03a. Lead-Based Paint Survey B1340, 3 Feb 03.pdf

PDF 698 KB Posted

Attached to
FTQW 235100, DSN Repair Hangar Doors
Solicitation number
23-5100
Issued by

About this file

This letter report from SUNEX Inc. documents the results of a lead-based paint survey conducted on January 27, 2003, in Building 1340 at Eielson AFB, Alaska. The survey was performed by James H. Johnson using a NITON 703A XRF Spectrum Analyzer to test interior ceiling and upper wall components, with a threshold of 1 mg/cm2 or greater lead content defining lead-based paint.

The survey concluded that no lead-based paint was found in Building 1340. The report was certified by SUNEX Inc.'s President James H. Johnson, who held valid EPA Lead Firm Certification (AK-02-042003-2074) and EPA Lead Inspector/Risk Assessor Certification (AK-02-052003-1482/3) at the time of inspection. The survey was conducted to support AC work in the building, as requested by Sgt. Brian Keenan of the 354th CES/CEOE.

View the file

Other files

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

SUNEXInc.

2003 February 03

Sgt. Brian Keenan 3 54th CES/CEOE 2258 Central Ave.

Eielson AFB, AK 99702

Phone 907-377-5186, email Brian.Keenan@eielson.afmil

Reference: Lead-Based Paint Survey, Building 1340

Dear Sgt. Keenan:

Attached are the results of a lead-based paint survey of interior ceiling and upper wall components in Building 1340, Eielson AFB, Alaska. The survey is intended to support AC work in this building.

The survey was performed by James H. Johnson on 2003 January 27. Lead paint tests w re made with a NITON 703A XRF Spectrum Analyzer, SNU882NR3842, using 1 mg/cm2 r greater lead content as the definition of lead-based paint. Positive lead paint results usin this criterion are highlighted in the data table. XRF sample locations are noted on the attache plan.

The following are the conclusions from this survey:

• No lead-based paint was found.

If you have any questions about this information, please give me a call.

Sincerely, SUNEX, Inc.

James H. Johnson President

EPA Lead Firm Certification AK-02-042003-2074 Expires 04/20/2003

EPA Lead Inspector/Risk Assessor Certification AK-02-052003-1482/3, Expires 06/02/2003

Niton® state-ofthe-artXRF teclmokgy 121 Trinidad Drive Fairbanks, AK 99709-2902

907-457-5478 phone 907-457-5479 fax email sunex@ptialaska.net

•1

\'.,.1-

Site: Eielson AFB, Bldg 1340 Data: XRF Lead-Based Paint Survey Date: 1/27/2003 Ranges (NEG<INC<POS): Device PCS, NITON 703A, SNU882NR3842

XLNo Room Side Structure Feature Substrate Condition Color Result Pbmglcm2 Pb Error

121 Calibrate 0.0 NEG 0.00 0.15 122 Calibrate 0.0 NEG 0.00 0.01 123 Calibrate 0.0 NEG 0.00 0.01 124 Calibrate 1.0 POS 0.99 0.11 125 Calibrate 1.0 POS 1.03 0.14 126 Calibrate 1.0 POS 1.00 0.13 127 Interior Ceiling Truss . Web L-lron Metal Fair Beige NEG 0.30 0.35 128 Interior Ceiling Truss Chord Top Metal Fair Beige NEG 0.26 0.33 129 Interior Ceiling Ceiling Pan Bottom Metal Intact Beige NEG 0.02 0.07 130 Interior Ceiling I-Beam Web Metal Intact Beige NEG 0.12 0.40 131 Interior Ceiling Truss Chord Bottom Metal Fair Beige NEG 0.17 0.28 132 Interior Ceiling Cross Tie L-lron Metal Poor Beige NEG 0.11 0.39 133 Interior Ctr Floor Plywood Plywood Poor Brown NEG 0.01 0.17 134 Interior Ceiling Cross Tie L-lron Metal Fair Beige NEG 0.02 0.21 135 Interior Ceiling Truss Chord Top Metal Intact Beige NEG 0.09 0.38 136 Interior Ceiling Truss Web Metal Fair Beige NEG 0.10 0.43 137 Interior Ceiling Column Web Metal Intact Beige NEG 0.06 0.23 138 Interior Ceiling Pace HVAC Bracket Metal Fair Beige NEG 0.13 0.27 139 Interior W/Ctr Column Web Metal Intact Beige NEG 0.02 0.15 140 Interior W/NW Wall Panel Metal Fair Gray NEG 0.03 0.09 141 Interior N/NW Wall Panel Metal Fair Gray NEG 0.02 0.01 142 Interior N/NW Column Flange Metal Fair Beige NEG 0.08 0.24 143 Calibrate o.o NEG 0.00 0.01 144 Calibrate 0.0 NEG 0.00 0.08 145 Calibrate 0.0 NEG 0.00 0.01 146 Calibrate 1.0 POS 1.12 0.15 147 Calibrate 1.0 POS 1.00 0.09

--446- -Calibrate-1..0 POS 1.00 0.13

SUNEX, Inc. 1

~li,.....la:;i'·U

140 lt=:=t

141,142

BLD.G. 1340

138,139

0 I

127-137

SUN EX I 121 Trinidad Drive , n C · Fairbanks, AK 99709

XRF Lead-Based Paint Survey

Building 1340 XRF Sample Locations

Date: 2003 Feb 07l 8cale: None IDrawnBy:JHJ

SUNEXInc.

2002 September 04

Sgt. Brian Keenan 354th CES/CECS 2258 Central Ave.

Eielson AFB, AK 99702

Phone 907-3 77-5186, email brian.keenan@eielson.af mil

Reference: XRF Lead-Based Paint Survey, Building 1340

Dear Sgt. Keenan:

Attached are the results of a lead-based paint survey of the hangar floor and the Egress Office floor, Building 1340, Eielson AFB, Alaska.

The survey was performed on 2002 September 04. Lead paint tests were made with a NITON 703A Spectrum Analyzer, SNU739NR1267, using 1 mg/cm2 or greater lead content as the definition of lead-based paint. Positive lead paint results using this criterion are highlighted in the data table . The locations of the XRF test sites are shown on the attached drawing.

Following are the conclusions from this survey:

• No lead-based paint was found on any of the components that were tested.

If you have any questions about this information, please give me a call .

Sincerely, SUNEX, Inc.

James H. Johnson President

EPA Lead Firm Certification AK-02-042003-2074 Expires 04/20/2003

EPA Lead Inspector/Risk Assessor Certification AK-02-052003 - 1482, Expires 06/02/2003

Niton® state-of-the-art XRF technolq?y 121 Trinidad Drive Fairbanks, AK 99709-2902

907-457-54 78 phone 907-457-54 79 fax e mail sunex@ptialaska.net

Site: Eielson AFB, Building 1340, Hangar Floor Data: XRF Lead-Based Paint SuNey Dat~/41:2002 Ranges (NEG<INC<POS): Device PCS, NITON 703A, SNU739NR1267

XLNo Room Side Structure Feature Substrate Condition Color Result Pb mg/cm2 Pb Error

589 Calibrate 0.0 NEG 0.00 0.18 590 Calibrate 0.0 NEG 0.00 0.02 591 Calibrate 0.0 NEG 0.00 0.02 592 Calibrate 1.0 POS 0.96 0.10 593 Calibrate 1.0 POS 1.03 0.11 594 Calibrate 1.0 POS 1.00 0.11 595 Hangar E Floor Floor Concrete Poor Gray NEG 0.00 0.01 596 Hangar E Floor Traffic Stripe Concrete Fair Yellow NEG 0.00 0.01 597 Hangar E/SE Floor Floor Concrete Poor Gray NEG 0.00 0.01 598 Hangar E/SE Floor Floor Concrete Poor Gray NEG 0.01 0.08 599 Hangar W/SW Floor Floor Concrete Poor Gray NEG 0.00 0.01 600 Hangar w Floor Traffic Stripe Concrete Fair Yellow NEG 0.00 0.01 601 Hangar w Floor Traffic Stripe Concrete Poor Yellow NEG 0.00 0.01 602 Hangar w Floor Apron, Skid Plate Metal Poor Red NEG 0.00 0.09 603 Hangar N Ctr Floor Sm. Black Circle Concrete Poor Black NEG 0.01 0.02 604 Hangar W/NW Floor Apron, Traffic Stripe Concrete Poor Yellow NEG 0.27 0.08 605 Hangar N Floor Floor Concrete Poor Gray NEG 0.00 0.11 606 Hangar E/NE Floor Traffic Stripe Concrete Poor Yellow NEG 0.00 0.01 607 Hangar E Ctr Floor Lg. Black Circle Concrete Poor Black NEG 0.02 0.06 608 Hangar E Ctr Floor Lg. Black Circle Concrete Poor Black NEG 0.04 0.11 609 Hangar E Ctr Floor Drain Grate Metal Poor Black NEG 0.62 0.13 610 Hangar E Ctr Floor Lg. Black Circle Concrete Poor Yellow NEG 0.00 0.01 611 Hangar E Ctr Floor Lg. Black Circle Concrete Poor Yellow NEG 0.00 0.01 612 Egress Off. Ctr Floor Floor Concrete Poor Gray NEG 0.01 0.07 613 Egress Off. N/NW Floor Floor Concrete Poor Gray NEG 0.00 0.01

6.14 Egress Off. SISE Floor Floor Concrete Poor Gray NEG 0.00 0.03 615 Calibrate 0.0 NEG 0.00 0.02 616 Calibrate 0.0 NEG 0.03 0.10 617 Calibrate 0.0 NEG 0.00 0.02 618 Calibrate 1.0 POS 1.09 0.11 l-"' .1• SUNEX, Inc. 1

"l j '

Site: Eielson AFB, Building 1340, Hangar Floor Data: XRF Lead-Based Paint Survey

-oare: 9!4-1200F¥.zr------ Ranges (NEG<!NC<POS): Device PCS, NITON 703A, SNU739NR1267

XLNo Room

Side Structure

Calibrate 1.0 Calibrate 1.0

Feature Substrate Condition Color

SUNEX, Inc.

Result

POS

POS

Pb mg/cm2 Pb Error

1.04 1.04

0.10 0.07

SUNEX Consulting & Analytical Services

01 June 01

SSgt. Jeremy Byers 354th CES/CEOEC 2258 Central Avenue Eielson AFB, AK 99702

Phone 907-377-2595, email jeremy.byers@eielson.af.mil

Reference: Lead Based Paint Survey, Building 1340

Dear SSgt. Byers:

Attached are the results of a lead based paint survey of the exterior of Building 1340, Eielson AFB. The survey was performed on 01 May 23 with a NITON 703A XRF Spectrum Analyzer, SNU882NR0641.

Paint that has 1 mg/cm2 or greater lead content is considered to be lead paint. Positive lead paint results based on this criteria are highlighted in the data table. Where components are numbered, they are in ascending order from left to right when viewed from the front. XRF sample locations are noted on the attached drawing.

Following are the conclusions from this survey:

1. There is lead based paint on a fire hose connection on the E-NE side of the building.

If you have any questions about this information, please give me a call.

Sincerely, SUNEX Consulting & Analytical Services

James H. Johnson

Niton® state-of-the-art XRF technology 121 Trinidad Drive Fairbanks, AK 99709-2902

907-457-54 78 phone 907-457-54 79 fax email sunex@ptialaska.net

C C C ·~

Survey: LBP, XRF Data Site: Eielson AFB Building 1340, Hangar Date: 5/23/2001 Ranges (NEG<INC<POS): Device PCS NITON 703A, SNU882NR0641

XLNo Room Side Strc Feat Sub Cnd Cir Result Pb mg/cm2 ± Pree

152 Calibrate 0.0 NEG 0.00 0.02 153 Calibrate 0.0 NEG 0.00 0.02 154 Calibrate 0.0 NEG 0.00 0.02 155 Calibrate 1.0 NEG 0.90 0.08 156 Calibrate 1.0 POS 0.96 0.12 157 Calibrate 1.0 NEG 0.90 0.09 158 Exterior N-NW Wall Foundation 3' Concrete Fair Beige NEG 0.00 0.02 159 Exterior N-NW Wall Siding 6' Metal Intact Beige NEG 0.00 0.07 160 Exterior N-NW Wall Drip Edge 5' Metal Intact Gray NEG 0.04 0.16 161 Exterior N-NW Door5 Door 7' Metal Poor Beige NEG 0.01 0.16 162 Exterior N Door5 Casing 4' Metal Poor Beige NEG 0.03 0.12 163 Exterior N Door4 Door 4' Metal Poor Gray NEG 0.10 0.58 164 Exterior N Door4 Casing 6' Metal Poor Gray NEG 0.04 0.35 165 Exterior N Door4 Door 6' Metal Poor Gray NEG 0.05 0.19 166 Exterior N OH Door Jamb 5' Metal Intact Gray NEG 0.14 0.36 167 Exterior N OH Door Panel 6' Metal Intact Beige NEG 0.05 0.08 168 Exterior N OH Door Jamb 7' Metal Intact Beige NEG 0.02 0.07 169 Exterior N Wall Wall 4' Concrete Poor Beige NEG 0.01 0.10 170 Exterior N Window Sill Metal Poor Gray NEG 0.02 0.14 171 Exterior N Window Sill Metal Intact White NEG 0.00 0.00 172 Exterior N Door3 Door 6' Metal Poor Gray NEG 0.06 0.13 173 Exterior N Door3 Jamb 6' Metal Poor Gray NEG 0.10 0.63 174 Exterior N Wall Corner Trim Metal Intact Gray NEG 0.01 0.03 175 Exterior N Folding Door Door 6' Metal Poor Gray NEG 0.01 0.09 176 Exterior N Folding Door Corner Metal 7' Metal Fair Gray NEG 0.02 0.02 177 Exterior N Folding Door Jamb 5' Metal Poor Gray NEG 0.03 0.06 178 Exterior N-NE Door2 Door 3' Metal Intact Gray NEG 0.00 0.06 179 Exterior

N-NE - Door2 - Casir,-g-- --S'--- --Metal-- --1Rta€t- ------Gr:aY- --NEG.__Q.04 QJO

180 Exterior N-NE Door 1 Door 7' Metal Intact Gray NEG 0.00 0.07

SUNEX Consulting and Analytical Services 1

C C C L, Survey: LBP, XRF Data Site: Eielson AFB Building 1340, Hangar Date: 5/23/2001 Ranges (NEG<INC<POS): Device PCS NITON 703A, SNU882NR0641

XLNo Room Side Strc Feat Sub Cnd Cir Result Pb mg/cm2 ± Pree

181 Exterior N-NE Wall Vent Louver Metal Poor Beige NEG 0.03 0.06 182 Exterior E-NE Fire Connect. Pipe Metal Poor Red POS 1.19 0.14 183 Exterior E Wall Wall 2' Concrete Poor Beige NEG 0.01 0.14 184 Exterior E Wall Siding 10' Metal Intact Gray NEG 0.02 0.01 185 Exterior S-SE Hangar Door 2 Base Metal Poor Beige NEG 0.01 0.01 186 Exterior S-SE Hangar Door 2 Panel 3' Metal Poor Beige NEG 0.01 0.13 187 Exterior S-SE Hangar Door 2 Brace Metal Poor Beige NEG 0.05 0.19 188 Exterior S-SE Hangar Door 2 Panel 6' Metal Poor White NEG 0.05 0.14 189 Exterior S-SE Hangar Door 2 Panel 8' Metal Intact Gray NEG 0.02 0.03 190 Exterior S-SE Hangar Door 2 Egress Door 6' Metal Poor White NEG 0.00 0.02 191 Exterior S-SE Hangar Door 2 Casing 5' Metal Poor White NEG 0.01 0.05 192 Exterior S-SE Hangar Door 2 Corner Trim Metal Fair White NEG 0.00 0.09 193 Exterior S-SE Hangar Door 2 Base Metal Poor Red NEG 0.01 0.09 194 Exterior s Wall Column Concrete Poor Beige NEG 0.00 0.01 195 Exterior s Hangar Door 1 Panel 2' Metal Poor Beige NEG 0.04 0.22 196 Exterior s Hangar Door 1 Base Edge Metal Poor Beige NEG 0.02 0.23 197 Exterior S-SW Hangar Door 1 Panel 6' Metal Poor White NEG 0.03 0.19 198 Exterior S-SW Hangar Door 1 Base Metal Poor Beige NEG 0.01 0.05 199 Exterior S-SW Hangar Door 1 Egress Door 4' Metal Fair White NEG 0.01 0.17 200 Exterior S-SW Hangar Door 1 Casing 3' Metal Fair White NEG 0.05 0.18 201 Exterior S-SW Hangar Door 1 Panel 4' Metal Poor Beige NEG 0.01 0.06 202 Exterior S-SW Entry Floor Concrete Poor Gray NEG 0.03 0.11 203 Exterior S-SW Entry Door Metal Intact White NEG 0.02 0.16 204 Exterior w Wall Wall 3' Concrete Poor Beige NEG 0.03 0.14 205 Exterior w Wall Siding 7' Metal Intact Gray NEG 0.00 0.13 206 Exterior W-NW Window Sash Metal Intact White NEG 0.00 0.06 207 Calibrate 0.0 NEG 0.00 0.01 208 --- - C-a7iorate o:o-- - --- NEG __ 000 0.01 --- 209 Calibrate 0.0 NEG 0.00 0.02

SUNEX Consulting and Analytical Services 2

C Survey: LBP, XRF Data Site: Eielson AFB Building 1340, Hangar Date: 5/23/2001 Ranges (NEG<INC<POS): Device PCS NITON 703A, SNU882NR0641

XLNo Room

Side Strc

Calibrate 1.0 Calibrate 1.0 Calibrate 1.0

Feat Sub Cnd Cir

SUNEX Consulting and Analytical Services

Result

NEG

NEG

POS

Pb mg/cm2 ± Pree

0.95 0.93 0.97

0.12 0.11 0.12

C

File details come from the government source that posted it. Updated .