1-Attachment B - Technical Specs.pdf

PDF 145 KB Posted

Attached to
Soils, Top Dressing, and Top Soil
Solicitation number
IFB 2000004201
Issued by
Fairfax County, Virginia

About this file

This document is a Technical Specification Sheet (Attachment B) for Invitation for Bid (IFB) 2000004201, detailing precise specifications for various soil and sand materials. The document covers five distinct product categories: sterilized straight sand (Item 1), non-sterilized straight sand for fairways and athletic fields (Item 2), premium topsoil (Item 3), general topsoil (Item 4), and bunker sand (Item 5). Each item has extensive technical requirements, including detailed specifications for particle size, chemical composition, organic matter content, infiltration rates, and purity standards.

The specification sheet provides rigorous technical parameters for each material type, requiring specific testing methodologies such as ASTM standards and Ammonium Acetate test methods. For example, the bunker sand must be tested by an A2LA-accredited laboratory and meet precise criteria for particle size, color, infiltration rate, and penetrometer value. Contractors are instructed to unload all materials in a designated FCPA delivery area, and several materials have brand-specific references like Luck Stone "Premium Top Soil" and U.S. Silica "CEC Sand" with allowances for equivalent products. The document serves as a comprehensive technical guide for precise material procurement with exacting quality control standards.

View the file

Other files

File Type Posted
6-Addendum 1.pdf PDF
2-DPMM Cover Sheet.pdf PDF
3-Appendix A.pdf PDF
4-Attachment A.pdf PDF
5-2000004201.pdf PDF

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

IFB 2000004201

ATTACHMENT B

TECHNICAL SPECIFICATION SHEET

Contractor personnel will unload all materials and place them in the FCPA designated delivery area.

PART 1:

TOP DRESSING, STERILIZED STRAIGHT SAND (Item 1)

Must meet USGA standards.

Infiltration rate: 25” (min) - 40” per hr.

97% (min.) natural, sub-angular sand, 95% pure silica

Silt and clay: ≤ 3%

Sand Practices Size: 0% retained

1.0 mm: ≤ 5%

0.25 mm - .5mm: ≥ 60%

0.15 mm: ≤ 20%

0.05 mm – 0.10mm: ≤ 5%

PART 2:

TOP DRESSING, STRAIGHT SAND, NOT STERILIZED (Item 2)

Fairway and athletic field type

U.S. Silica “CEC Sand” or (equal)

Sand: 97% (95% min.) natural type

Silt and clay: ≤ 3% combined (5% max)

Organic Matter: <1%

Ksat Infiltration Rate: 12 inches per hour (10” min)

C.E.C: 5.0 meq/100g(4.0 min)

Sand Practices Size: 0% retained

2mm (gravel): ≤ 2%

1.0 mm: ≤ 5%

0.25 mm - .5mm: ≥ 60%

0.15 mm: ≤ 22%

0.05 mm – 0.10mm: ≤ 8%

Soluble Chemical Analysis: (Ammonium Acetate test method)

Calcium (Ca): 500 ppm (400 min)

Magnesium (Mg): 125 ppm (100 min)

Sodium (Na): 10 ppm (25 max)

Manganese (Mn): 15 ppm (10 min)

Iron (Fe) 100 ppm (75 min)

PART 3:

TOP SOIL – PREMIUM (Item 3)

Luck Stone “Premium Top Soil” or equal. Raw soil shall be naturally occurring, mined type and screened to 6mm (min). Must be free of glass, sticks and other undesirable contaminants. Finished topsoil shall be blended in a pug mill (or equal) with organic compost to create a homogeneous mix.

Textural Class: Sandy Loam pH – approximately 6.5 (6.3 min – 7.2% max)

Organic Matter content: approx. 4.0% (3.5% min)

CEC – approx. 10.0 (7.0 min – 13.0 max)

Sand – 70% (62% min – 78% max)

Silt – 20% (25% max)

Clay – 10% (15% max)

Calcium (Ca): 1200 ppm (1000 min – 1600 max)

Magnesium (Mg): 120 ppm (100 min – 175 max)

Potassium (K): 150 ppm (125 min – 300 max)

Phosphorous (P): 60 ppm (40 min – 125 max)

Soluble Salts: <1.00 ms/cm

PART 4:

TOP SOIL – GENERAL (Item 4)

Shredded and screened to 1” (min). Natural, original surface soil. Reasonably free of sticks and stones and natural debris. Must be free of glass, sticks and other undesirable contaminants.

PH – approximately 6.3 (6.0 min)

Organic Matter content: approx. 2.5% (2.0% min)

PART 5:

BUNKER SAND (Item 5)

Bunker Sand must meet or exceed the bunker sand requirements specified below.

All Bunker Sand test report shall be prepared by a laboratory accredited by the American Association for Laboratory Accreditation (A2LA), and shall include the bunker analysis and the particle size analysis.

Particle Size Analysis (ASTM F1632)

(Required Values)

Soil Separate %

Silt ≤ 1%

Clay ≤ 1%

Sive Size/Sand Fraction

Sand Particle Diameter % Retained

No. 10 Gravel 2 mm ≤ 2%

No. 18 V. Coarse 1 mm ≤ 15%

No. 35 Coarse 0.5 mm 82 – 100%

No. 60 Medium 0.25 mm 82 – 100%

No. 140 Fine 0.10 mm 82 – 100%

No. 270 V. Fine 0.05 mm ≤ 4%

Bunker Sand Analysis

(Required Values)

Crusting (Ref 1) None

Color Munsell Charts White

Infiltration Rate (m/hr)

ASTM F1815-06 ≥ 30

Penetrometer Value (kg/cm2) (Ref 1) ≥ 2.2

File details come from the government source that posted it. Updated .