This document appears to be a condition and priority table for a 2016 asbestos reinspection at the Waco VA Medical Center. It provides a detailed assessment of the current condition and potential for disturbance of asbestos-containing materials (ACM) in Building 17, including the basement and first floor. The table uses a numerical rating system to categorize the condition and removal priority of the ACM, with 1 indicating poor condition or high priority, and 10 indicating good condition or low priority.
The related federal contract opportunity is solicitation number 36C25724B0015 for the abatement and clean-up of Buildings 14 and 17 at the Doris Miller VA Medical Center in Waco, Texas. This is a solicitation issued by the Department of Veterans Affairs Veterans Health Administration Veterans Integrated Service Network 17.
View the file
Other files
Show all 27
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
HMA
| Homogeneous Area No. | Bldg | Floor | Material Description | Friable Yes/No | Accessibility Yes/No Restricted | Current Condition 1 | Potential for Disturbance 2 | Removal Priority 3 | ||
| Rating | Based On | Rating | Based On | |||||||
| Building 17 - Basement | ||||||||||
| No ACM | ||||||||||
| Building 17 - First Floor | ||||||||||
| HMA-1 | 17 | 1 | Floor Mastic | No | No | 10 | Intact | 1 | Access | 9 |
| Building - Roof | ||||||||||
| No ACM |
&L&"Times New Roman,Regular"&11 &C&"Times New Roman,Bold"&12WACO V. A. MEDICAL CENTER
2016 THREE-YEAR ASBESTOS REINSPECTION
CONDITION AND REMOVAL PRIORITY TABLE&R&"Times New Roman,Regular"&11 &CPage &P of &N
Tables
| 1 Qualitative Rankings and Quantitative (Numerical) Ratings for Current Condition | |||
| Qualitative Ranking | Numerical Rating | Description of Current Condition | |
| Good | 8, 9, 10 | Surfacing material has no visible damage or small amounts of damage; covering on thermal system insulation is intact or has small amounts of damage; miscellaneous materials intact; no visible debris or small amounts of debris. | |
| Fair | 4, 5, 6, 7 | Surfacing material has moderate but not extensive amounts of visible damage; covering on thermal system insulation is cut or torn, exposing moderate but not extensive amounts of insulation; moderate but not extensive damage to miscellaneous materials such as floor tile; moderate but not extensive amounts of visible dust and debris.. | |
| Poor | 1, 2, 3 | Extensive damage to surfacing material; covering on thermal system insulation is cut or torn extensively and insulation itself is damage; miscellaneous materials such as floor tile extensively damaged and underlying mastic exposed; extensive amounts of dust and debris. | |
| 2 Qualitative Rankings and Quantitative (Numerical) Ratings for Potential for Disturbance | |||
| Qualitative Ranking | Numerical Rating | Assessment Factors | |
| Physical Disturbance | Environmental Disturbance | ||
| Low | 1, 2, 3 | Accessibility: accessibility during normal operations |
Activities: activities that people do and how often they do them Vibration: vibration from operating machinery, HVAC equipment, and so forth
Air/Dust: air currents strong enough to dislodge loose ACM; airborne dust that can erode material
Corrosive: corrosive atmosphere or liquids that can erode the covering or matrix
Water Damage: water damage from leaking roof, pipe or other source
| Medium | 4, 5, 6, 7 | |
| High | 8, 9, 10 | |
| 3 Qualitative Rankings and Quantitative (Numerical) Ratings for Removal Priority | ||
| Qualitative Ranking | Numerical Rating | Description of Current Condition |
| High | 1, 2, 3 | Address short-term |
| Medium | 4, 5, 6, 7 | Address with on-going maintenance procedures |
| Low | 8, 9, 10 | Maintain in good condition |
&L&"Times New Roman,Regular"&11 &R&"Times New Roman,Regular"&11