

AutoCAD SHX Text

SINGLE PLY EPDM MEMBRANE FULLY ADHERED

AutoCAD SHX Text

CONTINUOUS BD SLNT

AutoCAD SHX Text

2X4 WD BLOCKING

AutoCAD SHX Text

EXIST EQUIPMENT MOUNTED FLASHING - VERIFY CONDITION & REUSE

AutoCAD SHX Text

EXIST SLNT REMOVE & REPLACE

AutoCAD SHX Text

2X12 WD BLOCKING

AutoCAD SHX Text

FOR ITEMS NOT NOTED SEE DETAIL 8E/A500

AutoCAD SHX Text

EXIST CONC DECK

AutoCAD SHX Text

EXIST AIR HANDLING UNIT

AutoCAD SHX Text

`8" COVERBOARD" COVERBOARD

AutoCAD SHX Text

TAPERED INSULATION NSULATION ATION (TOTAL R-30)30))

AutoCAD SHX Text

VR

AutoCAD SHX Text

EXIST CONC DECK & STRUCTURE

AutoCAD SHX Text

LARGE DIAMETER ROUND PENETRATION (GREATER THAN 6"`&)`&))

AutoCAD SHX Text

PITCH PER FOOT "14"

AutoCAD SHX Text

PREFORMED EPDM FLASHING

AutoCAD SHX Text

CONTINUOUS SLANT

AutoCAD SHX Text

SINGLE PLY EPDM MEMBRANE

AutoCAD SHX Text

CONTINUOUS SLANT

AutoCAD SHX Text LIGHTNING ARRESTOR SYSTEM NOTES: 1. THESE DETAILS ARE SHOWN FOR REFERENCE IF MODIFICATIONS ARE REQUIRED TO EXISTING LIGHTNING PROTECTION SYSTEMS THESE DETAILS ARE SHOWN FOR REFERENCE IF MODIFICATIONS ARE REQUIRED TO EXISTING LIGHTNING PROTECTION SYSTEMS AFFECTED BY THE SCOPE OF WORK FOR THIS PROJECT. 2. AIR TERMINALS SHALL EXTEND NO LESS THAN 24 INCHES ABOVE THE ROOF PARAPET. AIR TERMINALS SHALL EXTEND NO LESS THAN 24 INCHES ABOVE THE ROOF PARAPET. 3. ALL METAL EQUIPMENT ON THE ROOF SHALL BE BONDED TO THE LIGHTNING PROTECTION SYSTEM. ALL METAL EQUIPMENT ON THE ROOF SHALL BE BONDED TO THE LIGHTNING PROTECTION SYSTEM. 4. USE NICKEL PLATED CONNECTORS AND FITTINGS FOR SURFACES NOT COMPATIBLE WITH COPPER. USE NICKEL PLATED CONNECTORS AND FITTINGS FOR SURFACES NOT COMPATIBLE WITH COPPER. 5. THRU-ROOF FLASHING SHALL BE COPPER WITH 8 INCH ROUND BASE AND VERTICAL TUBE WITH NEOPRENE SEAL. FLASHING SHALL THRU-ROOF FLASHING SHALL BE COPPER WITH 8 INCH ROUND BASE AND VERTICAL TUBE WITH NEOPRENE SEAL. FLASHING SHALL BE THE PRODUCT OF THE MANUFACTURER OF THE LIGHTNING PROTECTION SYSTEM. MEMBRANE FLASHING SHALL BE PROVIDED OVER THE THRU-ROOF FLASHING.

AutoCAD SHX Text

CLIP CABLE SUPPORT

AutoCAD SHX Text

HORIZONTAL AIR TERMINAL INSTALLATION

AutoCAD SHX Text

AIR TERMINAL INSTALLATION

AutoCAD SHX Text

CAST BRONZE 8" SQ. BONDING PLATE

AutoCAD SHX Text

FASTEN PLATE TO CLEANED BARE METAL SURFACE W/(2) SELF-TAPPING SST SCREWS

AutoCAD SHX Text

LIGHTNING PROTECTION CONDUCTOR CABLE

AutoCAD SHX Text

STRUCTURAL BONDING

AutoCAD SHX Text

EQUIPMENT BONDING

AutoCAD SHX Text

SECONDARY BONDING

AutoCAD SHX Text

LIGHTNING PROTECTION CONDUCTOR CABLE

AutoCAD SHX Text CAST BRONZE 3" SQ. BONDING PLATE; FASTEN PLATE TO CLEANED BARE METAL SURFACE W/(2) SELF-TAPPING SST SCREWS

AutoCAD SHX Text

LIGHTNING PROTECTION CONDUCTOR CABLE

AutoCAD SHX Text

CAST BRONZE SECONDARY CABLE SPLICER

AutoCAD SHX Text

COPPER SECONDARY BONDING WIRE

AutoCAD SHX Text

CAST BRONZE SECONDARY BONDING LUG

AutoCAD SHX Text

SEALING WASHER

AutoCAD SHX Text

MAIN CONDUCTOR

AutoCAD SHX Text

CLIP CABLE SUPPORT

AutoCAD SHX Text

AIR TERMINAL

AutoCAD SHX Text

PARAPET WALL

AutoCAD SHX Text

CABLE CONNECTOR

AutoCAD SHX Text

AIR TERMINAL

AutoCAD SHX Text

MAIN CONDUCTOR

AutoCAD SHX Text

PIPE BONDING

AutoCAD SHX Text

LIGHTNING PROTECTION CONDUCTOR CABLE

AutoCAD SHX Text

COPPER PIPE-BONDING STRAP

AutoCAD SHX Text

CAST BRONZE CABLE SPLICER

Sheets and Views
528A7-23-105-GI-001
528A7-23-105-GC-101
528A7-23-105-A-001
528A7-23-105-AD-101
528A7-23-105-A-101
528A7-23-105-A-501

File details come from the government source that posted it. Updated .