04 Plans 2024-06 Micro Park White Pine Trail.pdf

PDF 953 KB Posted

Attached to
Micro Park - White Pine Trail Location
Solicitation number
2024-12
Issued by
Washtenaw County, Burt CDP, Michigan

About this file

These are bidding plans for the City of Cadillac Micro Parks project, specifically for the White Pine Trail Location, prepared by Prein & Newhof engineering firm. The project involves constructing a micro park with approximately 100 square yards of concrete area, a 6' x 10' concrete mural wall, 70 linear feet of 12" culvert, 3 exercise stations, and 1 solar light. Bids are due by 2:00 p.m. on Tuesday, July 9, 2024, to be publicly opened at the Cadillac Municipal Complex, with contract documents available from the project engineer for a nonrefundable fee of $30.00 per mailed set of plans.

Bidders are required to submit a proposal guarantee of 5% in the form of a cashier's check, certified check, money order, or bid bond. The successful bidder must provide performance and labor/material bonds, each covering 100% of the contract price. The project is located on White Pine Trail (Sunnyside Drive) and will be constructed according to Michigan Department of Transportation 2020 Standard Specifications, with specific attention to traffic control, utility protection, and site-specific design requirements. Proposed features include bicycle racks, a bench, waste receptacle, visitor bureau sign, and a concrete wall prepared for a mural.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

N

PLANS FOR

CITY OF CADILLAC

AND SHALL BE RESPONSIBLE FOR CONSTRUCTION SIGNING AND WORK ZONE PROTECTION.

THE CONTRACTOR SHALL MAINTAIN ACCESS TO ADJACENT PARKING LOTS AT ALL TIMES,

2011 EDITION OF THE MICHIGAN MANUAL OF UNIFORM TRAFFIC CONTROL DEVICES.

PLACING OF TEMPORARY TRAFFIC CONTROL ITEMS SHALL BE DONE IN ACCORDANCE WITH THE

OWNERS WHO MAY NOT BE A PART OF THE "MISS DIG" ALERT SYSTEM.

NOTIFIED. THIS DOES NOT RELIEVE THE CONTRACTOR OF THE RESPONSIBILITY OF NOTIFYING UTILITY

WHERE PUBLIC UTILITIES HAVE NOT BEEN PREVIOUSLY LOCATED. MEMBERS WILL THUS BE ROUTINELY

EXCLUDING SATURDAYS, SUNDAYS, AND HOLIDAYS PRIOR TO BEGINNING EACH EXCAVATION IN AREAS

THE CONTRACTOR SHALL DIAL 1-800-482-7171 OR 811 A MINIMUM OF THREE FULL WORKING DAYS, FOR PROTECTION OF UNDERGROUND UTILITIES AND IN CONFORMANCE WITH PUBLIC ACT 174, 2013, STANDARD SPECIFICATIONS AND DETAILS.

AS AMENDED BY SUPPLEMENTAL SPECIFICATIONS, SPECIAL PROVISIONS AND THE CITY OF CADILLAC

MICHIGAN DEPARTMENT OF TRANSPORTATION 2020 STANDARD SPECIFICATIONS FOR CONSTRUCTION

THE IMPROVEMENTS COVERED BY THESE PLANS SHALL BE DONE IN ACCORDANCE WITH THE

WHITE PINE TRAIL LOCATION

PROJECT LOCATION

(SUNNYSIDE DRIVE)

WHITE PINE TRAIL

TITLE SHEET

MICRO PARKS

WHITE PINE TRAIL LOCATION

P&N JN:

DATE:

DESIGN:

SHEET6/11/2024

HOUK

2230214

NO SCALE

CITY OF CADILLAC MICRO PARKS

BIDDING

PLANS FOR

P&N JN:

DATE:

DESIGN:

SHEET6/11/2024

HORZ. (FT)

HOUK

2230214

CITY OF CADILLAC MICRO PARKS

BIDDING

PLANS FOR

T

R A

IN

IN

G Z

O N

E

WHITE PINE TRAIL LOCATION

AGGREGATE BASE, 6 INCH

DRIVEWAY, NONREINF CONC, 6 INCH

CROSS SLOPE

2.0% OR FLATTER

PROPOSED CONCRETE SECTION

PLAN AND TYPICAL SECTIONS

N

SUNNYSIDE DRIVE

CADILLAC SHORES DRIVE

WHITE PINE TRAIL

VISITOR BUREAU SIGN

PROPOSED

(4' X 10' CONCRETE FOOTING)

6' TALL X 10' LONG WALL

CONCRETE WALL FOR MURAL

PROPOSED FREESTANDING

BICYCLE RACKS

PROPOSED

BENCH

PROPOSED

WASTE RECEPTACLE

PROPOSED

MOUNTED SOLAR LIGHT

PROPOSED POLE

30'

50'

'2

EX HMA

FEATURES

EXERCISE

5'

4'

AND EMBANKMENT, CIP AS REQUIRED

PAID FOR AS EXCAVATION, EARTH

GRADE TO THIS LINE.

M

IN

RESTORATION

SLOPE

1:6

1'

CONCRETE, 6 INCH

DRIVEWAY, NONREINF

PROPOSED

END SECTIONS

12" CULVERT WITH

PROPOSED

P&N JN:

DATE:

DESIGN:

SHEET6/11/2024

HOUK

2230214

NO SCALE

CITY OF CADILLAC MICRO PARKS

BIDDING

PLANS FOR

2 x 6 KEYWAY

TYPICAL WALL CONSTRUCTION JOINT

(TYP.)

BACK, EACH FACE AND TOP OF WALL

(2) 3/4" CHAMFER STRIPS BACK TO

CONSTRUCTION JOINTS

REINFORCING AT WALL

STOP ALL HORZ.

CONCRETE WALL

TYPICAL WALL CONTROL JOINT

CONCRETE WALL

AT WALL CONTROL JOINTS

STOP 50% OF HORZ. REINFORCING

(TYP.)

BACK, EACH FACE AND TOP OF WALL

(2) 3/4" CHAMFER STRIPS, BACK TO

FOUNDATIONS, 3" FOR SLABS. PROVIDE AIR ENTRAINED CONCRETE FOR EXTERIOR EXPOSURES.

CONCRETE SHALL HAVE A WATER/CEMENT RATIO NOT EXCEEDING 0.45; SLUMP LIMITS: 4" FOR FOOTINGS AND 6.

EXPOSED EDGES OF CONCRETE WALL SHALL BE CHAMFERED 3/4".5.

FORM ALL CONCRETE.4.

ASTM A-1064WELDED WIRE FABRIC :

ASTM A-615 GRADE 60REINFORCING BARS :3.

f'c = 4000 PSIFOOTINGS, WALLS, PIERS :

STANDARD WEIGHT CONCRETE :

CONCRETE STRENGTH2.

(315) FOR THE MIXING, FABRICATION AND PLACEMENT OF CONCRETE, REINFORCING STEEL, AND ACCESSORIES.

STRUCTURAL CONCRETE (301); CODE REQUIREMENTS (318); AND THE MANUAL OF STANDARD PRACTICE FOR DETAILING

WORK SHALL BE PERFORMED IN ACCORDANCE WITH THE AMERICAN CONCRETE INSTITUTE (ACI) SPECIFICATIONS FOR 1.

CONCRETE NOTES

BACKFILL AND EXCAVATION PER SPECIFICATIONS.4.

EARTH FORMS ARE NOT PERMITTED UNLESS SPECIFICALLY NOTED.3.

LEAST 95% OF THE MAXIMUM DENSITY PER ASTM D-1557. COMPACTING BY FLOODING IS NOT PERMITTED.

PLACE STRUCTURAL BACKFILL IN LAYERS NOT EXCEEDING 9" LOOSE THICKNESS. COMPACT EACH LAYER TO AT 2.

THE ELEVATION NOTED, ENLARGE OR LOWER FOOTINGS AT THE DIRECTION OF THE ENGINEER.

FOUNDATIONS ARE DESIGNED BASED ON SOIL BEARING OF 2000 PSF. IF SOIL OF THIS CAPACITY IS NOT FOUND AT 1.

FOUNDATION NOTES

OWNER IS SOLELY RESPONSIBLE FOR EMPLOYING/PROVIDING SPECIAL INSPECTIONS.

SPECIAL INSPECTIONS SHALL BE PROVIDED IN ACCORDANCE WITH CHAPTER 17 OF THE BUILDING CODE. THE BUILDING 4.

THE SAME NATURE AS SHOWN FOR SIMILAR CONDITIONS.

DETAILS OF CONSTRUCTION NOT FULLY SHOWN SHALL BE PER TYPICAL CONSTRUCTION IN THE BUILDING CODE AND OF 3.

VERIFY DIMENSIONS BEFORE COMMENCING WORK. REPORT DISCREPANCIES TO THE ENGINEER.2.

CONSTRUCTION SHALL CONFORM TO THE LATEST EDITION OF THE BUILDING CODE.1.

GENERAL

SIZE

BAR

f'c = 3,000 psi

TOP BARS OTHER BARS

f'c = 4,000 psi

TOP BARS OTHER BARS

f'c = 5,000 psi

TOP BARS OTHER BARS

#3

#4

#5

#6

#7

#8

#9

28"

37"

47"

56"

81"

93"

105"

22"

29"

36"

43"

63"

72"

81"

24"

32"

40"

48"

70"

80"

91"

19"

25"

31"

37"

54"

62"

70"

22"

29"

36"

43"

63"

72"

81"

17"

22"

28"

33"

49"

55"

63"

1. TABLE VALUES ARE FOR ASTM A615 GRADE 60 UNCOATED REINFORCING AND

NORMAL WEIGHT CONCRETE.

2. CONCRETE CLEAR COVER 1" OR GREATER AND REINFORCING BAR CENTER TO

CENTER SPACING IS AT LEAST THREE (3) BAR DIAMETERS.

3. LAP SPLICE LENGTHS FOR OTHER CONDITIONS INCLUDING LIGHTWEIGHT

CONCRETE, EPOXY COATED REINFORCING, AND BUNDLED BARS SHALL BE

CALCULATED PER ACI 318.

4. TOP BARS ARE HORIZONTAL BARS WITH MORE THAN 12" OF CONCRETE CAST

BELOW THE BARS. HORIZONTAL REINFORCING IN WALLS ARE TOP BARS.

REINFORCING STEEL LAP SPLICE LENGTHS

NOTES

d

\D"

\D"

4d OR

2 1/2" MIN.

OFFSET

REBAR BENDS & END HOOKS

ALL BENDS SHALL BE MADE COLD

\D" : 10d FOR #14 AND #18

\D" : 8d FOR #9 THRU #11

\D" : 6d FOR #3 THRU #8

NOTE

SCALE : NONE

SCALE : NONE

FREESTANDING CONCRETE WALL

(1) #5 BAR CONT.

OR SLAB

FINISHED GRADE

8"

CONCRETE STEM WALL

3 1/2" CLR.

CONCRETE FOOTING

#5 BARS HORZ. @ 12" o.c.

#5 BARS VERT. @ 12" o.c.

4'-0"

#5 BARS @ 12" o.c.

(4) #5 BARS

NOTES

20"

M I N

SUBGRADE

COMPACTED

5" CLR.

3" CLR.

GENERAL STRUCTURAL NOTES

1. PROVIDE CONSTRUCTION JOINT OR

CONTROL JOINT 12'-6" o.c. MAXIMUM.

P L

A N

W A

L L

H E

I G

H T

ALTERNATE HOOK DIRECTION

#5 DOWEL @ 12" o.c.

12"

36"

M A

X

H E

I G

H T

WHITE PINE TRAIL LOCATION

EXPOSED EDGES

3/4" CHAMBER

(BOTH SIDES)

WALL PAINTING

FINISH FOR MURAL

SMOOTH CONCRETE

CONCRETE WALL DETAILS

File details come from the government source that posted it. Updated .