1-Mt.Bethel Fire Company- Structural Unsealed.pdf
PDF 1 MB Posted
- Attached to
- Mt. Bethel Fire Co. - Emergency Shelter 2020-63
- Solicitation number
- Not on record
- Issued by
- Northampton County, Pennsylvania
About this file
This is a structural unsealed bid document for an addition to the Mt. Bethel Fire Company facility located at 2341 North Delaware Drive, Mt. Bethel, Pennsylvania 18343, in Upper Mount Bethel, Northampton County. The project involves the design and construction of approximately 2,000 square feet (20 feet by 100 feet) of new building space to provide emergency shelter capabilities during weather emergencies and community events. The addition will include handicapped-accessible toilet and shower facilities, conversion of an existing toilet room into a firefighters' shower room, an accessible entrance, and storage space for the social hall. The project also includes mechanical system upgrades for heating and air conditioning. A pre-bid meeting was scheduled for July 9, 2026, at 9:00 A.M. at the project site, with site viewing opportunities following the meeting. Bids were due on or before Tuesday, July 28, 2026, at 12:00 P.M. prevailing time. Contract documents became available online through the Penn Bid Program beginning July 2, 2026, at 4:00 P.M. at no cost.
The structural specifications require compliance with the 2021 International Building Code and include design parameters for a 40 PSF ground snow load, 115 MPH wind speed exposure (Category B), and Seismic Design Category B. All concrete work must achieve 3,000 PSI compressive strength, structural steel must meet ASTM specifications, and wood framing must conform to National Design Standards. Successful bidders must provide a Bid Bond and both Performance and Payment Bonds in the amount of 100 percent of the total contract value. The project is subject to all applicable Equal Employment Opportunity requirements for federally assisted and state-assisted contracts. The structural engineer of record is Base Engineering (bcohen@baseeng.com, 610-437-0978), the architect of record is Samantha Ciotti Falcone AIA, LEED AP, and the MEP engineer is Barry Isett & Associates (dhorsfield@barryisett.com, 610-437-0978).
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
STRUCTURAL
NOTES
S1.1
3515 Sunnyside Road Center Valley, PA 18034
T: 610-297-0140 E: sam@scf-arch.com These documents are instruments of the Architect's service for use solely with respect to this project.
The Architect shall retain all common law, statutory and other reserved rights, including the copyright.
They are not to be used for any purpose by any other party outside of the scope of this work without the specific written consent of the Architect.
L LC
STRUCTURAL ENGINEER OF RECORD:
101 NORTH QUEBEC STREET
ALLENTOWN, PA, 18109)
610-437-0978 bcohen@baseeng.com
M O
U N
T
BE
TH
EL
F
IR
E
CO
AD
DI
TI
O N
T O
E
XI
ST
IN
G
FI
RE
C
O M
PA
N
Y
N or th
D el aw ar e Dr iv e, M t.
Be th el , P
A
U pp er M ou nt
B et he l, N or th am pt on
C ou nt y
ARCHITECT OF RECORD:
Samantha Ciotti Falcone
AIA, LEED AP
DRAWN BY:
BID DOCUMENTS
6/23/2026
REV1
REV2
OWNER:
Mt. Bethel Fire Co.
ML, SCF
BARRY ISETT & ASSOCIATES
570-688-8268 dalehandelong@hotmail.com
MEP ENGINEER OF RECORD:
5420 Crackersport Rd Allentown, PA 18104
610-437-0978 EMAIL: dhorsfield@barryisett.com
BASE ENGINEERING
GENERAL NOTES
1. THE WORK SHOWN ON THESE DRAWINGS HAS BEEN DESIGNED IN ACCORDANCE WITH THE STRUCTURAL REQUIREMENTS OF THE 2021
INTERNATIONAL BUILDING CODE.
2.
3. THE STRUCTURAL COMPONENTS HAVE BEEN DESIGNED/ANALYZED FOR THE FOLLOWING LOADS:
ROOF: GROUND SNOW LOAD (Pg) OF 40 PSF MODIFIED IN ACCORDANCE WITH THE 2021 IBC, SECTION 1608
AND ASCE-7 05
MIN, ROOF SNOW LOAD: 30 PSF
DRIFTED SNOW: N/A
ROOF DEAD LOAD: 35 PSF
WIND LOADS: 115 MPH BASE DESIGN WIND SPEED), EXPOSURE B,
NET ROOF UPLIFT 0 PSF
EXPOSURE CATEGORY B
SEISMIC DESIGN CATEGORY B
SEISMIC SITE CLASS D
SEISMIC RISK CATEGORY II
MAPPED RESPONSE ACC (Ss) 0.2
MAPPED RESPONSE ACC (S1) 0.06
SPECTRAL RESPONSE COEF (Sds)0.21 SPECTRAL RESPONSE COEFF (Sd1) 0.096
SEISMIC FORCE RESISTING SYSTEM BEARING WALL SYSTEM
RESPONSE MODIFICATION FACTOR 2
DEFL AMPLIFICATION FACTOR 1.75
4. THE PORTIONS OF THE EXISTING STRUCTURE AFFECTED BY THIS WORK HAVE BEEN ANALYZED USING THE LOADS LISTED ABOVE AND FOUND TO BE CAPABLE OF SUPPORTING THE ADDITIONAL LOADS IMPOSED BY THIS WORK, EXCEPT WHERE STRENGTHENING WORK IS
INDICATED ON THE PLANS.
5. THIS STRUCTURE HAS BEEN DESIGNED TO BE SELF- SUPPORTING AND STABLE AFTER THE CONSTRUCTION OF THE BUILDING HAS BEEN COMPLETED. THE STABILITY OF THE STRUCTURE PRIOR TO COMPLETION IS SOLELY THE RESPONSIBILITY OF THE CONTRACTOR. THIS RESPONSIBILITY EXTENDS TO ALL RELATED ASPECTS OF THE CONSTRUCTION ACTIVITY INCLUDING, BUT NOT LIMITED TO, ERECTION METHODS, ERECTION SEQUENCE, TEMPORARY BRACING, FORMS, SHORING, USE OF EQUIPMENT, AND SIMILAR CONSTRUCTION PROCEDURES. REVIEW OF THE CONSTRUCTION BY THE ENGINEER IS FOR CONFORMANCE WITH DESIGN ASPECTS ONLY, NOT TO REVIEW THE CONTRACTOR'S CONSTRUCTION PROCEDURES. LACK OF COMMENT ON THE PART OF THE ENGINEER WITH REGARD TO CONSTRUCTION PROCEDURES IS NOT TO BE INTERPRETED AS APPROVAL OF THOSE PROCEDURES.
6. JOBSITE SAFETY IS SOLELY THE RESPONSIBILITY OF THE CONTRACTOR. REVIEW OF THE CONSTRUCTION BY THE ENGINEER IS FOR CONFORMANCE WITH DESIGN ASPECTS ONLY, NOT TO REVIEW THE CONTRACTOR'S PROVISIONS FOR JOBSITE SAFETY. LACK OF COMMENT ON THE PART OF THE ENGINEER WITH REGARD TO JOBSITE SAFETY IS NOT TO BE INTERPRETED AS APPROVAL OF JOBSITE
SAFETY ASPECTS.
7. THE CONTRACTOR IS RESPONSIBLE FOR PROVIDING ALL TEMPORARY BARRICADES OR BRIDGES IN CONFORMANCE WITH THE REQUIREMENTS SET FORTH BY THE LOCAL MUNICIPALITY(S), AND ANY ADDITIONAL FORMS OF PROTECTION AS REQUIRED TO PROTECT THE OWNER'S PERSONNEL AND THE GENERAL PUBLIC FROM INJURY DURING THE CONSTRUCTION PERIOD. DRIVEWAYS AND ENTRANCES SERVING THE PREMISES ARE TO BE KEPT CLEAR AND AVAILABLE TO THE OWNER, OWNER'S EMPLOYEES, AND GUESTS AT ALL
TIMES.
8. IF FAULTY CONSTRUCTION PROCEDURES, OR MATERIAL, RESULT IN DEFECTIVE WORK THAT REQUIRES ADDITIONAL ENGINEERING TIME TO DEVISE CORRECTIVE MEASURES, PROFESSIONAL FEES MAY BE CHARGED TO THE CONTRACTOR AT THE STANDARD HOURLY RATE OF
ADDITIONAL SERVICES. SUCH FEES MAY BE WITHHELD FROM THE CONTRACTOR'S PAYMENT.
SPECIAL NOTES TO THE CONTRACTOR:
1. THE CONTRACTOR SHALL FIELD VERIFY ALL DIMENSIONS AND ELEVATIONS OF THE EXISTING CONDITIONS BEFORE PROCEEDING WITH
ANY WORK.
2. THE CONTRACTOR SHALL REPORT TO THE ENGINEER ANY AND ALL CONDITIONS WHICH DIFFER FROM THOSE SHOWN ON THESE
DRAWINGS, OR WHICH PREVENT HIM FROM PERFORMING THE WORK IN ACCORDANCE WITH THE CONTRACT DOCUMENTS.
3. CONTRACTOR IS RESPONSIBLE FOR PROVIDING PROTECTION TO WINDOWS AND FINISHES AND ADJACENT PROPERTIES PRIOR TO START
OF WORK. CONTRACTOR SHALL RE-PLACE ALL WINDOWS AND FINISHES DAMAGED OR STAINED DURING THE WORK.
FOUNDATION NOTES:
1. EXISTING FOUNDATIONS ARE TO BE UTILIZED IN THIS PROJECT. REINFORCING OF EXISTING FOUNDATIONS IS NOT REQUIRED (UNO ON
PLANS).
2. NEW FOUNDATIONS HAVE BEEN DESIGNED TO REST ON INORGANIC, UNDISTURBED SOIL HAVING A PRESUMPTIVE BEARING VALUE OF
2000 PSF. SUCH BEARING STRATA IS ANTICIPATED AT THE BOTTOM OF FOOTING ELEVATIONS NOTED ON THE FOUNDATION PLAN. ALL BEARING STRATA SHALL BE REVIEWED BY THE ENGINEER PRIOR TO POURING CONCRETE IN ORDER TO VERIFY THE PRESUMPTIVE BEARING
VALUE.
3. THE CONTRACTOR SHALL BE RESPONSIBLE FOR LIMITING POURS TO MINIMIZE SHRINKAGE CRACKING. IN GENERAL, WALLS SHALL NOT BE POURED IN CONTINUOUS LENGTHS EXCEEDING 40 FEET. THE LOCATION AND CONFIGURATION OF JOINTS EXPOSED TO VIEW SHALL
BE COORDINATED WITH THE ARCHITECT.
4. STEP FOOTINGS WHERE ELEVATIONS CHANGE AT A MAXIMUM SLOPE OF ONE VERTICAL ON TWO HORIZONTAL AND PLACE LOWER
FOOTING FIRST.
5. ALL SOIL SURROUNDING AND UNDER FOOTINGS SHALL BE PROTECTED FROM FREEZING AND THAWING DURING THE COURSE OF
CONSTRUCTION.
6. THE BOTTOM OF EXTERIOR FOOTINGS NOT ON SOLID ROCK SHALL BE AT LEAST 3'-6" BELOW FINISHED GRADE.
7. IN AREAS REQUIRING FILL, THE FILL MATERIAL SHALL BE A UNIFORMLY GRADED MIXTURE OF SAND AND GRAVEL WEIGHING NO LESS
THAN 120 PCF DRY DENSITY AFTER COMPACTION IN PLACE. THIS MIXTURE SHALL BE UNIFORMLY GRADED HAVING NO STONE GREATER THAN 3 INCHES IN ANY ONE DIMENSION, AND WITH LESS THAN 10%, BY WEIGHT, PASSING A #200 SIEVE. THE FILL SHALL BE PLACED IN MAXIMUM LIFTS OF 8" BEFORE COMPACTION. EACH LIFT SHALL BE COMPACTED WITH APPROPRIATE EQUIPMENT TO A MINIMUM OF 95% OF ITS MAXIMUM DENSITY AT OR NEAR OPTIMUM MOISTURE. A SOILS TESTING LABORATORY, HIRED BY THE OWNER, SHALL TEST THE MATERIAL BEFORE AND AFTER COMPACTION FOR CONFORMANCE WITH THIS SPECIFICATION. NO LIFTS SHALL BE PLACED WHEN WEATHER CONDITIONS ARE SUCH THAT THE MOISTURE CONTENT OF THE FILL CANNOT BE PROPERLY CONTROLLED. IN PLACING AND COMPACTING FILL AND BACKFILL MATERIAL, DO NOT DAMAGE NOR DISPLACE CONCRETE WORK ALREADY IN PLACE BY CONTACT FROM COMPACTION MACHINERY, BY SUBJECTING IT TO OVERTURNING FROM HEAVY COMPACTION LOADING OR ANY OTHER CAUSE. BRING FILL AGAINST SUCH CONCRETE AT THE SAME RATE AS THE REMAINDER OF FILL, COMPACTING UNIFORMLY ON BOTH SIDES USING HAND, OR SAMM MECHANICAL TAMPERS.
8. THE SLAB-ON-GRADE SUB-BASE SHALL BE A CRUSHER RUN STONE FREE FROM SOFT DISINTEGRATED PIECES, MUD, DIRT, OR OTHER INJURIOUS MATERIAL. THE MATERIAL SHALL HAVE NO STONE GREATER THAN 2" IN ANY ONE DIMENSION AND WITH LESS THAN 10%, BY
WEIGHT, PASSING A #100 SIEVE.
STEEL DECK NOTES:
1. STEEL DECK SHALL BE DESIGNED, FABRICATED, AND ERECTED IN ACCORDANCE WITH THE CURRENT SPECIFICATION OF THE STEEL DECK
INSTITUTE.
2. SHOP DRAWINGS SHALL INDICATE THE FINISH, TYPE, GAGE, DIMENSIONS, AND LAYOUT OF ALL DECK AND ACCESSORIES. DRAWINGS
MUST BE SUBMITTED TO THE ENGINEER FOR REVIEW PRIOR TO FABRICATION.
3. FORMED STEEL ROOF DECK TO BE 1-1/2" DEEP, 22 GAGE, GALVANIZED, WIDE RIB, TYPE "B" DECK, AS MANUFACTURED BY UNITED STEEL
DECK, INCORPORATED, OR AN APPROVED EQUAL.
4. THE STEEL DECK SHALL BE SUPPLIED IN MINIMUM LENGTHS AS REQUIRED TO PROVIDE A "3-SPAN" CONDITION. END CLOSURES, ROOF
SUMPS, CLOSURES AT PENETRATIONS, AND ALL OTHER ACCESSORIES NECESSARY FOR A COMPLETE INSTALLATION ARE REQUIRED.
5. FORMED STEEL ROOF DECK SHALL BE WELDED TO SUPPORTING STEEL WITH 5/8" DIAMETER PUDDLE WELDS AT ALL EDGE RIBS PLUS A
SUFFICIENT NUMBER OF INTERIOR RIBS TO LIMIT THE SPACING BETWEEN ADJACENT POINTS OF ATTACHMENT TO 18". INTERMEDIATE SIDE CONNECTIONS SHALL BE MADE WITH #10 SELF-TAPPING SCREWS AT MID-SPAN OR 3'-0" ON CENTER, WHICHEVER IS SMALLER. END
LAPS OF SHEETS SHALL BE A MINIMUM OF 2" AND SHALL OCCUR OVER SUPPORTS.
6. THIS DECK MUST BE PROTECTED BEFORE AND AFTER ERECTION AND ALL DEBRIS CLEANED FROM ITS SURFACE WHERE CONCRETE WILL BE
POURED OR ROOFING IS TO BE PLACED.
ROUGH CARPENTRY:
1. ALL WOOD FRAMING SHALL CONFORM TO THE NATIONAL FOREST PRODUCTS ASSOCIATION "NATIONAL DESIGN STANDARD FOR
WOOD CONSTRUCTION".
2. THE STRUCTURAL WOOD STRESS GRADE STAMPED LUMBER SHALL BE HEM FIR No. 2 OR BETTER, GRADED AS FOLLOWS:
3. JOISTS AND RAFTERS: Fb = 850 PSI, E = 1,300,000 PSI
4. STUDS: Fc = 800 PSI, E = 1,200,000 PSI
5. "I-JOISTS" SHAPED COMPOSITE MEMBERS SHALL BE TJI-JOISTS, AS MANUFACTURED BY THE TRUSS-JOIST CORPORATION, OR AN
APPROVED EQUAL.
6. PARALLAM PSL HEADERS AND BEAMS SHALL BE MANUFACTURED BY TRUS JOIST MACMILLAN (OR AN APPROVED EQUAL) AND SHALL
HAVE A MODULUS OF ELASTICITY OF 2,000,000 PSI, A MINIMUM ALLOWABLE BENDING STRESS OF 3,100 PSI, AN ALLOWABLE COMPRESSION PERPENDICULAR TO GRAIN OF 650 PSI, AND AN ALLOWABLE HORIZONTAL SHEAR OF 290 PSI. 3-1/2" MEMBERS MAY BE TWO PIECES OF 1-3/4" OR A SINGLE 3-1/2" WIDE BEAM. INSTALL IN STRICT ACCORDANCE WITH THE MANUFACTURER'S
RECOMMENDATIONS.
7. THE STRUCTURAL GLU-LAMINATED TIMBER SHOWN ON THESE DRAWINGS SHALL BE DOUGLAS FIR WITH THE FOLLOWING MINIMUM ALLOWABLE UNIT STRESSES: Fb = 2,000 PSI, Fv = 165 PSI, E = 1,800,000.
8. GLU-LAMINATED TIMBER SHALL CONFORM TO THE VOLUNTARY PRODUCT STANDARD, LATEST EDITION, FOR STRUCTURAL
GLU-LAMINATED TIMBER.
9. STRUCTURAL WOOD FRAMING USED IN EXTERIOR APPLICATIONS OR IN CONTACT WITH CONCRETE OR MASONRY SHALL BE SOUTHERN YELLOW PINE, No. 2 OR BETTER, CCA PRESERVATIVE PRESSURE TREATED WOOD.
10. FLUSH-FRAMED CONNECTIONS SHALL BE MADE WITH PREFABRICATED GALVANIZED STEEL HANGERS OF WIDTH AND DEPTH APPROPRIATE FOR THE SUPPORTED MEMBER. INSTALL WITH THE TYPE AND QUANTITY OF FASTENERS RECOMMENDED BY THE
MANUFACTURER.
11. BUILT-UP MEMBERS SHALL HAVE ADJACENT PLIES NAILED TOGETHER WITH TWO ROWS OF NAILS AT 12" O.C. (10d COMMON NAILS FOR 1½" PLIES, 12d COMMON NAILS FOR 1¾" PLIES.
12. UNLESS OTHERWISE NOTED, ALL LUMBER SHALL BE NAILED IN ACCORDANCE WITH THE SPECIFIED NAILING SCHEDULE.
13. ROOF TRUSSES SHALL BE INSTALLED DIRECTLY OVER BEARING STUDS UNLESS OTHERWISE DETAILED.
14. ROOF TRUSSES AND BEAMS SHALL BE SUPPORTED LATERALLY AT EACH SUPPORT BY FULL DEPTH SOLID BLOCKING, EXCEPT WHERE
MEMBERS ARE SUPPORTED BY A FLUSH HEADER OR NAILED TO A RIM BOARD.
15. PROVIDE TWO STUDS AT EACH END OF ALL FLUSH FRAMED HEADERS OR BEAMS, UNLESS MORE ARE INDICATED ON PLAN. PROVIDE
ONE JACK STUD AND ONE FULL STUD AT EACH END OF ALL DROPPED HEADERS OR BEAMS, UNLESS MORE ARE INDICATED ON PLAN.
16. WOOD SILL PLATES SHAOLL BE ATTACHED TO FOUNDATION WALLS WITH ½" DIAMETER BOLTS EMBEDDED AT LEAST 6" INTO CONCRETE
AND SPACED NO MORE THAN 32" ON CENTER. WOOD SILL PLATE SHALL BE PRESSURE-TREATED.
17. PROVIDE HORIZONTAL BLOCKING AT 4'-0" OC VERTICALLY STAGGERED IN ALL BEARING WALLS.
PLYWOOD SHEATHING NOTES:
1. PLYWOOD SHALL CONFORM TO U.S. PRODUCT STANDARD PS-1, AND BEAR THE APA GRADE-TRADEMARK OF THE AMERICAN PLYWOOD
ASSOCIATION.
2. PLYWOOD SHEATHING FOR FLOORS, ROOF, AND WALLS SHALL BE APA GRADED C-D WITH EXTERIOR GLUE. SHEATHING FOR FLOORS
AND WALLS SHALL BE 32/16, EXPOSURE 1. ROOF SHEATHING SHALL BE 5/8" 40/20.
3. PLYWOOD SHEATHING SHALL BE INSTALLED WITH THE LONG DIMENSION OF THE PANEL ACROSS SUPPORTS AND CONTINUOUS OVER
TWO OR MORE SPANS.
4. LAY-UP ROOF PLYWOOD WITH FACE GRAIN PERPENDICULAR TO SUPPORTS. STAGGER JOINTS AND INSTALL BLOCKING AT ALL EDGES.
5. NAIL ROOF PLYWOOD WITH 10d COMMON NAILS AT 6" O.C. AT ALL EDGES AND BOUNDARIES AND AT 12" O.C. AT INTERMEDIATE
SUPPORTS, UNLESS NOTED OTHERWISE.
CONCRETE NOTES:
1. ALL CONCRETE WORK SHALL CONFORM TO ALL THE REQUIREMENTS OF A.C.I. 301 (LATEST EDITION), "SPECIFICATIONS FOR STRUCTURAL
CONCRETE IN BUILDINGS".
2. CONCRETE SHALL BE NORMAL WEIGHT CONCRETE AND SHALL DEVELOP A COMPRESSIVE STRENGTH OF 3000 PSI IN 28 DAYS.
3. ALL DETAILING, FABRICATION AND ERECTION OF REINFORCING BARS, UNLESS OTHERWISE NOTED, MUST FOLLOW THE LATEST ACI CODE
AND THE LATEST ACI "MANUAL OF STANDARD PRACTICE FOR DETAILING REINFORCED CONCRETE STRUCTURES".
4. NO ADMIXTURES ARE PERMITTED WITHOUT THE ENGINEERS WRITTEN PERMISSION OTHER THAN ENTRAINED AIR. CONCRETE EXPOSED
TO THE WEATHER, SUCH AS THAT USED IN FOUNDATION WALLS, SHALL CONTAIN 5% ±1% ENTRAINED AIR.
5. REINFORCING STEEL SHALL CONFORM TO ASTM A 615, GRADE 60.
CONCRETE MASONRY NOTES:
1. ALL CONCRETE MASONRY WORK SHALL CONFORM TO THE REQUIREMENTS OF ACI 530/ASCE 5 (LATEST EDITION),"BUILDING CODE
REQUIREMENTS FOR MASONRY STRUCTURES".
2. CONCRETE BLOCK SHALL BE NORMAL WEIGHT LOAD BEARING MASONRY UNITS CONFORMING TO ASTM C-90, GRADE N-I, WITH A
MINIMUM ULTIMATE COMPRESSIVE STRENGTH OF 1500 PSI ON THE NET AREA OF THE UNITS.
3. MORTAR SHALL BE TYPE M OR S AND CONFORM TO ASTM C-270.
4. CEMENT USED IN THE MORTAR AND GROUT SHALL CONFORM TO ASTM C-150.
5. STEEL REINFORCING BARS SHALL CONFORM TO ASTM A-615, GRADE 60. JOINT (HORIZONTAL) REINFORCEMENT SHALL BE DUR-O-WALL
TRUSS TYPE, OR AN APPROVED EQUAL.
6. MASONRY SHALL NOT BE CONSTRUCTED IN TEMPERATURES BE LOW 40°F. PROVIDE A HEAT SOURCE AND PROTECTION AS REQUIRED
TO MAINTAIN TEMPERATURE ABOVE 40°F.
7. ALL CELLS WITH REINFORCING BARS OR BOLTS SHALL BE GROUTED SOLID.
8. ALL CELLS BELOW FINISH GRADE SHALL BE GROUTED SOLID.
9. VERTICAL CELLS TO BE GROUTED SOLID SHALL HAVE A MINIMUM CLEAR OPENING OF 3" x 2-1/2".
10. CONSOLIDATE GROUT POURS EXCEEDING 12 INCHES IN HEIGHT BY MECHANICAL VIBRATION AND RECONSOLIDATE BY MECHANICAL
VIBRATION AFTER INITIAL WATER LOSS AND SETTLEMENT HAS OCCURRED.
11. CERTIFICATES OF COMPLIANCE ARE REQUIRED TO BE SUBMITTED TO THE ARCHITECT AND ENGINEER FOR BLOCK GRADE AND STRENGTH, GROUT, MORTAR, AND REINFORCING BARS PRIOR TO DELIVERY OF THE BLOCK.
12. THE CONCRETE MASONRY ON THIS PROJECT HAS BEEN DESIGNED USING REDUCED ALLOWABLE STRESSES, AND THEREFORE DOES NOT
REQUIRE SPECIAL INSPECTIONS.
STRUCTURAL STEEL NOTES:
1. DESIGN, FABRICATION AND ERECTION OF STRUCTURAL STEEL SHALL CONFORM TO THE "SPECIFICATION FOR THE DESIGN, FABRICATION, AND ERECTION OF STRUCTURAL STEEL FOR BUILDINGS", LATEST EDITION, AS ADOPTED BY THE AMERICAN INSTITUTE OF STEEL
CONSTRUCTION.
2. MATERIALS
3. STRUCTURAL STEEL, W-SHAPES ASTM A 992, FY = 50,000 PSI
4. CHANNELS, ANGLES ASTM A 36, FY = 36,000 PSI
5. STRUCTURAL STEEL TUBING, SQUARE ASTM A 500 GRADE B
6. STRUCTURAL STEEL TUBING, ROUND ASTM A 53 TYPE S
7. BOLTS ASTM A 325
8. ANCHOR BOLTS ASTM A307
9. WELDING ELECTRODE ASTM E 70XX LOW HYDROGEN
10. ALL WELDING SHALL CONFORM TO THE CODE FOR ARC AND GAS WELDING IN BUILDING CONSTRUCTION OF THE AMERICAN WELDING
SOCIETY, AND BE PERFORMED BY A CERTIFIED WELDER IN ACCORDANCE WITH A.W.S. STANDARDS.
11. ALL STRUCTURAL STEEL BEAMS AND COLUMNS ADJACENT TO MASONRY TO HAVE 1-1/2" x 1/8" STRAP ANCHORS AT 2'-8" ON CENTER, UNLESS OTHERWISE NOTED.
12. PROVIDE 9/16" HOLES FOR WOOD NAILERS AS REQUIRED BY ARCHITECTURAL DRAWINGS.
13. STRUCTURAL STEEL SHALL BE CLEANED IN ACCORDANCE WITH THE STEEL STRUCTURES PAINTING COUNCIL SPECIFICATION SP-3-82 FOR
POWER TOOL CLEANING AND PAINTED TO A MINIMUM DRY FILM THICKNESS OF 2 MILS WITH A SHOP COAT OF TNEMEC #10-99 ALKYD RUST INHIBITIVE PRIMER AS MANUFACTURED BY TNEMEC COMPANY, INC., OF KANSAS CITY, MO, OR AN APPROVED EQUAL.
AutoCAD SHX Text
REINFORCEMENT, WWF 6X6, WI.4X WI.4 PROVIDE CHAIRS TO MAINTAIN ELEVATION AS SHOWN
AutoCAD SHX Text
6 MIL POLYETHYLENE VAPOR BARRIER LAP
AutoCAD SHX Text
GRANULAR SUB-BASE
AutoCAD SHX Text
NATURAL CUT GRADE OR COMPACTED SUB-GRADE
AutoCAD SHX Text 3 7/16"
AutoCAD SHX Text 4"
AutoCAD SHX Text 4"
AutoCAD SHX Text
1 - TYPICAL SLAB-ON- GRADE DETAIL
AutoCAD SHX Text
SCALE: " = 1'-0"34" = 1'-0"
AutoCAD SHX Text
FND-71
AutoCAD SHX Text
FND-72
AutoCAD SHX Text
STOP REINF. 6" SHORT OF JOINT AT EACH SIDE
AutoCAD SHX Text
6 MIL POLYETHYLENE VAPOR BARRIER LAP
AutoCAD SHX Text
GRANULAR SUB-BASE
AutoCAD SHX Text
NATURAL CUT GRADE OR COMPACTED SUB-GRADE
AutoCAD SHX Text
2 - TYPICAL CONTROL JOINT DETAIL
AutoCAD SHX Text
SCALE: " = 1'-0"34" = 1'-0"
AutoCAD SHX Text
DIAMOND SAW CUT JOIN AND FILL W/SPECIFIED JOINT FILLER
AutoCAD SHX Text 1 1/2"
AutoCAD SHX Text NOTE: A. SAW-CUT IS TO BE PERFORMED WITHIN 24 HRS OF THE CONCRETE PLACEMENT. REFFER TO ACI 301-84 AND 302. B. SEE SLAB PLAN FOR CONTROL JOINT LOCATIONS. NOTED'CJ' C. SEE TYP SLAB-ON-GRADE DETAIL FOR INFORMATION NOT SHOWN HERE
AutoCAD SHX Text 8"
AutoCAD SHX Text
SEE PLAN FOR LIMITS OF CONC. PAD
AutoCAD SHX Text
4 - TYPICAL EXTERIOR WALL AT DOOR
AutoCAD SHX Text
3'-0" (MIN.)
AutoCAD SHX Text #4 BENT BARS @ 16" o.c. BEND AROUND #4 NOSING BAR
AutoCAD SHX Text SCALE: ~w"=1'-0"
AutoCAD SHX Text
SEE FDN PLAN FOR DIMENSIONS AND BAR SIZES
AutoCAD SHX Text
(2) #5
AutoCAD SHX Text 8"
AutoCAD SHX Text 5"
AutoCAD SHX Text
GROUT ALL CELLS SOLID
AutoCAD SHX Text BOND BEAM w/ (2) #5 BARS
AutoCAD SHX Text
EXTERIOR GRADE VARIES SEE SITE PLAN
AutoCAD SHX Text
WRAP MESH AROUND #4 NOSING BAR
AutoCAD SHX Text #3 @ 12" o.c. E.W.
AutoCAD SHX Text
STEEL ~< WITH WELDED ANCHOR
AutoCAD SHX Text T
AutoCAD SHX Text
WATERSTOP
AutoCAD SHX Text 8"
AutoCAD SHX Text 1'-0"
AutoCAD SHX Text SCALE: ~w"=1'-0"
AutoCAD SHX Text
3 - FOUNDATION DRAIN DETAIL
AutoCAD SHX Text 2'-0"
AutoCAD SHX Text 6"
AutoCAD SHX Text 6"
AutoCAD SHX Text 1'-0"
AutoCAD SHX Text
METAL GRATE
AutoCAD SHX Text
INTERIOR
AutoCAD SHX Text
EXTERIOR
'-9
/8
31'-4 1/2"
31'-3 7/8"
PHASE TWO
-7
/8 " D
EE
P
TJ
I
" O .C
SE
E N
O
TE
'A
') RTU WT =
3500 LBS
2X6 STUD BEARING WALL
(3 ) 1
3 4 x
-7 /8
"L
VL
2x4 @ 16" O.C
BEARING WALL
9'-0" 5'-6"7'-10" 7'-10"
NOTE 'A'
BEFORE LIVE LOAD = 30 PSI
DENOTES 2X4 WELL
PROVIDE SIMPSON -TIE ___ ANCHOR @ EACH END
*COORDINATE RTU LOCATION W/ MECHANICAL
EXISTING LINTEL
(3) - 2X10
EXISTING LINTEL
(3) - 2X10
W8X10 CMU HEADER
(8" MIN , EACH END)
(2) - 2X10 @ NEW
STUD WALL
(3) - 2X10
RTU WT =
1135 LBS
RTU WT =
975 LBS
(3) 2X8
@NEW STUD WALL EXIST.
LINTEL TO REMAIN IN
EXISTING WALL
@NEW STUD WALL EXIST.
LINTEL TO REMAIN IN
EXISTING WALL
PHASE TWO PHASE ONE
9'-5 1/2"
(3 ) 1
3 4 x
-7 /8
"L
VL
(3 ) 1
3 4 x
-7 /8
"L
VL
(3 ) 1
3 4 x
-7 /8
"L
VL
(3 ) 1
3 4 x
-7 /8
"L
VL
-7
/8 " D
EE
P
TJ
I
" O .C
SE
E N
O
TE
'A
2'-9 3/4"
18'-0"
(3) 2X8 (3) 2X8(3) 2X8
4"-THICK, SLAB ON GRADE W/
10 MIL POLY. VAPOR & GRAVEL BASE
(W/ COMPACTED SUB-BASE)
2'-0"
99'-10"
2'-0"
2' -0
CONTINUOUS CONCRETE
FOUNDATION WALL & FOOTING
2'-0"
101'-0 3/8"
5' -9
1/ 4"
'-4
/4
POLES
'-9
/8
31'-4 1/2"
5' -2
1/ 8"9 5/8"
5/
8"
9 5/8"
'-1
1 7 /8
31'-3 7/8"
PHASE TWO
PHASE TWO PHASE ONE
PHASE 1 FOUNDATION
S2.1
S1.1
S1.1
S1.1
S1.1
S1.1
S1.1
S2.1
C.J.
C.J.
C.J.
C.J. C.J. C.J. C.J. C.J. C.J. C.J. C.J. C.J. C.J. C.J.
C.J.
C.J.
4"-THICK, SLAB ON GRADE W/
10 MIL POLY. VAPOR & GRAVEL BASE
(W/ COMPACTED SUB-BASE)
NOTE: SPACE CONTROL JOINTS IN
SLAB NO MORE THAN 8'-0" IN
BOTH DIRECTIONS CONC. PAD WITH TURNED
DOWN FROST WALL @
PERIMETER
S2.1
S1.1
TYP.
S1 .12
TY
P.
OR S2.1
S2.1
2'-9 3/4"
TYP.
2'-0"
1'- 0"
3"
(3) #4's CONTINUOUS
3' -0
" M
IN
FR
O
ST
P
RO
TE
CT
IO
N GROUT ALL
CELLS SOLID
#4 NOSING BAR
(2) #4's IN
CONTINUOUS
BOND BEAM
HDG ANCHOR BOLT
6" CMU
1" THERMAL BREAK
2" RIGID
PERIMETER
INSULATION
(TYP)
BO
TT
O M
O F
FO
O
TI
N
G 3'
-0 " M
IN
. B
EL
O
W G
RA
DE
EXISTING
BUILDING
EX
3' -0
BE
LO
W
G
RA
DE
#4 NOSING BAR
NEW
ADDITION
NEW BEARING WALL
FOOTING TO BEAR ON
EXISTING FOOTING
2'-0"
1'- 0"
3' -0
" M
IN
FR
O
ST
P
RO
TE
CT
IO
N
(2) #4's CONTINUOUS
TOP & BOTTOM
1'-0"
6"
MIN.
SLAB
BRG.
EX
TE
N D
CO
N
CR
ET
E 8"
A
BO
VE
S
LA
B
WRAP MESH AROUND
#4 NOSING BAR
(3) #4's CONTINUOUS
4" CONC. SLAB
W/
5 1/2"
CONC.
STUB
WALL
P.T. 2X6 BASE PLATE
P.T. PLATE W/
SILL SEAL
STRUCTURAL
PLANS
S2.1
3515 Sunnyside Road Center Valley, PA 18034
T: 610-297-0140 E: sam@scf-arch.com These documents are instruments of the Architect's service for use solely with respect to this project.
The Architect shall retain all common law, statutory and other reserved rights, including the copyright.
They are not to be used for any purpose by any other party outside of the scope of this work without the specific written consent of the Architect.
L LC
STRUCTURAL ENGINEER OF RECORD:
101 NORTH QUEBEC STREET
ALLENTOWN, PA, 18109)
610-437-0978 bcohen@baseeng.com
M O
U N
T
BE
TH
EL
F
IR
E
CO
AD
DI
TI
O N
T O
E
XI
ST
IN
G
FI
RE
C
O M
PA
N
Y
N or th
D el aw ar e Dr iv e, M t.
Be th el , P
A
U pp er M ou nt
B et he l, N or th am pt on
C ou nt y
ARCHITECT OF RECORD:
Samantha Ciotti Falcone
AIA, LEED AP
DRAWN BY:
BID DOCUMENTS
6/23/2026
REV1
REV2
OWNER:
Mt. Bethel Fire Co.
ML, SCF
BARRY ISETT & ASSOCIATES
570-688-8268 dalehandelong@hotmail.com
MEP ENGINEER OF RECORD:
5420 Crackersport Rd Allentown, PA 18104
610-437-0978 EMAIL: dhorsfield@barryisett.com
BASE ENGINEERING
SCALE:2 STRUCTURAL - FOUNDATION PLAN
1/4"=1'-0"
SCALE:1 STRUCTURAL - ROOF FRAMING PLAN
1/4"=1'-0"
NOTE 'A'
RAFTER LIVE LOAD = 30 psf
COORDINATE RTU LOCATION W/
MECHANICAL DRAWING.
NEW 2X4 SHEAR WALL -
PROVIDE SIMPSON
STRONG-TIE LATERAL
ANCHOR @ EACH END
LEGEND
SCALE:4 SECTION DETAIL
1"=1'-0"SCALE:3 SECTION DETAIL
1"=1'-0" SCALE:5 SECTION DETAIL
1"=1'-0"
AutoCAD SHX Text P6
AutoCAD SHX Text
EW1
AutoCAD SHX Text
EW1
AutoCAD SHX Text P9
AutoCAD SHX Text P6
AutoCAD SHX Text
EW1
AutoCAD SHX Text
EW1
AutoCAD SHX Text P9
| Sheets and Views |
| Unsaved Drawing4-S1.1 struct |
| Unsaved Drawing4-S2.2 struct |
File details come from the government source that posted it. Updated .