09_2024 FVSU MultiBldg Auto Drawings.pdf

PDF 8 MB Posted

Attached to
FVSU Multi-Bldg Automation
Solicitation number
PE-53300-RFP-2025-000000027
Issued by
Oconee County, Georgia

About this file

This document outlines a state and local contract opportunity from Fort Valley State University (FVSU) located in the state of Georgia, Paulding County, to automate the HVAC systems in 6 buildings on the university campus. The project involves replacing existing HVAC controls and controllers with new digital direct control (DDC) systems. A mandatory pre-bid meeting is scheduled for 9/17/2024 at 10:00 AM, and interested contractors must submit their qualifications by the response due date. The contract term and any renewal options are not specified.

Regarding pricing and funding, the document does not provide details on the overall budget or cost estimates for the project. There is also no information on any set-aside requirements or incumbent contractors. The document indicates the project will be funded through state and local sources, but the specific amounts and sources are not disclosed.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

PROJECT CONSULTANTS

NBP ENGINEERS, INC.

MACON, GEORGIA316 CORPORATE PARKWAY

NBP

ENGINEERS

CONSULTANTS

478-745-1691 www.nbpengineers.com

M001

SHEET LISTING

ABBREVIATIONS, & LEGENDS - HVAC

Fort Valley, Georgia

Fort Valley State University -

MHL200

MHL201

MHL202

MHL203

MHL401

MHL402

MPA200

MPA201

MPA202

MPA401

MPA402

MPE401

MPE402

MPE403

MVS201

MVS401

MVS402

MVS403

VETERINARY SCIENCE - FIRST FLOOR PLAN - HVAC

VETERINARY SCIENCE - HEATING WATER FLOW DIAGRAM - HVAC

VETERINARY SCIENCE - CHILLED WATER FLOW DIAGRAM - HVAC

PATTON HALL - AHU FLOW DIAGRAM - HVAC

PATTON HALL - CHILLED WATER FLOW DIAGRAM - HVAC

PATTON HALL - BASEMENT FLOOR PLAN - HVAC

PATTON HALL - FIRST FLOOR PLAN - HVAC

HUNT LIBRARY - HEATING WATER FLOW DIAGRAM - HVAC

HUNT LIBRARY - CHILLED WATER FLOW DIAGRAM - HVAC

HUNT LIBRARY - THIRD FLOOR PLAN - HVAC

HUNT LIBRARY - FIRST FLOOR PLAN - HVAC

HUNT LIBRARY - SECOND FLOOR PLAN - HVAC

HUNT LIBRARY - BASEMENT FLOOR PLAN - HVAC

MHH200

MHH201

MHH202

MHH203

MHH204

HUNTINGTON HALL - FIRST FLOOR PLAN - HVAC

HUNTINGTON HALL - SECOND FLOOR PLAN - HVAC

HUNTINGTON HALL - THIRD FLOOR PLAN - HVAC

HUNTINGTON HALL - ATTIC FLOOR PLAN - HVAC

HUNTINGTON HALL - GOUND FLOOR PLAN - HVAC

PATTON HALL - SECOND & ROOF/ATTIC FLOOR PLAN - HVAC

MPE201 PEABODY TRADES BUILDING - FIRST & SECOND FLOOR PLANS - HVAC

PEABODY TRADES BUILDING - CHILLED WATER FLOW DIAGRAM - HVAC

PEABODY TRADES BUILDING - HEATING WATER FLOW DIAGRAM - HVAC

PEABODY TRADES BUILDING - AHU FLOW DIAGRAM - HVAC

MWR201 WARNER ROBINS FACILITY - PARTIAL FIRST FLOOR PLAN - HVAC

MWR202 WARNER ROBINS FACILITY - PARTIAL FIRST FLOOR PLAN - HVAC

MHL403 HUNT LIBRARY - AHU FLOW DIAGRAM - HVAC

MHH401

MWR401

MWR402

MWR403

WARNER ROBINS FACILITY - CHILLED WATER FLOW DIAGRAM - HVAC

WARNER ROBINS FACILITY - HEATING WATER FLOW DIAGRAM - HVAC

WARNER ROBINS FACILITY - AHU FLOW DIAGRAM - HVAC

SHEET LISTING

HUNTINGTON HALL - AH-CV SYSTEM FLOW DIAGRAM - HVACMHH402

MHH403 HUNTINGTON HALL - AHU FLOW DIAGRAM - HVAC

HUNTINGTON HALL - ERU UNITS FLOW DIAGRAM - HVAC

MVS404 VETERINARY SCIENCE - AHU FLOW DIAGRAM - HVAC

VETERINARY SCIENCE - AH-CV SYSTEM FLOW DIAGRAM - HVAC

MHH404

HUNTINGTON HALL - CHILLED WATER FLOW DIAGRAM - HVAC

FVSU Project No. FVSUBAS-92024

BID SET 08.13.24

Multi-Buildings Automation Systems Project

SEAL

SCALE:

FILE PATH:

SHEET NUMBER:

316 CORPORATE PARKWAY

NBP Engineers, Inc.

MACON, GEORGIA 31210

NBP

ENGINEERS

478-745-1691 www.nbpengineers.com

No. REVISIONS/SUBMISSIONS DATE

DRAWN:

CHECKED:

DESIGNED:

DATE:

PROJECT NUMBER:

P R

O J E

C T

T

IT

L E

SHEET TITLE:

CONSULTANTS

THIS DRAWING IS THE PROPERTY OF THE

ENGINEER AND MAY NOT BE REPRODUCED

OR USED IN WHOLE OR IN PART

WITHOUT HIS WRITTEN PERMISSION. IT IS

TO BE USED FOR THE PROJECT

SPECIFICALLY IDENTIFIED HEREIN AND TO

BE RETURNED UPON REQUEST.

P:\24012\24012m001.dgn

AS SHOWN

WSH

LTF

WSH

24012

08.13.24

P:\24012\24012m001.dgn

DATE PLOTTED

DGN FILE

13-AUG-2024

F o rt V a ll e y

G e o rg ia

COA Expiration: 6.30.2026

COA#PEF000774

NBP Engineers, Inc.

F V S

U P ro je c t

N o F

V S

U B

A S -9

B

ID

S E

T

M u lt i- B u il d in g s A u to m a ti o n S y s te m s P ro je c t

F o rt V a ll e y S ta te U n iv e rs it y

M001

A COMPRESSED AIR

AAV AUTOMATIC AIR VENT

AF AIR FOIL

-AFF ABOVE FINISHED FLOOR

AV ACID VENT

AVD AUTOMATIC VOLUME DAMPER

AW ACID WASTE

-AC ABOVE CEILING

AH- AIR HANDLING UNIT

BBD BOILER BLOW DOWN

BE BOTTOM ELEVATION

BOL BOTTOM OF LINE (UNINSULATED)

BOD BOTTOM OF DUCT

BP- BOOSTER PUMP

BTUH BRITISH THERMAL UNIT PER HOUR

-BF BELOW FLOOR

BFP BACK FLOW PREVENTOR

C CONDUIT

CC COOLING COIL

CHR CHILLED WATER RETURN

CHS CHILLED WATER SUPPLY

CR CONDENSER WATER RETURN

CS CONDENSER WATER SUPPLY

CW DOMESTIC COLD WATER

CAB CABINET FAN

CF CENTRIFICAL FAN

CFM CUBIC FEET PER MINUTE

CFP CHEMICAL FEED PUMP

CFT CHEMICAL FEED TANK

CH CABINET HEATER

CHR CHILLER

CL CENTER LINE

CO CLEANOUT

CP CHILLER PUMP

CPHB CHROME PLATED HOSE BIBB

CT COOLING TOWER

CU COPPER

CV- CONVECTOR

Cv VALVE COEFFICIENT

D DRAIN

DDC DIRECT DIGITAL CONTROL

DHW DOMESTIC HOT WATER

DN DOWN

DP DIFFERENTIAL PRESSURE

DS DOWN SPOUT

DSO DOWN SPOUT OVER FLOW

DX DIRECT EXCHANGE

EAD EXHAUST AIR DAMPER

EAT ENTERING AIR TEMPERATURE

EDB ENTERING DRY BULB

EWB ENTERING WET BULB

ESP END SUCTION PUMP

ESP EXTERNAL STATIC PRESSURE

ELL ELBOW

ET EXPANSION TANK

EQT EQUIPMENT TRAP SET

EWT ENTERING WATER TEMPERATURE

EX EXPANSION TANK LINE

EXT EXTERNAL

FOB FLAT ON BOTTOM

FOT FLAT ON TOP

F&BP FACE & BYPASS

FC FAN COIL UNIT

BPD BYPASS DAMPER

EAL EXHAUST AIR LOUVER

ECH ELECTRIC CABINET HEATER

ABBREVIATIONS

FD FLOOR DRAIN

FF FOULING FACTOR

FF- FLY FAN

FF FINISHED FLOOR

FF FINAL FILTER

FFM FIRE FLOW METER

FLEX FLEXIBLE

FM FIRE MAIN

FMS FLOW METER STATION

FOF FUEL OIL FLOW

FOR FUEL OIL RETURN

FOV FUEL OIL VENT

FOP FUEL OIL PUMP

FP FIRE PUMP

FP- FAN POWERED

FPM FEET PER MINUTE

FPS FEET PER SECOND

FRT FLOW RATE TRANSMITTER

FT FEET

G LOW PRESSURE GAS

GA GAUGE

GPM GALLONS PER MINUTE

GT GREASE TRAP

GTH GRAND TOTAL HEAT

H HEIGHT

HC HEATING COIL

HB HOSE BIBB

HBT HORIZONTAL BLOW THROUGH

HD HUB DRAIN

HDT HORIZONTAL DRAW THROUGH

HP HORSEPOWER/HIGH PRESSURE

HPA HIGH PRESSURE AIR

HPG HIGH PRESSURE GAS

HPS HIGH PRESSURE STEAM

HPWS HEAT PUMP WATER SUPPLY

HPWR HEAT PUMP WATER RETURN

HSC HORIZONTAL SPLIT CASE

HWG HOT WATER GENERATOR

HWR HEATING WATER RETURN

HWS HEATING WATER SUPPLY

ILC IN-LINE CENTRIFICAL

IT INTERVAL TIMER

IN INCHES

INV INVERT

JB JUNCTION BOX

L LENGTH

LR LONG RADIUS

LAT LEAVING AIR TEMPERATURE

LCP LOCAL CONTROL PANEL

LDB LEAVING DRY BULB

LN LIQUID NITROGEN

LWB LEAVING WET BULB

LWT LEAVING WATER TEMPERATURE

LPS LOW PRESSURE STEAM

MAV MANUAL AIR VENT

MVD MANUAL VOLUME DAMPER

MAX MAXIMUM

MBH ONE THOUSAND BTUH PER HOUR

MCC MOTOR CONTROL CENTER

MIN MINIMUM

MH MAN HOLE

MP SUMP (MUD) PUMP

MPS MEDIUM PRESSURE STEAM

MPR MEDIUM PRESSURE RETURN

MTS MEDIUM TEMPERATURE SUPPLY

MTR MEDIUM TEMPERATURE RETURN

MUA MAKE-UP AIR

MUW MAKE-UP WATER

MZ MULTIZONE

NC NORMALLY CLOSED

NIC NOT IN CONTRACT

NO NORMALLY OPEN

NTS NOT TO SCALE

OA OUTSIDE AIR

OAD OUTSIDE AIR DAMPER

ODT OUTDOOR TEMPERATURE

PC PUMP CONDENSATE

PD PRESSURE DROP

PRV PRESSURE REDUCING VALVE

PWF PROPELLER WALL FAN

R REFRIGERANT

RA RETURN AIR

RAD RETURN AIR DAMPER

RAS RELIEF AIR SUPPLY

RP RECIRCULATING PUMP

RHG REFRIGERANT HOT GAS

RL REFRIGERANT LIQUID

RS REFRIGERANT SUCTION

RD ROOF DRAIN

RV RELIEF VALVE

SR SHORT RADIUS

OAL OUTSIDE AIR LOUVER

SAN SANITARY SEWER

SC SILL COCK

SCD SMOKE DAMPER

SD STORM DRAIN

SD SMOKE DETECTOR

SF SQUARE FEET

SDO STORM DRAIN OVERFLOW

SHC SENSIBLE HEAT CAPACITY

SP STAND PIPE

SP SUMP PUMP

SPS STATIC PRESSURE SENSOR

STA STATION

TR TEMPERED WATER RETURN

UG UNDERGROUND

VAC VACUUM PIPING

VDT VERTICAL DRAW THROUGH

VTR VENT THROUGH ROOF

WB WET BULB

O2 OXYGEN

?F DEGREES FAHRENHEIT

?C DEGREES CENTIGRADE

WM WATER METER

WL WATER LINE

WH WATER HEATER

WG WATER GAUGE

W WIDTH

W WASTE

VT VERTICAL TURBINE

VFD VARIABLE FREQUENCY DRIVE

VB VACUUM BREAKER

VAV VARIABLE AIR VOLUME

V VENT

UC UNDERCUT (DOOR - 3/4")

V- VALVE

TOS TOP OF STRUCTURE

TB THRUST BLOCK

T TEMPERED WATER

STR STRAINER

SP STATIC PRESSURE

SP SPRINKLER PIPE

SG SPECIALTY GAS

EUH ELECTRIC UNIT HEATER

RECIRCULATING

DHR DOMESTIC HOT WATER

TRANSMITTER

DPT DIFFERENTIAL PRESSURE

PER MINUTE

SCIM STANDARD CUBIC INCHES

TEMPERATURE

SST SATURATED SUCTION

(UNINSULATED)

TE TOP ELEVATION

(TOWER) PUMP

TP CONDENSER WATER

FSD FIRE/SMOKE DAMPER

EA EXHAUST AIR

MA MIXED AIR

AE ADJUSTABLE AIR EXTRACTOR

RAO RETURN AIR OPENING

AD AREA DRAIN/ACCESS DOOR

SINGLE LINE DUCT LEGEND

DUCT (SUPPLY, RETURN & EXHAUST)

SUPPLY DUCT UP

SUPPLY DUCT DOWN

RETURN OR EXHAUST DUCT UP

RETURN OR EXHAUST DUCT DOWN

DUCT RISE

DUCT DOWN

VOLUME DAMPER (MANUAL UNLESS INDICATED A.V.D.)

TRANSITION

DUCT TAKE-OFF (SEE SPEC. PERTAINING TO DEFLECTROLS)

TRANSITION (FLAT ON TOP)

TRANSITION (FLAT ON BOTTOM)

TRANSITION (TOP OR BOTTOM ONLY)

SUPPLY CEILING DIFFUSER

RETURN OR EXHAUST CEILING GRILLE

SIDEWALL SUPPLY

SIDEWALL RETURN

FLEXIBLE CONNECTION (DUCT)

RELIEF AIR SUPPLY TO TOILET

DUCT SPLIT WITH SPLITTER DAMPER

FLEX. DUCT WITH SCREW ON COLLAR, TAKE-OFF

DUCT WITH DUCT LINER

SQUARE ELBOW WITH TURNING VANES

RADIUS ELBOW (SEE SPECS. PERTAINING TO TURNING VANES)

AUTOMATIC VOLUME DAMPER

DN

R

12\10 SPLIT

OR

OR

SCD

FOB

T OR B

RAS

AVD

FD/SCD

FD

SMOKE CONTROL DAMPER

COMBINATION FIRE/SMOKE CONTROL DAMPER

FIRE DAMPER (FD)

FIRE DAMPER

SPS

SD

COMBINATION STARTER

STARTER

PIPE SLEEVE

CONCENTRIC REDUCER

PIPE ANCHOR

HVAC LEGEND

BALL VALVE WITH

3/4" HOSE END

BALANCE VALVE

THREADED & FLANGED

GLOBE VALVE

CHECK VALVE

3-WAY MIXING VALVE

BALL VALVE

BUTTERFLY VALVE

SOLENOID VALVE

CONTROL VALVE

PLAN VIEW

2-WAY MOTORIZED VALVE

RELIEF VALVE

FLANGED UNION

BRANCH OUT TOP

STRAINER

BRANCH OUT BOTTOM

ELBOW DOWN

ELBOW UP

TEE OUT TOP

BLIND FLANGE

PIPE CAP

AUTOMATIC AIR VENTAAV

FLEX. PIPE CONN.

BACKFLOW PREVENTER

THERMOMETER

TEE OUT BOTTOM

MANUAL AIR VENT

PIPE TEST PLUG

HEATING WATER FLOW

COLD WATER DOMESTIC

NATURAL GAS

CONDENSER WATER FLOW

DRAIN

HEATING WATER RETURN

HOT WATER DOMESTIC

G

D

DUCT SIZE FIRST DIMENSION

IS SIDE SHOWN

24\12

DOOR GRILLE

REFERS TO DETAIL OR

PLAN ON SHEET M-1.THERMOSTAT

INTERVAL TIMER

T

I.T.

1\M-4

DUCT/PLENUM w/LINER

FIRE DAMPER

ELBOW WITH

TURNING VANES

FLEX. DUCT CONN.

TURNING VANES

ELBOW WITHOUT

ADJUSTABLE AIR

EXTRACTOR

INSULATED FLEX. DUCT

INSULATED FLEX. DUCT

c

ECCENTRIC REDUCER

HWS

HWR

SCHS

SCHR

CONDENSER WATER RETURN

CS

CR

STATIC PRESSURE SENSOR

SMOKE DETECTOR

POINT OF CONNECTION

DUCT SPLIT

THREADED & FLANGED

THREADED & FLANGED

UNION

GAUGE TAPPING

GAUGE WITH TAPPING

THREADED & FLANGED

THREADED & FLANGED

PIPE SOCKET WELL

FLOW INDICATOR BALANCER

M

T G THERMOSTAT w/GROUND

ANNULAR ELEMENT FLOW STATION

M

DAMPER - BLADE VIEW DAMPER - END VIEW

xx{K OR xx/xx}K ROUND OR FLAT OVAL DUCT (K)

DOUBLE WALL INSULATED

ROUND OR FLAT OVAL DUCTxx{ OR xx/xx}

CHILLED WATER FLOW

CHILLED WATER RETURN

CHS

CHR

WATER SUPPLY

SECONDARY CHILLED

WATER RETURN

SECONDARY CHILLED

CV

CVA

CONSTANT VOLUME

ADJUSTABLE

CONSTANT VOLUME

CFM

PRESSURE SENSOR

SCHEDULE - HVAC

LEGENDS, &

ABBREVIATIONS,

FILE PATH:

SHEET NUMBER:

316 CORPORATE PARKWAY

NBP Engineers, Inc.

MACON, GEORGIA 31210

NBP

ENGINEERS

478-745-1691 www.nbpengineers.com

No. REVISIONS/SUBMISSIONS DATE

DRAWN:

CHECKED:

DESIGNED:

DATE:

PROJECT NUMBER:

P R

O J E

C T

T

IT

L E

SHEET TITLE:

CONSULTANTS

THIS DRAWING IS THE PROPERTY OF THE

ENGINEER AND MAY NOT BE REPRODUCED

OR USED IN WHOLE OR IN PART

WITHOUT HIS WRITTEN PERMISSION. IT IS

TO BE USED FOR THE PROJECT

SPECIFICALLY IDENTIFIED HEREIN AND TO

BE RETURNED UPON REQUEST.

P:\24012\24012mhh200.dgn

AS SHOWN

WSH

LTF

WSH

24012

08.13.24

P:\24012\24012mhh200.dgn

DATE PLOTTED

DGN FILE

13-AUG-2024

F o rt V a ll e y

G e o rg ia

COA Expiration: 6.30.2026

COA#PEF000774

NBP Engineers, Inc.

F V S

U P ro je c t

N o F

V S

U B

A S -9

T

M u lt i- B u il d in g s A u to m a ti o n S y s te m s P ro je c t

F o rt V a ll e y S ta te U n iv e rs it y

1 2 2 2 2 2

ELEVATOR LOBBY

A

B

MECH. RM.

EXIT LOBBY

MECH. RM.

E007

DATA RM.

01 1

ELECTRICAL

STAIR

LOWER LEVEL

MECH. RM.

MACHINE RM.

ELEVATOR

SWITCH RM.

TRANSFER

STORAGE

MECH. RM.

MECH. RM

CORRIDOR

CORRIDOR

SCALE:

= 1'-0

8 0 4 8 16

HUNTINGTON HALL - GROUND FLOOR PLAN - HVAC

MHH200

N

EXISTING

EWH-1

EXISTING

AHU-2

EXISTING

BCU-3

EXISTING

F-ELV-1

EXISTING

F-FP-1

EXISTING

P-CHW-A

EXISTING

P-CHW-B

EXISTING

BCU-2

EXISTING

BCU-1 EXISTING

AHU-1

EXISTING

ERV/OA-1

TT

T

MOD

EXISTING

CONTROLS

HVAC

EXISTING

CONTROLS

HVAC

EXISTING

HVAC CONTROLS

EXISTING

FLOOR PLAN - HVAC

GROUND

HUNTINGTON HALL -

NOTES:(THIS SHEET ONLY)

REPLACE EXISTING CONTROL PANEL AND ASSOCIATED CONTROLLER.

GENERAL NOTES:(THIS SHEET ONLY)

A

B

VERIFY ITEMS TO BE DEMOLISHED.

ALL CONDITIONS FOR NEW WORK MAY NOT BE SHOWN. SURVEY EXISTING CONDITIONS TO

MATCH EXISTING IF DAMAGED DURING CONSTRUCTION.

FINISHED SPACES. REPAIR/REPLACE ANY CEILING TILES, CEILING GRIDS, OR FIXTURES TO

REMOVE EXISTING CEILING TILES WHERE SCOPE OF WORK IS PERFORMED ABOVE

REPLACE EXISTING WALL MOUNTED TEMPERATURE SENSOR WITH NEW TEMPERATURE SENSOR.

FILE PATH:

SHEET NUMBER:

316 CORPORATE PARKWAY

NBP Engineers, Inc.

MACON, GEORGIA 31210

NBP

ENGINEERS

478-745-1691 www.nbpengineers.com

No. REVISIONS/SUBMISSIONS DATE

DRAWN:

CHECKED:

DESIGNED:

DATE:

PROJECT NUMBER:

P R

O J E

C T

T

IT

L E

SHEET TITLE:

CONSULTANTS

THIS DRAWING IS THE PROPERTY OF THE

ENGINEER AND MAY NOT BE REPRODUCED

OR USED IN WHOLE OR IN PART

WITHOUT HIS WRITTEN PERMISSION. IT IS

TO BE USED FOR THE PROJECT

SPECIFICALLY IDENTIFIED HEREIN AND TO

BE RETURNED UPON REQUEST.

P:\24012\24012mhh201.dgn

AS SHOWN

WSH

LTF

WSH

24012

08.13.24

P:\24012\24012mhh201.dgn

DATE PLOTTED

DGN FILE

13-AUG-2024

F o rt V a ll e y

G e o rg ia

COA Expiration: 6.30.2026

COA#PEF000774

NBP Engineers, Inc.

F V S

U P ro je c t

N o F

V S

U B

A S -9

T

M u lt i- B u il d in g s A u to m a ti o n S y s te m s P ro je c t

F o rt V a ll e y S ta te U n iv e rs it y

1 2 2 2 2 2

A

B

WORK ROOM

CORRIDOR

CORRIDOR

1 13

STAIR

1 14

MEN TOILET

GALLERY

ART EXHIBIT

CLOSET

COORDINATOR'S OFFICE

PRE-AWARD

COORDINATOR'S OFFICE

POST-AWARD

TECHNOLOGY OFFICE

INFORMATION

OFFICE

TITLE THREE

1 1 1

DATA CL.

1 10

JAN.

1 12

WOMEN TOILET

RECEPTIONIST

ENTRY LOBBY/

PORCH

LIFT

PLATFORM

VERT.

SCALE:

= 1'-0

8 0 4 8 16

HUNTINGTON HALL - FIRST FLOOR PLAN - HVAC

N

MHH201

T T

EXISTING

FCU-2

EXISTING

FCU-1

T

H

EXISTING

EWH

TT

EXISTING

FCU-4

EXISTING

FCU-3

EXISTING

EWH

TT

EXISTING

FCU-6

EXISTING

FCU-5

EXISTING

AC-1

ERV/OA-1

SMOKE DAMPER

EXISTING

FLOOR PLAN - HVAC

FIRST

HUNTINGTON HALL -

NOTES:(THIS SHEET ONLY)

SHUTDOWN SWITCH

EXISTING HVAC

REUSE

AHU-2

2 2

1 1

1 1

MATCH EXISTING IF DAMAGED DURING CONSTRUCTION.

FINISHED SPACES. REPAIR/REPLACE ANY CEILING TILES, CEILING GRIDS, OR FIXTURES TO

REMOVE EXISTING CEILING TILES WHERE SCOPE OF WORK IS PERFORMED ABOVE

GENERAL NOTES:(THIS SHEET ONLY)

A

B

VERIFY ITEMS TO BE DEMOLISHED.

ALL CONDITIONS FOR NEW WORK MAY NOT BE SHOWN. SURVEY EXISTING CONDITIONS TO

MATCH EXISTING IF DAMAGED DURING CONSTRUCTION.

FINISHED SPACES. REPAIR/REPLACE ANY CEILING TILES, CEILING GRIDS, OR FIXTURES TO

REMOVE EXISTING CEILING TILES WHERE SCOPE OF WORK IS PERFORMED ABOVE

REPLACE EXISTING WALL MOUNTED TEMPERATURE SENSOR WITH NEW TEMPERATURE SENSOR.

HUMIDITY SENSOR

REPLACE EXISTING

FILE PATH:

SHEET NUMBER:

316 CORPORATE PARKWAY

NBP Engineers, Inc.

MACON, GEORGIA 31210

NBP

ENGINEERS

478-745-1691 www.nbpengineers.com

No. REVISIONS/SUBMISSIONS DATE

DRAWN:

CHECKED:

DESIGNED:

DATE:

PROJECT NUMBER:

P R

O J E

C T

T

IT

L E

SHEET TITLE:

CONSULTANTS

THIS DRAWING IS THE PROPERTY OF THE

ENGINEER AND MAY NOT BE REPRODUCED

OR USED IN WHOLE OR IN PART

WITHOUT HIS WRITTEN PERMISSION. IT IS

TO BE USED FOR THE PROJECT

SPECIFICALLY IDENTIFIED HEREIN AND TO

BE RETURNED UPON REQUEST.

P:\24012\24012mhh202.dgn

AS SHOWN

WSH

LTF

WSH

24012

08.13.24

P:\24012\24012mhh202.dgn

DATE PLOTTED

DGN FILE

13-AUG-2024

F o rt V a ll e y

G e o rg ia

COA Expiration: 6.30.2026

COA#PEF000774

NBP Engineers, Inc.

F V S

U P ro je c t

N o F

V S

U B

A S -9

T

M u lt i- B u il d in g s A u to m a ti o n S y s te m s P ro je c t

F o rt V a ll e y S ta te U n iv e rs it y

1 2 2 2 2 2

A

B

VESTIBULE

STAIR

MEN TOILET

CLOSET

COORDINATOR'S OFFICE

PRE-AWARD

TECHNOLOGY OFFICE

INFORMATION

WOMEN TOILET

PORCH

CLOS.

DATA

21 1

ROOM

BREAK

CORRIDOR 1

CORRIDOR 2

CORRIDOR 3

ASST. OFFICE

DEVELOPMENT

AREA

RECEPTION

ROOM

COPY/WORK

OFFICE

EXTERNAL AFFAIRS

VICE PRESIDENT OF

LOUNGE

EXTERNAL AFFAIRS

VICE PRESIDENT OF

CONFERENCE ROOM

EXTERNAL AFFAIRS

VICE PRESIDENT OF

ASSISTANT

ADMINISTRATION

FILES/COPIER

CLOSET

CUSTOD.

205A

CLOSET

SCALE:

= 1'-0

8 0 4 8 16

HUNTINGTON HALL - SECOND FLOOR PLAN - HVAC

N

MHH202

T

FCU-8

EXISTING

FCU-7

EXISTING

T T T

EXISTING

T

FCU-9

EXISTING

FCU-10

TT

EXISTING EXISTING

FCU-12 FCU-1 1

EXISTING

AC-2

T

EXISTING

FCU-13

T

TBCU-2

BCU-1

BCU-3

FLOOR PLAN - HVAC

SECOND

HUNTINGTON HALL -

NOTES:(THIS SHEET ONLY)

GENERAL NOTES:(THIS SHEET ONLY)

A

B

VERIFY ITEMS TO BE DEMOLISHED.

ALL CONDITIONS FOR NEW WORK MAY NOT BE SHOWN. SURVEY EXISTING CONDITIONS TO

MATCH EXISTING IF DAMAGED DURING CONSTRUCTION.

FINISHED SPACES. REPAIR/REPLACE ANY CEILING TILES, CEILING GRIDS, OR FIXTURES TO

REMOVE EXISTING CEILING TILES WHERE SCOPE OF WORK IS PERFORMED ABOVE

CHW CONTROL VALVE ACTUATOR WITH NEW VALVE ACTUATOR.

REPLACE EXISTIGN FAN COIL UNIT CONTROLLER WITH NEW CONTOLLER. REPLACE EXISTING

1 1 1 1 1

FILE PATH:

SHEET NUMBER:

316 CORPORATE PARKWAY

NBP Engineers, Inc.

MACON, GEORGIA 31210

NBP

ENGINEERS

478-745-1691 www.nbpengineers.com

No. REVISIONS/SUBMISSIONS DATE

DRAWN:

CHECKED:

DESIGNED:

DATE:

PROJECT NUMBER:

P R

O J E

C T

T

IT

L E

SHEET TITLE:

CONSULTANTS

THIS DRAWING IS THE PROPERTY OF THE

ENGINEER AND MAY NOT BE REPRODUCED

OR USED IN WHOLE OR IN PART

WITHOUT HIS WRITTEN PERMISSION. IT IS

TO BE USED FOR THE PROJECT

SPECIFICALLY IDENTIFIED HEREIN AND TO

BE RETURNED UPON REQUEST.

P:\24012\24012mhh203.dgn

AS SHOWN

WSH

LTF

WSH

24012

08.13.24

P:\24012\24012mhh203.dgn

DATE PLOTTED

DGN FILE

13-AUG-2024

F o rt V a ll e y

G e o rg ia

COA Expiration: 6.30.2026

COA#PEF000774

NBP Engineers, Inc.

F V S

U P ro je c t

N o F

V S

U B

A S -9

T

M u lt i- B u il d in g s A u to m a ti o n S y s te m s P ro je c t

F o rt V a ll e y S ta te U n iv e rs it y

1 2 2 2 2 2

A

B

MEN TOILET

CLOSET

WOMEN TOILET

31 1

CLOS.

DATA

205A

CLOSET

PRESIDENT'S OFFICE

PRESIDENT'S SUITE

CORRIDOR

OFFICE

ASSISTANT'S

ADMIN.

LIBRARY

PRESIDENT'S

STORAGE

TOILET

PRESIDENT'S

RECEPTIONIST

PRINTER

FILE ROOM w/

WORK STUDY

ASSISTANT TO THE PRESIDENT

CORRIDOR

CONFERENCE RM.

BREAK ROOM

VEST.

CORRIDOR

J.C.

EXIST. STAIR

SCALE:

= 1'-0

8 0 4 8 16

HUNTINGTON HALL - THIRD FLOOR PLAN - HVAC

N

MHH203

VAV-3-3

T

T

VAV-3-4

TVAV-3-6 T VAV-3-8

EXISTING AC-3

T

VAV-3-1

T

VAV-3-7

T

VAV-3-5

T

VAV-3-2

FLOOR PLAN - HVAC

THIRD

HUNTINGTON HALL -

NOTES:(THIS SHEET ONLY)

GENERAL NOTES:(THIS SHEET ONLY)

A

B

VERIFY ITEMS TO BE DEMOLISHED.

ALL CONDITIONS FOR NEW WORK MAY NOT BE SHOWN. SURVEY EXISTING CONDITIONS TO

MATCH EXISTING IF DAMAGED DURING CONSTRUCTION.

FINISHED SPACES. REPAIR/REPLACE ANY CEILING TILES, CEILING GRIDS, OR FIXTURES TO

REMOVE EXISTING CEILING TILES WHERE SCOPE OF WORK IS PERFORMED ABOVE

FILE PATH:

SHEET NUMBER:

316 CORPORATE PARKWAY

NBP Engineers, Inc.

MACON, GEORGIA 31210

NBP

ENGINEERS

478-745-1691 www.nbpengineers.com

No. REVISIONS/SUBMISSIONS DATE

DRAWN:

CHECKED:

DESIGNED:

DATE:

PROJECT NUMBER:

P R

O J E

C T

T

IT

L E

SHEET TITLE:

CONSULTANTS

THIS DRAWING IS THE PROPERTY OF THE

ENGINEER AND MAY NOT BE REPRODUCED

OR USED IN WHOLE OR IN PART

WITHOUT HIS WRITTEN PERMISSION. IT IS

TO BE USED FOR THE PROJECT

SPECIFICALLY IDENTIFIED HEREIN AND TO

BE RETURNED UPON REQUEST.

P:\24012\24012mhh204.dgn

AS SHOWN

WSH

LTF

WSH

24012

08.13.24

P:\24012\24012mhh204.dgn

DATE PLOTTED

DGN FILE

13-AUG-2024

F o rt V a ll e y

G e o rg ia

COA Expiration: 6.30.2026

COA#PEF000774

NBP Engineers, Inc.

F V S

U P ro je c t

N o F

V S

U B

A S -9

T

M u lt i- B u il d in g s A u to m a ti o n S y s te m s P ro je c t

F o rt V a ll e y S ta te U n iv e rs it y

1 2 2 2 2 2

A

B

SCALE:

= 1'-0

8 0 4 8 16

HUNTINGTON HALL - ATTIC FLOOR PLAN - HVAC

N

MHH204

VAV-3-7

EXISTING

VAV-3-2

EXISTING

VAV-3-3

EXISTING

VAV-3-4

EXISTING

VAV-3-6

EXISTING

VAV-3-8

EXISTING

VAV-3-5

EXISTING

VAV-3-1

EXISTING

HVAC CONTROLS

EXISTING

EXISTING

AHU-3

EXISTING

AHU-4

MBLC

FLOOR PLAN - HVAC

ATTIC

HUNTINGTON HALL -

NOTES:(THIS SHEET ONLY)

GENERAL NOTES:(THIS SHEET ONLY)

A

VALVE ACTUATOR WITH NEW VALVE ACTUATOR.

REPLACE EXISTING TERMINAL UNIT CONTROLLER WITH NEW CONTROLLER. REPLACE EXISTING HW CONTROL

REPLACE EXISTING CONTROL PANEL AND ASSOCIATED CONTROLLERS.

REPLACE EXISTING TERMINAL UNIT CONTROLLER WITH NEW CONTROLLER.

FILE PATH:

SHEET NUMBER:

316 CORPORATE PARKWAY

NBP Engineers, Inc.

MACON, GEORGIA 31210

NBP

ENGINEERS

478-745-1691 www.nbpengineers.com

No. REVISIONS/SUBMISSIONS DATE

DRAWN:

CHECKED:

DESIGNED:

DATE:

PROJECT NUMBER:

P R

O J E

C T

T

IT

L E

SHEET TITLE:

CONSULTANTS

THIS DRAWING IS THE PROPERTY OF THE

ENGINEER AND MAY NOT BE REPRODUCED

OR USED IN WHOLE OR IN PART

WITHOUT HIS WRITTEN PERMISSION. IT IS

TO BE USED FOR THE PROJECT

SPECIFICALLY IDENTIFIED HEREIN AND TO

BE RETURNED UPON REQUEST.

P:\24012\24012mhh401.dgn

AS SHOWN

WSH

LTF

WSH

24012

08.13.24

P:\24012\24012mhh401.dgn

DATE PLOTTED

DGN FILE

13-AUG-2024

F o rt V a ll e y

G e o rg ia

COA Expiration: 6.30.2026

COA#PEF000774

NBP Engineers, Inc.

F V S

U P ro je c t

N o F

V S

U B

A S -9

T

M u lt i- B u il d in g s A u to m a ti o n S y s te m s P ro je c t

F o rt V a ll e y S ta te U n iv e rs it y

EXISTING TO REMAIN

DEMOLITION

NEW WORK

POINT OF CONNECTION

LINE LEGEND

NOT TO SCALE

TT

TT

CP-1

CHR CHR

CHS

C

H S

C H

R

SUCTION DIFFUSER

1" TO DOMESTIC WATER

SET 80#

RELIEF VALVE

CHEMICAL FEED TANK

AAV

AIR PURGER

FULL SIZE

EXTERIOR

INTERIOR MECH. ROOM

CHR-1

1"

CP-1

VALVE

3/4" DRAIN

EQUIPMENT

TO AIR HANDLING

STATION

MAKE-UP WATER

ACP

DDC PANEL

INPUT/OUTPUT

SUMMARIES

OUTPUTS INPUTS SOFTWARE

DIGITAL ANALOG ANALOG ALARM DDCDIGITAL ENERGY MGMT. LOGS

S Y

S T

M

G R

A P

H

IC

D

IS

P L

A Y

S T

A R

T

S T

O P

E N

A B

L E

D

IS

A B

L E

O P

E N

C L

O S

E

S T

A R

T

S T

O P

A

K E

U P

S E

T P

O

IN

T

J

U S

T

D

C

N T

R O

L

D

IF

F E

R E

N T

IA

L

P

R E S

S U

R E

P R

E S

S U

R E

S

W

IT

C H

A U

X

IL

IA

Y

N T

A C

T

A L

A

N T

A C

T

T E

M P

E R

A T

U R

E

H

IG

H

L

W

L

IM

IT

R U

N

T A

L

IZ

A T

IO

N

P R

O P

O R

T

IO

N A

L

P R

O P

IN

T E

G R

A L

T

IM

E

S

C H

E D

U L

E

S

S

O P

T

IM

A R

T

S T

O P

D A

Y

N

IG

T B

A C

K

D E

M A

IT

C Y

C L

E

R E S

T

IM

IZ

A T

IO

N

E C

O N

O M

IZ

E R

N O

T E S

C U

R R

E

L A

Y

S P

E E

D

IN

D

IC

A T

IO

N

S P

E

N T

R O

L

P O

S

IT

IO

N

IN

D

IC

A T

IO

N

O P

E N

C L

O S

S

IT

IO

N

P A

D D

L E

S

W

IT

C H

O P

E R

A T

A T

U S

D

IF

F

P

R E S

S U

R E

P R

E S

S U

R E

S T

A T

U S

K W

H

T R

E

G

W A

T

F

O W

G A

L

F A

IL

U

D E (S

T E S

A

N D

1. FAILURE MODES:

2. WHERE FAILURE MODE IS INDICATED, THE INDICATED POSITION SHALL OCCUR ON INTERRUPTION OF ELECTRIC POWER TO THE DDC PANEL

L - LAST COMMAND

O - OPEN OR ON

C - CLOSE OR OFF

NOTES:

C

C

TAG

CHR-1

TT-1

TT-2

EM-1

POINT DESCRIPTION

CHILLER

ELECTRIC METER - MAIN

BUILDING UTILITY MONITORING

A1

DO DI

EXISTING PURGE VALVE

A1

FM-DW

FM-GAS GAS METER

DW METER

G

O W

C C

F

MHL401

EXISTING

EXISTING

EXISTING

EXISTING

EXISTING

NEW

NEW EXISTING

EXISTING

EXISTING

EQUIPMENT

TO AIR HANDLING

CHW SUPPLY (SYSTEM) (NEW)

CHW RETURN (SYSTEM) (NEW)

CP-2

CP-2

DO DI

HVAC

FLOW DIAGRAM -

CHILLED WATER

HUNTINGTON HALL -

HUNTINGTON HALL - CHILLED WATER FLOW DIAGRAM - HVAC

3"

3"

3"

3"

3"

3"

3"

CHILLER SYSTEM

HUNTINGTON HALL

CP-1, CP-2 CHILLER PUMPS

20 PSIG INITIAL FILL PRESSURE VOLUME

DIAPHRAM EXPANSION TANK.

FILE PATH:

SHEET NUMBER:

316 CORPORATE PARKWAY

NBP Engineers, Inc.

MACON, GEORGIA 31210

NBP

ENGINEERS

478-745-1691 www.nbpengineers.com

No. REVISIONS/SUBMISSIONS DATE

DRAWN:

CHECKED:

DESIGNED:

DATE:

PROJECT NUMBER:

P R

O J E

C T

T

IT

L E

SHEET TITLE:

CONSULTANTS

THIS DRAWING IS THE PROPERTY OF THE

ENGINEER AND MAY NOT BE REPRODUCED

OR USED IN WHOLE OR IN PART

WITHOUT HIS WRITTEN PERMISSION. IT IS

TO BE USED FOR THE PROJECT

SPECIFICALLY IDENTIFIED HEREIN AND TO

BE RETURNED UPON REQUEST.

P:\24012\24012mhh402.dgn

AS SHOWN

WSH

LTF

WSH

24012

08.13.24

P:\24012\24012mhh402.dgn

DATE PLOTTED

DGN FILE

13-AUG-2024

F o rt V a ll e y

G e o rg ia

COA Expiration: 6.30.2026

COA#PEF000774

NBP Engineers, Inc.

F V S

U P ro je c t

N o F

V S

U B

A S -9

T

M u lt i- B u il d in g s A u to m a ti o n S y s te m s P ro je c t

F o rt V a ll e y S ta te U n iv e rs it y

EXISTING TO REMAIN

DEMOLITION

NEW WORK

POINT OF CONNECTION

LINE LEGEND

MHH402

NOT TO SCALE

DDC PANELS

INPUT/OUTPUT

SUMMARIES

ACP

O

C

C

C

AH-CV SYSTEM

HUNTINGTON HALL

HUNTINGTON HALL - AH-CV SYSTEM FLOW DIAGRAM - HVAC

ELECTRIC HEATING COIL

NOTES:

1. FAILURE MODES:

2. WHERE FAILURE MODE IS INDICATED, THE INDICATED POSITION SHALL OCCUR ON INTERRUPTION OF

ELECTRIC POWER TO THE DDC PANEL.

L - LAST COMMAND

O - OPEN OR ON

C - CLOSE OR OFF

PERCENTAGE DESIGN FLOW-HEATING

PERCENTAGE DESIGN FLOW-COOLING

TAG

FAR

ZONE-SPACE TEMP.

CC-L.A.T.

L.L.-TEMP.

T-XX

RA 1

FMS 1

OA 1

TT 2

TT 3

TT 4

TT 5

LL 1

SPS 1

TT 1

SA-VFD

EDH-L.A.T.

TT OA

DP 1 BUILDING PRESSURE

HT OA

HT RA

TT 8 EDH-2 LAT

AH-1 & AH-2

EHC

S Y

S T

A P

P L

A Y

S T

A R

T

S T

O P

E N

A B

L E

D

IS

A B

L E

O P

E N

C L

O S

E

S T

A R

T

S T

K E

U P

S E

T P

O

J

U S

T

D

N T

R O

L

D

IF

F E

R E

N T

IA

L

P

R E S

S U

R E

P R

E S

S U

R E

S

W

IT

C H

A U

X

IL

IA

N T

A C

T

A L

A

N T

A C

T

T E

M P

E R

A T

U R

E

R E

L A

T

IV

M

ID

IT

Y

P R

E S

S U

R E

H

IG

H

L

IT

R

T A

L

IZ

A T

IO

N

P R

O P

O R

T

IO

N A

L

P R

O P

IN

T E

G R

A L

T

IM

E

S

C H

E D

U L

E

S

S

O P

T

IM

A R

T

S T

O P

D A

Y

N

IG

T B

A C

K

D E

M A

IT

C Y

C L

E

R E S

T

IM

IZ

A T

IO

N

E C

O N

O M

IZ

E R

N O

T E S

C U

R R

E

L A

Y

D R

IV

E

S

T A

T U

S

S P

E E

D

IN

D

IC

A T

IO

N

S P

E

N T

R O

L

E

IT

C H

C O

C A

L C

U L

A T

IN

T

P O

S

IT

IO

N

IN

D

IC

A T

IO

N

O P

E N

C L

O S

S

IT

IO

N

T R

E

G

S T

A T

U S

IR

O W

W A

T

O W

F A

IL

U

D E (S

T E S

A

N D

ANALOGDIGITAL DIGITAL ANALOG ALARM DDC ENERGY MGMT. LOGS

SOFTWAREINPUTSOUTPUTS

VLV

FAR

AI

TT

SPS

AI

R

SAF

VFD

VFD

FAR

FIL

AHU AHU

AIDIAO DO

EHC

AHU

CC

RA

TT

HT

RAD

AI AI

AIAO

O .A

TT

TT

TT

AIAI AIC

H S

C H

R

LL

DI

AI

EHC

TT

AI

DP

HT

EXTERIOR WALL

AO

AO

OA

AIAO

S.A. FAN

AH-1 & AH-2

HVAC

FLOW DIAGRAM -

AH-CV SYSTEM

HUNTINGTON HALL -

AIAO

NEW

NEW NEW

SA

SD

FROM ERU

NEW

RA

RA

NEW NEW

NEW

OA

OA

NEW

NEW

NEW

EXISTING VFD

CONNECT TO

NEW NEW NEW NEW

SAFAN-VFD

FA RELAY

RA TEMP.

MA TEMP.

SA-TEMP.

GLOBAL OA TEMP.

GLOBAL OA RH

RA-RH

SA-SPS

MIN. OA DAMPER

MIN. OA FMS

RA DAMPER

FILE PATH:

SHEET NUMBER:

316 CORPORATE PARKWAY

NBP Engineers, Inc.

MACON, GEORGIA 31210

NBP

ENGINEERS

478-745-1691 www.nbpengineers.com

No. REVISIONS/SUBMISSIONS DATE

DRAWN:

CHECKED:

DESIGNED:

DATE:

PROJECT NUMBER:

P R

O J E

C T

T

IT

L E

SHEET TITLE:

CONSULTANTS

THIS DRAWING IS THE PROPERTY OF THE

ENGINEER AND MAY NOT BE REPRODUCED

OR USED IN WHOLE OR IN PART

WITHOUT HIS WRITTEN PERMISSION. IT IS

TO BE USED FOR THE PROJECT

SPECIFICALLY IDENTIFIED HEREIN AND TO

BE RETURNED UPON REQUEST.

P:\24012\24012mhh403.dgn

AS SHOWN

WSH

LTF

WSH

24012

08.13.24

P:\24012\24012mhh403.dgn

DATE PLOTTED

DGN FILE

13-AUG-2024

F o rt V a ll e y

G e o rg ia

COA Expiration: 6.30.2026

COA#PEF000774

NBP Engineers, Inc.

F V S

U P ro je c t

N o F

V S

U B

A S -9

T

M u lt i- B u il d in g s A u to m a ti o n S y s te m s P ro je c t

F o rt V a ll e y S ta te U n iv e rs it y

EXISTING TO REMAIN

DEMOLITION

NEW WORK

POINT OF CONNECTION

LINE LEGEND

MHH403

NOT TO SCALE

HUNTINGTON HALL - AHU FLOW DIAGRAM - HVAC

HVAC

AHU FLOW DIAGRAM -

HUNTINGTON HALL -

S T

A P

P L

A Y

S T

A R

T

S T

O P

E N

A B

L E

D

IS

A B

L E

O P

E N

C L

O S

E

S T

A R

T

S T

K E

U P

S E

T P

O

J

U S

T

D

N T

R O

L

D

IF

F E

R E

N T

IA

L

P

R E S

S U

R E

P R

E S

S U

R E

S

W

IT

C H

A U

X

IL

IA

N T

A C

T

A L

A

N T

A C

T

T E

M P

E R

A T

U R

E

R E

L A

T

M

ID

IT

Y

P R

E S

S U

R E

H

IG

H

L

IT

R

T A

L

IZ

A T

IO

N

P R

O P

O R

T

IO

N A

L

P R

O P

IN

T E

G R

A L

T

IM

E

S

C H

E D

U L

E

S

S

O P

T

IM

A R

T

S T

O P

D A

Y

N

IG

T B

A C

K

D E

M A

IT

C Y

C L

E

R E S

T

IM

IZ

A T

IO

N

E C

O N

O M

IZ

E R

F A

IL

U

D E (S

T E S

A

N D

N O

T E S

OUTPUTS INPUTS SOFTWARE

DDC PANELS

INPUT/OUTPUT

SUMMARIES

DIGITAL ANALOG ANALOG ALARM DDCDIGITAL

C U

R R

E

L A

Y

D R

IV

E

S

T A

T U

S

S P

E E

D

IN

D

IC

A T

IO

N

S P

E

N T

R O

L

E

IT

C H

C O

PRIMARY AIR FLOW

O

NOTES:

1. FAILURE MODES:

2. WHERE FAILURE MODE IS INDICATED, THE INDICATED POSITION SHALL OCCUR ON INTERRUPTION OF

ELECTRIC POWER TO THE DDC PANEL.

L - LAST COMMAND

C A

L C

U L

A T

IN

T

C

O - OPEN OR ON

C - CLOSE OR OFF

PERCENTAGE DESIGN FLOW-HEATING

PERCENTAGE DESIGN FLOW-COOLING

TAG

FAR

TUC-XX

TUC-XX

TUC-XX

ZONE-SPACE TEMP.

SAT

CC-L.A.T.

L.L.-TEMP.

T-XX

P O

S

IT

IO

N

IN

D

IC

A T

IO

N

O P

E N

C L

O S

S

IT

IO

N

ACP

C

RA 1

FMS 1

OA 1

TT 2

TT 3

TT 4

TT 5

LL 1

SPS 1

L

T R

E

G

ENERGY MGMT. LOGS

S T

A T

U S

AIR TERMINAL UNITS (TU)

TT 1

AH-4

SA-VFD

ELECTRIC HEATING COIL-SCR C

PHC-L.A.T.

TT OA

ELECTRIC HEATER-SCR C

DP 1 BUILDING PRESSURE

HT OA

HT RA

O W

W A

T

O W

FM-1 CHW FLOW

TT

AO

AI

DP

EXTERIOR WALL

AO

HT

R

TT

LL

TT

RA

TT

T

TUC

ZONE

COND.

T

TUC

ZONE

COND.

TU-X

TU-XX

AHU AHU

AIAI DI

AI

AI

AO AI

AO AI

AI

AI

AO AI

RAD AH-1

SCR

SCR

C H S

C H

R

T-XX

T-XX

AO AI

OA

AI

HT

O A

RA

RA

EXISTING

SA FAN

SA

SD

EXISTING

EXISTING

OA

OA

SAF

VFD

VFD

FAR

AIDIAODO

CCFIL

NEW

TU-X

SAT

NEW

SPS

AI

NEW

AI

TU-X

SAT

NEW

NEW

FAR

TT

AI

NEW

EXISTING VFD

CONNECT TO

NEWNEW NEW

NEW ACTUATOR

NEW ACTUATOR

NEW NEW

NEW

NEW

NEW

AH-VAV SYSTEM

HUNTINGTON HALL

PHC

AO AI

VLV

AHU

CC

SCR

AO

TT

AI

NEW

FROM ERU NEW ACTUATOR

MIN. OA DAMPER

MIN. OA FMS

SA FAN-VFD

FA RELAY

RA DAMPER

RA TEMP.

MA TEMP.

SA-TEMP.

GLOBAL OA TEMP.

GLOBAL OA RH

RA-RH

SA-SPS

SA DAMPER ACTUATOR

SA TEMP. TO ZONE

FILE PATH:

SHEET NUMBER:

316 CORPORATE PARKWAY

NBP Engineers, Inc.

MACON, GEORGIA 31210

NBP

ENGINEERS

478-745-1691 www.nbpengineers.com

No. REVISIONS/SUBMISSIONS DATE

DRAWN:

CHECKED:

DESIGNED:

DATE:

PROJECT NUMBER:

P R

O J E

C T

T

IT

L E

SHEET TITLE:

CONSULTANTS

THIS DRAWING IS THE PROPERTY OF THE

ENGINEER AND MAY NOT BE REPRODUCED

OR USED IN WHOLE OR IN PART

WITHOUT HIS WRITTEN PERMISSION. IT IS

TO BE USED FOR THE PROJECT

SPECIFICALLY IDENTIFIED HEREIN AND TO

BE RETURNED UPON REQUEST.

P:\24012\24012mhh404.dgn

AS SHOWN

WSH

LTF

WSH

24012

08.13.24

P:\24012\24012mhh404.dgn

DATE PLOTTED

DGN FILE

13-AUG-2024

F o rt V a ll e y

G e o rg ia

COA Expiration: 6.30.2026

COA#PEF000774

NBP Engineers, Inc.

F V S

U P ro je c t

N o F

V S

U B

A S -9

T

M u lt i- B u il d in g s A u to m a ti o n S y s te m s P ro je c t

F o rt V a ll e y S ta te U n iv e rs it y

EXISTING TO REMAIN

DEMOLITION

NEW WORK

POINT OF CONNECTION

LINE LEGEND

NOT TO SCALE

S T

A P

P L

A Y

S T

A R

T

S T

O P

E N

A B

L E

D

IS

A B

L E

O P

E N

C L

O S

E

S T

A R

T

S T

K E

U P

S E

T P

O

J

U S

T

D

N T

R O

L

D

IF

F E

R E

N T

IA

L

P

R E S

S U

R E

P R

E S

S U

R E

S

W

IT

C H

A U

X

IL

IA

N T

A C

T

A L

A

N T

A C

T

T E

M P

E R

A T

U R

E

R E

L A

T

M

ID

IT

Y

P R

E S

S U

R E

S T

A T

U S

IN

T E

R L

O C

K

H

IG

H

L

IT

R

T A

L

IZ

A T

IO

N

P R

O P

O R

T

IO

N A

L

P R

O P

IN

T E

G R

A L

T

IM

E

S

C H

E D

U L

E

S

S

O P

T

IM

A R

T

S T

O P

D A

Y

N

IG

T B

A C

K

D E

M A

IT

C Y

C L

E

R E S

T

IM

IZ

A T

IO

N

E C

O N

O M

IZ

E R

F A

IL

U

D E (S

T E S

A

N D

N O

T E S

OUTPUTS INPUTS SOFTWARE

DDC PANELS

INPUT/OUTPUT

SUMMARIES

DIGITAL ANALOG ANALOG ALARM DDC ENERGY MGMT.DIGITAL

C U

R R

E

L A

Y

D R

IV

E

S

T A

T U

S

S P

E E

D

IN

D

IC

A T

IO

N

S P

E

N T

R O

L

E

IT

C H

C O

O W

C

NOTES:

1. FAILURE MODES:

2. WHERE FAILURE MODE IS INDICATED, THE INDICATED POSITION SHALL OCCUR ON INTERRUPTION OF

ELECTRIC POWER TO THE DDC PANEL.

L - LAST COMMAND

C A

L C

U L

A T

IN

T

O - OPEN OR ON

C - CLOSE OR OFF

TAG

FAR

TT 1

P O

S

IT

IO

N

IN

D

IC

A T

IO

N

O P

E N

C L

O S

S

IT

IO

N

CHR

CHS

T

R

FC FC

ACP

SAF

T ZONE-SPACE TEMP.

T R

E

G S

FC

T

SAF SUPPLY FAN C

HC

FAN COIL-TYPICAL

A1

FAN COIL - FC

VLV 1 CC CONTROL VALVE

C

MVD

A1

FILTER

TT

TT

TT

AH AH

S T

A P

P L

A Y

S T

A R

T

S T

O P

E N

A B

L E

D

IS

A B

L E

O P

E N

C L

O S

E

S T

A R

T

S T

K E

U P

S E

T P

O

J

U S

T

D

N T

R O

L

D

IF

F E

R E

N T

IA

L

P

R E S

S U

R E

P R

E S

S U

R E

S

W

IT

C H

A U

X

IL

IA

N T

A C

T

A L

A

N T

A C

T

T E

M P

E R

A T

U R

E

R E

L A

T

M

ID

IT

Y

P R

E S

S U

R E

S T

A T

U S

IN

T E

R L

O C

K

H

IG

H

L

IT

R

T A

L

IZ

A T

IO

N

P R

O P

O R

T

IO

N A

L

P R

O P

IN

T E

G R

A L

T

IM

E

S

C H

E D

U L

E

S

S

O P

T

IM

A R

T

S T

O P

D A

Y

N

IG

T B

A C

K

D E

M A

IT

C Y

C L

E

R E S

T

IM

IZ

A T

IO

N

E C

O N

O M

IZ

E R

F A

IL

U

D E (S

T E S

A

N D

N O

T E S

OUTPUTS INPUTS SOFTWARE

DDC PANELS

INPUT/OUTPUT

SUMMARIES

DIGITAL ANALOG ANALOG ALARM DDC ENERGY MGMT.DIGITAL

C U

R R

E

L A

Y

D R

IV

E

S

T A

T U

S

S P

E E

D

IN

D

IC

A T

IO

N

S P

E

N T

R O

L

E

IT

C H

C O

O W

C

C

O

NOTES:

1. FAILURE MODES:

2. WHERE FAILURE MODE IS INDICATED, THE INDICATED POSITION SHALL OCCUR ON INTERRUPTION OF

ELECTRIC POWER TO THE DDC PANEL.

L - LAST COMMAND

C A

L C

U L

A T

IN

T

O - OPEN OR ON

C - CLOSE OR OFF

TAG

FAR

HT 2

P O

S

IT

IO

N

IN

D

IC

A T

IO

N

O P

E N

C L

O S

S

IT

IO

N

ACP

FAR

TT

HT

TT

FAR

HT

TT

FILTER

TT

HT

T R

E

G S

C

C

OA 1

EA 1

SF

EF EXHAUST FAN

SUPPLY FAN

TT 1

TT 2

TT 3

TT 4

TT 5

TT 6

HT 1

VLV 1

ERU-1

HTX MODULE

CC

C H S

C H

R

AH-1 AND FAN COILS

TO BUILDING DISTRIBUTION

EHC

A1 A1

A1A1

EHC

SA

R FAR

EA

A1

OA

A1

A1

EA

HUNTINGTON HALL - FAN COIL UNITS FLOW DIAGRAM - HVAC

NOT TO SCALE

HUNTINGTON HALL - ERU UNITS FLOW DIAGRAM - HVAC

FLOW DIAGRAM - HVAC

FAN COIL & ERU UNITS

HUNTINGTON HALL -

SA FAN

EXISTING

EXISTING

OA

RA

MIXING PLENUM

EXISTING COMMON

SD

OA FROM ERU-1

SA

VLV

A0 A1

FAR

TUC

TTFAR

CONDITIONED ZONE

EXISTING

CCFIL

OA

OA

OA ISOLATION DAMPER (2-POS.)

GLOBAL OA TEMP

GLOBAL OA RH

TT OA

HT OA

OA CONDITIONS

OA

OA

OAL

EA

EAL

EA

EA

SA

FAN

EA

FAN

SA

SD SD

E A

S A

HUNTINGTON HALL

FAN COIL UNITS

EHC ELECTRIC HEAT COIL

AO

EHC

HUNTINGTON HALL

ENERGY RECOVERY UNIT

ERV/OA-1

TT 7

C.C. CONTROL VALVE

ELECTRIC HEAT COIL

AO

EHC

TT

VLV

A0 A1

NEW

NEW

NEW

NEW

NEW

NEW ACTUATOR

NEW

NEW

NEW

NEW

A1A1 A1 A1

NEW NEW

NEW ACTUATOR

NEW ACTUATOR

NEW

NEW

NEW

SA TEMP.

FA RELAY

NEW ACTUATOR

EA ISOLATION DAMPER (2-POS.)

HTX-EAT SUPPLY

HTX-LAT SUPPLY

CC-LAT

UNIT-LAT SUPPLY

HTX-LAT EXHAUST

EHC LAT

UNIT-EAT EXHAUST

FA RELAY

SA-RH

EA-RH

MHH404

FILE PATH:

SHEET NUMBER:

316 CORPORATE PARKWAY

NBP Engineers, Inc.

MACON, GEORGIA 31210

NBP

ENGINEERS

478-745-1691 www.nbpengineers.com

No. REVISIONS/SUBMISSIONS DATE

DRAWN:

CHECKED:

DESIGNED:

DATE:

PROJECT NUMBER:

P R

O J E

C T

T

IT

L E

SHEET TITLE:

CONSULTANTS

THIS DRAWING IS THE PROPERTY OF THE

ENGINEER AND MAY NOT BE REPRODUCED

OR USED IN WHOLE OR IN PART

WITHOUT HIS WRITTEN PERMISSION. IT IS

TO BE USED FOR THE PROJECT

SPECIFICALLY IDENTIFIED HEREIN AND TO

BE RETURNED UPON REQUEST.

P:\24012\24012mhl200.dgn

AS SHOWN

WSH

LTF

WSH

24012

08.13.24

P:\24012\24012mhl200.dgn

DATE PLOTTED

DGN FILE

13-AUG-2024

F o rt V a ll e y

G e o rg ia

COA Expiration: 6.30.2026

COA#PEF000774

NBP Engineers, Inc.

F V S

U P ro je c t

N o F

V S

U B

A S -9

T

M u lt i- B u il d in g s A u to m a ti o n S y s te m s P ro je c t

F o rt V a ll e y S ta te U n iv e rs it y

B

BCDEF

S T

A

IR

B

R O

O M

M A

C H

IN

E

E L

E V

A T

O R

B

C O

R R

ID

O R

B

J A

N

IT

O

'S

O R

ELEC.

A R

E A

W A

Y

SCALE:

= 1'-0

8 0 4 8 16

HUNT LIBRARY - BASEMENT FLOOR PLAN - HVAC

N

FLOOR PLAN - HVAC

BASEMENT

HUNT LIBRARY -

HP-1

CP-1

BOILER

VFD-1

ACP

VFD-2

T

HW

T

EF-1 1

UH-1

EF-10

T

AIR COMPRESSOR

EXISTING CONTROL

CONCRETE PAD

EXISTING

CHEMICAL WATER TREATMENT

EXISTING CONTROL PANEL

CONCRETE PAD

EXISTING

SUPPORT BEAMS B.E. 10'-8"

EXISTING GRATING

SF-1

RF-1

T

EF-1 1

EXISTING

EXISTING

EXISTING

EXISTING

EXISTING

EXISTING

EXISTING EXISTING

EXISTING

EXISTING

EXISTING

EXISTING

EXISTING

STARTERS

EXISTING

AIR COOLED CHILLER

EXISTING

BP

INTAKE LOUVER

EXISTING OA

NOTES:(THIS SHEET ONLY)

EXISTING OUTSIDE AIR DAMPER TO REMAIN. REPLACE ACTUATOR. MINIMUM OUTSIDE AIR 9,500 CFM.

EXISTING SMOKE ISOLATION DAMPER TO REMAIN. PROVIDE NEW ACTUATOR.

PROVIDE NEW WALL TEMPERATURE SENSOR.

REPLACE EXISTING HW CONTROL VALVE WITH NEW ACTUATOR.

MHL200

5 REPLACE EXISTING CONTROL PANEL AND EXISTING CONTROLLERS.

GENERAL NOTES:(THIS SHEET ONLY)

A

VERIFY ITEMS TO BE DEMOLISHED.

ALL CONDITIONS FOR NEW WORK MAY NOT BE SHOWN. SURVEY EXISTING CONDITIONS TO

FILE PATH:

SHEET NUMBER:

316 CORPORATE PARKWAY

NBP Engineers, Inc.

MACON, GEORGIA 31210

NBP

ENGINEERS

478-745-1691 www.nbpengineers.com

No. REVISIONS/SUBMISSIONS DATE

DRAWN:

CHECKED:

DESIGNED:

DATE:

PROJECT NUMBER:

P R

O J E

C T

T

IT

L E

SHEET TITLE:

CONSULTANTS

THIS DRAWING IS THE PROPERTY OF THE

ENGINEER AND MAY NOT BE REPRODUCED

OR USED IN WHOLE OR IN PART

WITHOUT HIS WRITTEN PERMISSION. IT IS

TO BE USED FOR THE PROJECT

SPECIFICALLY IDENTIFIED HEREIN AND TO

BE RETURNED UPON REQUEST.

P:\24012\24012mhl201.dgn

AS SHOWN

WSH

LTF

WSH

24012

08.13.24

P:\24012\24012mhl201.dgn

DATE PLOTTED

DGN FILE

13-AUG-2024

F o rt V a ll e y

G e o rg ia

COA Expiration: 6.30.2026

COA#PEF000774

NBP Engineers, Inc.

F V S

U P ro je c t

N o F

V S

U B

A S -9

T

M u lt i- B u il d in g s A u to m a ti o n S y s te m s P ro je c t

F o rt V a ll e y S ta te U n iv e rs it y

1 2 3 4 5 6 7

UP

DN

UP

F

E

D

C

B

A

JAN.

OFFICE OFFICE

OFFICE

SHAFT

MECH.

MEN

WOMEN

STOR.

STOR.

WORK ROOM

SHIPPING-RECEIVING

HALL

OFFICE

CIR-RES

RESERVE

CIRCULATION-

KITCHENET

SECRETARY

OFFICE

ACQUISITIONS

TECHNICAL SERVICES

OFFICES

ADMINISTRATION

CORR.

COMPUTER LAB.

LOUNGE

LIBRARIAN'S

STOR.

MICROFORM READERS

# 2

ELEV.

# 1

ELEV.

STOR.

STOR.

STOR.

STOR.

CORR.

STOR.

133134

# 2

STAIR

# 1

STAIR

LIBRARIAN

REFERENCE

LOAN OFFICE

INTLIB.

CLOSET

H.TOIL.

H.TOIL.

138A

VESTIBULE

STORAGE

MEN'S TOILET

WOMEN'S TOILET

AH-1

TU1-4

TU1-6 TU1-5

TU1-2

TU1-1

TU1-8

TU1-7

TU1-9

TU1-10

TU1-12

TU1-13

TU1-15

TU1-14

TU1-16

TU1-18

TU1-17

TU1-3

T

T T

T

TT

T

T

T

T

T

T

TT

T

TU1-52

T TU1-54

T

T T

T

T

TT

CABINET HEATER

EXISTING

EXISTING FIN TUBE RADIANT HEATERS

CABINET HEATER

EXISTING

HUNT LIBRARY - FIRST FLOOR PLAN - HVAC

HVAC

FIRST FLOOR PLAN -

HUNT LIBRARY -

SCALE:

= 1'-0

8 0 4 8 16

EXISTING FIN TUBE

EXISTING FIN TUBE

CABINET HEATER

EXISTING

TU1-1 1

EF-7

EXISTING

EF-7

EXISTING

EF-8

EXISTING

EF-6

EXISTING

MOTORIZED

DAMPER

BALANCE

EXISTING

EXISTING

EXISTING

EXISTING

EXISTING

EXISTING

EXISTING

EXISTING

EXISTING

EXISTING

EXISTING

EXISTING

EXISTING

EXISTING

EXISTING

EXISTING

EXISTING

EXISTING

EXISTING

EXISTING

EXISTING EXISTING

TU1-56

EXISTING

N

EXISTING FIN TUBE RADIANT HEATERS

PANEL "HE"

PANEL "E"

PANEL "F"

NOTES:(THIS SHEET ONLY)

VALVE ACTUATOR WITH NEW VALVE ACTUATOR.

REPLACE EXISTING TERMINAL UNIT CONTROLLER WITH NEW CONTROLLER. REPLACE EXISTING HW CONTROL

3 REPLACE EXISTING HW CONTROL VALVE ACTUATOR WITH NEW ACTUATOR.

T

T

2 2

1 1

GENERAL NOTES:(THIS SHEET ONLY)

A

B

VERIFY ITEMS TO BE DEMOLISHED.

ALL CONDITIONS FOR NEW WORK MAY NOT BE SHOWN. SURVEY EXISTING CONDITIONS TO

MATCH EXISTING IF DAMAGED DURING CONSTRUCTION.

FINISHED SPACES. REPAIR/REPLACE ANY CEILING TILES, CEILING GRIDS, OR FIXTURES TO

REMOVE EXISTING CEILING TILES WHERE SCOPE OF WORK IS PERFORMED ABOVE

MHL201

FILE PATH:

SHEET NUMBER:

316 CORPORATE PARKWAY

NBP Engineers, Inc.

MACON, GEORGIA 31210

NBP

ENGINEERS

478-745-1691 www.nbpengineers.com

No. REVISIONS/SUBMISSIONS DATE

DRAWN:

CHECKED:

DESIGNED:

DATE:

PROJECT NUMBER:

P R

O J E

C T

T

IT

L E

SHEET TITLE:

CONSULTANTS

THIS DRAWING IS THE PROPERTY OF THE

ENGINEER AND MAY NOT BE REPRODUCED

OR USED IN WHOLE OR IN PART

WITHOUT HIS WRITTEN PERMISSION. IT IS

TO BE USED FOR THE PROJECT

SPECIFICALLY IDENTIFIED HEREIN AND TO

BE RETURNED UPON REQUEST.

P:\24012\24012mhl202.dgn

AS SHOWN

WSH

LTF

WSH

24012

08.13.24

P:\24012\24012mhl202.dgn

DATE PLOTTED

DGN FILE

13-AUG-2024

F o rt V a ll e y

G e o rg ia

COA Expiration: 6.30.2026

COA#PEF000774

NBP Engineers, Inc.

F V S

U P ro je c t

N o F

V S

U B

A S -9

T

M u lt i- B u il d in g s A u to m a ti o n S y s te m s P ro je c t

F o rt V a ll e y S ta te U n iv e rs it y

1 2 3 4 5 6 7

F

E

D

C

B

A

DN

UP

DN

JAN.

SHAFT

MECH.

VAULT

READING ROOM

FACULTY STUDIES

COPY

STOR.

F.S.

F.S.

F.S.

F.S.

F.S.

F.S.

F.S.

MEN,S TOILET

WOMEN,S TOILET

G.S.

G.S.

G.S.

G.S.

G.S.

G.S.

G.S.

G.S.

G.S.

G.S.

G.S.

G.S.

G.S.

STOR.

TRAINING

CONF.

CLASSROOM

# 2

ELEV.

# 2

STAIR # 1

STAIR

# 1

ELEV.

HALL

FOYER

STORAGE

BOOK

ROOM

WORK

OFFICE

201A

201B

COLLECTION

HERITAGE

201C

COLLECTION

HERITAGE

SCALE:

= 1'-0

8 0 4 8 16

HUNT LIBRARY - SECOND FLOOR PLAN - HVAC

HVAC

FLOOR PLAN -

SECOND

HUNT LIBRARY -

TU1-23

TU1-22

TU1-21

TU1-19

TU1-29

TU1-31

TU1-33

TU1-32

TU1-35

TU1-34TU1-37

TU1-38

TU1-39TU1-40

TU1-41

TU1-42

TU1-43

TU1-36

TU1-24

TU1-25

TU1-28

TU1-27

TU1-26

TU1-44

T

TU1-53

T

T

T

T

T

T

T

T

T

T

TTU1-55

T

T

T

ON ROOF

EXISTING EF-2

EXISTING

EXISTING

EXISTING

EXISTING

EXISTING

EXISTING

EXISTING

EXISTING

EXISTING

EXISTING

EXISTING

EXISTING

EXISTING

EXISTINGEXISTING

EXISTING EXISTING

EXISTING

EXISTING

EXISTING

EXISTING EXISTING EXISTING EXISTING

EXISTING

TU1-30

EXISTING

TU1-20

EXISTING

EXISTING FIN TUBE

EXISTING FIN TUBE

PANEL "C"

PANEL "D"

N

NOTES:(THIS SHEET ONLY)

VALVE ACTUATOR WITH NEW VALVE ACTUATOR.

REPLACE EXISTING TERMINAL UNIT CONTROLLER WITH NEW CONTROLLER. REPLACE EXISTING HW CONTROL

22222

T1

GENERAL NOTES:(THIS SHEET ONLY)

A

B

VERIFY ITEMS TO BE DEMOLISHED.

ALL CONDITIONS FOR NEW WORK MAY NOT BE SHOWN. SURVEY EXISTING CONDITIONS TO

MATCH EXISTING IF DAMAGED DURING CONSTRUCTION.

FINISHED SPACES. REPAIR/REPLACE ANY CEILING TILES, CEILING GRIDS, OR FIXTURES TO

REMOVE EXISTING CEILING TILES WHERE SCOPE OF WORK IS PERFORMED ABOVE

MHL202

FILE PATH:

SHEET NUMBER:

316 CORPORATE PARKWAY

NBP Engineers, Inc.

MACON, GEORGIA 31210

NBP

ENGINEERS

478-745-1691 www.nbpengineers.com

No. REVISIONS/SUBMISSIONS DATE

DRAWN:

CHECKED:

DESIGNED:

DATE:

PROJECT NUMBER:

P R

O J E

C T

T

IT

L E

SHEET TITLE:

CONSULTANTS

THIS DRAWING IS THE PROPERTY OF THE

ENGINEER AND MAY NOT BE REPRODUCED

OR USED IN WHOLE OR IN PART

WITHOUT HIS WRITTEN PERMISSION. IT IS

TO BE USED FOR THE PROJECT

SPECIFICALLY IDENTIFIED HEREIN AND TO

BE RETURNED UPON REQUEST.

P:\24012\24012mhl203.dgn

AS SHOWN

WSH

LTF

WSH

24012

08.13.24

P:\24012\24012mhl203.dgn

DATE PLOTTED

DGN FILE

13-AUG-2024

F o rt V a ll e y

G e o rg ia

COA Expiration: 6.30.2026

COA#PEF000774

NBP Engineers, Inc.

F V S

U P ro je c t

N o F

V S

U B

A S -9

T

M u lt i- B u il d in g s A u to m a ti o n S y s te m s P ro je c t

F o rt V a ll e y S ta te U n iv e rs it y

1 2 3 4 5 6 7 8

DN

DN

4.5

F

E

D

C

B

A

JAN.

STOR.

STUDY LOUNGE

COPY

MAIN READING ROOM

SEMINAR

SEMINAR

G.S.

MEN,S TOILET

WOMEN,S TOILET

G.S.

G.S.

G.S.

G.S.

G.S.

G.S.

G.S.

G.S.

G.S.

G.S.

GROUP STUDIES

HALL

ALCOVE

# 2

STAIR

# 2

ELEV.

# 1

STAIR

# 1

ELEV.

TYPING

SCALE:

= 1'-0

8 0 4 8 16

HUNT LIBRARY - THIRD FLOOR PLAN - HVAC

TU1-45

TU1-46

TU1-50

TU1-57

TU1-49

TU1-48

T

T

T

T

T

T

T

T T T

T

T T T

T

T

EF-9

MAIN READING ROOM

GROUP STUDIES

TU1-47

EF-4 ON ROOF

EXISTING FAN

EF-3 ON ROOF

EXISTING FAN

EF-2 ON ROOF

EXISTING FAN

EF-1 ON ROOF

EXISTING FAN

EXISTING FIN TUBE

EXISTING FIN TUBE

EXISTING

EXISTING

EXISTING

EXISTING

EXISTING

EXISTING

EXISTING

EXISTING

PANEL "HB"

PANEL "B"

PANEL "A"

PANEL "HA"

N

HVAC

THIRD FLOOR PLAN -

HUNT LIBRARY -

MHL203

NOTES:(THIS SHEET ONLY)

VALVE ACTUATOR WITH NEW VALVE ACTUATOR.

REPLACE EXISTING TERMINAL UNIT CONTROLLER WITH NEW CONTROLLER. REPLACE EXISTING HW CONTROL

T

TT

T

GENERAL NOTES:(THIS SHEET ONLY)

A

B

VERIFY ITEMS TO BE DEMOLISHED.

ALL CONDITIONS FOR NEW WORK MAY NOT BE SHOWN. SURVEY EXISTING CONDITIONS TO

MATCH EXISTING IF DAMAGED DURING CONSTRUCTION.

FINISHED SPACES. REPAIR/REPLACE ANY CEILING TILES, CEILING GRIDS, OR FIXTURES TO

REMOVE EXISTING CEILING TILES WHERE SCOPE OF WORK IS PERFORMED ABOVE

FILE PATH:

SHEET NUMBER:

316 CORPORATE PARKWAY

NBP Engineers, Inc.

MACON, GEORGIA 31210

NBP

ENGINEERS

478-745-1691 www.nbpengineers.com

No. REVISIONS/SUBMISSIONS DATE

DRAWN:

CHECKED:

DESIGNED:

DATE:

PROJECT NUMBER:

P R

O J E

C T

T

IT

L E

SHEET TITLE:

CONSULTANTS

THIS DRAWING IS THE PROPERTY OF THE

ENGINEER AND MAY NOT BE REPRODUCED

OR USED IN WHOLE OR IN PART

WITHOUT HIS WRITTEN PERMISSION. IT IS

TO BE USED FOR THE PROJECT

SPECIFICALLY IDENTIFIED HEREIN AND TO

BE RETURNED UPON REQUEST.

P:\24012\24012mhl401.dgn

AS SHOWN

WSH

LTF

WSH

24012

08.13.24

P:\24012\24012mhl401.dgn

DATE PLOTTED

DGN FILE

13-AUG-2024

F o rt V a ll e y

G e o rg ia

COA Expiration: 6.30.2026

COA#PEF000774

NBP Engineers, Inc.

F V S

U P ro je c t

N o F

V S

U B

A S -9

T

M u lt i- B u il d in g s A u to m a ti o n S y s te m s P ro je c t

F o rt V a ll e y S ta te U n iv e rs it y

EXISTING TO REMAIN

DEMOLITION

NEW WORK

POINT OF CONNECTION

LINE LEGEND

NOT TO SCALE

TT

TT

CP-1

CHR CHR

CHS

C

H S

C H

R

SUCTION DIFFUSER

1" TO DOMESTIC WATER

SET 80#

RELIEF VALVE

CHEMICAL FEED TANK

AAV

AIR PURGER

FULL SIZE

EXTERIOR

INTERIOR MECH. ROOM

CHR-1

1"

CP-1

6"

6"

6"

6"

VALVE

3/4" DRAIN

6"

EQUIPMENT

TO AIR HANDLING

STATION

MAKE-UP WATER

ACP

DDC PANEL

INPUT/OUTPUT

SUMMARIES

OUTPUTS INPUTS SOFTWARE

DIGITAL ANALOG ANALOG ALARM DDCDIGITAL ENERGY MGMT. LOGS

S Y

S T

A P

P L

A Y

S T

A R

T

S T

O P

E N

A B

L E

D

IS

A B

L E

O P

E N

C L

O S

E

S T

A R

T

S T

K E

U P

S E

T P

O

J

U S

T

D

N T

R O

L

D

IF

F E

R E

N T

IA

L

P

R E S

S U

R E

P R

E S

S U

R E

S

W

IT

C H

A U

X

IL

IA

N T

A C

T

A L

A

N T

A C

T

T E

M P

E R

A T

U R

E

H

IG

H

L

IT

R

T A

L

IZ

A T

IO

N

P R

O P

O R

T

IO

N A

L

P R

O P

IN

T E

G R

A L

T

IM

E

S

C H

E D

U L

E

S

S

O P

T

IM

A R

T

S T

O P

D A

Y

N

IG

T B

A C

K

D E

M A

IT

C Y

C L

E

R E S

T

IM

IZ

A T

IO

N

E C

O N

O M

IZ

E R

N O

T E S

C U

R R

E

L A

Y

S P

E E

D

IN

D

IC

A T

IO

N

S P

E

N T

R O

L

P O

S

IT

IO

N

IN

D

IC

A T

IO

N

O P

E N

C L

O S

S

IT

IO

N

P A

D D

L E

S

W

IT

C H

O P

E R

A T

A T

U S

D

IF

F

P

R E S

S U

R E

P R

E S

S U

R E

S T

A T

U S

K W

H

T R

E

G

W A

T

O W

G A

L

F A

IL

U

D E (S

T E S

A

N D

1. FAILURE MODES:

2. WHERE FAILURE MODE IS INDICATED, THE INDICATED POSITION SHALL OCCUR ON INTERRUPTION OF ELECTRIC POWER TO THE DDC PANEL

L - LAST COMMAND

O - OPEN OR ON

C - CLOSE OR OFF

NOTES:

C

C

TAG

CHR-1

TT-1

TT-2

EM-1

POINT DESCRIPTION

CHILLER

ELECTRIC METER - MAIN

BUILDING UTILITY MONITORING

A1

DO DI

PURGE VALVE

A1

FM-DW

FM-GAS GAS METER

DW METER

G

O W

C C

F

HVAC

FLOW DIAGRAM -

CHILLED WATER

HUNT LIBRARY -

HUNT LIBRARY - CHILLED WATER FLOW DIAGRAM - HVAC

MHL401

20 PSIG INITIAL FILL PRESSUREVOLUME.

DIAPHRAM EXPANSION TANK.

EXISTING

EXISTING

EXISTING

EXISTING

EXISTING

NEW

NEW

EXISTING

EXISTING

EXISTING

EQUIPMENT

TO AIR HANDLING

CP-1 CHILLER PUMP

CHW SUPPLY (SYSTEM) (NEW)

CHW RETURN (SYSTEM) (NEW)

CHILLER SYSTEM

HUNT LIBRARY

FILE PATH:

SHEET NUMBER:

316 CORPORATE PARKWAY

NBP Engineers, Inc.

MACON, GEORGIA 31210

NBP

ENGINEERS

478-745-1691 www.nbpengineers.com

No. REVISIONS/SUBMISSIONS DATE

DRAWN:

CHECKED:

DESIGNED:

DATE:

PROJECT NUMBER:

P R

O J E

C T

T

IT

L E

SHEET TITLE:

CONSULTANTS

THIS DRAWING IS THE PROPERTY OF THE

ENGINEER AND MAY NOT BE REPRODUCED

OR USED IN WHOLE OR IN PART

WITHOUT HIS WRITTEN PERMISSION. IT IS

TO BE USED FOR THE PROJECT

SPECIFICALLY IDENTIFIED HEREIN AND TO

BE RETURNED UPON REQUEST.

P:\24012\24012mhl402.dgn

AS SHOWN

WSH

LTF

WSH

24012

08.13.24

P:\24012\24012mhl402.dgn

DATE PLOTTED

DGN FILE

13-AUG-2024

F o rt V a ll e y

G e o rg ia

COA Expiration: 6.30.2026

COA#PEF000774

NBP Engineers, Inc.

F V S

U P ro je c t

N o F

V S

U B

A S -9

T

M u lt i- B u il d in g s A u to m a ti o n S y s te m s P ro je c t

F o rt V a ll e y S ta te U n iv e rs it y

EXISTING TO REMAIN

DEMOLITION

NEW WORK

POINT OF CONNECTION

LINE LEGEND

NOT TO SCALE

HVAC

FLOW DIAGRAM -

HEATING WATER

HUNT LIBRARY -

HUNT LIBRARY - HEATING WATER FLOW DIAGRAM - HVAC

O

S Y

S T

A P

P L

A Y

S T

A R

T

S T

O P

E N

A B

L E

D

IS

A B

L E

O P

E N

C L

O S

E

S T

A R

T

S T

K E

U P

S E

T P

O

J

U S

T

D

N T

R O

L

D

IF

F E

R E

N T

IA

L

P

R E S

S U

R E

P R

E S

S U

R E

S

W

IT

C H

A U

X

IL

IA

N T

A C

T

A L

A

N T

A C

T

T E

M P

E R

A T

U R

E

H

IG

H

L

IT

R

T A

L

IZ

A T

IO

N

P R

O P

O R

T

IO

N A

L

P R

O P

IN

T E

G R

A L

T

IM

E

S

C H

E D

U L

E

S

S

O P

T

IM

A R

T

S T

O P

D A

Y

N

IG

T B

A C

K

D E

M A

IT

C Y

C L

E

R E S

T

IM

IZ

A T

IO

N

E C

O N

O M

IZ

E R

C U

R R

E

L A

Y

S P

E E

D

IN

D

IC

A T

IO

N

S P

E

N T

R O

L

P O

S

IT

IO

N

IN

D

IC

A T

IO

N

O P

E R

A T

A T

U S

D

IF

F

P

R E S

S U

R E

K W

P R

E S

S U

R E

W A

T

O W

S T

E

O W

S T

A T

U S

D R

IV

E

S

T A

T U

S

T R

E

G

F A

IL

U

D E (S

T E S

A

N D

N O

T E S

SOFTWAREINPUTSOUTPUTS

ANALOGDIGITAL DIGITAL ANALOG ALARM DDC ENERGY MGMT. LOGS

POINT DESCRIPTION

BOILERBLR-1

TAG

BHP-1

TT-1

TT-2

TT-3

TT-4

HWR - (SYSTEM)

HWS - (SYSTEM)

LOW WATER LEVEL

BLR-1 PUMP

HP-1 HEATING SYSTEM PUMP-VFD CONTROL

HWR - BLR LOOP

HWS - BLR-1 LOOP

DP-1 DIFFERENTIAL PRESSURE SENSOR-BUILDING LOOP

1. FAILURE MODES:

2. WHERE FAILURE MODE IS INDICATED, THE INDICATED POSITION SHALL OCCUR ON INTERRUPTION OF

ELECTRIC POWER TO THE DDC PANEL.

L - LAST COMMAND

O - OPEN OR ON

C - CLOSE OR OFF

DDC PANEL

ACP

INPUT/OUTPUT

SUMMARIES

NOTES:

MAKE-UP WATER STATION

1"C.W.

FILL

3" HWS

A.A.V.

TT

BOILER

BLR-1

TO HEATING

EQUIPMENT COILS

DRAIN WITH HOSE

END CONNECTION

(TYP.)

CHEMICAL FEED TANK

HP-1

TT

A0

BP-1

TT

GAS

ET

BALANCING FLOW METER

1"

AI

D0 D1

HP-1

3"HWS

TT

3" HWR

FLOW METER

BALANCING

D0 D1

TO HEATING

EQUIPMENT COILS

D0 A0 D1

BHP-1

1"

3"

3"

AI

AI

AIR SEPARATOR

TANGENTIAL

PURGE VALVE

EXPANSION TANK, 15 PSI FILL PRESSURE

MHL402

NEW

NEW

NEW

NEW

EXISTING

EXISTING

EXISTING

EXISTING

EXISTING

EXISTING

EXISTING

EXISTING

EXISTING

1"

BOILER PLANT SYSTEM

FILE PATH:

SHEET NUMBER:

316 CORPORATE PARKWAY

NBP Engineers, Inc.

MACON, GEORGIA 31210

NBP

ENGINEERS

478-745-1691 www.nbpengineers.com

No. REVISIONS/SUBMISSIONS DATE

DRAWN:

CHECKED:

DESIGNED:

DATE:

PROJECT NUMBER:

P R

O J E

C T

T

IT

L E

SHEET TITLE:

CONSULTANTS

THIS DRAWING IS THE PROPERTY OF THE

ENGINEER AND MAY NOT BE REPRODUCED

OR USED IN WHOLE OR IN PART

WITHOUT HIS WRITTEN PERMISSION. IT IS

TO BE USED FOR THE PROJECT

SPECIFICALLY IDENTIFIED HEREIN AND TO

BE RETURNED UPON REQUEST.

P:\24012\24012mhl403.dgn

AS SHOWN

WSH

LTF

WSH

24012

08.13.24

P:\24012\24012mhl403.dgn

DATE PLOTTED

DGN FILE

13-AUG-2024

F o rt V a ll e y

G e o rg ia

COA Expiration: 6.30.2026

COA#PEF000774

NBP Engineers, Inc.

F V S

U P ro je c t

N o F

V S

U B

A S -9

T

M u lt i- B u il d in g s A u to m a ti o n S y s te m s P ro je c t

F o rt V a ll e y S ta te U n iv e rs it y

NOT TO SCALE

DDC PANELS

INPUT/OUTPUT

SUMMARIES

ACP

S Y

S T

A P

P L

A Y

S T

A R

T

S T

O P

E N

A B

L E

D

IS

A B

L E

O P

E N

C L

O S

E

S T

A R

T

S T

K E

U P

S E

T P

O

J

U S

T

D

N T

R O

L

D

IF

F E

R E

N T

IA

L

P

R E S

S U

R E

P R

E S

S U

R E

S

W

IT

C H

A U

X

IL

IA

N T

A C

T

A L

A

N T

A C

T

T E

M P

E R

A T

U R

E

R E

L A

T

M

ID

IT

Y

P R

E S

S U

R E

H

IG

H

L

IT

R

T A

L

IZ

A T

IO

N

P R

O P

O R

T

IO

N A

L

P R

O P

IN

T E

G R

A L

T

IM

E

S

C H

E D

U L

E

S

S

O P

T

IM

A R

T

S T

O P

D A

Y

N

IG

T B

A C

K

D E

M A

IT

C Y

C L

E

R E S

T

IM

IZ

A T

IO

N

E C

O N

O M

IZ

E R

F A

IL

U

D E (S

T E S

A

N D

N O

T E S

DIGITAL ANALOG ANALOG ALARM DDC ENERGY MGMT.DIGITAL

C U

R R

E

L A

Y

D R

IV

E

S

T A

T U

S

S P

E E

D

IN

D

IC

A T

IO

N

S P

E

N T

R O

L

E

IT

C H

C O

O W

C A

L C

U L

A T

IN

T

P O

S

IT

IO

N

IN

D

IC

A T

IO

N

O P

E N

C L

O S

S

IT

IO

N

S T

A T

U S

T R

E

G

LOGS

PHC CONTROL VALVE

R.A. TEMP.

PHC-L.A.T.

R.A.-RH

PRIMARY AIR FLOW

AIR TERMINAL UNITS (TU/FP)

S.A. DAMPER ACTUATOR

HC VALVE

PERCENTAGE DESIGN FLOW-HEATING

PERCENTAGE DESIGN FLOW-COOLING

TAG

OA 1

AFMS 1

FAR

TT 1

TT 2

TT 3

TT 4

SPS H

SPS 1

TUC-XX

TUC-XX

TUC-XX

ZONE-SPACE TEMP.

S.A. TEMP. TO ZONESAT

LL

HT

M.A. TEMP.

CC-L.A.T.

S.A.-SPS

S.A.-TEMP.

L.L.-TEMP.

T-XX

CC CONTROL VALVE

TT 5

VLV 1

VLV 2

HIGH LIMIT SPS

BUILDING PRESSUREDP 1

AHU-1

VFD 1, 2

O

C

L

C

L

C

NOTES:

1. FAILURE MODES:

2. WHERE FAILURE MODE IS INDICATED, THE INDICATED POSITION SHALL OCCUR ON INTERRUPTION OF

ELECTRIC POWER TO THE DDC PANEL.

L - LAST COMMAND

O - OPEN OR ON

C - CLOSE OR OFF

SOFTWAREINPUTSOUTPUTS

TT

FAR

DP

SAF

VFD

FAR

VLV

TT

LL

TT

TT

VLV

1 2

SPS

AI

FIL PHC

TUC

T-X

TUC

T-X

SAT

TU-X

SAT

TU-X

SPS

H

AID0 A0 D1

AH-1 AH-1 AH-1

CC

R

AHU

EXTERIOR

WALL

H W

R

H W

S

COND.

ZONE

H W

R

H W

S

COND.

ZONE

CHS

CHRHWR

HWS

MCP

TU-X

TU-X

T

T

AI

NEW

AI

NEW

AI AO

NEW

AI

NEW

NEW

AI

AI

NEW

AI AO

DI

NEW

DI

NEW

SD

SASA FAN

AI

NEW

DI

NEW

AI

NEW

AI

NEW

AI AO

NEW ACTUATOR

AI AO

NEW ACTUATOR

EXISTING VFD

CONNECT TO

VFD

TT

AI

HT

AI

AI AO

OA

NEW ACTUATOR

AI

NEW

AFMS

LOUVER

OA INTAKE

EXISTING

EXISTING

EXISTING

EXISTING

MHL403

HVAC

AHU FLOW DIAGRAM -

HUNT LIBRARY -

SA FAN

VFD

FAR

AID0 A0 D1

R

EXISTING VFD

CONNECT TO

VFD

RAF

HUNT LIBRARY - AHU FLOW DIAGRAM - HVAC

AHU VAV SYSTEM

HUNT LIBRARY

RA/SA FAN-VFD

MIN. OA AFMS

MIN. OA DAMPER

F.A. RELAY

S T

A P

P L

A Y

S T

A R

T

S T

O P

E N

A B

L E

D

IS

A B

L E

O P

E N

C L

O S

E

S T

A R

T

S T

K E

U P

S E

T P

O

J

U S

T

D

N T

R O

L

D

IF

F E

R E

N T

IA

L

P

R E S

S U

R E

P R

E S

S U

R E

S

W

IT

C H

A U

X

IL

IA

N T

A C

T

A L

A

N T

A C

T

T E

M P

E R

A T

U R

E

R E

L A

T

M

ID

IT

Y

P R

E S

S U

R E

S T

A T

U S

IN

T E

R L

O C

K

H

IG

H

L

IT

R

T A

L

IZ

A T

IO

N

P R

O P

O R

T

IO

N A

L

P R

O P

IN

T E

G R

A L

T

IM

E

S

C H

E D

U L

E

S

S

O P

T

IM

A R

T

S T

O P

D A

Y

N

IG

T B

A C

K

D E

M A

IT

C Y

C L

E

R E S

T

IM

IZ

A T

IO

N

E C

O N

O M

IZ

E R

F A

IL

U

D E (S

T E S

A

N D

N O

T E S

OUTPUTS INPUTS SOFTWARE

DDC PANELS

INPUT/OUTPUT

SUMMARIES

DIGITAL ANALOG ANALOG ALARM DDC ENERGY MGMT.DIGITAL

C U

R R

E

L A

Y

D R

IV

E

S

T A

T U

S

S P

E E

D

IN

D

IC

A T

IO

N

S P

E

N T

R O

L

E

IT

C H

C O

O W

S.A. TEMP.

C

NOTES:

1. FAILURE MODES:

2. WHERE FAILURE MODE IS INDICATED, THE INDICATED POSITION SHALL OCCUR ON INTERRUPTION OF

ELECTRIC POWER TO THE DDC PANEL.

L - LAST COMMAND

C A

L C

U L

A T

IN

T

O - OPEN OR ON

C - CLOSE OR OFF

TAG

FAR

TT 1

F.A. RELAY

P O

S

IT

IO

N

IN

D

IC

A T

IO

N

O P

E N

C L

O S

S

IT

IO

N

CHR

CHS

T

R

FC FC

ACP

T ZONE-SPACE TEMP.

T R

E

G S

HWR

HWS

VLV

FC

T

1 2

SAF SUPPLY FAN C

HC

FAN COIL-TYPICAL

A1

FAN COIL - FC

VLV 1 HC CONTROL VALVE

VLV 2 CC CONTROL VALVE

C

MVD

A1

NOT TO SCALE

HUNT LIBRARY - FAN COIL UNITS FLOW DIAGRAM - HVAC

OA

OA FROM ERU-1

RA SA

SD

FAR

SAF

ZONE

CONDITIONED

TUC

TTFAR

CCFIL

VLV

A0 A1 A0 A1

NEW ACTUATOR

NEW ACTUATOR

COMMON MIXING PLENUM

EXISTING

EXISTING

SA FAN

EXISTING

FILE PATH:

SHEET NUMBER:

316 CORPORATE PARKWAY

NBP Engineers, Inc.

MACON, GEORGIA 31210

NBP

ENGINEERS

478-745-1691 www.nbpengineers.com

No. REVISIONS/SUBMISSIONS DATE

DRAWN:

CHECKED:

DESIGNED:

DATE:

PROJECT NUMBER:

P R

O J E

C T

T

IT

L E

SHEET TITLE:

CONSULTANTS

THIS DRAWING IS THE PROPERTY OF THE

ENGINEER AND MAY NOT BE REPRODUCED

OR USED IN WHOLE OR IN PART

WITHOUT HIS WRITTEN PERMISSION. IT IS

TO BE USED FOR THE PROJECT

SPECIFICALLY IDENTIFIED HEREIN AND TO

BE RETURNED UPON REQUEST.

P:\24012\24012mpat200.dgn

AS SHOWN

WSH

LTF

WSH

24012

08.13.24

P:\24012\24012mpat200.dgn

DATE PLOTTED

DGN FILE

13-AUG-2024

F o rt V a ll e y

G e o rg ia

COA Expiration: 6.30.2026

COA#PEF000774

NBP Engineers, Inc.

F V S

U P ro je c t

N o F

V S

U B

A S -9

T

M u lt i- B u il d in g s A u to m a ti o n S y s te m s P ro je c t

F o rt V a ll e y S ta te U n iv e rs it y

RAMP

STORAGE No. 1

STORAGE No. 2

PASSAGE

SERVICE

ROOM

MECHANICAL

BOILER ROOM

No. 3

STORAGE

ROOM

MACHINE

ELEV

SCALE:

= 1'-0

8 0 4 8 16

N

FLOOR PLAN - HVAC

BASEMENT

PATTON HALL -

PATTON HALL - BASEMENT FLOOR PLAN - HVAC

AHU-1

ACP-1

CP-1

UH-1

EXISTING

PUMP TO REMAIN

EXISTING SUMP

FILTER

HC

AX

CC

FAN

EXPANSION TANK

EXISTING CHW

HOUSEKEEPING PAD

EXISTING

EXPANSION TANK

EXISTING HEATING

T.E. 6'-0"

STACKED AT WALL;

EXISTING HP-1 & HP-2

STARTER-HP-1

EXISTING

STARTER-HP-1

EXISTING

CHEMICAL FEED TANK

EXISTING HW

EXISTING

HOUSEKEEPING PAD

EXISTING

STARTER-CP-1

EXISTING

CHEMICAL FEED TANK

EXISTING CHW

EXISTING

HOUSEKEEPING PAD

EXISTING

CH-1

EXISTING

TRANSFORMER

EXISTING

JUNCTION BOX

EXISTING ELEC.

EXISTING

STARTER-AHU-1

MPA200

NOTES:(THIS SHEET ONLY)

GENERAL NOTES:(THIS SHEET ONLY)

A

VERIFY ITEMS TO BE DEMOLISHED.

ALL CONDITIONS FOR NEW WORK MAY NOT BE SHOWN. SURVEY EXISTING CONDITIONS TO

REMOVE EXISTING CONTROLLERS AND PROVIDE NEW CONTROLLERS.

FILE PATH:

SHEET NUMBER:

316 CORPORATE PARKWAY

NBP Engineers, Inc.

MACON, GEORGIA 31210

NBP

ENGINEERS

478-745-1691 www.nbpengineers.com

No. REVISIONS/SUBMISSIONS DATE

DRAWN:

CHECKED:

DESIGNED:

DATE:

PROJECT NUMBER:

P R

O J E

C T

T

IT

L E

SHEET TITLE:

CONSULTANTS

THIS DRAWING IS THE PROPERTY OF THE

ENGINEER AND MAY NOT BE REPRODUCED

OR USED IN WHOLE OR IN PART

WITHOUT HIS WRITTEN PERMISSION. IT IS

TO BE USED FOR THE PROJECT

SPECIFICALLY IDENTIFIED HEREIN AND TO

BE RETURNED UPON REQUEST.

P:\24012\24012mpat201.dgn

AS SHOWN

WSH

LTF

WSH

24012

08.13.24

P:\24012\24012mpat201.dgn

DATE PLOTTED

DGN FILE

13-AUG-2024

F o rt V a ll e y

G e o rg ia

COA Expiration: 6.30.2026

COA#PEF000774

NBP Engineers, Inc.

F V S

U P ro je c t

N o F

V S

U B

A S -9

T

M u lt i- B u il d in g s A u to m a ti o n S y s te m s P ro je c t

F o rt V a ll e y S ta te U n iv e rs it y

CORRIDOR

LOBBY

RECEPTION

DEPARTMENT

ROOM

BAND & ORCHESTRA

RM. No.5

PRACTICE

RM. No.4

PRACTICE

INSTRUMENT STORAGE

PASSAGE No. 4

P A

S S

A o

PASSAGE No. 6

PORCH

No. 4

PASSAGE

NO.1

TOILETS

WOMEN'S

NO.1

TOILETS

MEN'S

LOBBY

TOILETS

TEACHERS

WOMEN'S

TOILETS

TEACHERS

MEN'S

CLOS.

JAN.

WORK RM

EXIST. RAMP

STORAGE

UNIFORM

No. 2

STAIR

ELEV.

VESTIBULE

ROOM

CHOIR

CLASSROOM

STUDIO

DEPT HEAD/VOICE

INSTRUMENT

STORAGE

CONFERENCE

ROOM

VESTIBULE

KITCHENETTE

1 1 1

PATTON HALL - FIRST FLOOR PLAN - HVAC

HVAC

FIRST FLOOR PLAN -

PATTON HALL -

SCALE:

= 1'-0

8 0 4 8 16

N

WH

ENTRANCE

FIBER OPTIC

T

T

T

T

T

TU1-10

EF1-1

TU1-1

TU1-1 1

T

T

T

T

TU1-3

TU1-2

TU1-5

TU1-4

TU1-9TU1-8TU1-7

TU1-6

B1 B

EXISTING

EXISTING

EXISTING

EXISTING

EXISTING

EXISTING EXISTING EXISTING

EXISTING

EXISTING

EXISTING

EXISTING

T

MPA201

NOTES:(THIS SHEET ONLY)

VALVE ACTUATOR WITH NEW VALVE ACTUATOR.

REPLACE EXISTING…

This is the start of the file's text. The full file is on GovTribe.

File details come from the government source that posted it. Updated .