About this file

The document is a technical marketing brochure from Premier Magnesia, LLC for THIOGUARD® TST, a total system treatment solution for municipal wastewater collection systems. The brochure details a comprehensive treatment approach addressing force main gas binding, focusing on reducing operational challenges in wastewater infrastructure such as gas emissions, fats/oils/greases (FOG) accumulation, and system corrosion. THIOGUARD® proposes to help municipalities save up to 50% annually on pump station power costs by mitigating negative conditions in wastewater collection systems.

The technical literature compares THIOGUARD® to calcium nitrate treatments, demonstrating how their product can neutralize acid, reduce gas production, minimize grease accumulation, and improve overall system efficiency. The product is positioned as a non-hazardous solution with no reportable quantities, capable of reducing hydrogen sulfide generation, maintaining higher pH levels, and preventing infrastructure corrosion. The brochure includes detailed scientific diagrams illustrating gas binding processes and the comparative effectiveness of THIOGUARD® across different miles of a force main system, emphasizing its ability to neutralize both surface and wastewater acid over short and long distances.

View the file

Other files

Show all 11

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

OWNED, MINED

AND PRODUCED

IN THE USA

THIOGUARD.COM

1.800.227.4287

EFFECTIVE, ENVIRONMENTALLY SAFE TOTAL SYSTEM TREATMENT FOR MUNICIPAL WASTEWATER

NEWSLETTER ARCHIVE

Online Archive of the

THIOGUARD® Newsletter Series

RESOURCES

Website links and information related to THIOGUARD®

THIOGUARD® TST is a non-hazardous application with no required reportable quantities (RQ = None)

Premier Magnesia, LLC is a global market leader in magnesia-based products and solutions.

© PREMIER MAGNESIA | ISO 9002:1994

FORCE MAIN GAS BINDING

PROBLEM STATEMENT:

Pumping and conveying of wastewater from end user through the collection system to wastewater treatment plants can result in negative conditions including gas binding, blockages associated with fats, oils and greases (FOG), and system corrosion. There may be other contributing conditions, but these factors appear to be the greatest contributors to O&M costs including energy consumption, maintenance costs, and Sanitary Sewer Overflows (SSOs).

50%

SAVE UP TO

a year in pump stations power costs by choosing

THIOGUARD®!

EFFECTIVE, ENVIRONMENTALLY SAFE TOTAL SYSTEM TREATMENT FOR MUNICIPAL WASTEWATER

BACKGROUND:

A collection system line is a unique conveyance system. The transfer of wastewater can result in the release of gases such as O2 – Oxygen, CO2 – Carbon Dioxide, N2 – Nitrogen Gas, H2S – Hydrogen Sulfide, CH4 – Methane, VOCs – Volatile Organic Compounds, and VOSCs – Volatile Organic Sulfur Compounds among others. Some of these gases are drawn into the system through pumping and ventilation, while others are generated within the system either chemically or biologically. These gases can result in the development of gas binding in the system, especially with the utilization of calcium nitrate, as well as contribute to odors and corrosion.

H2SO4

H2SO4

FLOATING

ORGANIC

MATTER &

GREASE

NO3

NO3SO4 NO3

NO3

O2 N2 O2

O2

PUMPING STATION

CO2 CO2

CO2

N2 N2

N2

NO

H2S

H2S H2S

N2

N2

N2

CO2

CO2

N2N2

N2 H2S

H2S

H2S H2S H2S H2S

H2SH2S

CH4

VOC

VOC

VOSC

VOSC

CALCIUM

NITRATE

INCREASED GAS BINDING PRESSURE

H2S

H2S H2S

H2S H2S H2S H2S CH4 H2S

CaNO3

ARV

INCREASED TRAPPED GAS

H2SO4

LOW pH (RED)

HIGHLY CORROSIVE

MILE 1 MILE 2 MILE 3 MILE 4 MILE 5 MILE 6

Aerobic Bacteria

Facultative Bacteria & Sulfate Reducing Bacteria

N2 gas formed in wet well can cause suction inefficiency at pump intake

FOG exacerbated by biological conditioning caused by nitrates

VFAs (Volatile Fatty Acids) are eliminated with calcium nitrate addition that are needed by PAOs (phosphorus accumulating organisms) for phosphate removal at the wastewater treatment plant.

Acid Producers & Methanogens

Bacteria use O from SO4 producing H2S gas At pH7 >50% of H2S can be liberated into the gas phase

1. Large amounts of NO3 available

2. O from NO3 used by bacteria reducing NO3 to N2 & NO

Dissolved O2 used first producing CO2

Force Main With Calcium Nitrate (CaNO3) Liquid Phase Treatment

THIOGUARD® VS NITRATE

Baseline Nitrate Thioguard

500,000 GPD Pump Station Monthly Power Cost

$5,000

$4,500

$3,500

$2,500

$1,500

$2,000

$4,000

$3,000

$24,000 / yr.

Save up to 50% per year in pump station power costs by choosing THIOGUARD® as your odor, FOG and corrosion control process in your collection system.

FORCE MAIN GAS BINDING DRAMATICALLY INCREASED

WITH CALCIUM NITRATE (CaNO3) ADDITION

SOLUTION:

THIOGUARD® can overcome these issues by reducing or eliminating gas emissions from wastewater, dissolving FOG blankets and reducing corrosion to pumps and infrastructure. No other product can match THIOGUARD®'s ability to neutralize both collection system surface acid and wastewater acid over short and long distances to and through the wastewater treatment plant.

EFFECTIVE, ENVIRONMENTALLY SAFE TOTAL SYSTEM TREATMENT FOR MUNICIPAL WASTEWATER

THIOGUARD.COM | 1.800.227.4287

THIOGUARD® HEADQUARTERS: 1275 Drummers Lane, Suite 102 | Wayne, PA 19087

MINIMAL

GREASE IN

WETWELL

SO4

pH 8.2 pH 8.2 pH 8.2 pH 8.2 pH 8.2 pH 8.2

SO4

O2 O2

O2

PUMPING STATION

CO2

H2S

H2S

H2S

Mg(HS-)2

Mg(HS-)2 Mg(HS-)2

CO2

CO2

CO2

CO2

CO2

CO2

H2S

REDUCED

VOSC

H2S

H2S

ARV

LESS GAS PRODUCED

INCREASED SURFACE pH = LESS CORROSION

THIOGUARD®

REDUCED GREASE

PLUGGING

THIOGUARD®

Less CO2 is produced with THIOGUARD®, as CO2 gas is held in solution similarly to H2S

THIOGUARD® INCREASES SURFACE

pH TO NEUTRAL pH (WHITE)

PREVENTING INFRASTRUCTURE

CORROSION

Bacteria

Facultative Bacteria & Sulfate Reducing Bacteria Acid Producers & Methanogens

Sulfate reducing bacterial activity greatly reduced producing very little H2S gas. Liquid/gas phase equilibrium shifted to keep HS- in solution

HS- Combines with Mg+ to produce a soluble magnesium complex

Anaerobic activity retarded by increased pH

THIOGUARD has long range buffering capacity to neutralize acid attack on infrastructure

No NO3 present Dissolved O2 used first producing CO2

Force Main With THIOGUARD® Treatment

H2S

CO2

CH4

FLOATING

GREASE

O2

O2

O2

PUMPING STATION

CO2 CO2

H2S H2S

CO2

CO2

CO2

H2S

H2S VOC

VOSCH2S

CO2

H2S

H2S VOC

VOSC

H2S

CO2

H2S CH4 CH4CO2 H2S

ARV

TRAPPED GASGREASE ACCUMULATION

PLUGGING ARVs

H2S

H2SH2S

H2S

Bacteria

Facultative Bacteria & Sulfate Reducing Bacteria Acid Producers & Methanogens

Bacteria use O from SO4 producing H2S gas At pH7 >50% of H2S can be liberated into the gas phase

Thiobacillus Bacteria convert

H2S into Sulfuric Acid

1. Little or no NOx present

2. Begin using other forms of combined O

Dissolved O2 used first producing CO2

LOW pH (RED)

HIGHLY CORROSIVE

Force Main with No Liquid Phase Treatment

Call 1.800.227.4287 or Email thioguard2@premiermagnesia.com

Visit www.thioguard.com to learn more about how THIOGUARD® can help your plant!

File details come from the government source that posted it. Updated .