This is a Limited Asbestos Inspection and Lead-Based Paint Survey report prepared by Hill West Environmental for the State of Utah Department of Administrative Services, Division of Facilities Construction and Management (DFCM), regarding mechanical upgrades at the Ogden Driver's License Division located at 615 East 5300 South, Ogden, Utah 84405. The inspection was conducted on June 9, 2026, by certified inspector Claude Dahlk (CHMM, CIEC, ASB-0433) to identify asbestos-containing materials (ACM) and lead-based paint components that would be impacted during the planned renovation. The survey focused exclusively on areas affected by the mechanical upgrade project, including roof core and black baseboard materials. Six samples were collected and analyzed using polarized light microscopy (PLM) testing by Eurofins Aerotech Built Environment Testing, LLC, with analytical results received on June 16, 2026.

The inspection findings determined that no asbestos-containing materials were detected in any of the six samples collected, and no lead-based paint materials would be impacted during the project, therefore no lead samples were collected. Additionally, no universal, hazardous, or toxic wastes were identified that would be impacted during the renovation activities. The report specifies that contractors must cease work and notify DFCM immediately if they discover suspect materials not included in this survey. This limited inspection was conducted in compliance with Utah Division of Air Quality, Utah Occupational Safety and Health Administration (UOSHA), and Salt Lake Valley Health Department (SLVHD) regulations. The scope is limited to the specific renovation areas and does not represent an exhaustive hazard assessment of the entire facility.

View the file

Other files

File Type Posted
2-1-CS27022-27075550-Solicitation.pdf PDF
3-2-CS27022-27075550-Approved Plans.pdf PDF

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

LIMITED ASBESTOS INSPECTION

AND LEAD-BASED PAINT SURVEY

Ogden Driver’s License Division

615 East 5300 South Ogden, Utah 84405

Mechanical Upgrades

July 8, 2026

Prepared for:

Ms. Aubrey Stapel

Project Manager, Statewide Programs

State of Utah

Department of Administrative Services

Division of Facilities Construction and Management (DFCM)

Taylorsville State Office Building

4315 South 2700 West, 3rd Floor

Taylorsville, Utah 84129-2128

Prepared by:

Hill West Environmental

7963 Douglas Drive

Park City, Utah 84098

State of Utah Company Certification # ASBC-495

Claude Dahlk, CHMM, CIEC

(801) 450-8060

EXECUTIVE SUMMARY

On June 9, 2026, Hill West Environmental conducted a limited pre-renovation inspection for asbestos and lead-based paint at Ogden Driver’s License Division located at 615 East 5300 South, Ogden, Utah 84405. The project includes mechanical upgrades of the Ogden Driver’s License Division.

Ms. Aubrey Stapel, Project Manager with the State of Utah, Division of Facilities Construction and Management (DFCM) requested this inspection to identify asbestos-containing materials (ACM) and building components with lead-based paint that need to be addressed before the building is renovated.

Suspect materials that will be impacted included roof core and black baseboard.

Areas in which renovations are to occur were inspected, all other areas were not inspected as part of this survey. Hill West identified the following asbestos-containing materials (ACM) and lead-based paint during this inspection:

Asbestos-Containing Materials

Homogeneous Area Number

Material Description

Asbestos Content

Amount

Cost Estimate

N/A No asbestos materials were identified in the samples collected during this inspection.

N/A N/A N/A

Building Components with XRF Lead readings ≥ 0.4 mg/cm2

Material Type Reading (mg/cm2)

No Lead materials will be impacted during this project and therefore no samples were collected

N/A

Universal, Hazardous, and Toxic Wastes

Material Type Quantity

No Universal, Hazardous, and Toxic Wastes will be impacted during this renovation project. N/A

Conclusions

ACM – Asbestos Containing Materials (ACM) were not detected within any of the suspect building materials that were tested within the project area.

If the renovation or demolition contractor discovers additional suspect building materials that were not sampled as part of this inspection, they shall stop working and notify DFCM so that the materials can be sampled.

Lead – Lead materials will not be impacted during this renovation project and therefore, no samples were collected. If the contractor discovers other materials that will be impacted during this project that were not sampled, they shall stop work and alert DFCM that suspected materials require additional testing to determine if they are regulated.

Universal, Hazardous and Toxic Wastes – No Universal, Hazardous, and Toxic Wastes will be impacted during this renovation project.

1.0 INTRODUCTION

As per DFCM’s instructions, Hill West Environmental conducted a limited asbestos inspection of the Ogden Driver’s License Division located at 615 East 5300 South, Ogden, Utah 84405. Due to the remodel and upgrade projects, Hill West was instructed to only inspect areas that will be impacted during the renovation project.

The purpose of this survey was to identify the existence, extent, and condition of both friable and non-friable asbestos-containing materials (ACM) and lead-based paint within the renovation areas.

2.0 SITE VISIT /OBSERVATIONS

2.1 Asbestos Inspection

On June 9, 2026, Hill West Environmental visited the site to survey the renovation areas of the building. A complete asbestos inspection of the areas that will be impacted during renovations was made to determine conditions and develop a sampling scheme for the areas. Table 1 summarizes the asbestos inspection results.

Table 1 – Asbestos Materials

Homogenous Area Number

Material Description/Location Asbestos Content

Amount Cost Estimate

N/A No asbestos materials were identified in the inspection.

N/A N/A N/A

Appendix A contains photographs of samples.

Appendix B contains analytical results and certifications.

3.0 RESULTS

Table 3 summarizes the analytical results for the asbestos samples collected.

Table 3 – Asbestos Analytical Results

Sample Number

Homogeneous Area Number

Material Sampled Sample Location Estimated Quantity*

Analytical Results

OD – 01A M001 Roof Core Roof 50 ft2 None Detected

OD – 01B M001 Roof Core Roof 50 ft2 None Detected

OD – 01C M001 Roof Core Roof 50 ft2 None Detected

OD – 02A M002 Black Caulk Roof 20 ft2 None Detected

OD – 02B M002 Black Caulk Roof 20 ft2 None Detected

OD – 02C M002 Black Caulk Roof 20 ft2 None Detected

* Estimated Quantity is based on amount to be disturbed during the upgrade project.

4.0 DISCUSSION/CONCLUSTIONS

In Utah, EPA asbestos regulations are administered by the Utah Division of Air Quality. Utah Occupational Safety and Health Administration (UOSHA) has adopted the Federal OSHA regulations. In addition, the Salt Lake Valley Health Department (SLVHD) regulates demolition activities in Salt Lake County. The SLVHD regulations for pre-demolition building inspections require an asbestos inspection, but also require building owners to inspect the building for other hazardous materials such as universal wastes, hazardous and toxic wastes and lead-based paint. Similar to asbestos, these wastes, if present must be removed prior to demolition/renovation.

A copy of this report should be on-site during all renovation activities.

This limited asbestos and lead-based paint inspection was conducted at the Ogden Driver’s License Division that will be impacted during renovation activities.

Only items that are believed to be impacted during renovation activities were inspected during this survey. This survey is not intended to represent an exhaustive research into all asbestos or other hazards or conditions which may exist within other buildings located at this project site.

This report does not purport to represent future indoor conditions or events.

Situations or activities which transpire subsequent to this report, which result in adverse environmental, construction and/or engineering impacts, are not to be construed as relevant to this study.

This report is intended for the sole use of Hill West's client. This report may not be used or relied upon by any other party without the written consent of Hill West.

The scope of services performed in execution of the evaluation may not be appropriate to satisfy the needs of other users, and the use or re-use of this document or the findings, conclusions, or recommendations is at risk of said user. Appendix B contains all Company certifications and individual inspector certifications.

Prepared by:

Claude Dahlk, CHMM, CIEC Asbestos Inspector ASB-0433

Appendix A

Photographs of Samples

Ogden Drivers License Division

615 East 5300 South

Ogden, Utah

OD – 01A Roof Core

OD – 01B 12 Roof Core

OD – 01C Roof Core

OD – 02A Black Caulk

OD – 02B Black Caulk

OD – 02C Black Caulk

Appendix B

Analytical Results and Certifications

Approved by:

Approved Signatory Renee Luna-Trepczynski

Report for:

Claude Dahlk Hill West Environmental, LLC 7963 Douglas Drive Park City, UT 84098

Regarding:

Eurofins Aerotech Built Environment Testing, LLC Project: Ogden DPS; 615 East 5300 South, South Ogden, UT

EML ID: 4575324

All samples were received in acceptable condition unless noted in the Report Comments portion in the body of the report. The results relate only to the samples as received and tested. The results include an inherent uncertainty of measurement associated with estimating percentages by polarized light microscopy. Measurement uncertainty data for sample results with >1% asbestos concentration can be provided when requested.

Eurofins Aerotech Built Environment Testing, LLC ("the Company"), a member of the Eurofins Built Environment Testing group of companies, shall have no liability to the client or the client's customer with respect to decisions or recommendations made, actions taken or courses of conduct implemented by either the client or the client's customer as a result of or based upon the Test Results. In no event shall the Company be liable to the client with respect to the Test Results except for the Company's own willful misconduct or gross negligence nor shall the Company be liable for incidental or consequential damages or lost profits or revenues to the fullest extent such liability may be disclaimed by law, even if the Company has been advised of the possibility of such damages, lost profits or lost revenues. In no event shall the Company's liability with respect to the Test Results exceed the amount paid to the Company by the client therefor.

Dates of Analysis:

Asbestos PLM: 06-16-2026

Service SOPs: Asbestos PLM (EPA 40CFR App E to Sub E of Part 763 & EPA 600/R-93-116, EBET-PLM-SOP83921) NVLAP Lab Code 500031-0

EMLab ID: 4575324, Page 1 of 4Eurofins Aerotech Built Environment Testing, LLC

Eurofins Aerotech Built Environment Testing, LLC 1501 West Knudsen Drive, Phoenix, AZ 85027

(800) 651-4802 www.eurofinsus.com/BuiltClient: Hill West Environmental, LLC C/O: Claude Dahlk Re: Ogden DPS; 615 East 5300 South, South Ogden, UT

Date of Sampling: 06-09-2026 Date of Receipt: 06-11-2026 Date of Report: 06-16-2026

ASBESTOS PLM REPORT

Total Samples Submitted: 6 Total Samples Analyzed: 6

Total Samples with Layer Asbestos Content > 1%: 0

Location: OD-01A, Roof Core Lab ID-Version‡: 23055128-1

Sample Layers Asbestos Content White Non-Fibrous Material ND Gray/White Roof Flashing ND

Brown Roofing Felt 2 ND Yellow Foam ND

Brown Roofing Felt ND Composite Non-Asbestos Content: 3% Cellulose

2% Synthetic Fibers < 1% Glass Fibers

Sample Composite Homogeneity: Poor

Location: OD-01B, Roof Core Lab ID-Version‡: 23055129-1

Sample Layers Asbestos Content White Non-Fibrous Material ND Gray/White Roof Flashing ND

Brown Roofing Felt 2 ND Yellow Foam ND

Brown Roofing Felt ND Composite Non-Asbestos Content: 3% Cellulose

2% Synthetic Fibers < 1% Glass Fibers

Sample Composite Homogeneity: Poor

Location: OD-01C, Roof Core Lab ID-Version‡: 23055130-1

Sample Layers Asbestos Content Gray/White Roof Flashing ND

Composite Non-Asbestos Content: 5% Synthetic Fibers Sample Composite Homogeneity: Good

EMLab ID: 4575324, Page 2 of 4Eurofins Aerotech Built Environment Testing, LLC

The test report shall not be reproduced except in full, without written approval of the laboratory. The report must not be used by the client to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the federal government. The Company reserves the right to dispose of all samples after a period of thirty (30) days, according to all state and federal guidelines, unless otherwise specified.

All components not quantified as asbestos content and non-asbestos content are considered to be non-fibrous matrix components. Matrix components may include, but are not limited to, gypsum, paint, silicate minerals, vinyl, binder, calcium carbonate, tar, and foam.

Inhomogeneous samples are separated into homogeneous subsamples and analyzed individually. ND means no fibers were detected. When detected, the minimum detection and reporting limit is less than 1% unless point counting is performed. Floor tile samples may contain large amounts of interference material and it is recommended that the sample be analyzed by gravimetric point count analysis to lower the detection limit and to aid in asbestos identification.

‡ A "Version" indicated by -"x" after the Lab ID# with a value greater than 1 indicates a sample with amended data. The revision number is reflected by the value of "x".

(800) 651-4802 www.eurofinsus.com/BuiltClient: Hill West Environmental, LLC C/O: Claude Dahlk Re: Ogden DPS; 615 East 5300 South, South Ogden, UT

Date of Sampling: 06-09-2026 Date of Receipt: 06-11-2026 Date of Report: 06-16-2026

ASBESTOS PLM REPORT

Location: OD-02A, Black Caulk Lab ID-Version‡: 23055131-1

Sample Layers Asbestos Content Black Caulk ND

Sample Composite Homogeneity: Good

Location: OD-02B, Black Caulk Lab ID-Version‡: 23055132-1

Sample Layers Asbestos Content Black Caulk ND

Sample Composite Homogeneity: Good

Location: OD-02C, Black Caulk Lab ID-Version‡: 23055133-1

Sample Layers Asbestos Content Black Caulk ND

Sample Composite Homogeneity: Good

EMLab ID: 4575324, Page 3 of 4Eurofins Aerotech Built Environment Testing, LLC

The test report shall not be reproduced except in full, without written approval of the laboratory. The report must not be used by the client to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the federal government. The Company reserves the right to dispose of all samples after a period of thirty (30) days, according to all state and federal guidelines, unless otherwise specified.

All components not quantified as asbestos content and non-asbestos content are considered to be non-fibrous matrix components. Matrix components may include, but are not limited to, gypsum, paint, silicate minerals, vinyl, binder, calcium carbonate, tar, and foam.

Inhomogeneous samples are separated into homogeneous subsamples and analyzed individually. ND means no fibers were detected. When detected, the minimum detection and reporting limit is less than 1% unless point counting is performed. Floor tile samples may contain large amounts of interference material and it is recommended that the sample be analyzed by gravimetric point count analysis to lower the detection limit and to aid in asbestos identification.

‡ A "Version" indicated by -"x" after the Lab ID# with a value greater than 1 indicates a sample with amended data. The revision number is reflected by the value of "x".

(800) 651-4802 www.eurofinsus.com/BuiltClient: Hill West Environmental, LLC C/O: Claude Dahlk Re: Ogden DPS; 615 East 5300 South, South Ogden, UT

Date of Sampling: 06-09-2026 Date of Receipt: 06-11-2026 Date of Report: 06-16-2026

ASBESTOS PLM REPORT

PROJECT ANALYST AND SIGNATORY REPORT

Project Analyst

The test report shall not be reproduced except in full, without written approval of the laboratory. The report must not be used by the client to claim product certification, approval, or endorsement by NVLAP, NIST, or any agency of the federal government. The Company reserves the right to dispose of all samples after a period of thirty (30) days, according to all state and federal guidelines, unless otherwise specified.

‡ A "Version" indicated by -"x" after the Lab ID# with a value greater than 1 indicates a sample with amended data. The revision number is reflected by the value of "x".

Analyst: Jason Bosse

EMLab ID: 4575324, Page 4 of 4Eurofins Aerotech Built Environment Testing, LLC

Ogden Drivers License Division Mechanical Upgrades 07 08 2026
ACM Ogden DLD 07 08 26
Ogden Drivers License Division Mechanical Upgrades 07 08 2026
Project-4575324_Ogden DPS (002)
2026 Dahlk Hobbs HW ACM Lead Certs
scan_20260108062842
2025 Dahlk Hobbs HW ACM Lead Certs
2024 Dahlk HW Hobbs Asbestos Certs
2025 Dahlk Hobbs HW ACM Lead Certs
Hill West Lead Cert 2026

File details come from the government source that posted it. Updated .