09_2024 FVSU MultiBldg Auto Drawings.pdf
PDF 8 MB Posted
- Attached to
- FVSU Multi-Bldg Automation
- Solicitation number
- PE-53300-RFP-2025-000000027
- Issued by
- Oconee County, Georgia
About this file
This document outlines a state and local contract opportunity from Fort Valley State University (FVSU) located in the state of Georgia, Paulding County, to automate the HVAC systems in 6 buildings on the university campus. The project involves replacing existing HVAC controls and controllers with new digital direct control (DDC) systems. A mandatory pre-bid meeting is scheduled for 9/17/2024 at 10:00 AM, and interested contractors must submit their qualifications by the response due date. The contract term and any renewal options are not specified.
Regarding pricing and funding, the document does not provide details on the overall budget or cost estimates for the project. There is also no information on any set-aside requirements or incumbent contractors. The document indicates the project will be funded through state and local sources, but the specific amounts and sources are not disclosed.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
PROJECT CONSULTANTS
NBP ENGINEERS, INC.
MACON, GEORGIA316 CORPORATE PARKWAY
NBP
ENGINEERS
CONSULTANTS
478-745-1691 www.nbpengineers.com
M001
SHEET LISTING
ABBREVIATIONS, & LEGENDS - HVAC
Fort Valley, Georgia
Fort Valley State University -
MHL200
MHL201
MHL202
MHL203
MHL401
MHL402
MPA200
MPA201
MPA202
MPA401
MPA402
MPE401
MPE402
MPE403
MVS201
MVS401
MVS402
MVS403
VETERINARY SCIENCE - FIRST FLOOR PLAN - HVAC
VETERINARY SCIENCE - HEATING WATER FLOW DIAGRAM - HVAC
VETERINARY SCIENCE - CHILLED WATER FLOW DIAGRAM - HVAC
PATTON HALL - AHU FLOW DIAGRAM - HVAC
PATTON HALL - CHILLED WATER FLOW DIAGRAM - HVAC
PATTON HALL - BASEMENT FLOOR PLAN - HVAC
PATTON HALL - FIRST FLOOR PLAN - HVAC
HUNT LIBRARY - HEATING WATER FLOW DIAGRAM - HVAC
HUNT LIBRARY - CHILLED WATER FLOW DIAGRAM - HVAC
HUNT LIBRARY - THIRD FLOOR PLAN - HVAC
HUNT LIBRARY - FIRST FLOOR PLAN - HVAC
HUNT LIBRARY - SECOND FLOOR PLAN - HVAC
HUNT LIBRARY - BASEMENT FLOOR PLAN - HVAC
MHH200
MHH201
MHH202
MHH203
MHH204
HUNTINGTON HALL - FIRST FLOOR PLAN - HVAC
HUNTINGTON HALL - SECOND FLOOR PLAN - HVAC
HUNTINGTON HALL - THIRD FLOOR PLAN - HVAC
HUNTINGTON HALL - ATTIC FLOOR PLAN - HVAC
HUNTINGTON HALL - GOUND FLOOR PLAN - HVAC
PATTON HALL - SECOND & ROOF/ATTIC FLOOR PLAN - HVAC
MPE201 PEABODY TRADES BUILDING - FIRST & SECOND FLOOR PLANS - HVAC
PEABODY TRADES BUILDING - CHILLED WATER FLOW DIAGRAM - HVAC
PEABODY TRADES BUILDING - HEATING WATER FLOW DIAGRAM - HVAC
PEABODY TRADES BUILDING - AHU FLOW DIAGRAM - HVAC
MWR201 WARNER ROBINS FACILITY - PARTIAL FIRST FLOOR PLAN - HVAC
MWR202 WARNER ROBINS FACILITY - PARTIAL FIRST FLOOR PLAN - HVAC
MHL403 HUNT LIBRARY - AHU FLOW DIAGRAM - HVAC
MHH401
MWR401
MWR402
MWR403
WARNER ROBINS FACILITY - CHILLED WATER FLOW DIAGRAM - HVAC
WARNER ROBINS FACILITY - HEATING WATER FLOW DIAGRAM - HVAC
WARNER ROBINS FACILITY - AHU FLOW DIAGRAM - HVAC
SHEET LISTING
HUNTINGTON HALL - AH-CV SYSTEM FLOW DIAGRAM - HVACMHH402
MHH403 HUNTINGTON HALL - AHU FLOW DIAGRAM - HVAC
HUNTINGTON HALL - ERU UNITS FLOW DIAGRAM - HVAC
MVS404 VETERINARY SCIENCE - AHU FLOW DIAGRAM - HVAC
VETERINARY SCIENCE - AH-CV SYSTEM FLOW DIAGRAM - HVAC
MHH404
HUNTINGTON HALL - CHILLED WATER FLOW DIAGRAM - HVAC
FVSU Project No. FVSUBAS-92024
BID SET 08.13.24
Multi-Buildings Automation Systems Project
SEAL
SCALE:
FILE PATH:
SHEET NUMBER:
316 CORPORATE PARKWAY
NBP Engineers, Inc.
MACON, GEORGIA 31210
NBP
ENGINEERS
478-745-1691 www.nbpengineers.com
No. REVISIONS/SUBMISSIONS DATE
DRAWN:
CHECKED:
DESIGNED:
DATE:
PROJECT NUMBER:
P R
O J E
C T
T
IT
L E
SHEET TITLE:
CONSULTANTS
THIS DRAWING IS THE PROPERTY OF THE
ENGINEER AND MAY NOT BE REPRODUCED
OR USED IN WHOLE OR IN PART
WITHOUT HIS WRITTEN PERMISSION. IT IS
TO BE USED FOR THE PROJECT
SPECIFICALLY IDENTIFIED HEREIN AND TO
BE RETURNED UPON REQUEST.
P:\24012\24012m001.dgn
AS SHOWN
WSH
LTF
WSH
24012
08.13.24
P:\24012\24012m001.dgn
DATE PLOTTED
DGN FILE
13-AUG-2024
F o rt V a ll e y
G e o rg ia
COA Expiration: 6.30.2026
COA#PEF000774
NBP Engineers, Inc.
F V S
U P ro je c t
N o F
V S
U B
A S -9
B
ID
S E
T
M u lt i- B u il d in g s A u to m a ti o n S y s te m s P ro je c t
F o rt V a ll e y S ta te U n iv e rs it y
M001
A COMPRESSED AIR
AAV AUTOMATIC AIR VENT
AF AIR FOIL
-AFF ABOVE FINISHED FLOOR
AV ACID VENT
AVD AUTOMATIC VOLUME DAMPER
AW ACID WASTE
-AC ABOVE CEILING
AH- AIR HANDLING UNIT
BBD BOILER BLOW DOWN
BE BOTTOM ELEVATION
BOL BOTTOM OF LINE (UNINSULATED)
BOD BOTTOM OF DUCT
BP- BOOSTER PUMP
BTUH BRITISH THERMAL UNIT PER HOUR
-BF BELOW FLOOR
BFP BACK FLOW PREVENTOR
C CONDUIT
CC COOLING COIL
CHR CHILLED WATER RETURN
CHS CHILLED WATER SUPPLY
CR CONDENSER WATER RETURN
CS CONDENSER WATER SUPPLY
CW DOMESTIC COLD WATER
CAB CABINET FAN
CF CENTRIFICAL FAN
CFM CUBIC FEET PER MINUTE
CFP CHEMICAL FEED PUMP
CFT CHEMICAL FEED TANK
CH CABINET HEATER
CHR CHILLER
CL CENTER LINE
CO CLEANOUT
CP CHILLER PUMP
CPHB CHROME PLATED HOSE BIBB
CT COOLING TOWER
CU COPPER
CV- CONVECTOR
Cv VALVE COEFFICIENT
D DRAIN
DDC DIRECT DIGITAL CONTROL
DHW DOMESTIC HOT WATER
DN DOWN
DP DIFFERENTIAL PRESSURE
DS DOWN SPOUT
DSO DOWN SPOUT OVER FLOW
DX DIRECT EXCHANGE
EAD EXHAUST AIR DAMPER
EAT ENTERING AIR TEMPERATURE
EDB ENTERING DRY BULB
EWB ENTERING WET BULB
ESP END SUCTION PUMP
ESP EXTERNAL STATIC PRESSURE
ELL ELBOW
ET EXPANSION TANK
EQT EQUIPMENT TRAP SET
EWT ENTERING WATER TEMPERATURE
EX EXPANSION TANK LINE
EXT EXTERNAL
FOB FLAT ON BOTTOM
FOT FLAT ON TOP
F&BP FACE & BYPASS
FC FAN COIL UNIT
BPD BYPASS DAMPER
EAL EXHAUST AIR LOUVER
ECH ELECTRIC CABINET HEATER
ABBREVIATIONS
FD FLOOR DRAIN
FF FOULING FACTOR
FF- FLY FAN
FF FINISHED FLOOR
FF FINAL FILTER
FFM FIRE FLOW METER
FLEX FLEXIBLE
FM FIRE MAIN
FMS FLOW METER STATION
FOF FUEL OIL FLOW
FOR FUEL OIL RETURN
FOV FUEL OIL VENT
FOP FUEL OIL PUMP
FP FIRE PUMP
FP- FAN POWERED
FPM FEET PER MINUTE
FPS FEET PER SECOND
FRT FLOW RATE TRANSMITTER
FT FEET
G LOW PRESSURE GAS
GA GAUGE
GPM GALLONS PER MINUTE
GT GREASE TRAP
GTH GRAND TOTAL HEAT
H HEIGHT
HC HEATING COIL
HB HOSE BIBB
HBT HORIZONTAL BLOW THROUGH
HD HUB DRAIN
HDT HORIZONTAL DRAW THROUGH
HP HORSEPOWER/HIGH PRESSURE
HPA HIGH PRESSURE AIR
HPG HIGH PRESSURE GAS
HPS HIGH PRESSURE STEAM
HPWS HEAT PUMP WATER SUPPLY
HPWR HEAT PUMP WATER RETURN
HSC HORIZONTAL SPLIT CASE
HWG HOT WATER GENERATOR
HWR HEATING WATER RETURN
HWS HEATING WATER SUPPLY
ILC IN-LINE CENTRIFICAL
IT INTERVAL TIMER
IN INCHES
INV INVERT
JB JUNCTION BOX
L LENGTH
LR LONG RADIUS
LAT LEAVING AIR TEMPERATURE
LCP LOCAL CONTROL PANEL
LDB LEAVING DRY BULB
LN LIQUID NITROGEN
LWB LEAVING WET BULB
LWT LEAVING WATER TEMPERATURE
LPS LOW PRESSURE STEAM
MAV MANUAL AIR VENT
MVD MANUAL VOLUME DAMPER
MAX MAXIMUM
MBH ONE THOUSAND BTUH PER HOUR
MCC MOTOR CONTROL CENTER
MIN MINIMUM
MH MAN HOLE
MP SUMP (MUD) PUMP
MPS MEDIUM PRESSURE STEAM
MPR MEDIUM PRESSURE RETURN
MTS MEDIUM TEMPERATURE SUPPLY
MTR MEDIUM TEMPERATURE RETURN
MUA MAKE-UP AIR
MUW MAKE-UP WATER
MZ MULTIZONE
NC NORMALLY CLOSED
NIC NOT IN CONTRACT
NO NORMALLY OPEN
NTS NOT TO SCALE
OA OUTSIDE AIR
OAD OUTSIDE AIR DAMPER
ODT OUTDOOR TEMPERATURE
PC PUMP CONDENSATE
PD PRESSURE DROP
PRV PRESSURE REDUCING VALVE
PWF PROPELLER WALL FAN
R REFRIGERANT
RA RETURN AIR
RAD RETURN AIR DAMPER
RAS RELIEF AIR SUPPLY
RP RECIRCULATING PUMP
RHG REFRIGERANT HOT GAS
RL REFRIGERANT LIQUID
RS REFRIGERANT SUCTION
RD ROOF DRAIN
RV RELIEF VALVE
SR SHORT RADIUS
OAL OUTSIDE AIR LOUVER
SAN SANITARY SEWER
SC SILL COCK
SCD SMOKE DAMPER
SD STORM DRAIN
SD SMOKE DETECTOR
SF SQUARE FEET
SDO STORM DRAIN OVERFLOW
SHC SENSIBLE HEAT CAPACITY
SP STAND PIPE
SP SUMP PUMP
SPS STATIC PRESSURE SENSOR
STA STATION
TR TEMPERED WATER RETURN
UG UNDERGROUND
VAC VACUUM PIPING
VDT VERTICAL DRAW THROUGH
VTR VENT THROUGH ROOF
WB WET BULB
O2 OXYGEN
?F DEGREES FAHRENHEIT
?C DEGREES CENTIGRADE
WM WATER METER
WL WATER LINE
WH WATER HEATER
WG WATER GAUGE
W WIDTH
W WASTE
VT VERTICAL TURBINE
VFD VARIABLE FREQUENCY DRIVE
VB VACUUM BREAKER
VAV VARIABLE AIR VOLUME
V VENT
UC UNDERCUT (DOOR - 3/4")
V- VALVE
TOS TOP OF STRUCTURE
TB THRUST BLOCK
T TEMPERED WATER
STR STRAINER
SP STATIC PRESSURE
SP SPRINKLER PIPE
SG SPECIALTY GAS
EUH ELECTRIC UNIT HEATER
RECIRCULATING
DHR DOMESTIC HOT WATER
TRANSMITTER
DPT DIFFERENTIAL PRESSURE
PER MINUTE
SCIM STANDARD CUBIC INCHES
TEMPERATURE
SST SATURATED SUCTION
(UNINSULATED)
TE TOP ELEVATION
(TOWER) PUMP
TP CONDENSER WATER
FSD FIRE/SMOKE DAMPER
EA EXHAUST AIR
MA MIXED AIR
AE ADJUSTABLE AIR EXTRACTOR
RAO RETURN AIR OPENING
AD AREA DRAIN/ACCESS DOOR
SINGLE LINE DUCT LEGEND
DUCT (SUPPLY, RETURN & EXHAUST)
SUPPLY DUCT UP
SUPPLY DUCT DOWN
RETURN OR EXHAUST DUCT UP
RETURN OR EXHAUST DUCT DOWN
DUCT RISE
DUCT DOWN
VOLUME DAMPER (MANUAL UNLESS INDICATED A.V.D.)
TRANSITION
DUCT TAKE-OFF (SEE SPEC. PERTAINING TO DEFLECTROLS)
TRANSITION (FLAT ON TOP)
TRANSITION (FLAT ON BOTTOM)
TRANSITION (TOP OR BOTTOM ONLY)
SUPPLY CEILING DIFFUSER
RETURN OR EXHAUST CEILING GRILLE
SIDEWALL SUPPLY
SIDEWALL RETURN
FLEXIBLE CONNECTION (DUCT)
RELIEF AIR SUPPLY TO TOILET
DUCT SPLIT WITH SPLITTER DAMPER
FLEX. DUCT WITH SCREW ON COLLAR, TAKE-OFF
DUCT WITH DUCT LINER
SQUARE ELBOW WITH TURNING VANES
RADIUS ELBOW (SEE SPECS. PERTAINING TO TURNING VANES)
AUTOMATIC VOLUME DAMPER
DN
R
12\10 SPLIT
OR
OR
SCD
FOB
T OR B
RAS
AVD
FD/SCD
FD
SMOKE CONTROL DAMPER
COMBINATION FIRE/SMOKE CONTROL DAMPER
FIRE DAMPER (FD)
FIRE DAMPER
SPS
SD
COMBINATION STARTER
STARTER
PIPE SLEEVE
CONCENTRIC REDUCER
PIPE ANCHOR
HVAC LEGEND
BALL VALVE WITH
3/4" HOSE END
BALANCE VALVE
THREADED & FLANGED
GLOBE VALVE
CHECK VALVE
3-WAY MIXING VALVE
BALL VALVE
BUTTERFLY VALVE
SOLENOID VALVE
CONTROL VALVE
PLAN VIEW
2-WAY MOTORIZED VALVE
RELIEF VALVE
FLANGED UNION
BRANCH OUT TOP
STRAINER
BRANCH OUT BOTTOM
ELBOW DOWN
ELBOW UP
TEE OUT TOP
BLIND FLANGE
PIPE CAP
AUTOMATIC AIR VENTAAV
FLEX. PIPE CONN.
BACKFLOW PREVENTER
THERMOMETER
TEE OUT BOTTOM
MANUAL AIR VENT
PIPE TEST PLUG
HEATING WATER FLOW
COLD WATER DOMESTIC
NATURAL GAS
CONDENSER WATER FLOW
DRAIN
HEATING WATER RETURN
HOT WATER DOMESTIC
G
D
DUCT SIZE FIRST DIMENSION
IS SIDE SHOWN
24\12
DOOR GRILLE
REFERS TO DETAIL OR
PLAN ON SHEET M-1.THERMOSTAT
INTERVAL TIMER
T
I.T.
1\M-4
DUCT/PLENUM w/LINER
FIRE DAMPER
ELBOW WITH
TURNING VANES
FLEX. DUCT CONN.
TURNING VANES
ELBOW WITHOUT
ADJUSTABLE AIR
EXTRACTOR
INSULATED FLEX. DUCT
INSULATED FLEX. DUCT
c
ECCENTRIC REDUCER
HWS
HWR
SCHS
SCHR
CONDENSER WATER RETURN
CS
CR
STATIC PRESSURE SENSOR
SMOKE DETECTOR
POINT OF CONNECTION
DUCT SPLIT
THREADED & FLANGED
THREADED & FLANGED
UNION
GAUGE TAPPING
GAUGE WITH TAPPING
THREADED & FLANGED
THREADED & FLANGED
PIPE SOCKET WELL
FLOW INDICATOR BALANCER
M
T G THERMOSTAT w/GROUND
ANNULAR ELEMENT FLOW STATION
M
DAMPER - BLADE VIEW DAMPER - END VIEW
xx{K OR xx/xx}K ROUND OR FLAT OVAL DUCT (K)
DOUBLE WALL INSULATED
ROUND OR FLAT OVAL DUCTxx{ OR xx/xx}
CHILLED WATER FLOW
CHILLED WATER RETURN
CHS
CHR
WATER SUPPLY
SECONDARY CHILLED
WATER RETURN
SECONDARY CHILLED
CV
CVA
CONSTANT VOLUME
ADJUSTABLE
CONSTANT VOLUME
CFM
PRESSURE SENSOR
SCHEDULE - HVAC
LEGENDS, &
ABBREVIATIONS,
FILE PATH:
SHEET NUMBER:
316 CORPORATE PARKWAY
NBP Engineers, Inc.
MACON, GEORGIA 31210
NBP
ENGINEERS
478-745-1691 www.nbpengineers.com
No. REVISIONS/SUBMISSIONS DATE
DRAWN:
CHECKED:
DESIGNED:
DATE:
PROJECT NUMBER:
P R
O J E
C T
T
IT
L E
SHEET TITLE:
CONSULTANTS
THIS DRAWING IS THE PROPERTY OF THE
ENGINEER AND MAY NOT BE REPRODUCED
OR USED IN WHOLE OR IN PART
WITHOUT HIS WRITTEN PERMISSION. IT IS
TO BE USED FOR THE PROJECT
SPECIFICALLY IDENTIFIED HEREIN AND TO
BE RETURNED UPON REQUEST.
P:\24012\24012mhh200.dgn
AS SHOWN
WSH
LTF
WSH
24012
08.13.24
P:\24012\24012mhh200.dgn
DATE PLOTTED
DGN FILE
13-AUG-2024
F o rt V a ll e y
G e o rg ia
COA Expiration: 6.30.2026
COA#PEF000774
NBP Engineers, Inc.
F V S
U P ro je c t
N o F
V S
U B
A S -9
T
M u lt i- B u il d in g s A u to m a ti o n S y s te m s P ro je c t
F o rt V a ll e y S ta te U n iv e rs it y
1 2 2 2 2 2
ELEVATOR LOBBY
A
B
MECH. RM.
EXIT LOBBY
MECH. RM.
E007
DATA RM.
01 1
ELECTRICAL
STAIR
LOWER LEVEL
MECH. RM.
MACHINE RM.
ELEVATOR
SWITCH RM.
TRANSFER
STORAGE
MECH. RM.
MECH. RM
CORRIDOR
CORRIDOR
SCALE:
= 1'-0
8 0 4 8 16
HUNTINGTON HALL - GROUND FLOOR PLAN - HVAC
MHH200
N
EXISTING
EWH-1
EXISTING
AHU-2
EXISTING
BCU-3
EXISTING
F-ELV-1
EXISTING
F-FP-1
EXISTING
P-CHW-A
EXISTING
P-CHW-B
EXISTING
BCU-2
EXISTING
BCU-1 EXISTING
AHU-1
EXISTING
ERV/OA-1
TT
T
MOD
EXISTING
CONTROLS
HVAC
EXISTING
CONTROLS
HVAC
EXISTING
HVAC CONTROLS
EXISTING
FLOOR PLAN - HVAC
GROUND
HUNTINGTON HALL -
NOTES:(THIS SHEET ONLY)
REPLACE EXISTING CONTROL PANEL AND ASSOCIATED CONTROLLER.
GENERAL NOTES:(THIS SHEET ONLY)
A
B
VERIFY ITEMS TO BE DEMOLISHED.
ALL CONDITIONS FOR NEW WORK MAY NOT BE SHOWN. SURVEY EXISTING CONDITIONS TO
MATCH EXISTING IF DAMAGED DURING CONSTRUCTION.
FINISHED SPACES. REPAIR/REPLACE ANY CEILING TILES, CEILING GRIDS, OR FIXTURES TO
REMOVE EXISTING CEILING TILES WHERE SCOPE OF WORK IS PERFORMED ABOVE
REPLACE EXISTING WALL MOUNTED TEMPERATURE SENSOR WITH NEW TEMPERATURE SENSOR.
FILE PATH:
SHEET NUMBER:
316 CORPORATE PARKWAY
NBP Engineers, Inc.
MACON, GEORGIA 31210
NBP
ENGINEERS
478-745-1691 www.nbpengineers.com
No. REVISIONS/SUBMISSIONS DATE
DRAWN:
CHECKED:
DESIGNED:
DATE:
PROJECT NUMBER:
P R
O J E
C T
T
IT
L E
SHEET TITLE:
CONSULTANTS
THIS DRAWING IS THE PROPERTY OF THE
ENGINEER AND MAY NOT BE REPRODUCED
OR USED IN WHOLE OR IN PART
WITHOUT HIS WRITTEN PERMISSION. IT IS
TO BE USED FOR THE PROJECT
SPECIFICALLY IDENTIFIED HEREIN AND TO
BE RETURNED UPON REQUEST.
P:\24012\24012mhh201.dgn
AS SHOWN
WSH
LTF
WSH
24012
08.13.24
P:\24012\24012mhh201.dgn
DATE PLOTTED
DGN FILE
13-AUG-2024
F o rt V a ll e y
G e o rg ia
COA Expiration: 6.30.2026
COA#PEF000774
NBP Engineers, Inc.
F V S
U P ro je c t
N o F
V S
U B
A S -9
T
M u lt i- B u il d in g s A u to m a ti o n S y s te m s P ro je c t
F o rt V a ll e y S ta te U n iv e rs it y
1 2 2 2 2 2
A
B
WORK ROOM
CORRIDOR
CORRIDOR
1 13
STAIR
1 14
MEN TOILET
GALLERY
ART EXHIBIT
CLOSET
COORDINATOR'S OFFICE
PRE-AWARD
COORDINATOR'S OFFICE
POST-AWARD
TECHNOLOGY OFFICE
INFORMATION
OFFICE
TITLE THREE
1 1 1
DATA CL.
1 10
JAN.
1 12
WOMEN TOILET
RECEPTIONIST
ENTRY LOBBY/
PORCH
LIFT
PLATFORM
VERT.
SCALE:
= 1'-0
8 0 4 8 16
HUNTINGTON HALL - FIRST FLOOR PLAN - HVAC
N
MHH201
T T
EXISTING
FCU-2
EXISTING
FCU-1
T
H
EXISTING
EWH
TT
EXISTING
FCU-4
EXISTING
FCU-3
EXISTING
EWH
TT
EXISTING
FCU-6
EXISTING
FCU-5
EXISTING
AC-1
ERV/OA-1
SMOKE DAMPER
EXISTING
FLOOR PLAN - HVAC
FIRST
HUNTINGTON HALL -
NOTES:(THIS SHEET ONLY)
SHUTDOWN SWITCH
EXISTING HVAC
REUSE
AHU-2
2 2
1 1
1 1
MATCH EXISTING IF DAMAGED DURING CONSTRUCTION.
FINISHED SPACES. REPAIR/REPLACE ANY CEILING TILES, CEILING GRIDS, OR FIXTURES TO
REMOVE EXISTING CEILING TILES WHERE SCOPE OF WORK IS PERFORMED ABOVE
GENERAL NOTES:(THIS SHEET ONLY)
A
B
VERIFY ITEMS TO BE DEMOLISHED.
ALL CONDITIONS FOR NEW WORK MAY NOT BE SHOWN. SURVEY EXISTING CONDITIONS TO
MATCH EXISTING IF DAMAGED DURING CONSTRUCTION.
FINISHED SPACES. REPAIR/REPLACE ANY CEILING TILES, CEILING GRIDS, OR FIXTURES TO
REMOVE EXISTING CEILING TILES WHERE SCOPE OF WORK IS PERFORMED ABOVE
REPLACE EXISTING WALL MOUNTED TEMPERATURE SENSOR WITH NEW TEMPERATURE SENSOR.
HUMIDITY SENSOR
REPLACE EXISTING
FILE PATH:
SHEET NUMBER:
316 CORPORATE PARKWAY
NBP Engineers, Inc.
MACON, GEORGIA 31210
NBP
ENGINEERS
478-745-1691 www.nbpengineers.com
No. REVISIONS/SUBMISSIONS DATE
DRAWN:
CHECKED:
DESIGNED:
DATE:
PROJECT NUMBER:
P R
O J E
C T
T
IT
L E
SHEET TITLE:
CONSULTANTS
THIS DRAWING IS THE PROPERTY OF THE
ENGINEER AND MAY NOT BE REPRODUCED
OR USED IN WHOLE OR IN PART
WITHOUT HIS WRITTEN PERMISSION. IT IS
TO BE USED FOR THE PROJECT
SPECIFICALLY IDENTIFIED HEREIN AND TO
BE RETURNED UPON REQUEST.
P:\24012\24012mhh202.dgn
AS SHOWN
WSH
LTF
WSH
24012
08.13.24
P:\24012\24012mhh202.dgn
DATE PLOTTED
DGN FILE
13-AUG-2024
F o rt V a ll e y
G e o rg ia
COA Expiration: 6.30.2026
COA#PEF000774
NBP Engineers, Inc.
F V S
U P ro je c t
N o F
V S
U B
A S -9
T
M u lt i- B u il d in g s A u to m a ti o n S y s te m s P ro je c t
F o rt V a ll e y S ta te U n iv e rs it y
1 2 2 2 2 2
A
B
VESTIBULE
STAIR
MEN TOILET
CLOSET
COORDINATOR'S OFFICE
PRE-AWARD
TECHNOLOGY OFFICE
INFORMATION
WOMEN TOILET
PORCH
CLOS.
DATA
21 1
ROOM
BREAK
CORRIDOR 1
CORRIDOR 2
CORRIDOR 3
ASST. OFFICE
DEVELOPMENT
AREA
RECEPTION
ROOM
COPY/WORK
OFFICE
EXTERNAL AFFAIRS
VICE PRESIDENT OF
LOUNGE
EXTERNAL AFFAIRS
VICE PRESIDENT OF
CONFERENCE ROOM
EXTERNAL AFFAIRS
VICE PRESIDENT OF
ASSISTANT
ADMINISTRATION
FILES/COPIER
CLOSET
CUSTOD.
205A
CLOSET
SCALE:
= 1'-0
8 0 4 8 16
HUNTINGTON HALL - SECOND FLOOR PLAN - HVAC
N
MHH202
T
FCU-8
EXISTING
FCU-7
EXISTING
T T T
EXISTING
T
FCU-9
EXISTING
FCU-10
TT
EXISTING EXISTING
FCU-12 FCU-1 1
EXISTING
AC-2
T
EXISTING
FCU-13
T
TBCU-2
BCU-1
BCU-3
FLOOR PLAN - HVAC
SECOND
HUNTINGTON HALL -
NOTES:(THIS SHEET ONLY)
GENERAL NOTES:(THIS SHEET ONLY)
A
B
VERIFY ITEMS TO BE DEMOLISHED.
ALL CONDITIONS FOR NEW WORK MAY NOT BE SHOWN. SURVEY EXISTING CONDITIONS TO
MATCH EXISTING IF DAMAGED DURING CONSTRUCTION.
FINISHED SPACES. REPAIR/REPLACE ANY CEILING TILES, CEILING GRIDS, OR FIXTURES TO
REMOVE EXISTING CEILING TILES WHERE SCOPE OF WORK IS PERFORMED ABOVE
CHW CONTROL VALVE ACTUATOR WITH NEW VALVE ACTUATOR.
REPLACE EXISTIGN FAN COIL UNIT CONTROLLER WITH NEW CONTOLLER. REPLACE EXISTING
1 1 1 1 1
FILE PATH:
SHEET NUMBER:
316 CORPORATE PARKWAY
NBP Engineers, Inc.
MACON, GEORGIA 31210
NBP
ENGINEERS
478-745-1691 www.nbpengineers.com
No. REVISIONS/SUBMISSIONS DATE
DRAWN:
CHECKED:
DESIGNED:
DATE:
PROJECT NUMBER:
P R
O J E
C T
T
IT
L E
SHEET TITLE:
CONSULTANTS
THIS DRAWING IS THE PROPERTY OF THE
ENGINEER AND MAY NOT BE REPRODUCED
OR USED IN WHOLE OR IN PART
WITHOUT HIS WRITTEN PERMISSION. IT IS
TO BE USED FOR THE PROJECT
SPECIFICALLY IDENTIFIED HEREIN AND TO
BE RETURNED UPON REQUEST.
P:\24012\24012mhh203.dgn
AS SHOWN
WSH
LTF
WSH
24012
08.13.24
P:\24012\24012mhh203.dgn
DATE PLOTTED
DGN FILE
13-AUG-2024
F o rt V a ll e y
G e o rg ia
COA Expiration: 6.30.2026
COA#PEF000774
NBP Engineers, Inc.
F V S
U P ro je c t
N o F
V S
U B
A S -9
T
M u lt i- B u il d in g s A u to m a ti o n S y s te m s P ro je c t
F o rt V a ll e y S ta te U n iv e rs it y
1 2 2 2 2 2
A
B
MEN TOILET
CLOSET
WOMEN TOILET
31 1
CLOS.
DATA
205A
CLOSET
PRESIDENT'S OFFICE
PRESIDENT'S SUITE
CORRIDOR
OFFICE
ASSISTANT'S
ADMIN.
LIBRARY
PRESIDENT'S
STORAGE
TOILET
PRESIDENT'S
RECEPTIONIST
PRINTER
FILE ROOM w/
WORK STUDY
ASSISTANT TO THE PRESIDENT
CORRIDOR
CONFERENCE RM.
BREAK ROOM
VEST.
CORRIDOR
J.C.
EXIST. STAIR
SCALE:
= 1'-0
8 0 4 8 16
HUNTINGTON HALL - THIRD FLOOR PLAN - HVAC
N
MHH203
VAV-3-3
T
T
VAV-3-4
TVAV-3-6 T VAV-3-8
EXISTING AC-3
T
VAV-3-1
T
VAV-3-7
T
VAV-3-5
T
VAV-3-2
FLOOR PLAN - HVAC
THIRD
HUNTINGTON HALL -
NOTES:(THIS SHEET ONLY)
GENERAL NOTES:(THIS SHEET ONLY)
A
B
VERIFY ITEMS TO BE DEMOLISHED.
ALL CONDITIONS FOR NEW WORK MAY NOT BE SHOWN. SURVEY EXISTING CONDITIONS TO
MATCH EXISTING IF DAMAGED DURING CONSTRUCTION.
FINISHED SPACES. REPAIR/REPLACE ANY CEILING TILES, CEILING GRIDS, OR FIXTURES TO
REMOVE EXISTING CEILING TILES WHERE SCOPE OF WORK IS PERFORMED ABOVE
FILE PATH:
SHEET NUMBER:
316 CORPORATE PARKWAY
NBP Engineers, Inc.
MACON, GEORGIA 31210
NBP
ENGINEERS
478-745-1691 www.nbpengineers.com
No. REVISIONS/SUBMISSIONS DATE
DRAWN:
CHECKED:
DESIGNED:
DATE:
PROJECT NUMBER:
P R
O J E
C T
T
IT
L E
SHEET TITLE:
CONSULTANTS
THIS DRAWING IS THE PROPERTY OF THE
ENGINEER AND MAY NOT BE REPRODUCED
OR USED IN WHOLE OR IN PART
WITHOUT HIS WRITTEN PERMISSION. IT IS
TO BE USED FOR THE PROJECT
SPECIFICALLY IDENTIFIED HEREIN AND TO
BE RETURNED UPON REQUEST.
P:\24012\24012mhh204.dgn
AS SHOWN
WSH
LTF
WSH
24012
08.13.24
P:\24012\24012mhh204.dgn
DATE PLOTTED
DGN FILE
13-AUG-2024
F o rt V a ll e y
G e o rg ia
COA Expiration: 6.30.2026
COA#PEF000774
NBP Engineers, Inc.
F V S
U P ro je c t
N o F
V S
U B
A S -9
T
M u lt i- B u il d in g s A u to m a ti o n S y s te m s P ro je c t
F o rt V a ll e y S ta te U n iv e rs it y
1 2 2 2 2 2
A
B
SCALE:
= 1'-0
8 0 4 8 16
HUNTINGTON HALL - ATTIC FLOOR PLAN - HVAC
N
MHH204
VAV-3-7
EXISTING
VAV-3-2
EXISTING
VAV-3-3
EXISTING
VAV-3-4
EXISTING
VAV-3-6
EXISTING
VAV-3-8
EXISTING
VAV-3-5
EXISTING
VAV-3-1
EXISTING
HVAC CONTROLS
EXISTING
EXISTING
AHU-3
EXISTING
AHU-4
MBLC
FLOOR PLAN - HVAC
ATTIC
HUNTINGTON HALL -
NOTES:(THIS SHEET ONLY)
GENERAL NOTES:(THIS SHEET ONLY)
A
VALVE ACTUATOR WITH NEW VALVE ACTUATOR.
REPLACE EXISTING TERMINAL UNIT CONTROLLER WITH NEW CONTROLLER. REPLACE EXISTING HW CONTROL
REPLACE EXISTING CONTROL PANEL AND ASSOCIATED CONTROLLERS.
REPLACE EXISTING TERMINAL UNIT CONTROLLER WITH NEW CONTROLLER.
FILE PATH:
SHEET NUMBER:
316 CORPORATE PARKWAY
NBP Engineers, Inc.
MACON, GEORGIA 31210
NBP
ENGINEERS
478-745-1691 www.nbpengineers.com
No. REVISIONS/SUBMISSIONS DATE
DRAWN:
CHECKED:
DESIGNED:
DATE:
PROJECT NUMBER:
P R
O J E
C T
T
IT
L E
SHEET TITLE:
CONSULTANTS
THIS DRAWING IS THE PROPERTY OF THE
ENGINEER AND MAY NOT BE REPRODUCED
OR USED IN WHOLE OR IN PART
WITHOUT HIS WRITTEN PERMISSION. IT IS
TO BE USED FOR THE PROJECT
SPECIFICALLY IDENTIFIED HEREIN AND TO
BE RETURNED UPON REQUEST.
P:\24012\24012mhh401.dgn
AS SHOWN
WSH
LTF
WSH
24012
08.13.24
P:\24012\24012mhh401.dgn
DATE PLOTTED
DGN FILE
13-AUG-2024
F o rt V a ll e y
G e o rg ia
COA Expiration: 6.30.2026
COA#PEF000774
NBP Engineers, Inc.
F V S
U P ro je c t
N o F
V S
U B
A S -9
T
M u lt i- B u il d in g s A u to m a ti o n S y s te m s P ro je c t
F o rt V a ll e y S ta te U n iv e rs it y
EXISTING TO REMAIN
DEMOLITION
NEW WORK
POINT OF CONNECTION
LINE LEGEND
NOT TO SCALE
TT
TT
CP-1
CHR CHR
CHS
C
H S
C H
R
SUCTION DIFFUSER
1" TO DOMESTIC WATER
SET 80#
RELIEF VALVE
CHEMICAL FEED TANK
AAV
AIR PURGER
FULL SIZE
EXTERIOR
INTERIOR MECH. ROOM
CHR-1
1"
CP-1
VALVE
3/4" DRAIN
EQUIPMENT
TO AIR HANDLING
STATION
MAKE-UP WATER
ACP
DDC PANEL
INPUT/OUTPUT
SUMMARIES
OUTPUTS INPUTS SOFTWARE
DIGITAL ANALOG ANALOG ALARM DDCDIGITAL ENERGY MGMT. LOGS
S Y
S T
M
G R
A P
H
IC
D
IS
P L
A Y
S T
A R
T
S T
O P
E N
A B
L E
D
IS
A B
L E
O P
E N
C L
O S
E
S T
A R
T
S T
O P
A
K E
U P
S E
T P
O
IN
T
J
U S
T
D
C
N T
R O
L
D
IF
F E
R E
N T
IA
L
P
R E S
S U
R E
P R
E S
S U
R E
S
W
IT
C H
A U
X
IL
IA
Y
N T
A C
T
A L
A
N T
A C
T
T E
M P
E R
A T
U R
E
H
IG
H
L
W
L
IM
IT
R U
N
T A
L
IZ
A T
IO
N
P R
O P
O R
T
IO
N A
L
P R
O P
IN
T E
G R
A L
T
IM
E
S
C H
E D
U L
E
S
S
O P
T
IM
A R
T
S T
O P
D A
Y
N
IG
T B
A C
K
D E
M A
IT
C Y
C L
E
R E S
T
IM
IZ
A T
IO
N
E C
O N
O M
IZ
E R
N O
T E S
C U
R R
E
L A
Y
S P
E E
D
IN
D
IC
A T
IO
N
S P
E
N T
R O
L
P O
S
IT
IO
N
IN
D
IC
A T
IO
N
O P
E N
C L
O S
S
IT
IO
N
P A
D D
L E
S
W
IT
C H
O P
E R
A T
A T
U S
D
IF
F
P
R E S
S U
R E
P R
E S
S U
R E
S T
A T
U S
K W
H
T R
E
G
W A
T
F
O W
G A
L
F A
IL
U
D E (S
T E S
A
N D
1. FAILURE MODES:
2. WHERE FAILURE MODE IS INDICATED, THE INDICATED POSITION SHALL OCCUR ON INTERRUPTION OF ELECTRIC POWER TO THE DDC PANEL
L - LAST COMMAND
O - OPEN OR ON
C - CLOSE OR OFF
NOTES:
C
C
TAG
CHR-1
TT-1
TT-2
EM-1
POINT DESCRIPTION
CHILLER
ELECTRIC METER - MAIN
BUILDING UTILITY MONITORING
A1
DO DI
EXISTING PURGE VALVE
A1
FM-DW
FM-GAS GAS METER
DW METER
G
O W
C C
F
MHL401
EXISTING
EXISTING
EXISTING
EXISTING
EXISTING
NEW
NEW EXISTING
EXISTING
EXISTING
EQUIPMENT
TO AIR HANDLING
CHW SUPPLY (SYSTEM) (NEW)
CHW RETURN (SYSTEM) (NEW)
CP-2
CP-2
DO DI
HVAC
FLOW DIAGRAM -
CHILLED WATER
HUNTINGTON HALL -
HUNTINGTON HALL - CHILLED WATER FLOW DIAGRAM - HVAC
3"
3"
3"
3"
3"
3"
3"
CHILLER SYSTEM
HUNTINGTON HALL
CP-1, CP-2 CHILLER PUMPS
20 PSIG INITIAL FILL PRESSURE VOLUME
DIAPHRAM EXPANSION TANK.
FILE PATH:
SHEET NUMBER:
316 CORPORATE PARKWAY
NBP Engineers, Inc.
MACON, GEORGIA 31210
NBP
ENGINEERS
478-745-1691 www.nbpengineers.com
No. REVISIONS/SUBMISSIONS DATE
DRAWN:
CHECKED:
DESIGNED:
DATE:
PROJECT NUMBER:
P R
O J E
C T
T
IT
L E
SHEET TITLE:
CONSULTANTS
THIS DRAWING IS THE PROPERTY OF THE
ENGINEER AND MAY NOT BE REPRODUCED
OR USED IN WHOLE OR IN PART
WITHOUT HIS WRITTEN PERMISSION. IT IS
TO BE USED FOR THE PROJECT
SPECIFICALLY IDENTIFIED HEREIN AND TO
BE RETURNED UPON REQUEST.
P:\24012\24012mhh402.dgn
AS SHOWN
WSH
LTF
WSH
24012
08.13.24
P:\24012\24012mhh402.dgn
DATE PLOTTED
DGN FILE
13-AUG-2024
F o rt V a ll e y
G e o rg ia
COA Expiration: 6.30.2026
COA#PEF000774
NBP Engineers, Inc.
F V S
U P ro je c t
N o F
V S
U B
A S -9
T
M u lt i- B u il d in g s A u to m a ti o n S y s te m s P ro je c t
F o rt V a ll e y S ta te U n iv e rs it y
EXISTING TO REMAIN
DEMOLITION
NEW WORK
POINT OF CONNECTION
LINE LEGEND
MHH402
NOT TO SCALE
DDC PANELS
INPUT/OUTPUT
SUMMARIES
ACP
O
C
C
C
AH-CV SYSTEM
HUNTINGTON HALL
HUNTINGTON HALL - AH-CV SYSTEM FLOW DIAGRAM - HVAC
ELECTRIC HEATING COIL
NOTES:
1. FAILURE MODES:
2. WHERE FAILURE MODE IS INDICATED, THE INDICATED POSITION SHALL OCCUR ON INTERRUPTION OF
ELECTRIC POWER TO THE DDC PANEL.
L - LAST COMMAND
O - OPEN OR ON
C - CLOSE OR OFF
PERCENTAGE DESIGN FLOW-HEATING
PERCENTAGE DESIGN FLOW-COOLING
TAG
FAR
ZONE-SPACE TEMP.
CC-L.A.T.
L.L.-TEMP.
T-XX
RA 1
FMS 1
OA 1
TT 2
TT 3
TT 4
TT 5
LL 1
SPS 1
TT 1
SA-VFD
EDH-L.A.T.
TT OA
DP 1 BUILDING PRESSURE
HT OA
HT RA
TT 8 EDH-2 LAT
AH-1 & AH-2
EHC
S Y
S T
A P
P L
A Y
S T
A R
T
S T
O P
E N
A B
L E
D
IS
A B
L E
O P
E N
C L
O S
E
S T
A R
T
S T
K E
U P
S E
T P
O
J
U S
T
D
N T
R O
L
D
IF
F E
R E
N T
IA
L
P
R E S
S U
R E
P R
E S
S U
R E
S
W
IT
C H
A U
X
IL
IA
N T
A C
T
A L
A
N T
A C
T
T E
M P
E R
A T
U R
E
R E
L A
T
IV
M
ID
IT
Y
P R
E S
S U
R E
H
IG
H
L
IT
R
T A
L
IZ
A T
IO
N
P R
O P
O R
T
IO
N A
L
P R
O P
IN
T E
G R
A L
T
IM
E
S
C H
E D
U L
E
S
S
O P
T
IM
A R
T
S T
O P
D A
Y
N
IG
T B
A C
K
D E
M A
IT
C Y
C L
E
R E S
T
IM
IZ
A T
IO
N
E C
O N
O M
IZ
E R
N O
T E S
C U
R R
E
L A
Y
D R
IV
E
S
T A
T U
S
S P
E E
D
IN
D
IC
A T
IO
N
S P
E
N T
R O
L
E
IT
C H
C O
C A
L C
U L
A T
IN
T
P O
S
IT
IO
N
IN
D
IC
A T
IO
N
O P
E N
C L
O S
S
IT
IO
N
T R
E
G
S T
A T
U S
IR
O W
W A
T
O W
F A
IL
U
D E (S
T E S
A
N D
ANALOGDIGITAL DIGITAL ANALOG ALARM DDC ENERGY MGMT. LOGS
SOFTWAREINPUTSOUTPUTS
VLV
FAR
AI
TT
SPS
AI
R
SAF
VFD
VFD
FAR
FIL
AHU AHU
AIDIAO DO
EHC
AHU
CC
RA
TT
HT
RAD
AI AI
AIAO
O .A
TT
TT
TT
AIAI AIC
H S
C H
R
LL
DI
AI
EHC
TT
AI
DP
HT
EXTERIOR WALL
AO
AO
OA
AIAO
S.A. FAN
AH-1 & AH-2
HVAC
FLOW DIAGRAM -
AH-CV SYSTEM
HUNTINGTON HALL -
AIAO
NEW
NEW NEW
SA
SD
FROM ERU
NEW
RA
RA
NEW NEW
NEW
OA
OA
NEW
NEW
NEW
EXISTING VFD
CONNECT TO
NEW NEW NEW NEW
SAFAN-VFD
FA RELAY
RA TEMP.
MA TEMP.
SA-TEMP.
GLOBAL OA TEMP.
GLOBAL OA RH
RA-RH
SA-SPS
MIN. OA DAMPER
MIN. OA FMS
RA DAMPER
FILE PATH:
SHEET NUMBER:
316 CORPORATE PARKWAY
NBP Engineers, Inc.
MACON, GEORGIA 31210
NBP
ENGINEERS
478-745-1691 www.nbpengineers.com
No. REVISIONS/SUBMISSIONS DATE
DRAWN:
CHECKED:
DESIGNED:
DATE:
PROJECT NUMBER:
P R
O J E
C T
T
IT
L E
SHEET TITLE:
CONSULTANTS
THIS DRAWING IS THE PROPERTY OF THE
ENGINEER AND MAY NOT BE REPRODUCED
OR USED IN WHOLE OR IN PART
WITHOUT HIS WRITTEN PERMISSION. IT IS
TO BE USED FOR THE PROJECT
SPECIFICALLY IDENTIFIED HEREIN AND TO
BE RETURNED UPON REQUEST.
P:\24012\24012mhh403.dgn
AS SHOWN
WSH
LTF
WSH
24012
08.13.24
P:\24012\24012mhh403.dgn
DATE PLOTTED
DGN FILE
13-AUG-2024
F o rt V a ll e y
G e o rg ia
COA Expiration: 6.30.2026
COA#PEF000774
NBP Engineers, Inc.
F V S
U P ro je c t
N o F
V S
U B
A S -9
T
M u lt i- B u il d in g s A u to m a ti o n S y s te m s P ro je c t
F o rt V a ll e y S ta te U n iv e rs it y
EXISTING TO REMAIN
DEMOLITION
NEW WORK
POINT OF CONNECTION
LINE LEGEND
MHH403
NOT TO SCALE
HUNTINGTON HALL - AHU FLOW DIAGRAM - HVAC
HVAC
AHU FLOW DIAGRAM -
HUNTINGTON HALL -
S T
A P
P L
A Y
S T
A R
T
S T
O P
E N
A B
L E
D
IS
A B
L E
O P
E N
C L
O S
E
S T
A R
T
S T
K E
U P
S E
T P
O
J
U S
T
D
N T
R O
L
D
IF
F E
R E
N T
IA
L
P
R E S
S U
R E
P R
E S
S U
R E
S
W
IT
C H
A U
X
IL
IA
N T
A C
T
A L
A
N T
A C
T
T E
M P
E R
A T
U R
E
R E
L A
T
M
ID
IT
Y
P R
E S
S U
R E
H
IG
H
L
IT
R
T A
L
IZ
A T
IO
N
P R
O P
O R
T
IO
N A
L
P R
O P
IN
T E
G R
A L
T
IM
E
S
C H
E D
U L
E
S
S
O P
T
IM
A R
T
S T
O P
D A
Y
N
IG
T B
A C
K
D E
M A
IT
C Y
C L
E
R E S
T
IM
IZ
A T
IO
N
E C
O N
O M
IZ
E R
F A
IL
U
D E (S
T E S
A
N D
N O
T E S
OUTPUTS INPUTS SOFTWARE
DDC PANELS
INPUT/OUTPUT
SUMMARIES
DIGITAL ANALOG ANALOG ALARM DDCDIGITAL
C U
R R
E
L A
Y
D R
IV
E
S
T A
T U
S
S P
E E
D
IN
D
IC
A T
IO
N
S P
E
N T
R O
L
E
IT
C H
C O
PRIMARY AIR FLOW
O
NOTES:
1. FAILURE MODES:
2. WHERE FAILURE MODE IS INDICATED, THE INDICATED POSITION SHALL OCCUR ON INTERRUPTION OF
ELECTRIC POWER TO THE DDC PANEL.
L - LAST COMMAND
C A
L C
U L
A T
IN
T
C
O - OPEN OR ON
C - CLOSE OR OFF
PERCENTAGE DESIGN FLOW-HEATING
PERCENTAGE DESIGN FLOW-COOLING
TAG
FAR
TUC-XX
TUC-XX
TUC-XX
ZONE-SPACE TEMP.
SAT
CC-L.A.T.
L.L.-TEMP.
T-XX
P O
S
IT
IO
N
IN
D
IC
A T
IO
N
O P
E N
C L
O S
S
IT
IO
N
ACP
C
RA 1
FMS 1
OA 1
TT 2
TT 3
TT 4
TT 5
LL 1
SPS 1
L
T R
E
G
ENERGY MGMT. LOGS
S T
A T
U S
AIR TERMINAL UNITS (TU)
TT 1
AH-4
SA-VFD
ELECTRIC HEATING COIL-SCR C
PHC-L.A.T.
TT OA
ELECTRIC HEATER-SCR C
DP 1 BUILDING PRESSURE
HT OA
HT RA
O W
W A
T
O W
FM-1 CHW FLOW
TT
AO
AI
DP
EXTERIOR WALL
AO
HT
R
TT
LL
TT
RA
TT
T
TUC
ZONE
COND.
T
TUC
ZONE
COND.
TU-X
TU-XX
AHU AHU
AIAI DI
AI
AI
AO AI
AO AI
AI
AI
AO AI
RAD AH-1
SCR
SCR
C H S
C H
R
T-XX
T-XX
AO AI
OA
AI
HT
O A
RA
RA
EXISTING
SA FAN
SA
SD
EXISTING
EXISTING
OA
OA
SAF
VFD
VFD
FAR
AIDIAODO
CCFIL
NEW
TU-X
SAT
NEW
SPS
AI
NEW
AI
TU-X
SAT
NEW
NEW
FAR
TT
AI
NEW
EXISTING VFD
CONNECT TO
NEWNEW NEW
NEW ACTUATOR
NEW ACTUATOR
NEW NEW
NEW
NEW
NEW
AH-VAV SYSTEM
HUNTINGTON HALL
PHC
AO AI
VLV
AHU
CC
SCR
AO
TT
AI
NEW
FROM ERU NEW ACTUATOR
MIN. OA DAMPER
MIN. OA FMS
SA FAN-VFD
FA RELAY
RA DAMPER
RA TEMP.
MA TEMP.
SA-TEMP.
GLOBAL OA TEMP.
GLOBAL OA RH
RA-RH
SA-SPS
SA DAMPER ACTUATOR
SA TEMP. TO ZONE
FILE PATH:
SHEET NUMBER:
316 CORPORATE PARKWAY
NBP Engineers, Inc.
MACON, GEORGIA 31210
NBP
ENGINEERS
478-745-1691 www.nbpengineers.com
No. REVISIONS/SUBMISSIONS DATE
DRAWN:
CHECKED:
DESIGNED:
DATE:
PROJECT NUMBER:
P R
O J E
C T
T
IT
L E
SHEET TITLE:
CONSULTANTS
THIS DRAWING IS THE PROPERTY OF THE
ENGINEER AND MAY NOT BE REPRODUCED
OR USED IN WHOLE OR IN PART
WITHOUT HIS WRITTEN PERMISSION. IT IS
TO BE USED FOR THE PROJECT
SPECIFICALLY IDENTIFIED HEREIN AND TO
BE RETURNED UPON REQUEST.
P:\24012\24012mhh404.dgn
AS SHOWN
WSH
LTF
WSH
24012
08.13.24
P:\24012\24012mhh404.dgn
DATE PLOTTED
DGN FILE
13-AUG-2024
F o rt V a ll e y
G e o rg ia
COA Expiration: 6.30.2026
COA#PEF000774
NBP Engineers, Inc.
F V S
U P ro je c t
N o F
V S
U B
A S -9
T
M u lt i- B u il d in g s A u to m a ti o n S y s te m s P ro je c t
F o rt V a ll e y S ta te U n iv e rs it y
EXISTING TO REMAIN
DEMOLITION
NEW WORK
POINT OF CONNECTION
LINE LEGEND
NOT TO SCALE
S T
A P
P L
A Y
S T
A R
T
S T
O P
E N
A B
L E
D
IS
A B
L E
O P
E N
C L
O S
E
S T
A R
T
S T
K E
U P
S E
T P
O
J
U S
T
D
N T
R O
L
D
IF
F E
R E
N T
IA
L
P
R E S
S U
R E
P R
E S
S U
R E
S
W
IT
C H
A U
X
IL
IA
N T
A C
T
A L
A
N T
A C
T
T E
M P
E R
A T
U R
E
R E
L A
T
M
ID
IT
Y
P R
E S
S U
R E
S T
A T
U S
IN
T E
R L
O C
K
H
IG
H
L
IT
R
T A
L
IZ
A T
IO
N
P R
O P
O R
T
IO
N A
L
P R
O P
IN
T E
G R
A L
T
IM
E
S
C H
E D
U L
E
S
S
O P
T
IM
A R
T
S T
O P
D A
Y
N
IG
T B
A C
K
D E
M A
IT
C Y
C L
E
R E S
T
IM
IZ
A T
IO
N
E C
O N
O M
IZ
E R
F A
IL
U
D E (S
T E S
A
N D
N O
T E S
OUTPUTS INPUTS SOFTWARE
DDC PANELS
INPUT/OUTPUT
SUMMARIES
DIGITAL ANALOG ANALOG ALARM DDC ENERGY MGMT.DIGITAL
C U
R R
E
L A
Y
D R
IV
E
S
T A
T U
S
S P
E E
D
IN
D
IC
A T
IO
N
S P
E
N T
R O
L
E
IT
C H
C O
O W
C
NOTES:
1. FAILURE MODES:
2. WHERE FAILURE MODE IS INDICATED, THE INDICATED POSITION SHALL OCCUR ON INTERRUPTION OF
ELECTRIC POWER TO THE DDC PANEL.
L - LAST COMMAND
C A
L C
U L
A T
IN
T
O - OPEN OR ON
C - CLOSE OR OFF
TAG
FAR
TT 1
P O
S
IT
IO
N
IN
D
IC
A T
IO
N
O P
E N
C L
O S
S
IT
IO
N
CHR
CHS
T
R
FC FC
ACP
SAF
T ZONE-SPACE TEMP.
T R
E
G S
FC
T
SAF SUPPLY FAN C
HC
FAN COIL-TYPICAL
A1
FAN COIL - FC
VLV 1 CC CONTROL VALVE
C
MVD
A1
FILTER
TT
TT
TT
AH AH
S T
A P
P L
A Y
S T
A R
T
S T
O P
E N
A B
L E
D
IS
A B
L E
O P
E N
C L
O S
E
S T
A R
T
S T
K E
U P
S E
T P
O
J
U S
T
D
N T
R O
L
D
IF
F E
R E
N T
IA
L
P
R E S
S U
R E
P R
E S
S U
R E
S
W
IT
C H
A U
X
IL
IA
N T
A C
T
A L
A
N T
A C
T
T E
M P
E R
A T
U R
E
R E
L A
T
M
ID
IT
Y
P R
E S
S U
R E
S T
A T
U S
IN
T E
R L
O C
K
H
IG
H
L
IT
R
T A
L
IZ
A T
IO
N
P R
O P
O R
T
IO
N A
L
P R
O P
IN
T E
G R
A L
T
IM
E
S
C H
E D
U L
E
S
S
O P
T
IM
A R
T
S T
O P
D A
Y
N
IG
T B
A C
K
D E
M A
IT
C Y
C L
E
R E S
T
IM
IZ
A T
IO
N
E C
O N
O M
IZ
E R
F A
IL
U
D E (S
T E S
A
N D
N O
T E S
OUTPUTS INPUTS SOFTWARE
DDC PANELS
INPUT/OUTPUT
SUMMARIES
DIGITAL ANALOG ANALOG ALARM DDC ENERGY MGMT.DIGITAL
C U
R R
E
L A
Y
D R
IV
E
S
T A
T U
S
S P
E E
D
IN
D
IC
A T
IO
N
S P
E
N T
R O
L
E
IT
C H
C O
O W
C
C
O
NOTES:
1. FAILURE MODES:
2. WHERE FAILURE MODE IS INDICATED, THE INDICATED POSITION SHALL OCCUR ON INTERRUPTION OF
ELECTRIC POWER TO THE DDC PANEL.
L - LAST COMMAND
C A
L C
U L
A T
IN
T
O - OPEN OR ON
C - CLOSE OR OFF
TAG
FAR
HT 2
P O
S
IT
IO
N
IN
D
IC
A T
IO
N
O P
E N
C L
O S
S
IT
IO
N
ACP
FAR
TT
HT
TT
FAR
HT
TT
FILTER
TT
HT
T R
E
G S
C
C
OA 1
EA 1
SF
EF EXHAUST FAN
SUPPLY FAN
TT 1
TT 2
TT 3
TT 4
TT 5
TT 6
HT 1
VLV 1
ERU-1
HTX MODULE
CC
C H S
C H
R
AH-1 AND FAN COILS
TO BUILDING DISTRIBUTION
EHC
A1 A1
A1A1
EHC
SA
R FAR
EA
A1
OA
A1
A1
EA
HUNTINGTON HALL - FAN COIL UNITS FLOW DIAGRAM - HVAC
NOT TO SCALE
HUNTINGTON HALL - ERU UNITS FLOW DIAGRAM - HVAC
FLOW DIAGRAM - HVAC
FAN COIL & ERU UNITS
HUNTINGTON HALL -
SA FAN
EXISTING
EXISTING
OA
RA
MIXING PLENUM
EXISTING COMMON
SD
OA FROM ERU-1
SA
VLV
A0 A1
FAR
TUC
TTFAR
CONDITIONED ZONE
EXISTING
CCFIL
OA
OA
OA ISOLATION DAMPER (2-POS.)
GLOBAL OA TEMP
GLOBAL OA RH
TT OA
HT OA
OA CONDITIONS
OA
OA
OAL
EA
EAL
EA
EA
SA
FAN
EA
FAN
SA
SD SD
E A
S A
HUNTINGTON HALL
FAN COIL UNITS
EHC ELECTRIC HEAT COIL
AO
EHC
HUNTINGTON HALL
ENERGY RECOVERY UNIT
ERV/OA-1
TT 7
C.C. CONTROL VALVE
ELECTRIC HEAT COIL
AO
EHC
TT
VLV
A0 A1
NEW
NEW
NEW
NEW
NEW
NEW ACTUATOR
NEW
NEW
NEW
NEW
A1A1 A1 A1
NEW NEW
NEW ACTUATOR
NEW ACTUATOR
NEW
NEW
NEW
SA TEMP.
FA RELAY
NEW ACTUATOR
EA ISOLATION DAMPER (2-POS.)
HTX-EAT SUPPLY
HTX-LAT SUPPLY
CC-LAT
UNIT-LAT SUPPLY
HTX-LAT EXHAUST
EHC LAT
UNIT-EAT EXHAUST
FA RELAY
SA-RH
EA-RH
MHH404
FILE PATH:
SHEET NUMBER:
316 CORPORATE PARKWAY
NBP Engineers, Inc.
MACON, GEORGIA 31210
NBP
ENGINEERS
478-745-1691 www.nbpengineers.com
No. REVISIONS/SUBMISSIONS DATE
DRAWN:
CHECKED:
DESIGNED:
DATE:
PROJECT NUMBER:
P R
O J E
C T
T
IT
L E
SHEET TITLE:
CONSULTANTS
THIS DRAWING IS THE PROPERTY OF THE
ENGINEER AND MAY NOT BE REPRODUCED
OR USED IN WHOLE OR IN PART
WITHOUT HIS WRITTEN PERMISSION. IT IS
TO BE USED FOR THE PROJECT
SPECIFICALLY IDENTIFIED HEREIN AND TO
BE RETURNED UPON REQUEST.
P:\24012\24012mhl200.dgn
AS SHOWN
WSH
LTF
WSH
24012
08.13.24
P:\24012\24012mhl200.dgn
DATE PLOTTED
DGN FILE
13-AUG-2024
F o rt V a ll e y
G e o rg ia
COA Expiration: 6.30.2026
COA#PEF000774
NBP Engineers, Inc.
F V S
U P ro je c t
N o F
V S
U B
A S -9
T
M u lt i- B u il d in g s A u to m a ti o n S y s te m s P ro je c t
F o rt V a ll e y S ta te U n iv e rs it y
B
BCDEF
S T
A
IR
B
R O
O M
M A
C H
IN
E
E L
E V
A T
O R
B
C O
R R
ID
O R
B
J A
N
IT
O
'S
O R
ELEC.
A R
E A
W A
Y
SCALE:
= 1'-0
8 0 4 8 16
HUNT LIBRARY - BASEMENT FLOOR PLAN - HVAC
N
FLOOR PLAN - HVAC
BASEMENT
HUNT LIBRARY -
HP-1
CP-1
BOILER
VFD-1
ACP
VFD-2
T
HW
T
EF-1 1
UH-1
EF-10
T
AIR COMPRESSOR
EXISTING CONTROL
CONCRETE PAD
EXISTING
CHEMICAL WATER TREATMENT
EXISTING CONTROL PANEL
CONCRETE PAD
EXISTING
SUPPORT BEAMS B.E. 10'-8"
EXISTING GRATING
SF-1
RF-1
T
EF-1 1
EXISTING
EXISTING
EXISTING
EXISTING
EXISTING
EXISTING
EXISTING EXISTING
EXISTING
EXISTING
EXISTING
EXISTING
EXISTING
STARTERS
EXISTING
AIR COOLED CHILLER
EXISTING
BP
INTAKE LOUVER
EXISTING OA
NOTES:(THIS SHEET ONLY)
EXISTING OUTSIDE AIR DAMPER TO REMAIN. REPLACE ACTUATOR. MINIMUM OUTSIDE AIR 9,500 CFM.
EXISTING SMOKE ISOLATION DAMPER TO REMAIN. PROVIDE NEW ACTUATOR.
PROVIDE NEW WALL TEMPERATURE SENSOR.
REPLACE EXISTING HW CONTROL VALVE WITH NEW ACTUATOR.
MHL200
5 REPLACE EXISTING CONTROL PANEL AND EXISTING CONTROLLERS.
GENERAL NOTES:(THIS SHEET ONLY)
A
VERIFY ITEMS TO BE DEMOLISHED.
ALL CONDITIONS FOR NEW WORK MAY NOT BE SHOWN. SURVEY EXISTING CONDITIONS TO
FILE PATH:
SHEET NUMBER:
316 CORPORATE PARKWAY
NBP Engineers, Inc.
MACON, GEORGIA 31210
NBP
ENGINEERS
478-745-1691 www.nbpengineers.com
No. REVISIONS/SUBMISSIONS DATE
DRAWN:
CHECKED:
DESIGNED:
DATE:
PROJECT NUMBER:
P R
O J E
C T
T
IT
L E
SHEET TITLE:
CONSULTANTS
THIS DRAWING IS THE PROPERTY OF THE
ENGINEER AND MAY NOT BE REPRODUCED
OR USED IN WHOLE OR IN PART
WITHOUT HIS WRITTEN PERMISSION. IT IS
TO BE USED FOR THE PROJECT
SPECIFICALLY IDENTIFIED HEREIN AND TO
BE RETURNED UPON REQUEST.
P:\24012\24012mhl201.dgn
AS SHOWN
WSH
LTF
WSH
24012
08.13.24
P:\24012\24012mhl201.dgn
DATE PLOTTED
DGN FILE
13-AUG-2024
F o rt V a ll e y
G e o rg ia
COA Expiration: 6.30.2026
COA#PEF000774
NBP Engineers, Inc.
F V S
U P ro je c t
N o F
V S
U B
A S -9
T
M u lt i- B u il d in g s A u to m a ti o n S y s te m s P ro je c t
F o rt V a ll e y S ta te U n iv e rs it y
1 2 3 4 5 6 7
UP
DN
UP
F
E
D
C
B
A
JAN.
OFFICE OFFICE
OFFICE
SHAFT
MECH.
MEN
WOMEN
STOR.
STOR.
WORK ROOM
SHIPPING-RECEIVING
HALL
OFFICE
CIR-RES
RESERVE
CIRCULATION-
KITCHENET
SECRETARY
OFFICE
ACQUISITIONS
TECHNICAL SERVICES
OFFICES
ADMINISTRATION
CORR.
COMPUTER LAB.
LOUNGE
LIBRARIAN'S
STOR.
MICROFORM READERS
# 2
ELEV.
# 1
ELEV.
STOR.
STOR.
STOR.
STOR.
CORR.
STOR.
133134
# 2
STAIR
# 1
STAIR
LIBRARIAN
REFERENCE
LOAN OFFICE
INTLIB.
CLOSET
H.TOIL.
H.TOIL.
138A
VESTIBULE
STORAGE
MEN'S TOILET
WOMEN'S TOILET
AH-1
TU1-4
TU1-6 TU1-5
TU1-2
TU1-1
TU1-8
TU1-7
TU1-9
TU1-10
TU1-12
TU1-13
TU1-15
TU1-14
TU1-16
TU1-18
TU1-17
TU1-3
T
T T
T
TT
T
T
T
T
T
T
TT
T
TU1-52
T TU1-54
T
T T
T
T
TT
CABINET HEATER
EXISTING
EXISTING FIN TUBE RADIANT HEATERS
CABINET HEATER
EXISTING
HUNT LIBRARY - FIRST FLOOR PLAN - HVAC
HVAC
FIRST FLOOR PLAN -
HUNT LIBRARY -
SCALE:
= 1'-0
8 0 4 8 16
EXISTING FIN TUBE
EXISTING FIN TUBE
CABINET HEATER
EXISTING
TU1-1 1
EF-7
EXISTING
EF-7
EXISTING
EF-8
EXISTING
EF-6
EXISTING
MOTORIZED
DAMPER
BALANCE
EXISTING
EXISTING
EXISTING
EXISTING
EXISTING
EXISTING
EXISTING
EXISTING
EXISTING
EXISTING
EXISTING
EXISTING
EXISTING
EXISTING
EXISTING
EXISTING
EXISTING
EXISTING
EXISTING
EXISTING
EXISTING EXISTING
TU1-56
EXISTING
N
EXISTING FIN TUBE RADIANT HEATERS
PANEL "HE"
PANEL "E"
PANEL "F"
NOTES:(THIS SHEET ONLY)
VALVE ACTUATOR WITH NEW VALVE ACTUATOR.
REPLACE EXISTING TERMINAL UNIT CONTROLLER WITH NEW CONTROLLER. REPLACE EXISTING HW CONTROL
3 REPLACE EXISTING HW CONTROL VALVE ACTUATOR WITH NEW ACTUATOR.
T
T
2 2
1 1
GENERAL NOTES:(THIS SHEET ONLY)
A
B
VERIFY ITEMS TO BE DEMOLISHED.
ALL CONDITIONS FOR NEW WORK MAY NOT BE SHOWN. SURVEY EXISTING CONDITIONS TO
MATCH EXISTING IF DAMAGED DURING CONSTRUCTION.
FINISHED SPACES. REPAIR/REPLACE ANY CEILING TILES, CEILING GRIDS, OR FIXTURES TO
REMOVE EXISTING CEILING TILES WHERE SCOPE OF WORK IS PERFORMED ABOVE
MHL201
FILE PATH:
SHEET NUMBER:
316 CORPORATE PARKWAY
NBP Engineers, Inc.
MACON, GEORGIA 31210
NBP
ENGINEERS
478-745-1691 www.nbpengineers.com
No. REVISIONS/SUBMISSIONS DATE
DRAWN:
CHECKED:
DESIGNED:
DATE:
PROJECT NUMBER:
P R
O J E
C T
T
IT
L E
SHEET TITLE:
CONSULTANTS
THIS DRAWING IS THE PROPERTY OF THE
ENGINEER AND MAY NOT BE REPRODUCED
OR USED IN WHOLE OR IN PART
WITHOUT HIS WRITTEN PERMISSION. IT IS
TO BE USED FOR THE PROJECT
SPECIFICALLY IDENTIFIED HEREIN AND TO
BE RETURNED UPON REQUEST.
P:\24012\24012mhl202.dgn
AS SHOWN
WSH
LTF
WSH
24012
08.13.24
P:\24012\24012mhl202.dgn
DATE PLOTTED
DGN FILE
13-AUG-2024
F o rt V a ll e y
G e o rg ia
COA Expiration: 6.30.2026
COA#PEF000774
NBP Engineers, Inc.
F V S
U P ro je c t
N o F
V S
U B
A S -9
T
M u lt i- B u il d in g s A u to m a ti o n S y s te m s P ro je c t
F o rt V a ll e y S ta te U n iv e rs it y
1 2 3 4 5 6 7
F
E
D
C
B
A
DN
UP
DN
JAN.
SHAFT
MECH.
VAULT
READING ROOM
FACULTY STUDIES
COPY
STOR.
F.S.
F.S.
F.S.
F.S.
F.S.
F.S.
F.S.
MEN,S TOILET
WOMEN,S TOILET
G.S.
G.S.
G.S.
G.S.
G.S.
G.S.
G.S.
G.S.
G.S.
G.S.
G.S.
G.S.
G.S.
STOR.
TRAINING
CONF.
CLASSROOM
# 2
ELEV.
# 2
STAIR # 1
STAIR
# 1
ELEV.
HALL
FOYER
STORAGE
BOOK
ROOM
WORK
OFFICE
201A
201B
COLLECTION
HERITAGE
201C
COLLECTION
HERITAGE
SCALE:
= 1'-0
8 0 4 8 16
HUNT LIBRARY - SECOND FLOOR PLAN - HVAC
HVAC
FLOOR PLAN -
SECOND
HUNT LIBRARY -
TU1-23
TU1-22
TU1-21
TU1-19
TU1-29
TU1-31
TU1-33
TU1-32
TU1-35
TU1-34TU1-37
TU1-38
TU1-39TU1-40
TU1-41
TU1-42
TU1-43
TU1-36
TU1-24
TU1-25
TU1-28
TU1-27
TU1-26
TU1-44
T
TU1-53
T
T
T
T
T
T
T
T
T
T
TTU1-55
T
T
T
ON ROOF
EXISTING EF-2
EXISTING
EXISTING
EXISTING
EXISTING
EXISTING
EXISTING
EXISTING
EXISTING
EXISTING
EXISTING
EXISTING
EXISTING
EXISTING
EXISTINGEXISTING
EXISTING EXISTING
EXISTING
EXISTING
EXISTING
EXISTING EXISTING EXISTING EXISTING
EXISTING
TU1-30
EXISTING
TU1-20
EXISTING
EXISTING FIN TUBE
EXISTING FIN TUBE
PANEL "C"
PANEL "D"
N
NOTES:(THIS SHEET ONLY)
VALVE ACTUATOR WITH NEW VALVE ACTUATOR.
REPLACE EXISTING TERMINAL UNIT CONTROLLER WITH NEW CONTROLLER. REPLACE EXISTING HW CONTROL
22222
T1
GENERAL NOTES:(THIS SHEET ONLY)
A
B
VERIFY ITEMS TO BE DEMOLISHED.
ALL CONDITIONS FOR NEW WORK MAY NOT BE SHOWN. SURVEY EXISTING CONDITIONS TO
MATCH EXISTING IF DAMAGED DURING CONSTRUCTION.
FINISHED SPACES. REPAIR/REPLACE ANY CEILING TILES, CEILING GRIDS, OR FIXTURES TO
REMOVE EXISTING CEILING TILES WHERE SCOPE OF WORK IS PERFORMED ABOVE
MHL202
FILE PATH:
SHEET NUMBER:
316 CORPORATE PARKWAY
NBP Engineers, Inc.
MACON, GEORGIA 31210
NBP
ENGINEERS
478-745-1691 www.nbpengineers.com
No. REVISIONS/SUBMISSIONS DATE
DRAWN:
CHECKED:
DESIGNED:
DATE:
PROJECT NUMBER:
P R
O J E
C T
T
IT
L E
SHEET TITLE:
CONSULTANTS
THIS DRAWING IS THE PROPERTY OF THE
ENGINEER AND MAY NOT BE REPRODUCED
OR USED IN WHOLE OR IN PART
WITHOUT HIS WRITTEN PERMISSION. IT IS
TO BE USED FOR THE PROJECT
SPECIFICALLY IDENTIFIED HEREIN AND TO
BE RETURNED UPON REQUEST.
P:\24012\24012mhl203.dgn
AS SHOWN
WSH
LTF
WSH
24012
08.13.24
P:\24012\24012mhl203.dgn
DATE PLOTTED
DGN FILE
13-AUG-2024
F o rt V a ll e y
G e o rg ia
COA Expiration: 6.30.2026
COA#PEF000774
NBP Engineers, Inc.
F V S
U P ro je c t
N o F
V S
U B
A S -9
T
M u lt i- B u il d in g s A u to m a ti o n S y s te m s P ro je c t
F o rt V a ll e y S ta te U n iv e rs it y
1 2 3 4 5 6 7 8
DN
DN
4.5
F
E
D
C
B
A
JAN.
STOR.
STUDY LOUNGE
COPY
MAIN READING ROOM
SEMINAR
SEMINAR
G.S.
MEN,S TOILET
WOMEN,S TOILET
G.S.
G.S.
G.S.
G.S.
G.S.
G.S.
G.S.
G.S.
G.S.
G.S.
GROUP STUDIES
HALL
ALCOVE
# 2
STAIR
# 2
ELEV.
# 1
STAIR
# 1
ELEV.
TYPING
SCALE:
= 1'-0
8 0 4 8 16
HUNT LIBRARY - THIRD FLOOR PLAN - HVAC
TU1-45
TU1-46
TU1-50
TU1-57
TU1-49
TU1-48
T
T
T
T
T
T
T
T T T
T
T T T
T
T
EF-9
MAIN READING ROOM
GROUP STUDIES
TU1-47
EF-4 ON ROOF
EXISTING FAN
EF-3 ON ROOF
EXISTING FAN
EF-2 ON ROOF
EXISTING FAN
EF-1 ON ROOF
EXISTING FAN
EXISTING FIN TUBE
EXISTING FIN TUBE
EXISTING
EXISTING
EXISTING
EXISTING
EXISTING
EXISTING
EXISTING
EXISTING
PANEL "HB"
PANEL "B"
PANEL "A"
PANEL "HA"
N
HVAC
THIRD FLOOR PLAN -
HUNT LIBRARY -
MHL203
NOTES:(THIS SHEET ONLY)
VALVE ACTUATOR WITH NEW VALVE ACTUATOR.
REPLACE EXISTING TERMINAL UNIT CONTROLLER WITH NEW CONTROLLER. REPLACE EXISTING HW CONTROL
T
TT
T
GENERAL NOTES:(THIS SHEET ONLY)
A
B
VERIFY ITEMS TO BE DEMOLISHED.
ALL CONDITIONS FOR NEW WORK MAY NOT BE SHOWN. SURVEY EXISTING CONDITIONS TO
MATCH EXISTING IF DAMAGED DURING CONSTRUCTION.
FINISHED SPACES. REPAIR/REPLACE ANY CEILING TILES, CEILING GRIDS, OR FIXTURES TO
REMOVE EXISTING CEILING TILES WHERE SCOPE OF WORK IS PERFORMED ABOVE
FILE PATH:
SHEET NUMBER:
316 CORPORATE PARKWAY
NBP Engineers, Inc.
MACON, GEORGIA 31210
NBP
ENGINEERS
478-745-1691 www.nbpengineers.com
No. REVISIONS/SUBMISSIONS DATE
DRAWN:
CHECKED:
DESIGNED:
DATE:
PROJECT NUMBER:
P R
O J E
C T
T
IT
L E
SHEET TITLE:
CONSULTANTS
THIS DRAWING IS THE PROPERTY OF THE
ENGINEER AND MAY NOT BE REPRODUCED
OR USED IN WHOLE OR IN PART
WITHOUT HIS WRITTEN PERMISSION. IT IS
TO BE USED FOR THE PROJECT
SPECIFICALLY IDENTIFIED HEREIN AND TO
BE RETURNED UPON REQUEST.
P:\24012\24012mhl401.dgn
AS SHOWN
WSH
LTF
WSH
24012
08.13.24
P:\24012\24012mhl401.dgn
DATE PLOTTED
DGN FILE
13-AUG-2024
F o rt V a ll e y
G e o rg ia
COA Expiration: 6.30.2026
COA#PEF000774
NBP Engineers, Inc.
F V S
U P ro je c t
N o F
V S
U B
A S -9
T
M u lt i- B u il d in g s A u to m a ti o n S y s te m s P ro je c t
F o rt V a ll e y S ta te U n iv e rs it y
EXISTING TO REMAIN
DEMOLITION
NEW WORK
POINT OF CONNECTION
LINE LEGEND
NOT TO SCALE
TT
TT
CP-1
CHR CHR
CHS
C
H S
C H
R
SUCTION DIFFUSER
1" TO DOMESTIC WATER
SET 80#
RELIEF VALVE
CHEMICAL FEED TANK
AAV
AIR PURGER
FULL SIZE
EXTERIOR
INTERIOR MECH. ROOM
CHR-1
1"
CP-1
6"
6"
6"
6"
VALVE
3/4" DRAIN
6"
EQUIPMENT
TO AIR HANDLING
STATION
MAKE-UP WATER
ACP
DDC PANEL
INPUT/OUTPUT
SUMMARIES
OUTPUTS INPUTS SOFTWARE
DIGITAL ANALOG ANALOG ALARM DDCDIGITAL ENERGY MGMT. LOGS
S Y
S T
A P
P L
A Y
S T
A R
T
S T
O P
E N
A B
L E
D
IS
A B
L E
O P
E N
C L
O S
E
S T
A R
T
S T
K E
U P
S E
T P
O
J
U S
T
D
N T
R O
L
D
IF
F E
R E
N T
IA
L
P
R E S
S U
R E
P R
E S
S U
R E
S
W
IT
C H
A U
X
IL
IA
N T
A C
T
A L
A
N T
A C
T
T E
M P
E R
A T
U R
E
H
IG
H
L
IT
R
T A
L
IZ
A T
IO
N
P R
O P
O R
T
IO
N A
L
P R
O P
IN
T E
G R
A L
T
IM
E
S
C H
E D
U L
E
S
S
O P
T
IM
A R
T
S T
O P
D A
Y
N
IG
T B
A C
K
D E
M A
IT
C Y
C L
E
R E S
T
IM
IZ
A T
IO
N
E C
O N
O M
IZ
E R
N O
T E S
C U
R R
E
L A
Y
S P
E E
D
IN
D
IC
A T
IO
N
S P
E
N T
R O
L
P O
S
IT
IO
N
IN
D
IC
A T
IO
N
O P
E N
C L
O S
S
IT
IO
N
P A
D D
L E
S
W
IT
C H
O P
E R
A T
A T
U S
D
IF
F
P
R E S
S U
R E
P R
E S
S U
R E
S T
A T
U S
K W
H
T R
E
G
W A
T
O W
G A
L
F A
IL
U
D E (S
T E S
A
N D
1. FAILURE MODES:
2. WHERE FAILURE MODE IS INDICATED, THE INDICATED POSITION SHALL OCCUR ON INTERRUPTION OF ELECTRIC POWER TO THE DDC PANEL
L - LAST COMMAND
O - OPEN OR ON
C - CLOSE OR OFF
NOTES:
C
C
TAG
CHR-1
TT-1
TT-2
EM-1
POINT DESCRIPTION
CHILLER
ELECTRIC METER - MAIN
BUILDING UTILITY MONITORING
A1
DO DI
PURGE VALVE
A1
FM-DW
FM-GAS GAS METER
DW METER
G
O W
C C
F
HVAC
FLOW DIAGRAM -
CHILLED WATER
HUNT LIBRARY -
HUNT LIBRARY - CHILLED WATER FLOW DIAGRAM - HVAC
MHL401
20 PSIG INITIAL FILL PRESSUREVOLUME.
DIAPHRAM EXPANSION TANK.
EXISTING
EXISTING
EXISTING
EXISTING
EXISTING
NEW
NEW
EXISTING
EXISTING
EXISTING
EQUIPMENT
TO AIR HANDLING
CP-1 CHILLER PUMP
CHW SUPPLY (SYSTEM) (NEW)
CHW RETURN (SYSTEM) (NEW)
CHILLER SYSTEM
HUNT LIBRARY
FILE PATH:
SHEET NUMBER:
316 CORPORATE PARKWAY
NBP Engineers, Inc.
MACON, GEORGIA 31210
NBP
ENGINEERS
478-745-1691 www.nbpengineers.com
No. REVISIONS/SUBMISSIONS DATE
DRAWN:
CHECKED:
DESIGNED:
DATE:
PROJECT NUMBER:
P R
O J E
C T
T
IT
L E
SHEET TITLE:
CONSULTANTS
THIS DRAWING IS THE PROPERTY OF THE
ENGINEER AND MAY NOT BE REPRODUCED
OR USED IN WHOLE OR IN PART
WITHOUT HIS WRITTEN PERMISSION. IT IS
TO BE USED FOR THE PROJECT
SPECIFICALLY IDENTIFIED HEREIN AND TO
BE RETURNED UPON REQUEST.
P:\24012\24012mhl402.dgn
AS SHOWN
WSH
LTF
WSH
24012
08.13.24
P:\24012\24012mhl402.dgn
DATE PLOTTED
DGN FILE
13-AUG-2024
F o rt V a ll e y
G e o rg ia
COA Expiration: 6.30.2026
COA#PEF000774
NBP Engineers, Inc.
F V S
U P ro je c t
N o F
V S
U B
A S -9
T
M u lt i- B u il d in g s A u to m a ti o n S y s te m s P ro je c t
F o rt V a ll e y S ta te U n iv e rs it y
EXISTING TO REMAIN
DEMOLITION
NEW WORK
POINT OF CONNECTION
LINE LEGEND
NOT TO SCALE
HVAC
FLOW DIAGRAM -
HEATING WATER
HUNT LIBRARY -
HUNT LIBRARY - HEATING WATER FLOW DIAGRAM - HVAC
O
S Y
S T
A P
P L
A Y
S T
A R
T
S T
O P
E N
A B
L E
D
IS
A B
L E
O P
E N
C L
O S
E
S T
A R
T
S T
K E
U P
S E
T P
O
J
U S
T
D
N T
R O
L
D
IF
F E
R E
N T
IA
L
P
R E S
S U
R E
P R
E S
S U
R E
S
W
IT
C H
A U
X
IL
IA
N T
A C
T
A L
A
N T
A C
T
T E
M P
E R
A T
U R
E
H
IG
H
L
IT
R
T A
L
IZ
A T
IO
N
P R
O P
O R
T
IO
N A
L
P R
O P
IN
T E
G R
A L
T
IM
E
S
C H
E D
U L
E
S
S
O P
T
IM
A R
T
S T
O P
D A
Y
N
IG
T B
A C
K
D E
M A
IT
C Y
C L
E
R E S
T
IM
IZ
A T
IO
N
E C
O N
O M
IZ
E R
C U
R R
E
L A
Y
S P
E E
D
IN
D
IC
A T
IO
N
S P
E
N T
R O
L
P O
S
IT
IO
N
IN
D
IC
A T
IO
N
O P
E R
A T
A T
U S
D
IF
F
P
R E S
S U
R E
K W
P R
E S
S U
R E
W A
T
O W
S T
E
O W
S T
A T
U S
D R
IV
E
S
T A
T U
S
T R
E
G
F A
IL
U
D E (S
T E S
A
N D
N O
T E S
SOFTWAREINPUTSOUTPUTS
ANALOGDIGITAL DIGITAL ANALOG ALARM DDC ENERGY MGMT. LOGS
POINT DESCRIPTION
BOILERBLR-1
TAG
BHP-1
TT-1
TT-2
TT-3
TT-4
HWR - (SYSTEM)
HWS - (SYSTEM)
LOW WATER LEVEL
BLR-1 PUMP
HP-1 HEATING SYSTEM PUMP-VFD CONTROL
HWR - BLR LOOP
HWS - BLR-1 LOOP
DP-1 DIFFERENTIAL PRESSURE SENSOR-BUILDING LOOP
1. FAILURE MODES:
2. WHERE FAILURE MODE IS INDICATED, THE INDICATED POSITION SHALL OCCUR ON INTERRUPTION OF
ELECTRIC POWER TO THE DDC PANEL.
L - LAST COMMAND
O - OPEN OR ON
C - CLOSE OR OFF
DDC PANEL
ACP
INPUT/OUTPUT
SUMMARIES
NOTES:
MAKE-UP WATER STATION
1"C.W.
FILL
3" HWS
A.A.V.
TT
BOILER
BLR-1
TO HEATING
EQUIPMENT COILS
DRAIN WITH HOSE
END CONNECTION
(TYP.)
CHEMICAL FEED TANK
HP-1
TT
A0
BP-1
TT
GAS
ET
BALANCING FLOW METER
1"
AI
D0 D1
HP-1
3"HWS
TT
3" HWR
FLOW METER
BALANCING
D0 D1
TO HEATING
EQUIPMENT COILS
D0 A0 D1
BHP-1
1"
3"
3"
AI
AI
AIR SEPARATOR
TANGENTIAL
PURGE VALVE
EXPANSION TANK, 15 PSI FILL PRESSURE
MHL402
NEW
NEW
NEW
NEW
EXISTING
EXISTING
EXISTING
EXISTING
EXISTING
EXISTING
EXISTING
EXISTING
EXISTING
1"
BOILER PLANT SYSTEM
FILE PATH:
SHEET NUMBER:
316 CORPORATE PARKWAY
NBP Engineers, Inc.
MACON, GEORGIA 31210
NBP
ENGINEERS
478-745-1691 www.nbpengineers.com
No. REVISIONS/SUBMISSIONS DATE
DRAWN:
CHECKED:
DESIGNED:
DATE:
PROJECT NUMBER:
P R
O J E
C T
T
IT
L E
SHEET TITLE:
CONSULTANTS
THIS DRAWING IS THE PROPERTY OF THE
ENGINEER AND MAY NOT BE REPRODUCED
OR USED IN WHOLE OR IN PART
WITHOUT HIS WRITTEN PERMISSION. IT IS
TO BE USED FOR THE PROJECT
SPECIFICALLY IDENTIFIED HEREIN AND TO
BE RETURNED UPON REQUEST.
P:\24012\24012mhl403.dgn
AS SHOWN
WSH
LTF
WSH
24012
08.13.24
P:\24012\24012mhl403.dgn
DATE PLOTTED
DGN FILE
13-AUG-2024
F o rt V a ll e y
G e o rg ia
COA Expiration: 6.30.2026
COA#PEF000774
NBP Engineers, Inc.
F V S
U P ro je c t
N o F
V S
U B
A S -9
T
M u lt i- B u il d in g s A u to m a ti o n S y s te m s P ro je c t
F o rt V a ll e y S ta te U n iv e rs it y
NOT TO SCALE
DDC PANELS
INPUT/OUTPUT
SUMMARIES
ACP
S Y
S T
A P
P L
A Y
S T
A R
T
S T
O P
E N
A B
L E
D
IS
A B
L E
O P
E N
C L
O S
E
S T
A R
T
S T
K E
U P
S E
T P
O
J
U S
T
D
N T
R O
L
D
IF
F E
R E
N T
IA
L
P
R E S
S U
R E
P R
E S
S U
R E
S
W
IT
C H
A U
X
IL
IA
N T
A C
T
A L
A
N T
A C
T
T E
M P
E R
A T
U R
E
R E
L A
T
M
ID
IT
Y
P R
E S
S U
R E
H
IG
H
L
IT
R
T A
L
IZ
A T
IO
N
P R
O P
O R
T
IO
N A
L
P R
O P
IN
T E
G R
A L
T
IM
E
S
C H
E D
U L
E
S
S
O P
T
IM
A R
T
S T
O P
D A
Y
N
IG
T B
A C
K
D E
M A
IT
C Y
C L
E
R E S
T
IM
IZ
A T
IO
N
E C
O N
O M
IZ
E R
F A
IL
U
D E (S
T E S
A
N D
N O
T E S
DIGITAL ANALOG ANALOG ALARM DDC ENERGY MGMT.DIGITAL
C U
R R
E
L A
Y
D R
IV
E
S
T A
T U
S
S P
E E
D
IN
D
IC
A T
IO
N
S P
E
N T
R O
L
E
IT
C H
C O
O W
C A
L C
U L
A T
IN
T
P O
S
IT
IO
N
IN
D
IC
A T
IO
N
O P
E N
C L
O S
S
IT
IO
N
S T
A T
U S
T R
E
G
LOGS
PHC CONTROL VALVE
R.A. TEMP.
PHC-L.A.T.
R.A.-RH
PRIMARY AIR FLOW
AIR TERMINAL UNITS (TU/FP)
S.A. DAMPER ACTUATOR
HC VALVE
PERCENTAGE DESIGN FLOW-HEATING
PERCENTAGE DESIGN FLOW-COOLING
TAG
OA 1
AFMS 1
FAR
TT 1
TT 2
TT 3
TT 4
SPS H
SPS 1
TUC-XX
TUC-XX
TUC-XX
ZONE-SPACE TEMP.
S.A. TEMP. TO ZONESAT
LL
HT
M.A. TEMP.
CC-L.A.T.
S.A.-SPS
S.A.-TEMP.
L.L.-TEMP.
T-XX
CC CONTROL VALVE
TT 5
VLV 1
VLV 2
HIGH LIMIT SPS
BUILDING PRESSUREDP 1
AHU-1
VFD 1, 2
O
C
L
C
L
C
NOTES:
1. FAILURE MODES:
2. WHERE FAILURE MODE IS INDICATED, THE INDICATED POSITION SHALL OCCUR ON INTERRUPTION OF
ELECTRIC POWER TO THE DDC PANEL.
L - LAST COMMAND
O - OPEN OR ON
C - CLOSE OR OFF
SOFTWAREINPUTSOUTPUTS
TT
FAR
DP
SAF
VFD
FAR
VLV
TT
LL
TT
TT
VLV
1 2
SPS
AI
FIL PHC
TUC
T-X
TUC
T-X
SAT
TU-X
SAT
TU-X
SPS
H
AID0 A0 D1
AH-1 AH-1 AH-1
CC
R
AHU
EXTERIOR
WALL
H W
R
H W
S
COND.
ZONE
H W
R
H W
S
COND.
ZONE
CHS
CHRHWR
HWS
MCP
TU-X
TU-X
T
T
AI
NEW
AI
NEW
AI AO
NEW
AI
NEW
NEW
AI
AI
NEW
AI AO
DI
NEW
DI
NEW
SD
SASA FAN
AI
NEW
DI
NEW
AI
NEW
AI
NEW
AI AO
NEW ACTUATOR
AI AO
NEW ACTUATOR
EXISTING VFD
CONNECT TO
VFD
TT
AI
HT
AI
AI AO
OA
NEW ACTUATOR
AI
NEW
AFMS
LOUVER
OA INTAKE
EXISTING
EXISTING
EXISTING
EXISTING
MHL403
HVAC
AHU FLOW DIAGRAM -
HUNT LIBRARY -
SA FAN
VFD
FAR
AID0 A0 D1
R
EXISTING VFD
CONNECT TO
VFD
RAF
HUNT LIBRARY - AHU FLOW DIAGRAM - HVAC
AHU VAV SYSTEM
HUNT LIBRARY
RA/SA FAN-VFD
MIN. OA AFMS
MIN. OA DAMPER
F.A. RELAY
S T
A P
P L
A Y
S T
A R
T
S T
O P
E N
A B
L E
D
IS
A B
L E
O P
E N
C L
O S
E
S T
A R
T
S T
K E
U P
S E
T P
O
J
U S
T
D
N T
R O
L
D
IF
F E
R E
N T
IA
L
P
R E S
S U
R E
P R
E S
S U
R E
S
W
IT
C H
A U
X
IL
IA
N T
A C
T
A L
A
N T
A C
T
T E
M P
E R
A T
U R
E
R E
L A
T
M
ID
IT
Y
P R
E S
S U
R E
S T
A T
U S
IN
T E
R L
O C
K
H
IG
H
L
IT
R
T A
L
IZ
A T
IO
N
P R
O P
O R
T
IO
N A
L
P R
O P
IN
T E
G R
A L
T
IM
E
S
C H
E D
U L
E
S
S
O P
T
IM
A R
T
S T
O P
D A
Y
N
IG
T B
A C
K
D E
M A
IT
C Y
C L
E
R E S
T
IM
IZ
A T
IO
N
E C
O N
O M
IZ
E R
F A
IL
U
D E (S
T E S
A
N D
N O
T E S
OUTPUTS INPUTS SOFTWARE
DDC PANELS
INPUT/OUTPUT
SUMMARIES
DIGITAL ANALOG ANALOG ALARM DDC ENERGY MGMT.DIGITAL
C U
R R
E
L A
Y
D R
IV
E
S
T A
T U
S
S P
E E
D
IN
D
IC
A T
IO
N
S P
E
N T
R O
L
E
IT
C H
C O
O W
S.A. TEMP.
C
NOTES:
1. FAILURE MODES:
2. WHERE FAILURE MODE IS INDICATED, THE INDICATED POSITION SHALL OCCUR ON INTERRUPTION OF
ELECTRIC POWER TO THE DDC PANEL.
L - LAST COMMAND
C A
L C
U L
A T
IN
T
O - OPEN OR ON
C - CLOSE OR OFF
TAG
FAR
TT 1
F.A. RELAY
P O
S
IT
IO
N
IN
D
IC
A T
IO
N
O P
E N
C L
O S
S
IT
IO
N
CHR
CHS
T
R
FC FC
ACP
T ZONE-SPACE TEMP.
T R
E
G S
HWR
HWS
VLV
FC
T
1 2
SAF SUPPLY FAN C
HC
FAN COIL-TYPICAL
A1
FAN COIL - FC
VLV 1 HC CONTROL VALVE
VLV 2 CC CONTROL VALVE
C
MVD
A1
NOT TO SCALE
HUNT LIBRARY - FAN COIL UNITS FLOW DIAGRAM - HVAC
OA
OA FROM ERU-1
RA SA
SD
FAR
SAF
ZONE
CONDITIONED
TUC
TTFAR
CCFIL
VLV
A0 A1 A0 A1
NEW ACTUATOR
NEW ACTUATOR
COMMON MIXING PLENUM
EXISTING
EXISTING
SA FAN
EXISTING
FILE PATH:
SHEET NUMBER:
316 CORPORATE PARKWAY
NBP Engineers, Inc.
MACON, GEORGIA 31210
NBP
ENGINEERS
478-745-1691 www.nbpengineers.com
No. REVISIONS/SUBMISSIONS DATE
DRAWN:
CHECKED:
DESIGNED:
DATE:
PROJECT NUMBER:
P R
O J E
C T
T
IT
L E
SHEET TITLE:
CONSULTANTS
THIS DRAWING IS THE PROPERTY OF THE
ENGINEER AND MAY NOT BE REPRODUCED
OR USED IN WHOLE OR IN PART
WITHOUT HIS WRITTEN PERMISSION. IT IS
TO BE USED FOR THE PROJECT
SPECIFICALLY IDENTIFIED HEREIN AND TO
BE RETURNED UPON REQUEST.
P:\24012\24012mpat200.dgn
AS SHOWN
WSH
LTF
WSH
24012
08.13.24
P:\24012\24012mpat200.dgn
DATE PLOTTED
DGN FILE
13-AUG-2024
F o rt V a ll e y
G e o rg ia
COA Expiration: 6.30.2026
COA#PEF000774
NBP Engineers, Inc.
F V S
U P ro je c t
N o F
V S
U B
A S -9
T
M u lt i- B u il d in g s A u to m a ti o n S y s te m s P ro je c t
F o rt V a ll e y S ta te U n iv e rs it y
RAMP
STORAGE No. 1
STORAGE No. 2
PASSAGE
SERVICE
ROOM
MECHANICAL
BOILER ROOM
No. 3
STORAGE
ROOM
MACHINE
ELEV
SCALE:
= 1'-0
8 0 4 8 16
N
FLOOR PLAN - HVAC
BASEMENT
PATTON HALL -
PATTON HALL - BASEMENT FLOOR PLAN - HVAC
AHU-1
ACP-1
CP-1
UH-1
EXISTING
PUMP TO REMAIN
EXISTING SUMP
FILTER
HC
AX
CC
FAN
EXPANSION TANK
EXISTING CHW
HOUSEKEEPING PAD
EXISTING
EXPANSION TANK
EXISTING HEATING
T.E. 6'-0"
STACKED AT WALL;
EXISTING HP-1 & HP-2
STARTER-HP-1
EXISTING
STARTER-HP-1
EXISTING
CHEMICAL FEED TANK
EXISTING HW
EXISTING
HOUSEKEEPING PAD
EXISTING
STARTER-CP-1
EXISTING
CHEMICAL FEED TANK
EXISTING CHW
EXISTING
HOUSEKEEPING PAD
EXISTING
CH-1
EXISTING
TRANSFORMER
EXISTING
JUNCTION BOX
EXISTING ELEC.
EXISTING
STARTER-AHU-1
MPA200
NOTES:(THIS SHEET ONLY)
GENERAL NOTES:(THIS SHEET ONLY)
A
VERIFY ITEMS TO BE DEMOLISHED.
ALL CONDITIONS FOR NEW WORK MAY NOT BE SHOWN. SURVEY EXISTING CONDITIONS TO
REMOVE EXISTING CONTROLLERS AND PROVIDE NEW CONTROLLERS.
FILE PATH:
SHEET NUMBER:
316 CORPORATE PARKWAY
NBP Engineers, Inc.
MACON, GEORGIA 31210
NBP
ENGINEERS
478-745-1691 www.nbpengineers.com
No. REVISIONS/SUBMISSIONS DATE
DRAWN:
CHECKED:
DESIGNED:
DATE:
PROJECT NUMBER:
P R
O J E
C T
T
IT
L E
SHEET TITLE:
CONSULTANTS
THIS DRAWING IS THE PROPERTY OF THE
ENGINEER AND MAY NOT BE REPRODUCED
OR USED IN WHOLE OR IN PART
WITHOUT HIS WRITTEN PERMISSION. IT IS
TO BE USED FOR THE PROJECT
SPECIFICALLY IDENTIFIED HEREIN AND TO
BE RETURNED UPON REQUEST.
P:\24012\24012mpat201.dgn
AS SHOWN
WSH
LTF
WSH
24012
08.13.24
P:\24012\24012mpat201.dgn
DATE PLOTTED
DGN FILE
13-AUG-2024
F o rt V a ll e y
G e o rg ia
COA Expiration: 6.30.2026
COA#PEF000774
NBP Engineers, Inc.
F V S
U P ro je c t
N o F
V S
U B
A S -9
T
M u lt i- B u il d in g s A u to m a ti o n S y s te m s P ro je c t
F o rt V a ll e y S ta te U n iv e rs it y
CORRIDOR
LOBBY
RECEPTION
DEPARTMENT
ROOM
BAND & ORCHESTRA
RM. No.5
PRACTICE
RM. No.4
PRACTICE
INSTRUMENT STORAGE
PASSAGE No. 4
P A
S S
A o
PASSAGE No. 6
PORCH
No. 4
PASSAGE
NO.1
TOILETS
WOMEN'S
NO.1
TOILETS
MEN'S
LOBBY
TOILETS
TEACHERS
WOMEN'S
TOILETS
TEACHERS
MEN'S
CLOS.
JAN.
WORK RM
EXIST. RAMP
STORAGE
UNIFORM
No. 2
STAIR
ELEV.
VESTIBULE
ROOM
CHOIR
CLASSROOM
STUDIO
DEPT HEAD/VOICE
INSTRUMENT
STORAGE
CONFERENCE
ROOM
VESTIBULE
KITCHENETTE
1 1 1
PATTON HALL - FIRST FLOOR PLAN - HVAC
HVAC
FIRST FLOOR PLAN -
PATTON HALL -
SCALE:
= 1'-0
8 0 4 8 16
N
WH
ENTRANCE
FIBER OPTIC
T
T
T
T
T
TU1-10
EF1-1
TU1-1
TU1-1 1
T
T
T
T
TU1-3
TU1-2
TU1-5
TU1-4
TU1-9TU1-8TU1-7
TU1-6
B1 B
EXISTING
EXISTING
EXISTING
EXISTING
EXISTING
EXISTING EXISTING EXISTING
EXISTING
EXISTING
EXISTING
EXISTING
T
MPA201
NOTES:(THIS SHEET ONLY)
VALVE ACTUATOR WITH NEW VALVE ACTUATOR.
REPLACE EXISTING…
This is the start of the file's text. The full file is on GovTribe.
File details come from the government source that posted it. Updated .