03 FTQW 21-1004 SOW Atch A.pdf
PDF 170 KB Posted
- Attached to
- Airfield Regulators Repair Federal contract opportunity
- Solicitation number
- FA500421B0003
About this file
This document contains a statement of work and related federal contract opportunity notice. The statement of work outlines the requirement to remove and replace existing constant current regulators and airfield lighting control and monitoring systems at Eielson Air Force Base in Alaska. It lists 36 existing pieces of equipment to be replaced. The related solicitation seeks bids to fulfill this requirement, with an estimated value between $1 million and $5 million. Interested offerors must attend a mandatory site visit on May 26, 2021 and submit any questions by June 2. Bids are due by June 11, 2021 and will be opened the same day. The solicitation and any additional information is available on SAM.gov. The primary point of contact for questions is MSgt Matthew Hagan of the Department of the Air Force Pacific Air Forces.
View the file
Other files for this federal contract opportunity
| File | Type | Posted |
|---|---|---|
| Solicitation Amendment - FA500421B00030001.pdf | ||
| Question and Answer.pdf | ||
| Solicitation - FA500421B0003.pdf | ||
| 08 FTQW 21-1004 Submittal Register 18 FEB 21.xls | XLS spreadsheet | |
| JA Brand Name_Redacted.pdf | ||
| 08 FTQW 21-1004 Project Specifications 18 FEB 21.pdf | ||
| Wage Determination AK20210001.pdf | ||
| 03 FTQW 21-1004 SOW Repair Airfield Regulators 29 MAR 21.pdf |
On GovTribe
Work with this file on GovTribe
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
1 ALCMS Cell 2 Incoming Supply Cell 3 North PAPI 4Kw 5 6.6 amp 480v 4 South PAPI 4Kw 5 6.6 amp 480v 5 Taxiway Loop #7 10Kw 5 6.6 amp 480v 6 Taxiway Loop #8 10Kw 5 6.6 amp 480v 7 Taxiway E (5/1 & 5/2) 10Kw 5 6.6 amp 480v 8 Test Bench 6.6 amp 10Kw 5 6.6 amp 480v 9 Runway 14/32 (1) 15Kw 5 6.6 amp 480v 10 Runway 14/32 (2) 15Kw 5 6.6 amp 480v 11 Aproach 1 South 30Kw 5 20 amp 480v 12 Test Bench 20amp 20Kw 5 20 amp 480v 13 Approach 2 South 30Kw 5 20 amp 480v 14 Approach 3 South 30Kw 5 20 amp 480v 15 Threshold South 30Kw 5 20 amp 480v 16 Approach 1 North 30Kw 5 20 amp 480v 21 ALCMS Cell 22 Incoming Cell 23 Approach 2 North 30Kw 5 20 amp 480v 24 Approach 3 North 30Kw 5 20 amp 480v 25 Threshold North #1 30Kw 5 20 amp 480v 26 Spare 20Kw 5 20 amp 480v 27 Threshold North #2 30Kw 5 20 amp 480v 28 Spare 20Kw 5 20 amp 480v 29 Runway 14/32 (3) 15Kw 5 6.6 amp 480v 30 Spare 30 Kw 5 20 amp 480v 31 Runway 14/32 (4) 15Kw 5 6.6 amp 480v 32 Spare 15Kw 5 6.6 amp 480v 33 Taxiway Alpha 10Kw 5 6.6 amp 480v 34 Taxiway Fox South/Charlie/Delta/Golf 10Kw 5 6.6 amp 480v 35 Taxiway Bravo 4Kw 5 6.6 amp 480v 36 Distance Remaining Markers 10Kw 5 6.6 amp 480v 38 Taxiway Fox North 4Kw 5 6.6 amp 480v
CCR Brightness Steps (3 or 5)
CCR size(KW)Circuit IDCELL CCR output (6.6 amp or 20 amp)
CCR input voltage
Existing CCR Configuration
| Line Drawings.pdf |
| Line A |
| Line B |
File details come from the government source that posted it. Updated .