This document is a solicitation from the Office of the Federal Public Defender, District of Kansas, requesting quotations for the procurement of furniture for their existing office space in Kansas City, Kansas. The solicitation includes general project requirements such as delivery, installation, debris removal, and insurance coverage. Offerors are required to provide an itemized price quotation, including per item pricing, total cost, manufacturer specifications, and all associated freight, delivery, and installation costs. The award will be made to the lowest priced offeror that meets the technical requirements, with a desired delivery and installation completion date of Tuesday, September 6, 2024. All offers must be received by 5:00 P.M. CST on Thursday, July 18, 2024. The contracting agency is the Administrative Office of the U.S. Courts.
View the file
Other files
| File | Type | Posted |
|---|---|---|
| KCK.2024.06 RFQ_SOW.pdf | ||
| KCK.2024.06 RFQ_VendorInfoSheet.pdf | ||
| KCK.2024.06 Furniture_List.pdf |
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
1. DO NOT SCALE DRAWINGS. USE FIGURED DIMENSIONS ONLY, VERIFY
ALL DIMENSION PRIOR TO START OF WORK. IN THE EVENT OF
DISCREPANCY, NOTIFY C.O.R. AND OBTAIN RESOLUTION BEFORE
PROCEEDING."
2. NOTIFY THE C.O.R. OF ANY AND ALL DISCREPANCIES BETWEEN
EXISTING CONDITIONS AND THE CONTRACT DOCUMENTS BEFORE
PROCEEDING WITH THAT PORTION OF WORK. FAILURE TO NOTIFY THE
C.O.R. WILL NOT RELIEVE THE CONTRACTOR OF RESPONSIBILITY TO
PERFORM THE WORK AS INTENDED BY THE CONTRACT DOCUMENTS.
CONTRACTOR SHALL BE RESPONSIBLE FOR ALL WORK ARISING FROM
SUCH FAILURE TO COORDINATE DISCREPANCIES TO THE
SATISFACTION OF THE C.O.R.."
3. WHERE EXISTING CONSTRUCTION AND GRIDS ARE INDICATED,
CONTRACTOR SHALL VERIFY EXISTING DIMENSIONED GRIDS PRIOR TO
PERFORMING LAYOUT WORK REQUIRED FOR INSTALLATION OF NEW
WORK."
4. VERIFY EXISTING DIMENSIONS, CONDITIONS AND CLEARANCES PRIOR
TO THE SUBMITTAL OF SHOP DRAWINGS"
5. ALL SLEEVES, OPENINGS, ETC. FOR CONDUIT, PIPES, DUCTS, ETC.
(OUTSIDE OF RATED CHASES) THROUGH FLOOR SLABS AND RATED
PARTITIONS ARE TO BE FIRE SEALED IN ACCORDANCE WITH FIRE
RATED ASSEMBLY DESIGNS, APPLICABLE CODES AND FIRE MARSHAL'S
REQUIREMENTS."
6. PROVIDE A MINIMUM OF 3/4"" FIRE-RETARDANT TREATED WOOD
BLOCKING OR 18 GA. MINIMUM STEEL PLATE BLOCKING AS REQUIRED
WITHIN STEEL STUD FRAMED PARTITIONS FOR SECURE AND PROPER
ATTACHMENT OF NEW WORK, INCLUDING BUT NOT LIMITED TO A/V
EQUIPMENT, MILLWORK, VISUAL DISPLAY SURFACES, SIGNAGE, AND
FURNISHINGS WHERE INDICATED ON PLANS."
7. WHERE WORK OCCURS IN AREAS WITH EXISTING FINISHES TO REMAIN,
REFINISH DISTURBED AREAS TO MATCH EXISTING FINISHES AND
MATERIALS UNLESS NOTED OR DIRECTED OTHERWISE."
8. CONTRACTOR SHALL BE RESPONSIBLE FOR VERIFYING ALL
DIMENSIONS, ELEVATIONS, AND DETAIL SHOWN ON THE DRAWINGS.
ANY DISCREPANCIES WHICH WILL PREVENT THE ACCOMPLISHMENT OF
INTENT SHOWN ON DRAWINGS SHALL BE BROUGHT TO THE IMMEDIATE
ATTENTION OF THE C.O.R.. INDICATED CONDITIONS ARE NOT
INTENDED AS REPRESENTATIONS OR WARRANTIES OF ACCURACY. IT
IS EXPRESSLY UNDERSTOOD THAT THE GOVERNMENT WILL NOT BE
RESPONSIBLE FOR INTERPRETATIONS OR CONCLUSIONS DRAWN BY
THE CONTRACTOR."
9. WHERE CONDUIT, PIPES, DUCTS, ETC. ARE INDICATED TO BE
INSTALLED IN EXISTING WALLS AND NO FURRING IS SHOWN, THE
WALLS SHALL BE NEATLY CHASED, CONDUITS, ETC. INSTALLED, AND
WALLS PATCHED TO MATCH EXISTING. IN AREAS OF NEW PARTITIONS
WHERE CONDUITS, DUCTS, PIPING, ETC, PASS THROUGH FINISHED
SPACES, ROUTE WITHIN PARTITION CONSTRUCTION."
10. PROTECT AND PRESERVE ALL EXISTING ITEMS TO REMAIN AND REPAIR
AND/OR REPLACE ANY ITEMS DAMAGED DURING THE COURSE OF THE
WORK TO THE SATISFACTION AND APPROVAL OF THE C.O.R. WITHOUT
ADDITIONAL COST TO THE GOVERNMENT."
11. (## ## ##) INDICATES REFERENCED SPECIFICATIONS FOR PRODUCTS
AND MATERIALS SHOWN ON THE DRAWINGS AND SPECIFIED IN THE
PROJECT MANUAL."
GENERAL NOTES - FLOOR PLAN
NEW CONSTRUCTION
EXISTING CONSTRUCTION
X
ROOM NAME
DOOR INDICATION TAG
PARTITION TYPE
WINDOW TYPES
PLAN KEYNOTES
SPOT ELEVATION
DRAWING REVISION
ROOM NAME AND NUMBER
CENTER LINE
MATCH LINE
FLOOR PLAN SYMBOLS
NEW GRID IDENTIFIER
EXISTING GRID IDENTIFIER
OFFICE 200A
OFFICE 200B
OFFICE 200C
OFFICE 200D
OFFICE 200E
OFFICE 200F
OFFICE 201C
S T
O R
A G
E
A
OFFICE 201E
OFFICE 201F
OFFICE 201G
OFFICE 201H
OFFICE 201N
OFFICE 201M
OFFICE 201R
SERVER 201B
STORAGE 201J
INTERVIEW/CONF. 201L
RECEPTION 201T
GALLEY / WORK RM
201K
IT / OFFICE 201D
SM. CONF. 200H
T E
L E
W O
R K
Q
EXPANDED ELEVATOR
LOBBY 207
CORRIDOR 201S
TELEWORK 201P
NO WORK IN
SHADED AREA
NO WORK IN
SHADED AREA
EX207
E X
E X
EX204
E X
EX211
E X
EX27
A
202A
E X
226A
B
A
A
A
230A
219A
E X
215A
EX232
205A
A
A
A
A
GSA 203
A B C D E
G3
G3
G3
G1
G1
G2
G2
G2
G2
G2
G2
G2
G2
G2
G2
G1
G1
G1
G1
G2
G2
G2
G2
G2
G2
COMMON AREA/
CORRIDOR 201
A2
A2
A3
A3
A4
A2
ID211
20' - 0" 40' - 0" 20' - 0" 40' - 0"
208A
SCOPE AREA B
SCOPE AREA A
G2
A2 A2
220A
A9
A9
A9
A9
A9
A10
ID211
ID211 8
2' - 8 1/4"
/2
MIN.
1' - 0"
/2
11' - 9 1/2" 11' - 9 1/2"
ALIGN
A L
IG
N
A L
IG
N
/4
STAIR 1
A13
A13
AREA OF WORK
A B C D E
1. REFER TO PARTITION TYPE SYMBOLS ON FLOOR PLANS.
2. REFER TO CODE PLAN FOR MINIMUM REQUIRED FIRE RATING IN HOURS.
3. PARTITION TYPES DO NOT INDICATE WHICH SIDE FINISH MATERIALS ARE
APPLIED. REFER TO FINISH PLAN.
4. REFER TO THE PROJECT MANUAL FOR MINIMUM GAGE STUDS, RUNNERS,
FURRING CHANNELS, MISC. ANGLES & CLIPS.
5. FIRE RATED WALLS SHALL MAINTAIN FIRE RATING AS SCHEDULED
CONTINUOUSLY TO UNDERSIDE OF SLAB OR ROOF DECK.
6. PARTITIONS ARE DIMENSIONED TO THE FACE OF THE GYPSUM/
VENEER/BACKER BOARD - NOT APPLIED FINISH MATERIAL (i.e. VENEER, CERAMIC TILE, ETC.)
7. COORDINATE THE LOCATION OF FIRE RATED PARTITIONS WITH CODE PLANS.
8. REFER TO STRUCTURAL DRAWINGS FOR DESIGN OF LOAD BEARING
PARTITIONS.
9. HOLD ALL GYPSUM BOARD 1/2"" ABOVE CONCRETE SLAB TO AVOID WICKING
ACTION.
10. CONTRACTOR TO PROVIDE FIRE RETARDANT BLOCKING IN FIRE RATED
WALLS AS NECESSARY TO MOUNT FIXTURES, RAILS, MILLWORK, AND
ACCESSORIES PER MANUFACTURER'S RECOMMENDATIONS TO MEET
APPLICABLE BUILDING CODES. WHERE MASONRY CONSTRUCTION IS
INDICATED, CONTRACTOR TO PROVIDE ANCHORS INTO MASONRY AND
GROUT CELLS FULL AS REQUIRED TO MOUNT FIXTURES AND ACCESSORIES
PER MANUFACTURER'S RECOMMENDATIONS.
11. FIRE STOPPING IS REQUIRED AT: A. ALL PENETRATIONS THROUGH FIRE AND
SMOKE RESISTIVE FLOOR AND ROOF CONSTRUCTION. B. ALL VOIDS AND
JOINTS AT TOP AND BOTTOM OF ALL FIRE AND SMOKE RESISTIVE WALLS AND
PARTITIONS. C. CONTROL AND EXPANSION JOINTS IN ALL FIRE / SMOKE
RESISTIVE WALLS AND PARTITIONS AND FIRE RESISTIVE FLOOR AND ROOF
CONSTRUCTION.
12. WHERE INTERIOR MASONRY IS TO BE EXPOSED, BULLNOSE CORNER UNITS
TO BE USED. STARTER COURSE TO BE SQUARE UNIT WITH BULLNOSE
ABOVE.
13. WHERE MASONRY CONSTRUCTION IS INDICATED, CONTRACTOR SHALL
COORDINATE LOCATION, SIZE, TYPE, AND SPACING OF ALL MASONRY
ANCHORS AND REINFORCEMENT WITH STRUCTURAL DRAWINGS.
14. WHERE GYPSUM BOARD IS INDICATED TO BE INSTALLED AT WET LOCATIONS,
INCLUDING BUT NOT LIMITED TO TOILETS AND JANITOR'S CLOSETS,
MOISTURE AND MOLD-RESISTANT GYPSUM BOARD SHALL BE PROVIDED.
GENERAL NOTES - PARTITIONS
(G1)(G1)
ONE LAYER OF 5/8" GWB ON
BOTH SIDES OF
3 5/8" 25 GAUGE MTL STUD AT
24" O.C. WITH GYP AND
INSULATION UP TO
STRUCTURE (STC 48)
(G1)
STRUCTURE ABOVE.
(G2)
ONE LAYER OF 5/8" GWB ON
BOTH SIDES OF 3 5/8" MTL STUD
WITH GYP 6" ABOVE CEILING
STEEL STUDS, 3 5/8" AT 16" O.C.
(092216)
M
IN
ACOUSTIC SEALANT ALL SIDES
TOP AND BOTTOM (079219)
BASE, RE: FINISH PLAN
FINISH CEILING. RE: RCP.
STRUCTURE ABOVE.
BASE, RE: FINISH PLAN
(G3)
ONE LAYER OF 5/8" GWB ON
BOTH SIDES OF 2 1/2" MTL STUD
WITH GYP 6" ABOVE CEILING
STEEL STUDS, 2 1/2" AT 16" O.C.
(092216)
M
IN
FINISH CEILING. RE: RCP.
STRUCTURE ABOVE.
BASE, RE: FINISH PLAN
GYPSUM BOARD, 5/8" (092900)
GYPSUM BOARD, 5/8" (092900)
GYPSUM BOARD, 5/8" (092900)
ACOUSTIC SEALANT ALL SIDES
TOP AND BOTTOM (079219)
STEEL STUDS, 3 5/8" 25 GAUGE
AT 24" O.C. (092216)
GYPSUM BOARD, 5/8" (092900)
GLASS FIBER ACOUSTICAL
BLANKET INSULATION, MATCH
CAVITY DEPTH (092900)
GLASS FIBER ACOUSTICAL
BLANKET INSULATION, MATCH
CAVITY DEPTH (092900)
GLASS FIBER ACOUSTICAL
BLANKET INSULATION, MATCH
CAVITY DEPTH (092900)
SLIP TYPE HEAD JOINT, 2 1/2"
(092216)SLIP TYPE HEAD JOINT, 3 5/8"
(092216)
SLIP TYPE HEAD JOINT, 3 5/8"
(092216)
GENERAL SERVICES ADMINISTRATION
PUBLIC BUILDING SERVICE
HEARTLAND REGION 6
2300 MAIN STREET, 7TH FLOOR
KANSAS CITY, M0 64108-2416
N
2ND FLOOR
SENSITIVE BUT UNCLASSIFIED (SBU)
PROPERTY OF THE UNITED STATES GOVERNMENT
FOR OFFICIAL USE ONLY
DO NOT REMOVE THIS NOTICE
PROPERLY DESTROY OR RETURN DOCUMENTS WHEN NO LONGER
NEEDED
2ND FLOOR
100% CONSTRUCTION DOCUMENTS
08/11/2017
FEDERAL PUBLIC DEFENDER EXPANSION
N1558030
ROBERT RUSBARSKY
ROBERT J. DOLE U.S. COURTHOUSE
500 STATE AVENUE
KANSAS CITY KS 66101
KS0094
SFS ARCHITECTURE
SMITH & BOUCHER
GS-06-P-15-GY-D-7000
WO-23
C E R T
IF
IC
A T
IO
N S
K E Y
P L A N
R E V
IS
IO
N
N O T E S
PROPERTY OF THE UNITED STATES GOVERNMENT - FOR OFFICIAL USE ONLY. Do not remove this notice. Properly destroy documents when no longer needed.
SHEET SIZE:
SHEET OF
DISCIPLINE SHEET TYPE SEQUENCE
DRAWING NO.
DRAWING TITLE
FILE NAME
CHECKED BY
DRAWN BY DATE DRAFTED:
PROJECT NO.
GSA PM
SUB. DATE
SUBMISSION
DESCRIPTION
PROJECT
TITLE
BUILDING NOs.
OTHER
BUILDING NO.
CITY/ST./ZIP
STREET
NAME
D R A W
IN
G
P R O J E C T
B U
IL
D
IN
G
SUB A/E
PRIME A/E
A/E CONTR. NO.
C O N T R A C T O R S
G R
AP
H
IC
SC
AL
E
MARK DATE DESCRIPTION
FLOOR NO.
FACILITY CODE
PROJECT
A/E W.O. NO.
24 X 36
WF, MK
KS
KS0094ZZ
/1
/2
:0 :0
P
M
A111
FLOOR PLAN AND PARTITION TYPES
N1558030-A111.DWG
1/8" = 1'-0"A111
2 FLOOR PLAN
1" = 1'-0"
TYPES - WALLS
08' 16'8'
1/8" = 1'-0"
01' 2'1'
1" = 1'-0"
LEGEND - KEYNOTES FLOOR PLAN
Key Value Keynote Text
A2 WORKSTATIONS, PROVIDED BY THE GOVERNMENT.
A3 COPIER, PROVIDED BY THE GOVERNMENT.
A4 SMOKE CURTAIN (105200)
A9 SALVAGED DOOR. RE: DEMO PLAN
A10 SALVAGED DOOR.
A13 ADJUST DOOR CLOSER. OPENING FORCE OF THE DOOR SHOULD
NOT EXCEED FIVE POUNDS MAXIMUM.
A111
OFFICE 1OFFICE 2OFFICE 3OFFICE 4OFFICE 5
RECEPTIONIST AREA
WALKWAY 6
sreynolds Highlight sreynolds Highlight sreynolds Highlight sreynolds Highlight
| Sheets |
| A111 - FLOOR PLAN AND PARTITION TYPES |
| A131 - CEILING PLAN |
| A601 - DOOR TYPES AND SCHEDULES |
| AD111 - DEMOLITION PLAN |
| AD121 - CEILING DEMOLITION PLAN |
| G001 - COVER |
| ID111 - FINISH PLAN, LEGEND, AND SCHEDULE |
| ID211 - ENLARGED PLAN, INT. ELE.& DETAILS |
File details come from the government source that posted it. Updated .