03 512-23-108-VDCI_VAMC BT_Renovate C Segregate Comp_Drawings-BID_2024-06-13.pdf
PDF 6 MB Posted
- Attached to
- Y1DA--512-23-108 - Renovate C-Segregated Compounding Area for Hazardous Compounding (CON)
- Solicitation number
- 36C24525B0006
About this file
These architectural and engineering design documents detail a renovation project for the VA Maryland Healthcare System located in Baltimore, Maryland. The project involves renovating the C-Segregated Compounding Area for Hazardous Compounding at the VA Medical Center, specifically focused on upgrading areas including the Pharmacy (BA121K), Anteroom (BA121L), Hood Room A (BA121O), Hood Room B (BA121P), and Hood Room C (2C-126). The comprehensive bid documents are dated May 17, 2024, and include architectural, mechanical, electrical, plumbing, and fire suppression plans across basement and second floor levels.
The renovation encompasses multiple technical disciplines, with specific focus on creating a modern, compliant pharmaceutical compounding environment. The design incorporates advanced features such as specialized hood rooms, mobile workstations, stainless steel countertops, refrigeration units, and comprehensive safety systems including fire alarm, sprinkler, and infection control provisions. The project adheres to multiple regulatory standards including NFPA, International Building Code, VA Design Manuals, and USP 797 and 800 standards for sterile and hazardous drug preparation. The work is fully sprinklered and designed to maintain continuous operational capabilities during the phased construction process.
View the file
Other files
On GovTribe
Work with this file
- Download the original file
- Contacts named in this file
- Similar government files
- Ask GovTribe AI about this file
Text version
PROJECT
G-001
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
BID DOCUMENTS
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans
Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseENGINEER OF RECORD STAMPSUBCONSULTANTS
321 4 5 6 7 8 9 10
05/17/2024Revisions: Date:
DELTA ENGINEERS, ARCHITECTS & SURVEYORS
8401 CONNECTICUT AVE SUITE 350
CHEVY CHASE, MARYLAND 20815
301.718.0080
MORABITO CONSULTANTS, INC.
STRUCTURAL ENGINEERING
952 RIDGEBROOK ROAD, SUITE 1700
SPARKS, MARYLAND 21152
410.467.2377KOFFEL ASSOCIATES, INC.
8815 CENTRE PARK DR STE 200
COLUMBIA, MD 21045
410.750.2246
VETERAN DESIGN & CONSTRUCTION INC.
5523 RESEARCH PARK DRIVE SUITE 110
BALTIMORE, MARYLAND 21228
443.543.5081
512-23-108RENOVATE C-SEGREGATED
COMPOUNDING AREA FOR
HAZARDOUS COMPOUNDING
VAMC BALTIMORE
COVER SHEET
INDEX OF DRAWINGS
SHEET DISCIPLINE TITLE SHEET NO.
G-001 GENERAL COVER SHEET 1
G-002 ARCHITECTURAL ARCHITECTURAL NOTES, SYMBOLS AND ABBREVIATIONS 2
AD-101 ARCHITECTURAL ARCHITECTURAL FLOOR PLANS - DEMOLITION 3
AL-101 ARCHITECTURAL ARCHITECTURAL LIFE SAFETY PLAN 4
AS-101 ARCHITECTURAL ARCHITECTURAL FLOOR PLANS - NEW WORK 5
AS-102 ARCHITECTURAL ARCHITECTURAL - FINISH FLOOR PLAN 6
AS-201 ARCHITECTURAL ARCHITECTURAL - ELEVATIONS 7
AS-501 ARCHITECTURAL ARCHITECTURAL - DETAILS 8
AS-601 ARCHITECTURAL ARCHITECTURAL - SCHEDULES 9
MH-001 MECHANICAL MECHANICAL - GENERAL NOTES, SYMBOLS & ABBREVIATIONS 10
MD-101 MECHANICAL MECHANICAL - FLOOR PLANS - DEMOLITION 11
MH-101 MECHANICAL MECHANICAL - FLOOR PLANS - NEW WORK 12
MH-102 MECHANICAL MECHANICAL - AREA C SERVICE BAY PART PLANS 13
MH-501 MECHANICAL MECHANICAL DETAILS 14
MH-601 MECHANICAL MECHANICAL SCHEDULES 15
MH-701 MECHANICAL MECHANICAL CONTROLS 16
PL-001 PLUMBING PLUMBING - GENERAL NOTES, SYMBOLS & ABBREVIATIONS 17
PD-101 PLUMBING PLUMBING - FLOOR PLANS - DEMOLITION 18
PL-101 PLUMBING PLUMBING - FLOOR PLANS - NEW WORK 19
PL-501 PLUMBING PLUMBING DETAILS AND SCHEDULES 20
ES-001 ELECTRICAL ELECTRICAL - SYMBOLS & ABBREVIATIONS 21
ED-101 ELECTRICAL ELECTRICAL - FLOOR PLANS - DEMOLITION 22
ES-101 ELECTRICAL ELECTRICAL - LIGHTING PLANS - NEW WORK 23
ES-201 ELECTRICAL ELECTRICAL - POWER PLANS - NEW WORK 24
ES-202 ELECTRICAL ELECTRICAL - POWER PLANS - NEW WORK 25
ES-501 ELECTRICAL ELECTRICAL - RISER DIAGRAMS 26
ES-601 ELECTRICAL ELECTRICAL SCHEDULES 27
FA-001 FIRE PROTECTION FIRE ALARM - PROJECT NOTES, SYMBOLS AND ABBREVIATIONS 28
FAD-101 FIRE PROTECTION FIRE ALARM - FLOOR PLANS - DEMOLITION 29
FA-101 FIRE PROTECTION FIRE ALARM - FLOOR PLANS - NEW WORK 30
FA-501 FIRE PROTECTION FIRE ALARM DETAILS 31
FS-001 FIRE PROTECTION FIRE SUPPRESSION - PROJECT NOTES, SYMBOLS AND ABBREVIATIONS 32
FSD-101 FIRE PROTECTION FIRE SUPPRESSION - FLOOR PLANS - DEMOLITION 33
FS-101 FIRE PROTECTION FIRE SUPPRESSION - FLOOR PLANS - NEW WORK 34
FS-501 FIRE PROTECTION FIRE SUPPRESSION DETAILS 35
PROJECT MAP
MAP
RENOVATE C-SEGREGATED COMPOUNDING AREA FOR HAZARDOUS COMPOUNDING
VA MARYLAND HEALTHCARE SYSTEM - VISN 5
NRM PROJECT - 512-23-108
BALTIMORE, MD. 21201
BID SUBMITTAL - CONSTRUCTION DOCUMENTS MAY 17, 2024
DS
APPLICABLE CODES
TYPE DESCRIPTION
BUILDING CODE
INTERNATIONAL BUILDING CODE (IBC) 2021
DEPARTMENT OF VETERANS AFFAIRS DESIGN MANUAL AND DESIGN GUIDES
AMERICANS WITH DISABILITIES ACT (ADA)
ACCESSIBILITY CODE ICC/ANSI A117.1-09 ACCESSIBLE AND USABLE BUILDINGS AND FACILITIES 2020 BUILDING CODE
FIRE CODE
NFPA 1, 2021
VA FIRE PROTECTION DESIGN MANUAL (VAFPDM) - JUNE 2021 EDITION
NFPA 101®, LIFE SAFETY CODE® (LSC) - 2021 EDITION
NFPA 13, STANDARD FOR THE INSTALLATION OF SPRINKLER SYSTEMS - 2022 EDITION
NFPA 25, STANDARD FOR THE INSPECTION, TESTING, AND MAINTENANCE OF WATER-BASED FIRE PROTECTION
SYSTEMS - 2023 EDITION
NFPA 45, STANDARD ON FIRE PROTECTION FOR LABORATORIES USING CHEMICALS, 2019 EDITION
NFPA 70, NATIONAL ELECTRICAL CODE - 2023 EDITION
NFPA 72, NATIONAL FIRE ALARM AND SIGNALING CODE - 2022 EDITION
INTERNATIONAL BUILDING CODE (IBC) - 2021 EDITION (AS AMMENDED)
MECHANICAL CODE
INTERNATIONAL MECHANICAL CODE (IMC) - EDITION 2021
2021 INTERNATIONAL ENERGY CONSERVATION CODE (IECC)
2021 NATIONAL FIRE PROTECTION ASSOCIATION (NFPA) 1: FIRE CODE
2021 NFPA 101: LIFE SAFETY CODE
2019 AMERICAN SOCIETY OF HEATING, REFRIGERATING, AND AIR CONDITIONING ENGINEERS (ASHRAE) STANDARD 62.1
2022 ASHRAE STANDARD 90.1 ENERGY STANDARD FOR BUILDINGS EXCEPT LOW-RISE RESIDENTIAL BUILDINGS
ANSI/ AMERICAN SOCIETY OF MECHANICAL ENGINEERS (ASME) B31.1, B31.3 AND B31.9
VA HVAC DESIGN MANUAL, REV 3/1/22
NFPA 45 STANDARD ON FIRE PROTECTION FOR LABORATORIES USING CHEMICALS
PLUMBING CODE
INTERNATIONAL PLUMBING CODE (IPC)
2021 INTERNATIONAL ENERGY CONSERVATION CODE (IECC)
2021 NATIONAL FIRE PROTECTION ASSOCIATION (NFPA) 1: FIRE CODE, AND ITS MANDATORY REFERENCED CODES AND
STANDARDS
2021 NFPA 101: LIFE SAFETY CODE, AND ITS MANDATORY REFERENCED CODES AND STANDARDS
VA PLUMBING DESIGN MANUAL, REV 5/1/2021
NFPA 45 STANDARD ON FIRE PROTECTION FOR LABORATORIES USING CHEMICALS
ELECTRICAL CODE
NFPA 70 - NATIONAL ELECTRICAL CODE, 2023
NFPA 72 - NATIONAL FIRE ALARM CODE, 2022
NFPA 110 - EMERGENCY AND STANDBY POWER SYSTEMS, 2022
NFPA 99 HEALTHCARE FACILITIES
NFPA 101 LIFE SAFETY CODE
VA ELECTRICAL DESIGN MANUAL (EDM)
VA LIGHTING DESIGN MANUAL (LDM)
NATIONAL ELECTRICAL MANUFACTURERS ASSOCIATION (NEMA)
INSTITUTE OF ELECTRICAL AND ELECTRONICS ENGINEERS (IEEE)
NFPA 45 STANDARD ON FIRE PROTECTION FOR LABORATORIES USING CHEMICALS
ILLUMINATING ENGINEERING SOCIETY (IES) DESIGN GUIDELINES
USP 797 STANDARD GOVERNING THE STERILE PREPARATION OF COMPOUNDED PHARMACEUTICALS
USP 800 STANDARDS FOR SAFE HANDLING OF HAZARDOUS DRUGS
MC
A
ACT ACOUSTICAL CEILING TILE
ADJ ADJACENT
AFF ABOVE FINISH FLOOR
ALUM ALUMINUM
ANOD ANODIZED
@ AT
B
BLKG BLOCKING
C
CAB CABINET
CCT CUBICLE CURTAIN TRACK
CG CORNER WALL GUARD
CLG CEILING
CLO CLOSET
CMU CONCRETE MASONRY UNIT
CONC CONCRETE
CONT CONTINUOUS
CORR CORRIDOR
CSS CLINICAL SERVICE SINK
CPT CARPET
CT CERAMIC TILE
D
DET DETAIL
DIA DIAMETER
DIM DIMENSION
DR DOOR
DWG DRAWING
DWR DRAWER
E
EA EACH
EG END WALL GUARD
ELEC ELECTRIC(AL)
ELEV ELEVATOR/ ELEVATION
EMER EMERGENCY
EQUIP EQUIPMENT
ETR EXISTING TO REMAIN
EWC ELECTRIC WATER COOLER
EXIST EXISTING
EXT EXTERIOR
F
FA FIRE ALARM
FT FEET/ FOOT
FD FLOOR DRAIN
FE FIRE EXTINGUISHER
FEC FIRE EXTINGUISHER CABINET
FHS FIRE HOSE STATION (CABINET)
FHV FIRE HOSE VALVE CABINET
FLR FLOOR(ING)
FLUOR FLUORESCENT
FR FRAME
FVC FIRE VALVE CABINET
G
GALV GALVANIZE(D)
GB GRAB BAR
GC GENERAL CONTRACTOR
GOVT GOVERNMENT
GWB GYPSUM WALL BOARD
H
HC HOLLOWCORE
HDW HARDWARE
HGT HEIGHT
HM HOLLOW METAL
HORIZ HORIZONTAL
I
IB INTEGRAL BASE
ID INSIDE DIAMETER
IN INCH(ES)
INT INTERIOR
INTEG INTEGRAL
INTLK INTERLOCK
L
LAM LAMINATE(D)
LAV LAVATORY
LB POUND
LT LENGTH
LH LEFT HAND
LHRB LEFT HAND REVERSE BEVEL
LOCK LOCKERS
LVR LOUVER
M
MA MEDICAL AIR
MAX MAXIMUM
MED MEDICAL/MEDICATIONS
MFR MANUFACTURER
MIN MINIMUM
MISC MISCELLANEOUS
MO MASONRY OPENING
MTL METAL
N
N NORTH/ NITROGEN
NC NURSE CALL
NEG NEGATIVE
NIC NOT IN CONTRACT
NO NUMBER
NOM NOMINAL
NTS NOT TO SCALE
O
OA OVERALL
OC ON CENTER
OD OUTSIDE DIAMETER
OH OPPOSITE HAND
O/OX OXYGEN
OPG OPENING
P
PL PLATE
PLAM PLASTIC LAMINATE
PLYWD PLYWOOD
PNL PANEL
PNT PAINT
PR PAIR
PNT PAINT(ED)
PRT PARTITION
R
RB RESILIENT BASE
REQ REQUIRED
RESIL RESILIENT
REV REVISED
RH RIGHT HAND
RHRB RIGHT HAND REVERSE BEVEL
RO ROUGH OPENING
RCP REFLECTED CEILING PLAN
S
S SOUTH
SAB SOUND ATT. BATTS
SAFB SOUND ATT. FIRE BLANKET
SCW SOLID CORE WOOD
SEAL SEALANT
SECT SECTION
SHT SHEET
SIM SIMILAR
SPEC SPECIFICATION(S)
SQ SQUARE
SSM SOLID SURFACE MATERIAL
SS STAINLESS STEEL
SSV SEAMLESS SHEET VINYL
STC SOUND TRANSMISSION CLASS
STL STEEL
STN STAIN
STOR STORAGE
STRUCT STRUCTURAL
SV SHEET VINYL
T
TC TERRA COTTA
TEL TELEPHONE
TEMP TEMPORARY
THK THICK(NESS)
TOC TOP OF CURB
TOIL TOILET
TOS TOP OF SLAB/ TOP OF STEEL
TPTN TOILET PARTITION
TV TELEVISION
TW TOP OF WALL
TYP TYPICAL
TZ TERRAZZO
U
UNO UNLESS NOTED OTHERWISE
UON UNLESS OTHERWISE NOTED
UL UNDERWRITERS LAB.
V
VAC VACUUM
VB VAPOR BARRIER
VCT VINYL COMPOSITION TILE
VERT VERTICAL
VIF VERIFY IN FIELD
VWC VINYL WALL COVERING
W
W WEST
W/ WITH
WC WATER CLOSET/
WATER COOLER/
WALL COVERING
WD WOOD
WG WIRE GLASS
WH WALL HUNG
W/O WITHOUT
WP WATERPROOF(ING)
WR WATER RESISTANT
WS WEATHERSTRIPPING
WSCT WAINSCOT
WT WEIGHT
ABBREVIATIONS
DOOR TAG
REMOVAL KEY NOTE
ANNOTATION SYMBOLS LEGEND:
WALL / PARTITION TYPE TAG
DETAIL ELEVATION
EXTERIOR ELEVATION
CALLOUT LASSO
XXX
DIMENSION STRING
X'-X"
X-XXXX
X-XXX
X
X
X-XXX
X
X-XXX
X
DETAIL SECTIONBUILDING
SECTION
WALL SECTION
NORTH
NORTH ARROW
1ST FLOOR
100' - 0"
ELEVATION MARKER
DETAIL
NUMBER
SHEET
DETAIL NUMBER
(TYP.)
SHEET (TYP.)
ROOM TAG
ROOM
REVISION IDENTIFICATION
REVISION
REVISION NUMBER
A WINDOW TAG
DOOR (EXISTING)
DOOR
(NEW CONSTRUCTION)
R#
RENOVATION KEY NOTE
EXISTING CONSTRUCTION
(TO BE REMOVED)
XXX
A
WINDOW TAG
WINDOW UNIT
DOOR
DOOR TAG
EXAMPLE:
A101
SIM
A101
SIM
HATCH LEGEND
CONCRETE
(CAST IN PLACE OR PRECAST)
GYPSUM WALL BOARD
CONCRETE MASONRY
EARTH
RIGID INSULATION
BATT INSULATION
WOOD / LUMBER
PLYWOOD
STEEL
UNDERBED MATERIAL
BRICK
ø 5
0"
30" MIN.
M
IN
TURNING RADIUS WHEELCHAIR APPROACH
ADA CLEARANCES:
M
IN
MAX.
6"
M
IN
MIN.
11"
MIN.
8"
MAX.
17" - 25"
KNEE & TOE CLEARANCES
WALL MOUNTED SCONCE
ACCESS HATCH/PANEL
CEILING HEIGHT A.F.F.X' - X"
REFLECTED CEILING PLAN LEGEND
CHANDELIER LIGHT FIXTURE
H HEAT DETECTOR
C CO DETECTOR
1X4 LIGHT FIXTURE
(SHADING DENOTES EMERGENCY LIGHT)
RECESSED CAN LIGHT FIXTURE
OCCUPANCY SENSOR
2x2 ACOUSTICAL CEILING TILE
1X4 T&G BOARD
GYPSUM WALL BOARD
2X4 LIGHT FIXTURE
(SHADING DENOTES EMERGENCY LIGHT)
2X2 LIGHT FIXTURE
(SHADING DENOTES EMERGENCY LIGHT)
EXIT LIGHT
OS
VENEER BEAD BOARD
EXTERIOR WALL PACK LIGHT
RETURN DIFFUSER - SIZES VARIES
NOTE: REFER TO 'FP', 'M', AND 'E' DRAWINGS FOR EXACT FIXTURE /
EQUIPMENT TYPE(S), SIZES AND ADDITIONAL INFORMATION.
2x4 ACOUSTICAL CEILING TILE
PENDANT LIGHT
EXHAUST DIFFUSER - SIZES VARIES
SUPPLY DIFFUSER - SIZES VARIES
S SMOKE DETECTOR
EMERGENCY LIGHT UNIT
COMBO EXIT/EMERGENCY LIGHT UNIT
SPRINKLER HEAD
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
BID DOCUMENTS
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ENGINEER OF RECORD STAMPSUBCONSULTANTS
321 4 5 6 7 8 9 10
DELTA ENGINEERS, ARCHITECTS & SURVEYORS
8401 CONNECTICUT AVE SUITE 350
CHEVY CHASE, MARYLAND 20815
301.718.0080
MORABITO CONSULTANTS, INC.
STRUCTURAL ENGINEERING
952 RIDGEBROOK ROAD, SUITE 1700
SPARKS, MARYLAND 21152
410.467.2377
KOFFEL ASSOCIATES, INC.
8815 CENTRE PARK DR STE 200
COLUMBIA, MD 21045
410.750.2246
VETERAN DESIGN & CONSTRUCTION INC.
5523 RESEARCH PARK DRIVE SUITE 110
BALTIMORE, MARYLAND 21228
443.543.5081
512-23-108RENOVATE C-SEGREGATED
COMPOUNDING AREA FOR
HAZARDOUS COMPOUNDING
VAMC BALTIMORE
F R e v it L o c a ls
\2
.8
.0
V
A M
C B a lt im o re
R e n o v a te C o m p o u n d in g v jd e a n h u n te r@ d e lt a -e a s .c o m
.r v t
/1
/2
:2
:0
P
M
G-002
GENERAL - NOTES, SYMBOLS,
AND ABBREVIATIONS
05/17/2024 EJL JDHRevisions: Date:
jdeanhunter
EJL MD STAMP 11.2.2023
HOOD ROOM C
2C-126
R8
R8
EXISTING TO REMAIN
ENTRY
EXISTING PARTITION & DOOR SHALL
FUNCTION AS CONSTRUCTION BARRIERS
PROVIDE DOORS WITH CLOSER
R11
HOOD
2C-126
R6
EXISTING TO REMAIN
ENTRY
CLEAN ROOM SUITE
BA121L
CHEMO HOOD
BA121K
HOOD ROOM
R1
R3
R3
R3
R2
R4
R3
R5
R7
R7
R1
R1
EXISTING TO REMAIN
ENTRY
R7
R9
TEMPORARY CONSTRUCTION BARRIERS
PROVIDE CONSTRUCTION DOORS WITH CLOSERS
R10
R10
R6
R6
R6
EXISTING TO REMAIN
ENTRY
PROJECT ACTIVITY:
PATIENT RISK GROUP:
PATIENT RISK GROUP:
TYPE C
HIGHEST RISK (Any area caring for immunocompromised patients, Oncology)
CLASS III / IV
ICRA NOTES
DESCRIPTION OF REQUIRED INFECTION PREVENTION PRECAUTIONS BY CLASS
DURING CONSTRUCTION UPON COMPLETION OF CONSTRUCTION
1. OBTAIN INFECTION CONTROL PERMIT BEFORE
CONSTRUCTION BEGINS.
2. ISOLATE HVAC SYSTEM IN AREA WHERE WORK
IS BEING DONE TO PREVENT CONTAMINATION OF
THE DUCT SYSTEM.
3. COMPLETE ALL CRITICAL BARRIERS OR
IMPLEMENT CONTROL CUBE METHOD BEFORE
CONSTRUCTION BEGINS.
4. MAINTAIN NEGATIVE AIR PRESSURE WITHIN
WORK SITE UTILIZING HEPA EQUIPPED AIR
FILTRATION UNITS.
5. REMOVE OR ISOLATE HVAC SYSTEMS IN AREA
WHERE WORK IS BEING PERFORMED.
6. DO NOT REMOVE BARRIERS FROM WORK SITE
UNTIL COMPLETE AND PROJECT IS THOROUGHLY
CLEANED BY EMS.
7. VACUUM WORK WITH HEPA FILTERED VACUUM.
8. WET MOP WITH DISINFECTANT.
9. REMOVE BARRIER MATERIAL CAREFULLY TO
MINIMIZE SPREADING OF DUST AND DEBRIS
ASSOCIATED WITH CONSTRUCTION.
10. CONTAIN CONSTRUCTION WASTE BEFORE
TRANSPORT IN TIGHTLY COVERED CONTAINERS.
11. COVER TRANSPORT RECEPTACLES OR CART
AND TAPE COVERING IN PLACE.
12. SEAL HOLES, PIPES, CONDUITS AND
PENETRATIONS APPROPRIATELY.
13. CONSTRUCT ANTEROOM & REQUIRE ALL
PERSONNEL TO PASS THROUGH THIS ROOM SO
THEY CAN BE VACUUMED USING A HEPA VACUUM
CLEANER BEFORE LEAVING WORKSITE OR THEY
CAN WEAR CLOTH OR PAPER COVERALLS THAT
ARE REMOVED EACH TIME THEY LEAVE THE
WORK SITE.
14. WEAR SHOE COVERS WHEN WITHIN ENTERING
WORK SITE.
1. DO NOT REMOVE BARRIERS FROM WORK AREA
UNTIL COMPLETED PROJECT IS INSPECTED BY
THE OWNER’S SAFETY DEPARTMENT AND
INFECTION PREVENTION COORDINATOR AND
THOROUGHLY CLEANED BY (EMS)
ENVIRONMENTAL MANAGEMENT SERVICES.
2. REMOVE BARRIER MATERIALS CAREFULLY TO
MINIMIZE SPREADING OF DIRT AND DEBRIS
ASSOCIATED WITH CONSTRUCTION.
3. VACUUM WORK AREA WITH HEPA FILTERED
VACUUMS.
4. WET MOP AREA WITH DISINFECTANT.
5. REMOVE ISOLATION OF HVAC SYSTEM IN AREAS
WHERE WORK IS BEING PERFORMED
6. CONTAIN CONSTRUCTION WASTE BEFORE
TRANSPORT IN TIGHTLY COVERED CONTAINERS.
7. COVER TRANSPORT RECEPTACLES OR CARTS.
TAPE COVERING UNLESS SOLID LID
8. VACUUM WORK AREA WITH HEPA FILTERED
VACUUMS.
9. WET MOP AREA WITH DISINFECTANT.
10. INSTALLATION OF STICKY DUST COLLECTION
MAT AT ENTRANCE OF CONTAINED WORK (INSIDE
BARRIER, NOT OUTSIDE)
CLASS: CLASS IV
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
BID DOCUMENTS
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ENGINEER OF RECORD STAMPSUBCONSULTANTS
321 4 5 6 7 8 9 10
DELTA ENGINEERS, ARCHITECTS & SURVEYORS
8401 CONNECTICUT AVE SUITE 350
CHEVY CHASE, MARYLAND 20815
301.718.0080
MORABITO CONSULTANTS, INC.
STRUCTURAL ENGINEERING
952 RIDGEBROOK ROAD, SUITE 1700
SPARKS, MARYLAND 21152
410.467.2377
KOFFEL ASSOCIATES, INC.
8815 CENTRE PARK DR STE 200
COLUMBIA, MD 21045
410.750.2246
VETERAN DESIGN & CONSTRUCTION INC.
5523 RESEARCH PARK DRIVE SUITE 110
BALTIMORE, MARYLAND 21228
443.543.5081
512-23-108RENOVATE C-SEGREGATED
COMPOUNDING AREA FOR
HAZARDOUS COMPOUNDING
VAMC BALTIMORE
AB
DC
NORTH
KEYPLAN
F R e v it L o c a ls
\2
.8
.0
V
A M
C B a lt im o re
R e n o v a te C o m p o u n d in g v jd e a n h u n te r@ d e lt a -e a s .c o m
.r v t
/1
/2
:2
:0
P
M
AD-101
ARCHITECTURAL - FLOOR PLANS -
DEMOLITION
05/17/2024 EJL JDH
GENERAL REMOVAL NOTES
A. ITEMS DESIGNATED ON PLAN BY DASHED LINE ARE EXISTING ELEMENTS TO BE
REMOVED. REFER TO OTHER TRADE DRAWINGS FOR OTHER REMOVALS, INCLUDING
MODIFICATIONS THAT MAY EXTEND BEYOND AREAS SHOWN.
B. FOR DURATION OF PROJECT, EXISTING CONSTRUCTION AND/OR EQUIPMENT TO
REMAIN FROM DAMAGE OR CONSTRUCTION ACTIVITIES. WHERE CONSTRUCTION
ACTIVITIES RESULT IN DAMAGE TO EXISTING CONSTRUCTION TO BE RETAINED,
REPLACE/REPAIR EXISTING CONSTRUCTION TO RETURN IT TO ITS ORIGINAL
CONDITION. WHERE REMOVAL OF EXISTING CONSTRUCTION, PIPING, DUCTWORK,
AND OTHER ITEMS CREATES OPENINGS IN WALLS, FLOORS OR CEILINGS, PATCH
OPENINGS IMMEDIATELY WITH SAME MATERIALS AS ADJACENT CONSTRUCTION
AND/OR TO MAINTAIN REQUIRED FIRE RATING. ANY WORK AFFECTING THE WALL
MUST BE PAINTED TO MATCH EXISTING COLOR AND LAYERS. PROVIDE TWO COASTS
OF PAINT AND TWO COATS OF PRIMER MIN.
C. PROVIDE FULL HEIGHT TEMPORARY CONSTRUCTION BARRIERS WHERE REQUIRED TO
PREVENT DUST POLLUTION OF SURROUNDING OCCUPIED AREAS. CONSTRUCTION
BARRIERS ARE REQUIRED PER THE ICRA PERMIT. SEAL AIR-TIGHT. PARTITIONS MUST
BE INSTALLED IN ACCORDANCE WITH FIRE PROTECTION AND EGRESS
REQUIREMENTS. MAINTAIN MEANS OF EGRESS ACCESS TO EXITS DURING
CONSTRUCTION.
D. TAKE PROPER MEASURES TO PREVENT DUST MIGRATION TO AREAS OUTSIDE THE
CONSTRUCTION AREA BY CLOSING ALL OPENINGS IN DUCTS, WALLS, FLOORS AND
CEILINGS. PROVIDE CONTINUOUS EXHAUST TO EXTERIOR TO MAINTAIN NEGATIVE
PRESSURE IN CONSTRUCTION AREA.
E. COORDINATE WITH OWNER FOR EQUIPMENT TO BE SALVAGED AND RETURNED TO
OWNER. THE OWNER WILL RETAIN ALL SALVAGE THAT IS OF VALUE AS DESIGNATED
BY THE USER OR BUILDING ENGINEER. REMOVE FROM THE BUILDING AND DISPOSE
OF IN A LAWFUL MANNER ALL DEBRIS AND/OR ITEMS NOT RETAINED BY OWNER.
F. ADHESIVE MATS SHALL BE PLACED INSIDE CONSTRUCTION AREA ONLY TO REDUCE
TRIP HAZARD PER INFECTION CONTROL PROCEDURE. MATS ARE TO BE REPLACED
WITH NEW SHEET ON AN AS-NEEDED BASIS, BUT AT A MINIMUM OF DAILY BASIS.
G. COORDINATE WITH OTHER TRADE DRAWINGS FOR REMOVAL WORK, AS REQUIRED.
REMOVAL KEY NOTES
R1 REMOVE EXISTING PARTITION. PATCH AND REPAIR AS NEEDED.
R2 REMOVE EXISTING CASEWORK/CABINETS. PATCH AND REPAIR AS NEEDED.
R3 REMOVE EXISTING EQUIPMENT. COORDINATE WITH GC AND OWNER
R4 REMOVE EXISTING SINK AND CABINET.
R5 REMOVE EXISTING COUNTERTOP, PREP AREA TO RECEIVE NEW COUNTERTOP.
R6 REMOVE EXISTING CEILING. PREP AREA TO RECEIVE NEW LIGHTING AND CEILING.
R7 REMOVE EXISTING DOOR AND FRAME
R8 REMOVE EXISTING FURNITURE. COORDINATE WITH OWNER.
R9 REMOVE EXISTING EYEWASH
R10 REMOVE EXISTING ADA ACCESS PUSH BUTTON. V.I.F. LOCATION
R11 REMOVE EXISTING WINDOW PANEL & SUBFRAME, PREPARE AREA FOR PANEL
INFILL & LOUVER PENETRATION
SCALE: 1/4" = 1'-0"AD-101
3 SECOND FLOOR- REMOVAL PLAN
SCALE: 1/4" = 1'-0"AD-101
4 SECOND FLOOR - REMOVAL RCP
SCALE: 1/4" = 1'-0"AD-101
1 BASEMENT-REMOVAL PLAN
SCALE: 1/4" = 1'-0"AD-101
2 BASEMENT-REMOVAL RCP
0'
SCALE: 1/4" = 1'-0"
1' 2' 8'4'
Revisions: Date:
SS
MALE
TOIL.
SUPERV.
OFFICE
S-9
STAIR #5
DIETETIC CLEAN
CART SENDING
TERMINAL
ELEC.
CLO
H.A.C.
AIRLOCK
STORAGE
CORRIDOR
CORRIDOR
FEC
FEC
STERILIZE
GOWN
AIRLOCK
CORRIDOR
PROCEDURAL
LAB
ANIMAL
LAB
ANIMAL
WARD
CAGE
WASHING
CONTAINMENT
ANIMAL WARD
CONTAINMENT
ANIMAL WARD
CONTAINMENT
ANIMAL WARD
HAZARD
ANIMAL WARDHAZARD
ANIMAL WARD
HAZARD
ANIMAL
WARD
HAZARD
ANIMAL
WARD
HAZARD
ANIMAL
WARD
BARRIER
ANIMAL WARD
BARRIER
ANIMAL WARD
BARRIER
ANIMAL WARD
BARRIER
ANIMAL WARD
SHOWER
CORRIDOR
AIRLOCK AIRLOCK
REPRO.
FEMALE
TOIL.
P.T.S.
UP
8K
SOILED
LINEN
GREASE
INTERCEPTOR
HAC
SUBSISTENCE
STORAGE
SILVER
COLLECTION
STOR.
KEEPER
VEST.
LOUNGE
OFFICE
BB103
BB146
BB147
BB118
BB120
BB123
BB124
BB122
BB102
BB100d
BB100c
BB100e
BB100b
CB-26
CB-25
CB-22
CB-23
BB121
CB-15
BB106a
BB106
BB106b BB109a
BB109
BB111BB108
BB112
BB117
BB119
BB107
BB116
CB-12
CB-13
H12B2-72
BLDG. MGMT.
SEC'Y/WAITING
BLDG. MGMT.
SUPERV. OFFICE
BLDG. MGMT.
SUPERV. OFFICE
BLDG. MGMT.
CHIEF OFFICE
BLDG. MGMT.
FEMALE LKR'S
BLDG. MGMT.
MALE LKR'S
BLDG. MGMT.
STAFF LOUNGE
BLDG. MGMT.
STORAGE
DIET. STAFF
DINING/TRAINING
HAC
CLEAN LINEN
SORTING/STORAGE
MALE
TOIL.
DIETETIC FOOD
PROCESSING
OFFICE
SUPERV.
OFFICE
TELETYPE
TRAY
MAKE UP
S-12
S-9
STAIR #5
DIETETIC CLEAN
CART SENDING
TERMINAL
P-4
H.A.C.
ELEC.
CLO
H.A.C.
STORAGE
FEC
FEC
ADMIN. AREA
BULK STORAGESOLUTION
STORAGE
SEC'Y
WAITING
ASS'T
CHIEF
CART
STOR.
AIRLOCK
PROCEDURAL
LAB
CONTAINMENT
ANIMAL WARD
HAZARD
ANIMAL WARD
HAZARD
ANIMAL
WARD
BARRIER
ANIMAL WARD
AIRLOCK
TELE.
SWITCH BD.
REPRO.
P.T.S.
PICKING
AREA
INPATIENT
PHARMACY
DRUG INFORMATION
METHADONE PKG./
VAULT
LOUNGE/
LOCKERS
OFFICE OFFICE CLERK
CLERK
SUPERVISOR
OFFICE
SUPERVISOR
OFFICE
CART
STORAGE
FEMALE
TOIL.
P.T.S.
CORRIDOR
W/C
M.TOILET
W/C
F.TOILET
UP
CHIEF
RECEIV'G.
BB114
BA106a BA107
BA108
BA121a
BA103
BA119a
BA119b
BA119c
BA118b
BA118d
BA118e
BA120h
BA120g
BA120i
BA121h
BA121i
BA121g
BA121j
BA121f
BA120
BA121c
BA121b
BA121
CB-7
CB-5
BA104
BA105e
BA105a
BA105o
BA105n
BA105
BA109a
BA110
BA109
CB-6
BA101
BB101
BB115
BA121d
BB109b
BB111
BB113
CB-24
BA106
BA120b
BA121e
BA120j
BA120d BA120f
BA120eBA120cBA120a
BA102
BA117a
CB-8
BB110
BB109
BB116
CB-12
UP
142 SF
PHARMACY
BA121K
175 SF
ANTEROOM
BA121L
99 SF
HOOD ROOM A
BA121O
100 SF
HOOD ROOM B
BA121P
EXISTING TO REMAIN
LIFE SAFETY LEGEND
1 HOUR FIRE RESISTANCE RATING
2 HOUR FIRE RESISTANCE RATING
PRIMARY EGRESS PATH
SECONDARY EGRESS PATH
MRP MOST REMOTE POINT OF EGRESS
ACCESS
EXIT DISCHARGE
TD = XX' - XX" TRAVEL DISTANCE TO EXIT
FIRE EXTINGUISHER
FIRE EXTINGUISHER CABINET
SMOKE BARRIER (1HR RATED,
UNLESS OTHERWISE SHOWN)
HOOD ROOM C
2C-126
STAIR #1
HEMODIALYSIS
2C-127
EXAM ROOM
2C-127b
EXAM ROOM
2C-127c
NURSE STATION
C2-35
DIETETICS
2C-127E
EXAM ROOM
2C-127F
CORRIDOR
C2-28
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
BID DOCUMENTS
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ENGINEER OF RECORD STAMPSUBCONSULTANTS
321 4 5 6 7 8 9 10
DELTA ENGINEERS, ARCHITECTS & SURVEYORS
8401 CONNECTICUT AVE SUITE 350
CHEVY CHASE, MARYLAND 20815
301.718.0080
MORABITO CONSULTANTS, INC.
STRUCTURAL ENGINEERING
952 RIDGEBROOK ROAD, SUITE 1700
SPARKS, MARYLAND 21152
410.467.2377
KOFFEL ASSOCIATES, INC.
8815 CENTRE PARK DR STE 200
COLUMBIA, MD 21045
410.750.2246
VETERAN DESIGN & CONSTRUCTION INC.
5523 RESEARCH PARK DRIVE SUITE 110
BALTIMORE, MARYLAND 21228
443.543.5081
512-23-108RENOVATE C-SEGREGATED
COMPOUNDING AREA FOR
HAZARDOUS COMPOUNDING
VAMC BALTIMORE
AB
DC
NORTH
KEYPLAN
F R e v it L o c a ls
\2
.8
.0
V
A M
C B a lt im o re
R e n o v a te C o m p o u n d in g v jd e a n h u n te r@ d e lt a -e a s .c o m
.r v t
/1
/2
:2
:0
P
M
AL-101
LIFE SAFETY PLAN
05/17/2024 EJL JDH
SCALE: 3/32" = 1'-0"AL-101
1 ARCHITECTURAL - FLOOR PLANS - PARTIAL BASEMENT LIFE SAFETY PLAN
SCALE: 3/32" = 1'-0"AL-101
2 ARCHITECTURAL - FLOOR PLANS - PARTIAL 2ND FLOOR LIFE SAFETY PLAN
0'
SCALE: 3/32" = 1'-0"
5'-4" 21'-4"10'-8"
NOTES:
1. MODIFY EXISTING PARTITIONS TO MEET 1 HOUR FIRE RATING.
Revisions: Date:
18' - 11"
AS-201
AS-201
AS-201
AS-201
142 SF
PHARMACY
BA121K
175 SF
ANTEROOM
BA121L
99 SF
HOOD ROOM A
BA121O
100 SF
HOOD ROOM B
BA121P
EXISTING TO REMAIN
ENTRY
9' - 3" 9' - 3"
103 104
A1.1
A1.1
A1.1
1"6'
TEMPORARY
CONSTRUCTION BARRIERS
PROVIDE CONSTRUCTION
DOORS WITH CLOSERS
B
B
9 10
A1.3
1' - 11"
3'
/2
1'
/2
B1.1
2'
2' - 7 1/2"
1'
/2
1'
/2
130 SF
HOOD ROOM C
2C-126
AS-201
EXISTING TO REMAIN
ENTRY
TEMPORARY CONSTRUCTION BARRIERS
PROVIDE CONSTRUCTION DOORS WITH
CLOSERS
A1.3
A1.3
1' - 9"
ALIGN
1'
B1.1
6 1/2"
AS-501
AS-501
6 6
ENTRY
8' - 0"
8' - 0"
8' - 0" 8' - 0"
ANTEROOM
BA121L
PHARMACY
BA121K
HOOD ROOM A
BA121O
HOOD ROOM B
BA121P
EXISTING TO REMAIN
EXISTING TO REMAIN ENTRY
HOOD ROOM C
2C-126 8' - 0"
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
BID DOCUMENTS
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ENGINEER OF RECORD STAMPSUBCONSULTANTS
321 4 5 6 7 8 9 10
DELTA ENGINEERS, ARCHITECTS & SURVEYORS
8401 CONNECTICUT AVE SUITE 350
CHEVY CHASE, MARYLAND 20815
301.718.0080
MORABITO CONSULTANTS, INC.
STRUCTURAL ENGINEERING
952 RIDGEBROOK ROAD, SUITE 1700
SPARKS, MARYLAND 21152
410.467.2377
KOFFEL ASSOCIATES, INC.
8815 CENTRE PARK DR STE 200
COLUMBIA, MD 21045
410.750.2246
VETERAN DESIGN & CONSTRUCTION INC.
5523 RESEARCH PARK DRIVE SUITE 110
BALTIMORE, MARYLAND 21228
443.543.5081
512-23-108RENOVATE C-SEGREGATED
COMPOUNDING AREA FOR
HAZARDOUS COMPOUNDING
VAMC BALTIMORE
AB
DC
NORTH
KEYPLAN
F R e v it L o c a ls
\2
.8
.0
V
A M
C B a lt im o re
R e n o v a te C o m p o u n d in g v jd e a n h u n te r@ d e lt a -e a s .c o m
.r v t
/1
/2
:2
:1
P
M
AS-101
ARCHITECTURAL - FLOOR PLANS -
NEW WORK
05/17/2024 EJL JDH
SCALE: 1/4" = 1'-0"AS-101
1 BASEMENT-NEW WORK PLAN
SCALE: 1/4" = 1'-0"AS-101
3 SECOND FLOOR- NEW WORK PLAN
SCALE: 1/4" = 1'-0"AS-101
2 BASEMENT-NEW WORK RCP
SCALE: 1/4" = 1'-0"AS-101
4 SECOND FLOOR - NEW WORK RCP
GENERAL ARCHITECTURAL NOTES
A. VERIFY ALL DIMENSIONS AND EXISTING CONDITIONS. NOTIFY THE ARCHITECT OF
DISCREPANCIES PRIOR TO COMMENCING WORK. EXISTING CONDITIONS THAT WOULD
AFFECT THE EXECUTION OF THE WORK MUST BE BROUGHT TO THE ATTENTION OF THE
ARCHITECT PRIOR TO COMMENCING THE WORK.
B. DIMENSIONS GIVEN ON PLANS ARE FROM FINISHED FACE TO FINISHED FACE UNLESS
OTHERWISE NOTED. DIMENSIONS ARE NOT ADJUSTABLE WITHOUT THE APPROVAL OF
THE ARCHITECT UNLESS OTHERWISE NOTED.
C. PROVIDE BLOCKING IN WALLS AS REQUIRED TO SUPPORT WALL MOUNTED ITEMS.
LOCATE EQUIPMENT AND COORDINATE BLOCKING LOCATIONS IN FIELD.
D. PROVIDE PROTECTION OF EXISTING FINISHES AND/OR MATERIALS. RESTORE TO
ORIGINAL CONDITIONS AREAS OR FINISHES DAMAGED BY THE WORK, AT THE EXPENSE
OF THE CONTRACTOR. REMOVE MEANS OF PROTECTION AT THE END OF THE
PROJECT.
E. ALL SCRATCHES, DENTS, CRACKS, HOLES, OPENINGS, IRREGULARITIES AND/OR
DEFECTS IN BOTH EXISTING AND NEW CONSTRUCTION SURFACES ARE TO BE
PATCHED TO PROVIDE A UNIFORM AND SMOOTH FINISHED SURFACE. CLEAN AND SAND
SMOOTH SURFACES BEFORE APPLYING FINISH MATERIALS.
F. REMOVE ALL EXCESS BUILD-UP OF EXISTING AND/OR NEW WALL AND PAINT
MATERIALS FROM ALL NEW AND EXISTING WALL SURFACES. CLEAN AND FINISH SAND
SMOOTH TO PROVIDE A UNIFORM AND SMOOTH WALL SURFACE READY FOR THE
APPLICATION OF FINISH MATERIALS.
G. DIMENSIONS LOCATING DOORS OR INTERIOR WINDOWS ARE TO OUTSIDE EDGE OF
FRAME UNLESS NOTED OTHERWISE. REFER TO DOOR & WINDOW SHEETS FOR FRAME
TYPE, SIZE AND DETAILS.
H. REFER TO CIVIL, STRUCTURAL, FIRE PROTECTION, PLUMBING, MECHANICAL, AND
ELECTRICAL DRAWINGS FOR ADDITIONAL INFORMATION.
I. NEW WORK SHALL BE COMPLIANT WITH NFPA 45.
RENOVATION KEY NOTES
1 INSTALL PARTITION AND DOOR
2 INSTALL PASS-THROUGH WINDOW
3 INSTALL EQUIPMENT. SEE EQUIPMENT SCHEDULE.
4 INSTALL MOBILE WORKSTATION SYSTEM.
5 INSTALL MOBILE BASE CABINET.
6 INSTALL GYP BOARD CEILING & LIGHTING FIXTURES.
7 INSTALL DOOR W/ WITH CLOSER AT EXISTING PARTITION
8 INSTALL WALL MOUNTED SINK. SEE PLUMBING SCHEDULE
9 INSTALL STICKY DUST COLLECTION MAT
10 INSTALL ADA ACCESS PUSH BUTTON
11 INSTALL FIRE SHUTTER @ PASS THROUGH WINDOW. SEE DETAILS 5/6/7-AS-501
12 INSTALL CARD READER
NOTE: REFER TO ELEC. DRAWINGS FOR LIGHTING LAYOUT.
NOTE: REFER TO ELEC. DRAWINGS FOR LIGHTING LAYOUT.
0'
SCALE: 1/4" = 1'-0"
1' 2' 8'4'
Revisions: Date:
142 SF
PHARMACY
BA121K
175 SF
ANTEROOM
BA121L
99 SF
HOOD ROOM A
BA121O
100 SF
HOOD ROOM B
BA121P
EXISTING TO REMAIN
ENTRY
PNT-3
PNT-3
PNT-3
PNT-3
PNT-3
130 SF
HOOD ROOM C
2C-126
EXISTING TO REMAIN
ENTRY
PNT-3
FLOOR FINISH LEGEND
RF-1
142 SF
PHARMACY
BA121K
175 SF
ANTEROOM
BA121L
99 SF
HOOD ROOM A
BA121O
100 SF
HOOD ROOM B
BA121P
EXISTING TO REMAIN
ENTRY
1 2
130 SF
HOOD ROOM C
2C-126
EXISTING TO REMAIN
ENTRY
2 4
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
BID DOCUMENTS
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ENGINEER OF RECORD STAMPSUBCONSULTANTS
321 4 5 6 7 8 9 10
DELTA ENGINEERS, ARCHITECTS & SURVEYORS
8401 CONNECTICUT AVE SUITE 350
CHEVY CHASE, MARYLAND 20815
301.718.0080
MORABITO CONSULTANTS, INC.
STRUCTURAL ENGINEERING
952 RIDGEBROOK ROAD, SUITE 1700
SPARKS, MARYLAND 21152
410.467.2377
KOFFEL ASSOCIATES, INC.
8815 CENTRE PARK DR STE 200
COLUMBIA, MD 21045
410.750.2246
VETERAN DESIGN & CONSTRUCTION INC.
5523 RESEARCH PARK DRIVE SUITE 110
BALTIMORE, MARYLAND 21228
443.543.5081
512-23-108RENOVATE C-SEGREGATED
COMPOUNDING AREA FOR
HAZARDOUS COMPOUNDING
VAMC BALTIMORE
AB
DC
NORTH
KEYPLAN
F R e v it L o c a ls
\2
.8
.0
V
A M
C B a lt im o re
R e n o v a te C o m p o u n d in g v jd e a n h u n te r@ d e lt a -e a s .c o m
.r v t
/1
/2
:2
:1
P
M
AS-102
ARCHITECTURAL - FINISH &
EQUIPMENT PLAN
05/17/2024 EJL JDH
SCALE: 1/4" = 1'-0"AS-102
1 BASEMENT-FINISH PLAN
SCALE: 1/4" = 1'-0"AS-102
2 SECOND FLOOR- FINISH PLAN
ROOM FINISH SCHEDULE LEGEND
MATERIAL /
FINISH NAME DESCRIPTION
ACT ACOUSTICAL CEILING TILE
CFT CERAMIC FLOOR TILE
CMU CONCRETE MASONRY UNITS
CONC. CONCRETE
CWT CERAMIC WALL TILE
EPY EPOXY
EX. EXISTING
GWB GYPSUM WALL BOARD
LVT LUXURY VINYL TILE
PNT PAINT
RF RUBBER FLOORING
ROOM FINISH SCHEDULE
ROOM
NUMBER
ROOM NAME
FLOOR
BASE
WALLS CEILING
COMMENTS
FINISH FINISH FINISH
2C-126 HOOD ROOM C RF-1 RF INTEGRAL PNT-1/PNT-2 GYP
BA121K PHARMACY RF-1 RF INTEGRAL PNT-1/PNT-2 GYP
BA121L ANTEROOM RF-1 RF INTEGRAL PNT-1/PNT-2 GYP
BA121O HOOD ROOM A RF-1 RF INTEGRAL PNT-1/PNT-2 GYP
BA121P HOOD ROOM B RF-1 RF INTEGRAL PNT-1/PNT-2 GYP
NOTES:
1. WALLS MUST BE COVERED WITH EPOXY PAINT OR HEAVY GAUGE POLYMER.
2. WALLS ARE PNT-2 UNLESS NOTED OTHERWISE.
3. SEE SPEC SECTION 090600 FOR PNT SELECTION.
SCALE: 1/4" = 1'-0"AS-102
3 BASEMENT-EQUIPMENT PLAN
SCALE: 1/4" = 1'-0"AS-102
4 SECOND FLOOR- EQUIPMENT PLAN
EQUIPMENT SCHEDULE
EQUIPMENT NUMBER EQUIPMENT NAME Manufacturer Model FURNISH/INSTALL COMMENTS
1 EDGEGARD HOOD BAKER EG-5252 GF/GF
2 CHEMO SHIELD BAKER CS600 GF/GF
3 PHARMACY REFRIGERATOR DOUBLE DOOR SO-LOW DH4-49SD
4 PHARMACY REFRIGERATOR SINGLE DOOR SO-LOW DH4-27SD GF/GF
5 MOBILE WORKSTATION KEWAUNEE FE30M8402
GF/GF
GC/GC
0'
SCALE: 1/4" = 1'-0"
1' 2' 8'4'
Revisions: Date:
PASSTHROUGH
WINDOW
MOBILE CABINET, TYP.
MOBILE
WORKSTATION
SLIDING
DOOR
FINISH
PANEL
AS-501
2' - 0"
2'
0"
3'
STAINLESS STEEL
COUNTERTOP
BASE AS
SCHED.6' - 0"
MOBILE BASE CABINET, TYP.
STAINLESS STEEL COUNTERTOP
MOBILE WORKSTATION
2'
0"
BASE AS SCHED. 2'
2' - 0"
6' - 0"
REFRIGERATOR UNIT
SLIDING DOOR
BASE AS SCHED.
3'
2'
PUSH BUTTON
7'
SHUTTER DOOR
1'
3'
PASSTHROUGH WINDOW
BASE AS SCHED.
1' - 1"
4'
B B
AS-501
MOBILE BASE CABINET, TYP.
STAINLESS STEEL COUNTERTOP
MOBILE WORKSTATION
6' - 0"
2' - 0"
2'
BASE AS SCHED.
SOAP DISPENSER
3'
WALL
MOUNTED
SCRUB SINK
3' - 0" 7 1/2"
2'
0"
MOBILE CABINET, TYP.
MOBILE
WORKSTATION
PASS THROUGH
WINDOW
AS-501
3'
BASE AS SCHED.
2' - 0"
2'
6' - 0"
CABINET HOOD
BASE AS SCHED.
BASE CABINET, TYP.
S.S. COUNTERTOP W/ BACKSPLASH
2'
0"
PASSTHROUGH
WINDOW
BASE AS SCHED.
1'
1' - 0" 1' - 3 1/2"
3'
/2
B
AS-501
NEW MECHANICAL
HOOD
BASE AS
SCHED.
REFRIGERATOR PASSTHROUGH WINDOW
BASE AS SCHED.3'
/2
1'
2' - 4"
B
AS-501
CABINET HOOD
REFRIGERATOR
BASE AS SCHED.
WALL MOUNTED SINK
BASE AS SCHED.
AUTOMATIC DOOR PUSH BUTTON
2'
0"
3' - 0"
MOBILE BASE CABINET, TYP.
STAINLESS STEEL COUNTERTOP
MOBILE SHELVING UNIT
BASE AS SCHED.
8' - 0"
2' - 0"
2'
2'
0"
CARD READER
BASE AS SCHED.
MOBILE BASE CABINET, TYP.
STAINLESS STEEL COUNTERTOP
MOBILE WORKSTATION
2'
0"
2'
2' - 0"
CABINET HOOD
BASE AS SCHED.
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
BID DOCUMENTS
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ENGINEER OF RECORD STAMPSUBCONSULTANTS
321 4 5 6 7 8 9 10
DELTA ENGINEERS, ARCHITECTS & SURVEYORS
8401 CONNECTICUT AVE SUITE 350
CHEVY CHASE, MARYLAND 20815
301.718.0080
MORABITO CONSULTANTS, INC.
STRUCTURAL ENGINEERING
952 RIDGEBROOK ROAD, SUITE 1700
SPARKS, MARYLAND 21152
410.467.2377
KOFFEL ASSOCIATES, INC.
8815 CENTRE PARK DR STE 200
COLUMBIA, MD 21045
410.750.2246
VETERAN DESIGN & CONSTRUCTION INC.
5523 RESEARCH PARK DRIVE SUITE 110
BALTIMORE, MARYLAND 21228
443.543.5081
512-23-108RENOVATE C-SEGREGATED
COMPOUNDING AREA FOR
HAZARDOUS COMPOUNDING
VAMC BALTIMORE
F R e v it L o c a ls
\2
.8
.0
V
A M
C B a lt im o re
R e n o v a te C o m p o u n d in g v jd e a n h u n te r@ d e lt a -e a s .c o m
.r v t
/1
/2
:2
:1
P
M
AS-201
ARCHITECTURAL - ELEVATIONS
05/17/2024 EJL JDH
SCALE: 3/8" = 1'-0"AS-201
1 PHARMACY- ELEVATION 1
SCALE: 3/8" = 1'-0"AS-201
2 PHARMACY - ELEVATION 2
SCALE: 3/8" = 1'-0"AS-201
3 PHARMACY -ELEVATION 3
SCALE: 3/8" = 1'-0"AS-201
4 ANTEROOM- ELEVATION 1
SCALE: 3/8" = 1'-0"AS-201
5 ANTEROOM - ELEVATION 2
SCALE: 3/8" = 1'-0"AS-201
6 ANTEROOM - ELEVATION 3
SCALE: 3/8" = 1'-0"AS-201
8 HOOD ROOM A - ELEVATION 2
SCALE: 3/8" = 1'-0"AS-201
9 HOOD ROOM A - ELEVATION 3
SCALE: 3/8" = 1'-0"AS-201
11 HOOD ROOM B - ELEVATION 2
SCALE: 3/8" = 1'-0"AS-201
12 HOOD ROOM B - ELEVATION 3
SCALE: 3/8" = 1'-0"AS-201
13 HOOD ROOM C - ELEVATION 1
SCALE: 3/8" = 1'-0"AS-201
14 HOOD ROOM C - ELEVATION 2
SCALE: 3/8" = 1'-0"AS-201
15 HOOD ROOM C - ELEVATION 3
SCALE: 3/8" = 1'-0"AS-201
10 HOOD ROOM B - ELEVATION 1
0'
SCALE: 3/8" = 1'-0"
1'-4" 5'-4"2'-8"
SCALE: 3/8" = 1'-0"AS-201
7 HOOD ROOM A - ELEVATION 1
Revisions: Date:
LOUVER WIDTH
LO
U
V E
R H
E
IG
H T
LOUVER
FRAME
LOUVER
BLADES
SEE MECHANICAL FOR LOUVER TYPES
LOUVER FRAME
EXISTING WALL
INSECT SCREEN
WALL ANGLE FRAME
SEALANT @
PERIMETER, TYP
NOTES:
1. LOUVER/DAMPER ASSEMBLIES TO BE ASSEMBLED
AT LOUVER MANUFACTURER FACTORY.
2. CLIP ANGLES AND EXTENDED SILL TO BE PROVIDED
BY LOUVER MANUFACTURER.
3. INSTALLATION OF LOUVER TO BE IN ACCORDANCE
WITH LOUVER MANUFACTURER'S RECOMMENDATIONS.
EXISTING
EXTERIOR WALL
BIRD SCREEN
CLIP ANGLES
STORM BLADE
LOUVER
LOUVER ASSEMBLY
FINISH TO MATCH WALL
EXTERIOR
BACKER ROD & SEALANT
HEAD FLASHING, CARRY OVER
LOUVER ASSEMBLY AND TURN UP
AT ANGLE CLIPS
INTERIOREXTERIOR
SILL FLASHING, CARRY UNDER &
BEHIND LOUVER ASSEMBLY
3-SIDED SQUARE
HOOD
PAD LOCKABLE SLIDE BOLT
STOPPERS
ASTRAGAL
5 1/2"
CULUS CLASSIFIED TO: ANSI/UL 10B AND
CAN/ULC-S104 ROLLING COUNTER FIRE DOOR
#22 GA. INTERLOCKING SLATS
1 HOUR RATED
ALARMGARD CRANK OPERATION
MINIMUM #16 GA STEEL STUDS
REQUIRED AT JAMB AND SILL
#14 PHILIPS PAN HEAD TAPPING SCREWS
3" LONG W/ STEEL & FIBER WASHERS. 18"
ON CENTER MAXIMUM
1/2"
2"
STEEL BRACKET PLATE
ABOVE
2"
2"
OPENING WIDTH
5"
#12 GA GUIDE
DISTANCE BETWEEN GUIDES
TOP HOOD BEAD
TURNED UP11"11 3/4" ±
8 3/4" ±
4" B
O T
T O
M O
F D
O O
R O
P E
N
IN
G T
O F
.F
REMOVABLE HAND
CRANK
CLEAR SEALANT
PARTITION AS SCHED.
PASS-THROUGH WINDOW
ASSEMBLY
8 PC. UNIVERSAL
STAINLESS STEEL
MOUNTING FRAME
SET
1" 2' - 0" 1"
MECHANICAL
INTERLOCK, NON-
LOCKING, STAINLESS
STEEL T-HANDLES
OVER CENTER
COMPRESSION LATCH,
STAINLESS STEEL
PASS THROUGH
WINDOW ASSEMBLY
1 1/2"
8 PC. UNIVERSAL
STAINLESS STEEL
MOUNTING FRAME
SET
BASE CABINET W/SSM
COUNTERTOP. SEE
DWG 4/A-601
4"
1 1/2" 2 1/2"
MECHANICAL
INTERLOCK, NON-
LOCKING, STAINLESS
STEEL T-HANDLES
OVER CENTER
COMPRESSION LATCH,
STAINLESS STEEL
1" 1' - 0" 1"
1/
2"
PASS THROUGH
WINDOW ASSEMBLY
EXISTING OUTER WINDOW
FRAME
EXHAUST
LOUVER. SEE
MECH DWG.
EXISTING
STRUCTURE.
LOUVER ASSEMBLY
EXISTING STRUCTURE
5/8" GYP BD.
3" BATT INSULATION
SEALANT
LOUVER FRAME
INSULATED BLANK
OFF PANEL
EXISTING WINDOW
OUTER FRAME
3 5/8" METAL STUD
ALIGN TO EDGE OF SILL
EXISTING OUTER WINDOW
FRAME
EXHAUST
LOUVER. SEE
MECH DWG.
EXISTING WINDOW
ASSEMBLY
LOUVER ASSEMBLY
EXISTING STRUCTURE
5/8" GYP BD.
3" BATT INSULATION
LOUVER FRAME
INSULATED BLANK
OFF PANEL
EXISTING WINDOW
OUTER FRAME
3 5/8" METAL STUD
EXISTING
STRUCTURE
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
BID DOCUMENTS
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ENGINEER OF RECORD STAMPSUBCONSULTANTS
321 4 5 6 7 8 9 10
DELTA ENGINEERS, ARCHITECTS & SURVEYORS
8401 CONNECTICUT AVE SUITE 350
CHEVY CHASE, MARYLAND 20815
301.718.0080
MORABITO CONSULTANTS, INC.
STRUCTURAL ENGINEERING
952 RIDGEBROOK ROAD, SUITE 1700
SPARKS, MARYLAND 21152
410.467.2377
KOFFEL ASSOCIATES, INC.
8815 CENTRE PARK DR STE 200
COLUMBIA, MD 21045
410.750.2246
VETERAN DESIGN & CONSTRUCTION INC.
5523 RESEARCH PARK DRIVE SUITE 110
BALTIMORE, MARYLAND 21228
443.543.5081
512-23-108RENOVATE C-SEGREGATED
COMPOUNDING AREA FOR
HAZARDOUS COMPOUNDING
VAMC BALTIMORE
F R e v it L o c a ls
\2
.8
.0
V
A M
C B a lt im o re
R e n o v a te C o m p o u n d in g v jd e a n h u n te r@ d e lt a -e a s .c o m
.r v t
/1
/2
:2
:2
P
M
AS-501
DETAILS
05/17/2024 EJL JDH
SCALE: 1 1/2" = 1'-0"AS-501
2 LOUVER ELEVATION
SCALE: 1 1/2" = 1'-0"AS-501
3 LOUVER JAMB DETAIL TYP.
SCALE: 1 1/2" = 1'-0"AS-501
1 LOUVER, TYP
SCALE: 1 1/2" = 1'-0"AS-501
7 FIRE SHUTTER - ELEVATION DETAIL
SCALE: 3" = 1'-0"AS-501
9 FIRE SHUTTER - PLAN DETAIL
SCALE: 1 1/2" = 1'-0"AS-501
8 FIRE SHUTTER - SECTION DETAIL
SCALE: 1 1/2" = 1'-0"AS-501
6 PASS THROUGH WINDOW @ PHARMACY
SCALE: 1 1/2" = 1'-0"AS-501
10 PASSTHROUGH WINDOW
1. SEE MECH DWG FOR LOUVER LOCATIONS.
NOTES:
0'
SCALE: 1-1/2" = 1'-0"
2" 4" 1'-4"8"
SCALE: 1 1/2" = 1'-0"AS-501
4 LOUVER @ WINDOW SECTION DETAIL
SCALE: 1 1/2" = 1'-0"AS-501
5 LOUVER @ WINDOW JAMB DETAIL
Revisions: Date:
2" 2"
F-1
S E
E S
C H
E D
U
LE
2"
SCHEDULE
SEE
FRAME TYPE LEGEND
DOUBLE DOOR
2" 2"SEE SCHEDULE
G-1 S
E E
S C
H E
D U
LE
2"
A
S E
E S
C H
E D
U
LE
SCHEDULE
SEE
FLUSH MOUNTED
DOOR
DOOR TYPE LEGEND
FLUSH MOUNTED SLIDING
DOUBLE DOORS
S E
E S
C H
E D
U
LE
SCHEDULE
SEE
INACTIVE
LEAF
B
2"
INTERIOR PARTITION
METAL STUD LINTEL AS
REQ. FOR SPAN
METAL RUNNER CHANNEL
SEALANT, TYP.
HOLLOW METAL FRAME AS
SCHEDULED
DOOR AS SCHEDULED
M
IN
4" 2"
INTERIOR PARTITION
(2) METAL STUDS FLOOR TO TOP
OF WALL, BRACE TO STRUCTURE
SEALANT, TYP.
HOLLOW METAL FRAME (AS
SCHEDULED)
DOOR AS SCHEDULED
ADJACENT
WALL
(3) ANCHORS PER JAMB
PARTITION TYPE A1.1
SEALANT, BOTH SIDES
BOTTOM OF STRUCTURE
SEALANT, BOTH SIDES
TOP OF STRUCTURE
3 5/8" METAL STUD, 16"
O.C.
5/8" GYPSUM BOARD TYPE
CEILING AS SCHEDULED
3" SAFB
5"
S E
C T
IO
N
P
LA
N V
IE
W
S E
C T
IO
N
CEILING RUNNER, FASTEN TO STRUCTURE
AT 16": O.C., MINIMUM
FLOOR RUNNER, FASTEN TO STRUCTURE
AT 24": O.C., MINIMUM
FIRE RESISTANCE RATING = N/A
STC RATING = 49
NON-RATED PARTITION
A1.3
FIRE UL STC SAB
1HR 47 1 1/2"U419
NOTES
A1.2 N/A N/A N/AN/A
A1.5 N/A N/A N/AN/A
A1.4 1HR 49 3"U419
USE 1/2" GYP. BD.
N/A
N/A
STANDARD PARTITION PARTITION TYPE B1.1
SEALANT
BOTTOM OF STRUCTURE
SEALANT
TOP OF STRUCTURE
1 1/2" METAL STUD, 16"
O.C.
5/8" GYPSUM BOARD TYPE
CEILING AS SCHEDULED
1" SAFB
S E
C T
IO
N
P
LA
N V
IE
W
S E
C T
IO
N
CEILING RUNNER, FASTEN TO STRUCTURE
AT 16": O.C., MINIMUM
FLOOR RUNNER, FASTEN TO STRUCTURE
AT 24": O.C., MINIMUM
FIRE RESISTANCE RATING = N/A
STC RATING = 49
NON-RATED PARTITION
FURRING PARTITION
B.3
FIRE UL STC SAB NOTES
B.2 N/A N/A N/AN/A
B.5 N/A N/A N/AN/A
B.4
N/A
N/A
N/A N/A N/AN/A N/A
N/A N/A N/AN/A N/A
CL
MUNTIN W/ RECESSED
EGRESS DEVICES
BOTTOM RAILS
TOP RAILS
THERMALLY BROKEN
SADDLE ADA
THRESHOLD
EXTERIORINTERIOR
TOP HOUSING
ASSEMBLY
7" 5"
5"
1/ 2"
1/
2"SEALANT
SIDELITE ASSEMBLY W/ PIVOT
2"
SLIDING DOOR
ASSEMBLY W/ PIVOTS
BI PARTING DOOR FRAME
EXTERIOR
INTERIOR
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
A
BID DOCUMENTS
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans Affairs
B
C
D
E
F
A
B
C
D
E
F
21 4 5 6 7 8 9 10
Phase
ENGINEER OF RECORD STAMPSUBCONSULTANTS
321 4 5 6 7 8 9 10
DELTA ENGINEERS, ARCHITECTS & SURVEYORS
8401 CONNECTICUT AVE SUITE 350
CHEVY CHASE, MARYLAND 20815
301.718.0080
MORABITO CONSULTANTS, INC.
STRUCTURAL ENGINEERING
952 RIDGEBROOK ROAD, SUITE 1700
SPARKS, MARYLAND 21152
410.467.2377
KOFFEL ASSOCIATES, INC.
8815 CENTRE PARK DR STE 200
COLUMBIA, MD 21045
410.750.2246
VETERAN DESIGN & CONSTRUCTION INC.
5523 RESEARCH PARK DRIVE SUITE 110
BALTIMORE, MARYLAND 21228
443.543.5081
512-23-108RENOVATE C-SEGREGATED
COMPOUNDING AREA FOR
HAZARDOUS COMPOUNDING
VAMC BALTIMORE
F R e v it L o c a ls
\2
.8
.0
V
A M
C B a lt im o re
R e n o v a te C o m p o u n d in g v jd e a n h u n te r@ d e lt a -e a s .c o m
.r v t
/1
/2
:2
:2
P
M
AS-601
ARCHITECTURAL - SCHEDULES
05/17/2024 EJL JDH
SCALE: 1 1/2" = 1'-0"AS-601
1 DOOR HEAD DETAIL
SCALE: 1 1/2" = 1'-0"AS-601
2 DOOR JAMB DETAIL
DOOR SCHEDULE
DOOR
NUMBER
TO ROOM: NAME FLOOR LEVEL
DOOR FRAME
FIRE
RATING
GLASS
DETAILS
HARDWARE
GROUP
COMMENTSDOOR
TYPE
OPENING SIZE
THICKNESS DOOR MATERIAL DOOR FINISH
FRAME
TYPE
FRAME MATERIAL FRAME FINISH HEAD JAMB
HEIGHT WIDTH
101 PHARMACY BASEMENT A 7' - 0" 3' - 6" 1 3/4" SCW PNT F-1 HM PNT - 1/AS-601 2/AS-601 HW-1
102 ANTEROOM BASEMENT B 7' - 0" 5' - 11 7/8" ALUM ANOD G-1 ALUM ANOD - 4/AS-601 3/AS-601 HW-4
103 HOOD ROOM A BASEMENT A 7' - 0" 3' - 6" 1 3/4" SCW PNT F-1 HM PNT - 1/AS-601 2/AS-601 HW-2
104 HOOD ROOM B BASEMENT A 7' - 0" 3' - 6" 1 3/4" SCW PNT F-1 HM PNT - 1/AS-601 2/AS-601 HW-2
201 HOOD ROOM C SECOND FLOOR PLAN B 7' - 0" 3' - 6" 1 3/4" SCW PNT ETR ETR PNT 1/AS-601 2/AS-601 HW-3 REPLACEMENT DOOR IN EXISTING FRAME
SCALE: 1" = 1'-0"AS-601
5 PARTITION TYPES
WINDOW TYPE SCHEDULE
WINDOW
TAG TYPE
ROUGH OPENING FRAME DETAIL GLAZING
MANUFACTURER MODEL NO. COMMENTSWIDTH HEIGHT FRAME MATERIAL FRAME FINISH HEAD JAMB SILL THICKNESS TYPE
B PASS THROUGH WINDOW 1' - 0" 1' - 0" STAINLESS STEEL STAINLESS STEEL - - - - - CLEAN AIR
PRODUCTS
CAP18W-ST
D PASS THROUGH WINDOW 1' - 0" 1' - 0" STAINLESS STEEL STAINLESS STEEL - - - - - CLEAN AIR
PRODUCTS
CAP18W-SST
0'
SCALE: 1-1/2" = 1'-0"
2" 4" 1'-4"8"0'
SCALE: 1" = 1'-0"
3" 6" 2'1'
SCALE: 1 1/2" = 1'-0"AS-601
4 SLIDING HEAD DETAIL
SCALE: 1 1/2" = 1'-0"AS-601
3 SLIDING JAMB DETAIL
Revisions: Date:
P
M
MH-001
MECHANICAL - GENERAL NOTES,
SYMBOLS & ABBREVIATIONS
Revisions: Date:
T
SUPPLY AIR DEVICE. ARROWS
INDICATE DIRECTION OF BLOW
RETURN AIR DEVICE. ARROWS
INDICATE DIRECTION OF BLOW
MOTOR OPERATED DAMPER
BRANCH DUCT
TURNING VANES
DUCT TRANSITION
RECTANGULAR TO ROUND DUCT TRANSITION
THERMOSTAT
CONTROL VALVE (CV) - MODULATING
CONTROL VALVE (CV) - TWO-POSITION
CONTROL VALVE (CV) - 3-WAY MODULATING
CONTROL VALVE (CV) - 3-WAY TWO-POSITION
SHUT-OFF VALVE
OUTSIDE AIR DUCT
EXHAUST AIR DEVICE
AREA STATES CFM
AIR DEVICE DESIGNATION
AREA STATES NECK SIZES
STATES TYPE OF SYSTEM.
MECHANICAL EQUIPMENT DESIGNATION
STATES NUMBER OR LETTER CORRESPONDING
TO RELATED SCHEDULE.
LETTER REPRESENTS
MANUFACTURER &
MODEL NO.
RTU-XXX
CONNECT TO EXISTING
REMOVE FROM EXISTING
PLAN NOTE REFERENCE SYMBOL
MECHANICAL SYMBOLS AND ABBREVIATIONS
A/E ARCHITECT / ENGINEER
AP ACCESS PANEL
BDD BACKDRAFT DAMPER
BTU BRITISH THERMAL UNIT
BTUH BRITISH THERMAL UNIT PER HOUR
CD/COND CONDENSATE
CFH CUBIC FEET PER HOUR
CFM CUBIC FEET PER MINUTE
CHR CHILLED WATER RETURN
CHS CHILLED WATER SUPPLY
CO CLEANOUT
CV CONTROL VALVE
DB DRY-BULB TEMPERATURE
DEG DEGREE
DIA, Ø DIAMETER
DN DOWN
DP DIFFERENTIAL PRESSURE
DWG DRAWING
EF EXHAUST FAN
ENT ENTERING
ESP EXTERNAL STATIC PRESSURE
EWT ENTERING WATER TEMPERATURE
EX. EXISTING
F FAHRENHEIT
FD FLOOR DRAIN
GA GAUGE
GAL GALLONS
GPD GALLONS PER DAY
GPH GALLONS PER HOUR
GPM GALLONS PER MINUTE
HP HORSEPOWER
HPC HIGH PRESSURE RETURN (STEAM CONDENSATE)
HPS HIGH PRESSURE STEAM
HWC HOT WATER COIL
HWHC HOT WATER HEATING COIL
HWP HOT WATER PUMP
HWS HEATING HOT WATER SUPPLY
HWUH HOT WATER UNIT HEATER
HX HEAT EXCHANGER
HZ HERTZ
ID INSIDE DIAMETER
KW KILOWATT
KWH KILOWATT-HOUR
LPC LOW PRESSURE RETURN (STEAM CONDENSATE)
LPR LOW PRESSURE STEAM RETURN
LPS LOW PRESSURE STEAM SUPPLY
LWT LEAVING WATER TEMPERATURE
MAX MAXIMUM
MBH 1000 BTU'S PER HOUR
MCA MINIMUM CIRCUIT AMPACITY
MPS MEDIUM PRESSURE STEAM
MPC MEDIUM PRESSURE CONDENSATE
NA NOT APPLICABLE
NC NORMALLY CLOSED
NO NORMALLY OPEN
NO. NUMBER
NTS NOT TO SCALE
OA OUTSIDE AIR
P PUMP
PD PRESSURE DROP OR DIFFERENCE
PG PRESSURE GAGE
PH PHASE
PSI POUNDS PER SQUARE INCH
RA RETURN AIR
RPM REVOLUTIONS PER MINUTE
RX REMOVE EXISTING
SA SUPPLY AIR
SQFT/SF SQUARE FEET
TD TEMPERATURE DIFFERENCE
TDH TOTAL DYNAMIC HEAD
TEMP TEMPERATURE
TOT TOTAL
TYP TYPICAL
UH UNIT HEATER
V. VOLTS
VAV VARIABLE AIR VOLUME
VI VIBRATION ISOLATOR
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
BID DOCUMENTS
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans
Affairs
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseENGINEER OF RECORD STAMPSUBCONSULTANTS
321 4 5 6 7 8 9 10
05/17/2024Revisions: Date:
DELTA ENGINEERS, ARCHITECTS & SURVEYORS
8401 CONNECTICUT AVE SUITE 350
CHEVY CHASE, MARYLAND 20815
301.718.0080
MORABITO CONSULTANTS, INC.
STRUCTURAL ENGINEERING
952 RIDGEBROOK ROAD, SUITE 1700
SPARKS, MARYLAND 21152
410.467.2377KOFFEL ASSOCIATES, INC.
8815 CENTRE PARK DR STE 200
COLUMBIA, MD 21045
410.750.2246
VETERAN DESIGN & CONSTRUCTION INC.
5523 RESEARCH PARK DRIVE SUITE 110
BALTIMORE, MARYLAND 21228
443.543.5081
512-23-108RENOVATE C-SEGREGATED
COMPOUNDING AREA FOR
HAZARDOUS COMPOUNDING
VAMC BALTIMORE
MECHANICAL GENERAL NOTES
1. ALL WORK SHALL CONFORM TO LATEST INTERNATIONAL MECHANICAL AND PLUMBING CODES; VA
HVAC AND PLUMBING DESIGN MANUAL.
2. ALL WORK SHALL BE COORDINATED WITH ARCHITECTURAL, STRUCTURAL, FIRE PROTECTION, MECHANICAL AND ELECTRICAL DRAWINGS. CONTRACTOR SHALL BE REQUIRED TO FURNISH, INSTALL AND CONNECT WITH APPROPRIATE SERVICES ALL ITEMS SHOWN ON THE DRAWING AT NO
ADDITIONAL COST TO OWNER.
3. THE CONTRACTOR SHALL REVIEW THE WORK AND SHALL COORDINATE WITH THE WORK OF OTHER
TRADES.
4. SLEEVE AND SEAL ALL PIPING PASSING THROUGH WALLS, FLOORS AND ROOF UNLESS NOTED
OTHERWISE.
5. ALL HANGERS AND SUPPORTS SHALL BE SECURED TO STRUCTURE ABOVE.
6. ALL CUTTING, PATCHING AND REPAIR WORK SHALL BE THE RESPONSIBILITY OF THE TRADE
INVOLVED.
7. ALL INSULATION, FITTINGS, COVERS AND FINISHES SHALL HAVE A MAXIMUM FLAME SPREAD RATING OF 25 AND A MAXIMUM SMOKE DEVELOPED RATING OF 50 AND ALL BE IN COMPLIANCE WITH NFPA
90A. REFER TO SPECIFICATIONS.
8. ALL CORE DRILLING, CUTTING AND PATCHING SHALL BE DONE BY THE TRADE. PROVIDE FOR X-RAY
OR GPR OF ALL PENETRATIONS THRU STRUCTURAL SLAB OR WALLS.
9. ALL SLAB PENETRATIONS AND PENETRATIONS THRU RATED WALLS SHALL BE PROVIDED WITH
APPROVED FIRE STOP MATERIAL.
10. ALL EQUIPMENT SHALL BE INSTALLED IN SUCH A WAY TO FACILITATE MAINTENANCE & REPAIR AND
TO ENSURE FACTORY REQUIRED CLEARANCES ARE MET.
11. PROVIDE DETAILED COORDINATED SHOP DRAWINGS (SHEET METAL, PIPING ETC.) TO ENSURE ALL
SYSTEMS ARE COORDINATED AND ALL REQUIRED CEILING HEIGHTS CAN BE ACCOMMODATED.
12. ALL SPECIFICATIONS AND DRAWINGS, I.E. ARCHITECTURAL, STRUCTURAL, MECHANICAL, PLUMBING, FIRE PROTECTION, AND ELECTRICAL, ARE COMPLIMENTARY AND MUST BE USED IN COMBINATION
TO OBTAIN COMPLETE CONSTRUCTION INFORMATION.
13. ANY INFORMATION CONFLICTS WITHIN THE SPECIFICATIONS AND/OR DRAWINGS SHALL BE
BROUGHT TO THE ARCHITECT'S ATTENTION. THE CONTRACTOR SHALL NOT PROCEED WITH ANY
WORK UNTIL ALL CONFLICTS ARE RESOLVED AND THE CLARIFYING INFORMATION IS ISSUED.
14. THESE DRAWINGS ARE SCHEMATIC AND ARE INTENDED TO CONVEY A FUNCTIONAL SYSTEMS AND
TO DEPICT THE GENERAL LOCATION OF THE SYSTEMS' COMPONENTS.
15. THE CONTRACTOR SHALL COORDINATE THE INSTALLATION OF WORK WITH THE WORK OF OTHER TRADES. MINOR DEVIATIONS FROM THE PLANS MAY BE MADE TO AVOID MINOR CONFLICTS. WHEN MAJOR CONFLICTS ARE APPARENT, THE CONTRACT OFFICER SHALL BE ADVISED IMMEDIATELY AND
AFFECTED WORK SHALL NOT BE CONSIDERED UNTIL THE CONFLICT HAS BEEN RESOLVED.
16. THE CONTRACTOR SHALL VERIFY ALL VOLTAGE AND POWER REQUIREMENTS FOR ALL EQUIPMENT
AND COORDINATE WITH THE CONTRACT DRAWINGS PRIOR TO ISSUANCE OF SHOP DRAWINGS AND
PURCHASE OF EQUIPMENT.
17. ALL SYSTEMS SHALL BE CLEAN OF FOREIGN MATERIAL AND ROUGH SPOTS PRIOR TO BEING
PLACED IN SERVICE AND BEFORE OPERATIONAL TESTS ARE PERFORMED.
18. INSTALLATION OF ALL EQUIPMENT AND THEIR ACCESSORIES SHALL BE PER MANUFACTURER'S
PUBLISHED RECOMMENDATIONS.
FIRE DAMPER
DS
BALANCING VALVE
PHASING NOTES
1. CONSTRUCTION WORK SHALL START ON THE 2ND FLOOR. AFTER WORK ON THE
2ND FLOOR IS COMPLETE AND OPERATIONAL, BASEMENT WORK SHALL
COMMENCE TO ENSURE CONTINUOUS COMPOUNDING OPERATION.
DRUG INFO
BA120J
SUPV OFFICE
BA120D
CLERK
BA120F
ADMIN AREA
BA120
WAITING
BA120E
OFFICE
BA120C
CORRIDOR
CB-8
RX. EA GRILLE
RX. EA GRILLE
RX. VAV
RX. 14"Ø SA UP
RX. 10"ø SA
RX. 10"ø SA
RX. 10"ø SA
RX. 10"ø SA
RX. 10"ø SA
RX.10"ø EA
RX. FUME HOOD
RX. FUME HOOD
RX. 10"ø EA
RX. LAMINAR
FLOW DIFFUSER
w/HEPA FILTER
(TYP. OF 5)
EX. EA UP
INTO PLENUM
EX. EA GRILLE
RX. HEPA FAN FILTER
UNIT (TYP. OF 2)
RX. FUME
HOOD
EX. EA
GRILLE
EX. RA UP INTO PLENUM
RX. 22"x14 EA
EX. 10"Ø EA
EX. 10"Ø EA
DUCT RISE
E X x
S
A
EX. 12"x10" SA
E X x
R
A
E X x
E
A
E X x
R
A
EX. RA DIFFUSER
EX. 22"x14" EA
EX. 10"Ø SA
EX. 28"x16" SA
EX. VAV
EX. 28"x16" RA
EX. VAV
EX. 10"Ø SA
EX. 16"x12" SA
EX. 1
" HWS
AND HWR
EX. HWS
AND HWR
EX. 1
" HWS
AND HWR
INPT PHARMACY
BA121
INVESTIGATIVE DRUG SVC
BA121L
R X
S
A
CLEAN ROOM SUITE
BA121L
CHEMO HOOD
BA121K
HOOD ROOM
CLEAN ROOM SUITE
BA121L
CHEMO HOOD
BA121K
HOOD ROOM
EXISTING TO REMAIN
ENTRY
RX. 16"x6"
TRANSFER
AIR GRILLE
(TYP. OF 2)
RX. 12"x4" TRANSFER
GRILLE (TYP. OF 2)
UP
DN
C.7
C.8
D
D.3
E
ELEVATOR
LOBBY
8A100
ELEVATOR
S-8
ELEVATOR
S-9
MECH
EQUIP RM
8D100
STAIR
RX. 1-CF-66
RX. AIRFLOW
CONTROL VALVE
RX. 9"x12" EA
EX. 10"Ø EA
RX. EA
DUCT UP
EX. 1-CF-64
EX. 1-CF-75
EX. 1-CF-131
EX. 1-CF-130
RX. HEPA
FILTER
EX. 10"Ø
DOWN
EX. 12"Ø
DOWN
EX. 12"Ø EA
EX. 1-CF-63
EX. 1-CF-129
EX. MCC-8
EX. PANEL 8D-L1
EX. UH
EX. FD
EX. FD
EX. 50"x24"
EA
EX. 28"x30"
EX. 20"x28"
EX.
18"x22"
EX.
10"x12"
EX. FD
EX. UH
EX. MOD
EX. PANEL 8D-L
EX. T2-8DL
EX.
DISCONNECT
RX. 8"Ø
EA
EX. 8"x8"
EX. HEPA
FILTER
EX. JC1
CONTROL
PANEL
EX. MOD
EX. 12"x12" RA
EX. 10"Ø RA
RX. VAV
RX. 14"x12" SA
RX. 8"Ø
RX. 10"x10" SA
EX.
" HWS AND HWR
HOOD ROOM C
RX.
" HWS
AND HWR
HOOD ROOM C
2C-126
RX. RA DIFFUSER
RX. 10"Ø RA UP TO
INTERSTITIAL SPACE
RX. 8"Ø SA UP TO
INTERSTITIAL SPACE
RX. BASEBOARD HEATERS
RX. 8"Ø SA
UP TO
INTERSTITIAL
SPACE
RX. LINEAR SLOT DIFFUSER
(TYP. OF 2)
EX. RA
DIFFUSER
HOOD ROOM C
2C-126
EX. 10"Ø RA UP TO
INTERSTITIAL SPACE
A
M
MD-101
SCALE: 1/4" = 1'-0"
BASEMENT PART PLAN - DEMOLITION
Project Number
Building Number
Drawing Number
Project Title
Location
Issue Date Checked Drawn
Drawing Title
Approved:
VA FORM 08 - 6231
BID DOCUMENTS
FULLY SPRINKLERED
Office of Construction and Facilities Management
U.S. Department of Veterans
Affairs
A
B
C
D
E
F
21 4 5 6 7 8 9 10
PhaseENGINEER OF RECORD STAMPSUBCONSULTANTS
321 4 5 6 7 8 9 10
05/17/2024Revisions: Date:
DELTA ENGINEERS, ARCHITECTS & SURVEYORS
8401 CONNECTICUT AVE SUITE 350
CHEVY CHASE, MARYLAND 20815
301.718.0080
MORABITO CONSULTANTS, INC.
STRUCTURAL ENGINEERING
952 RIDGEBROOK ROAD, SUITE 1700
SPARKS, MARYLAND 21152
410.467.2377KOFFEL ASSOCIATES, INC.
8815 CENTRE PARK DR STE 200
COLUMBIA, MD 21045
410.750.2246
VETERAN DESIGN & CONSTRUCTION INC.
5523 RESEARCH PARK DRIVE SUITE 110
BALTIMORE, MARYLAND 21228
443.543.5081
512-23-108RENOVATE C-SEGREGATED
COMPOUNDING AREA FOR
HAZARDOUS COMPOUNDING
VAMC BALTIMORE
KEYPLAN
C D
B A
NORTH
0'
SCALE: 1/4" = 1'-0"
1' 2' 8'4'0'
SCALE: 1/8" = 1'-0"
2' 4' 16'8'
MECHANICAL - FLOOR PLANS -
DEMOLITION
SCALE: 1/8" = 1'-0"
EIGHTH FLOOR PART PLAN - DEMOLITION
2ND FL
AREA OF WORK
BASEMENT
AREA OF WORK
EIGHTH FL.
AREA OF WORK
GENERAL NOTES
A. DUCTWORK SHOWN ON "SECOND FLOOR PART PLAN - DEMOLITION"
IS LOCATED IN INTERSTITIAL SPACE.
PLAN NOTES
CUT AND CAP EX. 22"x14" EA AT PHARMACY WALL AND PREPARE
FOR RECONNECTION.
REMOVE VERTICAL EA DISCHARGE DUCT AS NECESSARY TO
FACILITATE INSTALLATION OF NEW FANS. EX. EXHAUST STACK AT
ROOF TO REMAIN.
EX. 10"Ø EA TO DUCT CHASE NEAR COLUMN LINE D.3 AND BETWEEN
COLUMN LINES 8 AND 9. NOTE 4 ON "EIGHTH FLOOR PART PLAN"
INDICATES THIS LOCATION.
REFER TO PLAN NOTE 3.
CUT AND CAP 12"x12" RA.
REFER TO "SECOND FLOOR INTERSTITIAL PART PLAN" ON THIS
SHEET FOR CONTINUATION.
REFER TO "SECOND FLOOR PART PLAN" ON THIS SHEET FOR
CONTINUATION.
MB
SCALE: 1/4" = 1'-0"
SECOND FLOOR INTERSTITIAL PART PLAN - DEMOLITION
SCALE: 1/4" = 1'-0"
SECOND FLOOR PART PLAN - DEMOLITION
10"ø SA
VAVS-1
12"ø SA
EX. 10"Ø EA RISE
10"ø EA
DRUG INFO
BA120J
SUPV OFFICE
BA120D
CLERK
BA120F
ADMIN AREA
BA120
WAITING
BA120E
OFFICE
BA120C
CORRIDOR
CB-8
EX. EA
GRILLE
(UNDER)
EX. EA
GRILLE
(UNDER)
12"ø
A
8"ø
A
12"ø
A
12"ø
A
EX. 10"Ø EA
(TYP OF 2)
OFFICE
BA120A
SUPV OFFICE
BA120B
E X x
S
A
EX. 12"x10" SA
E X x
R
A
E X x
E
A
E X x
R
A
EX. RA DIFFUSER
EX. 22"x14" EA
EX. 10"Ø SA
EX. 28"x16" SA
EX. VAV
EX. 28"x16" RA
EX. VAV
EX. 10"Ø SA
E X x
S
A
12"ø SA
12"ø
A
EX. 1
" HWS
AND HWR
EX. HWS
AND HWR
EX. 1
" HWS
AND HWR
12"x14" SA
VAVS-4
12"ø EA
12"ø SA 16"x10" SA
VAVS-3
16"ø SA
8"ø SA
12"ø SA
8"ø SA
10"ø SA8"ø SA
10"x10" EA
(TYP. OF 2)
10"x10" EA
12"x12" EA
VAVS-2
22"x14" EA
T H
T H
T H T H
" HWS
AND HWR
(TYP. OF 3)
PHARMACY
BA121K
ANTEROOM
BA121L
HOOD ROOM A
BA121O
HOOD ROOM B
BA121P
14"x18"
750B
6"x8"
125B
8"x6" EA
8"ø EA
" FLEXIBLE
TUBING (TYP.)
EXISTING TO REMAIN
ENTRY
EX. 12"x12" RA
EX. 10"Ø RA
VAVS-5
14"x10" SA
12"Ø EA
REFER TO SHEET
MH102 FOR
CONTINUATION
EX.
" HWS AND HWR
10"Ø SA
10"Ø SA
HOOD ROOM C
2C126
EF-5
12"x6" EA
13 13
ENTRY
UP
DN
C.7
C.8
D
D.3
E
ELEVATOR
LOBBY
8A100
ELEVATOR
S-8
ELEVATOR
S-9
MECH
EQUIP RM
8D100
STAIR
EF-3
EF-4
FLTR-2
12"Ø EA
NEW HEAVY
DUTY DAMPER
(TYP. OF 2)
EA UP
THRU
ROOF
VAVE-2
EX. 10"Ø EA
EX.
1-CF-64
EX. 1-CF-75
EX. 1-CF-131
EX. 1-CF-130
EX. 10"Ø
DOWN
EX. 12"Ø
DOWN
EX. 12"Ø
EA
EX. 1-CF-63
EX. 1-CF-129
EX. MCC-8
EX. PANEL 8D-L1
EX. UH
EX. FD
EX. FD
EX. 50"x24"
EA
EX. 28"x30"
EX. 20"x28"
EX.
18"x22"
EX. 10"x12"
EX. FD
EX. MOD
EX. PANEL 8D-L
EX. T2-8DL
EX.
DISCONNECT
EX.