The file's text, extracted by GovTribe without its formatting.
STATEMENT OF WORK
SECURITY SYSTEM AND EQUIPMENT MAINTENANCE, REPAIR, AND REPLACEMENT SERVICES
LOWER RIO GRANDE VALLEY (LRGV) FACILITIES – MERCEDES FIELD OFFICE, ANZALDUAS DAM, AND RETAMAL DAM
1. GENERAL
The United States Section of the International Boundary and Water Commission (USIBWC) is responsible for applying boundary and water treaties between the United States and Mexico and resolving issues arising from their application. The USIBWC is a federal agency headquartered in El Paso, Texas, with field offices throughout the region. The Mercedes Field Office is responsible for the operations and maintenance of levee systems and flood control operations in the Lower Rio Grande Valley (LRGV), including the Anzalduas and Retamal Dams.
2. SCOPE OF WORK
The Contractor shall provide all labor, materials, equipment, tools, transportation, supervision, software support, licensing, and expertise necessary to perform maintenance, repair, and like-for-like replacement of security system components at the Mercedes Field Office, Anzalduas Dam, and Retamal Dam.
Supported systems include, but are not limited to: Physical Access Control Systems (PACS), Closed-Circuit Television (CCTV), Network Video Recorders (NVR), communication equipment, Intrusion Detection Systems (IDS), CCURE 9000 Security Management System (SMS), and all associated hardware, software, and integrations.
The Contractor shall:
- Maintain, troubleshoot, repair, and replace failed components with compatible like-for-like replacements.
- Ensure CCURE 9000 software and related integrations are updated to current vendor-supported release levels.
- Maintain all required licenses with no interruptions to functionality.
- Provide loaner equipment where necessary to maintain operational continuity.
- Perform annual inspections when requested by the Security Services Division (SSD) and provide a written inspection report.
- Coordinate with SSD to perform annual site surveys to identify preventative maintenance requirements.
- Maintain IDS monitoring functionality without service interruption.
- Respond on-site within eight (8) hours of notification unless otherwise authorized; remote troubleshooting may be performed when appropriate.
The Contractor shall not be responsible for damage resulting from events outside its control (e.g., vandalism, natural disasters); however, repair services may be required under this SOW.
3. PLACE OF PERFORMANCE
Security systems covered under this SOW are located at the following LRGV facilities:
Mercedes Field Office 325 Golf Course Rd.
Mercedes, Texas 78570
Anzalduas Dam Anzalduas Dam Road Mission, Texas 78572
Retamal Dam Approximately 16 miles southeast of McAllen, Texas
Facility hours are Monday through Friday, 7:00 a.m. to 5:00 p.m. (CT), excluding federal holidays. Retamal Dam is unmanned and will require coordination for access.
4. REQUESTING REPAIRS
The SSD will contact the Contractor when services are required. Services may include inspections, troubleshooting, repairs, replacements, software updates or upgrades, system adjustments, battery replacements, and other tasks necessary to ensure full operational functionality.
The Contractor shall be available 24/7 and capable of on-site response within eight (8) hours of notification. Remote or telephonic troubleshooting may occur prior to dispatch if appropriate.
5. EQUIPMENT LIST
Major components of the security systems include, but are not limited to, the following equipment categories and representative models:
- Firewalls, access cards, sirens, strobe lights, push-to-exit switches, cabling, electric strikes, emergency door release devices, sensors, intrusion panels and keypads, network switches, CCTV cameras, NVRs, mounts, software licenses, UPS systems, power distribution modules, and associated connectors and accessories.
- All replacements must be compatible with CCURE 9000, American Dynamics Victor, DSC NEO, and related integrations.
A detailed listing of equipment is maintained by SSD and is subject to update. The Contractor shall verify all components on-site as part of service planning and execution.
6. SOFTWARE, LICENSING, AND CYBER REQUIREMENTS
The Contractor shall:
- Maintain all software and firmware at supported versions, including CCURE 9000 and Victor integrations.
- Apply security patches within thirty (30) days of vendor release unless otherwise directed by SSD.
- Comply with cybersecurity-related federal prohibitions, including restrictions on covered foreign technologies.
7. PERSONNEL AND ACCESS REQUIREMENTS
All Contractor personnel accessing secured facilities must be U.S. persons, carry government-issued badges when required, and comply with applicable Personal Identity Verification (PIV) procedures.
Scheduling and escort procedures shall be coordinated with SSD and site personnel.
8. QUALITY CONTROL
The Contractor shall maintain a Quality Control (QC) Plan that addresses preventive maintenance schedules, troubleshooting procedures, documentation standards, and configuration/change management. QC documentation shall be provided to the Contracting Officer (CO) or COR upon request.
9. SERVICE CONTRACT LABOR STANDARDS
This requirement is subject to the Service Contract Labor Standards (SCLS). The applicable Wage Determination is provided in the solicitation package.
10. DELIVERABLES
The Contractor shall provide the following deliverables:
1. Annual Inspection and Service Report documenting asset conditions, deficiencies, patch and version status, and recommendations.
2. Troubleshooting and Repair Log submitted upon request.
3. Updated License Inventory provided annually or upon request.
4. Quality Control Plan, initial submission within 30 days of award and updated annually.
11. Government Furnished Information and Access The Government will provide necessary site access, scheduling information, and any available configuration documentation required to perform the work.
| ITEM # |
| MANUFACTURER |
| MODEL |
| COMPONENT |
| 1 |
| SonicWall |
| 01-SSC-0575 |
| FIREWALL APPLIANCE, SERIES TZ300 |
| 2 |
| HID |
| 1326LSSMV |
| PROXCARD II, 125 KHZ, ACCESS CARD |
| 4 |
| Amseco |
| 4150026 |
| SIRENW/BLUE STROBE,15 WATT |
| 5 |
| SDC |
| 423PU |
| EXIT SWITCH,2 INCH, PUSH TO EXIT BUTTON GRN II |
| 6 |
| Windy City Wire |
| 442360 |
| CABLE,18-20, UNS, PLENUM WHITE , STRD |
| 7 |
| Windy City Wire |
| 444351-03S |
| 22-6C PLENUM,CSPL,STR,SHLD |
| 8 |
| Windy City Wire |
| 444366GW |
| 22-2 UNSHLD,STRD PLENUM, WHT/GRN |
| 9 |
| Windy City Wire |
| 444381 |
| 22G-4C PLENUM, STR, NON-SHLD |
| 10 |
| Windy City Wire |
| 446111WBT-S-671 |
| CABLE, COMPOSITE 4 ELEMENT , 23-4P, OAS+2204 |
| 11 |
| Assa Abloy |
| 4500C-630 |
| ELECTRIC STRIKE |
| 12 |
| SDC |
| 491 |
| BREAK GLASS STATION, BLUE, EMER. DOOR RELEASE |
| 13 |
| SDC |
| 491-BB |
| OPTION, SURFACE BOX FOR EMER. DOOR RELEASE |
| 14 |
| SDC |
| 491-GL4 |
| OPTION, 4 EACH REPL. GLASS FOR EMER. DOOR |
| 15 |
| Assa Abloy |
| 70-628 |
| PUSH CVR PLATE, BRUSHED ALUMINUM, 3 X 15 |
| 16 |
| Windy City Wire |
| 727310VNQ |
| 18-04 CABLE, UNSHLD, STRD, VNTC, DIRECT BURIAL |
| 17 |
| Windy City Wire |
| 775600-110DB |
| CAT6, DIRECT BURIAL |
| 18 |
| Logitech |
| 920-007897 |
| MK270 WIRELESS KEYBOARD AND MOUSE |
| 19 |
| HID |
| 920PHRNEK00004 |
| CARD READER, RP40-H, PIV CLASS |
| 20 |
| Acuity |
| AC-102 |
| GLASSBREAK SENSOR |
| 21 |
| Altronix |
| ACM8 |
| ACCESS POWER CONTROLLER, 8 FUSED RELAY OUTPUTS |
| 22 |
| American Dynamics |
| ADCDMCRNRO |
| MOUNT, ADAPTER, OUTSIDE CORNER |
| 23 |
| American Dynamics |
| ADCDMPOLE |
| MOUNT, ADAPTER, POLE |
| 24 |
| American Dynamics |
| ADCH10HBMT8 |
| CAM HOUSING, 9.5 MAX CAMERA LENGTH, IN/OUTDOOR |
| 25 |
| American Dynamics |
| ADSL940A |
| VARIFOCAL LENS, THEIA 940 SERIES, DAY/NIGHT |
| 26 |
| American Dynamics |
| ADSPOT-251 |
| POWER SUPPLY FOR OPTIMA/ULTRA DOME |
| 27 |
| American Dynamics |
| ADVASC01 |
| VICTOR PRO, SINGLE CONCURRENT CLIENT CONN |
| 28 |
| American Dynamics |
| ADVC-CC9000 |
| UNIFIED CCURE 9000VICTOR LIC. AMER. DYN. |
| 29 |
| American Dynamics |
| ADVC-DSC |
| VICTOR INTEGRATION W/ INTRUSION DSC POWER |
| 30 |
| American Dynamics |
| ADVC-DSC-S |
| VICTOR INTEGRATION W/ INTRUSION DSC POWER |
| 31 |
| American Dynamics |
| ADVC-ITV2 |
| VICTOR INTEGRATION W/ DSC NEO ITV2 |
| 32 |
| American Dynamics |
| ADVC-ITV2-S |
| VICTOR INTEGRATION W / INTRUSION DSC NEO SSA |
| 33 |
| American Dynamics |
| ADVC-VCHEALTH |
| SOFTWARE, VICTOR PRO ADD ON CLIENT |
| 34 |
| American Dynamics |
| ADVC-VCMAP |
| VICTOR PRO, ADD-ON, VICTOR CLIENT MAPS |
| 35 |
| American Dynamics |
| ADVC-VCVMK |
| VICTOR PRO ADD-ON, VIRTUAL CLIENT |
| 36 |
| American Dynamics |
| ADVCPTZKEY1 |
| AMER. DYN. SURVEILLANCE KEYBOARD |
| 37 |
| American Dynamics |
| ADVEC01-ICF |
| FREE LIC. FOR AD CAMERAS |
| 38 |
| American Dynamics |
| ADVER12R5N2B |
| VIDEO EDGE 2U NVR, 4 IP CAMERA LIC , 12TB RAID |
| 39 |
| American Dynamics |
| ADVESSAS |
| SOFTWARE SUPPORT AGREE, NVR SERVER |
| 40 |
| American Dynamics |
| ADVS1SSA |
| SSA VICTOR / CONCURRENT CLIENT LIC.-1YR |
| 41 |
| American Dynamics |
| ADVSMC01ADD |
| SOFTWARE, SITE MANAGER, VICTOR 4.2 SERIES (1) |
| 42 |
| DSC |
| AFT-100 |
| GLASSBREAK SIMULATOR |
| 43 |
| Software House |
| AS0073-000 |
| I8 EIGHT INPUT RDR BUS MODULE |
| 44 |
| Software House |
| AS0074-000 |
| R8 EIGHT OUTPUT RDR BUS MODULE |
| 45 |
| Para Systems |
| BP48RTXL |
| BATTERY PACK, EXT. FOR ENDEAVOR 1-3KVA |
| 46 |
| DSC |
| HS2128NKCP01 |
| INTRUSION PANEL |
| 47 |
| DSC |
| HS2LCDENG |
| INTRUSION KEYPAD |
| 48 |
| DSC |
| HSM2108 |
| ZONE EXPANDER |
| 49 |
| DSC |
| HSM2204 |
| OUTPUT MODULE |
| 50 |
| USP |
| HUB-2SA |
| MOMENTARY HOLD UP BUTTON SPDT |
| 51 |
| Illustra |
| IFS03XNANWTT |
| BOX CAMERA, 3MP NO LENS |
| 52 |
| Securitron |
| IMXDA |
| MAGLOCK, INTEGRATED MOTION, DUAL |
| 53 |
| Illustra |
| IPL02B1BNWIY |
| BULLET CAM, 2.8-12MM LENS, IR, WDR, POE, 2MP |
| 54 |
| Illustra |
| IPLB-MPOLE |
| POLE MOUNT ADAPTER |
| 55 |
| Illustra |
| IPS02P6OCWTT |
| PTZ NETWORK CAMERA, TRUE DAY/NIGHT |
| 56 |
| Kaspersky Lab |
| KL4863ACPTS |
| ANTI VIRUS SOFTWARE |
| 57 |
| DSC |
| LC-100-PI |
| INDOOR MOTION DETECTOR |
| 58 |
| Startech |
| M45PATCH5BL |
| PATCH CABLE, CAT5E,5 FEET , BLUE |
| 59 |
| Altronix |
| MAXIMAL75E |
| POWER SUPPLY / CHARGERS(2), 1 IS 12VDC |
| 60 |
| Schlage |
| ND96PDRHO626C |
| CYLINDRICAL MECHANICAL LOCK |
| 61 |
| Software House |
| CC9000-KIT |
| C-CURE 9000 SOFTWARE, QUICK START DVD |
| 62 |
| Software House |
| CC9000-SL |
| C-CURE 9000 SERIES L SYSTEM LIC. ONLY |
| 63 |
| Middle Atlantic Products |
| CWR-12-32PD |
| DATA WAL CABINET |
| 64 |
| Bosch |
| DS160 |
| REQUEST TO EXIT, PIR MOTION SENSOR (REX) |
| 65 |
| Ditek |
| DTK-MRJPOE |
| SURGE PROTECTOR, POE |
| 66 |
| Elo Touch |
| E107766 |
| 2201L 22" LED LCD TOUCHSCREEN MONITOR |
| 67 |
| Para Systems |
| ED1000RTXL2U |
| MINUTEMAN UPS |
| 68 |
| iSTAR |
| ESTAR002-POE1 |
| ISTAR EDGE W/ ENCLOSURE AND POE |
| 69 |
| Digi-Key |
| EZ-RJ45(CAT6) |
| RJ45 CONNECTOR, 100 PER BAG |
| 70 |
| StarTech |
| HDMIDVIMM10 |
| 10FT HDMI TO DVID CABLE M-M |
| 71 |
| Magnasphere |
| HS-1270 |
| SPACERS FOR HS-L1.5 |
| 72 |
| Magnasphere |
| HS-1271 |
| OVERHEAD DR RAIL MNT BRKT FOR HS-L1.5 |
| 73 |
| Magnasphere |
| HS-1616 |
| L. BRACKET KIT FOR HS-L1.5 |
| 74 |
| Magnasphere |
| HS-L1.5-111 |
| HIGH SECURITY CONTACT, LEVEL 1 |
| 75 |
| DSC |
| PC4002C |
| EMPTY CABINET FOR 2 MODULES |
| 76 |
| Altronix |
| PD16WCB |
| POWER DISTRIBUTION MODULE ,16 OUTPUT |
| 77 |
| Altronix |
| PMK1 |
| POLE MOUNT FOR WP2 |
| 78 |
| Altronix |
| R248UL |
| POWER SUPPLY,24 VAC @3.5 AMP, 8 FUSE |
| 79 |
| RFIDeas |
| RFID-80081AKU |
| USB, WEDGE READER |
| 80 |
| Illustra |
| RHOSW-251 |
| WALL MNT FOR ULTRA AND OPTIMA OUTDOOR |
| 81 |
| Startech |
| RJ45COUPLER |
| NETWORK COUPLER |
| 82 |
| Software House |
| RM-DCM-CAN |
| ENCLOSURE FOR TWO RM-4E |
| 83 |
| Interlogix |
| S30-RJ |
| MINI GBIC RJ-45 |
| 84 |
| DSC |
| SD15W-ULF |
| 15W DUAL TONE SIREN |
| 85 |
| Seneca |
| SQ305785-CLIENT |
| CLIENT WORKSTATION, W10, 64 BIT, 8GB, CUSTOM |
| 86 |
| Seneca |
| SQ305785-SERVER |
| ACCESS CONTROL SERVER, VICTOR, CUSTOM |
| 87 |
| STI |
| STI-7081 |
| UNIVERSAL POLE MNT BRKT FOR CC |
| 88 |
| Marray |
| TEF2+4C US26D |
| STANDARD HINGE 4.5 X 4.5 |
| 89 |
| DSC |
| TL2803GREUSA |
| 3G WIRELESS COMM. |
| 90 |
| DSC |
| TL280RE |
| DSC NEO INTERNET ALARM COMMUNICATOR MODULE. |
| 91 |
| American Dynamics |
| U2 |
| RACKSHELF, 2 SPACE(3.5") |
| 92 |
| Windy City Wire |
| VEX-555619 |
| CABLE, CAT5, 24-4P, BLUE |
| 93 |
| Windy City Wire |
| VEX-556609 |
| CABLE, CAT6, 23-4P, BLUE |
| 94 |
| Anatel |
| WP2 |
| NEMA 4 ENCLOSURE |
ND96PDEUREX RHO626 24V IC
Schlage
ELECTRIFIED CYL. LOCK, STOREROOM
| 96 |
| Interlogix |
| NS3552-8P-2S |
| SWITCH, MANAGED, 8 PORT, INDUST. GIGABIT |
| 97 |
| Interlogix |
| NS3702-24P-4S |
| 24 PORT POE SWITCH |
| 98 |
| Altronix |
| AL1012ULACM |
| POWER SUPPLY |
| 99 |
| Seco-Larm |
| SD-969-S18 |
| ARMORED DOOR CORD |
| 100 |
| Power-Sonic |
| PS-1270-F1 |
| 12V 7A BATTERY |
| 101 |
| Assa Abloy |
| 7000C-630 |
| ELECTRIC STRIKE |
A80PDPLY626 11-
| Schlage |
| 099CKIT |
| DOOR LOCK, KEYED, PLYMOUTH KNOB, DEADLATCH |
| 103 |
| Amseco |
| 4190017 (SL-401) |
| BLUE STROBE |
| 104 |
| interlogix |
| 1078C-N |
| 3/4" WHITE RECESSED DOOR CONTACT |
| 105 |
| DMP |
| 322 |
| 16.5VAC TO 56VA TRANSFORMER |
| 106 |
| Assa Abloy |
| 1600-CLB-630 |
| ELECTRIC STRIKE |