1_-_Airport_Reservoir_-_Final_Plans.pdf
PDF 2 MB Posted
- Attached to
- Airport Reservoir Rehabilitation Project
- Solicitation number
- WA-26-14826
- Issued by
- Santa Cruz County, California
About this file
These are construction plans for the Airport Reservoir Rehabilitation Project prepared by the City of Watsonville, California Department of Public Works & Utilities in Santa Cruz County. The project rehabilitates an existing welded steel potable water reservoir (Reservoir 'A') located at Watsonville Municipal Airport. The primary scope of work includes blasting, repairing, and recoating the tank interior and exterior surfaces in accordance with specifications; installing fall protection tie-off anchors; mitigating and repairing structural degradation identified during coating removal; and rehabilitating the existing tank vent. Tank exterior recoating is designated as an add/alternate item to be exercised at bid award. The tank has a 150-foot diameter, and the project involves comprehensive structural repairs to the tank shell, bottom, roof plate, and rafters as needed following coating removal and ultrasonic testing to assess material thickness and section loss. The City will fully drain the tank prior to construction, and the cost of one fill will be covered by the City, with any subsequent fills charged to the contractor. Construction hours are restricted to 8:00 AM to 4:00 PM, with operations outside these hours or on city holidays requiring prior approval. The contractor must provide a record set of as-built drawings upon completion and maintain the work area in a neat, safe, and sanitary condition while protecting all existing utilities and structures.
The plans specify that all structural steel construction shall conform to AISC 360-16 and AISC 341-16 standards, with all welding performed by AWS-certified welders using E-70XX electrodes and conforming to AWS D1.1 and D1.8 specifications. Special inspection is required for all structural steel and welding operations, with inspection and testing provided by an approved agency per California Building Code Section 1704. The existing tank coating has tested positive for lead, requiring lead-based coating removal in accordance with specification 099198. Existing tank facilities will be temporarily removed from service during construction, with the contractor responsible for coordinating with the City to minimize impacts. The contractor is responsible for verifying all existing conditions, dimensions, and elevations, and must notify the City immediately of any discrepancies between plans and actual site conditions. Tank repairs shall follow API 653 standards, particularly for bottom plate repairs. The project requires contractor compliance with California Occupational Safety and Health Act provisions and Santa Cruz County Noise Ordinance requirements, which prohibit noise exceeding 75 decibels at the property line during specified hours.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
PROJECT AREA
AI
RP
ORT
B
LV
D
BU
RC
HE
LL
A
VE
WATSONVILLE
MUNICIPAL
AIRPORT
AVIATION WAY
BUENA VISTA DR
FREEDOM BLVD
CONSTRUCTION PLANS
DEPARTMENT OF PUBLIC WORKS & UTILITIES
SANTA CRUZ COUNTY, CALIFORNIA
CITY OF WATSONVILLE
SHEET INDEX
SHEET: DRAWING: TITLE:
1 G-1 TITLE SHEET, SHEET INDEX, VICINITY MAP, AND LOCATION MAP
2 G-2 NOTES, SYMBOLS, ABBREVIATIONS, LEGEND, AND PROJECT SUMMARY
3 C-1 AIRPORT TANK SITE PLAN AND DETAILS
4 S-1 STRUCTURAL NOTES
5 S-2 TANK FOUNDATION AND ROOF FRAMING PLAN
6 S-3 TYPICAL REPAIR DETAILS
SCALE 1" = 1 MILES
VICINITY MAP
CORRALITOS
DAY VALLEY
APTOS
CAPITOLA
WATSONVILLE
INTERLAKEN
FREEDOM
AMESTIAPTOS HILLS -
LARKIN VALLEY
RIO DEL
MAR
PACIFIC
OCEAN
PROJECT
LOCATION
AIRPORT TANK REHABILITATION PROJECT
LOCATION MAP
SCALE 1" = 500 FEET
TITLE SHEET, SHEET INDEX, VICINITY MAP, AND LOCATION MAP
G-1 1 6
CITY OF WATSONVILLE, CALIFORNIA
PUBLIC WORKS, ENGINEERING DEPARTMENT
APPROVED: DATE
MARIA ESTHER CARRANZA RODRIGUEZ, CITY ENGINEER
DESIGN: JAA
CHECKED: TNH
SCALE: AS SHOWN
JOB No. CIWAT.230372.03
REV. No. DATE REVISION DESCRIPTION BY
SCALE IS IN INCHES
FOR REDUCED PLANS ORIGINAL 43210
XX-XX-XXXX
C:
\B ox \P ro je ct s\
CI
W
AT
W at so nv ille
\C
IW
AT
.2
2.
A irp or t R es R eh ab
\5 E ng
CA
D\
Sh ee ts
\T itle
S he et
Ai rp or t R es er vo ir.
dw g
W ed
7.
M ay
.2
0:
:0
AM b y:
Jo na th an M aa s
OF
800/811-642-2444
TOLL FREEUSACALL
TWO DAYS BEFORE YOU DIG
AIRPORT TANK REHABILITATION PROJECT
2025 Gateway Place, Suite 328 San Jose, CA 95110
805-692-6921 | www.mnsengineers.com
CITY OF WATSONVILLE, CALIFORNIA
PUBLIC WORKS, ENGINEERING DEPARTMENT
APPROVED: DATE
MARIA ESTHER CARRANZA RODRIGUEZ, CITY ENGINEER
DESIGN: JAA
CHECKED: TNH
SCALE: AS SHOWN
JOB No. CIWAT.230372.03
REV. No. DATE REVISION DESCRIPTION BY
SCALE IS IN INCHES
FOR REDUCED PLANS ORIGINAL 43210
XX-XX-XXXX
C:
\B ox \P ro je ct s\
CI
W
AT
W at so nv ille
\C
IW
AT
.2
2.
A irp or t R es R eh ab
\5 E ng
CA
D\
Sh ee ts
\T itle
S he et
Ai rp or t R es er vo ir.
dw g
W ed
7.
M ay
.2
0:
:0
AM b y:
Jo na th an M aa s
OF
800/811-642-2444
TOLL FREEUSACALL
TWO DAYS BEFORE YOU DIG
AIRPORT TANK REHABILITATION PROJECT
2025 Gateway Place, Suite 328 San Jose, CA 95110
805-692-6921 | www.mnsengineers.com
Ø DIAMETER
AB AGGREGATE BASE
AC ASPHALT CONCRETE
AVE AVENUE
BC BEGIN CURVE
B.F. BUTTERFLY VALVE
C CHEMICAL
CCR CALIFORNIA CODE OF REGULATIONS
C.I. CAST IRON
CL CENTERLINE
CMLC CEMENT MORTAR LINED AND COATED STEEL
PIPE
CMP CORRUGATED METAL PIPE
CP CONTROL POINT
DEMO DEMOLITON
DIP/D.I. DUCTILE IRON PIPE
E EAST(ING, ERN)
(E) EXISTING
EB EASTBOUND
EC END CURVE
ELEV ELEVATION
FLG FLANGE
FPC FLEXIBLE PIPE COUPLING
FT. FOOT (FEET)
GAL GALLONS
GPM GALLONS PER MINUTE
INV INVERT
LF LINEAR FEET
MH MANHOLE
N NORTH(ING, ERN)
(N) NEW
NAD83 NORTH AMERICAN DATUM OF 1983
NAVD83 NORTH AMERICAN VERTICAL DATUM OF 1983
NPT NATIONAL PIPE THREAD
N.T.S. NOT TO SCALE
PE PLAIN END
PROP PROPOSED
PVC POLYVINYL CHLORIDE
RCP REINFORCED CONCRETE PIPE
RD ROAD
R.O.W. RIGHT OF WAY
S SOUTH(ERN), SLOPE
SD STORM DRAIN
SDMH STORM DRAIN MANHOLE
SDR STANDARD DIMENSION RATIO
SF SQUARE FEET
SPEC SPECIFICATIONS
SPPWC STANDARD PLANS FOR PUBLIC WORKS
CONSTRUCTION
SSPWC STANDARD SPECFICIATIONS FOR PUBLIC
WORKS CONSTRUCTION
SS SANITARY SEWER
SSMH SANITARY SEWER MANHOLE
ST STREET
STA STATION
STD STANDARD DRAWING
TD TANK DRAIN
TYP TYPICAL
VCP VITRIFIED CLAY PIPE
W WEST(ERN)
WB WESTBOUND
WMC WATSONVILLE MUNICIPAL CODE
ABBREVIATIONS
LEGEND
EXISTING STORM WATER PIPE
EXISTING WATER MAIN
EXISTING IRRIGATION
DESIGN PIPE/FITTING/STRUCTURE
EXISTING COMMUNICATIONS CONDUIT
1. THE CITY OF WATSONVILLE (CITY) WILL MANAGE THE PROJECT DURING CONSTRUCTION. THE CITY SHALL BE NOTIFIED AT LEAST 2 WORKING DAYS PRIOR TO BEGINNING CONSTRUCTION AND ANY REQUIRED
INSPECTION.
2. CONTRACTOR SHALL MAINTAIN THE WORK AREA IN A NEAT, SAFE, CLEAN AND SANITARY CONDITION AT ALL TIMES. STREETS SHALL BE KEPT CLEAN OF DEBRIS, WITH DUST AND NUISANCE BEING CONTROLLED
AT ALL TIMES.
3. CONTRACTOR SHALL PROVIDE ALL FALL PROTECTION OR OTHER DEVICES NECESSARY TO PROVIDE FOR SAFETY IN ACCORDANCE WITH CALOSHA.
4. CONTRACTOR SHALL PROTECT ALL EXISTING SURFACES, PIPES, VALVES, EQUIPMENT, ELECTRONIC DEVICES, WIRING, HARDWARE, AND OTHER ITEMS IN THE VICINITY OF WORK AREAS.
5. ALL SURPLUS MATERIALS REMOVED, WHICH ARE NOT SUITABLE FOR USE IN THIS PROJECT, SHALL BECOME THE PROPERTY OF THE CONTRACTOR AND SHALL BE DISPOSED OF AWAY FROM THE JOB SITE IN A
MANNER AND AT A LOCATION ACCEPTABLE TO ALL RESPONSIBLE AGENCIES.
6. LOCATIONS AND DIMENSIONS OF EXISTING STRUCTURES, PIPING, VALVES, AND APPURTENANCES ARE BASED ON RECORD DRAWINGS. CONTRACTOR IS RESPONSIBLE FOR VERIFYING LOCATION, DIMENSIONS, AND ELEVATIONS OF EXISTING VAULTS, SUPPORTS, PIPING, EQUIPMENT, CONCRETE, AND APPURTENANCES. IF ANY DISCREPANCIES EXIST BETWEEN PLANS AND EXISTING FACILITIES ARE IDENTIFIED THAT MAY
AFFECT PROPOSED IMPROVEMENTS, CONTRACTOR SHALL NOTIFY THE CITY IMMEDIATELY.
7. THE EXISTING FACILITIES WILL TEMPORARILY BE REMOVED FROM SERVICE DURING CONSTRUCTION. THE CONTRACTOR SHALL COORDINATE WITH THE CITY TO AVOID IMPACTS TO THE FACILITIES. SEE
SPECIFICATIONS FOR ADDITIONAL REQUIREMENTS TO PROTECTING EXISTING FACILITIES.
8. THE CONTRACTOR SHALL BE RESPONSIBLE FOR DAMAGE TO ALL EXISTING UTILITIES, PAVEMENT, CURB, TRAFFIC STRIPING AND MARKINGS, STRUCTURES, TREES, LANDSCAPING, AND IRRIGATION SYSTEMS AS A RESULT OF HIS OR HER OPERATIONS, AND WILL BE REQUIRED TO REPAIR OR REPLACE SAME TO THE SATISFACTION OF, AND AS DIRECTED BY, THE CITY'S REPRESENTATIVE OR IMPACTED FACILITY OWNER.
9. THE CONTRACTOR SHALL MAINTAIN AND PROVIDE THE CITY WITH A "RECORD" SET OF AS-BUILT DRAWINGS AT THE COMPLETION OF ALL WORK PER THE PLANS AND SPECIFICATIONS.
10. CONTRACTOR SHALL CONTACT THE CITY 3 DAYS PRIOR TO ANY CONSTRUCTION.
11. CONSTRUCTION SITE SHALL BE MAINTAINED IN SUCH A CONDITION THAT AN UNANTICIPATED STORM DOES NOT CARRY WASTES OR POLLUTANTS OFF THE SITE. SUCH "DISCHARGES" OF MATERIAL OTHER THAN STORMWATER ARE ALLOWED ONLY WHEN NECESSARY FOR PERFORMANCE AND COMPLETION OF CONSTRUCTION PRACTICES AND WHERE THEY DO NOT: CAUSE OR CONTRIBUTE TO A VIOLATION OF ANY WATER QUALITY STANDARD; CAUSE OR THREATEN TO CAUSE POLLUTION, CONTAMINATION, OR NUISANCE; OR CONTAIN A HAZARDOUS SUBSTANCE IN A QUANTITY REPORTABLE UNDER FEDERAL REGULATIONS 40 CFR PARTS 117 AND 302. MATERIALS WHICH MAY HAVE EFFECTS OF POLLUTION INCLUDE BUT ARE NOT LIMITED TO: SUSPENDED SOLIDS; ERODED SOILS; SOLID OR LIQUID CHEMICAL SPILLS; WASTES FROM
PAINTS, STAINS, SEALANTS, GLUES, AND SOLVENTS.
12. HOURS OF CONSTRUCTION WILL BE FROM 8:00 AM TO 4:00 PM. CONTRACTOR OPERATIONS OUTSIDE OF THESE HOURS OR ON CITY HOLIDAYS WILL REQUIRE CITY APPROVAL.
13. ALL STAGING AND STORING OF CONSTRUCTION MATERIAL IS TO BE DONE OFFSITE OR WITHIN DESIGNATED AREAS, AS APPROVED BY THE CITY.
14. EXISTING TANK COATING HAS BEEN TESTED FOR LEAD AND LEAD WAS FOUND TO BE PRESENT. REFER TO SPECIFICATION 099198 FOR DETAILS ON REMOVAL OF LEAD-BASED COATINGS.
GENERAL NOTES
ABANDON
DEMOLISH
FENCE
CONCRETE
AC PAVEMENT
AGGREGATE BASE
PROJECT SUMMARY
REHABILITATE THE EXISTING AIRPORT WELDED STEEL POTABLE WATER RESERVOIR 'A', INCLUDING THE FOLLOWING
WORK ELEMENTS:
1. BLAST, REPAIR, AND RECOAT TANK INTERIOR AND EXTERIOR IN ACCORDANCE WITH THE SPECIFICATIONS.
2. INSTALL FALL PROTECTION TIE-OFFS.
3. MITIGATE AND REPAIR STRUCTURAL DEGRADATION.
4. REHABILITATE EXISTING TANK VENT.
SITE ACCESS AND OPERATIONAL COORDINATION NOTES
SOIL
CEMENT SLURRY
EXISTING PIPE/FITTING/STRUCTURE
EXISTING STORM WATER PIPE
EXISTING ELECTRICAL CONDUIT
1. THE CITY WILL FULLY DRAIN THE TANK PRIOR TO THE START OF THE PROJECT. MINOR RESIDUAL WATER (~2") MAY REMAIN AND SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO REMOVE.
2. THE CITY WILL MAINTAIN SERVICE TO CUSTOMERS FOR THE DURATION OF THE REHABILITATION EFFORT.
3. THE CONTRACTOR SHALL NOT OPERATE ANY VALVES.
4. THE COST OF WATER TO FILL THE TANK ONE TIME WILL BE COVERED BY THE CITY. ANY SUBSEQUENT FILLS OR WASTED WATER SHALL BE PAID FOR BY THE CONTRACTOR AT THE CITY'S STANDARD RATE.
5. PARKING IN FRONT OF HOMES DURING CONSTRUCTION IS NOT PERMITTED.
6. DELIVERIES SHALL BE ON A TRUCK BED NO LONGER THAN 20 FEET IN ORDER TO MAINTAIN EFFICIENT UNLOADING.
7. THE COUNTY OF SANTA CRUZ NOISE ORDINANCE (COUNTY CODE CHAPTER 8.30) PROHIBITS ANY NOISE THAT IS OFFENSIVE BETWEEN THE HOURS OF 8:00 AM AND 10:00 PM. THIS REQUIREMENT WILL BE STRICTLY ENFORCED DURING THE CONTRACT PERIOD. DURING THESE HOURS A NOISE IS AUTOMATICALLY CONSIDERED OFFENSIVE IF IT IS:
- CLEARLY DISCERNIBLE AT A DISTANCE OF 150 FEET FROM THE PROPERTY LINE.
- EXCEEDS 75 DECIBELS AT THE EDGE OF THE PROPERTY LINE.
8. THE CONTRACTOR SHALL MAINTAIN VEHICLE ACCESS TO THE SECOND TANK ON SITE FOR CITY OPERATIONS STAFF.
STAGING AND STORAGE AREA
STEEL BEARING SURFACE
NOTES, SYMBOLS, ABBREVIATIONS,
LEGEND, AND PROJECT SUMMARY
G-2 2 6
8' (TYP)
2 (TYP OF 3)
EX. 8" WATER LINE
EX. 24" STEEL PIPE
EX. 18" SEWER MAIN
EX. ELECTRICAL
PULL BOXES
EX. ELECTRICAL
PULL BOXES
EX. ELECTRICAL
PULL BOXES
EX. ELECTRICAL
PULL BOXES
EX. 12" PVC
EX. DRAIN
STRUCTURE
EX. 12" STORM
DRAIN
EX. SDMH
EX. STORM DRAIN
CATCH BASIN
EX. 10"
WATER LINE
EX. SSMH
EX. 8" WATER LINE
EX. RESERVOIR B
EX. RESERVOIR A
EX. 24" WATER LINE
EX. SITE
FENCE
150'-0" DIAMETER
82°
22°
CONTRACTOR STORAGE
AND STAGING AREA
1" T
YP
4"
2"
4"
2" DIA.
TIE-OFF LUG TO BE 3/8" THICK
TOP OF TANK SHELL
WELD1/4"
NOTE: COAT FALL PROTECTION ANCHOR POINT AND DAMAGED EXISTING
EXTERIOR TANK COATING PER SPECIFICATIONS
CITY OF WATSONVILLE, CALIFORNIA
PUBLIC WORKS, ENGINEERING DEPARTMENT
APPROVED: DATE
MARIA ESTHER CARRANZA RODRIGUEZ, CITY ENGINEER
DESIGN: JAA
CHECKED: TNH
SCALE: AS SHOWN
JOB No. CIWAT.230372.03
REV. No. DATE REVISION DESCRIPTION BY
SCALE IS IN INCHES
FOR REDUCED PLANS ORIGINAL 43210
XX-XX-XXXX
C:
\B ox \P ro je ct s\
CI
W
AT
W at so nv ille
\C
IW
AT
.2
2.
A irp or t R es R eh ab
\5 E ng
CA
D\
Sh ee ts
\C ivi l P la n.
dw g W ed
7.
M ay .2
0:
:3
AM b y:
Jo na th an
M aa s
OF
800/811-642-2444
TOLL FREEUSACALL
TWO DAYS BEFORE YOU DIG
AIRPORT TANK REHABILITATION PROJECT
2025 Gateway Place, Suite 328 San Jose, CA 95110
805-692-6921 | www.mnsengineers.com
SITE PLAN
BLAST, REPAIR, AND COAT TANK INTERIOR
SURFACES PER SPECIFICATIONS.
INSTALL FALL PROTECTION TIE-OFF ANCHORS
PER DETAIL 1, THIS DRAWING. COAT TIE-OFF
ANCHORS.
REMOVE, DISASSEMBLE, REPAIR, RE-COAT, AND
RE-INSTALL EXISTING 48"Ø ROOF VENT WITH
STAINLESS STEEL FASTENERS.
SEE STRUCTURAL SHEETS FOR STEEL TANK
REPAIRS.
BLAST, REPAIR, AND RECOAT TANK EXTERIOR
PER SPECIFICATIONS. THIS IS AN ADD/
ALTERNATE ITEM, TO BE EXERCISED AT BID
AWARD.
0'20' 20'10'10'
SCALE: 1" = 20'
0'
FALL PROTECTION ANCHOR POINT DETAIL
SCALE: 1" = 1/4'
CONSTRUCTION NOTES
AIRPORT TANK SITE PLAN AND DETAILS
C-1 3 6
STRUCTURAL NOTES
S-1 4
GENERAL NOTES
1. The following notes, typical details and schedules shall apply to all phases of this project unless otherwise shown or noted.
2. Specific notes and details shall take precedence over general notes and typical details.
3. All materials and workmanship shall conform to the minimum standards of the current AWWA D100 and such other regulating agencies exercising authority over any portion of the work.
4. The Construction Documents shall consist of these notes, details, schedules, plans, drawings, and Specifications.
5. All specifications, including but not limited to materials and products, shall be those put forth in the Construction Documents. No substitutions shall be permitted to be used or assumed to be used in the bidding or construction process without written approval by the Engineer of Record.
6. The contractor shall examine the Construction Documents and shall notify the Engineer of Record of any discrepancies they may find before proceeding with the work.
7. All information on existing conditions shown on drawings are based on best present knowledge available, but without guarantee of accuracy. The Contractor shall verify and be responsible for all dimensions and conditions at the site and shall notify the Engineer of Record of any discrepancies between actual site conditions and information shown on or in the Construction Documents before proceeding with work.
8. The Contractor shall immediately notify the Engineer of Record of any condition which in their opinion might endanger the stability of the structure or cause distress of the structure.
9. The Contractor shall provide temporary bracing and shoring for all structural members as required for structural stability of the structure during all phases of construction.
10. All work shall conform to the best practice prevailing in the various trades comprising work.
The Contractor shall be responsible for coordinating the work of all trades.
11. These Construction Documents represent the finished structure, and do not indicate the method of construction. The Contractor shall supervise and direct the work and shall be solely responsible for construction means, methods, techniques, sequences and procedures.
12. The Contractor shall take all steps necessary to ensure proper alignment of the structure after the installation of all structural and finish materials.
13. These notes, details, drawings and Specifications (Construction Documents) do not carry necessary provisions for construction safety. These documents and all phases of construction are to be governed, at all times, by applicable provisions of the current California Occupational Safety and Health Act.
14. Where any conflict occurs between the requirements of federal, state and local laws, codes, ordinances, rules and regulations, the most stringent shall govern.
16. The Contractor shall refer to the Specifications for information not covered by these drawings and General Notes.
17. Observation visits to the project site by field representatives of the Engineer of Record (support services) shall not include inspections of safety or protective measures, nor construction procedures, techniques or methods. Any support services performed by Engineer of Record during any phase of construction, shall be distinguished from continuous and detailed inspection services (as required by any regulating governmental agency, e.g.
the Authority Having Jurisdiction) provided by others. These support services, whether of material or work, are performed solely for the purpose of assisting in quality control and in achieving conformance with contract documents, but do not guarantee Contractor's performance and shall not be construed as supervision of construction.
18. Provide openings and supports as required per typical details and notes for mechanical, plumbing, and electrical equipment, vents, ducts, piping, etc. All mechanical, plumbing and electrical equipment shall be properly braced against lateral forces.
19. Refer to drawings by other disciplines to coordinate with Structural Drawings. Any discrepancy between these drawings shall be referred to the Engineer of Record for clarification prior to the start of construction.
20. Written dimensions shall have precedence over scaled dimensions.
21. Drawings (notes, schedules, details and plans) shall have precedence over Structural Calculations.
22. In the event that certain features of the construction are not fully shown on the drawings or called for in the General Notes or Specifications, their construction shall be of the same character as for similar conditions that are shown or called for.
23. ASTM designation and all standards refer to the latest amendments.
24. These structural Construction Documents shall not be modified without prior written approval of the Engineer of Record.
25. Only structural working drawings approved by the Authority Having Jurisdiction are permitted to be used for construction on this project. All other drawings or documents are obsolete and are not permitted on the job site, nor shall they be used for any construction purposes.
Contractors using unapproved drawings or documents are solely responsible for all work not performed in accordance with the "approved" drawings.
STRUCTURAL NOTES
DEMOLITION
1. Safety Note:
A. It is solely the Contractor's responsibility to comply with the pertinent sections of the
Construction Safety Orders issued by the State of California, latest edition, and all OSHA Requirements.
B. The Engineer of Record does not accept any responsibility for the Contractor's failure to comply with these requirements.
C. The Contractor shall be responsible for adequate design and construction of all forms.
Forms shall be adequately braced and shored.
2. Shore beams where necessary to maintain the structural integrity of the existing structure.
4. The Contractor is responsible for the design and location of all shoring.
5. Notify the Engineer of Record of any discrepancies between the plans and existing structure.
6. When saw cutting concrete or masonry, care shall be taken not to overcut or damage reinforcing bars.
STRUCTURAL STEEL AND WELDING
1. All structural steel construction shall conform to AISC 360-16 and AISC 341-16.
A. All structural steel shall be fabricated in an approved fabrication shop. Inspection and approval of fabrication shops shall conform to CBC Section 1704.2.5.
2. All structural steel shall conform to the following specifications:
3. Special Inspection shall be provided for all structural steel and welding.
4. All structural steel shall be fabricated, erected and welded in accordance with AISC Specifications for Structural Steel Buildings (AISC 360-16) and Code of Standard Practice for Steel Buildings and Bridges (AISC 303-16).
5. All welding shall be performed by welders with current AWS certification for weld procedures used.
6. Shop drawings for the fabrication of structural steel shall be submitted to Engineer of Record for their review, prior to fabrication.
7. No holes other than those specifically detailed shall be allowed through structural steel members. Burning of holes is not permitted.
8. All bolts shall conform to ASTM A325, unless noted or detailed otherwise.
9. All welding shall conform to AWS D1.1 and D1.8 specifications for welding. (E-70XX Electrodes).
10. Where fillet weld size is not indicated, use AWS minimum size, as specified in AISC Specifications for Structural Steel Buildings (AISC 360-16), Section J2.2.
11. All butt welds to be complete joint penetration, unless noted otherwise.
12. Welder qualification requirements, welding procedure and welding electrodes for all structural steel shall conform to CBC Sections 1705.2 and 2204.1.
Steel Shape ASTM Specificaiton Min. Yield Stress, Fy (ksi)
Angle, Channel A36 36
Plates, Bars, Rounds A36 36
Wide Flange A992 50
Pipe A53, Grade B 35
HSS Tube A500, Grade B 46
HSS Round A500, Grade B 42
A.B. Anchor Bolt ABV. Above ACI American Concrete Institute ADD'L Additional ADJ. Adjacent AHJ Authority Having Jurisdiction AISC American Institute of Steel
Construction APPROX. Approximate(ly) ASCE American Society of Civil
Engineers ASTM American Society of Testing and Materials ATR All Thread Rod AWS American Welding Society
BLDG. Building BM. Beam B.O. Bottom of BOT. Bottom BRG. Bearing b/t Between
CAC California Administrative Code CANT. Cantilever CBC California Building Code CJP Complete Joint Penetration CL. Centerline CLR. Clear COL. Column CONC. Concrete CONN. Connection CONST. Construction CONT. Continue, Continuous
Ø Diameter DBL. Double DCW Demand Critical Weld DET. Detail DEMO Demolition DL Dead Load DWGS. Drawings
EA. Each E.F. Each Face ELEC. Electric, Electrical ELEV. Elevation EMBED. Embedded, Embedment EOR Engineer of Record EQUIP. Equipment E.S. Each Side E.W. Each Way
(E) Existing EXP. Expansion EXT. Exterior
FAB. Fabricated FDN. Foundation F.F. Finish floor FLR. Floor F.O. Face of FRMG. Framing FT. Foot,Feet FTG. Footing
GA. Gauge GALV. Galvanized
HORIZ. Horizontal HSS Hollow Steel Section
HT. Height
IBC International Building Code ICC International Code Council ID Inside Diameter IN. Inch, Inches INT. Interior ksi Kips per Square Inch
LL Live Load
MAX. Maximum MB Machine Bolt MECH. Mechanical MFR. Manufactured, Manufacturer MIN. Minimum MPH Miles per Hour MTL. Metal
(N) New N.T.S. Not to Scale o.c. On Center o/ Over OD Outside Diameter
PEN. Penetration PL. Plate PJP Partial Joint Penetration psi Pounds per Square Inch PSF Pounds per Square Foot PERF. Perforated PW Puddle Weld
REBAR Reinforcing Bar REINF. Reinforcement RET. Retaining REQ'D Required
S.F. Square Feet SIM. Similar SMS Sheet Metal Screw SQ. Square STAGG'D Staggered STD. Standard STL. Steel SEOR Structural Engineer of Record
T&B Top and bottom THR'D Threaded T.O. Top of TYP. Typical
U.N.O. Unless Noted Otherwise
VERT. Vertical VIF Verify in Field w/ With WT. Weight
ABBREVIATIONS
GENERAL NOTES
1. All Special Inspection shall be provided in accordance with CBC Section 1704 and 1705.
2. Where Special Inspection is required, all inspection or testing shall be provided by an "approved agency" in accordance with CBC Section 1702.1, 1703.1 and 1704.1.
3. Special Inspectors shall keep records of inspections. The Special Inspector shall furnish inspection reports to the Authority Having Jurisdiction, and to the Engineer of Record. Reports shall indicate that work inspected was done in conformance to approved construction documents. Discrepancies shall be brought to the immediate attention of the contractor for correction. If the discrepancies are not corrected, the discrepancies shall be brought to the attention of the Authority Having Jurisdiction and to the Engineer of Record prior to the completion of that phase of work. A final report documenting required Special Inspections and correction of any discrepancies noted in the inspections shall be submitted at a point in time agreed upon by the permit applicant and the Authority Having Jurisdiction prior to the start of work.
4. Special Inspectors shall be approved by local Authority Having Jurisdiction in accordance with CBC Section 1704.2.1.
5. Local Authority Having Jurisdictions may require Special Inspection for "Special Cases" in accordance with CBC Section 1705.1.1
6. Refer to Special Inspection requirements by other disciplines not included herein.
SPECIAL INSPECTION
STEEL CONSTRUCTIONab
Verification and Inspection
C on t.
Pe rio di c
Required verification and inspection of steel construction
1. Material verification of structural steel, cold-formed steel deck, high-strength bolts, nuts and washers:
a. For structural steel, identification markings to conform to AISC 360, or ASTM Standards Specified in approved Construction Documents. Manufacturer's certificate of compliance required.
2. Material verification of structural steel:
a. Identification markings to conform to ASTM standards specified in the approved construction documents.
b. Manufacturer's certified test reports.
3. Material verification of weld filler materials:
a. Identification markings to conform to AWS specification in the approved Construction Documents
b. Manufacturer's certificate of compliance required
4. Inspection of welding:
a. Structural steel and cold formed steel deck:
1) Complete and partial joint penetration groove welds
2) Multi-pass fillet welds
3) Single-pass fillet welds > 516"
4) Single-pass fillet welds < 516"
Inspection tasks prior to welding
1. Welder qualification records and continuity records
2. Welding procedure specifications (WPSs) available
3. Manufacturer certifications for welding consumables available
4. Material identification (type/grade)
5. Welder identification systemc
6. Fit-up of groove welds (including joint geometry):
Joint preparation, dimensions, cleanliness, tacking, backing type and fit
8. Fit-up of fillet welds:
Dimensions, cleanliness, tacking
9. Check welding equipment
Inspection tasks during welding
1. Control and handling of welding consumables:
Packaging, exposure control
2. No welding over cracked tack welds
3. Environmental conditions:
Wind speed within limits, precipitation and temperature
4. WPS followed:
Settings on welding equipment, travel speed, selected welding materials, shielding gas type/flow rate, preheat applied, interpass temperature maintained min./max.), proper position (F, V, H, OH)
5. Welding techniques:
Interpass and final cleaning, each pass within profile limitations
Inspection tasks after welding
1. Welds cleaned
2. Size, length and location of welds
3. Welds meet visual acceptance criteria:
Crack prohibition, weld/base-metal fusion, crater cross section, weld profiles, weld size, undercut, porosity
4. Arc strikes
5. Repair activities
6. Document acceptance or rejection of welded joint or member
7. No prohibited welds have been added without the approval of the
EOR
CITY OF WATSONVILLE, CALIFORNIA
PUBLIC WORKS, ENGINEERING DEPARTMENT
APPROVED: DATE
MARIA ESTHER CARRANZA RODRIGUEZ, CITY ENGINEER
DESIGN: JMK
CHECKED: MEP
SCALE: AS SHOWN
JOB No. CIWAT.230372.03
REV. No. DATE REVISION DESCRIPTION BY
SCALE IS IN INCHES
FOR REDUCED PLANS ORIGINAL 43210
XX-XX-XXXX
F:
\2
5-
\0
3-
BI
M \0
6-
CA
D\
D ra wi ng s\
-0
- S -1
.d wg
Tu e
.M ar .2
2:
:0
PM
b y:
J os ep h Kl im cz yk
OF
800/811-642-2444
TOLL FREEUSACALL
TWO DAYS BEFORE YOU DIG
AIRPORT TANK REHABILITATION PROJECT
111 N. Market Street, Suite 440 San Jose, CA 95113
408-610-4202 | www.mnsengineers.com E
R H
P
R M I
C AEL E . PAROL I NI
No. 5405
S T UC T URA LS T A T O F C A L I F OR N I A
EG
I S T
ERED ROF ESS I ONA L ENG I NEER
605-27-2026
811 EL CAPITAN WAY, SUITE 240
SAN LUIS OBIPSO, CA 93401 | 805 439 2110
Notes: Steel Construction
a. CBC Section 1705.2 and AISC 360 Chapter N
b. CBC Section 1705.13.1 and AISC 341 Chapter J
c. The fabricator or erector, as applicable, shall maintain a system by which a welder who has welded a joint or member can be identified. Stamps, if used, shall be the low-stress type.
(E) COLUMN AND BASE
PLATE, TYP. OF 7
(E) CENTER COLUMN
AND BASE PLATE
(E) FLOOR PLATE
(E) TANK SHELL
(E) RING WALL
FOOTING
(E) LADDER AND
CAGE
(E) MANWAY
(E) MANWAY
(E) OVERFLOW
75'-0"75'-0"
37'-6"
(E) CHANNEL RAFTER
(E) CHANNEL RAFTER
(E) WIDE FLANGE GIRDER
(E ) W
ID
E
FL
AN
G E
G
IR
D
ER
(E) W
IDE FLANGE GIRDER
(E) WIDE FLANGE GIRDER
(E ) W
ID
E
FL
AN
GE
GIR
DER
(E) W
ID
E FLAN
G
E G
IR
D
ER
(E) WIDE FLANGE GIRDER
(E) CENTER COLUMN,
DOLLAR PLATE, AND VENT
(E) ROOF HATCH
(E) TANK SHELL
(E) BENT RAFTER SHEAR TAB,
LOCATION SHOWN APPROXIMATE
VERIFY TOTAL QUANTITIES IN FIELD
(E) BOWED RAFTER,
VERIFY LOCATIONS AND
QUANTITIES IN FIELD
(E) ROOF PLATE
(E) LADDER AND
CAGE
(E) OVERFLOW
CITY OF WATSONVILLE, CALIFORNIA
PUBLIC WORKS, ENGINEERING DEPARTMENT
APPROVED: DATE
MARIA ESTHER CARRANZA RODRIGUEZ, CITY ENGINEER
DESIGN: JMK
CHECKED: MEP
SCALE: AS SHOWN
JOB No. CIWAT.230372.03
REV. No. DATE REVISION DESCRIPTION BY
SCALE IS IN INCHES
FOR REDUCED PLANS ORIGINAL 43210
XX-XX-XXXX
F:
\2
5-
\0
3-
BI
M \0
6-
CA
D\
D ra wi ng s\
-0
- S -2
.d wg
Tu e
.M ar .2
2:
:2
PM
b y:
J os ep h Kl im cz yk
OF
800/811-642-2444
TOLL FREEUSACALL
TWO DAYS BEFORE YOU DIG
AIRPORT TANK REHABILITATION PROJECT
111 N. Market Street, Suite 440 San Jose, CA 95113
408-610-4202 | www.mnsengineers.com E
R H
P
R M I
C AEL E . PAROL I NI
No. 5405
S T UC T URA LS T A T O F C A L I F OR N I A
EG
I S T
ERED ROF ESS I ONA L ENG I NEER
605-27-2026
811 EL CAPITAN WAY, SUITE 240
SAN LUIS OBIPSO, CA 93401 | 805 439 2110
TANK FOUNDATION AND ROOF FRAMING PLAN
S-2 5
(VERIFY ALL DIMENSIONS WITH EXISTING CONDITIONS)
TANK ROOF PLAN
SCALE: 3/32" = 1'-0" (VERIFY ALL DIMENSIONS WITH EXISTING CONDITIONS)
TANK BOTTOM PLAN
SCALE: 3/32" = 1'-0"
TANK REPAIR NOTES:
1. AFTER REMOVAL OF COATINGS THE CONDITION OF THE FOLLOWING ELEMENTS
SHALL BE REVIEWED BY THE E.O.R.. IF EXTENSIVE SECTION LOSS IS
OBSERVED, SEE REPAIR DETAILS:
· TANK SHELL SEE 1/S-3
· TANK SHELL BOTTOM SEE 2/S-3
· TANK BOTTOM SEE 3/S-3
· TANK ROOF PLATE SEE 5/S-3
· RAFTER TO SHELL CONN. SEE 6/S-3
· TANK RAFTERS SEE 7/S-3
2. SEE 9/S-3 FOR SEALANT AT RAFTER TO ROOF PLATE, ADD ALTERNATE BID ITEM.
3. SECTION LOSS AT SHELL JOINT WELDS SHALL BE REMOVAL AND
REPLACEMENT OF WELD MATERIAL.
4. FOR PERMISSIBLE SWEEP IN RAFTERS, SEE 4/S-3. ADD SUPPLEMENTARY
RAFTERS AS REQUIRED AT LOCATIONS WHERE SWEEP EXCEEDS THE
ALLOWABLE. SEE 6/S-3 AND 8/S-3 FOR RAFTER REPLACEMENT ATTACHMENTS.
MINIMUM PLATE THICKNESS - FOR REFERENCE:
ULTRASONIC TESTING OF PLATE MATERIAL SHALL BE PERFORMED
TO DETERMINE BASE METAL THICKNESS.
THICKNESS LESS THAN NOTED BELOW SHALL BE REINFORCED WITH
REINFORCING PLATE OR DEPOSITION OF FILLER METAL AS SHOWN
IN DETAILS ON S-3.
DETERMINATION OF SECTION LOSS SHALL BE MADE BY THE
PROJECT SPECIAL INSPECTOR OR API 653 INPSECTOR.
SHELL
COURSE 1: (BOTTOM) T =0.75"
COURSE 2: T = 0.50"
COURSE 3: (TOP) T = 0.3125"
BOTTOM
T =0.25"
ROOF
T =0.1875"
KNUCKLE
T =0.25"
NOTES: (#)
1. IN AREAS OF STEEL SECTION LOSS EXCEEDING 10% OF THE ORIGINAL MATERIAL THICKNESS, GRIND AREA SMOOTH AND REPLACE WITH WELD METAL TO RESTORE
MATERIAL BACK TO INITIAL THICKNESS. SECTION LOSS FOR AREAS EXCEEDING 4in2 SHALL RECEIVE LAP WELDED PATCH PLATE PER DETAIL ABOVE.
2. ALL WELD INTERSECTIONS SHALL BE AT APPROXIMATELY 90°.
3. PRIOR TO WELDING NEW VERTICAL JOINTS, CUT EXISTING HORIZONTAL WELD FOR A MINIMUM OF 12in. BEYOND THE NEW VERTICAL JOINTS. WELD THE HORIZONTAL JOINT
LAST.
4. PRIOR TO WELDING NEW VERTICAL JOINTS, CUT EXISTING SHELL-TO-BOTTOM PLATE WELDS BEYOND THE NEW VERTICAL JOINTS. THE CUT SHALL EXTEND PAST OR STOP
SHORT OF EXISTING BOTTOM PLATE WELDS BY AT LEAST 3in. OR 5t. WELD THE SHELL-TO-BOTTOM WELD LAST.
5. t = SHELL WALL THICKNESS
6. REPAIR PLATE THICKNESS SHALL MATCH EXISTING SHELL THICKNESS.
R
A
A
SEE NOTE 3 SEE NOTE 3
V
V
V
G R
EA
TE
R O
F R
O R
H
EXISTING WELDS
AS INDICATED BY
DASH
R
V
H H
B
R
R
CC
B
WELD JOINT
SEE
NOTE 4
SEE
NOTE 4
SEE
NOTE 4
MINIMUM WELD SPACING BETWEEN EDGES (TOES) OF
WELDS FOR THICKNESS OF REPLACEMENT SHELL
PLATE, t
DIMENSION t < 0.5" t > 0.5"
R 6" GREATER OF 6" OR 6t
B 6" GREATER OF 10" OR 8t
H 3" GREATER OF 10" OR 8t
V 6" GREATER OF 10" OR 8t
A 12" GREATER OF 12" OR12t
C GREATER OF 3" OR 5t
CORRODED
AREA
2" M
IN
1' -0
" M
IN
NOTES:
1. SEE REPAIR NOTES ON 1/S-3.
2. FOR PITTING DEPTH EXCEEDING 30%xTSHELL PLACE REINFORCING PUDDLE WELD
IN (E) SHELL.
TSHELL
T PER PLAN
T
T
(E) SHELL
8" REPAIR PLATE
THICKNESS
PITTING IN (E) SHELLV.
I.F
1'
-0 " M
IN
(E) SHELL BOTTOM
REPAIR PLATE
SPLICEINSIDE OF TANK
OUTSIDE OF TANK
NOTES:
1. DIMENSIONS GIVEN ARE FROM TOE OF FILLET WELDS OR TO CENTERLINE OF BUTT WELD AND ALSO APPLY TO NEW-TO-EXISTING WELDS.
2. MINIMUM DISTANCE BETWEEN TWO WELDED ON PATCH PLATES IN THE CRITICAL ZONE SHALL BE ONE HALF OF THE LESSER OF L1 OR L2.
3. THE MAXIMUM DIMENSIONS ALONG THE SHELL FOR WELDED-ON PATCH PLATE IN THE CRITICAL ZONE IS 24-INCHES.
4. WHEN THE EDGE OF A WELDED-ON PATCH PLATE IS APPROXIMATELY PARALLEL TO A BOTTOM SEAM, THE EDGE SHALL BE HELD AT LEAST 2 INCHES
FROM WELD SEAM.
5. PATCHES OVER THREE-PLATE LAPS SHALL EXTEND 12 INCHES MINIMUM BEYOND THE THREE-PLATE LAP.
6. THESE RULES APPLY TO BUTT WELDED BOTTOMS.
7. TANK BOTTOM REPAIR SHALL FOLLOW API 653 SECTION 9.11.1.1 AND 9.11.1.2.
8. CRACKS, GOUGES, TEARS, AND CORRODED AREAS OUTSIDE THE CRITICAL ZONE MAY BE REPAIRED BY DEPOSITION OF WELD METAL. THE REPAIRED
AREA SHALL BE TESTED USING MAGNETIC PARTICLE METHOD OR LIQUID PENETRANT METHOD OR OTHER APPROVED TESTING METHOD.
9. NOTIFY EOR FOR REPAIRS REQUIRED IN THE CRITICAL ZONE.
L1 SEE NOTE 3
2" MIN.
SEE NOTE 2 L2 SEE NOTE 3
6" M
IN
4" MIN.
2" M
IN
1' -0
" M
IN
2" M
IN.
1'-0" MIN.
1'- 0"
M
IN
TY
P.
1'-0" MIN.
2" MIN.
2" MIN.
2" M
IN.
R2" TYP.
PATCH PLATE
THICKNESS, t, TO MATCH
(E) FLOOR PLATE
THICKNESS. 14" MIN.
TYP.
t
45° or 90°
SHELL
PLATE
A
A
SECTION A-A
SHELL
PLATEWELDED ON PATCH
PLATE
(14" MAX. IN CRITICAL
ZONE)
TANK BOTTOM
PLATE
3" CRITICAL ZONE
THREE PLATE
LAP, SEE NOTE
BOTTOM SEAM
4" M
IN.
CORRODED
AREA, WHERE
OCCURS
2" M
IN
TY
P.
6" M
IN
1'-0" M
IN.
GREATER OF 3"
OR 5x SHELL
THICKNESS
NOTES: (#)
1. MEASURE ENDS OF ALL EXISTING CHANNELS TO DETERMINE SWEEP DIMENSION
RELATIVE TO STRAIGHT LINE.
2. ADD SUPPLEMENTAL RAFTERS WITHIN 12" WHERE SWEEP EXCEEDS ALLOWABLE
NOTED IN DETAIL.
ALLOWABLE SWEEP
2"
PLAN VIEW OF (E) RAFTER
(E) CHANNEL RAFTER
NOTES:
1. TYPICAL TANK ROOF = 14"
2. WHERE PITTING AREA IS LESS THAN 2 in2 DEPOSIT WELD FILLER TO REPAIR
CORROSION.
2" M
IN
ROOF PLATE JOINT
ROOF CORRODED
AREA
PL. 14"
SEE NOTE 2
2" M
IN
R2"
1' -0
" M
IN
(E) KNUCKLE
(E) RAFTERRAFTER TO
ROOF 3
16 2"
T.O.
SHELL
3"
(N) C8x11.5
NOTES: (#)
1. WHERE EXISTING RAFTER CONNECTION PLATE IS CORRODED OR BENT, REMOVE
AND PROVIDE NEW CHANNEL CONNECTION.
NOTES:
1. ALTERNATE OPTION: IT IS ACCEPTABLE TO REPLACE RAFTER IN ITS ENTIRETY IN
LIEU OF PROVIDING REPAIR PLATE.
(E) CHANNEL RAFTER
CORROSION IN RAFTER
RESULTING IN FLANGE
WIDTH LESS THAN 80%bf
(N) PL. 14"x3"
(E) CHANNEL RAFTER
(N) PL. 14"x3"
A
A
SECTION A-A
ELEVATION
4" 4"
CORRODED
SECTION
CORROSION IN RAFTER
RESULTING IN FLANGE
WIDTH LESS THAN 13
4 " bf
NOTES: (#)
1. CONTRACTOR SHALL SUBMIT PROPOSED PRODUCT FOR REVIEW BY E.O.R.
(E) RAFTER
(E) ROOF PLATE
NSF61 SEALANT BETWEEN
ROOF PLATE AND RAFTER.
PRODUCT SHALL BE
COMPATIBLE WITH COATING
SYSTEM (1)
(E) FILLET AT ROOF
PLATE JOINT
NSF61 SEALANT AT
ROOF PLATE JOINT,
WHERE FILLET WELDS
ARE NOT PROVIDED
(E) RAFTER
NOTES: (#)
1. WHERE EXISTING RAFTER CONNECTION PLATE IS CORRODED OR BENT, REMOVE
AND PROVIDE NEW CHANNEL CONNECTION.
TOP OF (E) WF OR
DOLLAR PLATE
4"
11 2" 3"
2"
PL. 3 8" w/ (2) A325
BOLTS
CITY OF WATSONVILLE, CALIFORNIA
PUBLIC WORKS, ENGINEERING DEPARTMENT
APPROVED: DATE
MARIA ESTHER CARRANZA RODRIGUEZ, CITY ENGINEER
DESIGN: JMK
CHECKED: MEP
SCALE: AS SHOWN
JOB No. CIWAT.230372.03
REV. No. DATE REVISION DESCRIPTION BY
SCALE IS IN INCHES
FOR REDUCED PLANS ORIGINAL 43210
XX-XX-XXXX
F:
\2
5-
\0
3-
BI
M \0
6-
CA
D\
D ra wi ng s\
-0
- S -3
.d wg
Tu e
.M ar .2
2:
:5
PM
b y:
J os ep h Kl im cz yk
OF
800/811-642-2444
TOLL FREEUSACALL
TWO DAYS BEFORE YOU DIG
AIRPORT TANK REHABILITATION PROJECT
111 N. Market Street, Suite 440 San Jose, CA 95113
408-610-4202 | www.mnsengineers.com E
R H
P
R M I
C AEL E . PAROL I NI
No. 5405
S T UC T URA LS T A T O F C A L I F OR N I A
EG
I ST
ERED ROF ESS I ONA L ENG I NEER
605-27-2026
811 EL CAPITAN WAY, SUITE 240
SAN LUIS OBIPSO, CA 93401 | 805 439 2110
TYPICAL REPAIR DETAILS
S-3 6
S-3
SHELL PLATE MATERIAL REPAIR
N.T.S.
S-3
N.T.S.
N.T.S.
S-3
SHELL BOTTOM REPAIR
N.T.S.
S-3
ALLOWABLE RAFTER SWEEP
N.T.S.
TANK BOTTOM REPAIR
S-3
ROOF PLATE REPAIR
N.T.S.
S-3
RAFTER TO SHELL
N.T.S.
S-3
RAFTER REPAIR
N.T.S.
S-3
RAFTER TO WF. OR DOLLAR PL.
N.T.S.
S-3
RAFTER SEALANT
N.T.S.
0.1875"
| Sheets and Views |
| 1 TITLE SHEET, SHEET INDEX, VICINITY MAP, AND LOCATION MAP |
| 2 NOTES, SYMBOLS, ABBREVIATIONS, LEGEND, AND PROJECT SUMMARY |
| 3 AIRPORT TANK SITE PLAN AND DETAILS |
Final Plan Markup
File details come from the government source that posted it. Updated .