02.0 Attachment 02 - Price Schedule of Hazardous Waste Services for Hawaii_20210430.xlsx

XLSX spreadsheet 100 KB Posted

Attached to
HAWAII HAZARDOUS WASTE REMOVAL & DISPOSAL
Solicitation number
SP450021RXXXX
Issued by

View the file

Other files

Show all 16

On GovTribe

Work with this file

  • Download the original file
  • Contacts named in this file
  • Similar government files
  • Ask GovTribe AI about this file

Text version

BID

Master Price Schedule / Estimated Quantity v0430202130 -Month Base Period30 -Month Option PeriodContract Total
Base
CLINServices DescriptionEst. QtyEst. QtyU/MPriceExtended PriceEst. QtyU/MPriceExtended Price
6311AAProvide service and container to place waste in containers - up to one 5 gal container (See 1.2.13)4,4502,225EA$0.00$0.002,225EA$0.00$0.00
6311BBProvide service and containerto place waste in containers - (6-15 gallon containers) (See 1.2.13)1,780890EA$0.00$0.00890EA$0.00$0.00
6311CCProvide service and containerto place waste in containers - (16- to 30-gallon container) (See 1.2.13)2,5001,250EA$0.00$0.001,250EA$0.00$0.00
6311DDProvide service and container to place waste in containers - (31 - 55 gallon container) (See 1.2.13)4,4502,225EA$0.00$0.002,225EA$0.00$0.00
6311EEProvide service and containerto place waste in containers - (Tri-wall or CYB Suffix (C6)) (See 1.2.13)17889EA$0.00$0.0089EA$0.00$0.00
6311DZProvide Container, Steel Drum, New. 55 gl Open Top w/Heavy Bolt Ring [See 1.2.3]5025EA$0.00$0.0025EA$0.00$0.00
6311DWProvide Container, Steel Drum, New. 85 gl Overpack [See 1.2.3]53EA$0.00$0.003EA$0.00$0.00
6311EIProvide Container, Poly Drum, New, 85 gl Overpack [See 1.2.3]53EA$0.00$0.003EA$0.00$0.00
6311EQProvide Container, Steel Drum, Reconditioned. 30 gl Open Top with Heavy Bolt Ring [See 1.2.3]7035EA$0.00$0.0035EA$0.00$0.00
6314TPProvide Container, 275 gallon Tote [See 1.2.3]21EA$0.00$0.001EA$0.00$0.00
6316DJProvide Container, 30 gl Poly Drum, New UN 1A2/X235/S [See 1.2.3]2613EA$0.00$0.0013EA$0.00$0.00
6320Provide and Prepare Lab Packs, consisting of small quantity chemicals (56 - 85 gl) [See 3.27]21EA$0.00$0.001EA$0.00$0.00
6321Provide and Prepare Lab Packs, consisting of small quantity chemicals (55 gl) [See 3.27]42EA$0.00$0.002EA$0.00$0.00
6322Provide and Prepare Lab Packs, consisting of small quantity chemicals (20-30 gl) [See 3.27]21EA$0.00$0.001EA$0.00$0.00
6323Provide and Prepare Lab Packs, consisting of small quantity chemicals (5-15 gl) [See 3.27]105EA$0.00$0.005EA$0.00$0.00
6324Provide and Prepare Lab Packs, consisting of small quantity chemicals (<5 gl)[See 3.27]21EA$0.00$0.001EA$0.00$0.00
6352BBTank cleaning/services – oil/water separator, 1,001 to 3,000 gal capacity (See 3.13)74EA$0.00$0.004EA$0.00$0.00
6352CCTank cleaning/services – oil/water separator, 3,001 to 6,000 gal capacity (See 3.13)42EA$0.00$0.002EA$0.00$0.00
1020REProvide Container, Rental, Daily (20cy) [See 3.1]42EA$0.00$0.002EA$0.00$0.00
1021REProvide Container, Rental, Weekly (20cy) [See 3.1]11EA$0.00$0.001EA$0.00$0.00
1040REProvide Container, Rental, Daily (40cy) [See 3.1]11EA$0.00$0.001EA$0.00$0.00
1041REProvide Container, Rental, Weekly (40cy) [See 3.1]11EA$0.00$0.001EA$0.00$0.00
1100SVMove empty roll-off box (See 3.10)32EA$0.00$0.002EA$0.00$0.00
1095SV1-Business Day Expedited Removal/Performance [See 1.1.4]32EA$0.00$0.002EA$0.00$0.00
1096SV3-Business Day Expedited Removal/Performance [See 1.1.4]2312EA$0.00$0.0012EA$0.00$0.00
1097SV5-Business Day Expedited Removal/Performance [See 1.1.4]6030EA$0.00$0.0030EA$0.00$0.00
1098SV10-Business Day Expedited Removal/Performance [See 1.1.4]5327EA$0.00$0.0027EA$0.00$0.00
6388Transportation [See 3.16]42EA$0.00$0.002EA$0.00$0.00
6388WLRound-Trip transportation of IBC from West Lock (See 3.41)126EA$0.00$0.006EA$0.00$0.00
6400AAPrepare Waste Profile Form [See 3.25]21EA$0.00$0.001EA$0.00$0.00
6401Perform Hazardous Waste Characteristics Analysis to determine ignitability (D001), corrosivity (D002), reactivity (D003) [See 3.24]63EA$0.00$0.003EA$0.00$0.00
6401HAPerform Hazardous Waste Characteristics Analysis to determine ignitability (D001) [See 3.24]4925EA$0.00$0.0025EA$0.00$0.00
6401HBPerform Hazardous Waste Characteristics Analysis to determine corrosivity (D002) [See 3.24]21EA$0.00$0.001EA$0.00$0.00
6401HCPerform Hazardous Waste Characteristics Analysis to determine reactivity (D003) [See 3.24]21EA$0.00$0.001EA$0.00$0.00
6402Perform total TCLP analysis (D004-D043) [See 3.24]158EA$0.00$0.008EA$0.00$0.00
6403Perform TCLP Metals analysis to determine 8 TCLP metals (D004-D011) [See 3.24]19799EA$0.00$0.0099EA$0.00$0.00
6405Perform TCLP analysis to determine volatile and semi-volatile organics (D018-D043) [See 3.24]21EA$0.00$0.001EA$0.00$0.00
6406Perform F-series solvent analysis to determine EPA waste codes F001-F005 [See 3.24]11EA$0.00$0.001EA$0.00$0.00
6408Perform Total Organic Halogens analysis [See 3.24]63EA$0.00$0.003EA$0.00$0.00
6409Perform Total Petroleum Hydrocarbons (TPH) Analysis [See 3.24]2010EA$0.00$0.0010EA$0.00$0.00
6410Testing unknown compressed gas cylinders [See 3.26]21EA$0.00$0.001EA$0.00$0.00
6411Perform Volatile Organics Analysis (EPA Method 8240) [See 3.24]21EA$0.00$0.001EA$0.00$0.00
6414Perform Wastewater/Non Wastewater Determination in Accordance w/ 40 CFR Part 268.2 [See 3.24]63EA$0.00$0.003EA$0.00$0.00
6421Perform Test for Asbestos [See 3.24]21EA$0.00$0.001EA$0.00$0.00
6422Determine Benzene, Toluene, Ethylbenzene, and Xylene (BTEX) [See 3.24]2010EA$0.00$0.0010EA$0.00$0.00
6424Perform Polychlorinated Biphenyl (PCB) analysis [See 3.24]9849EA$0.00$0.0049EA$0.00$0.00
6500 - 6699 Service CLINs
6502Perform Management Related Services. May include (but is not limited to) preparation of waste documentation, packing, labeling and marking containers, transportation of waste, pumping waste, spill response, reactives stabilization. [See 3.28]21EA$0.00$0.001EA$0.00$0.00
6502ESBulk pumping from IBC to 55-GL drums. One Each (1EA) equals up to ten (10) 55 GL containers or equivilent. (See 3.42)126EA$0.00$0.006EA$0.00$0.00
6503Provide Certificates of Destruction (CD) or Certificates of Recycling [See 2.1]21EA$0.00$0.001EA$0.00$0.00
6601Evaluate unknown compressed gas cylinder[See 2.3.1]21EA$0.00$0.001EA$0.00$0.00
6609AAPerform Services, may include repackaging the contents of one compressed gas cylinder that is not DoT transportable (non-inert gas) [See 2.3.3]11EA$0.00$0.001EA$0.00$0.00
6609BBPerform Services, may include replacing a valve that is not operable [See 2.3.3]11EA$0.00$0.001EA$0.00$0.00
6610HAMobilize for waste pick-up off the island of Oahu [See 3.18]158EA$0.00$0.008EA$0.00$0.00
6610HTPerform leak proof/hydrostatic testing on IBCs and provide compliance documentation126EA$0.00$0.006EA$0.00$0.00
6615DRRemoval and Disposal of Carbon Columns [See 3.40]126EA$0.00$0.006EA$0.00$0.00
Profile Based CLINs
Base
CLINBatteriesPBCEst. QtyEst. QtyU/MPriceExtended PriceEst. QtyU/MPriceExtended Price
BA01Alkaline Batteries, for Contractor's choice of recycling or disposal.BA01C710,0005,000LBS$0.00$0.005,000LBS$0.00$0.00
BA03Carbon-Zinc (CZn) Batteries, for Contractor's choice of recycling or disposal.BA03C710050LBS$0.00$0.0050LBS$1.00$50.00
BA04Lead Acid Batteries, Wet, Dry, or Gel Pack, for mandatory recycling.BA04C775,75037,875LBS$0.00$0.0037,875LBS$0.00$0.00
BA05Lithium Ion (Li-Ion) Batteries, for mandatory recycling.BA05C730,00015,000LBS$0.00$0.0015,000LBS$0.00$0.00
BA06Lithium Iron Disulfide (Li2FeS2) Thermal Batteries, including fully discharged Lithium Alloy Thermal Batteries, for Contractor's choice of recycling or disposal.BA06C795LBS$0.00$0.005LBS$0.00$0.00
BA10Lithium Batteries, Mixed Types, deactivated if applicable, for Contractor's choice of recycling or disposal.BA10C716,9938,497LBS$0.00$0.008,497LBS$0.00$0.00
BA11Magnesium (Mg) Batteries, for Contractor's choice of recycling or disposal.BA11C742LBS$0.00$0.002LBS$0.00$0.00
BA12Mercury (Hg) Batteries, for mandatory recycling.BA12C742LBS$0.00$0.002LBS$0.00$0.00
BA13Nickel Metal Hydride (NiMh) Batteries, Wet and Dry, for mandatory recycling.BA13C74,6022,301LBS$0.00$0.002,301LBS$0.00$0.00
BA14Nickel-Cadmium (NiCd) Batteries, Wet and Dry, for mandatory recycling.BA14C715,0007,500LBS$0.00$0.007,500LBS$0.00$0.00
BA15Silver-Zinc (AgZn) and Zinc Silver Oxide (ZnAgO) Batteries, for mandatory recycling.BA15C73216LBS$0.00$0.0016LBS$0.00$0.00
Base
CLINCorrosivesPBCEst. QtyEst. QtyU/MPriceExtended PriceEst. QtyU/MPriceExtended Price
CS01Corrosive Acids, Inorganic other than HF and HNO3, <50% in Water, Non-Fuming, <1% Total Metals, Cr+6 <100 ppm.

Physical State: Liquid

Permissible Waste Codes: D002, D004-11, Listed Inorganics.CS01C780,61240,306LBS$0.00$0.0040,306LBS$0.00$0.00
CS04Corrosive Acids, Chromic (H2CrO4), <1% Cr+6, Characteristic Liquids, Solids, Sludges, Debris.

Physical State: Various

Permissible Waste Codes: D001 (Oxidizer), D002, D004-11.CS04C78,3514,176LBS$0.00$0.004,176LBS$0.00$0.00
CS10Corrosive Alkalines, Inorganic, <50% in Water, <1% Total Metals, Cr+6 <100 ppm, No Ammonia/Amines.

Physical State: Liquid

Permissible Waste Codes: D002, D004-11, Listed Inorganics.CS10C7868434LBS$0.00$0.00434LBS$0.00$0.00
CS12Corrosive Ammonia/Amines, Organic/Inorganic, Liquids/Sludges/Solids/Debris, Flashpoint ≥140◦F. Physical State: Liquid
Permissible Waste Codes: D002, D004-11, Listed Inorganics.CS12C77,6993,850LBS$0.00$0.003,850LBS$0.00$0.00
CS13Corrosive Organic Acids or Bases, Liquids/Sludges/Solids/Debris, No Ammonia/Amines, Flashpoint ≥140◦F.

Physical State: Various

Permissible Waste Codes: D002, D004-43, Listed.CS13C7400200LBS$0.00$0.00200LBS$0.00$0.00
CS14Corrosive Inorganic Acids or Bases with Debris and Free Liquids, No Ammonia/Amines, Non-Flammable, including broken lead acid batteries.

Physical State: Various

Permissible Waste Codes: D002, D004-11, Listed.CS14C72,0511,026LBS$0.00$0.001,026LBS$0.00$0.00
CS15Corrosive Aerosols, Non-Ignitable and Non-Reactive, even when managed as UW.

Physical State: Various Permissible Waste Codes: D002, D004-11, Listed.

CS15C77839LBS$0.00$0.0039LBS$0.00$0.00
Base
CLINCompressed Gas Cylinders (CGC) Cartridges • Canisters • Vessels
Lecture (ME) = 3"x 12" • Small (M1) = 4"x 24" Medium (M2) = 12"x 36" • Large (M3) = 16"x 56"PBCEst. QtyEst. QtyU/MPriceExtended PriceEst. QtyU/MPriceExtended Price
CY01Cylinders, Category 1, for Disposal/Recycle/Reuse. Lecture (ME) = 3"x12", Small (M1) = 4"x24", Medium (M2) = 12"x36", Large (M3) = 16"x56".

Physical State: Comp. Gas

Permissible Waste Codes: As Appropriate to Each Gas.CY01ME10050EA$0.00$0.0050EA$0.00$0.00
Base
CLINFlammables • Combustibles • IgnitablesPBCEst. QtyEst. QtyU/MPriceExtended PriceEst. QtyU/MPriceExtended Price
FL01Aerosols, Flammable/Combustible/Ignitable, non-foaming. No isocyanates, reactives, or corrosives, even when managed as UW.

Physical State: Various Permissible Waste Codes: UW, D001 (IGN), D004-43, Listed

FL01C720,00010,000LBS$0.00$0.0010,000LBS$0.00$0.00
FL03Flammable Liquids/Solids/Sludges/Debris, e.g., tank sludge, lubricants, adhesives, miscellaneous debris, non-reactive paint waste with isocyanates, primarily consists of incinerable, non-fuels-blendable materials. Use LP03 for loose packs.

Physical State: Various

Permissible Waste Codes: D001-2, D004-43, Listed.FL03C755,25027,625LBS$0.00$0.0027,625LBS$0.00$0.00
FL04Flammable Corrosive Liquids/Solids/Sludges/Debris/Aerosols. Use LP03 for loose packs other than aerosols; FL04C7 for use with flammable corrosive aerosols only.

Physical State: Various

Permissible Waste Codes: UW (Aerosols Only), D001 (IGN), D002, D004-43, Listed.FL04C710,0005,000LBS$0.00$0.005,000LBS$0.00$0.00
FL05Flammable Liquids, Pumpable, Fuels Blendable, Rich, >7,000 BTU/Lb, <5% total chlorine, no isocyanates.

Physical State: Liquid

Permissible Waste Codes: D001 (IGN), D004-43, Listed.FL05C7325,000162,500LBS$0.00$0.00162,500LBS$0.00$0.00
FL07Flammable Liquids, Pumpable, Fuels Blendable, Lean to Rich, >2,500 BTU/Lb, 5-10% total chlorine, no isocyanates.

Physical State: Liquid

Permissible Waste Codes: D001 (IGN), D004-43, Listed.FL07C71,000500LBS$0.00$0.00500LBS$0.00$0.00
FL99Military Items, Demil-required, Flammable Solids/Liquids/Debris, e.g., CDE Kits, Vials, Filters, PPE, etc. for conventional RCRA treatment, disposal. CD required.

Physical State: Various

Permissible Waste Codes: D001 (IGN), D002, D004-43, Listed.FL99C716683LBS$0.00$0.0083LBS$0.00$0.00
Base
CLINLab Packs • Loose PacksPBCEst. QtyEst. QtyU/MPriceExtended PriceEst. QtyU/MPriceExtended Price
LP01Lab Packs/Loose Packs, Corrosives, Organic or Inorganic, Liquids or Solids, Non-Flammable.

Physical State: Various

Permissible Waste Codes: D002, D004-8, D010-11, ListedLP01C710,0135,007LBS$0.00$0.005,007LBS$0.00$0.00
LP03Lap Packs/Loose Packs, Flammables and Flammable Corrosives, other than paints and paint-related materials eligible for LP14, for mandatory RCRA incineration.

Physical State: Various Permissible Waste Codes: D001-2, D004-8, D010-43, Listed

LP03C740,00020,000LBS$0.00$0.0020,000LBS$0.00$0.00
LP04Lab Packs/Loose Packs, Non-RCRA, State and Non-State Regulated, other than paints eligible for LP15, includes pharmaceuticals.

Physical State: Various

Permissible Waste Codes: N/A.LP04C768,00034,000LBS$0.00$0.0034,000LBS$0.00$0.00
LP06Lab Packs/Loose Packs, Reactive Oxidizers, including Organic Peroxides, for mandatory RCRA incineration. Special packaging may be required. Physical State: Various
Permissible Waste Codes: D001 (OX), D002-8; D0011-12; ListedLP06C765,00032,500LBS$0.00$0.0032,500LBS$0.00$0.00
LP07Lab Packs/Loose Packs, Reactive Metals, Wet/Dry, includes Broken Sodium Lamps, MRE heaters, E-cigarettes and associated components and residues. Special Packaging May Be Required.

Physical State: Various Permissible Waste Codes:D001, D003-8, D010-11, Listed

LP07C76633LBS$0.00$0.0033LBS$0.00$0.00
LP09Lab Packs/Loose Packs, Toxic Metals.

Physical State: Various

Permissible Waste Codes: D004-8, D010-11, Listed Inorganics.LP09C713,0006,500LBS$0.00$0.006,500LBS$0.00$0.00
LP10Lab Packs/Loose Packs, Toxic Organics, for mandatory RCRA incineration.

Physical State: Various

Permissible Waste Codes: D004-8, D011-43, ListedLP10C72,6181,309LBS$0.00$0.001,309LBS$0.00$0.00
LP11Lab Packs/Loose Packs, Toxic, Acutely Hazardous, P-Listed, for mandatory RCRA incineration. Includes pharmaceuticals. May be packaged with U-Listed waste.

Physical State: Various

Permissible Waste Codes: D004-8, D010-43, P-Listed, U-ListedLP11C7475238LBS$0.00$0.00238LBS$0.00$0.00
LP12Lab Packs/Loose Packs, Toxic, U-Listed, including pharmaceuticals, for mandatory RCRA incineration.

Physical State: Various

Permissible Waste Codes: D004-8, D010-43, U-ListedLP12C72,3451,173LBS$0.00$0.001,173LBS$0.00$0.00
LP14Loose-Packed Paints and Paint-Related Materials, Primarily Oil/Petroleum-Based, >7,000 BTU/Lb, No Isocyanates. May contain <50% water-based paints. Formerly CLIN FL14.

Physical State: Various

Permissible Waste Codes: D001 (IGN), D004-43, ListedLP14C750,00025,000LBS$0.00$0.0025,000LBS$0.00$0.00
LP15Loose-Packed Paints and Paint-Related Materials, Water-Based/Latex, Non-RCRA, for solidification and disposal at a RCRA Subtitle D landfill, or equivalent. Formerly CLIN NR06. Physical State: Various Permissible Waste Codes: N/A.LP15C767,50033,750LBS$0.00$0.0033,750LBS$0.00$0.00
LP77Lab Packs/Loose Packs, Pesticides, Managed as UW per 40 CFR 273.3.

Physical State: Various

Permissible Waste Codes: UW.LP77C711457LBS$0.00$0.0057LBS$0.00$0.00
LP78Lab Packs/Loose Packs, Non-RCRA, State and Non-State Regulated, including pharmaceuticals, for mandatory RCRA Incineration. CD required. Physical State: Various
Permissible Waste Codes: N/ALP78C717,0438,522LBS$0.00$0.008,522LBS$0.00$0.00
LP79Lab Packs/Loose Packs, Miscellaneous laboratory-related wastes including preserved specimens, microscope slides, etc. No infectious or biohazardous wastes. May require a Non-Biohazardous or Non-Infectious Certificate.

Physical State: Various

Permissible Waste Codes: D001-2, D004-8, D010-43, ListedLP79C73,0001,500LBS$0.00$0.001,500LBS$0.00$0.00
Base
CLINNon-RCRA • State-Regulated • Non-State-RegulatedPBCEst. QtyEst. QtyU/MPriceExtended PriceEst. QtyU/MPriceExtended Price
NR01Non-RCRA Solids/Debris, for direct disposal at a RCRA Subtitle D landfill, or equivalent. Passes paint filter test. No asbestos. May include drained/dry non-PCB transformers, ballasts, capacitors, and related equipment.

Physical State: Solid

Permissible Waste Codes: N/A.NR01C7585,000292,500LBS$0.00$0.00292,500LBS$0.00$0.00
NR02Non-RCRA Solids/Debris with Asbestos, for direct disposal at a TSCA/RCRA Subtitle D landfill, or equivalent. Passes paint filter test. Special packaging may be required.

Physical State: Solid

Permissible Waste Codes: N/A.NR02C718,8779,439LBS$0.00$0.009,439LBS$0.00$0.00
NR03Non-RCRA Liquids, Water-Based, pumpable. NR03B5 must meet acceptance criteria for wastewater treatment (WWT) and discharge to POTW, per Section 3.29.

Physical State: Liquid

Permissible Waste Codes: N/A.NR03C71,250,000625,000LBS$0.00$0.00625,000LBS$0.00$0.00
NR04Non-RCRA Liquids, Organic-Based, pumpable, primarily consisting of wastes containing hydrocarbons. Physical State: Liquid Permissable Waste Codes: N/ANR04C7550,500275,250LBS$0.00$0.00275,250LBS$0.00$0.00
NR05Non-RCRA Liquids/Sludges/Solids/Debris, requiring solidification prior to disposal at a RCRA Subtitle D landfill, or equivalent. Includes bulk liquids not meeting acceptance criteria for wastewater treatment (WWT). May include non-PCB oil-filled transformers, ballasts, capacitors and related equipment.

Physical State: Various

Permissible Waste Codes: N/A.NR05C7625,000312,500LBS$0.00$0.00312,500LBS$0.00$0.00
NR07Non-RCRA Pharmaceuticals, prescription and non-prescription, for thermal destruction. No DEA-restricted meds. CD required.

Physical State: Various

Permissible Waste Codes: N/A.NR07C68543EA$0.00$0.0043EA$0.00$0.00
NR08Non-RCRA Empty Containers Meeting EPA "RCRA-Empty" Definition, Metal Only, Intact, for Contractor's choice of Recycle or Disposal. Physical State: Solid
Permissible Waste Codes: N/A.NR09C710050LBS$0.00$0.0050LBS$0.00$0.00
NR77Non-RCRA Blast Media Physical State: Solid
Permissible Waste Codes: N/A.NR77C716,500,0008,250,000LBS$0.00$0.008,250,000LBS$0.00$0.00
NR93Non-RCRA AFFF Concentrate Liquids for RCRA Incineration, pumpable, unused or >10% AFFF product by volume. CD required.

Physical State: Liquid.

Permissible Waste Codes: N/A.NR93C73,0001,500LBS$0.00$0.001,500LBS$0.00$0.00
NR94Non-RCRA AFFF Rinsates and other impacted waters for RCRA Incineration, Pumpable, Used or >90% water by volume. Bulk removals may be from storage tanks, containment, storm sewer, ground and surface waters. CD required.

Physical State: Liquid.

Permissible Waste Codes: N/A.NR94C7509255LBS$0.00$0.00255LBS$0.00$0.00
Base
CLINPolychlorinated Biphenyls (PCBs)PBCEst. QtyEst. QtyU/MPriceExtended PriceEst. QtyU/MPriceExtended Price
PC01PCB wastes containing or contaminated with a ≥50 ppm PCB Source (≥5 ppm in CA), RCRA or Non-RCRA, e.g., fluids, soil, sludge, debris, leaking capacitors. CD required.

Physical State: Various

Permissible Waste Codes: D001-43, Listed.PC01C81,059530KG$0.00$0.00530KG$0.00$0.00
PC02PCB Mineral Oil from Transformers, <50 ppm PCBs (<5 ppm in CA), Non-RCRA.

Physical State: Liquid

Permissible Waste Codes: N/A.PC02C83,0391,520KG$0.00$0.001,520KG$0.00$0.00
PC06PCB Oil-Filled Capacitors/Ballasts/Equipment other than Transformers, ≥50 ppm PCBs (≥5 ppm in CA), Non-RCRA, CD or Cert of Recycling required.

Physical State: Various

Permissible Waste Codes: N/A.PC06C87,0003,500KG$0.00$0.003,500KG$0.00$0.00
PC07PCB Oil-Filled Transformers, <50 ppm PCBs (<5 ppm in CA), Non-RCRA.

Physical State: Various

Permissible Waste Codes: N/A.PC07C83,8711,936KG$0.00$0.001,936KG$0.00$0.00
PC09PCB Solids/Debris Contaminated with <50 ppm Source (<5 ppm in CA), e.g., soil, transformer carcasses, drained equipment, ballasts, rags, PPE, empty containers. No Free Liquids. Non-RCRA.

Physical State: Solid

Permissible Waste Codes: N/A.PC09C86,5003,250KG$0.00$0.003,250KG$0.00$0.00
PC10PCB Solids/Debris Contaminated with ≥50 ppm Source (≥5 ppm in CA), e.g., soil, transformer carcasses, drained equipment, ballasts, rags, PPE, empty containers. No Free Liquids. Non-RCRA. CD or Cert of Recycling required.

Physical State: Solid

Permissible Waste Codes: N/A.PC10C81,916958KG$0.00$0.00958KG$0.00$0.00
PC11PCB and Non-PCB Related ballasts and other devices containing <50 ppm (<5 ppm in CA) for Mandatory Recycling of recyclable components. Cert of Recycling required. Physical State: Various Permissible Waste Codes:N/A NAVY Required.PC11C800KG$0.00$0.000KG$0.00$0.00
PC12PCB Related ballasts and other devices containing ≥50 ppm (≥5 ppm in CA) for Mandatory Recycling of recyclable components. Cert of Recycling required. Physical State: Various Permissible Waste Codes:N/A NAVY Required.PC12C800KG$0.00$0.000KG$0.00$0.00
Base
CLINAFFF and Other PFAS-Related WastesPBCEst. QtyEst. QtyU/MPriceExtended PriceEst. QtyU/MPriceExtended Price
PF01AFFF and other PFAS-related Liquids/Waters, Non-RCRA, <1.0 ppm PFAS, for treatment and disposal at RCRA Subtitle C Landfill or equivalent. <10% suspended solids, pumpable if bulk. Includes AFFF Rinsates. CD Required.PF01C71,800900LBS$0.00$0.00900LBS$0.00$0.00
PF03AFFF and other PFAS-related Liquids/Waters, Non-RCRA, >100 ppm PFAS, for treatment and disposal at RCRA Subtitle C Landfill or equivalent. <10% suspended solids, pumpable if bulk. Includes AFFF Rinsates & Concentrates. CD Required.PF03C71,800900LBS$0.00$0.00900LBS$0.00$0.00
Base
CLINMandatory Recycling • RecoveryPBCEst. QtyEst. QtyU/MPriceExtended PriceEst. QtyU/MPriceExtended Price
RE02Lamps, Fluorescent, Crushed/Broken, may contain filters.

Physical State: Solid

Permissible Waste Codes: Universal Waste, D004-11.RE02C7742371LBS$0.00$0.00371LBS$0.00$0.00
RE07Mercury, High, COD Vials, Nessler's Reagent, Chemicals and Residues, Hg >260 mg/Kg.

Physical State: Various

Permissible Waste Codes: Universal Waste, D002, D004-11.RE07C76935LBS$0.00$0.0035LBS$0.00$0.00
RE08Mercury, High, Dental Amalgams, Debris & Residues, Hg >260 mg/Kg.

Physical State: Various

Permissible Waste Codes: Universal Waste, D002, D004-11.RE08C73518LBS$0.00$0.0018LBS$0.00$0.00
RE09Mercury, High, Liquid Mercury/Devices, Debris & Residues, Hg >260 mg/Kg.

Physical State: Various

Permissible Waste Codes: Universal Waste, D004-11.RE09C7158LBS$0.00$0.008LBS$0.00$0.00
RE10Antifreeze, used and unused, for energy recovery (recycling, fuels blending). Note: RE10ME refers to 55-gal drums (Min. 30 EA/Task Order) bulked onsite, removed, leaving empty drums with Generator. Physical State: Liquid Permissible Waste Codes: Universal Waste, D004-11.RE10C760,00030,000LBS$0.00$0.0030,000LBS$0.00$0.00
RE11Used Oil, <10% Water, <1,000 ppm total organic halides (TOX), for energy recovery (recycling, fuels blending). Note: RE11ME refers to 55-gal drums (Min. 30 EA/Task Order) bulked onsite, removed, leaving empty drums with Generator. Physical State: Liquid Permissible Waste Codes: Universal Waste, D004-11.RE11C775,00037,500LBS$0.00$0.0037,500LBS$0.00$0.00
RE14Lead Articles and Spent Ammunitions Meeting Specs for Recovery.

Physical State: Solid

Permissible Waste Codes: Universal Waste, D004-11.RE14C7300150LBS$0.00$0.00150LBS$0.00$0.00
RE15Non-PCB Ballasts, Capacitors, Equipment for Recycling. Drained and Undrained. Non-TSCA, Non-RCRA.

Physical State: Various.

Permissible Waste Codes: N/A.RE15C7200100LBS$0.00$0.00100LBS$0.00$0.00
RE76Lamps, includes but not limited to: U-Bent, Circulars, Linear Fluorescent, CFL, Mercury/Mercury Vapor, Halogen, High Intesity Discharge, (HID), Light Emitting Diode (LED), Metal Halide and Metal Hydride, Sodium. Includes dunnage. Physical State: Solid Permissible Waste Codes: Universal Waste, D004-D011.RE76C776,00038,000LBS$0.00$0.0038,000LBS$0.00$0.00
Base
CLINReactivesPBCEst. QtyEst. QtyU/MPriceExtended PriceEst. QtyU/MPriceExtended Price
RX01Aerosols, Foaming, Isocyanates or other reactives.

Physical State: Various Permissible Waste Codes: Universal Waste, D004-D011.

RX01C7750375LBS$0.00$0.00375LBS$0.00$0.00
RX09Reactive Metals, Debris. Air/Water Reactive. Shipped under oil and/or other special packaging may be required. Physical State: Solid Permissible Waste Codes: D001, D003, D004-11, Listed.RX09C713065LBS$0.00$0.0065LBS$0.00$0.00
RX97Reactive, Ignitable, and Toxic Liquid for RCRA Incineration. Contains Water, Mineral Spirits, Motor Oil, <1% Cyanide, <1% Alcohol, <1% Total RCRA Metals.

Physical State: Liquid

Permissible Waste Codes: D001 -11, Listed.RX97C775,00037,500LBS$0.00$0.0037,500LBS$0.00$0.00
RX98OBA Canisters, EEBDs and Oxygen Candles, Potentially Reactive, Spent and/or Unspent. Special packaging may be required. Physical State: Solid Permissible Waste Codes: D001, D003, D004-11.RX98C75025LBS$0.00$0.0025LBS$0.00$0.00
Base
CLINToxicsPBCEst. QtyEst. QtyU/MPriceExtended PriceEst. QtyU/MPriceExtended Price
TX06Debris, Organic Constituents. >50% Debris by volume, >60 mm (~2.5") particle size. Total VOCs <500 ppm. No free liquids unless incidental rainwater or condensation (see TX20). May include inorganic Waste Code(s) and/or RCRA hazardous asbestos.

Physical State: Debris

Permissible Waste Codes: D004-11, Listed Inorganics.TX06C7175,00087,500LBS$0.00$0.0087,500LBS$0.00$0.00
TX07Debris, Organic Constituents. >50% Debris by volume, >60 mm (~2.5") particle size. Total VOCs <500 ppm. No free liquids unless incidental rainwater or condensation (see TX20). May include inorganic Waste Code(s) and/or RCRA hazardous asbestos. Physical State: Debris
Permissible Waste Codes: D004-43, Listed, but no F020-32TX07C74,3302,165LBS$0.00$0.002,165LBS$0.00$0.00
TX12Metals-Bearing Liquids, Low, <1% TCLP Metals, Total Cr+6 <100 ppm, Total Hg <260 ppm, pumpable if bulk. Characteristic only.

Physical State: Liquid

Permissible Waste Codes: D004-11.TX12C775,00037,500LBS$0.00$0.0037,500LBS$0.00$0.00
TX16Metals-Bearing Solids/Sludges/Some Free Liquids, Low (<1%) TCLP Metals, Total Cr+6 <100 ppm, Total Hg <260 ppm. Characteristic only.

Physical State: Various

Permissible Waste Codes: D004-11.TX16C764,50032,250LBS$0.00$0.0032,250LBS$0.00$0.00
TX24Organic Solvents, Technical Grade, pure or mixed solutions, with or without water and/or metals, pumpable if bulk, Flashpoint ≥140°F.

Physical State: Liquid

Permissible Waste Codes: D004-43, Listed.TX24C714,9117,456LBS$0.00$0.007,456LBS$0.00$0.00
TX98Military Items, Demil-required, RCRA Toxic, e.g., CDE Kits, Filters, PPE, etc. for Conventional RCRA Treatment and Disposal. CD required.

Physical State: Various Permissible Waste Codes: D004-43, Listed.

TX98C719296LBS$0.00$0.0096LBS$0.00$0.00
TX99Military Submarine Tiles, Demil-required via RCRA Incineration. For use even when no toxic Waste Codes apply. Requires direct shipment to TSDF. CD required. See Section 2.7.1.

Physical State: Solid Permissible Waste Codes: D004-11. TX99C7 300,000 150,000 LBS $0.00 $0.00 150,000 LBS $0.00 $0.00

Master CLIN Catalog_20210312

ADVISORY: The following is a Disposal and Recycling Master CLIN Catalog of DLA's Profile-Based CLINs (PBCs), CLIN suffixes, descriptions, physical states, and permissible EPA Waste Codes. Contractors and Government personnel are advised that these CLINs as described herein are only available for new contracts and modifications to existing contracts. These descriptions do NOT supersede descriptions as written in existing contracts where these CLINs already appear in the Price Schedule. CLIN descriptions are subject to change. Information contained herein is accurate as of the date of publication.
Base
CLINPermissible
CLIN Suffix(es)Profile-Based CLINs (PBCs)

Waste Description per Waste Profile Sheet

Date of Publication: March 12, 2021Physical
StatePermissible

EPA Waste Codes (UW = Universal Waste)

Batteries for Recycle • Disposal
BA01C7Alkaline Batteries, for Contractor's choice of recycling or disposal.VariousUW, D002, D004-11
BA02C7Calcium Chromate (CaCrO4) Thermal Batteries, Intact & Deactivated, for Contractor's choice of recycling or disposal.SolidUW, D001 (OX), D002-11
BA03C7Carbon-Zinc (CZn) Batteries, for Contractor's choice of recycling or disposal.SolidUW, D002, D004-11
BA04C7Lead Acid Batteries, Wet, Dry, or Gel Pack, for mandatory recycling.VariousUW, D002, D004-11
BA05C7Lithium Ion (Li-Ion) Batteries, for mandatory recycling.SolidUW, D002-11
BA06C7Lithium Iron Disulfide (Li2FeS2) Thermal Batteries, including fully discharged Lithium Alloy Thermal Batteries, for Contractor's choice of recycling or disposal.SolidUW, D002-11
BA07C7Lithium Manganese (LiMn and Oxides thereof) Batteries, for Contractor's choice of recycling or disposal.SolidUW, D002-11
BA08C7Lithium Sulfur Dioxide (LiSO2) Batteries, for Contractor's choice of recycling or disposal.SolidUW, D002-11
BA09C7Lithium Thionyl Chloride (LiSCl) Batteries, for Contractor's choice of recycling or disposal.SolidUW, D002-11
BA10C7Lithium Batteries, Mixed Types, deactivated if applicable, for Contractor's choice of recycling or disposal.SolidUW, D002-11
BA11C7Magnesium (Mg) Batteries, for Contractor's choice of recycling or disposal.SolidUW, D002, D004-11
BA12C7Mercury (Hg) Batteries, for mandatory recycling.SolidUW, D002, D004-11
BA13C7Nickel Metal Hydride (NiMh) Batteries, Wet and Dry, for mandatory recycling.VariousUW, D002, D004-11
BA14C7Nickel-Cadmium (NiCd) Batteries, Wet and Dry, for mandatory recycling.VariousUW, D002, D004-11
BA15C7Silver-Zinc (AgZn) and Zinc Silver Oxide (ZnAgO) Batteries, for mandatory recycling.SolidUW, D002, D004-11
BA16C7Zinc Air Batteries, fully-discharged/deactivated when required by TSDF/Recycler, for Contractor's choice of recycling or disposal.SolidUW, D002, D004-11
BA77C7Mixed Alkaline, Carbon-Zinc, Nickel-Metal-Hydride, & Titanium Batteries, for Contractor's choice of recycling or disposal.SolidUW
BA78ReservedReserved
BA79C7Lithium Batteries, Mixed Types, including Lithium Aluminum Sulfide Thermal, deactivated if applicable, for Contractor's choice of recycling or disposal.SolidUW, D002-11
BA97C7Alkaline Batteries, managed as Universal Waste (UW) for mandatory recycling.SolidUW
BA98ReservedReserved
BA99C7Lead Acid Batteries, Demil-required. Cert of Recycling required.SolidUW, D002, D004-11
Corrosives
CS01C1-C6, T1-T3, B5Corrosive Acids, Inorganic other than HF and HNO3, <50% in Water, Non-Fuming, <1% Total Metals, Cr+6 <100 ppm.LiquidD002, D004-11, Listed Inorganics
CS02C1-C6, T1-T3, B5Corrosive Acids, Inorganic other than HF and HNO3, <50% in Water, Non-Fuming, >1% Total Metals, Cr+6 <100 ppm.LiquidD002, D004-11, Listed Inorganics
CS03C1-C6, T1-T3, B5Corrosive Acids, Inorganic other than HF and HNO3, Concentrated, <1% Total Metals, Cr+6 <100 ppm.LiquidD002, D004-11, Listed Inorganics
CS04C1-C6, T1-T3, B1-B6Corrosive Acids, Chromic (H2CrO4), <1% Cr+6, Characteristic Liquids, Solids, Sludges, Debris.VariousD001 (OX), D002, D004-11
CS05C1-C6, T1-T3, B1-B6Corrosive Acids, Chromic (H2CrO4), 1-10% Cr+6, Characteristic Liquids, Solids, Sludges, Debris.VariousD001 (OX), D002, D004-11
CS06C1-C6, T1-T3, B1-B6Corrosive Acids, Chromic (H2CrO4), >10% Cr+6, Characteristic Liquids, Solids, Sludges, Debris.VariousD001 (OX), D002, D004-11
CS07C1-C6, T1-T3, B1-B6Corrosive Acids, Chromic (H2CrO4), >100 ppm Cr+6, Listed Liquids, Solids, Sludges, Debris.VariousD001 (OX), D002, D004-11, F-Listed, U032
CS08C1-C6, T1-T3, B5Corrosive Acids, Non-Fuming, Hydrofluoric (HF) <40% and/or Nitric (HNO3), <25% in Water.LiquidD001 (OX), D002, D004-11, Listed Inorganics
CS09C1-C6, T1-T3, B5Corrosive Acids, Fuming, Hydrofluoric (HF) >40% and/or Nitric (HNO3), ≥25% in Water, may include Red Fuming Nitric Acid (RFNA).LiquidD001 (OX), D002, D004-11, Listed Inorganics
CS10C1-C6, T1-T3, B5Corrosive Alkalines, Inorganic, <50% in Water, <1% Total Metals, Cr+6 <100 ppm, No Ammonia/Amines.LiquidD002, D004-11, Listed Inorganics
CS11C1-C6, T1-T3, B5Corrosive Alkalines, Inorganic, <50% in Water, >1% Total Metals, Cr+6 <100 ppm, No Ammonia/Amines.LiquidD002, D004-11, Listed Inorganics
CS12C1-C6, T1-T3, B1-B6Corrosive Ammonia/Amines, Organic/Inorganic, Liquids/Sludges/Solids/Debris, Flashpoint ≥140◦F.VariousD002, D004-43, Listed
CS13C1-C6, T1-T3, B1-B6Corrosive Organic Acids or Bases, Liquids/Sludges/Solids/Debris, No Ammonia/Amines, Flashpoint ≥140◦F.VariousD002, D004-43, Listed
CS14C1-C6, T1-T3, B1-B6Corrosive Inorganic Acids or Bases with Debris and Free Liquids, No Ammonia/Amines, Non-Flammable, including broken lead acid batteries.VariousD002, D004-11, Listed
CS15C7Corrosive Aerosols, Non-Ignitable and Non-Reactive, even when managed as UW.VariousUW, D002, D004-11, Listed
CS99C1-C7, B1-B4, B6Military Items, Demil-required, Corrosive Solids/Liquids/Debris, e.g., CDE Kits, Vials, Filters, PPE, etc. for Conventional RCRA Treatment and Disposal. CD Required.VariousD002, D004-11, Listed
Compressed Gas Cylinders (CGC) • Cartridges • Canisters • Vessels

Lecture (ME) = 3"x 12" • Small (M1) = 4"x 24" • Medium (M2) = 12"x 36" • Large (M3) = 16"x 56"

CY01ME, M1-M3Category 1 Compressed Gas Cylinders (CGC), Cartridges, Canisters and Vessels. Refer to CGC Cross-Reference Table for list of gases.Comp. GasAs applicable to contained gas or mixed gases
CY02ME, M1-M6Category 2 Compressed Gas Cylinders (CGC), Cartridges, Canisters and Vessels. Refer to CGC Cross-Reference Table for list of gases.Comp. GasAs applicable to contained gas or mixed gases
CY03ME, M1-M3Category 3 Compressed Gas Cylinders (CGC), Cartridges, Canisters and Vessels. Refer to CGC Cross-Reference Table for list of gases.Comp. GasAs applicable to contained gas or mixed gases
CY04ME, M1-M3Category 4 Compressed Gas Cylinders (CGC), Cartridges, Canisters and Vessels. Refer to CGC Cross-Reference Table for list of gases.Comp. GasAs applicable to contained gas or mixed gases
CY05ME, M1-M3Category 5 Compressed Gas Cylinders (CGC), Cartridges, Canisters and Vessels. Refer to CGC Cross-Reference Table for list of gases.Comp. GasAs applicable to contained gas or mixed gases
CY06ME, M1-M6Category 6 Compressed Gas Cylinders (CGC), Cartridges, Canisters and Vessels. Refer to CGC Cross-Reference Table for list of gases.Comp. GasAs applicable to contained gas or mixed gases
CY07ME, M1-M3Category 7 Compressed Gas Cylinders (CGC), Cartridges, Canisters and Vessels. Refer to CGC Cross-Reference Table for list of gases.Comp. GasAs applicable to contained gas or mixed gases
CY08ME, M1-M6Category 8 Compressed Gas Cylinders (CGC), Cartridges, Canisters and Vessels. Refer to CGC Cross-Reference Table for list of gases.Comp. GasAs applicable to contained gas or mixed gases
CY09ME, M1-M3Cylinders, Acetylene, Containing Asbestos, for Purge and Landfill.Comp. GasD001
CY10ME, M1-M3Cylinders, Acetylene, No Asbestos, for Recycle/Reuse.Comp. GasD001
CY11MECylinders, Propane, 20-Lb "Grill Size", for Disposal, Recycle, or Reuse. Typically 13" x 17". "ME" = 1 EA Grill-Size Cylinder.Comp. GasD001
CY12MECylinders, Flammable, AVGAS, Ether Gas/Diesel Starting, for Disposal or Recycle. Diameter up to 3", Length up to 12". "ME" = 1 EA Cylinder.Comp. GasD001
CY13MECartridges, Inert Gas, for Disposal/Recycle/Reuse. Diameter up to 1", Length up to 6". "ME" = 1 EA Cartridge.Comp. GasN/A
Flammables • Combustibles • Ignitables
FL01C7Aerosols, Flammable/Combustible/Ignitable, non-foaming. No isocyanates, reactives, or corrosives, even when managed as UW.VariousUW, D001 (IGN), D004-43, Listed
FL02C1-C6, B1-B4, B6Flammable Debris contaminated with common solvents, shreddable, no free liquids, no large metal, rock, or masonry components.SolidD001, D004-43, Listed
FL03C1-C6, T1-T3, B1-B6Flammable Liquids/Solids/Sludges/Debris, e.g., tank sludge, lubricants, adhesives, miscellaneous debris, non-reactive paint waste with isocyanates, primarily consists of incinerable, non-fuels-blendable materials. Use LP03 for loose packs.VariousD001-2, D004-43, Listed
FL04C1-C7, T1-T3, B1-B6Flammable Corrosive Liquids/Solids/Sludges/Debris/Aerosols. Use LP03 for loose packs other than aerosols. FL04C7 for use with flammable corrosive aerosols only.VariousUW (Aerosols Only), D001 (IGN), D002, D004-43, Listed.
FL05C1-C6, T1-T3, B5Flammable Liquids, Pumpable, Fuels Blendable, Rich, >7,000 BTU/Lb, <5% total chlorine, no isocyanates.LiquidD001 (IGN), D004-43, Listed
FL06C1-C6, T1-T3, B5Flammable Liquids, Pumpable, Fuels Blendable, Lean, 2,500-7,000 BTU/Lb, <5% total chlorine, no isocyanates.LiquidD001 (IGN), D004-43, Listed
FL07C1-C6, T1-T3, B5Flammable Liquids, Pumpable, Fuels Blendable, Lean to Rich, >2,500 BTU/Lb, 5-10% total chlorine, no isocyanates.LiquidD001 (IGN), D004-43, Listed
FL08C1-C5, T1-T3Flammable Resuspendable Solids/Sludges, Fuels Blendable, Rich, >7,000 BTU/Lb, <5% total chlorine, no isocyanates.VariousD001 (IGN), D004-43, Listed
FL09C1-C5, T1-T3Flammable Resuspendable Solids/Sludges, Fuels Blendable, Lean, 2,500-7,000 BTU/Lb, <5% total chlorine, no isocyanates.VariousD001 (IGN), D004-43, Listed
FL10C1-C5, T1-T3Flammable Resuspendable Solids/Sludges, Fuels Blendable, Lean to Rich, >2,500 BTU/Lb, 5-10% total chlorine, no isocyanates.VariousD001 (IGN), D004-43, Listed
FL11C1-C6, T1-T3, B5Flammable Liquids, Highly Chlorinated (>10%), Pumpable, Solvents, Herbicides, and Pesticides. No PCBs, Dioxins, Furans, or Precursors.LiquidUW (Pesticides Only), D001 (IGN), D004-43, Listed.
FL12C1-C6, B1-B4Flammable Solids/Sludges, Highly Chlorinated (>10%), Solvents, Herbicides, and Pesticides. No PCBs, Dioxins, Furans, or Precursors.VariousUW (Pesticides Only), D001 (IGN), D004-43, Listed.
FL13C1-C6, T1-T3, B1-B6Oxidizers, Non-Reactive, Liquids/Sludges/Solids/Debris, other than chromic acid (see Corrosives).VariousD001 (OX), D002, D004-43, Listed
FL14ObsoleteRefer to LP14.
FL15C1-C5, T1-T3, B5Water Contaminated with Common Solvents, pumpable if bulk, <2,500 BTU/Lb.LiquidD001 (IGN), D004-43, Listed
FL70C7, B9Unsymmetrical Dimethylhydrazine (UDMH) liquid propellant, pumpable, for destruction and disposal only. Gov't transportation provided. CD Required.

DOT: Haz Class 6.1, (3,8), PG I, Poison Inhalation Zone B.

LiquidD001-D002, U098
FL71C7, B9Dinitrogen Tetroxide (N2O4) liquid propellant, pumpable, low-boiling-point liquid, for destruction and disposal only. Gov't transportation provided. CD Required.

DOT: Haz Class 2.3 (5.1, 8), Poison Inhalation Zone A.

LiquidD001-D002, P078
FL72MEFlammable Solids/Sludges/Liquids under pressure. CLIN Suffix "ME" refers to one container under pressure no larger than 16" x 54".VariousD001 (IGN)
FL73C1-C5, T1-T3, B5Flammable Liquids carrying Utah State Waste Code(s), for mandatory incineration. Includes P- and U-Codes. CD required.LiquidD001, D004-D043, Listed
FL74C1-C6, B1-B4, B6Flammable Solids/Sludges/Debris carrying Utah State Waste Code(s), for mandatory incineration. Includes P- and U-Codes. CD required.VariousD001, D004-D043, Listed
FL75C7Flammable Aerosols, paints and paint-related materials, non-foaming, no isocyanates, Texas UW.VariousUW
FL76C1-C5, T1-T3, B5Flammable Liquids, paints and paint-related materials, pumpable, lean to rich, >2,500 BTU/Lb, 5-10% total chlorine, Texas UW.LiquidUW
FL77C1-C5, T1-T3, B5Flammable Liquids, paints and paint-related materials, pumpable, rich, >7,000 BTU/Lb, <5% total chlorine, Texas UW.LiquidUW
FL78C1-C5, T1-T3, B5Flammable Liquids, paints and paint-related wastes, pumpable, lean, 2,500-7,000 BTU/Lb, <5% total chlorine, Texas UW.LiquidUW
FL79C1-C6, B1-B4, B6Flammable Solids/Sludges/Debris, paints and paint-related wastes, FLP <140° F, Texas UW.VariousUW
FL99C1-C7, B1-B4, B6Military Items, Demil-required, Flammable Solids/Liquids/Debris, e.g., CDE Kits, Vials, Filters, PPE, etc. for conventional RCRA treatment, disposal. CD required.VariousD001 (IGN), D002, D004-43, Listed
Lab Packs • Loose Packs
LP01C1-C6Lab Packs/Loose Packs, Corrosives, Organic or Inorganic, Liquids or Solids, Non-Flammable.VariousD002, D004-8, D010-11, Listed
LP02C1-C5, M1-M2Lab Packs/Loose Packs, Mercury, Elemental Liquid, for mandatory recycling in U.S.VariousD004-11, Listed Inorganics
LP03C1-C6Lap Packs/Loose Packs, Flammables and Flammable Corrosives, other than paints and paint-related materials eligible for LP14, for mandatory RCRA incineration.VariousD001-2, D004-8, D010-43, Listed
LP04C1-C6Lab Packs/Loose Packs, Non-RCRA, State and Non-State Regulated, other than paints eligible for LP15, includes pharmaceuticals.VariousN/A
LP05C1-C6Lab Packs/Loose Packs, Non-Reactive Oxidizers, for mandatory RCRA incineration.VariousD001 (OX), D002, D004-8, D010-11, Listed
LP06C1-C6Lab Packs/Loose Packs, Reactive Oxidizers, including Organic Peroxides, for mandatory RCRA incineration. Special packaging may be required.VariousD001 (OX), D002-8, D011-12, Listed
LP07C1-C6Lab Packs/Loose Packs, Reactive Metals, Wet/Dry, includes Broken Sodium Lamps, MRE heaters, E-cigarettes and associated components and residues. Special packaging may be required.VariousD001, D003-8, D010-11, Listed
LP08C1-C6Lab Packs/Loose Packs, Reactives, Non-Metals, Non-Oxidizing, for mandatory RCRA incineration. Special packaging may be required.VariousD001-8, D010-43, Listed
LP09C1-C6Lab Packs/Loose Packs, Toxic Metals.VariousD004-8, D010-11, Listed Inorganics
LP10C1-C6Lab Packs/Loose Packs, Toxic Organics, for mandatory RCRA incineration.VariousD004-8, D011-43, Listed
LP11C1-C6Lab Packs/Loose Packs, Toxic, Acutely Hazardous, P-Listed, for mandatory RCRA incineration. Includes pharmaceuticals. May be packaged with U-Listed waste.VariousD004-8, D010-43, P-Listed, U-Listed
LP12C1-C6Lab Packs/Loose Packs, Toxic, U-Listed, including pharmaceuticals, for mandatory RCRA incineration.VariousD004-8, D010-43, U-Listed
LP13C1-C6Lab Packs/Loose Packs, Pesticides, for mandatory RCRA incineration. See CLIN LP77 for management as UW.VariousD004-8, D010-43, U-Listed
LP14C1-C6Loose-Packed Paints and Paint-Related Materials, Primarily Oil/Petroleum-Based, >7,000 BTU/Lb, No Isocyanates. May contain <50% water-based paints. Formerly CLIN FL14.VariousD001 (IGN), D004-43, Listed
LP15C1-C6Loose-Packed Paints and Paint-Related Materials, Water-Based/Latex, Non-RCRA, for solidification and disposal at a RCRA Subtitle D landfill, or equivalent. Formerly CLIN NR06.VariousN/A
LP77C1-C6Lab Packs/Loose Packs, Pesticides, Managed as UW per 40 CFR 273.3.VariousUW
LP78C1-C6Lab Packs/Loose Packs, Non-RCRA, State and Non-State Regulated, including pharmaceuticals, for mandatory RCRA Incineration. CD required.VariousN/A
LP79C1-C5Lab Packs/Loose Packs, Miscellaneous laboratory-related wastes including preserved specimens, microscope slides, etc. No infectious or biohazardous wastes. May require a Non-Biohazardous or Non-Infectious Certificate.VariousD001-2, D004-8, D010-43, Listed
Non-RCRA • State-Regulated • Non-State-Regulated
NR01C1-C6, B1-B4, B6Non-RCRA Solids/Debris, for direct disposal at a RCRA Subtitle D landfill, or equivalent. Passes paint filter test. No asbestos. May include drained/dry non-PCB transformers, ballasts, capacitors, and related equipment.SolidN/A
NR02C1-C6, B1-B4, B6Non-RCRA Solids/Debris with Asbestos, for direct disposal at a TSCA/RCRA Subtitle D landfill, or equivalent. Passes paint filter test. Special packaging may be required.SolidN/A
NR03C1-C6, T1-T3, B5Non-RCRA Liquids, Water-Based, pumpable. NR03B5 must meet acceptance criteria for wastewater treatment (WWT) and discharge to POTW, per Section 3.29.LiquidN/A
NR04C1-C6, T1-T3, B5Non-RCRA Liquids, Organic-Based, pumpable, primarily consisting of wastes containing hydrocarbons.LiquidN/A
NR05C1-C6, T1-T3, B1-B6Non-RCRA Liquids/Sludges/Solids/Debris, requiring solidification prior to disposal at a RCRA Subtitle D landfill, or equivalent. Includes bulk liquids not meeting acceptance criteria for wastewater treatment (WWT). May include non-PCB oil-filled transformers, ballasts, capacitors and related equipment.VariousN/A
NR06ObsoleteRefer to LP15.
NR07C1-C6Non-RCRA Pharmaceuticals, prescription and non-prescription, for thermal destruction. No DEA-restricted meds. CD required.VariousN/A
NR08C1-C5, T1-T3Non-RCRA Empty Containers Meeting EPA "RCRA-Empty" Definition, Metal Only, Intact, for Contractor's choice of Recycle or Disposal.SolidN/A
NR09C1-C5, T1-T3Non-RCRA Empty Containers Meeting EPA "RCRA-Empty" Definition, Metal and/or Plastic/Poly, crushed or damaged, for Contractor's choice of Recycle or Disposal.SolidN/A
NR10C1-C5, T1-T3Non-RCRA Empty Containers Meeting EPA "RCRA-Empty" Definition, Plastic/Poly Only, Intact, for Contractor's choice of Recycle or Disposal. Totes (T1-T3) may have metal components.SolidN/A
NR11C1-C6, B1-B4, B6Non-RCRA Combustible Solids/Debris for Waste-To-Energy (WTE) Disposal. May contain some free liquids.VariousN/A
NR12C1-C6, B1-B4, B6Non-RCRA Solids/Blast Media/Debris containing DOE-Exempt Naturally Occurring Radioactivity (NORM) measuring <2,000 pCi/g for direct disposal at a properly permitted RCRA Subtitle D or Subtitle C landfill. Generator must obtain authorization for disposal from US Army Joint Munitions Command.SolidN/A
NR79C4Non-RCRA Solids @ (Insert Location), POL-Contaminated Items, e.g., pads, rags, booms, sweepables, etc. for mandatory recycling or WTE. Contractor returns empty containers to Generator for reuse.SolidN/A
NR90C1-C6, B1-B4, B6Non-RCRA AFFF-Related Solids/Sludges/Debris for RCRA Incineration, e.g., soil, gravel, filter media, tank bladders, etc. May contain some free liquids. CD required.VariousN/A
NR93C1-C6, T1-T3, B5Non-RCRA AFFF Concentrate Liquids for RCRA Incineration, pumpable, unused or >10% AFFF product by volume. CD required.LiquidN/A
NR94C1-C5, T1-T3, B5Non-RCRA AFFF Rinsates and other impacted waters for RCRA Incineration, Pumpable, Used or >90% water by volume. Bulk removals may be from storage tanks, containment, storm sewer, ground and surface waters. CD required.LiquidN/A
NR95C1-C7, B1-B4, B6Non-Regulated Electron Tubes, Demil-Required, for direct disposal at a RCRA Subtitle D landfill, or equivalent. CD required.SolidN/A
NR96C1-C6, T1-T3, B5Non-RCRA Liquids for RCRA Incineration, pumpable. Not used for AFFF or other PFAS-related wastes. CD required.LiquidN/A
NR97C1-C6, B1-B4, B6Non-RCRA Solids/Sludges/Debris for RCRA Incineration. May contain some free liquids. Not used for AFFF or other PFAS-related wastes. CD required.VariousN/A
NR98C1-C7, B1-B4, B6Non-RCRA Military Articles, Demil-Required, e.g., boots, gloves, CDE kits, filters, masks, MOPP suits, etc. for direct disposal at a RCRA Subtitle D landfill, or equivalent. CD required. No uniforms (NR99) or submarine tiles (TX99).VariousN/A
NR99ReservedNon-RCRA Military Uniforms/Textiles, Demil-Required, for thermal destruction. CD required.SolidN/A
Polychlorinated Biphenyls (PCBs)
PC01C7-C8, B1-B4, B8PCB wastes containing or contaminated with a ≥50 ppm PCB Source (≥5 ppm in CA), RCRA or Non-RCRA, e.g., fluids, soil, sludge, debris, leaking capacitors. CD required.VariousD001-43, Listed
PC02C7-C8PCB Mineral Oil from Transformers, <50 ppm PCBs (<5 ppm in CA), Non-RCRA.LiquidN/A
PC03C7-C8PCB Mineral Oil from Transformers, 50-4,000 ppm PCBs (5-4,000 ppm in CA). Non-RCRA, CD or Cert of Recycling required.LiquidN/A
PC04C7-C8PCB Mineral Oil, Water, Other Fluids, >4,000 ppm PCBs. RCRA or Non-RCRA. CD required.LiquidD001-43, Listed
PC05C7-C8, B1-B4, B8PCB Oil-Filled Capacitors/Equipment other than Transformers, <50 ppm PCBs (<5 ppm in CA), Non-RCRA.VariousN/A
PC06C7-C8, B1-B4, B8PCB Oil-Filled Capacitors/Ballasts/Equipment other than Transformers, ≥50 ppm PCBs (≥5 ppm in CA), Non-RCRA, CD or Cert of Recycling required.VariousN/A
PC07C7-C8, B1-B4, B8PCB Oil-Filled Transformers, <50 ppm PCBs (<5 ppm in CA), Non-RCRA.VariousN/A
PC08C7-C8, B1-B4, B8PCB Oil-Filled Transformers, ≥50 ppm PCBs (≥5 ppm in CA). CD or Cert of Recycling required.VariousN/A

This is the start of the file's text. The full file is on GovTribe.