1-Ceramics Kiln Specifications.doc
DOC document 33 KB Posted
- Attached to
- IFB - HHS Replacement Kiln
- Solicitation number
- WCSD-MH-003
- Issued by
- Weber County, Utah
About this file
This is a Ceramics Kiln Specifications document prepared by the Washington County School District Purchasing Department in Utah for the replacement of a kiln at Hurricane High School. The specifications detail the technical requirements and performance standards for a new ceramics kiln, establishing the baseline expectations for vendors submitting bids in response to the related Invitation for Bid (IFB). The document outlines the functional capabilities, safety features, and operational parameters that the replacement kiln must meet to serve the school district's ceramics program.
The specifications establish detailed technical requirements including kiln type, temperature capabilities, chamber dimensions, control systems, safety features, and installation requirements necessary for the equipment to function effectively in an educational environment. Vendors responding to this IFB must guarantee their pricing for 30 days and provide equipment that meets or exceeds all specified standards. The contract award will be made to the lowest cost responsive and responsible vendor, and the procurement process is governed by the State of Utah Procurement Code (UCA Chapter 63G-6a) and applicable Utah Administrative Rules.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| 2-Attachment Cost Submittal Sheet.xlsx | XLSX spreadsheet |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
SPECIFICATIONS FOR BID
1. General Specifications
· Firing Volume: Minimum 18 cu. ft. actual stacking space.
· Kiln Type: Front-loading, downdraft design.
· Temperature Rating: Minimum Cone 12 capability.
· Fuel Source: Natural Gas.
· Certification: Must be ETL or UL listed to meet school district fire safety codes.
2. Construction & Insulation
· Interior Lining: High-temperature insulating firebrick (IFB) with a minimum 2300°F or 2600°F rating depending on zone.
· Structural Frame: Heavy-duty structural steel (angle iron and tube steel) with a heat-resistant coating.
· Exterior Skin: Minimum 16-gauge steel or stainless steel.
· Preference: Ventilated double-skin construction to maintain low exterior surface temperatures.
· Door: Heavy-duty hinged door with multi-point adjustable latching system and integrated viewport (spyhole) with plugs.
3. Burner & Safety Systems
· Burner Type: High-efficiency natural draft venturi burners or forced-air system (minimum 4–6 burners).
· Safety Shut-off: 100% electronic flame safety system with automatic gas shut-off in the event of flame failure or power loss.
· Ignition: Push-button electronic spark ignition.
· Pressure Gauge: Integrated gas pressure gauge (0–15" W.C).
4. Controls & Instrumentation
· Controller: Digital programmable high-limit/soak controller for precise temperature monitoring.
· Thermocouple: Type K or Type S heavy-duty thermocouple with ceramic protection tube.
· Damper: Adjustable manual sliding damper for atmosphere control (reduction/oxidation).